Effects on lift products by EN 81-1/2 re-draftingEffects on lift products by EN 81-1/2 re-drafting

EN 81-20 / 50EN 81-20 / 50

Asansor Istanbul 2011 April 15th, 2011 IstanbulIan JONESConvenor CEN/ TC10/WG1

Page 2: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ContentsContents

The revision of EN 81 Parts 1 & 2 to become EN 81 Parts 20 and 50 will be the greatest change to the lift design standards in the last 20 years.

They contain many changes which will effect lifts manufacture.

This presentation gives a brief overview of some of the major anticipated changes to the lifts design.

2

Page 3: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ContentsContents

Text marked in blue is foreseen to effect the manufacturers.

Text marked in green is foreseen as effecting the selling company as information which may be needed to be provided to others.

3

Page 4: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Warning !Warning !

This presentation only shows what has been agreed so far by CEN/TC10/WG1.

Nothing has as yet been approved by the National Standards Bodies.

Therefore persons should not take the content of this presentation as a means to start to change their product or even to consider that all of the content will be approved.

This presentation only shows some of the major changes. There are many other alterations to the previous EN 81-1 an EN 81-2 requirements.

4

Page 5: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Assumptions,Assumptions,Scope, Definitions and EN Scope, Definitions and EN

414414

5

Page 6: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

AssumptionsAssumptions

Forces which a person might be expected to exert :• 300 N under normal conditions• 1000 N for impact (person falling against) unless specifically

specified elsewhere in the standard.

Requirement to discuss with the user the type of device used for loading and unloading the lift.

It is now assumed that all hydraulic fluid used complies with ISO 6743-4. (specification for hydraulic oils)

The machinery spaces containing hydraulic equipment are designed such that they will contain any spilt fluids.

6

Page 7: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

AssumptionsAssumptions

Requirements to ventilate the well and machinery spaces have been moved to the assumptions with then a large section of text in the new informative annex to give some guidance on this subject.

Therefore the responsibility to ventilate the well, with information provided by the lift installer, becomes the responsibility of the building designer/architect.

This is due to the wide coverage of the subject in National Building regulations which would otherwise conflict with the requirements of the new standards.

7

Page 8: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Scope + DefinitionsScope + Definitions

Only change from EN 81-1/2 + A3 is to exclude all hydraulic product where the setting of the relief valve is greater than 50 Mpa.

New definitions are given for :- Authorized persons Competent persons Maintenance Rescue Operations Special Tools

8

Page 9: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

EN414 RequirementsEN414 Requirements

A new table is given for significant hazards accounted for in the standard using the list found in EN 14121-1, in accordance with the new EN 414 layout of the standard.

Due to this standard, all the clauses previously numbered from 5 to 16 will now be covered in a new Clause 5.This will mean nearly all clauses are renumbered from those that exist today.

In addition some chapters will be split to make them easier to understand.

9

Page 10: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The WellThe Well

10

Page 11: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The wellThe well

Where there is more than 11 m between consecutive floors there is now an option to have :

• Intermediate emergency doors.• Adjacent lift cars with emergency doors• Electrical emergency operation.

Glass panels used in the construction of the well must be able to withstand 300 N applied over an area of 0,3 m x 0 3 m.

Where there are accessible spaces under the pit and a suitable pier is used as a means of protecting against a falling counterweight, the kinetic energy forces must be communicated to the builder.

11

Page 12: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The well The well (continued)(continued)

Protection in the well:

New requirements changing the dimensions of counterweight screens and a requirement to withstand 300 N without deflecting into the path of the counterweight.

The requirement for shaft division screens has now been changed from 500 mm from the side of the car to the nearest moving part, to 500 mm from the handrail to the nearest moving part.

12

Page 13: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The well The well (continued)(continued)

Headroom and Pit Safety Spaces

There must be standing areas for the number of persons anticipated to work on the car and in the pit and clear signage stating how many persons are permitted to work there.

Each person must have their own safety space available.

Clearance over fixed equipment increased to 500 mm with exception of the handrail

Handrails to have 400 mm horizontal clearance to items outside the projected area of the car.

New requirements for clearances around guide rails for the pit.

13

Page 14: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The well The well (continued)(continued)

New requirements for pit access ladders and to provide them with a safety contact where necessary.

Normative text in clause 5, combined with a new normative annex giving the possible ladder types.

“Movable” ladder fastened (1) in the pit and can be placed in climbing position (2).

CHAIN OR ROPE FOR PREVENTING REMOVAL FROM THE PIT

1,

10 m

Fixation of ladder feet for preventing tripping over

2

2

1

14ExamplesExamplesExamplesExamples

Page 15: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

The well The well (continued)(continued)

New requirement for a pit inspection control station.

This shall be interlocked with the one on the car roof to prevent confusion between which device takes priority.

• In the event of persons on the car roof and in the pit the car shall only move when the same button is pressed on both units.i.e. to move the car up the “UP” button must be pressed simultaneously on both control stations.

15

Page 16: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

MachineryMachinerySpacesSpaces

16

Page 17: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Machinery SpacesMachinery Spaces

New rules with regard to differences in floor levels and gaps in floors resulting in the possible need for additional ladders and barriers.

Modified rules for lighting levels in machinery spaces :

• 200 lux where work is carried out and for movement between work areas.

New rules for guarding of pulleys in the well and the ability to access them in safety for maintenance.

17

Page 18: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Machinery SpacesMachinery Spaces

Where work is required to be carried out from the car roof and the position is assured by fixed mechanical devices, where these cannot be disengaged under loss of power due to the forces applied to the car a means of escape must be assured.

• Exit via a space between car roof and underside of landing door

• Exit via the car through a trapdoor• Exit via an emergency door in the well.

18

Page 19: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing & Car EntrancesLanding & Car Entrances

19

Page 20: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing / Car DoorsLanding / Car Doors

The clauses for landing and car doors have been combined All fire test certification of lift landing doors shall be to EN

81-58. All doors in future, including their frame, will be subject to

soft and hard pendulum impact testing at their weakest points.

• The details of the tests will be found in EN 81-50.

20

Page 21: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing / Car DoorsLanding / Car Doors

New requirements for strength / forces :

1000 N force applied over an area of 100 cm2 shall cause no permanent damage.

Retaining devices are to be provided should the main guiding elements fail, and these also to be impact tested.

New requirement to remove lift from service or lower door force to 4 J should the detecting/reopening device fail. Also audible warning in this mode.

New requirement for 1000 N and 300 N forces applied to doors and locks to act simultaneously for design and test purposes.

21

Page 22: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing / Car Doors Landing / Car Doors (continued)(continued)

New design requirements :

New requirements for protection of children's fingers on glass doors.

• Making the glass opaque on the side exposed to the user by the use of either frosted glass or the application of frosted material to a height of minimum 1,10 m;

• Sensing the presence of fingers at least up to 1,6 m above sill and stopping the door movement in opening direction;

• Limiting the gap between door panels and frame to maximum 4 mm at least up to 1,6 m above sill. Recesses (framed glass, etc.) shall not exceed 1 mm. The maximum radius on the outer edge of the frame adjacent to the door panel shall not be more than 4 mm.

22

Page 23: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing / Car Doors Landing / Car Doors (continued)(continued)

New design requirements :

Car door not to be able to be opened more than 100 mm under manual effort when outside of unlocking zone.

New requirements for fire/smoke labyrinth design on closing edges of doors and frames.

Door leading edge not to be less than 20 mm thick if made from glass.

23

Page 24: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Landing / Car Doors Landing / Car Doors (continued)(continued)

New design requirements :

If lowest landing door lock is not within 1m of pit access ladder a means to be provided to unlock the doors from the pit.

New rules for the maximum height of the unlocking mechanism from the landing floor, depending if in the vertical or horizontal plane.

24

Page 25: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Lift CarLift Car

25

Page 26: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Lift CarLift Car

Car Loading: Load will continue to be calculated at 75 kg per person.

Car area to be calculated as from wall to wall body inner dimensions. Finishes are excluded.

Areas which cannot accommodate a person due to their size need not be included in the floor area calculation.

Door entrance recesses of less than 100 mm depth need not be included in the floor area calculation.

A new sample calculation, including loading devices is given.

New requirement for combustibility of car materials to EN 13501-1.

26

Page 27: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Lift CarLift Car

New design requirements : Loads to test for permanent deflection to now be

applied from outside and inside the car.

New requirements for car to car rescue and the provision of a portable bridge.

Surface of car roof where persons work to be made from non-slip material.

Modified requirements for normal car lighting and emergency lighting lux levels.

27

Page 28: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Lift CarLift Car

New design requirements :

New requirement for the car apron

• Must withstand a horizontal force of 300 N without deflection greater that 25 mm.

New requirements for the balustrade.

• All lift cars regardless of well clearances to have a “toe board” around the car roof edge.

• New requirements for the use of 1100 mm high balustrades

• Must also withstand horizontal force of 300 N28

Page 29: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Lift CarLift Car

≤ 150≤ 150

> 300

300

No balustrade required but needs toe board 100mm

Balustrade Required Height ≥ 700 mm

500

700> 300

> 500

Balustrade Required

Height ≥ 1100 mm

1100

29

Page 30: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

SuspensionSuspension

30

Page 31: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Means of suspensionMeans of suspension

No new technologies such as belts or alternative forms of ropes have been incorporated at this time.

This is due to concerns over the inclusion of patented or copyright protected materials.

It is however likely that future revisions would include such materials.

31

Page 32: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Means of suspensionMeans of suspension

All ropes to be to EN 12385-5 (Harmonized under Lifts Directive)

No longer possible to use rope grips as a means of rope termination. Terminations shall be to EN 13411-3, 6 or 7.

Rope traction• Either ropes shall slip if car or counterweight is blocked, or• Drive system to limit motor torque.

The calculations given in annex M will be move to EN 81-50. These have been modified slightly from those in the present standard.

32

Page 33: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Overspeed, Overspeed, Safety Gear & Safety Gear & Unintended Unintended MovementMovement

33

Page 34: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Deceleration RatesDeceleration Rates

After much discussion the decision was taken not to make any proposals to change deceleration rates of safety gear and buffers in the new standards.

Instead CEN/TC10 will work with ISO/TC178 to elaborate global requirements for safety gear, buffers and emergency electrical stops, which may then be incorporated in all lift standards throughout the world.

34

Page 35: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

DeletionsDeletions

The following items are now deleted :

All references to instantaneous safety gear with buffered effect.

All references to energy accumulation buffers with buffered return movement

• Neither of these devices were found to be used by manufactures.

All references to Hydraulic clamping devices. References to “fly ball” speed governors.

35

Page 36: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Uncontrolled MovementUncontrolled Movement

Distances between wall and car sill, when car is below the floor, have been changed to a diagonal to ensure the gap is properly covered where doors are mounted on large sill angles, etc.

200

36

Page 37: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Guide RailsGuide Rails

37

Page 38: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Guide RailsGuide Rails

Some small modifications to the guide rail calculations.

Tensile strength used in the calculations should be given by the guide rail manufacturer.

Where the lift travel is greater than 40 m the guide rail buckling calculations shall include any forces imparted on the rails by the guide brackets due to settlement of the building structure. (Also required for all timber framed buildings)

38

Page 39: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Guide RailsGuide Rails

Annex G This annex giving example calculations will now

become part of EN 81-50.

It will continue to give examples based on the Omega method but will also state that other methods of calculation are permissible

Eurocode 3 Finite Element Analysis

In any case the requirements of EN 81-20 shall be met.

39

Page 40: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

BuffersBuffers

40

Page 41: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

BuffersBuffers

Where buffers travel with either the car or counterweight the position at which they strike the pit floor must be clearly marked with a pedestal not less than 300 mm high.

This is not required for the counterweight if the screen extends to within 100 mm of the pit floor.

For hydraulic lifts with telescopic jacks at least one stage shall not hit its down travel mechanical limit when the car is fully buffered.

41

Page 42: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

BuffersBuffers

All buffers, except energy accumulation type, shall have a label with the type certificate number, buffer type, and oil details where hydraulic.

For Accumulation type buffers with non-linear characteristics the maximum compression now takes consideration of the fixing element.

Accumulation type buffers made from synthetic materials have to be checked periodically on aging considering instructions from the manufacturer.

42

Page 43: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Electrical Electrical Installation & Installation &

AppliancesAppliances

43

Page 44: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Electrical InstallationElectrical Installation

The AH6 groups task was one of the longest to complete since the electrical sections of EN 81-1 and EN 81-2 have not changed in any substantive way since 1989.

All electrical equipment shall now be in All electrical equipment shall now be in accordance with EN 60204-1 unless accordance with EN 60204-1 unless otherwise described.otherwise described.

44

Page 45: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Electrical InstallationElectrical Installation

Dimension now given for position of equipment to allow maintenance access.

Labelling now required for electrical and thermal hazards.

Protection against electrical shock shall comply with IEC 60364-4-41 and EN 50274.

Socket outlets to be provided with RCD at 30 mA

45

Page 46: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Electrical InstallationElectrical Installation

SIL levels of electric safety devices have been set to be the same in comparative ISO standards.

When the design of a safety device (listed in Annex A) includes software, it shall be possible to identify the failure state of the device, either by built-in system or by an external tool, if this external tool is a special tool, it shall be available on the site.

46

Page 47: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ControlsControls

47

Page 48: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ControlsControls

All docking operations are deleted as no longer being of relevance to the market.

Inspection controls are to stop the lift with 2 m clearance in the pit and headroom. Further movement towards the minimum refuge spaces is then allowed upon pressing the control button again at 0,3 m/s.

48

Page 49: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ControlsControls

Push buttons for inspection controls shall comply to EN 60947-5-1.

49

Inspection controls on the car top to have a “Run” button to act with up and down buttons.

Inspection controls on the car top to have a “Run” button to act with up and down buttons.

Page 50: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

ControlsControls

The lift shall be provided with a means to prevent the lift from answering to landing calls, to disable the automatic door operation and give at least terminal floor calls for maintenance.

Landing and Car Door By-pass Control

•It is now allowed to have a feature, accessible to authorized and competent persons only to by-pass the locking contacts for maintenance purposes.

The alarm is now specified as that of EN 81-2850

Page 51: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Traction Traction & Hydraulic & Hydraulic

DrivesDrives

51

Page 52: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Traction DrivesTraction Drives

Brake

The machine shall be capable of having the brake released by a continuous manual operation, even in the case of power supply failure. The operation can be mechanical (e.g. lever) or electrical by independent supply.

With the brake manually released and the car loaded at 80 % of the value of the balanced load of the car, it shall be possible to move the car to an adjacent floor:

52

Page 53: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Hydraulic DrivesHydraulic Drives

The dimensions and tolerances of the tubes used for the manufacture of the jack shall be according to the applicable standard of EN 10305 series.

Jack calculations have been amended to remove errors.

The restrictor and rupture valves shall be accessible for inspection directly from the car roof or from the pit.

53

Page 54: Effects on lift products by EN 81-1/2 re-drafting EN 81-20 / 50 Asansor Istanbul 2011 April 15 th, 2011 Istanbul Ian JONES Convenor CEN/ TC10/WG1.

Public CommentPublic CommentWhen the new draft standard is released for When the new draft standard is released for

public comment Turkey is encouraged to public comment Turkey is encouraged to provide its opinions on the new items through provide its opinions on the new items through

its partnership agreements with CEN.its partnership agreements with CEN.