Electrical testers from Megger

2
Electrical testers from Megger Megger Limited Archcliffe Road Dover CT17 9EN UK T +44 (0) 1304 502100 F +44 (0) 1304 207342 E [email protected] Megger SARL 23 rue Eugène Henaff ZA du Buisson de la Couldre 78190 TRAPPES FRANCE T +33 (0)1 30 16 08 90 F +33 (0)1 34 61 23 77 E [email protected] Megger PO Box 10044 Edingien 1613 Johannesburg SOUTH AFRICA T +27 11 4526287 F +27 11 6096852 E [email protected] Megger PO Box 15777 Kingdom of BAHRAIN T +973 17 411311 F +973 17 413399 E [email protected] Part no. 21500-0xx_en_V01 Printed in England 0306 Megger MIT200 range ultra-weight insulation and continuity testers Conforms to IEC 61557-1, 2 and 4 Compact, can be slipped into a pocket Colour coded function selection Intelligent Safety System for protection Megger MIT300 range ultra-weight insulation and continuity testers for electricians Conforms to IEC 61557-1, 2 and 4 Extremely easy to use Clear function selection Tough rubber armoured case Intelligent Safety System for protection Switched probe option Weather and dust proof to IP54 Supplied with calibration certificate Insulation testing MIT200 MIT210 MIT220 MIT230 MIT310 MIT310A MIT320 MIT330 250 V 500 V 1000 V Test range 1000 M Ω 1000 M Ω≈ 1000 M Ω≈ 1000 M ≈≈ 1000 M ≈≈ 1000 M ≈≈ 1000 MΩ≈ 1000 MΩ Insulation limit alarm Continuity from 0.01 Ω to 100 Ω Lead null 9.99 Ω Ω Default voltmeter Data storage and downloading Category CAT III CAT III CAT III CAT III CAT IV CAT IV CAT IV CAT IV 600 V 600 V 600 V 600 V 300 V 300 V 300 V 300 V FREE calibration certificate Megger products will enable testing of electrical installations to the following standards. Australia AS3000:2000 Austria ÖVE/ÖNORM E8001 Belgium A.R.E.I. Denmark Stærkstrømbekendtgørelsen 6 Europe ES 59009 Cenelec Harmonised Document 384 Finland SPS 6000 France NFC 15-100 Germany DIN VDE 0100, 0105 Italy CEI 64-8 Netherlands NEN 3140, 1010 New Zealand NZS 3000:2000 Norway NEK 400 Portugal RIUEE - Dec. Lei 740/74 Spain UNE 20460 South Africa SABS 0142 Sweden SS 4364661 / ELSAK-FS 1995 Switzerland NIV / SN SEV 1000 UK BS7671 16th Edition IEE Wiring Regulations World IEC 60364 The word ‘Megger’ is a registered trade mark Megger MFT range of multi function installation testers Testing to EN61557 –2, 3, 4 and 6 Combined insulation, continuity, earth loop impedance and RCD tester Easy to use Tough rubber armoured 3-phase safe Intelligent safety system Megger LRCD220 combined loop and RCD tester Testing to EN61557 – 3 and 6 Working voltage from 110 V to 230 V 3-phase safe Easy to use Megger LT320 and LT303 earth loop impedance testers Testing to EN61557 – 3 No trip testing 3-phase safe Displays potential fault current PFC Megger LT300 earth loop impedance testers Testing to EN61557 – 3 High current tripping testing 3-phase safe CAT IV 300 V Megger RCDT300 range of RCD testers Testing to EN61557 – 6 Tests standard, d.c. and selective RCDs Accurate readout of tripping time Displays contact voltage Megger DLRO range of low resistance ohmmeters Small light weight and easy to use Multiple operating modes including fully automatic Automatic current reversal cancels standing emfs CATIII 600 V 250 V, 500 V and 1000 V insulation testing Continuity from 0.01 Ω to 100 Ω High current earth to line and line to line loop impedance testing Low current no trip loop impedance testing PSC measurement Testing of 10, 30, 100, 500, 1000 mA RCDs RCD trip current test – ramp test Automation RCD testing Contact voltage Backlight and illuminated range knobs Illuminating probe Downloading MFT1501 E MFT1502 E MFT1552 E LRCD220 LT300 LT320 LT330 RCDT320 RCDT330 Measurement range 0.1 Ω to 1999.9 Ω 0.1 Ω to 1999.9 Ω Resolution 0.1 Ω 0.1 Accuracy 0.2% 0.2% Current test range 0.1 mA to 10 A 0.1 mA to 10 A Results storage Downloading via RS232 port Weight excluding test leads 2.6 kg 2.6 kg DLRO 10 DLRO 10 X

Transcript of Electrical testers from Megger

Page 1: Electrical testers from Megger

Electrical testers from Megger

Megger LimitedArchcliffe Road DoverCT17 9ENUKT +44 (0) 1304 502100F +44 (0) 1304 207342E [email protected]

Megger SARL23 rue Eugène HenaffZA du Buisson de la Couldre78190 TRAPPESFRANCET +33 (0)1 30 16 08 90F +33 (0)1 34 61 23 77E [email protected]

MeggerPO Box 10044 Edingien1613 JohannesburgSOUTH AFRICAT +27 11 4526287F +27 11 6096852E [email protected]

MeggerPO Box 15777Kingdom of BAHRAINT +973 17 411311F +973 17 413399E [email protected]

Part

no

. 215

00-0

xx_e

n_V

01 P

rin

ted

in E

ng

lan

d 0

306

Megger MIT200 range ultra-weight insulation and continuity testers

■ Conforms to IEC 61557-1, 2 and 4■ Compact, can be slipped into a pocket■ Colour coded function selection■ Intelligent Safety System for protection

Megger MIT300 range ultra-weight insulation and continuity testers for electricians

■ Conforms to IEC 61557-1, 2 and 4■ Extremely easy to use■ Clear function selection■ Tough rubber armoured case■ Intelligent Safety System for protection■ Switched probe option■ Weather and dust proof to IP54■ Supplied with calibration certificate

Insulationtesting MIT200 MIT210 MIT220 MIT230 MIT310 MIT310A MIT320 MIT330

250 V ■ ■ ■ ■ ■ ■

500 V ■ ■ ■ ■ ■ ■ ■

1000 V ■ ■ ■ ■ ■

Test range 1000 M Ω 1000 M Ω≈ 1000 M Ω≈ 1000 M ≈≈ 1000 M ≈≈ 1000 M ≈≈ 1000 MΩ≈ 1000 MΩ≈Insulation limit alarm ■ ■

Continuity from0.01 Ω to 100 Ω ■ ■ ■ ■ ■ ■ ■ ■

Lead null 9.99 Ω ■ ■ ■ ■ ■ ■ ■ ■

ΩDefault voltmeter ■ ■ ■ ■ ■ ■ ■ ■

Data storage and downloading ■

Category CAT III CAT III CAT III CAT III CAT IV CAT IV CAT IV CAT IV600 V 600 V 600 V 600 V 300 V 300 V 300 V 300 V

FREE calibrationcertificate ■ ■ ■ ■ ■ ■ ■ ■

Megger products will enable testing of electrical installations to the

following standards.

Australia AS3000:2000

Austria ÖVE/ÖNORM E8001

Belgium A.R.E.I.

Denmark Stærkstrømbekendtgørelsen 6

Europe ES 59009 Cenelec Harmonised

Document 384

Finland SPS 6000

France NFC 15-100

Germany DIN VDE 0100, 0105

Italy CEI 64-8

Netherlands NEN 3140, 1010

New Zealand NZS 3000:2000

Norway NEK 400

Portugal RIUEE - Dec. Lei 740/74

Spain UNE 20460

South Africa SABS 0142

Sweden SS 4364661 / ELSAK-FS 1995

Switzerland NIV / SN SEV 1000

UK BS7671 16th Edition IEE Wiring Regulations

World IEC 60364

The word ‘Megger’ is a registered trade mark

Megger MFT range of multi functioninstallation testers

■ Testing to EN61557 –2, 3, 4 and 6■ Combined insulation, continuity, earth

loop impedance and RCD tester■ Easy to use ■ Tough rubber armoured ■ 3-phase safe■ Intelligent safety system

Megger LRCD220 combined loop andRCD tester

■ Testing to EN61557 – 3 and 6■ Working voltage from 110 V to 230 V■ 3-phase safe■ Easy to use

Megger LT320 and LT303 earth loopimpedance testers

■ Testing to EN61557 – 3■ No trip testing■ 3-phase safe■ Displays potential fault current PFC

Megger LT300 earth loop impedancetesters

■ Testing to EN61557 – 3■ High current tripping testing■ 3-phase safe■ CAT IV 300 V

Megger RCDT300 range of RCD testers

■ Testing to EN61557 – 6■ Tests standard, d.c. and selective RCDs■ Accurate readout of tripping time■ Displays contact voltage

Megger DLRO range of low resistanceohmmeters

■ Small light weight and easy to use■ Multiple operating modes including fully

automatic■ Automatic current reversal cancels

standing emfs ■ CATIII 600 V

250 V, 500 V and 1000 V insulation testing ■ ■ ■

Continuity from 0.01 Ω to 100 Ω ■ ■ ■

High current earth to line and line to line loop

impedance testing ■ ■ ■ ■ ■ ■ ■

Low current no trip loop impedance testing ■ ■ ■ ■ ■ ■

PSC measurement ■ ■ ■ ■

Testing of 10, 30, 100, 500, 1000 mA RCDs ■ ■ ■ ■ ■ ■

RCD trip current test – ramp test ■ ■ ■ ■ ■ ■

Automation RCD testing ■ ■ ■ ■

Contact voltage ■ ■ ■ ■ ■ ■

Backlight and illuminated range knobs ■ ■ ■ ■ ■ ■ ■

Illuminating probe ■ ■

Downloading ■ ■

MFT

1501 E

MFT

1502 E

MFT

1552 E

LRC

D220

LT300

LT320

LT330

RC

DT3

20

RC

DT3

30

Measurement range 0.1 Ω to 1999.9 Ω 0.1 Ω to 1999.9 Ω

Resolution 0.1 Ω 0.1 ≈

Accuracy 0.2% 0.2%

Current test range 0.1 mA to 10 A 0.1 mA to 10 A

Results storage ■

Downloading via RS232 port ■

Weight excluding test leads 2.6 kg 2.6 kg

DLR

O 1

0

DLR

O 1

0 X

Page 2: Electrical testers from Megger

Megger DET20C downloading groundresistance clamp testers

■ Large jaw opening■ Automatic self calibration■ Auto ranging■ High and low alarms■ Downloading to USB port

Megger AVO300 multimeters

■ Tough■ Easy to use■ Ideal for electricians

Megger MIT400 range of industrial maintenance insula-tion and continuity testers

■ Conforms to EN61557-1, 2 and 4■ CATIV 600 V■ True RMS and d.c. voltage measurement■ 50 V live circuit warning■ Variable continuity current■ Switched probe option■ Weather and dust proof to IP54■ Supplied with calibration certificate

Megger MIT480 range of telecommunications insulationand continuity testers

■ Conforms to EN61557 – 1, 2 and 4■ CATIV 600 V■ True RMS and d.c. voltage measurement■ 75 V live circuit warning■ Variable continuity current■ Switched probe option■ Weather and dust proof to IP54■ Supplied with calibration certificate

EARTH ELECTRODE TESTING

Megger DET3TA analogue display three pole earth testing kit

■ Convenient to use■ Automatically carries out pre-test checks■ Weather and dust proof to IP54■ Comes complete with stakes and wires

Megger DET3TD digital display three pole earth testing kit

■ Convenient to use■ Automatically carries out pre-test checks■ Weather and dust proof to IP54■ Comes complete with stakes and wires■ Includes a FREE calibration certificate

Megger DET3TC Attached rod technique enabled digital display three pole earth testing kit

■ Used with optional ICLAMP allows fall of potential testing without disconnecting the electrode under test

■ Convenient to use■ Automatically carries out pre-test checks■ Weather and dust proof to IP54■ Comes complete with stakes and wires■ Includes a FREE calibration certificate

Megger M7000 and M8000 high specification multimeters

■ Highly accurate■ Dual display ■ Ideal for those needing

that bit more

Megger DCM digital clamp meter

■ Easy to use■ Non intrusive■ Multifunction■ Classic design

Megger MMC850 multi-core clamp meter

■ Measure current withoutsplitting the cable

■ 5 cable formats

Megger VF1voltage detector and torch

■ Quick easy methodto check for a.c. voltage

Voltage range V a.c. 600 600 750 750 750 750V d.c 600 600 1000 1000 1000 1000V a.c. and d.c.Accuracy 1% 1% 0,3% 0,2% 0,08% 0,08%

a.c. conversion type Average responding ■ ■ ■ ■ ■ ■

True RMS

Current range A a.c.A d.c. 10 10 10 10 10 10

10 10 10 10 10 10

Resistance Ω 20 M 20 M 40 M 40 M 40 M 40 M

Continuity Audible buzzer ■ ■ ■ ■ ■ ■

Diode ■ ■ ■ ■ ■ ■

Conductance nS 400 400 400 400

Capacitance mF 40 40 40 40

Frequency Hz 250 k 250 k 4 M 4 M

Display Single parameter ■ ■

Dual parameterNumber of digits 31/2 31/2 43/4 & 33/4 43/4 & 33/4 43/4 & 33/4 43/4 & 33/4Bar graph ■ ■ ■ ■

Backlit ■

Operation Auto ranging ■ ■ ■ ■ ■ ■

Data hold ■ ■ ■ ■ ■ ■

Max / min record ■ ■ ■ ■ ■

Relative function ■ ■ ■ ■

Protection Rubber boot ■ ■ ■ ■ ■ ■

Weather proof to IP44 ■ ■

Current range A a.c. 600 1000 2000 1000 2000 30 mA to 300 A 100 A multi core

A d.c. 1000 200 1000 2000 200 A single core

Voltage range V a.c. 600 600 600 600

V d.c. 600 600 600 600

Resistance Ω ■ ■ ■ ■ ■

Continuity Audible buzzer ■ ■ ■ ■

Frequency kHz ■

Display Number of digits 31/2 31/2 31/2 31/2 31/2 31/2 31/2

Backlit ■

Operation Data hold ■ ■ ■ ■ ■ ■ ■

Max conductor size (mm) 40 51 50 50 50 40 13

Core cable Single core ■ ■ ■ ■ ■ ■ ■

Multi core ■

Stakeless testing ■ ■

2-wire testing ■ ■ ■ ■

3-wire testing ■ ■ ■ ■

4-wire testing ■

Attached rod technique (ART)

testing with optional ICLAMP ■

Resistance range 0,01 to 0,01 to 0,01 to 0,01 to 0,025 to 0,025 to

2,0 kΩ 2,0 kΩ 2,0 kΩ 2,0 kΩ 1,5 kΩ 1,5 kΩ

Earth voltage range0 to 100 V 0 to 0 to 0 to 100 V 100 V 100 V

Earth current with optional clamp 0,5 mA to 0,2 mA to 0,2 mA to 19,9 A 35,0 A 35,0 A

Display analogue digital digital digital digital digital

Downloading ■

Safety Cat IV Cat IV Cat IV Cat IV Cat IV100 V 100 V 100 V 100 V 100 V

FREE calibration certificate ■ ■ ■ ■ ■

Industrial maintenanceinsulation and continuity testers

250 V, 500 V and 1000 V insulation test ■ ■ ■ ■

50 V and 100 V insulation test ■ ■ ■

Resistance to 20 GΩ 100 GΩ 200 GΩ 200 GΩ

Continuity 0.01 to 200 Ω ■ ■ ■ ■

Polarization Index PI ■ ■ ■

Dielectric absobption rate DAR ■ ■ ■

Frequency measurement ■ ■ ■

Capacitance measurement ■ ■

Data storage ■ ■

Bluetooth downloading ■

Safety Cat IV Cat IV Cat IV Cat IV

600 V 600 V 600 V 600 V

FREE calibration certificate ■ ■ ■ ■

Telecommunicationsinsulation and continuity testers

250 V, 500 V and 1000 V insulation test ■ ■

50 V and 100 V insulation test ■ ■ ■

Resistance to 100 GΩ 200 GΩ 200 GΩ

Continuity 0.01 to 200 Ω ■ ■ ■

Polarization Index PI ■ ■

Dielectric absobption rate DAR ■ ■

Frequency measurement ■ ■

Capacitance measurement ■ ■

Data storage ■ ■

Bluetooth downloading ■

Safety Cat IV Cat IV Cat IV

600 V 600 V 600 V

FREE calibration certificate ■ ■

MIT

400

MIT

410

MIT

420

MIT

430

MIT

480

MIT

481

MIT

485 SOIL RESISTIVITY TESTING

Megger DET4TD digital display four pole earth testing kit

■ Convenient to use■ Automatically carries out pre-test checks■ Weather and dust proof to IP54■ Comes complete with stakes and wires

Stakeless earth electrode testing

■ Large jaw opening■ Automatic self calibration■ Auto ranging■ High and low alarms

AV

0300

DC

M2033

DC

M2039

DC

M2R

DC

M104R

DC

M204R

DC

M300E

MM

C850

DET3

TA

DET3

TC

DET3

TD

DET4

TD

DET1

0C

DET2

0C

AV

O310

M7027

M7029

M8035

M8037