SOUTH ELEVATION
WEST ELEVATION
T/ PARAPET
EL. 113'- 5"±
MAIN LEVEL
EL. 100'- 0"
EXISTING EAVEEL. 113'- 4"±
EXISTING MAIN LEVEL F.F.EL. 100'- 0"
NORTH ELEVATION
LOWER LEVEL
EL. 89'-6"
T/O PARAPET
EL. 113'- 5"±
MAIN LEVEL
LOWER LEVEL
EL. 89'-6"
ALTERNATE #1EXISTINGBASE BIDEXISTING
EL. 105'- 6" V.I.F. MATCH EXISTING
EL. 100'- 0"
EAST ELEVATION
ALTERNATE #1 EXISTING SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0"
SCALE: 1/8"=1'-0"
T/ PARAPETEL. 113'- 6"±
MAIN LEVELEL. 100'- 0"
LOWER LEVELEL. 89'-6"
ALTERNATE #1
(BEYOND)
EXISTING
(BEYOND)
BASE BID
(BEYOND)EXISTING
7'-6"
2'-10"
KEY PLANNOT TO SCALE
NORTH
V.I.F. MATCH EXISTING
V.I.F. MATCH EXISTING
T/ PARAPETEL. 114'- 0"±
T/O ELEVATOR
EL. 114'-0"
NORT
H EL
EVAT
ION
EAST ELEVATION
WEST ELEVATION
SOUT
H EL
EVAT
ION
2
ELEVATIONS AND
WALL SECTION
A201
EXISTING BUILDING
BASE
ALT.
W1W1W1
W2
W3
W2
W3
W2
W3
W2
W3
W2
W3
W2
W3
W2
W3
W2
W3
A. CONTRACTOR TO VERIFY EXTERIOR BRICK AND INTERIOR CMU GROUT LINES AND MATCH ALL EXISTING ADJACENT COURSING AND PATTERN (EXCEPT GLAZED TILE). CUT TO FIT STARTER BLOCK IF NECESSARY.
B. SEE TYPICAL WALL SECTION #2 ON SHEET 521 FOR DETAILS OF WALL CONSTRUCTION. C. SEE SHEET A002 FOR TYPICAL WINDOW AND EXTERIOR LOUVER DETAILS. D. NOT ALL MECHANICAL EQUIPMENT, DUCTWORK, AND EXTERIOR LOUVERS ARE SHOWN.
SEE MECHANICAL DRAWINGS FOR ALL LOCATIONS OF SUCH ITEMS.
T/O LOWER PARAPET
1. EXISTING MASONRY VENEER TO REMAIN - VERIFY EXISTING CONDITIONS IN FIELD. 2. PROVIDE MASONRY VENEER TO MATCH EXISTING ADJACENT - SEE SPECS. 3. REMOVE EXISTING LOUVER AND INFILL OPENING WITH MASONRY VENEER TO MATCH
EXISTING ADJACENT - SEE WALL SECTION #1 ON SHEET A521 AND COORDINATE BRICK TYPE WITH SPECS (TYP. @ ALL INTERIOR UNIT VENTILATOR LOCATIONS).
4. FINISH GRADE (OR PAVING) - SEE CIVIL DRAWINGS. 5. FOUNDATION WALL - SEE STRUCTURAL DRAWINGS FOR REINFORCING. 6. EXTERIOR DOOR - SEE FLOOR PLANS AND COORDINATE WITH OPENING SCHEDULE. 7. PROVIDE WINDOW TO MATCH EXISTING ADJACENT - SEE SHEET A002 FOR WINDOW
TYPES AND DETAILS. 8. CAST STONE SILL - MATCH EXISTING. 9. PROVIDE EXTERIOR LOUVER - SEE HVAC DRAWINGS. 10. PREFINISHED METAL COPING TO MATCH EXISTING ADJACENT. 11. EXISTING COPING TO REMAIN. 12. PREFINISHED METAL RAKE/TRIM - COLOR TO MATCH COPING. 13. PREFINISHED METAL GUTTER - MATCH EXISTING. 14. PREFINISHED METAL DOWNSPOUT WITH CAST IRON BOOT. 15. SCUPPER - SEE ROOF PLAN AND DETAILS ON SHEET A103. 16. PROVIDE PIPE RAILING TO MATCH EXISTING ADJACENT. 17. EXISTING PIPE RAILING - PAINT TO MATCH EXISTING COPING WITH SPECIAL COATING. 18. EXISTING FOUNDATION WALL. 19. EXISTING SHINGLE ROOF TO REMAIN. 20. CONCRETE LIGHT WELL - SEE STRUCTURAL DRAWINGS. 21. REPLACE SASH AND PROVIDE MATERIALS TO PATCH, REPAIR, AND INFILL EXISTING
WINDOW SYSTEM TO ORIGINAL FORM, DIMENSION, AND SHAPE. NOT ALL INSTANCES OF A/C UNITS ARE SHOWN - CONTRACTOR TO VERIFY ACTUAL LOCATIONS IN FIELD.
DIAMOND NOTES FOR THIS SHEET ONLY:
GENERAL NOTES:
4
2
6
5
5
6
9
1
6
3
67 8
9
310
2
12
11
1
114
13
14
10
1BEYOND
19BEYOND
BEYOND1
BEYOND1
3TYP.
3TYP.
6
2
20
7
10 11
3TYP.
1716 1 9
3TYP.
8
3TYP.
11
19
1
1 13
4
17
11
19
19BEYOND
18
18
44
19 19 1919
1 1
44
TYP. 2
10 11BEYOND
1BEYOND
1BEYOND
11BEYOND
2
58
3TYP.
7
21TYP.
21TYP.
21TYP.
21TYP.
21TYP.
21TYP.
21TYP.
21TYP.
3TYP.
21TYP.
2016 BEYOND
1011
TYPE "A"
TYPE "A"
EXISTING GRADE OMITTED FOR GRAPHIC PURPOSES - CONTRACTOR TO VERIFY ACTUAL GRADES IN FIELD AND COORDINATE WITH CIVIL DRAWINGS
5
4
4
4
21TYP.
21TYP.
21TYP.
14
13
5
4
BRICK TYPE "A"
BRICK TYPE "A"
BRICK TYPE "B" BRICK TYPE "B"
BRICK TYPE "B"
BRICK TYPE "A"
BRICK TYPE "A" BRICK TYPE "A"
BRICK TYPE "A" BRICK TYPE "B"
SEE SHEET A501 FOR ELEVATION THIS AREA
BEHIND PARAPET
BRICK TYPE "B"
9