ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor /...
Transcript of ELECTRICAL VEHICLE CHARGERS...IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact dome lndoor /...
ELECTRICALVEHICLE
CHARGERS
Roaming Networks is one of the leading system integrators in Serbia and the Balkan region. We provide professional consulting, design, implementation, integration and maintenance services in the areas of radio communications, passive optical networks, ICT infrastructure and Data centers and Technical Protection and Automatic Control Systems.
In its portfolio of services, it has also included the provision of ready-made, complete solutions for charging electric vehicles - from compact, high-quality wall chargers for AC charging, reliable DC fast chargers, to innovative charging systems for electric buses on your request. We offer professional consulting, design, implementation, integration and maintenance of vehicle charging systems. We provide and deploy infrastructure that meets the needs of the
new generation of smart mobility, and our goal is to make such mobility
sustainable and accessible to everyone and everywhere.
By introducing innovative solutions for charging electric vehicles and modernizing processes, Roaming Networks has laid the foundation for smart, reliable environmental mobility of vehicles, without emissions and thus confirmed that it is a dynamic and innovative company which
operates responsibly towards society and the environment.
1
General specifications:
1a CAR ChARGERS - AC ChARGERS I Terra AC wall charger
Product information
Charging type
Input/output power rating and current
Input/ouput voltage
Network typeSocket outlet or connector type
Protection
Overvoltage categoryEnergy metering
Mobile communication with nano SIM socketAvailable configurable contacts
Mode 3 charging, level 2 IEC ratings: Single phase up to 7.4 kW / 32 A Three phase up to 22 kW / 32 AUL ratings up to 19 kW / 80 ASingle phase: 110 … 240 VThree phase: 380 … 415 V, 50 / 60 HzTT, TN, ITType 2 socket with or without shutterType 1 or type 2 cable. Cable can be wrapped around the chargerOvercurrent, overvoltage, undervoltage, ground fault including DC leakage protection, integrated surge protectionIIIRevenue grade energy meter Class B (+/- 1%) , MID certification on display variants onlyEU: GSM, 4G, LTE, WCDMA US: 4G, LTE, WCDMA1 input, 1 output
2
General characteristics
Certification and standards
Lifetime
IP and IK rating
NEMA enclosure typeOperating altitudeOperating temperature rangeStorage temperature rangeMountingDimensions H x W x D H x W x D
Safety standards
Codes and standards
CertificationWarranty
10 years. 16 h charging, 8 h standby, 5 charge sessions per dayIP54, IK10 (IK8+ for operating temperature from -35 to -30 °C)NEMA 4 and 4X4000 m-35...+50 °C (derating may apply)-40...+80 °CWall or floor using a pedestal320 x 195 x 110 mm12.60 x 7.68 x 4.33 inches
IEC/EN 61851-1, IEC/EN 62311, IEC/UL 62479, IEC/UL 62955TuV listed conforming to UL 2594, UL 2231-1, UL 2231-2, UL 1998, CSA C22.2. NO.280IEC 61851-21-2, EN 61000 -6 -1, EN 61000 -6 -2, EN 61000 -6 -3, EN 61000 -6 -4, EN 61000 -3-2, EN 61000 -3-3, EN 61000 -3-11, EN 61000 -3-12CE RED - WL AN / RFID / E-UTR A: EN 300 328 V2.1.1, EN 300 330 V2.1.1, EN 301 908-1 V11.1.2, EN 301 908-13FCC Part 15 Class BENERGY STARCE, CB, MID, UL24 months
3
Technical specification:
1bProduct information
DC output powerDC output voltageDC output currentUser interfaceRFID system
Network connection
EnvironmentOperating temperature
ProtectionDimensions (H x W x D)Charge cableMass
24 kW peak - 22.5 kW continuous150 - 920 VDC
60 A7” full color touchscreen displayISO/IEC14443A/B, ISO/ IEC15693,NFC reader mode, Mifare, CalypsoGSM / 3G modem10/100 Base-T EthernetIndoor / outdoor-35 °C to +55 °C(de-rating characteristic applies)IP54, indoor and outdoor770 x 584 x 300 mmcable lengths 3.5 or 7 m60kg excluding backplate(10 kg) and cables
4
CAR ChARGERS - DC ChARGERS I Terra DC wallbox 24 DC
CE models
Charging protocols
AC Input power connectionInput voltage rangeMax. rated input current
Efficiency
Compliance and safety
CCS 2CHAdeMO3P + N + PE400 VAC +/-10 % (50/60 Hz)3 x 40 ACurrent limiting options available94 % at nominal outputpowerCEEMC Class A today,EMC Class B Q3 2019
5
Technical specification:
Optional models: Terra 94 DC/ Terra 124 DC/ Terra 184 DC
CAR ChARGERS - DC ChARGERS I Terra 54 DC
General specifications
Grid Interface
Charging sessions
EfficiencyEMC emissionEMC immunityEnvironment of useProtection ratingOperating temperatureDimensions (D x W x H)Mass
Input AC power connectionInput voltage rangeMax. rated input current &power (@ 50 Hz)
Power factor (full load)THD in all operating pointsOperating Noise level
1 DC session1 DC & 1 AC session (G & T models)94 % at nominal output powerIEC 61000-6-3 Class B - ResidentialIEC 61000-6-2 IndustrialIndoor / outdoorIP54, IK10 (cabinet), IK8 (screen)-35 °C to +55 °C (de-rating characteristics apply)780 mm x 565 mm x 1900 mm350 kg
3 Phases + Neutral + PE400 V
AC +/- 10 % (50 Hz or 60 Hz)C, CJ : 80 A, 55 kVACT, CJT : 112 A, 77 kVACJG, CG : 143 A, 98 kVA> 0.96< 4.5 %< 60 dBA
6
User & Network Interfaces
Options
Outlet specifications C (default) J (option) G (option) T (option)
ScreenRFID systemNetwork connection
Communication protocol
Local payments
Power meterCable management system
Charging standardMaximum output powerOutput voltage Terra 54Output voltage Terra 54HVMaximum output currentConnector/socket typeCable length
CCS
50 kW
150 - 500 VDC
150 - 920 VDC
125 ADC
CCS 2 / IEC 62196 Mode-4
3.9 m
CHAdeMO 2.0
50 kW
150 - 500 VDC
150 - 500 VDC
125 ADC
CHAdeMO 2.0 / JEVS G105
3.9 m
Type 2 cable
22 or 43 kW
400 V +/- 10%
400 V +/- 10%
63 A
IEC62196 Mode-3 Type-2
3.9 m
Type 2 socket
22 kW
400 V +/- 10%
400 V +/- 10%
32 A
IEC62196 Mode-3 Type 2
7” touchscreenISO/IEC 14443A/B, ISO/IEC 15393Cellular modem: GSM / 3G / 4G LAN: 10/100 Base-T EthernetOpen Charger Point Protocol (OCPP) 1.6(and previous versions)
Credit Cards and NFC (including Apple Pay)readerDC & AC certified metersCharger prepared for CMS installation
7
Technical specification:
CAR ChARGERS - DC ChARGERS I Terra HP
General specifications
Charge post
Compliance and certificationEnvironmentMechanical impact protectionOperating temperature
DC output current
DC output voltage rangeUser interfaceLights
RFID
Network connections
Dimensions (H x W x D)Weight
CE models and UL models availableIP 54, outdoor useIK 10 (screen: IK 08)-35 °C to +55 °C (with derating)
500 A CCS (liquid cooled)200 A CHAdeMO150 – 920 V
DC
7” high brightness touch screenRGB led strips with customizable colors White top lightISO/IEC 14443A/B, ISO/IEC 15393,FeliCa™1, NFC, Mifare, Calypso, (option: Legic)GSM/2G/3G10/100 base-T Ethernet2390 x 620 x 440 mm250 kg
8
Power cabinet
Output power per power cabinet
AC Input – CE models
AC Input – UL models
Efficiency (full load)Power factorEMC emission
Dimensions (H x W x D)Weight
175 kW peak160 kW continuous (375 A)400 VAC ±10%, 50 Hz3P + PE (no neutral)277 A nominal @400 VAC
(160 kW output)308 A peak @360 VAC
(175 kW output)480 VAC ±10%, 60 Hz3P + PE (no neutral)215 A nominal @480 VAC
(160 kW output)272 A peak @432 VAC
(175 kW output)≥ 94% at full load≥ 0.97Standard: Class A (industrial)Optional: Class B (residential)with external filter2030 x 1170 x 770 mm1340 kg
175 kW 375 A150-920 VDC
9
Connector specification:
1c
Technical specifications
PowerInput AC connectionRated input current & power (per 150 kW module)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature
Dimensions (W,D,H)
100 kW, 150 kW3P + PE100 kW: 3 x 170 A, 117 kVA150 kW: 3 x 250 A, 173 kVA400 V
AC +/-10% (50 Hz or 60 Hz)100 kW: 166 A150 kW: 200 A (limited by CCS cable)150- 850 V DC
IEC 61851-23 / DIN 70121/ ISO 15118CCS 1 or CCS 2lndoor / OutdoorStandard: -10 °C to +SO °C Optional: -35 °C to + 50 °CPower cabinet: 1170 x 770 x 2030 mmDepot eh arge box: 600 x 220 x 800 mm
CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model - HVC 100C/150C
10
Technical specifications
Network connection
Protection
Sequential chargingCable length between depot charge box and cabinetCable length between 2 depot charge boxesCable length connector
GSM / 3G modern10/100 base-T EthernetCharge cabinet: IP54- IK10Depot charge box: IP65- IK10Yes, up to 3 outlets per chargerUp to 150 m
Up to 30 mStandard: 3.5 mOptional: 7 m
11
12
Technical specification:
Pantograph Down Specification – Overnight & Opportunity Charging
CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model HVC 150PD/300PD/450PD/600PD
General specifications
PowerInput AC connectionRated input current & power (per 150 kW power cabinet)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature
Dimensions (W,D,H)
Network connection
Protection
150 kW, 300 kW, 450 kW, 600 kW 3P + PE3x 250 A, 173 kVA
400 V AC +/- 10% (50 Hz or 60 Hz)
250 AMax is 600 A (limited by pantograph)150-850 V DC
IEC 61851-23 / OppCharge4-pole automatic connection systemlndoor / OutdoorStandard:-10 °C to +50 °C Optional: -35 °C to + 50 °CPower cabinet : 1170 x 770 x 2030 mmPole: 4850 x 1060 x 5820 mmGSM / 3G modern10/100 base-T EthernetIP54- IK10
13
Technical specification:
Pantograph Up Specification – Opportunity Charging
CHARGERs fOR HEAVy COmmERCIAL VEHICLEsI model - HVC 150PU/350PU/450PU/600PU
General specifications
PowerInput AC connectionRated input current & power (per 150 kW power cabinet)Input voltage rangeMaximum output current (per 150 kW power cabinet)Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature
Dimensions (W,D,H)
Network connection
ProtectionCable length between power cabinet and pole
150 kW, 300 kW, 450 kW, 600 kW 3P + PE3x 250 A, 173 kVA
400 V AC +/- 10% (50 Hz or 60 Hz)
250 AMax is 600 A (limited by contact hood)150-850 V DC
IEC 61851-23 / DIN 70121/ ISO 15118 4-pole contact domelndoor / OutdoorStandard: -10 °C to +50 °C Optional: -35 °C to + 50 °CPower cabinet : 1170 x 770 x 2030 mmPole: 4850 x 1060 x 5820 mmGSM / 3G modern10/100 base-T EthernetIP54- IK10Up to 100 m
14
Technical specification:
Pantograph Up Specification – Overnight Charging
General specifications
PowerInput AC connectionRated input current & power
Input voltage rangeMaximum output current
Output voltage rangeDC connection standardConnection method between charger and busEnvironmentOperating temperature
Dimensions (W,D,H)
Network connection
Protection
Sequential charging Cable length between power cabinet and contact domeCable length between 2 contact domes
50 kW, 100 kW, 150 kW 3P + PE50 kW: 3x 80 A, 55 kVA100 kW: 3x 170 A, 117 kVA150 kW: 3x 250 A, 173 kVA400 V
AC +/-10 % (50 Hz or 60 Hz)50 kW: 125 A100 kW: 166 A150 kW: 250 A150- 850 V DC
IEC 61851-23 / DIN 70121/ ISO 151184-pole contact domelndoor / OutdoorStandard:-10 °C to +50 °C Optional: -35 °C to + 50 °C50 kW power cabinet: 325 mm x 770 mm x 1300 mm100-150 kW power cabinet: 1170 x 770 x 2030 mmControl box: 600 x 600 x 250 mmGSM / 3G modern10/100 base-T EthernetCharge cabinet: IP54-IK10Control box: IP65-IK10Yes, up to 3 outlets per chargerUp to 150 mUp to 30 m
15
16
General specifications:
CAR ChARGERS - AC ChARGERS I sicharge CC AC22
Product information
Charging connections
EfficiencyCharging processes
Environment of useProtection ratingOperating temperatureDimensions (H x D x W)MassInput AC power connectionInput voltage rangeMax. rated input current &power (@ 50 Hz)
DisplayRFID systemNetwork connectionCommunication protocol
AccountingPower meterFlexible connected load
2 x AC 22 kW, type 294 % at nominal output powerCharging mode according to IEC 61851 “Mode 3”, charging current regulationIndoor / outdoorIP54, IK10-25 °C to +50 °C1700 mm x 390 mm x 194 mm75 kg3 Phases + Neutral + PE230/400 V
AC, 50 Hz, 63AMain switch with fuses 63A, 3P+NMCB, 2x32A, 3P+N B type RCD, In 30 mA, with monitoring functionTFT LED 7“ color with pushbuttonISO 14443Connection via GPRS, UMTS and LTEOpen Charger Point Protocol (OCPP) 1.6(and previous versions)Accounting possible via backend systemBasic MID meterStatic load managementBackend-side load management (OCPP 1.6)
17
2a
General specifications:
CAR ChARGERS - DC CHARGERs I CPC 50
Product information
Charging connections
EfficiencyNoise level(at full load)Environment of useProtection ratingOperating temperatureDimensions (H x D x W)MassInput AC power connectionAC Input voltage rangeAC Input current Power consumedRelative humidity
Authentication
CCS 50kW, CHAdeMO 50kW, AC 22kW type 2>94 %<55 dB
Indoor / outdoorIP54-30 °C to +50 °C1929 mm x 822 mm x 618 mmapprox. 650 kg 3 Phases + PE400 V
AC ± 10%3 x 150 AAC <130 W 5% to 95%(without condensation)RFID/NFC Reader/Writer
18
2b
Product information
Network connection
Communication protocol
AccountingPower factor (50% load)AC output power
AC output voltageAC output currentDC output power
DC output voltage
DC output currentPayment systems
Ethernet, GSM, GPRS, UMTS (3G modem), LTE 4GOpen Charger Point Protocol (OCPP) 1.5(1.6 and 2.0 in preparation)Backend-side load management (OCPP 1.6)Accounting possible via backend system>97%22 kW/43 kW, IEC 62196 Mode 3, Type 2400 V
AC ± 10%3 x 32 AAC / 3 x 63 AAC
50 kW(CCS or CHAdeMO)920 VDC
(as of 850 V with derating)125 AISO 14443 A/B, Mifare,ISO 18092 (NFC),DESFire, FeliCA Mobile App
19
20
General specifications:
CHARGERs fOR ELECTRIC HEAVy COmmERCIAL VEHICLEsI sicharge UC – Charging Center
Product information
Power, kWInput AC connectionCurrent at nominal voltage per phase, AInput voltage rangeMaximum output current,APeak power, kWOutput voltage rangeOperating temperature Power factor cos phiEnvironmentCharging standardsEMC standardsDimensions (W,D,H), mApprox. weight, kgNetwork connectionCommunication protocolProtection
** Complies with ISO15118-1 standard use-cases, further use-cases being implemented
50, 100, 150, 225, 300, 450, 6003P + PE76, 152, 228, 342, 456, 683, 911400 V AC +/- 10% (50 Hz or 6063, 125, 200, 300, 400, 600, 80063, 125, 200, 300, 400, 600, 80010-1000 V DC
-25 °C to +45 °C, extended upon request>0,98lndoor / OutdoorEN 61851-1/23/24, ISO 15118 (DIN 70121)**EN 55016-2-1 & -3; EN 61000-4-2 & -3 & -4 & -5 & -60,7x0,8x1,8; 0,91x1,0x2,0; 1,4x1,0x2,0; 2,4x1,0x2,0; 2,8x1,0x2,0700, 1000, 1400, 2000, 2600, 4000, 5200Ethernet / 3G and 4G / WLANOCPP 1.6 (J-SON)IP54- IK10
21
General specifications:
Product information
Rated power standard, peak, liquid-cooled cable option, kWInput connectionRated input current & powerFrontend, Pantograph, HoodOutput current, AOutput (max. liquid cooled cable) current, (option), AOutput voltage rangeOperating range Pantograph, mm Material FrontendInv. pantograph / HoodHeight, installed, mm Cantiliver length, mmCommunication standardProtectionNumber of possible connectors (sequential charging)
150, 200 peak, 500 peak l-c option/600, 800 pea. /600, 800 pea.3P + PEFrom Charging CenterFully preinstalled, Electrically checked and equipped150 / 600 / 600500 / - / - 10-1000 V
DC Gal.steel powder coated/Gal.steel fib. glass panel/Gal.s painted RAL 9006 White alu.; 9017 Black matt / RAL 9006 White alu.With CCS cableUrban-industrial (extended) design/Industrial - T-shape design1765 / 5805-6576 / 5000 - / 3955-422-5200 / 3500-7000PLC / WiFi IEEE 802.11a / PLCIP54- IK10up to 5 / 1 / 2
CHARGERs fOR ELECTRIC HEAVy COmmERCIAL VEHICLEsI sicharge UC – Dispenser / Inverted Pantograph / mast mounted Hood
22
23
General specifications:
CAR ChARGERS - AC ChARGERS I EVlink Wallbox
Product information
Power per connector
Mounting
Charging connector
Environment of useProtection ratingOperating temperatureDimensions (H x W x D)MassPower supplyInput voltage rangeInput current, *Circuit breaker (overcurr.) *RCD (residual curr.)
*The charger operates autonomously. It has a dedicated protective device.
AC 3.7/7.4/22 kW; shuko/type 2Wall / FloorSocket outlet/domesticsocket option (TE)/attached cableIndoor / outdoorIP54, IK10-30 °C to +50 °C480 mm x 331,5 mm x 170 mm5,6 – 7,9 kg1 Ph. 3,7-7,4 kW; 3 Ph. 11 – 22 kW240/415 V
AC, 50/60 Hz16/32 A 20/40 A Curve C30 mA B Type
AuthenticationNetwork connectionCommunication protocol AnntenaEarthing systemEnergy metering
Key lock or RFID user authenticationWired Eth. 3 ports (LAN,WiFI,3G/4G, conn. to PC); Wi-Fi module or 3G/4G modem-accessoryMust be ordered separatelyTT, TN-S, TN-C-SIntegrated measuring of the apparent powerInterface with an external MID energy meter
3a
24
General specifications:
CAR ChARGERS - DC CHARGERI EVlink DC Parking
Product information
ConnectorMountingCharging voltage/current
Environment of useProtection ratingOperating temperatureDimensions (H x W x D)MassPower supplyInput voltage rangeInput current, *Circuit breaker (overcurr.) *RCD (residual curr.)
Authentication
Network connectionCommunication protocolAnntenaEarthing systemEnergy metering
*The charger operates autonomously. It has a dedicated protective device.
7.4/22 kW per connector Wall / FloorWall mounted / Floor standingMode 3 with T2 or T2 with shutter socket outlet (T2/T1) regulationIndoor / outdoorIP54 (IEC 60529), IK10 (IEC 62262)-25 °C to +50 °C 413 (1146) mm x 413 mm x 220 (256) mm33-50 kg7,4 kW 220/240 V 1P+N or 22 kW 380/415 V 3P+N220-240/380-415 V
AC, 50/60 Hz10 A - 32 A 16/40 A Curve C30 mA B Type
RFID authentication; Mifare Ultralight, Mifare Classic 1K / 4K, I Code SLI, Tag-it HFITCP/IP; FTP, SMTP or HTTP data retrievalOpen Charger Point Protocol (OCPP) 1.5 or 1.6) Must be ordered separatelyTT, TN-S, TN-C-SIntegrated measuring of the apparent powerInterface with an external MID energy meter
3b
25
General specifications:
CAR ChARGERS - DC CHARGERs EVlink DC fast Charge
Product information
ConnectorMountingCharging voltage/current
Environment of useProtection ratingOperating temperatureCharging powerMassPower supplyRelative humidityProtection
Communication
User interfaceCommunication protocolOperating altitudeCable lengthDimensions
DC CCS, CHAdeMO +AC typeWall / Floor150 to 530 V
DC / 1.5 to 65 A400 V ± 10% AC / 32 A maxIndoor / outdoorIP54, IK10-25 °C to +50 °C 24 kW DC; 22 kW AC
66 – 85 kg380 - 480 V, 3P+N+Earth, 50/60 Hz10% to 95%Against short circuit, overload; protected against overheating,temperature regulatedWireless 3G modem; LAN/TCP IP protocolRFID user authentication; 7-inch touch screenOpen Charger Point Protocol (OCPP) 1.5 or 1.6)2000 m max.3,25 mWall mounted:H 860 x L 507 x W 250 mmMono on pedestal: H 1533 x L 536 x W 336 mmMulti on pedestal: H 1835 x L 536 x W 336 mm
ROAMING NETWORKS I Oblakovska 51, 11000 Belgrade, Serbia
office +381 11 7854 74 I fax +381 11 7854 725 I www.roamingnetworks.com