Page 1: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Dap-06Kp Alarm Keypad

Dap-06 Alarm Panel

Ha-08 Home Automation System

6 ZONE ALARM PANELUSER GUIDE

DAP-06

electrosecR

Dap-06R Card Reader

Rc-06Remote

Access

2008-1 electrosec

Dap-06Kpl-Dap-06kplr Alarm Keypad

Page 2: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

DAP-06 6 ZONE ALARM PANEL

DAP-06 ALARM SYSTEM FEATURES

Programmable 6 Zones

Zone Partition

6 Sec. Long 8 Digital Voice Messege Record

Set / Disable Alarm via landline (Opt.)

Alarm Module with 8 tel. numbers

8 Channel Home Automation System (Opt.)

Keypad with leds and LCD Screen

Keypad connection with 9 addresses

Alarm Monitoring Station Connection

Ademco Contact ID Protocol

Battery Installation and dial tone test

Reminder, Set /Disable Alarm,Battery,

Network Status , Voice Messege sending

Listen Alarm zone sounds (opt.)

Proximity Card Reader connection (opt.)

Set/disable Alarm with card (opt.)

Standard Optional

16-24 Vac. 40 W.

Glass Type (5 Amper)

Micro Processor Controlled Simple Switcher Step Down

12Vdc. 3 amper (Total)

11,8-12,5 dc 1,5 amper (main output)

11,8-12,5 dc 0.5 amper (+ and -alarm outputs )

52 Khz.

Electronic Voltage Shut down (5 sec.)

Total 2.5A and above (Elektronic Voltage Shut down 10 sec.)

+ 125 C

0V 2 ma. Max.

12 Vdc. 7 ampere/hour Ni.cd.

Stand alone Step Down

Glass Type (5 Amper)

8 Channel Adj input micro processor

Programmable 6 zones Analog line

9 Adressable Keypad

Unlimited

250 events per date; set/ disable Alarm, battery

ISDN/PSTN/ADSL 20-52 Vdc.

Ademco Contact ID

-10 /+ 60 C

240 mm. X 255 mm.X 85 mm/ 2000 Gr.

Input Voltage :

Fuse Protection :

Regulator Type :

Output Voltage :

Output Voltage :

Output Voltage :

Switching Frequency :

Short Circuit Protection :

Overcurrent Protection :

Thermal Protection :

Output leakege current :

Battery Voltage :

Battery Charge Circuit :

Battery Protection Fuse :

Control :

Zone :

Keypad Capacity :

Reader Capacity :

Event Capacity :

Communication Line :

Communication Protocol :

Operating Temperature :

Dimensions & Weight :

DAP-06 ALARM PANEL TECHNICAL SPECIFICATIONS

2008-1 electrosec Page 1/19

Page 3: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

DAP-06 6 ZONE ALARM PANEL

DAP-06Kp ALARM KEYPAD TECHNICAL SPECIFICATIONS

10-15 Vdc. Stand by 50 ma. Active100 ma.

Alarm Cable LIY(St) CY 6x0.22mm. / 150 mt.

200 Br. Pull Up Open Collector, single cable communication

4x4 Matrix rubber keypad

2 Line 16 Character Back Light LCD

12 mm. Piezo Buzzer

Electret Microphone

1 /+ 60 C

102 mm. X 142 mm. X 23 mm/ 160 Gr.

4 Pin Socket (+12Vdc, Gnd, Data, Voice)

Input Voltage :

Cable Type and Length :

Panel Communication :

Keypad :

Screen Type :

Audio Warning :

Microphone Type :

Operating Temperature :

Dimensions and Weight :

Link Connector :

DAP-06R CARD READER TECHNICAL SPECIFICATIONS

10-15 Vdc. Stand By 40 ma. Active 60 ma.

Alarm Cable LIY(St) CY 6x0.22mm. / 150 mt.

1200 Br. Pull Up Open Collector, Single Cable Connection

20 Cards

125 Khz. 128 bit Proximity Manchester Data Format

10-15 Cm.

0.1 Sec.

12 mm. Piezo Buzzer

1 /+ 60 C

55 mm.X 11mm. X 26mm/ 86 Gr

3 Pin Socket (+12Vdc, Gnd, Data)

Input Voltage :

Cable Type and Length :

Panel Communication :

Card Capacity :

Card Type :

Card Reading Distance :

Card Reading Speed :

Audio Warning :

Operating Temperature :

Dimensions and Weight :

Link Connector :

HA-08 HOME AUTOMATION SYSTEM TECHNICAL SPEC.

10-15 Vdc. Stand By 1 ma. Active 150 ma.

Alarm Cable LIY(St) CY 6x0.22mm. / 150 mt.

8 Programmable Channels

8 NC, NO ve COMMON Relay Outputs

10 Amper/250 Vac-Vdc.

-10 /+ 60 C

240 mm.X 125 mm. X 50 mm/ 1030 Gr.

5 Pin Screw Type (+12 Vdc. Gnd, R, D, S)

Input Voltage :

Cable Type and Length :

Channel Capacity :

Output Type :

Output Current :

Operating Temperature :

Dimensions & Weight :

Link Connector :

Page 2/19

2008-1 electrosec

Page 4: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 3/19

DAP-06 ALARM PANEL CONNECTION DIAGRAM

16Vac. Input

+ -

12V. 7Ah. Battery

Rc-06Remote Connection

Card

+12Vdc.-Gnd.DataVoice

Ha-08 Home Automation Card

Landline Input

Zon

e 1Z

one 2

Zon

e 3Z

one 4

Zon

e 5Z

one 6

Alarm

+A

larm -

1K Resistance

TamperTamper

- Gnd.+ 12Vdc

KontakKontak

+ 12Vdc- Gnd.

Tamper

Tamper

Trigger

1K Resistance

1 Zone tampered 1 Pır connection

Tamper

Tamper- Gnd.

+ 12Vdc

ContactContact

+ 12Vdc

- Gnd.

TamperTamperContactContact

1K Resistance

1 Zone tampered 2 Pır connection

Common N.O. N.C.

1K Resistance

1K Resistance

Tampered External

Siren Connection

Internal Siren

Dap-06Kp-kpl-kplr Alarm Keypad

Dap-06R Card Reader

Dap-06 Alarm Panel Card

In case of losing admin and technical passwords; short circuit ( Data ) and (B-) ends, turn sytem power offand reconnect after 5 sec.Passwords will go back tofactory settings.

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 5: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 4/19

First connect the 16Vac. transformer, and then 12Vdc. 7Ah. Battery of the panel. Red light will start flashing on the panel. Press Alarm keypad “#” and AUTHORISED MENU will appear on screen. Enter Factory settings password 1-2-3-4-5-6 and wait for a long beep signal for approval to enter the program menu.

This password will reset the alarm. On line 21 on AHM, press “A”key followed by “B” key to enter the previous menu or directly enter the menu number. Press “C”key to enter the menu and press “C” key again to save the changes. Press “D”key to exit the menu without saving, press “D”key again to exit the main menu.

Below are the details of the programming menus.

INSTALLATION and PROGRAMMING

With this menu you can add new user passwords or change the existing passwords. Press ''A''to choose the password you want to change and enter the new password using the keypad. Press ''C'' to save changes. If the password already exits in the system, you will hear short beep signals for error.

MASTER PROGRAM01 CHANGE USER

01 CHANGE USER

****** 111111 01 New Password Old Password No.

With this menu you can delete alarm user passwords. Select the password line no and press “A” delete with “ ” . *

MASTER PROGRAM02 ERASE USER

02 ERASE USER NO 01. 111111Password No.

This menu should be used when the system is connected to Alarm Center. When this passwordis used the system will connect to the Alarm Center and report emergency. Line No 20 should be informed to the Alarm Center.If the password already exits in the system, you will hear short beep signals for error.

03 PANIC CODE

02 ERASE USER

01 CHANGE USER

MASTER PROGRAM03 PANIC CODE

03 PANIC CODE

****** ******

New Password Old Password

04 CHANGE MASTER

With this menu you can change the administrator password.

MASTER PROGRAM04 CHANGE MASTER

04 CHANGE MASTER

****** 123456

MENU 5 and the rest of the menus can be used only with Technical Password. If you want to use these menus with Master Password , go to Menu 43 to change the authorisation of the alarm user.This is a solution to avoid the alarm user to use the technical menus by mistake. Press “#” on alarm keypad for 2 seconds and TECHNICAL will appear on screen. Enter Factory settings password 4-5-6-7-8-9 and wait for a long beep sound for confirmation.

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 6: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 5/19

05 - CHANGE TECH.

With this menu you can change the technical password.

MASTER PROGRAM05 CHANGE TECH.

05 CHANGE TECH.

****** 456789

New Password Old Password

06 - CHANGE TIME

With this menu you can change the date and time of the system

MASTER PROGRAM06 CHANGE TIME

06 CHANGE TIME

Day Month Year Hour Minute

00 / 00 / 2000 00 : 00

07 - CODE DIGIT

With this menu you can change the lenght of the system password - except the tehcnical password.It can be 3,4,5 or 6 digits long. The main point here is that all passwords except the technical password will be deleted and Admin Password will be *123 for 3 digits, *1234 for 4 digits, *12345 for 5 digits and *123456 for 6 digits. Technical password will stay the same. After completing this operation, go to Menu 1 to set the passwords.

MASTER PROGRAM07 CODE DIGIT

07 CODE DIGIT6 DIGITS

08 - ZONE TYPE

With this menu you set the alarm zone in 3 different types;1-NORMAL: Alarm detectors work without a sabotage protection. The alarm will not notice case of intervention on the detection cables and detectors. This option is not recommended ( Factory settings)2-RESISTANCE : Alarm detectors work only when the alarm is set.3-TAMPER :Alarm detectors work in full sabotage protection mode. In case of any intervention, whether the alarm is set or not, the alarm will notice. This option should be used where high protection is necessary.In all options the alarm will notice the intervention of the power cables.

MASTER PROGRAM08 ZONE TYPE

1. NORMAL08 ZONE TYPE

09 - ZONE SETTINGS

With this menu you can set the detector types and the operating options for each zone.

MASTER PROGRAM09 ZONE SETTINGS 1.SET ZONE

09 ZONE SETTINGS

1-DETECTOR: This option is used if you will connect sensors like PIR or Magnetic Contacts to the selected zone .( Factory Settings Default) If you press 'C' on this menu 2 different options will appear.

ZONE 1 DETECTOR

1-NORMAL

ZONE 1 DETECTOR

2-CLEVER

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 7: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 6/19

1-NORMAL:

2-CLEVER:

This option will set the alarm when detectors sense.This is a recommended factory settings default option.

This option will set the alarm on a certain time – to be set in menu 15 – after the detectors sense.If the detectors senses the second time , the alarm will be set.This option should be used where detectors may sense incorrectly because of insects, unstable heat and light. This option is not recommended for normal cases. Select this option and press 'C' and 3 different opitons will appear.

ZONE 1. DETECTOR CLEVER 1-DELAY

ZONE 1. DETECTOR CLEVER 2-INSTANT

ZONE 1. DETECTOR AKILLI 3-FOLLOW

1-DELAY:

2-INSTANT:

3-FOLLOW:

This option should be used if some time is needed during the enterance and exit of the alarm user. The time can be set from Menu 13 and 14. This option is recommended if detectors are connected to door enterences. ( Factory settings) This option should be used if the alarm user does not need time before enterance or exit . Recommended for places like window and balcony, where delay is not needed.

This option should be used when alarm user will first use the Delay Zone and then the Instant Zone. The only difference is that this option will work when the delay zoneis on.Otherwise FOLLOW option will be on.

This option should be used when a panic button is connected to the system. When pressing the button, the system will send a signal to the Alarm Contact Center without any visual or audio message. This option makes it possible for the Banks or Jewelery stores to send a signal without any panic.

2-

3-SILENT 24 HOURS:

4-SABOTAGE 24 HOURS:

FIRE 24 HOURS: This option should be used when there are smoke and heat detectors.If this option is selected ALARM (-) port will be active and only fire detectors will be on power.In case of fire, press 'C' to stop the power of the detectors for a time, specified in Menu 16. This and the other options after this one, the zone will be on whether the alarm is set or not.

This option should be used if there is an external siren connectionto the system.Tamper connections are entered to the zone to avoid sabotage.

10 ZONE PARTITION

The authorisation for setting a zone of passwords and cards can be set with this menu.You can make partitions in your system by giving every password and card, a different authorisation for setting up zones.

MASTER PROGRAM10 ZONE PARTITION 123456 B 01.LINE

10 ZONE PARTITION

On the left corner you will see numbers 123456 and on the right corner are the passwords and cards starting from 01. LINE. Factory settings come with authorisation for all passwords and cards to set zone. With numbers 1-6, you can add/remove autorisation of the zones.The zone without authorisation is shown with X. Press A and the line number to select the other passwords and cards authorisation.

With this menu you can select the alarm of each zone with siren or silent. Silent zones willnot alert with siren but will connect to Alarm Monitoring Station. With numbers 1-6 activate/

11 - ZONE SIREN

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 8: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 7/19

deactivate the siren. The silent zone is shown with X, and zone number for others.

MASTER PROGRAM

11 ZONE SIREN 123456 SELECT11 ZONE SIREN

With this menu you can set the Enterance time of the alarm user. Using the keypad you canset a time between 001- 255 seconds. When alarm is set you can see this time as countdownon the screen. If there is not a DELAY status set, the time must be entered 001.

12 - ENTRY TIME

MASTER PROGRAM12 ENTRY TIME 010 Sec.

12 ENTRY TIME

With this menu you can set the Exit time of the alarm user. Using the keypad you can set a timebetween 001- 255 seconds. When alarm is set you can see this time as countdown on the screen.If there is not a DELAY status set, the time must be entered 001.

13 - EXIT TIME

MASTER PROGRAM13 EXIT TIME 010 Sec.

13 EXIT TIME

With this menu you can set the time if there is a smart detector. You can enter time between 20-225 seconds. As mentioned above in Menu 10 on the second sense of the detector will alert. After this time is finished the detector will ignore.

14 - CLEVER TIME

MASTER PROGRAM14 CLEVER TIME 020 Sec.

14 CLEVER TIME

This menu is for hearing the sound of alarm set up and cancel from the siren. Factory settingsdefault is OFF. Press 1 to turn it ON, 2 for OFF. When alarm is ON once for 0,5 seconds, and 3 times for 0,3 seconds when alarm is OFF only alarm input (+) will be active. So that you will beable to hear when it is ON / OFF.

15 - WARNING SIREN

MASTER PROGRAM15 WARNING SIREN 1-OFF

15 WARNING SIREN

With this menu you can program the (+) and (-) time for the alarm. The system has two differentalarm inputs. This menu defines how long these inputs will be active.If one of the zones in the system are on FIRE 24 HOURS status , ALARM (-) input will be the power for the detector. If one of the fire zones alert, press 'C' to reset, if not the system will reset automatically in 15 minutes.

16 - ALARM TIME

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 9: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 8/19

MASTER PROGRAM16 ALARM TIME 1- + ALARM TIME

16 ALARM TIME + ALARM TIME003 Min.

MASTER PROGRAM16 ALARM TIME 2- - ALARM TIME

16 ALARM TIME - ALARM TIME010 Sec.

INPUT (+) can be programmed between 001-225 minutes. This input is usually used to switch on the external siren

INPUT (-) can be programmed between 001-225 minutes.This input is usually used to switch on the internal siren. If one of the zones in the system are on FIRE 24 HOURS status , ALARM (-) input will be the (-) GND power for the detector. The detectors will be reset after the time set in the fire alarm.

To set the alarm without a password, press '0' for 2 seconds. It is number 22 on Alarm Monitoring Station.

17 ONE KEY ARM

2 - OFF17 ONE KEY ARM

1 - ON17 ONE KEY ARM

This menu should be used if the system is connected to the Alarm Monitoring Station.On the Alarm Keypad, Keys 1-3 for POLICE, 4-6 for AMBULANCE , 7-9 for FIRE STATION , sends the Emergency alerts to the Alarm Monitoring Station. Press these keys for 2 seconds, the information will be shown on the screen.

18 EMERGENCY KEYS

MASTER PROGRAM18 EMERGENCY 1 - ON

18 EMERGENCY

This menu should be used for connection to the Alarm Monitoring Station.1-Enter the 4 digit Account Number received form the Alarm Monitoring Station in the ACCOUNT Menu.2-Enter the settings for the reports to be sent to the Alarm Monitoring Station in the SET UP Menu.

19 - M.S. SETTINGS

19 M.S. SETTINGS 1-ACCOUNT19 M.S. SETTINGS

This menu should be used if the system is connected to the Alarm Monitoring Station. Up to 14 digits can be entered as the telephone number of the AMS.(A and B) keys for more numbers.

20 - AHMP PHONE

20 M.S.PHONE

20 M.S. PHONE

1**************

21 - INT. PHONE

This menu should be used if the system is connected to an internal number. Press the number which is used to reach an external number and save with 'C'. Maximum 4 digits can be entered.

MASTER PROGRAM

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

MASTER PROGRAM

****

19 M.S. SETTINGSACCOUNT

cc

19 M.S.SETTINGS

cc

cc 19 M.S.SETTINGS

cc2-SET UP

19 M.S. SETTINGS

** : **hour minute

17:00+4th HOUR

hour minute + repeat time

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 10: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 9/19

MASTER PROGRAM21 INT. PHONE ****

21 INT.PHONE

Enter the internal phone number

MASTER PROGRAM22 EXT. PHONE **************

22 EXT.PHONE1

Enter the external phone number Line no

22 - EXT. PHONE

There is a telephone dialer in the system which gives voice messages and sounds to 8 differentnumbers. Select this menu and enter maximum 14 digit numbers. Press 'C' to save.Dialing starts from No 1. Use 'A' to enter the other numbers.

With this menu you can set the dialer of the system to be ON ( ENABLE) or OFF (DISABLE) during alarm time.If it is OFF the telephone will not make a call, if ON ; use 1-4 to set up.

23 - ALARM DIALER

23 ALARM DIALER2- DISABLE23 ALARM DIALER

1- ENABLE

23 ALARM DIALER1.TUR

The system makes calls in two different types. DTMF type may not work in old type landlines.Factory settings default is DTMF ENABLED. If the system can not make DTMF calls, to turn it off, select 1-DISABLE.

24 DTMF CALL2- DISABLE24 DTMF CALL

1- ENABLE

24 - DTMF CALL

25 LINE ALARM 25 LINE ALARM2- DISABLE

This menu is to check the dialtone of the landline the system is connected to. You will see 'LINE TEST ' on the screen, after entering all the passwords to set up the system.The system isready after receiving the dial tone. If the system does not receive a dial tone in 15 seconds youwill see ' NO LINE' on screen an hear an error message and the system is set up without thedialing module after 3 seconds. If the system receives a dial tone after the set up, it will automatically switch on the dialing module. If the landline connection is lost after set up, there will be an alarm for once. Before switching on this option, you must go to Menu 35 to test the landline and make sure there is a dial tone.

Use this menu if you want the alarm to work realtime. Use the keypad to enter the time according to 24 hours and save with 'C'. The alarm will be on either the zones are on or off.AMS number 23.

1- ENABLE

25 - LINE ALARM

26 - AUTO ARM

MASTER PROGRAM26 AUTO ARM

26 AUTO ARM

** **:Hour : Minute

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 11: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 10/19

Use this menu if you want the cancel the alarm to work realtime. Use the keypad to enter the timeaccording to 24 hours and save with 'C'. The alarm will be on either the zones are on or off. AMS number 23.

27 AUTO DISARM

MASTER PROGRAM26 AUTO DISARM

26 AUTO DISARM

** **:Hour : Minute

There are 8 voice messages in the system. You can record voice messages 6 seconds long anduse these messages in the system as you desire. Recommeded option is to use these messagesfor the names of the different zones. Because during an alarm the system will dial the saved numbers and these messages will be listened. Select 1-8 REC. MESSAGE and press 'C'. When you see ' SPEAK' on the screen , approach 30cm. to the microphone on the right hand side of the keypad and start speaking with a normal voice. The message will be automatically over after 6 seconds.If your message is shorter, press 'C' to save.

28 REC.MESSAGE

MASTER PROGRAM28 REC.MESSAGE

28 REC.MESSAGE1. REC.MESSAGE SPEAK 6Sec.

28 REC.MESSAGE

With this menu you can assign the voice messages recorded in Menu 28, to diffrent zones.Factory settings are MESSAGE 01.for ZONE 1 , MESSAGE 02 for ZONE 2, MESSAGE 03 for ZONE 3, MESSAGE 04 for ZONE 4, MESSAGE 05 for ZONE 05, MESSAGE 06 for ZONE 6.

29 ZONE MESSAGE

MASTER PROGRAM29 ZONE MESSAGE

29 ZONE MESSAGE1.ZONE 1. ZONE 1.MESSAGE

29 ZONE MESSAGE

First choose the zone, and press 'C' to check the assinged message.

You can use the messages created in MENU 28 for different purposes. Recommended usage is to select the messages other than zone messages. Factory settings default is DISABLED.Press the following; 1- TIME to enter day/month/year and hour/minute for future reminders2- BAT. (BATTERY) for system power off.3- ELEC.(ELECTRICITY) for system power on4- ARM for when alarm system is armed5- DARM (DISARM) for when alarm system is disarmed6- ACC.(ACCESS) if the system has remote access module 7- LBAT.(LOW BATTERY) for when system battery is lowFor all options , first select the appropriate message number, then press 'C' to confirm. You can choose the telephone number for the messages from the following menu.

30 SPECI.MESSAGE

MASTER PROGRAM30 SPECI.MESSAGE

30 SPECI.MESSAGE

1-TIME

1- TIME DISABLE30 SPECI.MESSAGE

1- TIME 7-MESSAGE30 SPECI.MESSAGE

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 12: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 11/19

This is the menu to set the telephone number for the special messages created in Menu 29.Select the telephone numbers entered in menu 22 as external numbers. Factory system default has no numbers.Press between 1-8 to select.

MASTER PROGRAM31 SPECI.PHONE

31 SPECI.PHONESELECT ********

31 - SPECI.PHONE

Use this menu if you have HA-08 HOME AUTOMATION SYSTEM. Home automation systemhas 8 channels, each can be programmed seperately. Factory settings default come with BUTTON option ready. Select the port to program and save with 'C'.Below are the details for these options;

tatus changes each time you press the key. Active for the first time you press ( a sound for 0,5 seconds is heard for confirmation) andpassive for the second time ( a sound for 0,5 seconds is heard twice). Generally used to control electrical devices like heating systems, garden irrigation or ovens.

1-BUTTON : This option makes the related channel of the Home Automation System,operateas “BUTTON”. The s

32 - AUTOMATION

32 AUTOMATION1. CH.

32 AUTOMATION1. CH. 1-BUTTON

3-ALARM : This option releases the channel from the telephone line and activates duringan alarm. You can turn on the light to be safer during the alarm.

32 AUTOMATION1. CH 2-BUTTON

32 AUTOMATION1. CH.

32 AUTOMATION1. CH. 3-ALARM

4-BATTERY : This option is active when the system power (220v) is working on the batterybecause of an electricity failure. It is automatically turned off when system power is back on.Generally used for generators, ups, exit lights.

32 AUTOMATION1. CH. 4-BAT.

5-WARNING : This option is active when there is an alert coming from a zone, set up in the zone warning option in Menu 40. For example; when there is an alert from Zone 1 you can make the bell connected to Channel 5, ring for 1-255 seconds.

32 AUTOMATION1. CH 5-WARNING

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

2-PUSH BUTTON : This option makes that channel of the Home Automation System operate as switch, when connected to the system via the telephone line. It is active for the time youkeep Pushing the button.Genereally used for garage gates.

Page 13: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

6-ACTIVE : This option is active when the zone defined is ON. For example; when Zone 1 is active you can switch off the electricity, water or gas system of your house.

32 AUTOMATION1. CH. 6-ACTIVE

32 AUTOMATION123456 SELECT

7-TRIGGER : This option triggers the system on a specified time for 1-59 seconds. For example; the ring connected to Channel 1 will ring at 12:00 for 20 seconds.

32 AUTOMATION1. CH. 7-TRIGER

32 AUTOMATION 01 Sec. ** :**

Start Hour : Time Time Set

8-TIME : This option activates the selected channel on a specified time.Generally used for daily routine things to do. For example; you can set the heating system of your office, to be on, in winter between 08:00 and 17:30 on a daily routine for an economical choice.

32 AUTOMATION1. CH. 8-TIME

32 AUTOMATION

** **:Start Hour : Minute

** **:End Hour : Minute

With this menu you can set the remote connection option to be on, by setting the line for how many times to ring. Factory setting default is 3 Times.

33 AUTO ANSWER

MASTER PROGRAM33 AUTO ANSWER

33 AUTO ANSWER3.RING

The system is avaliable to download information remotely using a computer software. Press'C' to enter the menu and enter the telephone number for the system to connect, and press 'C' again to save. The system will download information for 1 minute from the telephone.During this operation, the keypad will be locked and flashing. Generally technical staff use this option, to download information easily and fast.

34 DOWNLOAD

MASTER PROGRAM34 DOWNLOAD

34 DOWNLOAD

**************

You can define weather the system should wait for a dial tone for making calls. Factory settingsdefault is set as DISABLED. In some cases you might need to set up on the card if the dial tonein different frequencies. 01-ENABLE and 02-DISABLE. Use Key 3 to test the dial tone.

35 DIAL TONE

MASTER PROGRAM35 DIAL TONE

35 DIAL TONE1-DISABLE

36 CARD RECORD

The system operates safer using DAP-06R proximity card reader , instead of using passwords.

Page 12/19

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 14: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

Page 13/19

Connect DAP-06R proximity card reader to the system using the diagram on page 4 and press'C'. The sign 'ACTIVE' will flash on the card reader, start reading the cards to be used in the system.After each card you will see the line number for the card.If the system will be connectedto an Alarm Monitoring Station , the user names of the cards should be informed to the AMS. The system can have maximum 20 cards. The 20th card is in the same status as Emergency Password.When the 20th card is read, Emergency status will be sent.You can set zone authorisation of the cards with the numbers you set in Menu 10.

MASTER PROGRAM36 CARD RECORD

36 CARD RECORDREAD CARD

You can delete the cards from the system by entering the card numbers. Enter the number and press'C' to delete. If the number exits in the system you will see ' VALID' notice on the cardreader and hear a confirmation tone.If not, you will see 'INVALID' notice on the reader and hear short beeps for error.

37 CARD ERASE

MASTER PROGRAM37 CARD ERASE

37 CARD ERASELINE : 01

Use this menu if there are more than one DAP-06Kp Alarm keypads. There can be 1-9 addressedkeypads in the system. The purpose of the addressing is to avoid a mix up between the microphones of the keypads during voice recording and voice listening in an alarm. All keypads are addressed to 1 in factory settings default. If there is no addressing there will be joint keypadaudio. Every keypad used in the system should be addressed seperately between 1-9.

38 KEYPAD ADDRES

MASTER PROGRAM38 KEYPAD ADDRES

38 KEYPAD ADDRESADDRES NO: 2

With this menu you can name the 6 zones in the system according to their region. Factory settings are ZONE-01/06. Follow the instructions on the screen to change the names and PRESS 'C' to save. Use keys A and B to select the zone and keys * and + to move left or right. The titles can be maximum 8 digits.

39 ZONE TITLE

MASTER PROGRAM39 ZONE TITLE

39 ZONE TITLEZONE-01 * #

The warnings from zones can be listened when alarm is NOT ARMED. The warnings can alsoflash if you have HA-08 Home Automation System. With this menu, select the regions and the duration of the flashing between 001-255 seconds.

40 ZONE WARNING

MASTER PROGRAM40 ZONE WARNING

40 ZONE WARNING 1-ENABLE

1 SELECT *****40 ZONE WARNING 40 ZONE WARNING

001 Sec.

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

cc

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 15: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

41 LANGUAGE

Select language TURKISH or ENGLISH with this menu.

MASTER PROGRAM41 LANGUAGE

41 LANGUAGE 1-ENGLISH

You can set the alarm users authorisation for related menus. Give authorisation according to usersdesire. But do not forget that giving authorisation for technical menus may lead to problems and user errors. Menus 01-05 are only for alarm authorised user. Menus 05-43 are only for technical users not avaliable to change. Use keys A and B to select the menu and select 01-ENABLE or 02-DISABLE ,and press 'C' to save. All avaliable menus are 01-ENABLE in factory settings.

43 - AUTHORISE

MASTER PROGRAM43 AUTHORISE

06 AUTHORISE 1-ENABLE

cc

42 EVENT MEMORY

With this menu you can follow up the event logs the system automatically records for Alarm Arm/Disarm, electrical failure / activation and alarm. * key deletes all event logs.

MASTER PROGRAM42 EVENT MEMORY SYSTEM RESET

cc

cc

cc

cc

01 / 01 / 2000 00 : 00 Use keys (A) and (B) to select the next event log.System will start to overwrite starting from first event after 250 logs.

DAP-06 6 ZONE ALARM PANEL

ALARM ARM /DISARMTo use the alarm, there should be at least 1 user password or 1 promixity card card saved in the system and the detectors in the zone should not be detecting in the zone the password or the cardused. If you want to set the alarm during detection press 'C' for 2 seconds. Make sure about this and enter your password or read your card. You will see ' INSTALLING'on the screen and the finishtime descending. In this case, leave the alarm zone. A beep for confirmation will be heard and 'ACTIVE' sign on the screen if all the zones are set, or the information of the zone if partly activated.‘A'for active sign will flash until the alarm is completely finished.

01/01/2007 15:30ACTIVE

01/01/2007 15:3012 ACTIVE****

All zones armed Zone 1.and 2. armed

Systemis usingelectricity

System battery sign, Battery is low if sign is flashing

To disarm the alarm, enter zone with the keypad or card reader, if the detectors detected flashingon the keypad is visible or warning tone is heard also a countdown will appear.You need to enteryour password or read you card before this countdown is over.If the correct password is not entered or correct card is not read, alarm sirens will activate.In this case, the system will send information to the Alarm Monitoring Station, if connected or activate the dialer to send voice messages to the saved telephone number. After sending the voice message there will be beep sound and a pause for 2 seconds, the message will be resent in 45 seconds. During this pause if your system has RC-06 Remote Access card, if you enter the keypad adress (1-9) by using your the keypad of your telephone, siren will be off and the microphone on the keypad is activated and the sounds of the alarm zone will be heard. After deciding on the alarm reason press 0 to reactivate the siren and redial if there are different numbers. Press (*) to cancel other calls and stop the siren and go back to alarm active mode.

ALARM USAGE

Load testing; when Alarm is not armed and there is electricty and batteryconnection, system automatically disconnects electricity and loads full poweron battery for 15 sec. every hour, for battery load testing.If battery is lowa short beep warning is heard 3 times. In this case contact your reseller.

IMPORTANT WARNING ABOUT BATTERY!!!

Page 14/19 2008-1 electrosec

Page 16: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

DAP-06 6 ZONE ALARM PANEL

ARM/DISARM ALARMIf there is a RC-06 Remote Access card in the system , the telephone number stored in the alarmwill be dialed. The telephone will be answered automatically according to the time set up in Menu 33. If you have set a welcome message in Menu 30 it will be heard.When you enter the alarm user password after the message ends, the microphone on the alarm keypad is turned on,to listen to the sounds and the process also to check if there are intruders inside.In this case,if you enter the password wrong 3 times, the system cancels the remote access until the Master Password is entered. * sign flash on the keypad if the remote access is cancelled.

REMOTE ACCESS USAGE

If you have RC-06 Remote Access and HA-08 Home Automation in the system, the telephone number will be dialed and ring as long as programmed in Menu 33. If you have set a welcomemessage in Menu 30 it will be heard. After entering the factory settings default password 1-2-3-4-5-6, wait for the long beep for confirmation and enter the automation system. Use keys 1-8 to proceed in the automation system. There will be no warning for channels with PUSH BUTTON settings. 1 short confirmation beep for BUTTON active when channel is active and 2 short beeps for deactivewill be heard. If you enter the password wrong 3 times, the system is cancels the remote access until the Master Password is entered. * sign flash on the keypad if the remote access is cancelled. Automation channels can not be controlled other than BUTTON or PUSH BUTTON options. For other options go to Menu 32.

TELEPHONE AUTOMATION USAGE

You can turn on/off the keypad tones for confirmation and error. Press 'D' for 2 seconds for this option. After each pressing, you will hear a short beep and the tones will be on/off.

KEYPAD TONES ON / OFF

ALARM MONITORING STATION CODES

S.01-19

S.01-19

S.21

B.1-6

B.1-6

B.1-6

B.1-6

----------

----------

----------

----------

----------

3401

1401

1401

1130

1137

1110

1122

1301

3301

1461

1305

1302

ALARM ARMED

ALARM DISARMED

MASTER PASSWORD CANCELLED

BURGLAR ALARM

SABOTAGE ALARM

FIRE ALARM

SILENT ALARM

POWER OFF

POWER RESTORED

WRONG PASSWORD(ACTIVE)

SYSTEM RESET

BATTERY LOW

LINE ZONE

---------

---------

---------

---------

S.21

S.21

--------

S.20

S.20

S.22

S.23

S.23

1100

1110

1120

1351

1306

1621

1312

3121

1121

3408

3403

1403

EMERGENCY KEY

EMERGENCY KEY FIRE

EMERGENCY KEY PANIC

PHONE LINE DISCONNECTED

PANEL PROGRAM CHANGE

EVENT MEMORY RESET

SYSTEM OVERLOAD

DURESS CODE ALARM

DURESS CODE ALARM CANCEL

ONE KEY ARM

AUTOMATIC ARM

AUTOMATIC DISARM

LINE ZONE

CODE CODE DEFINITIONS CODE CODE DEFINITIONS

Page 15/19

2008-1 electrosec

Page 17: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

DAP-06 6 ZONE ALARM PANEL

BY-PASS SETTING

6 zones can be individually disable, B press the button for it,appear on the screen BY-PASS after enter the master code thenappear on the screen zone status, what zone this key. (Toggle type) It appear for revoked zonal Please confirm key. Revoked zonal light will be flashed

If you want to cancel it is pressed

BY-PASS:

cB

ZONE : 1 2 3 4 5 6 CANCEL : *

cc

Go to Menu 09-Zone Settingsand select Zone 6 Sabotage 24H.In this case Alarm will alert whensiren lid is opened or cables are cut.

IMPORTANT NOTICE :This connection type is the safest recommended typeof connection.Select TAMPER mode from Menu 8ZONE SETTINGS. These settings will be applied to allzones.Zones without detectors must be connected toCOM inputs with 1K Resistance. Otherwise they will beon SABOTAGE alarm mode.

CONNECTION TO ZONE 6 WITH 1K RESISTANCE (+)TRIGGER

In this connectionall switches must be down.

1K resistancemust be

in the siren

TAMPER CONNECTION

EXTERNAL SIREN CONNECTION

Page 16/19 2008-1 electrosec

Page 18: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

PIR DETECTOR CONNECTION

Page 17/19

Select 01.ZONE DETECTORMODE in MENU 09-ZONE SETTINGS.In this casedetectors will alert whenlid is opened or cables are cut.

ZONE 1 connection with 1K+1K Resistance

TAMPER CONNECTION

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

IMPORTANT NOTICE 1 : Do not makeserial connection for more than 4 PIR detectors for 1 zone in TAMPER connection.

1K resistancemust be in the siren

IMPORTANT NOTICE :This connection type is the safest recommended typeof connection.Select TAMPER mode from Menu 8ZONE SETTINGS. These settings will be applied to allzones.Zones without detectors must be connected toCOM inputs with 1K Resistance.

Page 19: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

TROUBLESHOOTING

Page 18/19

Alarm keeps ringing and does not stop even if the password is entered!

System is in TAMPER mode in MENU 08-ZONESETTINGS and zones without detector connectionsare not connected to COM port with 1K resistance.Reconnect resistances and re-enter the password.

Continuous (-) output on (-) output! System is in FIRE 24H mode in MENU 09-ZONE

SETTINGS. In this case ALARM (-) output are usedas (-) output for Fire Detectors.

System can not be armed!

Go to MENU 01- CHANGE USER to set a password and use the new password to ARM/DISARM.The new password must have authorisation to enterat least 1 zone in MENU 10-ZONE SETTINGS.

System has no 12 Vdc. output!

System locks outputs to prevent short circuits and1.5 A overcurrents. Check system output cables andthe total system current. OVERCURRENT notice willappear on KEYPAD on MENU-42 EVENT MEMORY.

Dialer is not activated during Alarm!

Check MENU 22-EXT.PHONE, at least 1 phone number must be entered in the system.MENU 23-ALARM DIALER Menu must be 1-ENABLEand 1-4 TUR must be selected.If other settings are entered in Monitoring StationMenus, this feature does not operate.

Voice messages can not be listenedduring Alarm!

Complete settings in MENU 28-REC. MESSAGE, Select zones in MENU 29-ZONE MESSAGE for thesemessages.If other settings are entered in Monitoring StationMenus, this feature does not operate.

Siren does not operate during Alarm!

Check MENU 11-ZONE SIREN if zones are in Silentmode.

System does not dial Special Messages

Check MENU 22-EXT. PHONE for telephone numbersand selected from MENU 31 SPE. MESSAGES.

System does not dial at all!

Check MENU 35-DIAL TONE if it is 1-ENABLEand the dial tone may be incompatible. Go to03-TEST mode and using the trinpot on card,test until you see “AVALIABLE”on screen.

PROBLEM SOLUTION

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec

Page 20: electrosec R · Kontak Kontak + 12Vdc - Gnd. Tamper Tamper Trigger 1K Resistance 1 Zone tampered 1 Pır connection Tamper Tamper ... With this menu you can add new user passwords

TROUBLESHOOTING

Page 19/19

Some menus can not be entered error sound is heard!

Check MENU 43-AUTHORISE settings for limitations Select 01-ENABLE to enter with Master Password.

System does not record voice messages!

Check the connection on Alarm main board Keypad VIE output.

Keypad lights are on but the deviceis not working!

Check DATA connection on Alarm main board Keypad output.

No warning tone is heard when pressing keys on KEYPAD!

Press and hold KEYPAD “D” key for 2 sec.Tones will be active after a short beep.

Alarm can not be armed during detector is operating!

Press and hold KEYPAD “C”key for 2 sec.Alarm will be armed after a long beep.

MANUFACTURER

ELEKTROSEC Güvenlik Sistemleri

Sanayi ve Ticaret Limited Şirketi

Cemal Sururi Sok. No: 1-2 Mecidiyeköy/İSTANBUL

Tel:+90 2122120310-3474690 Pbx

Fax:+902123474692

Email: [email protected]

Web: www.electrosec.com

PHISICAL LIFE5 years.

MAINTANENCEKeep the device dry, if it gets wet dry immediately, liquids contain harmful ingredients for electronicdevices.Keep in normal temperature, heat changes shortens physical life, deformates plastic parts.

USAGE FAULTSVoltage changes or faulty electiric network, problems caused by usage in different voltages other than mentioned on product label, usage other than mentioned in users manual are out of warranty.

CARRYING INSTRUCTIONSDevice should be fixed on a flat ground, do not keep in humid or wet places

AUTHORISED RESELLER

PROBLEM SOLUTION

DAP-06 6 ZONE ALARM PANEL

2008-1 electrosec