Elevations

1
SOUTH ELEVATION WEST ELEVATION T/ PARAPET EL. 113'- 5"± MAIN LEVEL EL. 100'- 0" EXISTING EAVE EL. 113'- 4"± EXISTING MAIN LEVEL F.F. EL. 100'- 0" NORTH ELEVATION LOWER LEVEL EL. 89'-6" T/O PARAPET EL. 113'- 5"± MAIN LEVEL LOWER LEVEL EL. 89'-6" ALTERNATE #1 EXISTING BASE BID EXISTING EL. 105'- 6" V.I.F. MATCH EXISTING EL. 100'- 0" EAST ELEVATION ALTERNATE #1 EXISTING SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" SCALE: 1/8"=1'-0" T/ PARAPET EL. 113'- 6"± MAIN LEVEL EL. 100'- 0" LOWER LEVEL EL. 89'-6" ALTERNATE #1 (BEYOND) EXISTING (BEYOND) BASE BID (BEYOND) EXISTING 7'-6" 2'-10" KEY PLAN NOT TO SCALE NORTH V.I.F. MATCH EXISTING V.I.F. MATCH EXISTING T/ PARAPET EL. 114'- 0"± T/O ELEVATOR EL. 114'-0" NORTH ELEVATION EAST ELEVATION WEST ELEVATION SOUTH ELEVATION 2 ELEVATIONS AND WALL SECTION A201 EXISTING BUILDING BASE ALT. W1 W1 W1 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 W2 W3 A. CONTRACTOR TO VERIFY EXTERIOR BRICK AND INTERIOR CMU GROUT LINES AND MATCH ALL EXISTING ADJACENT COURSING AND PATTERN (EXCEPT GLAZED TILE). CUT TO FIT STARTER BLOCK IF NECESSARY. B. SEE TYPICAL WALL SECTION #2 ON SHEET 521 FOR DETAILS OF WALL CONSTRUCTION. C. SEE SHEET A002 FOR TYPICAL WINDOW AND EXTERIOR LOUVER DETAILS. D. NOT ALL MECHANICAL EQUIPMENT, DUCTWORK, AND EXTERIOR LOUVERS ARE SHOWN. SEE MECHANICAL DRAWINGS FOR ALL LOCATIONS OF SUCH ITEMS. T/O LOWER PARAPET 1. EXISTING MASONRY VENEER TO REMAIN - VERIFY EXISTING CONDITIONS IN FIELD. 2. PROVIDE MASONRY VENEER TO MATCH EXISTING ADJACENT - SEE SPECS. 3. REMOVE EXISTING LOUVER AND INFILL OPENING WITH MASONRY VENEER TO MATCH EXISTING ADJACENT - SEE WALL SECTION #1 ON SHEET A521 AND COORDINATE BRICK TYPE WITH SPECS (TYP. @ ALL INTERIOR UNIT VENTILATOR LOCATIONS). 4. FINISH GRADE (OR PAVING) - SEE CIVIL DRAWINGS. 5. FOUNDATION WALL - SEE STRUCTURAL DRAWINGS FOR REINFORCING. 6. EXTERIOR DOOR - SEE FLOOR PLANS AND COORDINATE WITH OPENING SCHEDULE. 7. PROVIDE WINDOW TO MATCH EXISTING ADJACENT - SEE SHEET A002 FOR WINDOW TYPES AND DETAILS. 8. CAST STONE SILL - MATCH EXISTING. 9. PROVIDE EXTERIOR LOUVER - SEE HVAC DRAWINGS. 10. PREFINISHED METAL COPING TO MATCH EXISTING ADJACENT. 11. EXISTING COPING TO REMAIN. 12. PREFINISHED METAL RAKE/TRIM - COLOR TO MATCH COPING. 13. PREFINISHED METAL GUTTER - MATCH EXISTING. 14. PREFINISHED METAL DOWNSPOUT WITH CAST IRON BOOT. 15. SCUPPER - SEE ROOF PLAN AND DETAILS ON SHEET A103. 16. PROVIDE PIPE RAILING TO MATCH EXISTING ADJACENT. 17. EXISTING PIPE RAILING - PAINT TO MATCH EXISTING COPING WITH SPECIAL COATING. 18. EXISTING FOUNDATION WALL. 19. EXISTING SHINGLE ROOF TO REMAIN. 20. CONCRETE LIGHT WELL - SEE STRUCTURAL DRAWINGS. 21. REPLACE SASH AND PROVIDE MATERIALS TO PATCH, REPAIR, AND INFILL EXISTING WINDOW SYSTEM TO ORIGINAL FORM, DIMENSION, AND SHAPE. NOT ALL INSTANCES OF A/C UNITS ARE SHOWN - CONTRACTOR TO VERIFY ACTUAL LOCATIONS IN FIELD. DIAMOND NOTES FOR THIS SHEET ONLY: GENERAL NOTES: 4 2 6 5 5 6 9 1 6 3 6 7 8 9 3 10 2 12 11 1 11 4 13 14 10 1 BEYOND 19 BEYOND BEYOND 1 BEYOND 1 3 TYP. 3 TYP. 6 2 20 7 10 11 3 TYP. 17 16 1 9 3 TYP. 8 3 TYP. 11 19 1 1 1 3 4 17 11 19 19 BEYOND 18 18 4 4 19 19 19 19 1 1 4 4 TYP. 2 10 11 BEYOND 1 BEYOND 1 BEYOND 11 BEYOND 2 5 8 3 TYP. 7 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP. 21 TYP. 3 TYP. 21 TYP. 20 16 BEYOND 10 11 TYPE "A" TYPE "A" EXISTING GRADE OMITTED FOR GRAPHIC PURPOSES - CONTRACTOR TO VERIFY ACTUAL GRADES IN FIELD AND COORDINATE WITH CIVIL DRAWINGS 5 4 4 4 21 TYP. 21 TYP. 21 TYP. 14 13 5 4 BRICK TYPE "A" BRICK TYPE "A" BRICK TYPE "B" BRICK TYPE "B" BRICK TYPE "B" BRICK TYPE "A" BRICK TYPE "A" BRICK TYPE "A" BRICK TYPE "A" BRICK TYPE "B" SEE SHEET A501 FOR ELEVATION THIS AREA BEHIND PARAPET BRICK TYPE "B" 9

Transcript of Elevations

Page 1: Elevations

SOUTH ELEVATION

WEST ELEVATION

T/ PARAPET

EL. 113'- 5"±

MAIN LEVEL

EL. 100'- 0"

EXISTING EAVEEL. 113'- 4"±

EXISTING MAIN LEVEL F.F.EL. 100'- 0"

NORTH ELEVATION

LOWER LEVEL

EL. 89'-6"

T/O PARAPET

EL. 113'- 5"±

MAIN LEVEL

LOWER LEVEL

EL. 89'-6"

ALTERNATE #1EXISTINGBASE BIDEXISTING

EL. 105'- 6" V.I.F. MATCH EXISTING

EL. 100'- 0"

EAST ELEVATION

ALTERNATE #1 EXISTING SCALE: 1/8"=1'-0"

SCALE: 1/8"=1'-0"

SCALE: 1/8"=1'-0"

SCALE: 1/8"=1'-0"

T/ PARAPETEL. 113'- 6"±

MAIN LEVELEL. 100'- 0"

LOWER LEVELEL. 89'-6"

ALTERNATE #1

(BEYOND)

EXISTING

(BEYOND)

BASE BID

(BEYOND)EXISTING

7'-6"

2'-10"

KEY PLANNOT TO SCALE

NORTH

V.I.F. MATCH EXISTING

V.I.F. MATCH EXISTING

T/ PARAPETEL. 114'- 0"±

T/O ELEVATOR

EL. 114'-0"

NORT

H EL

EVAT

ION

EAST ELEVATION

WEST ELEVATION

SOUT

H EL

EVAT

ION

2

ELEVATIONS AND

WALL SECTION

A201

EXISTING BUILDING

BASE

ALT.

W1W1W1

W2

W3

W2

W3

W2

W3

W2

W3

W2

W3

W2

W3

W2

W3

W2

W3

A. CONTRACTOR TO VERIFY EXTERIOR BRICK AND INTERIOR CMU GROUT LINES AND MATCH ALL EXISTING ADJACENT COURSING AND PATTERN (EXCEPT GLAZED TILE). CUT TO FIT STARTER BLOCK IF NECESSARY.

B. SEE TYPICAL WALL SECTION #2 ON SHEET 521 FOR DETAILS OF WALL CONSTRUCTION. C. SEE SHEET A002 FOR TYPICAL WINDOW AND EXTERIOR LOUVER DETAILS. D. NOT ALL MECHANICAL EQUIPMENT, DUCTWORK, AND EXTERIOR LOUVERS ARE SHOWN.

SEE MECHANICAL DRAWINGS FOR ALL LOCATIONS OF SUCH ITEMS.

T/O LOWER PARAPET

1. EXISTING MASONRY VENEER TO REMAIN - VERIFY EXISTING CONDITIONS IN FIELD. 2. PROVIDE MASONRY VENEER TO MATCH EXISTING ADJACENT - SEE SPECS. 3. REMOVE EXISTING LOUVER AND INFILL OPENING WITH MASONRY VENEER TO MATCH

EXISTING ADJACENT - SEE WALL SECTION #1 ON SHEET A521 AND COORDINATE BRICK TYPE WITH SPECS (TYP. @ ALL INTERIOR UNIT VENTILATOR LOCATIONS).

4. FINISH GRADE (OR PAVING) - SEE CIVIL DRAWINGS. 5. FOUNDATION WALL - SEE STRUCTURAL DRAWINGS FOR REINFORCING. 6. EXTERIOR DOOR - SEE FLOOR PLANS AND COORDINATE WITH OPENING SCHEDULE. 7. PROVIDE WINDOW TO MATCH EXISTING ADJACENT - SEE SHEET A002 FOR WINDOW

TYPES AND DETAILS. 8. CAST STONE SILL - MATCH EXISTING. 9. PROVIDE EXTERIOR LOUVER - SEE HVAC DRAWINGS. 10. PREFINISHED METAL COPING TO MATCH EXISTING ADJACENT. 11. EXISTING COPING TO REMAIN. 12. PREFINISHED METAL RAKE/TRIM - COLOR TO MATCH COPING. 13. PREFINISHED METAL GUTTER - MATCH EXISTING. 14. PREFINISHED METAL DOWNSPOUT WITH CAST IRON BOOT. 15. SCUPPER - SEE ROOF PLAN AND DETAILS ON SHEET A103. 16. PROVIDE PIPE RAILING TO MATCH EXISTING ADJACENT. 17. EXISTING PIPE RAILING - PAINT TO MATCH EXISTING COPING WITH SPECIAL COATING. 18. EXISTING FOUNDATION WALL. 19. EXISTING SHINGLE ROOF TO REMAIN. 20. CONCRETE LIGHT WELL - SEE STRUCTURAL DRAWINGS. 21. REPLACE SASH AND PROVIDE MATERIALS TO PATCH, REPAIR, AND INFILL EXISTING

WINDOW SYSTEM TO ORIGINAL FORM, DIMENSION, AND SHAPE. NOT ALL INSTANCES OF A/C UNITS ARE SHOWN - CONTRACTOR TO VERIFY ACTUAL LOCATIONS IN FIELD.

DIAMOND NOTES FOR THIS SHEET ONLY:

GENERAL NOTES:

4

2

6

5

5

6

9

1

6

3

67 8

9

310

2

12

11

1

114

13

14

10

1BEYOND

19BEYOND

BEYOND1

BEYOND1

3TYP.

3TYP.

6

2

20

7

10 11

3TYP.

1716 1 9

3TYP.

8

3TYP.

11

19

1

1 13

4

17

11

19

19BEYOND

18

18

44

19 19 1919

1 1

44

TYP. 2

10 11BEYOND

1BEYOND

1BEYOND

11BEYOND

2

58

3TYP.

7

21TYP.

21TYP.

21TYP.

21TYP.

21TYP.

21TYP.

21TYP.

21TYP.

3TYP.

21TYP.

2016 BEYOND

1011

TYPE "A"

TYPE "A"

EXISTING GRADE OMITTED FOR GRAPHIC PURPOSES - CONTRACTOR TO VERIFY ACTUAL GRADES IN FIELD AND COORDINATE WITH CIVIL DRAWINGS

5

4

4

4

21TYP.

21TYP.

21TYP.

14

13

5

4

BRICK TYPE "A"

BRICK TYPE "A"

BRICK TYPE "B" BRICK TYPE "B"

BRICK TYPE "B"

BRICK TYPE "A"

BRICK TYPE "A" BRICK TYPE "A"

BRICK TYPE "A" BRICK TYPE "B"

SEE SHEET A501 FOR ELEVATION THIS AREA

BEHIND PARAPET

BRICK TYPE "B"

9