Electronically compensated clip-on CT's up to 100 A · Precautions for use of electronically...
Transcript of Electronically compensated clip-on CT's up to 100 A · Precautions for use of electronically...
Clip-on CT's Electronically compensated clip-on CT's up to 100 A
The electronically compensated clip-on CT's has been designed for the measurements of currents in the range of 10 mA up to 100 A. Their small size makes them particularly handy when working in cramped spaces such as me-ter installations or circuit breaker boards.
Application
The clip-on CT's are suitable for following de-vices:
Portable Reference Standards: PRS 400.3 / CALPORT 300
Portable Working Standards: PWS 3.3 / PWS 2.3 PLUS
Portable Standard Meters: CheckMeter 2.3 / CheckMeter 2.1 / PSM 2.1
Portable Test Systems: PTS 2.1 / PTS 2.3 C / PTS 3.1 / PTS 3.3 C / CheckSystem 2.3 / CheckSystem 2.1
Portable Instrument Transformer Tester: PTT 2.1
Technical data
• Cable length: 2 m
• Weight: approx. 330 g
• Dimensions:
Err
or
co
mp
en
sati
on
an
d a
dap
tati
on
bo
xes
Th
ree p
hase
clip
-on
CT
´s
Co
nn
ecto
r ty
pe
of
ded
icate
dR
ed
el p
lug
s
PRS 400.3
CALPORT 300
PWS 3.3
PWS 2.3 PLUS
CheckMeter 2.3
PTS 3.3 C
PTS 2.3 C
CheckSystem 2.3
Co
mp
on
en
ts o
fth
e c
lip
-on
CT
´s
9 p
ole
s, sin
gle
row
keyin
g s
yste
m
H25
Y30 0
00 8
18 2
01
Fo
r cu
rren
ts u
p t
o 1
0A
UC
T10.3
14 p
ole
s, double
row
keyin
g s
yste
m
H25
Y30 0
00 8
17 1
01
Fo
r cu
rren
ts u
p t
o 1
00
A14 p
ole
s, double
row
keyin
g s
yste
mU
CT
100.3
Hxx x
xx x
xx x
xx x
xx
Fo
r cu
rren
ts u
p t
o 1
00
A
Resis
tance
com
pensate
d
H25
Y30 0
00 0
10 0
03
Fo
r cu
rren
ts u
p t
o 1
00
A14 p
ole
s, sin
gle
row
keyin
g s
yste
m
Ele
ctr
onic
err
or
com
pensation
in the
instr
um
ent
Err
or
co
mp
en
sati
on
an
d a
dap
tati
on
bo
xes
Sin
gle
ph
ase
clip
-on
CT
Co
nn
ecto
r ty
pe
of
ded
icate
dR
ed
el p
lug
s
PRS 400.3
CALPORT 300
PWS 3.3
PWS 2.3 PLUS
CheckMeter 2.1
PSM 2.1
PTS 3.1
CheckSystem 2.1
PTS 2.1
PTT 2.1
Co
mp
on
en
ts o
fth
e c
lip
-on
CT
14 p
ole
s, double
row
keyin
g s
yste
m
The clip-on CT´s can be exchanged independently of the instruments
The clip-on CT´s are adjusted with the instrument and cannot be exchanged
Hxx x
xx x
xx x
xx x
xx
H25
Y30 0
00 8
18 2
01
Fo
r cu
rren
ts u
p t
o 1
00
A
Fo
r cu
rren
ts u
p t
o 1
00
A6 p
ole
s, sin
gle
row
keyin
g s
yste
m
Ele
ctr
onic
err
or
com
pensation
in the
instr
um
ent
UC
T100.1
H25
Y30 0
00 8
17 1
01
Fo
r cu
rren
ts u
p t
o 1
00
A14 p
ole
s, sin
gle
row
keyin
g s
yste
m
Ele
ctr
onic
err
or
com
pensation
in the
instr
um
ent
Hxx x
xx x
xx x
xx x
xx
Fo
r cu
rren
ts u
p t
o 1
00
A9 p
ole
s, sin
gle
row
keyin
g s
yste
m
Resis
tance
com
pensate
d
Precautions for use of electronically compensated clip-on CT's
Install the electronically compensated clip-on CT's to test circuitry
Disconnect the electronically compen-sated clip-on CT's from test circuitry
Step 1
Connect the elec-tronically compen-sated clip-on CT's to the instrument.
Step 1
Disconnect the elec-tronically compen-sated clip-on CT's from the test circuitry.
Step 2
Connect the supply of the instrument with the auxiliary or measuring voltageand start up the in-strument.
Step 2
Switch off the instru-ment and disconnect them from the aux-iliary or measuring voltage.
Step 3
Connect the elec-tronically compen-sated clip-on CT's to the test circuitry.
Step 3
Disconnect the elec-tronically compen-sated clip-on CT's from the instrument.
Never take away the power supply of the instrument or unplug the CT-connector, during the clip-on CT's are
connected to cables with current flowing.
If these precautions are not followed, the instrument can be damaged
www.mteturkey.com
Ostim Mahallesi Alınteri Bulvarı,Gül 86 Yapı Koop.1151 SokakNo:1/86 Ostim/Yenimahalle/ANKARA
+90 (312) 309 20 86
+90 (312) 309 20 86+90 (312) 309 20 87
+90 (312) 309 20 86