Ecole Sigtto Questionare
description
Transcript of Ecole Sigtto Questionare
Sigtto Questionnaire Page 1 of 18
Questions adopted from:
Ship Information Questionnaire
for Gas Carriers LPG/C ECOLE
Oil Companies International Marine Forum
Society of International Gas Tanker & Terminal Operators
Sigtto Questionnaire Page 2 of 18
Sigtto Questionnaire Page 3 of 18
B1 CARGO GENERAL INFORMATION 1.1 List products which the ship is certified to carry 1.2 Minimum allowable tank temperature 1.3 Maximum permissible tank pressure 1.4 List grades which can be loaded or
discharged simultaneously 1.5 List grades which can be transported simultaneously 1.6 Number of products that can be conditioned
by reliquefaction simultaneously
Ammonia N-Butane
I-Butane
Acetaldehyde
Butadiene
Butylene
Dimethylamine
Isopropylamine
Monoethylamine
Propane
Propylene
Vinyl Cloride (VCM)
Vinylethylether Isoprene Monomer Propylene Oxide
Iso-Pentane
Pentane
Pentene
Diethylether
-48 ºC
7,0 Barg
2
2
2
1.7 State natural tank segregations (NB. Separation must 2
be by the removal of spools or the insertion of blanks)
B2 CARGO TANK
2.1 Type and Materials of Cargo Tanks Independent Type "C", Fine Grain
2.2 Maximum Allowable Relief Valve 7,0 Barg
Settings
2.3 Safety Valve Set Pressure - if Variable 0,5 / 1,5 / 4,85 / 7,0 Barg
Give Range of Pilot Valves
2.4 Maximum Vacuum 50%
2.5 Maximum Cargo Density 0,970 3
T/m
2.6 Maximum rate of cool-down 5 ºC/hr
2.7 State any limitations regarding partially None
filled tanks
2.8 State allowable combinations of filled None
and empty tanks
Sigtto Questionnaire Page 4 of 18
B3 CARGO TANK CAPACITIES
Tank Capacity m 3 Butane Propane Ammonia Butadiene VCM
(100%) tonnes Cº tonnes Cº tonnes Cº tonnes Cº tonnes Cº tonnes Cº
1 1072 619 10,4 598 -33 704 -25 1001,6 -4
2 442 255 10 247 -33 290 -25 413 -4
3 1763 1019 10 985 -33 1159 -25 1648,36 -4
4
5
6
7
8
Totals 3277 1893 1830 2153 0 3062,96 0
B4 LOADING RATE
4.1 From Refrigerated
Storage Rate m3 /h
4.2 Product With Vapour Without Vapour
Return Return
4.3 Butane 450 450
4.4 Propane 450 300
4.5 Ammonia 460 320
Propylene
4.6 450 220
V.C.M.
450 450
4.7
Butadiene
450 450
4.8 From Pressure Storage
Rate m3 /h
Product
4.9 With Vapour Without Vapour
Return Return
4.10
Butane 0-30 450 450
4.11
Propane 0 500 330
4.12
Propane 10 330
4.13 Propane 20 135
Propane 30 95
4.14 Special Remarks
Sigtto Questionnaire Page 5 of 18
B5 DISCHARGING - GENERAL
Cargo Pumps
5.1 Type of pumps centrifugal Thune Eureka CL 80
5.2 Number per tank Tk 1&3: 2 Tk 2:1
5.3 Rate (per pump) 90 3
m /hr
5.4 Delivery head 120 mlc
5.5 Maximum density 0,970 3
MT/m
Booster Pump
5.6 Type of pump centrifugal Thune Eureka CP 80
5.7 Number 2
5.8 Rate (per pump) 180 3
m /hr
5.9 Delivery head 120 mlc
5.10 Maximum density 0,680 3
MT/m
Sigtto Questionnaire Page 6 of 18
B6 DISCHARGE PERFORMANCE
Full Cargo Discharge Times (using all main pumps)
6.1 Fully Propane - 40 ºC
Refrigerated:
Manifold Back
Hours*
With Vapour Without Vapour
6.2
Pressure
Return Return
6.3 1 Bar 10 10
6.4 5 Bar 10 10
10 Bar
15 15
*Indicate difference when manifold strainers are installed
6.5 Pressurized: Propane 0 ºC
Manifold Back
Hours
With Vapour Without Vapour
6.6
Pressure
Return Return
6.7 1 Bar 10 10
6.8 5 Bar 10 10
10 Bar
8,5 8,5
Tank no.
B7 UNPUMPABLES 3
1 2 3 4 5 6 7 8 Total m
7.1 Liquid 0,04 0,02 0,04 0 0 0 0 0 0,1
B8 VAPORISING UNPUMPABLE 8.1 Process used Hot Gas
Time to vaporise liquid unpumpables remaining after full cargo discharge
8.2 - Propane < 3 hrs
8.3 - Butane < 3 hrs
8.4 - Ammonia < 3 hrs
8.5 - Propylene < 3 hrs
8.6 - Butadiene < 3 hrs
8.7 - VCM < 3 hrs
Sigtto Questionnaire Page 7 of 18
B9 RELIQUEFACTION PLANT 9.1 Plant design conditions - Air Temperature +45 ºC
- Sea Temperature +32 ºC
Plant type 9.3 Single stage/direct
9.4 Two stage/direct
9.5 Simple Cascade
9.7 Coolant type Compressors
9.8 Type and Makers Name Sulzer K 105-2F
9.9 Number 3
9.10 Capacity (per unit) 425 3
m / hr
9.11 Are they Oil-Free
B10 COOLING CAPACITY
State Cooling Capacity for kcal/hr for -
10.1 Propane @ - 42 ºC kcal/hr
10.2 @ - 20 ºC 320000 kcal/hr
10.3 @ - 5 ºC kcal/hr
10.4 Butane @ -5 ºC kcal/hr
10.5 Propylene @ -20 ºC 480000 kcal/hr
10.6 Ammonia @ -15 ºC 600000 kcal/hr
Sigtto Questionnaire Page 8 of 18
B11 CARGO TEMPERATURE LOWERING CAPABILITY
(Time taken to lower the temperature of ...at sea with sea temperature + 15 ºC)
11.1 Propane from 18ºC to - 42ºC 166 hrs
11.2 from - 5ºC to - 42ºC 138 hrs
11.3 from - 38ºC to - 42ºC 30 hrs
11.4 from + 20 ºC to - 0,5 ºC 26 hrs
11.5 from + 10 ºC to - 0,5 ºC 12 hrs
11.6 Butane from + 20 ºC to - 0,5 ºC hrs
11.7 from + 10 ºC to - 0,5 ºC hrs
11.8 ISO Butane from + 10 ºC to - 5ºC hrs
11.9 Ammonia from 0ºC to -30ºC 130 hrs
11.10 Ammonia from -5 ºC to -30ºC 120 hrs
11.11 Ammonia from -25 ºC to -30ºC 36 hrs
11.12 Ammonia from 20ºC to -5ºC 42 hrs
B12 INERT GAS
Main I.G. Plant 12.1 Type of Plant 12.2 Capacity 12.3 Type of Fuel Used 12.4 Composition of IG 12.5 Lowest dewpopint achievable 12.6 Used for
Auxiliary I.G. or Nitrogen Plant 12.7 Type of System 12.8 Capacity 12.9 Composition of IG
(O2 - Co2 - Co - Nox - N2) 12.10 Lowest dewpoint achievable 12.11 Used for
Nitrogen 12.12 Liquid storage capacity: 12.13 Daily Boil-of loss 12.14 Maximum supply pressure: 12.15 Supply capacity 12.16 Used for 12.17 HP Nitrogen
Smit Ovens GIN/ST 350/310
I.G. 350, N2 210 m3/hr
MGO 0,3-14-200ppm-200ppm-Balance
-40 ºC
Gas freeing
m3/hr
ºC
0,5 m3
m3 200 Bar
m3/hr
nm3
Sigtto Questionnaire Page 9 of 18
Sigtto Questionnaire Page 10 of 18
B13 CARGO TANK INERTING / DE-INERTING
13.1 Time Taken From Fresh Air to Under 0,5% O2 at - 25 ºC Dewpoint 50 hrs
13.2 Time Taken From Cargo Vapour to Fully Inert at - 25 ºC Dewpoint when:
- I.G. density less than product 28 hrs
- I.G. density greater than product hrs
B14 GAS FREEING TO FRESH AIR
14.1 Plant used Inert gas and portable fans
14.2 Time taken from fully inerted condition to fully Approx 24 hrs
breathable fresh air
Sigtto Questionnaire Page 11 of 18
B15 CHANGING CARGO GRADES
15.1 Propane Butane Ammonia VCM
To
From Time I.G. Used Time I.G. Used Time I.G. Used Time I.G. Used
(Hours) (m3) (Hours) (m
3) (Hours) (m
3) (Hours) (m
3)
Propane 60 60 13000
Butane 60 60 13000
Ammonia 60 60 * 60
VCM 60 13000 60 13000 60
Note any operation that cannot be carried out at sea or any other comments:
* Restrictions may apply
B16 DECK TANK CAPACITIES
16.1 Propane capacity 3
m
16.2 Butane capacity 3
m
16.3 Ammonia capacity 3
m
16.4 Maximum Allowable Relief Valve Setting Barg
16.5 Lowest Permissible Temperature ºC
16.6 Materials
B17 PRE-LOADING COOLDOWN
In the table below, show time and quantity of coolant required to cooldown
cargo tanks from ambient temperature and fully gassed up state sufficient to
allow loading to commence.
Quantity of Time (Hours)
Product Coolant With Vapour Without
17.1 Required Return Line Return Line
Propane 33 Rate max 10
17.2
Butane 33 Rate max 10
17.3
Ammonia 33 Rate max 10
17.4
VCM 33 Rate max 10
Sigtto Questionnaire Page 12 of 18
B18 VAPORISER
18.1 Type of Vaporiser Re-heater
18.2 Number fitted 1
18.3 Capacity (per unit) - Propane 180 3
m /hr Vapour
18.4 Liquid supply rate 600 3
m /hr Liquid
18.5 Delivery temperature 5 ºC
18.6 Capacity (per unit) - Ammonia 3
m /hr Vapour
18.7 Liquid supply rate 3
m /hr Liquid
18.8 Delivery temperature ºC
18.9 Capacity (per unit) - Nitrogen 3
m /hr Vapour
18.10 Liquid supply rate 3
m /hr Liquid
18.11 Delivery temperature ºC
B19 BLOWER
19.1 Type of Blower I.G. plant
19.2 Rates capacity 350 3
m /hr
19.3 Delivery pressure 5 Barg
Sigtto Questionnaire Page 13 of 18
B20 CARGO RE-HEATER
20.1 Type of Re-Heater Villa Scambiatori
20.2 Number Fitted 1
20.3 Heating Medium Seawater
Discharge rates with sea water at 15º C
to raise product temperature
20.4 - for Propane from - 42º C to - 5º C 180 3
m /hr
20.5 - for Ammonia from - 33º C to 0º C 110 3
m /hr
20.6 Cargo Heater Curve
B21 HYDRATE CONTROL 21.1 Type of Depressant with Freezing Point Temperature -97,8 ºC
21.2 Quantity of Depressant carried litres 21.3 Means of injection Any
other system used
Sigtto Questionnaire Page 14 of 18
B22 CARGO MEASUREMENT
Level Gauges 22.1 Are level gauges 22.2 Manufacturer 22.3 Type 22.4 Rated Accuracy 22.5 Certifying Authority
Temperature Gauges 22.6 Manufacturer 22.7 Type 22.8 Rated Accuracy 22.9 Certifying Authority
Local Remote Enraf Nonius
806
dL=+- (2,5 + 0,18xL) mm
Class/Owner/Service Comp.
Eckardt
T1 174 19"
Class/Owner/Service Comp.
Pressure Gauges
22.10 Manufacturer Rosemount 22.11 Type 1151 GP
22.12 Rated Accuracy +- 0,25 %
22.13 Certifying Authority Class/Owner/Service Comp.
Oxygen Analyser 22.14 Manufacturer Teledyne
22.15 Type 320 P
Fixed Gas Analyser 22.16 Manufacturer Dräger
22.17 Type Exytron 5010
22.18 Are Cargo tank Calibration Tables Available
22.19 Measuring Company SGS
22.20 Certifying Company
22.21 Calibration Calculated to cm
22.22 Tables Established to mm
22.23 Trim and List Corrections Available
22.24 Temperature Corrections Available
22.25 Float Gauge Tape Corrections Available
Sigtto Questionnaire Page 15 of 18
B23 CARGO SAMPLING
23.1 Cargo Tank: 1 2 3 4 5 6 7 8
Sample Level
Top
Middle
Bottom
23.2 Can samples be drawn from -Tank Vapour Outlet
- Manifold Liquid Line
- Manifold Vapour Line
- Pump Discharge Line
23.3 State Connection Type and Size 1/2" NPT M
Sigtto Questionnaire Page 16 of 18
B24 CARGO MANIFOLD
Sigtto Questionnaire Page 17 of 18
B25 CARGO MANIFOLD REDUCER
State number of reducers carried on board and
their
flange rating and size:
25.1 ANSI Class 300 8" x 6", 6" x 4"
6" x 3"
4" x 2"PN25, 4" x 4"PN25
25.2 ANSI Class 300 to Class 150 8" x 6", 6" x 6", 4" x 2"
25.3 ANSI Class 150
6"/300 x 6" PN25
4"/300 x 4"PN16
6"/300 x 4"PN25
B26 CONNECTIONS TO SHORE FOR ESD AND COMMUNICATIONS SYSTEMS
26.1 Is ESD connection to Shore available
If Yes, which of the following systems are fitted:
Pneumatic
Electrical
Fibre Optic
26.2 Type of Plug Used:
Pneumatic
Electrical Electrical
Fibre Optic 26.3 Is Hose or Cables Available on
Board Specify Length
Pneumatic
Electrical 30
Fibre Optic 26.4 Is Connection Available for Telephone Line
26.5 Are Connections Available on Both Sides of Vessel
Sigtto Questionnaire Page 18 of 18
B27 MANIFOLD DERRICK / CRANE
27.1 Is Manifold Derrick Provided
27.2 Is Manifold Crane Provided
27.3 Is Lifting Equipment Same Port and Starboard If No, give details tonnes
27.4 State SWL at Maximum Outreach 0,9 tonnes
B28 STORES HANDLING
28.1 Stores Crane/Derrick Location and SWL Boatdeck
0,5 tonnes