ELASTIC SCATTERING IN D0 EXPERIMENT

18
______________________________ ____ C. Avila, small x workshop, ELASTIC SCATTERING IN D0 EXPERIMENT Carlos Avila Universidad de Los Andes Bogota, Colombia

description

ELASTIC SCATTERING IN D0 EXPERIMENT. Carlos Avila Universidad de Los Andes Bogota, Colombia. FPD has opened the opportunity to study elastic scattering in the D0 experiment. We show in this talk: The analysis of elastic triggers taken during FPD commissioning. - PowerPoint PPT Presentation

Transcript of ELASTIC SCATTERING IN D0 EXPERIMENT

Page 1: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

ELASTIC SCATTERING IN D0 EXPERIMENT

Carlos AvilaUniversidad de Los Andes

Bogota, Colombia

Page 2: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

FPD has opened the opportunity to study elastic scattering in the D0 experiment.

We show in this talk:

• The analysis of elastic triggers taken during FPD commissioning.

• Prospects for increasing the t range that can be covered by FPD.

Page 3: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

ELASTIC TRIGGER:

31 runs taken with detectors located at 9 from beam. ( = beam width): P1D=17.05mm, P2D=13.80mm A1U=12.57mm, A2U=9.11mm

Total of 1.3 million triggered events

DAQ used for FPD commissioning: Nim logic and camac readout.LM COUNTERS 2.5< <4.4

VC COUNTERS 5.2< <5.9

Page 4: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

DAQ USED FOR FPD COMMISIONING

Temporary DAQ used while FPD was integrating to D0 DAQ.

Capability for reading out one Spectrometer.

Page 5: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

HIT COORDINATE RECONSTRUCTION:

We can reconstruct coordinates using the UV, UX, VX intersections of fiber segments.

Comparison of coordinates obtained by different intersections is useful to determine the spatial resolution of the detector.

Page 6: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

1. Events were rejected if there was a fiber plane with multiple hits.

2. We required 3 reconstructed fiber segments per detector.

3. Required that reconstructed coordinates from UX and UV planes agreed within 2 standard deviations (Fiducial cut).

4. Rejected events that were out of our MC expected elastic acceptance region (Acceptance cut).

CUT # EVENTS AFTER CUT No cut 1,308,734

Fiber multip. cut 29,285

Segments cut 26,428

Fiducial cut 21,287

Acceptance cut 17,724

SELECTION OF ELASTIC EVENT CANDIDATES:

Page 7: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

FIBER MULTIPLICITY CUTS

Majority of events recorded have multiple hits in our detectors.

Particle showers seem to be produced in the separators located between P1 and P2.

Page 8: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

EVENTS THAT SURVIVED ALL CUTS

D0 Preliminary D0 Preliminary

D0 Preliminary

Page 9: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

SPATIAL RESOLUTIONDetermined from the difference between coordinates obtained from UV segment and coordinates obtained from UX segment.

D0 Preliminary

Page 10: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

ACCEPTANCE CORRECTIONS

covered by the PD spectrometer.

We also determine the error in acceptance due to error in detector position.

D0 Preliminary

Page 11: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

t distribution (uncorrected)

D0 Preliminary

Page 12: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

|t| slices in each detector

P1D P1D P2DP2D

Page 13: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

|t| range covered with the data shown here

Page 14: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

Can the FPD do studies of elastic events in the forward region?

FPD could give some light about the discrepancy between E710/E811 and CDF measurements of total cross section:

Page 15: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

MC for elastic events can tell the FPD running conditions to reach lower |t| values:

In the forward region we simulate:

dtd

dtd

dtd

dtd ncnc

)exp(16

)1(

)2

exp()()(

)(4

22

2

2

42

tBdtd

tBt

tGtdtd

ttG

dtd

Tn

Tcn

c

Add Tevatron lattice and include beam emittance in the simulation.

Page 16: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

A possible measurement of the Total cross section?

inelelt

nT NNdt

dN

1116

02

With beam injection lattice:

Page 17: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

Uncertainty on the measurement of _TOT due to extrapolation to t=0 (50000 elastic events):

Position |t|_range Slope _T(mb)

8 0.05<|t|<0.5 16.91±0.08 0.67

9 0.12<|t|<0.5 16.74±0.12 1.42

10 0.16<|t|<0.5 16.98±0.17 2.29

11 0.20<|t|<0.5 17.10±0.17 2.46

This error is only due to error in extrapolation. Still need to include error in the measurement of N inelastic

Page 18: ELASTIC SCATTERING IN D0 EXPERIMENT

__________________________________C. Avila, small x workshop, Sep. 17 2003

CONCLUSIONS

• Proton Antiproton elastic events have been very useful to test the performance of FPD detector.

• Analysis of elastic events recorded with the FPD in the range 0.9<|t|<1.7, during commissioning, is in a mature stage. It has proven difficult because we have fiber information from only one spectrometer.

• After Dec. 2003 elastic triggers will have fiber information from full FPD system. FPD will be able to reach up to a |t| value of 4.5.

• FPD detector rates have a large contribution from particle showers most likely produced in the electrostatic separators. Working with beam divisions on this issue.

• FPD has a chance to make a new measurement of the Total cross section but requires special low luminosity store running with beam injection lattice. Only need a few hours of running to collect enough statistics.