EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

13
EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

description

EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX). Outline. 1. Introduction 2. G rounding strategy 2.1 . Implementations aspects 3. Noise emission issues Test plans 4. Noise immunity issues Test plans 5. Cabling 6.Conclusions. 1. Introduction. - PowerPoint PPT Presentation

Transcript of EMC review for Belle II (Grounding & shielding plans) Sub-systems ( XXXXX)

Page 1: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

EMC review for Belle II (Grounding & shielding plans)

Sub-systems ( XXXXX)

Page 2: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

Outline• 1. Introduction • 2. Grounding strategy

–2.1. Implementations aspects• 3. Noise emission issues

–Test plans• 4. Noise immunity issues

–Test plans• 5. Cabling• 6.Conclusions

Page 3: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

1. Introduction • Short description and schematic of each

subdetector.

Page 4: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

2. Grounding strategy• Outline of the grounding strategy

– Information about current or previous grounding topology.• Single point, multipoint or other

– Describe the actual or proposed grounding topology • Place a conceptual schematic.

– Implementation • Electro-mechanical schematic• Type of grounding connection Bonding or straps?• Capacitors connections ?• …….

• Nest slides shows as an example some of this schematics for PXD system

Page 5: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

2. Grounding strategy - Topology

Single-point

Only for low level and low frequency circuits (below 1 MHz)

Multi-pointFor high level frequency circuits (above 1 MHz)

It prevents excessive radiated emissions and maintains low impedanceBetter filter performance

PXD is very small but the FE Amplifier bandwidth is around100 MHz

Hybrid ground topology is the preferred option as FE amplifier bandwidth is very high – 100 MHz

HybridEquivalent to

Multi-point

Page 6: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

2. Grounding strategy - Topology

PXD Detector

Page 7: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

• PXD connected to the cooling blocks via capacitors – High Frequency Ground Connection

• Cooling blocks connected to Beam pipe ? through direct bonding.

• Beam pipe connected to reference ground system.

7 de 18

2.1 Grounding strategy - Implementation

Detector (FEE)

Cooling block

Beam pipe ?

Reference ground

Cooling pipe

Page 8: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

3. Noise emission issues• Emission issues.

– Analysis of the main noise sources• Identification

– Power supplies, slow control system or any other ???• Test plans

• Remark or comment the main noise sources for the subsystem– Type of noise

• Conducted or radiated ?– Frequency – Possible coupling path

• Test plans .– Noise emissions test plans ?– Show test results in case they have been already

performed.

Page 9: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

4. Noise immunity issues• Analysis of the main noise victims

– Identification • Describe the signal detection circuit (Detector – FEE )

• Schematic• Frequency range where detector circuit expect to be

sensitive.• Possible coupling path

• Describe any other sensitive circuit you expect noise problems

• Test plans .– Noise immunity test plans ?

• Show test results in case they have been already performed.

• Sensitive• Nest slides shows as an example some schematics

of detection circuit for PXD system

Page 10: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

Vsource

Vamplow

S

DG

CG

Clear

Pixel

DCD

Zin (Z??)

Signal

Signal Return

4. Noise immunity issues – Signal circuit

Page 11: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

),( sdsource LCfZ iIs

),( sdamplow LCfZ

iAmplowI

sourceV

AmplowV

cableZ

logAnaGND

.: AmpSoGndZ

),,( fBAfV loopinduced 4. Noise immunity issues – Signal circuit

Signal circuit: PXD

Page 12: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

5. Cabling• Cabling and Shielding aspects

– Type of cables ?– cabling layout ?– Cable connections ?– Grounding of cooling pipes ?– Any other relevant information

Page 13: EMC review for Belle II  (Grounding & shielding  plans) Sub-systems ( XXXXX)

6. Conclusions