EMC Test Report for CE Certification
description
Transcript of EMC Test Report for CE Certification
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Seite 1 von 13 Page 1 of 13
Auftraggeber: Client:
PH Technical Labs 1200 Commerce Dr, Suite #112, Plano, TX 75093.
Gegenstand der Prfung: Test item:
Hot Watch
Bezeichnung: Identification:
HOT0103 Serien-Nr.: Serial No.:
Engineering Sample
Wareneingangs-Nr.: Receipt No.:
1803033379-1-1 Eingangsdatum: Date of receipt:
April 2014
Prfort: Testing location:
Refer to section: Test Facilities
Prfgrundlage: Test specification:
[Immunity] EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012 EN 61000-4-2:2009 (contact: level 2 (4kV),(Air: level 3 (8kV)) EN 61000-4-3:2006+A2:2010 ( 80 - 1000)MHz, (1.4 - 2.7)GHz, level 2 (3V/m))
Prfergebnis: Test Result:
Der Prfgegenstand entspricht oben genannter Prfgrundlage(n). The test item passed the test specification(s).
Prflaboratorium: Testing Laboratory:
TV Rheinland (India) Pvt. Ltd. Plot No. 108, West Wing, Electronics City Phase 1, Hosur Road Bangalore 560 100. India.
geprft/ tested by:
Un-Specified Written / Tested By / Inspector
Datum Name/Stellung Unterschrift Date Name/Position Signature
kontrolliert/ reviewed by:
Un-Specified Checked By / Reviewer
Datum Name/Stellung Unterschrift Date Name/Position Signature
Sonstiges / Other Aspects:
Abkrzungen: P(ass) = entspricht Prfgrundlage F(ail) = entspricht nicht Prfgrundlage N/A = nicht anwendbar N/T = nicht getestet
Abbreviations: P(ass) = passed F(ail) = failed N/A = not applicable N/T = not tested
Dieser Prfbericht bezieht sich nur auf das o.g. Prfmuster und darf ohne Genehmigung der Prfstelle nicht auszugsweise vervielfltigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Prfzeichens.
This test report relates to the a. m. test sample. Without permission of the test center this test report is not permitted to be duplicated in extracts. This test report does not entitle to carry any safety mark on this or similar products.
TV Rheinland Product Safety GmbH Am Grauen Stein D - 51105 Kln Tel.: +49 221 806-1371 Fax: +49 221 806-3909 Mail: [email protected] Web: www.tuv.com Version: 2009-07-27
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 2 von 13 Page 2 of 13
TEST SUMMARY
5.1.1 RADIATED RADIO-FREQUENCY ELECTROMAGNETIC FIELDS (RS) RESULT: PASS
5.1.2 ELECTROSTATIC DISCHARGES (ESD) RESULT: PASS
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 3 von 13 Page 3 of 13
Contents
1. GENERAL REMARKS ............................................................................................... 4
1.1 COMPLEMENTARY MATERIALS ................................................................................. 4
2. TEST SITES ............................................................................................................ 4
2.1 TEST FACILITIES ..................................................................................................... 4
2.2 LIST OF TEST AND MEASUREMENT INSTRUMENTS ...................................................... 4
3. GENERAL PRODUCT INFORMATION ........................................................................... 5
3.1 PRODUCT FUNCTION AND INTENDED USE .................................................................. 5
3.2 RATINGS AND SYSTEM DETAILS ............................................................................... 5
3.3 INDEPENDENT OPERATION MODES ........................................................................... 5
3.4 NOISE GENERATING AND NOISE SUPPRESSING PARTS .............................................. 5
3.5 SUBMITTED DOCUMENTS ......................................................................................... 5
4. TEST SET-UP AND OPERATION MODES ..................................................................... 6
4.1 PRINCIPLE OF CONFIGURATION SELECTION ............................................................... 6
4.2 PHYSICAL CONFIGURATION FOR TESTING ................................................................. 6
4.3 TEST OPERATION AND TEST SOFTWARE ................................................................... 6
4.4 SPECIAL ACCESSORIES AND AUXILIARY EQUIPMENT ................................................. 6
4.5 COUNTERMEASURES TO ACHIEVE EMC COMPLIANCE ................................................ 6
5 . TEST RESULTS I M M U N I T Y ............................................................................. 7
5.1 CONTINUOUS DISTURBANCES .................................................................................. 7 5.1.1 Radiated Radio-frequency Electromagnetic Fields (RS) ............................................................. 7 5.1.2 Electrostatic Discharges (ESD) .................................................................................................... 8
6. PHOTOGRAPHS OF THE TEST SET-UP ....................................................................... 9
7. LIST OF TABLES .................................................................................................... 13
8. LIST OF PHOTOGRAPHS ......................................................................................... 13
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 4 von 13 Page 4 of 13
1. General Remarks
1.1 Complementary Materials
No attachments along with this test report.
2. Test Sites
2.1 Test Facilities
1. TV Rheinland (India) Pvt. Ltd. Plot No. 108, West Wing, Electronics City Phase 1, Bangalore 560 100 Website: www.ind.tuv.com
This test site is in accordance with CISPR 16 for measurement of radio interference. The used test equipment is in accordance with CISPR 16 for measurement of radio interference. The tests have been conducted by a TV Rheinland testing engineer.
2.2 List of Test and Measurement Instruments
Table 1: List of Test and Measurement Equipment
Kind of equipment Manufacturer Model S/N Calibrated
until
Lab: TUV Rheinland (India) Pvt, Ltd
For Electro Static Discharge (ESD)
ESD Simulator Noiseken ESS 2002 EX ESS0999547 26-Jul-2014
For Radiated Susceptibility (RS)
Signal Generator Agilent E8257D-ATO-1895 MY51110514 04-Feb-2015
RF Power Amplifier MILMEGA 80RF1000-500 1045085 NA
RF Power Amplifier MILMEGA AS0102-200 1045089 NA
RF Power Amplifier MILMEGA AS1860-100 1045088 NA
Stacked Double Logged Periodic Antenna
Schwarz beck STLP9128D 9128D037 01-Nov-2014
Horn Antenna Schwarz beck BBHA9120E BBHA9120E496 01-Nov-2014
Power Meter Agilent N1914A MY50001234 11-Feb-2015
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 5 von 13 Page 5 of 13
3. General Product Information
3.1 Product Function and Intended Use
The EUT is a Smart HOT Watch that works with iPhone, Android and Windows Phones. EUT connects to phones via Blue tooth and enables the user to dial and answer calls directly from the watch. EUT will have a touch screen with a user-friendly interface. The EUT can handle other tasks of phone apart from making and receiving calls. EUT also has gesture support for accepting or rejecting a call.
3.2 Ratings and System Details
Supply Voltage: 5VDC (from USB) Supply Current: 67mA Battery Voltage: 4.2V 3.4V Battery Current: 0.3mA 20mA Protection Class: III
3.3 Independent Operation Modes
The basic operation modes are: A. EUT Paired with phone for voice communication. B. EUT Paired with phone for playing music.
3.4 Noise Generating and Noise Suppressing Parts
Noise Generating and suppressing parts are all parts of design.
3.5 Submitted Documents
None
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 6 von 13 Page 6 of 13
4. Test Set-up and Operation Modes
4.1 Principle of Configuration Selection
Immunity: The equipment under test (EUT) was configured to have its highest possible susceptibility against the tested phenomena. The test modes were adapted accordingly in reference to the instructions for use.
4.2 Physical Configuration for Testing
Refer setup photograph for more details.
4.3 Test Operation and Test Software
During testing EUT was configured in the modes referred in clause 3.3 of this test report. During which Bluetooth communication was monitored continuously.
4.4 Special Accessories and Auxiliary Equipment
Kind of equipment Manufacturer Model
Mobile phone Samsung S3
4.5 Countermeasures to achieve EMC Compliance
No additional measures were employed to achieve compliance.
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 7 von 13 Page 7 of 13
5 . Test Results I M M U N I T Y
5.1 Continuous Disturbances
5.1.1 Radiated Radio-frequency Electromagnetic Fields (RS)
RESULT: PASS
Date of testing: 09-Apr-2014
Ambient temperature: 22.0C Relative humidity: 51% Atmospheric pressure: 91kPa Reference standard: EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012 Test procedure: EN 61000-4-3:2006+A2:2010 Frequency range: (80 - 1000)MHz Test level: 2 (3V/m) (unmodulated, rms.) Frequency range: (1.4 - 2.7)GHz Test level: 2 (3V/m) (unmodulated, rms.)
Modulation: 80% AM, 1kHz Sweep rate: 1%, 2.85s dwell time Test Mode: B Supply voltage During Test: Battery Mode Performance criterion: As per Clause 6 of EN 301489-1
Table 2: Immunity against Radiated Radio-frequency Electromagnetic Fields (RS)
Field Polarization Frequency Range Result Remark
Horizontal 80 1000MHz 1.4 2.7 GHz
Pass Communication was maintained throughout the testing.
Vertical 80 1000MHz 1.4 2.7 GHz
Pass Communication was maintained throughout the testing.
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 8 von 13 Page 8 of 13
5.1.2 Electrostatic Discharges (ESD)
RESULT: PASS
Date of testing: 09-Apr-2014
Ambient temperature: 21.0C Relative humidity: 52% Atmospheric pressure: 91kPa Reference standard: EN 301 489-1 V1.9.2:2011 EN 301 489-17 V2.2.1:2012 Test procedure: EN 61000-4-2:2009 Severity level: 2 (4kV) (contact discharge) 3 (8kV) (air discharge) Number of discharges: >10 Test Mode: A Supply voltage During Test: Battery Mode Performance criterion: As per Clause 6 of EN 301489-1
Table 3: Electrostatic Discharges (ESD), both Polarities
Discharge Points Type of Discharge Result Remark
Top Enclosure:
Contact Pass Communication was maintained throughout the testing. Air Pass
Left Enclosure:
VCP & HCP Pass Communication was maintained throughout the testing.
Right Enclosure:
VCP & HCP Pass Communication was maintained throughout the testing.
Rear Enclosure:
AIR Pass Communication was maintained throughout the testing.
Display:
AIR Pass Communication was maintained throughout the testing.
VCP = Vertical Coupling Plane HCP = Horizontal Coupling Plane
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 9 von 13 Page 9 of 13
6. Photographs of the Test Set-Up
Photograph 1: Set-up for Radiated Susceptibility (RS), Vertical Antenna Orientation
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 10 von 13 Page 10 of 13
Photograph 2: Set-up for Radiated Susceptibility (RS), Horizontal Antenna Orientation
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 11 von 13 Page 11 of 13
Photograph 3: Set-up for Electrostatic Discharges (ESD), VCP & HCP
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 12 von 13 Page 12 of 13
Photograph 4: Set-up for Electrostatic Discharges, Contact
Photograph 5: Set-up for Electrostatic Discharges, Air
-
Produkte Products
Prfbericht - Nr.: Test Report No.:
Draft Report
Seite 13 von 13 Page 13 of 13
7. List of Tables
Table 1: List of Test and Measurement Equipment ...................................................................................... 4 Table 2: Immunity against Radiated Radio-frequency Electromagnetic Fields (RS) .................................... 7 Table 3: Electrostatic Discharges (ESD), both Polarities .............................................................................. 8
8. List of Photographs
Photograph 1: Set-up for Radiated Susceptibility (RS), Vertical Antenna Orientation .................................. 9 Photograph 2: Set-up for Radiated Susceptibility (RS), Horizontal Antenna Orientation ........................... 10 Photograph 3: Set-up for Electrostatic Discharges (ESD), VCP & HCP ..................................................... 11 Photograph 4: Set-up for Electrostatic Discharges, Contact ....................................................................... 12 Photograph 5: Set-up for Electrostatic Discharges, Air ............................................................................... 12