Electric heaters, heat exchangers - Riviera Magi … horizontal or vertical collectors CIRCuLATIon...
-
Upload
nguyenkhue -
Category
Documents
-
view
217 -
download
1
Transcript of Electric heaters, heat exchangers - Riviera Magi … horizontal or vertical collectors CIRCuLATIon...
Application :
Heating of outdoor pools, indoor pools or spas.
Operating principle :
PSA electric heaters consist of a polyamide tube and an electric resistance. The water is heated in contact with the resistance as it passes through the tube.
Advantages :
• Low investment • Used with a TIME-OF-DAY tariff, it can cut consumption costs by up to 60% compared with a standard rate
tariff. Consult your electricity supplier. • In harsh climatic zones, it can also be used as a backup heater for an indoor pool heated by an EDENPAC
All Seasons heat pump. • Reliable : PSA’s unique polyamide-titanium technology ensures complete corrosion resistance. • Easy to use: set your heater to 28°C and enjoy…
Electric heaters
�
Installation • By a pool professional • In a technical room, after the filter unit.
RE/L - EQUIPPED • Red Line +L-shaped electric heater / straight electric heater
81
276
A
���
* manufacturing tolerance +/- 5% ** effective voltage tolerance + 6 - 10% EDF supply network*** For a max. length of 25 metres
Model 3 kW 6 kW 9 kW 12 kWItem code (Red line+) W40RDE3 W40RDE6 W40RDE9 W40RDE1�Item code (Red Line in case) W40RDC3Ti W40RDC6Ti W40RDC9Ti W40RDC1�TiItem code (RE/L equipped) W40LE03 W40LE06 W40LE09 W40LE1�Immersion heater power (kW)* 3 kW 6 kW 9 kW 1� kWAbsorbed intensity, three-phase 400 V (Amp.)**5 9 13 18Absorbed intensity, single-phase �30 V (Amp.)** 14 �7 40 –Supply cable cross-section, single-phase�30 V (mm�)*** 3 x 4 3 x 6 3 x 10 –Min. flow 5 m3/hMax. flow 30 m3/h (Red Line+ and Red Line in case) -�0 m3/h (RE/L equipped)Hydraulic piping 1/� unions + 50 Ø reducer (Red Line+ and Red Line in case)Hydraulic piping 50 or 63 Ø PVC (RE/L equipped)Weight (Red Line+ and Red Line in case) 4 kg (Red line+), 10 kg (Red line in case)Weight (kg) (RE/L equipped) 4 4 5 5A (mm) 45� 45� 55� 55�B (mm) 550 550 730 730C (mm) 395 395 575 575
B
3
C
PuMP
To PooL
FILTER
RE/L
WATER TREATMEnT
PuMPFILTER WATER TREATMEnTRED LInE +
ASPIRATIonTo PooL
ASPIRATIon
RE/UU-shaped electric heater
Equipment • Titanium resistances • Polyamide housing • Patented U-shaped 2 resistance design. You can
adapt your heater power to your pool’s needs by using one or both resistances.
• Digital controller • Flow switch • Safety thermostat • EC conformity
Installation • In a technical room, after the filter unit. • By a pool professional
Model RE/U 9 RE/U 12 RE/U 15 RE/U 18 RE/U 21 RE/U 24
Item code (RE/u single-phase) W40TIT9M W40TIT1�M W40TIT15M W40TIT18M - -
Item code (RE/u three-phase) W40TIT9 W40TIT1� W40TIT15 W40TIT18 W40TIT�1 W40TIT�4
Immersion heater power (kW)* 3 + 6 6 + 6 6 + 9 9 + 9 9 + 1� 1� + 1�
Absorbed intensity, three-phase 400V (A)** 13 18 �� �6 31 35
Supply cable cross-section, three-phase 400V (mm�)*** 5 x 4 5 x 4 5 x 6 5 x 6 5 x 10 5 x 10
Absorbed intensity, single-phase �30V (A)** 40 53 66 79 - -
Supply cable cross-section, single-phase �30V (mm�)*** 3 x 10 3 x 16 3 x 16 3 x 16 - -
Min. flow 5 m3/h 5 m3/h
Max. flow �� m3/h �� m3/h
Hydraulic piping 50 or 63 Ø PVC PVC Ø 50 ou Ø 63
Weight (kg) 1�
* manufacturing tolerance +/- 5%** effective voltage tolerance + 6 - 10% EDF supply network*** For a max. length of 25 metres
4
PuMP
To PooLASPIRATIon
FILTER RE/u WATER TREATMEnT
Application :
Heating of outdoor or indoor pools with a primary circuit from a boiler, solar heater or geothermal system.
Operating principle :
There are two counterflow water circuits in the heat exchanger : • The primary circuit : water coming from a solar or geothermal system or a boiler and supplying heat to the
pool • The secondary circuit: water coming from the pool to be heated
Advantages :
• Rapid rise in temperature when fed by a boiler: the pool can be heated to 28°C in 24 - 48 hours. Ideal if you want to make occasional use of your pool (weekend).
• Appropriate solution in terms of investment and consumption if you have natural gas (town gas). • Reliable : PSA’s unique polyamide-titanium technology ensures complete corrosion resistance • Easy to use: set your heat exchanger to 28°C and enjoy... When the temperature starts to rise, set the filter unit
to constant. When the required temperature is reached, change to automatic.
Heat exchangers
5
���
Heat Line + multitubular heat exchanger
Equipment • Titanium tubes • Polyamide housing • Digital controller • Flow switch • Circulation pump • Check valve • EC conformity
Installation • In a technical room, near the boiler and the filtration
unit. • By a pool professional
Model Heat Line 20+ Heat Line 40+ Heat Line 70+
Item code (equipped model, titanium) W49KT�0 W49KT40 W49KT70
Power with primary at 90°C (kW) �0 40 70
Power with primary at 60°C (kW) 8,5 17 30
Power with primary at 45°C (kW) 4 8 14
Piping
PRIMARY heating Ø �6/34 F Ø �6/34 F Ø �6/34 F
SEConDARY pool PVC Ø 63 or 50
Flows (m3/h)
PRIMARY heating 0,9 1,7 3
SEConDARY pool 10 15 �0
Pressure drops (mCE)
PRIMARY heating 0,15 0,� 0,3
SEConDARY pool 0,5 0,8 1
Service pressure � b � b � b
Weight (kg) 8 8 9
6
PuMP
To PooLASPIRATIon
FILTER HEAT LInE + WATERTREATMEnT
versradiateurs
PuMPFILTER HEAT LInE +
WATERTREATMEnT
To PooLASPIRATIon
To radiators
SEnSoR
CoLD WATER
SAnITARY HoT WATER
TRAnSFER unIT
500 - 1000 LITRE SoLAR
TAnK
198 Heat line 20 and 40328 Heat line 70
535 Heat line 20 and 40
only for 70 kW
665 Heat line 70
Installation • In a technical room, near the boiler and the filter
unit. • By a pool professional
UranusPlate heat exchanger
UP 35-70 UP 120-240 A 760 900
B 285 342
C 365 499
Model UP 35 UP 70 UP 120 UP 240
Item code W49 uP35Ti W49 uP70Ti W49 uP1�0Ti W49 uP�40Ti(pre-assembled model, titanium)
Power with primary at 90°C (kW) 35 70 1�0 �40
Power with primary at 60°C (kW) �0 40 65 130
Power with primary at 45°C (kW) 13 �5 31 57
Primary flow m3/h 1,5 3,1 3,53 7,06
Primary pressure drop mCE 1,6 1,7 �,19 �,7
Primary piping �6/34 �6/34 33/4� 33/4�
Secondary flow m3/h 1,5 3 4,16 8,3�
Secondary pressure drop mCE 1,7 1,8 3,�9 3,96
Secondary piping PVC Ø 50
Single-phase power supply �30 V / 50Hz
Weight (kg) 37 38 65 70
7
PuMP FILTERuRAnuSWATER
TREATMEnT
To PooL ASPIRATIon
To radiators
BY-PASS
To PooL ASPIRATIon
PuMP FILTERuRAnuSWATER
TREATMEnT
BY-PASS
BuFFER TAnK GEoTHERMAL
To other circuits
Return from other circuits
To horizontal or vertical collectors
CIRCuLATIon PuMP
Desig
n L.
Fléch
eux
- Pho
tos
: P. J
oly,
P. G
uira
ud -
Prin
ting
PGR
- 09/
�007
Free study !To select your equipment
Your
con
tact
det
ails
will
be
used
in a
ccor
danc
e w
ith th
e Fr
ench
Dat
a Pr
otec
tion
Act
of 6
Janu
ary
1978
. The
y w
ill n
ot b
e pa
ssed
on
to th
ird p
artie
s.
Zodiac, mastering the elements.
Pool features
Water heating
air heating and dehumidification
Customer references :.................................................................................................................................................................................................
Company..................................................................Name.................................................................... Position.........................................................
Address.......................................................................................................................................................................................................................
Town....................................................................................................................Postcode.................... Country.........................................................
Phone.......................................................................Fax........................................................................ E-mail...........................................................
Length.:................................................ m. Width.:......................................m. Depth.:.............................m
Area.:................................................... m2. Volume.:...................................m3
Situation...............................................m.outdoor.. m.indoor
Type.of.pool.........................................m.above.ground.. m.in.ground
Use.......................................................m.private.. m.public.-.please.specify.:. municipal.
. . m.fitness.centre.. m.camp.site.
. . m.physiotherapy.. m.Hotel
. . m.Other.:...............................................................................
Required.temperature.:......................... C°. Filtering.time.:.........................................................hours/day
Annual.period.of.use.:.from............................................................ to.....................................................................
Pool.with.roller-type.or.other.cover.. m.yes. . m.no
Pool.with.overflow.. m.yes.(.q.waterfall..q.chute). m.no
Pool.with.counter-current.swimming.. m.yes. . m.no
Wind.exposure. m.low... m.average.. m.high
Altitude.:.............................................. m
Other.(waterfall,.slide,.jacuzzi,…).:.........................................................................................................................
Required.room.temperature.:...................... C°. Volume.of.room.:...............................m3
Thermal.insulation.of.room.:. m.traditional.construction,.little.glazing,.well.insulated.
. m.traditional.construction,.large.amount.of.double-glazing,.well.insulated.
. m.fixed.shelter.
. m.telescopic.shelter.
. m.double-glazed.veranda.
. m.other.:...........................................................................
Mezzanine.:. m.yes. m.no
Type.of.surfaces.:. walls..................................................................................
. ceiling...............................................................................
. glazed.areas......................................................................
Position.of.dehumidifier.:. m.in.technical.room,.built-in.. m.ambient.
. m.in.technical.room,.ducted
Energy.used. m.electricity.-.please.specify.:.q.three-.or..q.single-phase.
. m.heat.pumps. m.natural.gas. m.propane.gas
. m.geothermal. m.oil.
Date :
Town :
.We.invite.you.to.complete.this.questionnaire..On.the.basis.of.the.information.you.provide,.we.will.conduct.a.(free).thermal.study.that.will.give.you.valuable.information.on.:. •.the.power.required.to.heat.your.pool,. •.the.selected.equipment,. •.the.consumption.costs,. •.the.temperature.rise.times.For.all.information,.visit.our.website.at.www.psa-zodiac.com.and.contact.your.“pool.consultant”.
Climatic area
Temperature data:
Winter : min.: °C
max.: °C
Spring : min.: °C
max.: °C
Summer : min.: °C
max.: °C
Autumn : min.: °C
max.: °C
Contact details of your pool specialist
Please return the questionnaire to the above address