EF Insulation Jackets
Click here to load reader
-
Upload
leigh-ridlington -
Category
Engineering
-
view
36 -
download
2
Transcript of EF Insulation Jackets
Enersol Flomar insulation jackets are an effective method of saving energy and reducing carbon emissions. By simply fitting our insulation jackets to your steam, condensate and hot water systems, we can reduce your costs and losses quickly and efficiently.
The payback in many cases is less than one year, with jackets that are easy to fit and can be removed without damage for routine maintenance.
Site Survey and Report:
• A typical site survey in England is in most cases free
• We identify all non-insulated pipe and equipment
• A detailed survey report is then issued listing costs and savings
Insulation Jacket Specifications:
• Constructed from high quality materials with a “Class O” rating in accordance with BS476 section 7
• Temperature range: 65°C to 250°C
• Double sided silicone coated glass cloth
• Available from stock – with the ability to make custom jackets quickly
• Tailored to fit the valve/flange ‘snugly’ whilst maintaining easy access
• They can reduce heat loss by as much as 90%
INSULATION JACKETS
Flomar Limited, Marlborough Drive, Fleckney, Leicestershire LE8 [email protected] Tel: +44(0)116 240 3430 www.enersolflomar.com
EFIJ1
INSULATION JACKETS
BEFORE AFTER
This picture shows the rear of the boiler before insulation.
This picture shows the rear of the boiler after the completion of insulation.
ITEM QTY DESCRIPTION S.A. EACH 1. 2. 3. 4. 5. LOCATION
1 1Boiler front 6 square meters
6.000 4234168.63 97307.60 4136861.03 £63.18 0.218352 Boiler number 1
2 1Boiler back 2 square meters
2.000 1411389.54 32435.87 1378953.68 £21.06 0.072784 Boiler number 1
9 5 2̎'' Valves 0.170 486357.21 13785.24 472571.96 £7.22 0.024943 Feed water inlet
10 2 2̎'' Flanges 0.310 354754.67 10055.12 344699.55 £5.26 0.018194 Feed water inlet
16 1Boiler front 6 square meters
6.000 4234168.63 97307.60 4136861.03 £63.18 0.218352 Boiler number 2
17 1Boiler back 2 square meters
2.000 1411389.54 32435.87 1378953.68 £21.06 0.072784 Boiler number 2
55 2 1'' Valves 0.260 297536.17 8433.33 289102.85 £4.42 0.015259 Condensate
56 1 1'' Strainer valve 0.195 111576.07 3162.50 108413.57 £1.66 0.005722 Condensate
Savings Per Week = £187.04 0.646390
Savings Per Annum = £9,352.22 32.319520
Example ReportQuote Number: Report 001:
Key:
Area Boiler House Steam 8 Barg
1. Energyloss Uninsulated in Kj/Week.
2. Energyloss insulated in Kj/Week. 3. Kj saved per week after insulation.
Area Boiler House Steam 8 Barg
4. Savings per week at an energy cost of £30.00 per Tonne of Steam.
5. Estimated CO2 savings per week in tonnes.