EMC VNX FAMILY - sa · PDF fileA Single Unified Application Solution ... EMC VMAX ranked #1...
Transcript of EMC VNX FAMILY - sa · PDF fileA Single Unified Application Solution ... EMC VMAX ranked #1...
1 © Copyright 2013 EMC Corporation. All rights reserved.
EMC VNX FAMILY Transforming Midrange Storage
2 © Copyright 2013 EMC Corporation. All rights reserved.
A Single Unified Application Solution
Lowest $/IO
Lowest $/GB
Fully Automated
Hybrid Array
Optimized for Virtualized Workloads
VDI Home Dir.
3 © Copyright 2013 EMC Corporation. All rights reserved.
50X Higher Cost
150X Higher Cost
Flash in the Data Center
Transaction Performance
Capacity C
ost
FLASH SSD
PCIe FLASH
3000X Better Performance
300X Better Performance
15K RPM HDD HIGH
CAPACITY HDD
4 © Copyright 2013 EMC Corporation. All rights reserved.
Adding SSDs to an old-school, HDD-based array
The Traditional Hybrid Array
Reduces cost, power, and footprint Low $/GB Controllers and software not designed/optimized for FLASH
Controller
HDDs
SSDs
5 © Copyright 2013 EMC Corporation. All rights reserved.
FLASH-Optimized Hybrid Arrays Automatically Tier Data
PERFORMANCE CAPACITY
INACTIVE DATA
ACTIVE DATA
FAST dynamically and automatically
optimizes storage pools based on actual data activity
5% FLASH 95% DISK
6 © Copyright 2013 EMC Corporation. All rights reserved.
While a little FLASH goes a long way, media cost is mostly FLASH
The FLASH 1st Storage Media Dollar
Typical FLASH 1st capacity distribution:
– 5% FLASH
– 10% 15K HDD, and
– 85% NL-HDD
Typical FLASH 1st media cost distribution:
– 68% FLASH
– 10% 15K HDD, and
– 22% NL-HDD
68%
10% 22%
Storage Media Spend
FLASH 15K HDD 7200 HDD
7 © Copyright 2013 EMC Corporation. All rights reserved.
Study Affirms EMC # 1 Deepest Integration for VMware EMC #1 For Third Consecutive Year in Wikibon Study of Integration Value Across All Categories for VMware vSphere Environments
EMC for the third year in a row the #1 storage vendor
Ranked EMC #1 as the most integrated storage for Vmware
VNX scored better than other storage vendors in the study.
VNX was #1 in 3 categories – general, block-only and file storage.
EMC VMAX ranked #1 array for Tier 1 storage.
The study ranked EMC VNX and VMAX highest for security.
Press release August 23, 2013 http://www.emc.com/about/news/press/2013/20130823-01.htm
8 © Copyright 2013 EMC Corporation. All rights reserved.
INCREASED CPU PRESSURE
0
2
4
6
8
10
12
Start Year 1 Year 2 Year 3 Year 4 Year 5
10X Every 5 Years
INCREASED CAPACITY
0
2
4
6
8
10
12
Start Year 1 Year 2 Year 3 Year 4 Year 5
10X Every 5 Years
VIRTUALIZED DATA CENTER
A powerful combination
Moore’s Law and Data Growth
DATA GROWTH
MOORE’S LAW
Midrange storage
is the
foundation of
modern
server farms
Hundreds of CPU Cores
9 © Copyright 2013 EMC Corporation. All rights reserved.
Modern systems must have multi-core software support
Today’s Reality: Multi-Core Systems
Controller A
10 Cores
10 Cores 2,000 Drives SSD or HDD
(any combination)
Controller B
10 Cores
10 Cores
11 SLIC slots SAS, 10GbE, FC,
or IB
11 SLIC slots SAS, 10GbE, FC,
or IB
40 cores
Today 32-40 cores are available in a dual controller array
10 © Copyright 2013 EMC Corporation. All rights reserved.
Dynamic Multicore Optimization
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Co
re U
tilizati
on
Core Number
Static Core Utilization
RAID I/O DRAM Cache FAST Cache Data Services Management Available
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0 1 2 3 4 5
Co
re U
tilizati
on
Core Number
Introducing MCx New Multi-Core technology to unleash greater system performance
11 © Copyright 2013 EMC Corporation. All rights reserved.
New Clean-Sheet design
Unlocking the Power of Flash
SP A SP B
32 LANES CMI
32 CPU
CORES
160 LANES
PCIE G3
1500 SSDs or
HDDs
SAS 2.0 SAS 2.0
FC, iSCSI, NFS, pNFS,
and CIFS
22 PCIE
IO SLOTS
FC, iSCSI, NFS, pNFS, and CIFS
12 © Copyright 2013 EMC Corporation. All rights reserved.
The performance of FLASH with the efficiency of tiering
The New FLASH-Optimized Hybrid Array
Takes full advantage of the low latency of FLASH FLASH-optimized software and data services Delivers progressively lower $/IOPS at scale Moves inactive data to NL-HDDs for lowest $/GB
Controller
SSDs
HDDs
13 © Copyright 2013 EMC Corporation. All rights reserved.
Lower risk with increased availability within data centers
EMC VNX Active-Active for Block
Eliminate application time-outs – No trespass
Load balancing delivers up to 2X performance – All paths are active
Available for block on Classic LUNs – Ideal for apps that need highest level of availability
and do not require advanced data services like FAST
LUN
14 © Copyright 2013 EMC Corporation. All rights reserved.
Superior firepower and capacity
EMC VNX NxM Architecture
Controller A
8 Cores
8 Cores 1,500 Drives SSD or HDD
(any combination)
Controller B
8 Cores
8 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
XBlade
6 Cores
• 80 CPU Cores • 448 GB DRAM • 586 TB FLASH • 4,395 TB HDD
(Any combination)
More FIREPOWER
NFS, CIFS, pNFS
FC, FCoE, iSCSI
15 © Copyright 2013 EMC Corporation. All rights reserved.
MCx™- Leading NFS Response Time
NFS File Serving
Vendor I
16-Node Cluster
Vendor N
8-Node Cluster
Vendor O Dual Node
Vendor D
4+4 Node Cluster
Source: www.spec.org SPECsfs2008_nfs.v3
2.6X FASTER
16 © Copyright 2013 EMC Corporation. All rights reserved.
Example: VMWare on NFS Transactional NAS Latency Improvement
VNX VNX Next Gen
IO
PS
Late
ncy
Read Latency
Write Latency
IOPS
3x IOPS
60% Faster
17 © Copyright 2013 EMC Corporation. All rights reserved.
Lower risk with online file migrations
Online File Operations
Cost
Complexity
Availability
SIMPLE From NS and VNX in 3 steps
AUTOMATED Migrates snaps and settings
TRANSPARENT Clients stay connected
Migration Challenges VNX Virtual Data Mover Solution
18 © Copyright 2013 EMC Corporation. All rights reserved.
64K 64K
64K
FAST Virtual Pool
FAST Cache
NL-HDD HDD SSD 256M
FAST Cache, FAST VP, and File and Block
Lower Capex with eMLC and better FAST VP granularity
FAST Suite for File and Block
FAST Cache
– Caches from HDD or NL-HDD tiers to FAST Cache-Optimized SSDs at page granularity of 64K
FAST VP
– Dynamically moves data between FAST VP-Optimized SSDs, HDD, and NL-HDD tiers at slice granularity of 256 MB
Deploying both together ensures maximum IO granularity
LUNs may be deployed for SAN or used for NFS or CIFS
4,096 times more granular
SAN LUNs
LUNs
NFS/CIFS NAS Volumes
19 © Copyright 2013 EMC Corporation. All rights reserved.
New VNX Block Deduplication
Lowers Flash capacity requirements by 50% or more
Deduplication at 8KB granularity
– Out of band -minimizes I/O impact
Ideal for virtual machines & virtual desktops with redundant data across multiple sources
De-dupe Engine
User Changes
Index Database
LUN
Free Pool
Read
De-dupe
Storage Pool
LUN
20 © Copyright 2013 EMC Corporation. All rights reserved.
FAST + Deduplication = Lowest $/GB
Compounded Efficiencies
86% lower cost
83% smaller footprint
50% lower cost
24 12
210
16 8
30
15
0
50
100
150
200
Monolithic FAST 5:10:85 FAST 5:10:85 + De-Dupe
Drive S
lots
Consum
ed
Compounded Efficiency Example
3TB 15K SSD
68%
10%
22%
Storage Media Spend FLASH 15K HDD 7200 HDD
21 © Copyright 2013 EMC Corporation. All rights reserved.
The Right Protection for Every Application Need
Up to 256 snaps per LUN for block and 112 snaps per file system
Maintain SLAs with application protection as a service
RPO at or close to zero with RecoverPoint Remote
DVR-like recovery to any point in time using RecoverPoint Local
Purpose-built deduplication appliances accelerate backup and recovery
The exact same information, read and write accessible at the same time, in two separate locations
22 © Copyright 2013 EMC Corporation. All rights reserved.
Lower cost with self-service protection
Application Protection with AppSync 1.5
SELF-SERVICE
Enable application owners to drive protection
SIMPLE
Protect and restore critical applications in minutes
SLA-DRIVEN
Receive alerts when SLAs are not met
SILVER
GOLD
BRONZE
Dynamic Application Protection—Optimized for Virtual Apps
EMC AppSync supports VMware, Exchange 2010 and 2013, SQL 2008 and 2012, and NFS file Shares
23 © Copyright 2013 EMC Corporation. All rights reserved.
TRADITIONAL
Must increase visibility and automation
Virtualization Amplifies Management Needs
VIRTUALIZED
10X
Automation Manual Tuning
24 © Copyright 2013 EMC Corporation. All rights reserved.
New Unisphere Management Suite
Improve Management Productivity
UNISPHERE Intuitive, task-based systems management
UNISPHERE REMOTE Manage XtremSW Cache and thousands of VNX/VNXe
VNX MONITORING & REPORTING Powerful insights and planning ahead
25 © Copyright 2013 EMC Corporation. All rights reserved.
EMC VNX Series Models
VNX5200* VNX5400 VNX5600 VNX5800 VNX7600 VNX8000
Max FAST Cache 600 GB 1 TB 2 TB 3 TB 4.2 TB 4.2 TB
Max drives 125 250 500 750 1000 1500**
Drive types Flash, SAS, NL-SAS
File System modules
X-Blades 1 or 2 1 or 2 1 or 2 2 or 3 2 to 4 2 to 8
I/O slots per X-blade 3 3 3 4 4 5
Memory per X-blade 6 GB 6 GB 12 GB 12 GB 24 GB 24 GB
Protocols CIFS, NFS, pNFS
Storage Pool
modules
Storage Processors 2 2 2 2 2 2
I/O ports per SP 2 2 2 2 2 2
I/O slots per SP 3 4 5 5 5 11
Memory per SP 16 GB 16 GB 24 GB 32 GB 64 GB 128 GB
Cores per SP 4 4 4 6 8 16
Protocols Fibre Channel, Fibre Channel over Ethernet, iSCSI
* Available Q4 2013 ** Initial support is for 1000 drives
26 © Copyright 2013 EMC Corporation. All rights reserved.
VNX-CA CONTINUOUS AVAILABILITY
NODE NODE NODE
Improved availability Zero downtime for planned and unplanned outages
and non-disruptive migrations forever
Increased asset utilization Active-active data access, load balance and extend local
functionality (VMware, Oracle RAC) over distance
27 © Copyright 2013 EMC Corporation. All rights reserved.
VNX-F
Up to 600TB FLASH
ALL F LASH VNX8000-F
VNX7600-F
1M IOPS
500K IOPS
28 © Copyright 2013 EMC Corporation. All rights reserved.
FLASH-optimized for today’s virtual cloud environments
The EMC VNX Family
SIMPLE. EFFICIENT. POWERFUL. PROTECTED.
VNX5400 VNX5600 VNX5800 VNX7600 VNX8000 VNXe3300 VNXe3150 VNX5200*
* Available Q4 2013
30 © Copyright 2013 EMC Corporation. All rights reserved.
Flash-Optimized Sub-millisecond Data Services
Inherently Balanced Linear Scale-Out Architecture
Software-Defined Non-Proprietary Hardware
XtremIO Announcement 14-nov-2013
31 © Copyright 2013 EMC Corporation. All rights reserved.
XtremIO Inline Data Reduction
Thin Provisioning & Data Reduction
savings
150 full clones (40GB each) fit
in 20GB of flash!
Remaining 192GB was
other test data
32 © Copyright 2013 EMC Corporation. All rights reserved.
Full Copy on
Ptr Ptr Ptr Ptr Ptr Ptr
Addr +4k +8k +12k +16
k +20k
A B C D
Sounds like a Free lunch!
X-Copy command
Ptr
NewAddr
Ptr
+4k
Ptr
+8k
Ptr
+12k
Ptr
+16k
Ptr
+20k
Metadata in Memory
Data on SSD
34 © Copyright 2013 EMC Corporation. All rights reserved.
VPLEX changes the status quo…
… by enabling users to:
Have the exact SAME information – Read and write accessible at the SAME time – In two separate locations
35 © Copyright 2013 EMC Corporation. All rights reserved.
Traditional Array Replication
Instance A Active Failure Domain
LUN 2P
LUN 1P
Instance B Passive Failure Domain
LUN 2P
LUN 1P
Manual Invocation
Active – Passive Data Access
Replication
Master & Slave
RPO 0
Extra Resources
Failover
Array Replication
36 © Copyright 2013 EMC Corporation. All rights reserved.
Continuous Availability During Site Failure
Distributed Virtual Volumes
SITE 2 SITE 1
ESX Stretch Cluster
SITE
DOWN