Elara Class B Tabletop Autoclaves · 5 pre-set programs, 2 test programs Bowie & Dick and Leak...
Transcript of Elara Class B Tabletop Autoclaves · 5 pre-set programs, 2 test programs Bowie & Dick and Leak...
Elara Class B Tabletop AutoclavesFor Medical & Dental Clinics
2
Class B PerformanceClass B performance is achieved with a built-in vacuum pump used for fractionated pre vacuum air removal eliminating air pockets from all load types and maximizing efficient steam penetration throughout the entire load. After the sterilization stage the vacuum pump is used for post-vacuum drying.
The Elara tabletop autoclave is a reliable and robust Class B Autoclave designed for the needs of modern clinics where autoclaves are expected to meet sophisticated international standards and operate non-stop every day. Elara Autoclaves are designed for the sterilization processing needs of Medical Clinics, Dental Clinics and Veterinary Clinics.
As a family owned business Tuttnauer has manufactured products for over 89 years that have developed a reputation for their quality, high performance, sophisticated features, and ability to satisfy customer expectations. Tuttnauer’s sterilization and infection control products are trusted at over 350 000 autoclave installations throughout the world.
LONG LASTING AUTOCLAVE | CONVENIENT | 30% ENERGY SAVER | EXTRA CAPACITY | SAFETY
Elara Class B Tabletop AutoclavesExceptional Performance & Exceptional Results
3
Top Quality Stainless Steel• Durable 316L stainless steel electro-polished chamber lasts
longer than competing 304 stainless steel chambers• Stainless steel door with mirror polish surface is highly resistant
to corrosion
Built-in system for checking water quality• Automatic water quality checking will alert the user of poor
water quality, protecting the autoclave chamber from corrosive minerals found in poor water.
• Sleep Mode - allows user to set time to switch sterilizer to minimum energy consumption
• Low Rate Cycle - you can run your sterilizer when electrical power costs are low, like after work hours, by setting a delayed start time.
30% More Tray Area
• You get extra tray space compared to other autoclaves that offer 17 to 20 liter chambers
• Extra capacity per cycle requires less cycles per day, saving you energy costs and water
Safety Features
• Two different locking mechanisms prevent the door from opening while the chamber is pressurized
• Cycle will not start if the door is not locked
• Door will not open at end of cycle until chamber pressure equalizes to room pressure
ENERGY SAVER
SAFETY
LONG LASTING AUTOCLAVE
30% EXTRA CAPACITY
Door
• Self-locking door designed to easily close/open door with one hand
CONVENIENTWater Filling
• Front water filling allows you to use the space above the autoclave
• Top water filling is also available
• Automatic feed water (optional) will automatically fill the autoclave reservoir with water
Standard Tray Capacity
Tuttnauer Tray Capacity
Elara Class B Tabletop Autoclaves
4
Real-Time Measured Values
Shows real-timevalues for chambertemperature &pressure, and generatorpressure
Cycle Parameters
Parameter settingsfor temperature,sterilization time anddrying time
Easy Pad
A user-friendly 3 button keypad enables the user to easily browse through the sterilization cycle program settings and user directories
Thermal PrinterOptional high quality built-in thermal printer for paper printouts
Control Panel
Innovative Multi-Color Display
A bright LCD panel for easy reading, with multilingual interface (26 languages).
5
Standards and DirectivesPartial list of standards and directives:
Pressure VesselAll pressure vessels and boilers are certified according to ASME code section I and section VIII, Div. I and PED 97/23/EC - Pressure Equipment Directive Quality Standards• ISO 9001:2008 - Quality Management Systems
• EN ISO 13485:2012 Quality Management System – Medical Devices
Directives• MDD 93/42/EEC amended in Directive 2007/47/EEC
• 2002/96/EC WEEE and 2002/95/EC RoHS
Standards
• AAMI/ANSI ST-55:2010, FDA 510K cleared (Elara 11)
• EN 13060: 2004+A2: 2010 - Small Steam Sterilizer
• EN 61010-1: 2010 Safety Requirements for measurement control and laboratory use
• EN 61326-1: 2006 Electrical Equipment for EMC Requirements
• EN 61010-2-40: 2005 Safety requirements for sterilizers used to treat medical materials
• EN 17665-1: 2006 Sterilization of health care products – moist heat
Remote PC Reporting (optional PC software)
Automatic Recording of Cycle Information to Your PC
Reporting You Can Rely On
• Automatic recording of cycle information to any PC on your network (Ethernet connection at back of autoclave)
• Convenient access to graphs and tables that are easy to understand
• Easily generate PDF reports• No need to file printouts, saving you time
R.PC.R Software
Digital Cycle Data on Your PCSave cycle data files on your PC with no additional software or specialized hardware
Connect USB memory
Create reports with R.PC.R
Select “Export History”
View cycle data files
on your PC
Connect USB memory to your PC
Optional
Elara Class B Tabletop Autoclaves
6
19.8 Liter
ModelChamber Volume
LitersNo. of
Trays Usable Tray Area (D x W) (in mm)
Standard Pouch Capacity
Voltage (V) Freq. (Hz)
Power(W) Current (A)
Elara 9D
19.8 L 4 Trays 415 x 170 16 Pouches 230V
50/60Hz
2200W/10A
Elara 9i 1800W/ 9A
Elara11D
28.5 L 6 Trays 415 x 170 24 Pouches 230V
50/60Hz
2200W/10A
Elara 11i 1800W/9A
Elara 9 loaded with 4 stainless steel trays (handle included)
316L Stainless Steel Chamber
Elara 9i
Elara 9D
Technical Specification
Standard Class B • High quality steam is generated inside the chamber
High Speed Class B • Fast cycles with powerful built-in steam generator
230mm
430mm
7
CycleProgram
Load TypeTemp.
C°Sterilization Time (min)
Dry Time (min) Cycle Time (min)*
Elara 9D Elara 11D
Elara 9iElara 11i
Elara 9D Elara 9iElara 11D
Elara 11i
Unwrapped 134 Unwrapped instruments 134 4 1 2 17 21 21 27
Wrapped 134 Wrapped instruments 134 4 20 25/30 24 42 27 48
Unwrapped 121 Unwrapped delicate instruments 121 20 1 2 32 34 34 38
Wrapped 121 Wrapped delicate instruments 121 20 20 25/30 34 59 37 62
Prion 134 Prion 134 18 20 25/30 34 56 41 63
Elara 11 loaded with 6 stainless steel trays (handle included)
28.5 Liter 316L Stainless Steel Chamber
Elara 11i
280mm
430mm
Standard Class B
• High quality steam
is generated inside
the chamber
Sterilization Programs
5 pre-set programs, 2 test programs Bowie & Dick and Leak test, and 20 customizable programs.Bowie & Dick test, also suitable for Helix test device, includes 3.5 min sterilization time without drying.Leak test checks that the chamber under vacuum does not leak.
* Cycle times are based on 1.5 kg standard load and do not include drying. Cycle times based on warm chamber and may change according to load size.
Elara 11DHigh Speed Class B
• Fast cycles with powerful
built-in steam generator
Elara Class B Tabletop Autoclaves
Complimentary Products
Sealing MachineEnsures that sterilized instruments remain s ea l e d a f t e r sterilization and maintain perfect sterility during their shelf-life.
Water DistillerUse m ine ra l - f r ee wa te r t o p r o t e c t your autoclave and i n s t r umen t s a t a fraction of the cost of bottled distilled water.
Ultra Sonic CleanerUltrasonic cleaning is a safe and efficient procedure that ensures perfect cleaning.
International Sales and MarketingE-mail: [email protected]
Tuttnauer Europe b.v.Hoeksteen 11, 4815 PRP.O.B. 7191, 4800 GD BredaThe NetherlandsTel: +31 (0) 765 423 510 Fax: +31 (0) 765 423 540E-mail: [email protected]
Tuttnauer USA Co.25 Power Drive,Hauppauge, NY 11788Tel: +800 624 5836, +631 737 4850 Fax: +631 737 0720E-mail: [email protected]
Tabletop Line
Distributed by:
Learn fr om our ExpertsJoin our blog www.tuttnauer.com/blog
LTR330-0074/
ELA9
-11/IN
T/V-2/
10.15Elara Class B Tabletop Autoclaves
Elara 11i / 11D front view Elara 11i / 11D front view Elara 9i / 9D / 11i / 11D side view