Electron Eu Matic A

89
095011 GB Fundamentals of Electropneumatics Collection of Transparencies 2 1 3 3 3 1 1 2 2

description

neumatica

Transcript of Electron Eu Matic A

  • 095011 GB

    Fundamentals of

    Electropneumatics

    Collection of

    Transparencies

    2

    1 3

    33

    11

    22

  • Order No.: 095011

    Description: EL-PN.FOLIEN-GS

    Designation: D:OT-TP201-GB

    Edition: 02/2000

    Author: Frank Ebel

    Graphics: Doris Schwarzenberger

    Layout: 10.05.2000, Beatrice Huber

    Festo Didactic GmbH & Co., D-73770 Denkendorf, 2000

    Internet: www.festo.com/didactic

    e-mail: [email protected]

    The copying, distribution and utilization of this document as well as the

    communication of its contents to others without expressed authorization is

    prohibited. Offenders will be held liable for the payment of damages. All rights

    reserved, in particular the right to carry out patent, utility model or ornamental

    design registration.

  • Foreword

    Festo Didactic GmbH & Co. Electropneumatics

    The Collection of Transparencies is conceived for the basic material of the TP200

    Electropneumatic Technology Package. The transparency collection and technology

    package form part of the The Learning System for Automation from Festo Didactic

    GmbH & Co.

    The transparencies are designed from a didactical and methodological point of view.

    For each transparency, there is a short accompanying text that provides the speaker

    with a quick overview of the contents. More information you will find in the textbook

    Electropneumatics.

    Physical fundamentals of electropneumatics

    Function and application of electropneumatic components

    Designation and drawing of electropneumatic symbols

    Drawing of pneumatic and electrical circuit diagrams in accordance with

    standards

    Presentation of motion sequences and switching conditions

    Direct and indirect manual controls

    Direct and indirect direction-dependent controllers

    Logical AND/OR functions

    Pressure-dependent controls with pressure switches

    Troubleshooting in simple electropneumatic control systems

    The text pages contain a complete picture of the transparency with some additional

    explanations and items which the speaker can mark on the transparency during

    instruction.

    The advantages of this concept are:

    The speaker can add to the transparencies step-by-step during instruction.

    Instruction is livelier.

    The accompanying texts provided reduce preparation time.

    The enclosed CD-ROM contains all the overhead transparencies and accompanying

    text of this edition in an electronically presentable form in the files

    Electropneumatics _ transparencies.pdf and Electropneumatics _text.pdf. In

    addition to the screen presentation, which can be made in any order, the contents

    can be printed out and text and graphics can be used for your own training

    preparations, insofar as the functionality of the required Adobe

    Acrobat

    Reader

    permits this. This freely distributable software is available on the CD-ROM in the

    currently valid English version for Windows 95/98/NT for installation in the directory

    Acrobat_Reader. Please start the file rs405eng.exe and follow the subsequent

    dialogue.

    Syllabus

    New!

    Electronic presentation

  • Contents

    Festo Didactic GmbH & Co. Electropneumatics

    System Elements

    Elements of a Control Chain __________________________________ Transparency 1

    Pneumatic Components

    Single-Acting Cylinder _______________________________________ Transparency 2

    Double-Acting Cylinder ______________________________________ Transparency 3

    Non-return, Flow Control and Pressure Control Valves_____________ Transparency 4

    Pressure Regulating Valve____________________________________ Transparency 5

    One-Way Flow Control Valve __________________________________ Transparency 6

    Quick Exhaust Valve_________________________________________ Transparency 7

    Electropneumatic Components

    Conversion of Electrical Signals into Pneumatic Signals ___________ Transparency 8

    Conversion of Pneumatic Signals into Electrical Signals ___________ Transparency 9

    Switching Symbols for Valves ________________________________ Transparency 10

    Directional Control Valves: Ports and Switching Positions_________ Transparency 11

    Function Principle of a Solenoid Coil __________________________ Transparency 12

    2/2-Way Solenoid Valve without Pilot Control __________________ Transparency 13

    Solenoid Valves with Pilot Control ____________________________ Transparency 14

    3/2-Way Single Solenoid Valve with Pilot Control _______________ Transparency 15

    5/2-Way Single Solenoid Valve with Pilot Control _______________ Transparency 16

    5/2-Way Double Solenoid Valve with Pilot Control_______________ Transparency 17

    5/3-Way Solenoid Valve ____________________________________ Transparency 18

    Electrical Components

    Power Supply Units ________________________________________ Transparency 19

    Switching Contacts and Types of Actuation_____________________ Transparency 20

    Types of Actuation of Switching Elements ______________________ Transparency 21

    Switching Symbols for Solenoid Coils and Relays________________ Transparency 22

    The Relay ________________________________________________ Transparency 23

    Magnetic Proximity Switches (Reed Switches) __________________ Transparency 24

    Electrical Output Devices____________________________________ Transparency 25

    Logic Functions

    The AND Logic Function _____________________________________ Transparency 26

    The OR Logic Function ______________________________________ Transparency 27

  • Contents

    Festo Didactic GmbH & Co. Electropneumatics

    Electropneumatic Controller

    Control Chain _____________________________________________ Transparency 28

    Direct Actuation of a Single-Acting Cylinder ____________________ Transparency 29

    Indirect Actuation of a Double-Acting Cylinder __________________ Transparency 30

    Electrical Memory Circuit Dominant Set ______________________ Transparency 31

    Electrical Memory Circuit Dominant Reset ____________________ Transparency 32

    Electropneumatic Memory Circuit with Double Solenoid Valve _____ Transparency 33

    Stroke-Dependent Control___________________________________ Transparency 34

    Pressure-Dependent Control_________________________________ Transparency 35

    Circuit Diagram Design

    The Electropneumatic Circuit Diagram _________________________ Transparency 36

    Circuit Diagram Structure ___________________________________ Transparency 37

    Displacement-Step Diagram _________________________________ Transparency 38

    Terminal Connection Diagram

    Terminal Connection Diagram ________________________________ Transparency 39

    Checklist for the Terminal Connection Diagram__________________ Transparency 40

    Special Features with the Connection of Solenoid Coils

    Protective Circuits for Inductive Loads _________________________ Transparency 41

    Programmable Logic Controllers

    Alterable Controls__________________________________________ Transparency 42

  • 1 Festo Didactic GmbH & Co. Electropneumatics

    Elements of a Control Chain

    The principle of the control chain is used for the preparation of the circuit diagram.

    Every element of a control chain has a certain task to perform in the processing and

    further transmission of signals.

    This structuring of a system into functional blocks has proven itself in the following

    tasks:

    Arrangement of the elements in the circuit diagram

    Definition of the nominal sizes, nominal current and nominal voltage of

    components

    Set-up and commissioning of the controller

    Identification of the components for maintenance work

    Electric motors

    Solenoids

    Linear motors

    Power contactors

    Power transistors

    Power thyristors

    Switches

    Push button

    actuators

    Limit switches

    Program

    module

    Sensors

    Electrics/ Electronics

    Switches

    Push button actuators

    Limit switches

    Program module

    Sensors

    Indicators/generators

    Contactors

    Relays

    Electronic modules

    Pneumatics/ Hydraulics

    Directional

    control valves

    Directional

    control valves

    Isolating valves

    Pressure valves

    Working elements

    Control elements

    Processingelements

    (Control elements)

    Input elements

    Cylinders

    Motors

    Components

  • Festo Didactic GmbH & Co. TP 201, 01Transparency

    Elements of a Control Chain

    Electrics/Electronics

    Power contactors

    Power transistors

    Power thyristors

    Switches

    Push button actuators

    Limit switches

    Program module

    Sensors

    Indicators/generators

    Contactors

    Relays

    Electronic modules

    Electric motors

    Solenoids

    Linear motors

    Pneumatics/Hydraulics

    Directional

    control valves

    Directional

    control valves

    Isolating valves

    Pressure valves

    Working elements

    Control elements

    Processingelements

    (Control elements)

    Input elements

    Cylinders

    Motors

    Components

    Switches

    Push button

    actuators

    Limit switches

    Program

    module

    Sensors

  • 2 Festo Didactic GmbH & Co. Electropneumatics

    Single-Acting Cylinder

    Compressed air is applied to only one side of the single-acting cylinder.

    The piston rod side of the cylinder is vented to atmosphere.

    Single-acting cylinders can perform work in only in the advance direction of travel.

    The piston rod is driven inwards by the force of a built-in spring or by external forces.

    Piston

    Reset spring

    Piston rod

    Bearing capEnd cap

    Exhaust portSealing ring

    Supply port Cylinder barrel

  • Festo Didactic GmbH & Co. TP 201, Transparency 02

    Single-Acting Cylinder

  • 3 Festo Didactic GmbH & Co. Electropneumatics

    Double-Acting Cylinder

    The double-acting cylinder is actuated in both directions with compressed air.

    It can perform work in both directions of movement.

    The force transmitted to the piston rod is greater during the advance stroke than

    during the return stroke.

    End cap

    Piston Piston rod

    Bearing cap

    Scraper ring

    Cylinder barrel

  • Festo Didactic GmbH & Co. TP 201, Transparency 03

    Double-Acting Cylinder

  • 4 Festo Didactic GmbH & Co. Electropneumatics

    Non-return, Flow Control and Pressure Control Valves

    Non-return valves block the flow in one direction and release it in the opposite

    direction. A distinction is made between:

    Non-return valves

    Shuttle valves (OR)

    Dual pressure valves (AND)

    One-way flow control valves

    Quick exhaust valves

    Pressure control valves influence the pressure or are controlled through the size of

    the pressure. A distinction is made between:

    Pressure regulating valves

    Pressure relief valves

    Pressure sequence valves

    Sloping arrow the valve is adjustable

    Non-return valves

    Flow control valve

    Pressure control

    valve

    Non-return valve (check valve)

    Flow control valve (throttle valve), adjustable

    Non-return valve, spring-loaded

    Shuttle valve (OR function)

    Quick exhaust valve

    One-way flow control valve

    Adjustable pressure regulating valve without relief port

    Adjustable pressure regulating valve with relief port

    Pressure sequence valve with external supply line

    Pressure-relief valve

    Pressure sequence valve-combination

    Dual pressure valve (AND function)

    12

    3

    2

    2

    2

    2

    1

    1

    1

    1

    3

    12

    2

    1

  • Festo Didactic GmbH & Co. TP 201, Transparency 04

    Non-return, Flow Control and Pressure Control Valves

    Non-return valves

    Flow control valve

    Pressure control

    valve

    Non-return valve (check valve)

    Flow control valve (throttle valve),adjustable

    Non-return valve, spring-loaded

    Shuttle valve (OR function)

    Quick exhaust valve

    One-way flow control valve

    12

    3

    Adjustable pressure regulating valvewithout relief port

    Adjustable pressure regulating valvewith relief port

    Pressure sequence valvewith external supply line

    Pressure-relief valve

    2

    2

    2

    2

    1

    1

    1

    1

    Pressure sequencevalve-combination

    3

    12

    2

    1

    Dual pressure valve (AND function)

  • 5 Festo Didactic GmbH & Co. Electropneumatics

    Pressure Regulating Valve

    Pressure regulators have the function of keeping the output pressure mainly

    constant, independent of variations in the input pressure and the air consumption.

    If the pressure rises at the outlet, the diaphragm moves against the spring force and

    the flow cross-section at the valve seat is reduced or closed.

    If the pressure drops at the outlet, the spring presses against the diaphragm and the

    passage cross-section at the valve seat is enlarged or opened.

    The output pressure is adjustable.

    The input pressure must be higher than the output pressure.

    P1 P2 P1 P2

    1

    3

    2

  • P1 P2

    Festo Didactic GmbH & Co. TP 201, Transparency 05

    Pressure Regulating Valve

    1

    3

    2

    P1 P2

  • 6 Festo Didactic GmbH & Co. Electropneumatics

    One-Way Flow Control Valve

    The check element blocks the flow of air in one direction, so that it flows across an

    adjustable throttle in this direction.

    The air flow from the opposite direction lifts the seal of the check element from the

    seat. The compressed air can flow almost unrestricted in this direction.

    The valve should be installed as close as possible to the cylinder.

    4

    5

    2

    1Y1 1Y2

    31

    1A

    1V2 1V3

    1V1

  • Festo Didactic GmbH & Co. TP 201, Transparency 06

    One-Way Flow Control Valve

    4

    5

    2

    1Y1 1Y2

    31

    1A

    1V2 1V3

    1V1

  • 7 Festo Didactic GmbH & Co. Electropneumatics

    Quick Exhaust Valve

    Quick exhaust valves are used to achieve the maximum advance and retract speed

    of pneumatic cylinders.

    To increase the effectiveness of the valve, it should be mounted directly on the

    cylinder or in the immediate vicinity of the supply or exhaust ports of the cylinder.

    2

    3

    2

    1Y1

    1 3

    1A

    1

    1V2

    1V1 1V1

    2

    3

    1Y2

    13

    1A

    1

    1V2

    4

    5

    2

    2

    1

    3

    2

    1

    3

  • Festo Didactic GmbH & Co. TP 201, Transparency 07

    Quick Exhaust Valve

    2

    3

    2

    1Y11 3

    1A

    1

    1V2

    1V1 1V1

    2

    3

    1Y2

    13

    1A

    1

    1V2

    4

    5

    2

    2

    1 3

    2

    1

    3

    2

    1

    3

  • 8 Festo Didactic GmbH & Co. Electropneumatics

    Conversion of Electrical Signals into Pneumatic Signals

    If control systems are using compressed air and electricity as working mediums,

    converter systems must be used.

    Solenoid valves convert electrical signals into pneumatic signals.

    Solenoid valves consist of:

    A pneumatic valve

    A coil which switches the valve

    2

    1 3

    unactuated actuated

    33

    11

    22

  • 21 3

    Festo Didactic GmbH & Co.

    Conversion of Electrical Signals into Pneumatic Signals

    unactuated actuated

    33

    11

    22

    TP 201, Transparency 08

  • 9 Festo Didactic GmbH & Co. Electropneumatics

    Conversion of Pneumatic Signals into Electrical Signals

    The PE converter is actuated with compressed air. When the pressure reaches a

    preset value, an electric signal is generated.

    The pressure of a pneumatic signal works against an adjustable spring.

    If the pressure working against the diaphragm overcomes the spring force, a stem

    actuates an electrical switch contact.

    The electrical switching element can be normally closed, normally open or

    changeover contact.

    14

    1414

    unactuatedactuated

  • Festo Didactic GmbH & Co. TP 201, Transparency 09

    Conversion of Pneumatic Signals into Electrical Signals

    14

    1414

    unactuatedactuated

  • 10

    Festo Didactic GmbH & Co. Electropneumatics

    Switching Symbols for Valves

    Pneumatic components are normally shown in the deenergized condition in circuit

    diagrams.

    Valve switching positions are represented by a square.

    The number of squares corresponds to the number of switching positions.

    Functions and modes of operation are drawn inside the square:

    Lines indicate the flow paths.

    Arrows indicate the flow direction.

    Closed ports are represented by two lines drawn at right angles to one another.

    The connecting lines are drawn outside on the square.

    The valve switching position is shown by a square.

    The number of squares corresponds to the number of switching positions.

    Lines indicate the flow paths, arrows indicate the direction of flow.

    Closed ports are shown by two lines drawn at right angles to one another.

    The connecting lines for supply and exhaust air are drawn outside the square.

  • Festo Didactic GmbH & Co. TP 201, Transparency 10

    Switching Symbols for Valves

    The valve switching position is shown by a square.

    The number of squares corresponds to the number of switching positions.

    Lines indicate the flow paths, arrows indicate the direction of flow.

    Closed ports are shown by two lines drawn at right angles to one another.

    The connecting lines for supply and exhaust air are drawn outside the square.

  • 11

    Festo Didactic GmbH & Co. Electropneumatics

    Directional Control Valves: Ports and Switching Positions

    Information about the type of valve can be established from the following features:

    Number of ports

    Number of switching positions

    Port numbering

    The following applies to the numbering of the ports:

    Air supply port 1

    Exhaust ports 3, 5

    Working or outlet ports 2, 4

    2/2-way valve, normally open position

    4/2-way valve flow from 1 2 and from 4 3

    5/2-way valve flow from 1 2 and from 4 5

    5/3-way valve, mid-position closed

    3/2-way valve, normally closed position

    3/2-way valve, normally open position

    Number of switching positions

    Number of ports

    4

    4

    4

    2

    2

    2

    2

    2

    2

    3

    3

    3

    3

    3

    1

    1

    1

    1

    1

    1

    5

    5

  • Directional Control Valves:Ports and Switching Positions

    2/2-way valve, normally open position

    4/2-way valveflow from 1 2 and from 4 3

    5/2-way valveflow from 1 2 and from 4 5

    5/3-way valve, mid-position closed

    3/2-way valve, normally closed position

    3/2-way valve, normally open position

    Number of switching positions

    Number of ports

    4

    4

    4

    2

    2

    2

    2

    2

    2

    3

    3

    3

    3

    3

    1

    1

    1

    1

    1

    1

    5

    5

    Festo Didactic GmbH & Co. TP 201, Transparency 11

  • 12

    Festo Didactic GmbH & Co. Electropneumatics

    Function Principle of a Solenoid Coil

    When an electric current flows through a coil, a magnetic field is generated.

    The following applies to the strength of the magnetic field:

    Increasing the number of windings increases the field.

    Increasing the strength of the current increases the field.

    Lengthening the coil reduces the field.

    A soft iron core (armature) is drawn into a coil through which a current is flowing.

    Coil winding

    Soft iron core

  • Festo Didactic GmbH & Co. TP 201, Transparency 12

    Function Principle of a Solenoid Coil

    Coil winding

    Soft iron core

  • 13

    Festo Didactic GmbH & Co. Electropneumatics

    2/2-Way Solenoid Valve without Pilot Control

    Normally-closed position, spring return

    Solenoid coil deenergized

    Port 1 is blocked.

    Port 2 is blocked.

    Exhausting is not possible.

    Solenoid coil energized

    The armature is raised.

    Compressed air flows from port 1 to port 2.

    2

    1

    1 12 2

  • Festo Didactic GmbH & Co. TP 201, Transparency 13

    2/2-Way Solenoid Valve without Pilot Control2

    1

    1 12 2

  • 14

    Festo Didactic GmbH & Co. Electropneumatics

    Solenoid Valves with Pilot Control

    Solenoid valves with pilot control consist of:

    An electromagnetically-actuated pilot control valve.

    A pneumatically-actuated main valve.

    In comparison with solenoid valves without a pilot control, solenoid valves with a

    pilot control are distinguished by:

    Lower force required to actuate the armature.

    Smaller dimensions of the coil head.

    Lower power consumption.

    Less heat generated.

    An electrical signal isapplied to the solenoidcoil

    The solenoid coilactuates the pilotcontrol valve

    The pilot controlactuates the valve

  • Festo Didactic GmbH & Co. TP 201, Transparency 14

    Solenoid Valves with Pilot Control

    An electrical signal isapplied to the solenoidcoil

  • 15

    Festo Didactic GmbH & Co. Electropneumatics

    3/2-Way Single Solenoid Valve with Pilot Control

    Normally-closed position, spring return, manual override

    Solenoid coil deenergized

    Port 1 is blocked.

    Port 2 is vented to port 3.

    The pilot control channel is blocked by the armature seal on the valve side.

    The space above the valve piston is vented through the armature guide tube.

    Solenoid coil energized

    The armature is lifted and the armature seal on the coil side blocks the vent hole

    in the armature guide tube, while the armature seal on the valve side opens the

    pilot control channel.

    Compressed air from port 1 flows through the pilot control channel and actuates

    the valve piston.

    Port 3 is blocked.

    Compressed air flows from port 1 to port 2.

    2

    1 3

    33

    11

    22

  • 21 3

    Festo Didactic GmbH & Co.

    3/2-Way Single Solenoid Valve with Pilot Control

    33

    11

    22

    TP 201, Transparency 15

  • 16

    Festo Didactic GmbH & Co. Electropneumatics

    5/2-Way Single Solenoid Valve with Pilot Control

    Spring returned, manual override

    Solenoid coil deenergized

    Compressed air flows from port 1 to 2.

    Port 4 is vented to 5.

    Port 3 is blocked.

    The pilot control channel is blocked.

    The space above the valve piston is vented through the armature guide tube.

    Solenoid coil energized

    The armature is lifted and the armature seal on the coil side blocks the vent in

    the armature guide tube, while the armature seal on the valve side opens the

    pilot control channel.

    Compressed air from port 1 flows through the pilot control channel and actuates

    the valve piston.

    Port 5 is blocked.

    Compressed air flows from port 1 to port 4.

    Port 2 is vented to port 3.

    4

    4

    2

    2

    1

    1

    14

    14

    3

    3

    5

    5

    84

    84

    3

    3

    2

    2

    1

    1

    4

    4

    5

    5

    84

    84

    14

    14

  • Festo Didactic GmbH & Co. TP 201, Transparency 16

    5/2-Way Single Solenoid Valve with Pilot Control

    4

    4

    2

    2

    1

    1

    14

    14

    3

    3

    5

    5

    84

    84

    3

    3

    2

    2

    1

    1

    4

    4

    5

    5

    84

    84

    14

    14

  • 17

    Festo Didactic GmbH & Co. Electropneumatics

    5/2-Way Double Solenoid Valve with Pilot Control

    Manual override

    Solenoid coil Y1 energized, solenoid coil Y2 deenergized

    The valve switches over.

    Port 3 is blocked.

    Compressed air flows from Port 1 to Port 2.

    Port 4 is vented to Port 5.

    Both solenoid coils deenergized

    The valve retains its previous switching position.

    Solenoid coil Y2 energized, solenoid coil Y1 deenergized

    The valve switches over.

    Port 5 is blocked.

    Compressed air flows from port 1 to port 4.

    Port 2 is vented to port 3.

    4

    4

    2

    2

    1

    1

    14

    14

    12

    12

    3

    3

    5

    5

    84

    84

    82

    82

    3214584 82

    14 12

    3214584 82

    14 12

  • Festo Didactic GmbH & Co. TP 201, Transparency 17

    5/2-Way Double Solenoid Valve with Pilot Control

    4

    4

    2

    2

    1

    1

    14

    14

    12

    12

    3

    3

    5

    5

    84

    84

    82

    82

    3214584 82

    14 12

    3214584 82

    14 12

  • 18

    Festo Didactic GmbH & Co. Electropneumatics

    5/3-Way Solenoid Valve

    The three switching positions of an electrically-actuated pilot-controlled

    5/3-way valve:

    1. In the normal position, the solenoid coils are deenergized and the piston is

    centered in its mid-position by the two springs. Ports 2 and 3 as well as 4 and 5

    are connected. Port 1 is blocked.

    2. If current is applied to the lefthand solenoid coil, the piston moves to the right.

    Ports 1 and 4 as well as 2 and 3 are connected with each other.

    3. If current flows through the righthand solenoid coil, the piston moves to the left.

    In this position, Ports 1 and 2 as well as 4 and 5 are connected.

    Each of the two actuated switching positions is held as long as current flows through

    the corresponding solenoid coil. If the flow of current is interrupted, the piston

    switches back to the mid-position.

    4

    4

    2

    2

    5

    5

    3

    3

    1

    1

    12

    12

    14

    14

    84

    84

    82

    82

    4 2

    5 31

    1214

    84 82

    3

    3

    3

    2

    2

    2

    1

    1

    1

    4

    4

    4

    5

    5

    5

    84

    84

    84

    82

    82

    82

    14

    14

    14

    12

    12

    12

  • TP 201, Transparency 18 Festo Didactic GmbH & Co.

    4

    4

    2

    2

    5

    5

    3

    3

    1

    1

    14

    14

    12

    12

    14

    14

    84

    84

    82

    82

    4 2

    5 31

    5/3-Way Solenoid Valve

    14 1214

    84 82

    3

    3

    3

    2

    2

    2

    1

    1

    1

    4

    4

    4

    5

    5

    5

    84

    84

    84

    82

    82

    82

    14

    14

    14

    12

    12

    12

  • 19

    Festo Didactic GmbH & Co. Electropneumatics

    Power Supply Units

    It is necessary to distinguish between an alternating current and a direct current

    power supply.

    Is supplied from the mains

    3-phase or single-phase form

    Sinusoidal-shaped voltage of fixed frequency

    Relatively constant amplitude

    Voltage change through transformers

    Is supplied by power supply devices

    Modules of direct current power supply devices

    Mains transformer

    Rectifier

    Stabilization

    Batteries and rechargeable batteries

    Used for buffering in case of mains failure.

    Used in portable devices.

    +

    Transformer StabilizerRectifier

    Power supply unit

    Alternating current Direct current Battery

    Alternating current

    Direct current

  • Festo Didactic GmbH & Co. TP 201, Transparency 19

    Power Supply Units

    Transformer StabilizerRectifier

    Power supply unit

    Alternating current Direct current Battery

    +-

  • 20

    Festo Didactic GmbH & Co. Electropneumatics

    Switching Contacts and Types of Actuation

    The following switch contact designs are used as input and processing elements:

    Normally-open contact

    Normally-closed contact

    Changeover contact

    Types of actuation for switching elements are:

    Manual

    Mechanical

    Relay

    Magnet field

    Normally-opencontacts

    Changeoverswitch

    Mechanically connectedcontacts

    Rotary switch withnormally open contactsmanually actuatedby turning

    Push-button withnormally open contactsmanually actuatedby pushing

    Limit switch with normally openor normally closed contacts,mechanically actuated

    Normally-closedcontacts

  • Festo Didactic GmbH & Co. TP 201, Transparency 20

    Switching Contacts and Types of Actuation

    Normally-opencontacts

    Changeoverswitch

    Mechanically connectedcontacts

    Rotary switch withnormally open contactsmanually actuatedby turning

    Push-button withnormally open contactsmanually actuatedby pushing

    Limit switch with normally openor normally closed contacts,mechanically actuated

    Normally-closedcontacts

  • 21

    Festo Didactic GmbH & Co. Electropneumatics

    Types of Actuation of Switching Elements

    Frequently used types of actuation are

    Pushbuttons

    Roller levers

    Roller lever with idle return

    Two types of actuation are shown

    Pushbutton, as changeover switch

    Latching rocker switch, as normally-open contact

    Identifying letters in electrical circuit diagrams: S (S1, S2, ...)

    Connection(normally-closed contact)

    Connection(normally-open contact)

    Switching element

    Type of actuation(push-button)

    4

    3

    2

    1

    4

    3

    4 4

    3

  • Festo Didactic GmbH & Co. TP 201, Transparency 21

    Types of Actuation of Switching Elements

    4

    3

    2

    1

    4

    3

    4 4

    3

    Connection(normally-closed contact)

    Connection(normally-open contact)

    Switching element

    Type of actuation(push-button)

  • 22

    Festo Didactic GmbH & Co. Electropneumatics

    Switching Symbols for Solenoid Coils and Relays

    In electropneumatics, the solenoid coil is the element that switches the valves.

    Identifying letters in electrical circuit diagrams: Y (Y1, Y2, ...)

    A relay switches 1, 2 or more contacts. The relay can also be a time or temperature-

    controlled element.

    Identifying letters in electrical circuit diagrams: K (K1, K2, ...)

    Y1

    K1

    Electro-magneticallyactuated on both sides

    Electro-magneticallyactuated,with pilot control

    Contactor or relay with3 normally open contactsand 1 normally closed contact

    Electro-magneticallyactuated on one side,with spring return

    Representation inelectrical circuitdiagrams

  • Festo Didactic GmbH & Co. TP 201, Transparency 22

    Switching Symbols for Solenoid Coils and Relays

    Electro-magneticallyactuated on both sides

    Electro-magneticallyactuated,with pilot control

    Contactor or relay with3 normally open contactsand 1 normally closed contact

    Electro-magneticallyactuated on one side,with spring return

    Representation inelectrical circuitdiagrams

    K1

    Y1

  • 23

    Festo Didactic GmbH & Co. Electropneumatics

    The Relay

    In practice, the construction of a relay can be very different, but the function is

    nevertheless the same in principle:

    When a voltage is applied to the relay coil through contacts A1 and A2, an

    electric current flows through the windings. A magnetic field is built up and pulls

    the armature against the core of the coil.

    Switch contact 1 is connected with switch contact 4.

    After removing the voltage, the armature is brought back into its initial position

    by a spring.

    Switching contact 1 is connected with switching contact 2.

    A relay can have multiple switching contacts which can be actuated simultaneously.

    There are the following types, for example:

    Polarised relay

    Current impulse relay

    Time relay

    Thermal relay

    124A1 A2

    A1

    A2

    221412 24

    11 21

    Coil core

    Insulation

    Contact

    Return spring

    Relay coil

    Armature

  • Festo Didactic GmbH & Co. TP 201, Transparency 23

    The Relay

    Coil core

    Insulation

    Contact

    Return spring

    Relay coil

    Armature

    124A1 A2

    A1

    A2

    221412 24

    11 21

  • 24

    Festo Didactic GmbH & Co. Electropneumatics

    Magnetic Proximity Switches (Reed Switches)

    Reed switches are actuated through a magnetic field. In industrial applications, most

    reed switches are used with LED displays.

    The illustration shows a three-wire reed switch. It has three connections:

    One connection for the positive power supply

    One connection for the negative power supply

    One signal or switch output

    The reed switch is attached directly to the body of a cylinder. It is actuated by a

    magnetic ring on the cylinder piston.

    When the magnetic ring moves past the reed switch, the switching contacts are

    closed as a result of the magnetic field and thus provide an output signal.

    Identifying letters in electrical circuit diagrams: B (B1, B2, ...)

    BN

    BK

    BU

    +24V

    0V

  • Festo Didactic GmbH & Co. TP 201, Transparency 24

    Magnetic Proximity Sensors (Reed Switches)

    BN

    BK

    BU

    +24V

    0V

  • 25

    Festo Didactic GmbH & Co. Electropneumatics

    Electrical Output Devices

    Supply acoustic signals:

    For example, horns, sirens

    Identifying letters in electrical circuit diagrams: H (H1, H2, ...)

    Supply optical signals:

    For example, lamps, LEDs

    Identifying letters in electrical circuit diagrams: H (H1, H2, ...)

    Do work:

    For example, electric motors

    Identifying letters in electrical circuit diagrams: M (M1, M2, ...)

    M

    Signalling device

    Motors

    Audible indicator:

    Illuminatingindicators:

    Horn

    DC motor

    Lamp Light emitting diode (LED)

    Siren Bell

  • Signalling device

    Motors

    Festo Didactic GmbH & Co. TP 201, Transparency 25

    Electrical Output Devices

    Audible indicator:

    Illuminatingindicators:

    Horn

    DC motor

    Lamp Light emitting diode (LED)

    Siren Bell

    M

  • 26

    Festo Didactic GmbH & Co. Electropneumatics

    The AND Logic Function

    The AND logic function consists of at least two switching elements connected in

    series:

    The AND logic function can have two or more inputs. A combination of switches

    and sensors may be involved.

    The function is represented through a logic symbol with two inputs and one

    output.

    Both input signals must be present to switch the output.

    &

    +24V

    0V

    S2

    H1

    S1

    1

    Output(lamp H1)Input 2

    (S2)

    Input 1(S1)

  • Festo Didactic GmbH & Co. TP 201, Transparency 26

    The AND Logic Function

    OutputInput 2

    Input 1&

    +24V1

    0V

    S2

    H1

    S1

  • 27

    Festo Didactic GmbH & Co. Electropneumatics

    The OR Logic Function

    The OR logic function consists of at least two switching elements connected in

    parallel:

    The OR logic function can have two or more inputs. A combination of switches

    and sensors may be involved.

    The function is represented through a logic symbol with two inputs and one

    output.

    Only one input signal needs to be present to switch the output.

    1

    +24V

    0V

    H1

    S1 S2

    1 2

    Output(lamp H1)Input 2

    (S2)

    Input 1(S1)

  • Festo Didactic GmbH & Co. TP 201, Transparency 27

    The OR Logic Function

    OutputInput 2

    Input 11

    +24V

    0V

    H1

    S1 S2

    1 2

  • 28

    Festo Didactic GmbH & Co. Electropneumatics

    Control Chain

    The structure of the control chain supports:

    The allocation of components with comparable functions to a group of elements.

    The avoidance of lines crossing each other in pneumatic and electrical circuit

    diagrams.

    The preparation of clearly structured and uniformly designed circuit diagrams.

    The principle of the control chain should be understood as being only a guideline.

    The signal flow of the control system defines the structure of the control chain:

    In the pneumatic circuit diagram, the signal flow is represented from bottom to

    top.

    In the electrical circuit diagram, the signal flow is represented from top to

    bottom.

    +24V

    Signalinput

    Sig

    na

    l fl

    ow

    Sig

    na

    l fl

    ow

    Signalprocessing

    Signaloutput

    0V

    S1

    S2

    K1K1

    1Y1

    2

    1 2

    4

    5

    2

    1Y1

    31

    1A

    1V1

  • Festo Didactic GmbH & Co. TP 201, Transparency 28

    Control Chain

    +24V

    Signal input

    Signal processing

    Signal output

    0V

    S1

    S2

    K1K1

    1Y1

    2

    1 2

    4

    5

    2

    1Y1

    31

    1A

    1V1

  • 29

    Festo Didactic GmbH & Co. Electropneumatics

    Direct Actuation of a Single-Acting Cylinder

    After actuating S1, current flows through the coil 1Y1, which switches the valve 1.1.

    Compressed air flows from port 1 to port 2, and the piston rod advances.

    If S1 is no longer actuated, there is no current through coil 1Y1. Valve 1.1 switches

    back into the initial position.

    The cylinder is vented through port 3 of valve 1.1, and the piston rod retracts.

    1Y1

    2

    1Y1

    1A

    1V1

    +24V

    0V

    S1

    1

    1 3

  • Festo Didactic GmbH & Co. TP 201, Transparency 29

    Direct Actuation of a Single-Acting Cylinder

    1Y1

    2

    1Y1

    1A

    1V1

    +24V

    0V

    S1

    1

    1 3

  • 30

    Festo Didactic GmbH & Co. Electropneumatics

    Indirect Actuation of a Double-Acting Cylinder

    The use of indirect actuation depends upon:

    The force which is required for the actuation of the positioner

    The complexity of the circuit

    The switching power of the contacts

    Whether or not the system is remote controlled

    K1 1Y1

    1A

    +24V

    0V

    S1 K1

    1 2

    4

    5

    2

    1Y1

    3

    13

    A1

    A2

    13

    14 14

    1

    1V1

  • Festo Didactic GmbH & Co. TP 201, Transparency 30

    Indirect Actuation of a Double-Acting Cylinder

    1Y1

    1A+24V

    0V

    S1

    1 2

    4

    5

    2

    1Y1

    3

    13

    14

    1

    1V1

  • 31

    Festo Didactic GmbH & Co. Electropneumatics

    Electrical Memory Circuit Dominant Set

    A relay can be held in the switched condition if a holding current path is switched in

    parallel to the ON pushbutton through an internal normally-open contact in the

    relay.

    An OFF pushbutton must be built into the memory circuit. The installed position of

    the OFF pushbutton determines the function of the memory circuit.

    A memory circuit in which a pushbutton (S2, normally-closed) is connected in series

    with a relay holding contact (normally-open) is a dominating set memory circuit.

    In this dominating set memory circuit, the pushbutton S1 dominates the pushbutton

    S2.

    If S1 and S2 are pressed simultaneously, current flows through the relay coil K1.

    +24V

    0V

    S1

    S2

    K1 K1

    2

    3

    1 2 3

    13 23

    14 24

    K1 H1

  • Festo Didactic GmbH & Co. TP 201, Transparency 31

    Electrical Memory Circuit Dominant Set

    +24V

    0V

    S1

    S2

    K1 K1

    K1 H1

    23

    1 2 3

    13 23

    14 24

  • 32

    Festo Didactic GmbH & Co. Electropneumatics

    Electrical Memory Circuit Dominant Reset

    A relay can be held in the switched condition if a holding current path is switched in

    parallel to the ON pushbutton to the relay coil through an internal normally-open

    contact in the relay.

    An OFF pushbutton must be built into the memory circuit. The installed position of

    the OFF pushbutton determines the function of the memory circuit.

    A memory circuit in which a pushbutton (S1, normally-open) and a relay holding

    contact (normally-open) are connected in parallel and then in series with a

    pushbutton (S2, normally-closed) is a dominating reset memory circuit.

    In this dominating reset memory circuit, the pushbutton S2 dominates the

    pushbutton S1.

    If S1 and S2 are pressed simultaneously, no current flows through the relay coil K1.

    +24V

    0V

    S1

    S2

    K1 K1

    2

    3

    1 2 3

    13 23

    14 24

    K1 H1

  • Festo Didactic GmbH & Co. TP 201, Transparency 32

    Electrical Memory Circuit Dominant Reset

    +24V

    0V

    S1

    S2

    K1 K1

    23

    1 2 3

    13 23

    14 24

    K1 H1

  • 33

    Festo Didactic GmbH & Co. Electropneumatics

    Electropneumatic Memory Circuit with Double Solenoid Valve

    Double solenoid valves are also called bistable valves or memory valves:

    The valve illustrated is actuated by two solenoid coils.

    The valve retains the switched position brought about through energising one of

    the coils, even when the signal to switch the valve is cancelled.

    The switched position is reversed only when a signal is applied to the opposite

    coil or a manual override is operated.

    To reverse the switched position, a signal only needs to be applied to one coil.

    1A 1S2

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

  • Festo Didactic GmbH & Co. TP 201, Transparency 33

    Electropneumatic Memory Circuit with Double Solenoid Valve

    1A 1S2

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

  • 34

    Festo Didactic GmbH & Co. Electropneumatics

    Stroke-Dependent Control

    Limit switches with roller lever actuation are frequently used to check the position of

    pneumatic actuators in simple circuits.

    The use of limit sensors in a control depends upon the required accuracy of the

    sensor.

    Decisive factors are:

    The reliability

    The safety

    The complexity of the circuit

    1A 1S21S1

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1S1

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

  • Festo Didactic GmbH & Co. TP 201, Transparency 34

    Stroke-Dependent Control

    1A 1S21S1

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1S1

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

  • 35

    Festo Didactic GmbH & Co. Electropneumatics

    Pressure-Dependent Control

    A pneumatic-electric signal converter measures the air pressure in the supply line of

    cylinder 1A and compares it with a preset value.

    As soon as this value is reached, the signal converter generates an electrical signal.

    1A

    4

    5

    2

    p

    1Y1

    1B1

    1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1 6 7

    K1 K2

    K3

    K1

    5 6 6

    1B2

    1B2 1B1

    p

    2 43 5

    K2 K3

  • Festo Didactic GmbH & Co. TP 201, Transparency 35

    Pressure-Dependent Control

    1A

    4

    5

    2

    p

    1Y1

    1B1

    1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    1 6 7

    K1 K2

    K3

    K1

    5 6 6

    1B2

    1B2 1B1

    p

    2 43 5

    K2 K3

  • 36

    Festo Didactic GmbH & Co. Electropneumatics

    The Electropneumatic Circuit Diagram

    The pneumatic and electrical parts of an electropneumatic circuit diagram are

    prepared separately, but their contents are closely related.

    In the pneumatic part, signal flow is presented from bottom to top.

    In the electrical part, signal flow is presented from top to bottom.

    In the electrical circuit diagram, the current paths are numbered consecutively from

    left to right.

    The common circuit diagram elements form the interfaces between the pneumatic

    and the electrical circuits. In this case, they are the coils 1Y1 and 2Y1, as well as the

    limit sensors 1B1, 1B2, 2S1 and 2S2.

    44

    55

    22

    2Y11Y1

    3311

    2A1A

    2V11V1

    2S21B21B1

    2S1

    1Y1 2Y1

    +24V

    0V

    Start 2S1

    K6 K5

    1B1 1B2

    1 3 5 6 8 10 12 13117 92 4

    2S2K3 K4 K5 K3 K4K2

    K1

    K3 K4 K5

    K1 K2 K3 K4 K5 K6

    5 7 6

    7

    12

    8

    9

    13

    10

    11

    13 5

  • Festo Didactic GmbH & Co. TP 201, Transparency 36

    The Electropneumatic Circuit Diagram

    44

    55

    22

    2Y11Y1

    3311

    2A1A

    2V11V1

    2S21B21B1

    2S1

    1Y1 2Y1

    +24V

    0V

    Start 2S1

    K6 K5

    1B1 1B2

    1 3 5 6 8 10 12 13117 92 4

    2S2K3 K4 K5 K3 K4K2

    K1

    K3 K4 K5

    K1 K2 K3 K4 K5 K6

    5 7 67

    12

    89

    13

    1011

    13 5

  • 37

    Festo Didactic GmbH & Co. Electropneumatics

    Circuit Diagram Structure

    The electropneumatic circuit diagram consists of two parts:

    Pneumatic

    Electrical

    The arrangement of the components follows the signal flow accordingly from

    bottom to top.

    Cylinders and valves are drawn horizontally.

    The outward travel motion of cylinders should be from left to right.

    The arrangement of the components follows the signal flow accordingly from top

    to bottom.

    The electrical circuit diagram can be subdivided into a control part and a power

    part.

    1A

    1V2

    0Z

    1S2

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    Control section Power section

    0V

    S1

    K2

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

    Pneumatic

    Electrical

  • Festo Didactic GmbH & Co. TP 201, Transparency 37

    Circuit Diagram Structure

    1A

    1V2

    0Z

    1S2

    4

    5

    2

    1Y1 1Y2

    31

    1V1

    1Y1 1Y2

    +24V

    0V

    S1

    K2

    1 32 4

    1S2 K1 K2

    K1 K2

    3 4

  • 38

    Festo Didactic GmbH & Co. Electropneumatics

    Displacement-Step Diagram

    In a displacement-step diagram, the motion sequences of an actuator in a control

    system are presented graphically:

    Movements of the cylinder within a step are represented by a line moving

    diagonally upwards (advancing) or downwards (retracting).

    Horizontal lines represent the position of the cylinder in the advanced or

    retracted end position.

    If the movements of several actuators are to be represented, they are arranged

    under each other for every individual step.

    This arrangement clarifies the relationship between the movements of the

    individual actuators in every step.

    1

    0

    1

    0

    1

    Step

    2 3 4 5=1

    1A

    2A

  • Festo Didactic GmbH & Co. TP 201, Transparency 38

    Displacement-Step Diagram

    1

    0

    1

    0

    1

    Step

    2 3 4 5=1

    1A

    2A

  • 39

    Festo Didactic GmbH & Co. Electropneumatics

    Terminal Connection Diagram

    The terminal connection diagram shows the physical implementation of the current

    circuit.

    The identifications used in the circuit diagram are used in the terminal connection

    diagram.

    The terminal points and the cables are numbered. This facilitates the setting-up of

    the controller as well as troubleshooting and maintenance.

    X1-1 X1-2

    3 1

    11 11

    21

    4 2

    14 14

    24

    X1-3 X1-4

    X1-9 X1-12 X1-14

    X1

    X1 14

    15

    14

    20

    13

    19

    12

    18

    11

    17

    10

    16

    9

    8

    7

    6

    5

    4

    3

    2

    1

    1Y1

    K1 114

    3

    +24V

    K2 21

    X1 110V

    K1 A2

    K2 A2

    X1 17

    1B1 X1 1+

    1B1

    1S2

    K1

    K2

    A1

    24

    1B1

    1S2

    X1

    X1

    5

    8

    1Y1

    X1 2S1

    X1 31

    S1

    K2 112

    9

    12X1

    4

    5

    2

    1Y1

    31

    1A

    1V1

    1S21B1

    1Y1

    +24V

    0V

    S1 1S21B1

    1 3 4 52

    K1 K2

    K2

    K1 K2

    3 4

    5

    X1-11

    X1-16

    X1-10

    A1 A1

    A2 A2

    X1-5 X1-8X1-6 X1-7

    X1-13 X1-15

    X1-17

    Connection

    code

    Component

    code

    Co

    mp

    on

    en

    tco

    de

    Connection

    code

    Term

    ina

    l n

    o.

    X1

    Jum

    pe

    r

    Targ

    et

    Targ

    et

    Machine Control cabinet

  • Festo Didactic GmbH & Co. TP 201, Transparency 39

    Terminal Connection Diagram

    X1-1 X1-2

    3 1

    11 11

    21

    4 2

    14 14

    24

    X1-3 X1-4

    X1-9 X1-12 X1-14

    Co

    nn

    ect

    ion

    cod

    e

    X1

    X1 14

    15

    14

    20

    13

    19

    12

    18

    11

    17

    10

    16

    9

    8

    7

    6

    5

    4

    3

    2

    1

    1Y1

    K1 114

    -

    3

    +24V

    Co

    mp

    on

    en

    tco

    de

    Co

    mp

    on

    en

    tco

    de

    Co

    nn

    ect

    ion

    cod

    e

    Term

    ina

    ln

    o.

    X1

    Jum

    pe

    r

    Targ

    et

    Targ

    et

    K2 21

    X1 110V

    K1 A2

    K2 A2

    X1 17

    1B1 X1 1+

    1B1

    1S2

    K1

    K2

    A1

    24

    1B1

    1S2

    X1

    X1

    5

    8

    1Y1

    X1 2S1

    X1 31

    S1

    K2 112

    9

    12X1

    Machine Control cabinet

    4

    5

    2

    1Y1

    31

    1A

    1V1

    1S21B1

    1Y1

    +24V

    0V

    S1 1S21B1

    1 3 4 52

    K1 K2

    K2

    K1 K2

    3 45

    X1-11

    X1-16

    X1-10

    A1 A1

    A2 A2

    X1-5 X1-8X1-6 X1-7

    X1-13 X1-15

    X1-17

  • 40

    Festo Didactic GmbH & Co. Electropneumatics

    Checklist for the Terminal Connection Diagram

    In the preparation of a terminal connection diagram, the structure of the control

    should be checked once again:

    Is every current path connected to the positive +24V bus bar through a terminal?

    Is every current path connected to the negative 0 V bus bar through a terminal?

    Are all external components, such as switches, sensors and valve coils connected

    with one terminal per connection to the current circuit?

    Are all connections to the +24 V and 0 V shown in the terminal connection

    diagram?

    Are all external components included in the terminal connection diagram

    provided with their connection identifications?

    Check all current paths systematically and complete the terminal connection

    diagram.

    Note that not all connections such as the relay contacts, for example must be

    included in the terminal connection diagram.

    Enter all external components with thedesignation of the connection in theterminal connection diagram.

    Systematically check all current pathsand complete the wiring diagram.

    Not all of the connections have to beentered in the wiring diagram(e.g. relay connections are exempt).

    Note:

    Each current path must be connectedto the positive +24 V rail via a terminal.

    Each current path must be connectedto the negative 0 V rail via a terminal.

    External components, such as switches,sensors and solenoids are eachconnected via one terminal per unit.

    Identify the connection point for +24 Vand 0 V in the wiring diagram.

  • Festo Didactic GmbH & Co. TP 201, Transparency 40

    Checklist for the Terminal Connection Diagram

    Each current path must be connectedto the positive +24 V rail via a terminal.

    Each current path must be connectedto the negative 0 V rail via a terminal.

    External components, such as switches,sensors and solenoids are eachconnected via one terminal per unit.

    Identify the connection point for +24 Vand 0 V in the wiring diagram.

    Enter all external components with thedesignation of the connection in theterminal connection diagram.

    Systematically check all current pathsand complete the wiring diagram.

    Not all of the connections have to beentered in the wiring diagram(e.g. relay connections are exempt).

    Note:

  • 41

    Festo Didactic GmbH & Co. Electropneumatics

    Protective Circuits for Inductive Loads

    If the current flowing to an inductive load, for example, a solenoid coil, is

    interrupted, the magnetic field collapses.

    A high induction voltage can be generated which can have the following effects:

    Damage to the coil insulation

    Burning of contacts

    This can be avoided through protective circuits using diodes.

    I1

    I = 01

    I = IM 1

    IM

    I = 0D

    I = ID M

    +24V +24V

    0V 0V

  • Festo Didactic GmbH & Co. TP 201, Transparency 41

    Protective Circuits for Inductive Loads

    I1 I = 01

    I = IM 1 IMI = 0D I = ID M

    +24V +24V0V 0V

  • 42

    Festo Didactic GmbH & Co. Electropneumatics

    Alterable Controls

    Relay-controlled systems are hard wired. The relay control can be replaced in whole

    or in part by a programmable controller.

    The structure of a system that is controlled via a programmable logic controller (PLC)

    is similar to that of a relay-controlled system. Both systems can be subdivided as

    follows:

    Signal input

    Signal processing

    Signal output

    The signal processing part is the part that can be hard wired or freely programmable.

    Switch

    Inputs

    Signalinput

    Signaloutput

    Signal processing

    Relays Contacts

    Outputs

    Program:

    WHEN

    THENOTHERWISE

    WHEN

    THENOTHERWISE

    E0.1

    E0.2

    A0.1

    A0.1

    E0.3

    E0.4

    A0.2

    A0.2

    RESET

    RESET

    AND

    SET

    AND

    SET

    Processor

    S1

    S2

    S3

    S4

    K1

    K2

    K3

    K4

    H1

    H2

    K1 K2

    K3 K4

    + +

    S1

    S2

    S3

    S4

    E1

    E2

    E3

    E4

    H1

    H2

    A1

    A2

    + +

  • Festo Didactic GmbH & Co. TP 201, Transparency 42

    Alterable Controls

    S1

    Switch

    Inputs

    Signalinput

    Signaloutput

    Signal processing

    Relays Contacts

    Outputs

    S2

    S3

    S4

    K1

    K2

    K3

    K4

    H1

    H2

    K1 K2

    K3 K4

    + - + -

    S1Program:

    WHEN

    THENOTHERWISE

    WHEN

    THENOTHERWISE

    E0.1E0.2

    A0.1A0.1

    E0.3E0.4

    A0.2A0.2

    RESET

    RESET

    AND

    SET

    AND

    SET

    S2

    S3

    S4

    E1

    E2

    E3

    E4Processor

    H1

    H2

    A1

    A2

    + -+ -

    Contents