Electrical Charging System Solutions ZEFTRONICS vvvVVV ...electrical charging system solutions cross...
Transcript of Electrical Charging System Solutions ZEFTRONICS vvvVVV ...electrical charging system solutions cross...
ZEFTRONICS Electrical Charging System Solutions
CROSS REFERENCE VOLTAGE REGULATORS, ALTERNATOR & GENERATOR CONTROLLERS, STARTER GENERATOR CONTROLLERS. CURRENT &V CONTROLLER SENSORS. PARALLELING OVER
CURRENT/VOLTAGE PROTECTION UNITS. LIGHT, MOTOR & TEMPERATURE CONTROLLERS, TESTERS, & TIMERS
1622 E. Whaley St, Longview, TX 75601. USA
P: 888-309-3883 vvvVVV.zeftronics.com
F: 903-236-9766 [email protected]
14V Twin Engine Generator Controllers Units (GCU) Cross Reference
Photo System Volt Amp Generator Engine Benefits / Features Approval Replacement For Aircraft Eligibility
Zeftronics P/N
GEN 12V 35A Delco Twin • Voltage Regulation: 14.2V FAA-PMA Delco-Remy: Piper: PA-30 G135EN Remy Generator
• Current Limit: 35A • Trouble-shooting Light
1119145, 1119145E, Electrodelta:
• Reverse Current Protection VR300-14P-35 • Require separate Parallel (EQ) Relay PFT/Lamar: • Prevents Regulator cycling at low RPM DGR7-14P-35 • Eliminates Regulator Noise • Generator Controller Unit
GEN 12V 50A Delco Remy
Twin • Voltage Regulation: 14.2V • Current Limit: 50A
FAA-PMA Delco-Remy: 1119246,E Electrodelta:
Piper: PA-30, PA-23-150, PA-
G150EN
Generator • Trouble-shooting Light VR300-14P-50 23-160, PA-23- + Reverse Current Protection Piper: 450-385 235, PA-23- + Require separate Parallel (EQ) Relay PFT/Lamar: 250. • Prevents Regulator cycling at low RPM DGR7-14P-50 • Eliminates Regulator Noise Lycoming: 72077 • Generator Controller Unit
GEN 12V 35A Delco Twin • Voltage Regulation: 14.2V FAA-STC Zeftronics: G135EN Piper: PA-30 G135KN Remy • Current Limit: 35A FAA-PMA (GCU), Plus EQ1500 Generator • Trouble-shooting Light (EQR).
' 11116 • • a • Reverse Current Protection
• Has built-in Parallel (EQ) Relay Delco-Remy: 1119145, 1119145E;
• Prevents Regulator cycling at low RPM Electrodelta: • Eliminates Regulator Noise VR300-14P-35; • Generator Controller Unit PFT/Lamar:
DGR7-14P-35; plus the EQR
GEN 12V 50A Delco Remy
Twin • Voltage Regulation: 14.2V • Current Limit: 50A
FAA-STC FAA-PMA
Zeftronics: G150EN (GCU), Plus EQ1500
Piper: PA-30, PA-23-150, PA-
G150KN
Generator • Trouble-shooting Light (EQR). 23-160, PA-23- + Reverse Current Protection Delco-Remy: 1119246,E; 235, PA-23- •• Has built-in Parallel (EQ) Relay Electrodelta: VR300-14P- 250. • Prevents Regulator cycling at low RPM 50; Piper: 450-385; • Eliminates Regulator Noise PFT/Lamar: • Generator Controller Unit DGR7-14P-50;
Lycoming: 72077; plus EQR
Parts Cross Reference — Features, Specifications, Part Numbers, Eligibilities and Approvals may change with or without notice. Photos are for reference only, actual product may differ Date Issued 7/14/2014