Electrician club with cables
-
Upload
pramod-wattegedara -
Category
Documents
-
view
185 -
download
0
Transcript of Electrician club with cables
Add More to Life with O RANGE
• High impact & Flame Retardant Polycarbonate material• Flame Retardant Nylon Material• High Grade Brass for Terminals, Screws & Components • Phosphor Bronze Socket Contacts• High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011, ISO 9001:2008 Certified Company
My Home (Range - X05/X06/X07/X08)
HOW IT WORKS
My Hotel
• High impact & Flame Retardant Polycarbonate material • Flame Retardant Nylon Material • High Grade Brass for Terminals , Screws & Components • Phosphor Bronze Socket Contacts • High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011,
My Data Center
PIONEER IN MANUFACTURING SRI LANKA’S FIRST OXYGEN FREE CABLE
Why ORANGE Cables• Orange use 99.99% Pure Copper • Oxygen Free Copper• Value addition to the nation through circulation of copper in
house
Features & Benefits of Oxygen free copper
Features BenefitsHigh Conductivity Good ElectricityCorrosion Resistance Long LastingClimate Hardiness Long LastingElongation won't breakeGood Heat Conduction Save Electricity
INDOOR CABLES 0.20 – 50mm
Manufactured to BS - 6500 to a voltage range of 300/500V and 450/750V for wiring in - house and commercial buildings(SLS 733)
UNARMOURED POWER CABLES
Manufactured to BS - 6346 and BS - 5467 to a voltage rating of 600/1000V,for distribution of electricity within cities, factories & buildings. 2C,3C,4C,5C 1.5mm – 16mm
Switchgear CablesManufactured to BS - 6231 to a voltage rating of 600/1000V for wiring of swithgear and controlgear inside control panel 1mm – 50mm
Data CABLES
Telephone Cables 1 to 5 pair, Cat 5e & Cat 6e Cables
AUTO CABLESFlexible copper conductors PVC insulated manufactured for a voltage of 100V. These cables are used for electricle wiring of motor vehicle.
COAXIAL AND RG CABLES
5C2V
3C2V
RG 6
Ensure Circuit Protections with ORANGE
Alfa/Sigma
MCB Functions
Overload protection
Short Circuit protection
o Isolation
Symbol
Tripping lever
Operatingmechanism
Operator
Space foridentificationmarker
Electro-magnetic protection Upperterminal
Thermalprotection bimetal
Arcchamber
Fixedcontact
Movingcontact
DIN rail holderLower terminal
Basic Construction & Normal operating condition
Bi-Metal strip(Thermal)
Electro magnet(Magnetic)
Contacts
Tripping mechanism
Thermal tripping at Overload Condition
Bi-Metal strip(Thermal)
Electro magnet(Magnetic)
Contacts
Tripping mechanism
Magnetic tripping at Short cct Condition
Bi-Metal strip(Thermal)
Electro magnet(Magnetic)
Contacts
Tripping mechanism
Customer Request• Rating (Current Rating)
6A , 10A , 16A , 20A , 25A , 32A , 40A , 63A Also 80A , 100A , 125AStandard Ratings (Corresponding voltage AC/DC & F)
• No of Poles1 P , 2P , 3P , 4P
• CurveB , C , D , ……
• Breaking Capacity4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA),
(Corresponding voltage AC/DC & F)
Tripping Curve(Thermal/Magnetic)
Time
Current multiplesImIr
Over load Short circuit
Tripping curve -B
Tripping curve -C
Breaking Capacity
• It is current that a circuit breaker is capable of breaking at a
given recovery voltage under specified conditions
• The breaking capacity of the circuit breaker must be at least
or equal to the prospective short-circuit current at its point of
installation.
– 4.5KA ,6 KA, 10KA ,15KA- (Up to 50 KA),
RCCB
Residual Current Circuit Breaker
Critical current thresholds
Protection of life and property
Standard IEC 60479-1
Cardiac arrest
Irreversible cardiacfibrillation
Breathing arrest
Muscular contraction
Tingling
1 A
75 mA
30 mA
10mA
0.5 mA
mA
The principle of Residual Current Devices
The principle of Residual Current Devices
Industrial Switch Gears
TV/Fridge/Telephone Socket 6500A
IEC61643-1 Class III
Light Up Life with ORANGE CFL/ LED Technology
• Tri-phosphor coating for high luminous output .
• 8000H life span• All lamps are energy efficiency labeled and
3 star and above.
My Factory
• High quality metal product to withstand adverse conditions • High Quality Powder coated finish • High impact Flame Retardant Polycarbonate material • Flame Retardant Nylon Material • High Grade Brass for Terminals ,Screws & Components • Phosphor Bronze Socket Contacts • High Quality Silver Alloy for Contact Surfaces
Comply with SLS, IEC, EN 60669-1:1999, BS 546:1950, BS 546, SS145, SS 241:1996 , SS 472:1999, SS 241:1996, IEC 60669-1:1999, BS 1363-2:1995, MS 589-2:2011, ISO 9001:2008 Certified Company
Industrial Panel Boards