Egyptian Accreditation Council f???K:« EGAC „U - 15-1... · Schedule of Accreditation...
Transcript of Egyptian Accreditation Council f???K:« EGAC „U - 15-1... · Schedule of Accreditation...
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 1 of 3
F09P15G 5 / Dec 2009
Brief Description of 0BMeasurement and Equipment Used
1BCalibration and Measurement Capability (±) 2BRange 3BMeasured Quantity
Electricity DC Voltage - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/301
9.1 µV 200 mV Calibration of DC Voltage Source
9.9 µV 2 V
41 µV 20V
0.6 mV 200 V
6.1 mV 1000 V
- Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/302
9.1 µV 220 mV Calibration of DC Voltage Measuring Equipment 11 µV 2.2 V
39 µV 11V
40 µV 22 V
0.5 mV 220 V
6.9 mV 1100 V
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 2 of 3
F09P15G 5 / Dec 2009
Brief Description of 4BMeasurement and Equipment Used
5BCalibration and Measurement Capability (±) 6BRange 7BMeasured Quantity
Electricity AC Voltage - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/303
200 mV Calibration of AC Voltage Source 61 µV 20 Hz
60 µV 55 Hz
60 µV 605 Hz
59 µV 1 kHz
61 µV 3 kHz
61 µV 10 kHz
72 µV 30 kHz
0.11mV 60 kHz
0.11 mV 100 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 3 of 3
F09P15G 5 / Dec 2009
8BBrief Description of 9BMeasurement and Equipment Used
10BCalibration and Measurement Capability (±) 11BRange 12BMeasured Quantity
Electricity AC Voltage
- Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/303
2 V Calibration of AC Voltage Source 0.14 mV 20 Hz
0.11 mV 55 Hz
0.10 mV 305 Hz
0.10 mV 1kHz
0.13 mV 3 kHz
0.26 mV 10 kHz
0.26 mV 30 kHz
0.77 mV 60 kHz
0.77 mV 100 kHz
0.30 mV 500 kHz
0.30 mV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 4 of 3
F09P15G 5 / Dec 2009
Brief Description of 13BMeasurement and Equipment Used
14BCalibration and Measurement Capability (±) 15BRange 16BMeasured Quantity
Electricity AC Voltage - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/303
20 V Calibration of AC Voltage Source 1.4 mV 20 Hz
1.1 mV 55 Hz
0.97 mV 305 Hz
0.97 mV 1 kHz
1.3 mV 3 kHz
2.6 mV 10 kHz
2.6 mV 30 kHz
7.7 mV 60 kHz
7.7 mV 100 kHz
0.30 V 500 kHz
0.30 V 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 5 of 3
F09P15G 5 / Dec 2009
Brief Description of
17BMeasurement and Equipment Used 18BCalibration and Measurement
Capability (±) 19BRange 20BMeasured Quantity
Electricity AC Voltage - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/303
200 V Calibration of AC Voltage Source 14 mV 20 Hz
12 mV 55 Hz
10 mV 305 Hz
9.9 mV 1 kHz
13 mV 3 kHz
26 mV 10 kHz
26 mV 30 kHz
77 mV 60 kHz
77 mV 100 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 6 of 3
F09P15G 5 / Dec 2009
Brief Description of 21BMeasurement and Equipment Used
22BCalibration and Measurement Capability (±) 23BRange 24BMeasured Quantity
Electricity AC Voltage - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/303
1000 V Calibration of AC Voltage Source 0.14 V 55 Hz
0.14 V 305 Hz
0.14 V 1 kHz
0.14 V 3 kHz
0.14 V 10 kHz
0.27 V 30 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 7 of 3
F09P15G 5 / Dec 2009
Brief Description of
25BMeasurement and Equipment Used 26BCalibration and Measurement
Capability (±) 27BRange 28BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
2.2 mV Calibration of AC Voltage Measuring Equipment 4.6 µV 10 Hz
4.3 µV 40 Hz
4.3 µV 500 Hz
4.3 µV 1 kHz
4.3 µV 10 kHz
4.3 µV 20 kHz
4.5 µV 50 kHz
6.1 µV 100 kHz
12 µV 300 kHz
23 µV 500 kHz
26 µV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 8 of 3
F09P15G 5 / Dec 2009
Brief Description of 29BMeasurement and Equipment Used
30BCalibration and Measurement Capability (±) 31BRange 32BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
22 mV Calibration of AC Voltage Measuring Equipment 9.1 μV 10 Hz
6.1 μV 40 Hz
5.9 μV 500 Hz
5.9 μV 1 kHz
5.9 μV 10 kHz
5.9 μV 20 kHz
8.2 μV 50 kHz
15 μV 100 kHz
31 μV 300 kHz
48 μV 500 kHz
74 μV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 9 of 3
F09P15G 5 / Dec 2009
Brief Description of 33BMeasurement and Equipment Used
34BCalibration and Measurement Capability (±) 35BRange 36BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
220 mV Calibration of AC Voltage Measuring Equipment 39 μV 10 Hz
17 μV 40 Hz
16 μV 500 Hz
16 μV 1 kHz
16 μV 10 kHz
16 μV 20 kHz
28 μV 50 kHz
63 μV 100 kHz
0.11 mV 300 kHz
0.17 mV 500 kHz
0.32 mV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 10 of 3
F09P15G 5 / Dec 2009
Brief Description of 37BMeasurement and Equipment Used
38BCalibration and Measurement Capability (±) 39BRange 40BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
2.2 V Calibration of AC Voltage Measuring Equipment 0.29 mV 10 Hz
0.11 mV 40 Hz
54 μV 500 Hz
54 μV 1 kHz
54 μV 10 kHz
54 μV 20 kHz
87 μV 50 kHz
0.14 mV 100 kHz
0.51 mV 300 kHz
1.2 mV 500 kHz
2.0 mV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 11 of 3
F09P15G 5 / Dec 2009
Brief Description of 41BMeasurement and Equipment Used
42BCalibration and Measurement Capability (±) 43BRange 44BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
22 V Calibration of AC Voltage Measuring Equipment 2.9 mV 10 Hz
1.1 mV 40 Hz
0.53 mV 500 Hz
0.53 mV 1 kHz
0.53 mV 10 kHz
0.53 mV 20 kHz
0.87 mV 50 kHz
1.2 mV 100 kHz
3.4 mV 300 kHz
12 mV 500 kHz
18 mV 1 MHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 12 of 3
F09P15G 5 / Dec 2009
Brief Description of
45BMeasurement and Equipment Used 46BCalibration and Measurement
Capability (±) 47BRange 48BMeasured Quantity
Electricity AC Voltage
- Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/304
220 V
29 mV 10 Hz
11 mV 40 Hz
11 mV 500 Hz
11 mV 1 kHz
11 mV 10 kHz
11 mV 20 kHz
9.4 mV 50 kHz
18 mV 100 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 13 of 3
F09P15G 5 / Dec 2009
Brief Description of 49BMeasurement and Equipment Used
50BCalibration and Measurement Capability (±) 51BRange 52BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A & 5725A
S.N.: 9375206 & 9402001
Direct Comparison Method ECL/CM/304
600 V Calibration of AC Voltage Measuring Equipment 0.37 V 40 Hz
0.37 V 55 Hz
0.37 V 500 Hz
0.37 V 1 kHz
0.37 V 10 kHz
0.37 V 20 kHz
0.37 V 30 kHz
0.37 V 50 kHz
1.4 V 100 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 14 of 3
F09P15G 5 / Dec 2009
Brief Description of 53BMeasurement and Equipment Used
54BCalibration and Measurement Capability (±) 55BRange 56BMeasured Quantity
Electricity AC Voltage - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A & 5725A
S.N.: 9375206 & 9402001
Direct Comparison Method ECL/CM/304
1000 V Calibration of AC Voltage Measuring Equipment 0.11 V 40 Hz
0.11 V 55 Hz
0.11 V 500 Hz
0.11 V 1 kHz
0.18 V 3 kHz
0.18 V 10 kHz
0.18 V 20 kHz
0.61 V 30 kHz
1100 V
91 mV 55 Hz
91 mV 500 Hz
91 mV 1 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 15 of 3
F09P15G 5 / Dec 2009
Brief Description of 57BMeasurement and Equipment Used
58BCalibration and Measurement Capability (±) 59BRange 60BMeasured Quantity
Electricity DC Current - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/305
1.8 nA 200 µA Calibration of DC Current Source
18 nA 2 mA
0.19 μA 20 mA
5.6 μA 200 mA
0.20 mA 2 A
4.4 mA 20 A
DC Current - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/306
59 nA 220 µA Calibration of DC Current Measuring Equipment
42 nA 2.2 mA
0.4 μA 22 mA
5.2 μA 220 mA
99 μA 2.2 A
3.7 mA 11 A
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 16 of 3
F09P15G 5 / Dec 2009
Brief Description of 61BMeasurement and Equipment Used
62BCalibration and Measurement Capability (±) 63BRange 64BMeasured Quantity
Electricity AC Current - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/307
200 µA Calibration of AC Current Source
70 nA 55 Hz
70 nA 305 Hz
71 nA 1kHz
72 nA 5 kHz
81 nA 10 kHz
2 mA
0.51 μA 55 Hz
0.50 μA 305 Hz
0.50 μA 1kHz
0.51 μA 5 kHz
0.51 μA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 17 of 3
F09P15G 5 / Dec 2009
Brief Description of 65BMeasurement and Equipment Used
66BCalibration and Measurement Capability (±) 67BRange 68BMeasured Quantity
Electricity AC Current - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/307
20 mA Calibration of AC Current Source 5.0 μA 55 Hz
5.0 μA 305 Hz
5.0 μA 1kHz
6.2 μA 5 kHz
5.0 μA 10 kHz
200 mA
4.9 μA 55 Hz
4.9 μA 305 Hz
4.9 μA 1kHz
4.9 μA 5 kHz
4.9 μA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 18 of 3
F09P15G 5 / Dec 2009
Brief Description of 69BMeasurement and Equipment Used
70BCalibration and Measurement Capability (±) 71BRange 72BMeasured Quantity
Electricity AC Current - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/307
2 A Calibration of AC Current Source 0.82 mA 55 Hz
0.82 mA 305 Hz
0.82 mA 1kHz
0.94 mA 5 kHz
0.97 mA 10 kHz
20 A
10 mA 55 Hz
10 mA 305 Hz
10 mA 1kHz
27 mA 5 kHz
27 mA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 19 of 3
F09P15G 5 / Dec 2009
Brief Description of
73BMeasurement and Equipment Used 74BCalibration and Measurement
Capability (±) 75BRange 76BMeasured Quantity
Electricity AC Current
- Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/308
220 µA Calibration of AC Current Measuring Equipment
25 nA 55 Hz
25 nA 400 Hz
25 nA 1 kHz
46 nA 5 kHz
0.19 μA 10 kHz
2.2 mA
0.19 μA 55 Hz
0.19 μA 400 Hz
0.19 μA 1 kHz
0.35 μA 5 kHz
1.8 μA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 20 of 3
F09P15G 5 / Dec 2009
Brief Description of
77BMeasurement and Equipment Used 78BCalibration and Measurement
Capability (±) 79BRange 80BMeasured Quantity
Electricity AC Current - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/308
22 mA Calibration of AC Current Measuring Equipment
1.6 μA 55 Hz
1.6 μA 400 Hz
1.6 μA 1 kHz
4.4 μA 5 kHz
16 μA 10 kHz
220 mA
15 μA 55 Hz
15 μA 400 Hz
15 μA 1 kHz
24 μA 5 kHz
0.12 mA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 21 of 3
F09P15G 5 / Dec 2009
Brief Description of
81BMeasurement and Equipment Used 82BCalibration and Measurement
Capability (±) 83BRange 84BMeasured Quantity
Electricity AC Current
- Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/308
2.2 A Calibration of AC Current Measuring Equipment
0.30 mA 55 Hz
0.30 mA 400 Hz
0.30 mA 1 kHz
0.54 mA 5 kHz
7.2 mA 10 kHz
11 A
4.8 mA 55 Hz
4.8 mA 400 Hz
4.8 mA 1 kHz
9.9 mA 5 kHz
37 mA 10 kHz
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 22 of 3
F09P15G 5 / Dec 2009
rief Description of 85BMeasurement and Equipment Used
86BCalibration and Measurement Capability (±) 87BRange 88BMeasured Quantity
Electricity Resistance - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/309
95 μΩ
1 Ω Calibration of Resistance Measuring Equipment 0.19 mΩ 1.9 Ω
0.24 mΩ 10 Ω
0.48 mΩ 19 Ω
1.1 mΩ 100 Ω
61 mΩ 190 Ω
9.6 mΩ 1 kΩ
18 mΩ 1.9 kΩ
90 mΩ 10 kΩ
0.18 Ω 19 kΩ
1.2 Ω 100 kΩ
2.6 Ω 190 kΩ
21 Ω 1 MΩ
48 Ω 1.9 MΩ
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 23 of 3
F09P15G 5 / Dec 2009
Brief Description of
89BMeasurement and Equipment Used 90BCalibration and Measurement
Capability (±) 91BRange 92BMeasured Quantity
Electricity Resistance - Multifunction Calibrator Manufacturer: Fluke P.N.: 5720A S.N.: 9375206
Direct Comparison Method ECL/CM/309
0.40 kΩ 10 MΩ Calibration of Resistance Measuring Equipment 1.0 kΩ 19 MΩ
10 kΩ 100 MΩ - Reference Multimeter Manufacturer: Fluke P.N.: 8508A S.N.: 936954335
Direct Comparison Method ECL/CM/310
21 μΩ
2 Ω Calibration of Resistance Source
0.28 mΩ
20 Ω
2.5 mΩ 200 Ω
8.8 mΩ 2 kΩ
89 mΩ 20 kΩ
0.90 Ω 200 kΩ
12 Ω 2 MΩ
0.48 kΩ 20 MΩ
23 kΩ 200 MΩ
2.5 MΩ 2 GΩ
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 24 of 3
F09P15G 5 / Dec 2009
Brief Description of
93BMeasurement and Equipment Used 94BCalibration and Measurement
Capability*(±) 95BRange 96BMeasured Quantity
Frequency - Frequency Counter (Rubidium Time Base) Manufacturer: Fluke P.N.: PM6681R S.N.: SM939859
Direct Comparison Method ECL/CM/201
6.5 E-9 up to 8 GHz Calibration of Frequency
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 25 of 3
F09P15G 5 / Dec 2009
Brief Description of 97BMeasurement and Equipment Used
98BCalibration and Measurement Capability*(±) 99BRange 100BMeasured Quantity
Pressure 101B- Hydraulic Pressure Controller / Calibrator Manufacturer: DHI (FLUKE) Model: PPCH 70M A 70Ms/A20Mp P.N.: FAM0010 S.N.: 353
DKD-R 6-1:2003 1.8 psi 5 psi
0 to 1500 psi 1500 to 10000 psi
Calibration of Hydraulic Digital pressure gauge
106B- Pneumatic Pressure Controller/Calibrator Manufacturer: DHI (FLUKE) Model: PPC3 10MA 10Ms/A2Mp P.N.: FAM0007 S.N.: 1066
DKD-R 6-1:2003 0.3 psi 1.8 psi
0 to 100 Psi 100 to 1500 psi
Calibration of Pneumatic Digital pressure gauge
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 26 of 3
F09P15G 5 / Dec 2009
Brief Description of 111BMeasurement and Equipment Used
112BCalibration and Measurement Capability*(±) 113BRange 114BMeasured Quantity
Torque 115B- Torque Tester Indicator: S.N.: 03901 117B- Torque Transducers S.N.: 03901
ISO 6789:2003 13 ( Ft-Lb) 100 – 1000 (Ft- lb) Calibration of Torque wrenches
in CW & CCW Direction
Schedule of Accreditation Calibration Laboratory of EgyptAir Maintenance and Engineering Company
Cairo International Airport, Cairo, Egypt
Valid to : December 30, 2018 Revision No. 1: Febrery 2, 2014 Issue No. (3): January 15, 2015 Schedule No.: 206104 B R
(*) Calibration and Measurements Capabilities are to be expressed as expanded uncertainty (k=2)i.e. providing a level of confidence of approximately 95%.
Kornish El-Maadi, Riad El-Maadi Tower 1 - Cairo - Egypt مصـر –القـاهرة -١بـرج ريـاض املعـادى –كـورنيش املعـادى Tel.: (202) 5275220/5275224/5275225/5275227) ٢٠٢( ٥٢٧٥٢٢٠/ ٥٢٧٥٢٢٤ / ٥٢٧٥٢٢٥/ ٥٢٧٥٢٢٧ تليفـون : Fax: (202) 5275226)٢٠٢( ٥٢٧٥٢٢٦ فاكس :
f???K:« v???Mu« œU??Lû „U≈
Egyptian Accreditation Council EGAC
Page 27 of 3
F09P15G 5 / Dec 2009
Brief Description of 119BMeasurement and Equipment Used
120BCalibration and Measurement Capability*(±) 121BRange 122BMeasured Quantity
Dimension - Gauge Blocks Manufacturer: Mitutoyo, Japan S.N.: 731723, P.N.: 516-963 - Gauge Blocks Manufacturer: Harbot, England S.N.: N.A, P.N: D-973 - Black granite S.N.: 11408, 21047 - Calibration tester S.N.: 73510, S.N.: 72362, P.N.: 521-101, , P.N.: 521-102
BS 907:1965 ES 617:1991
1.2 µm 55 µ inch
mm 75 ـــ 0 inch 3 ـــ 0
Calibration of Dial Indicator
- Gauge Blocks Manufacturer: Mitutoyo, Japan S.N.: 731723, P.N.: 516-963 - Gauge Blocks Manufacturer: Matrix S.N.: 0902585, P.N.: 516-702-10 - Gauge Blocks Manufacturer: Harbot, England S.N.: N/A, P.N.: D-973
BS 6468:1984
4.8 µm 207 µ inch
mm 100 ـــ 0 inch 4 ـــ 0
Calibration of Depth Micrometer
BS 870:1950 ES 163:2008
2.8 µm 260 µ inch
mm 100 ـــ 0 inch 4 ـــ 0
Calibration of External Micrometer
BS 887:1982 BS 6365:1983 DIN 862:1989
7 µm 370 µ inch
mm 300 ـــ 0 inch 6 ـــ 0
Calibration of Calipers