4
ASC Anti-Surge Control Systems www.hauckburner.com Automatic vane operation Maintains constant blower discharge pressure Energy savings Eliminates surge pulsations Vane re-swirl reduces blower HP at partial load ASC-1 Edition 07-08 Compatible with all Hauck blowers www.morterahauck.com [email protected]

Transcript of Elster ASC:Elster Triox. · PDF fileFor possible application of a Hauck Anti-Surge Control...

Page 1: Elster ASC:Elster Triox. · PDF fileFor possible application of a Hauck Anti-Surge Control Unit on other than Hauck blowers, consult factory. TBA-1100-45 1212 2212

ASCAnti-Surge Control Systems

www.hauckburner.com

Automatic vane operation•

Maintains constant blower discharge pressure•

Energy savings•

Eliminates surge pulsations•

Vane re-swirl reduces blower HP at partial load•

ASC-1Edition 07-08

Compatible with all Hauck blowers•

www.morterahauck.com [email protected]

Page 2: Elster ASC:Elster Triox. · PDF fileFor possible application of a Hauck Anti-Surge Control Unit on other than Hauck blowers, consult factory. TBA-1100-45 1212 2212

2 • ASC-1 • Edition 07-08

Hauck’s Anti-Surge Control Systems(ASC) are designed to reduce surging pulsations that may disturba combustion process at reducedair flows. These pulsations aremost likely to occur in applicationswhere it is necessary to keep theblower operating during periods ofvery small demand - periods thatmay call for as little as 10 to 20% ofrated volume output of the blower.

The system is comprised of a variable damper which is attachedto the turbo blower inlet flange.Vane position is automaticallydetermined by the systemdemand. Blower surge for a givenblower is a function of the locationof the main air control valve down-stream of the blower dischargeand the system operationalrequirements. Blower surge is automatically controlled by modulating the pressure dropacross the inlet damper vanes,maintaining a constant dischargepressure. The operating point oneach blower curve is kept to theright of the flow rate that wouldallow surging.

Energy savings are an additionalbenefit when using an ASC system.Vane re-swirl reduces blowerhorsepower at partial load andgenerates a different performancecurve at each damper position.Energy costs are lowered byreduced motor amperage draw.With this in mind, the ASC can alsofunction as a system flow regulatorby connecting the control motordirectly to the system demandprocess variable.

For possible application of a HauckAnti-Surge control unit on otherthan Hauck blowers, consult factory.

For additional information on thisproduct, visit our website at:

www.hauckburner.com

Hauck Manufacturing CompanyPOB 90Lebanon, PA 17042

T +1 717-272-3051F +1 [email protected]

Copyright © 2008 Elster Group

The control sequence is illustratedin the figure above. If the demandon the blower is decreased in volume from a normal operatingpoint F, to another normal operatingpoint G, the vanes close to a newposition providing the new flowand maintaining the pressureequal to that at point F.

If the demand is further decreasedin volume from point G to a minimalturndown point, I, the vanes closecompletely and the pressure is stillmaintained at a constant value.

Further volumetric flow decreasesfrom point I cause the pressure torise accordingly towards point J.Note that the blower operatingpoint remains to the right of themaximum pressure point through-out the turndown sequence, reducingthe possibility of surge. Reversingthe demand on the blower causesthe sequence to reverse. Theoperating point on each blowercurve is kept to the right of the flowrate that would allow surging.

www.morterahauck.com [email protected]

Page 3: Elster ASC:Elster Triox. · PDF fileFor possible application of a Hauck Anti-Surge Control Unit on other than Hauck blowers, consult factory. TBA-1100-45 1212 2212

ANTI-SURGE CONTROL SYSTEMS ASC-1000 AND ASC-2000 SERIES

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice. HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051

Fax: 717-273-9882

DIMENSIONS

2/91

GY3

302

ASC-3 www.morterahauck.com [email protected]

Page 4: Elster ASC:Elster Triox. · PDF fileFor possible application of a Hauck Anti-Surge Control Unit on other than Hauck blowers, consult factory. TBA-1100-45 1212 2212

ANTI-SURGE CONTROL SYSTEMS ASC-1000 AND ASC-2000 SERIES

RECOMMENDED ANTI-SURGE CONTROL SYSTEM

In accordance with Hauck’s commitment to Total Quality Improvement, Hauck reserves the right to change the specifications of products without prior notice.

SUPPLEMENTAL DATA

2/91

HAUCK MANUFACTURING CO., P.O. Box 90 Lebanon, PA 17042-0090 717-272-3051 Fax: 717-273-9882 ASC-4

BLOWER MODEL

ASC MODEL

BLOWER MODEL

ASC MODEL

CW CCW CW CCW TBA-12-5 1110 2110

TBA-12-7½ 1112 2112 TBAB-030-040-A 1110 2110 TBA-12-10 1112 2112 TBAB-030-110-B 1110 2110 TBA-12-15 1114 2114 TBAB-040-060-A 1112 2112 TBA-12-20 1114 2114 TBAB-040-060-B 1112 2112 TBA-12-25 1114 2114 TBAB-040-130-C 1112 2112 TBA-12-30 1114 2114 TBAB-040-130-E 1112 2112 TBA-16-7½ 1110 2110 TBAB-050-070-B 1112 2112 TBA-16-10 1110 2110 TBAB-050-070-C 1114 2114 TBA-16-15 1112 2112 TBAB-050-150-E 1114 2114 TBA-16-20 1112 2112 TBAB-060-250-A 1114 2114 TBA-16-25 1114 2114 TBAB-060-250-B 1110 2110 TBA-16-30 1114 2114 TBAB-070-270-B 1110 2110 TBA-16-40 1114 2114 TBAB-070-270-C 1112 2112 TBA-20-5 1110 2110 TBAB-071-271-E 1112 2112 TBA-20-7½ 1112 2112 TBAB-080-290-C 1112 2112 TBA-20-10 1112 2112 TBAB-080-290-E 1112 2112 TBA-20-15 1112 2112 TBAB-081-281-E 1112 2112 TBA-20-20 1112 2112 TBAB-081-291-E 1112 2112 TBA-20-25 1112 2112 TBAB-081-291-F 1112 2112 TBA-20-30 1114 2114 TBAB-090-310-E 1112 2112 TBA-20-40 1114 2114 TBAB-090-310-F 1112 2112 TBA-20-50 1114 2114 TBAB-091-311-G 1112 2112 TBA-20-60 1114 2114 TBAB-091-311-J 1112 2112 TBA-24-5 1110 2110 TBAB-091-341-J 1112 2112 TBA-24-7½ 1110 2110 TBAB-100-330-G 1114 2114 TBA-24-10 1112 2112 TBAB-100-330-H 1114 2114 TBA-24-15 1112 2112 TBAB-100-330-J 1114 2114 TBA-24-20 1112 2112 TBAB-101-321-J 1114 2114 TBA-24-25 1112 2112 TBAB-101-331-J 1114 2114 TBA-24-30 1112 2112 TBAB-101-351-J 1114 2114 TBA-24-40 1112 2112 TBA-24-50 1114 2114 TBA-24-60 1114 2114 TBA-32-40 1210 2210 TBA 50 HERTZ TBA-32-50 1210 2210 TBA-500-3 1110 2110 TBA-32-60 1210 2210 TBA-500-4 1110 2110 TBA-32-75 1212 2212 TBA-500-5.5 1112 2112 TBA-32-100 1218 2218 TBA-500-7.5 1112 2112 TBA-32-125 1218 2218 TBA-500-11 1112 2112 TBA-32-150 1218 2218 TBA-700-3 1110 2110 TBA-36-40 1210 2210 TBA-700-4 1110 2110 TBA-36-50 1210 2210 TBA-700-5.5 1112 2112 TBA-36-60 1210 2210 TBA-700-7.5 1112 2112 TBA-36-75 1212 2212 TBA-700-11 1112 2112 TBA-36-100 1212 2212 TBA-700-15 1112 2112 TBA-36-150 1218 2218 TBA-700-18 1112 2112 TBA-111-361 1218 2218 TBA-900-15 1210 2210 TBA-111-381 1218 2218 TBA-900-18.5 1210 2210

TBA-900-22 1212 2212 TBA-900-30 1212 2212 TBA-1100-18.5 1210 2210 TBA-1100-22 1210 2210 TBA-1100-30 1212 2212 TBA-1100-37 1212 2212

ASC Series & Model Identification: 1100 Series-CW Rotation, Blower Discharge Position 1-7; Short LegJ

1 1200 Series-CW Rotation, Blower Discharge Position 1-7; Long LegJ

2 2100 Series-CCW Rotation, Blower Discharge Position 11-17; Short LegJ

1 2200 Series-CCW Rotation, Blower Discharge Position 11-17; Long LegJ

2 For possible application of a Hauck Anti-Surge Control Unit on other than Hauck blowers, consult factory.

TBA-1100-45 1212 2212