ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a...

5
chutes ecol Kailash Engineering Manufactured by: 378, kothariya colony, 80 feet road, near sorathiyawadi circle, RAJKOT. GUJARAT. 360 002 cell: +91 9898 338 229, email: [email protected] I K

Transcript of ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a...

Page 1: ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a circular cross section. Ecol waste chute hoppers are factory fabricated with steel

chutesecol

K a i l a s hE n g i n e e r i n g

Manufactured by:

378, kothariya colony, 80 feet road, near sorathiyawadi circle, RAJKOT. GUJARAT. 360 002cell: +91 9898 338 229, email: [email protected]

K

Page 2: ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a circular cross section. Ecol waste chute hoppers are factory fabricated with steel

chutesElectronic Centralized Garbage Collection System, standard garbage, Linen And Debris Chutes.

ecol

INTRODUCTION:

Material Specifications:

Size Of Chute:

ECOL chutes are very appropriate, effortless and easy method of controllingand disposing of refuse and linen in high-rise buildings

ECOL chutes designed to meet the firm necessities of environmentalhealth and protection. The addition of chute is cleaning systems, sanitizing

and disinfecting units , fully electronic CPU system, and fire sprinklers.Within the overall design of chutes have significantly amplifies its usage

all over the world.

ECOL waste chutes are particularly designed for use in apartments, hotels,hospitals, condominiums, commercial complexes and shopping malls.In fact where waste needs controlling, moving and disposing effortlessly,quickly and tidily. It can be easily installed at any duct, lobby, staircase,

kitchens etc. In majority case waste chute is installed internally only,but ECOL chutes can be installed externally also in case of when chuteis to be installed afer building has been finished or pre provision for chute

is not given.

Advantages of installing garbage chute is that it assists whole building wasteat one point that is garbage room. Electronic chute will make possible to

divide DRY and WET garbage to its particular bins, it also helps to decreasemanpower.

We manufacture Ecol chutes from following material SS 430, SS 304. Which isnoncombustible for safety issue, other materials chute can be manufactured

on client request fibre and plastic are not recommended for safety issueof fire. We strongly advise the use of stainless steel for the waste chutes

because it has the benefit of being dead set against to the humidity, acid etc.It has no applied outside layer to wear off and most important has very

high impact strength. Thickness of the sheet can be1.2 mm, 1.5 mm, 2 mm,as required in different site

We provides a comprehensive series of waste chutes. The size of waste chutescan be 18” , 21”, 24”, 30”. Depends upon the height if building and

number of user..

Page 3: ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a circular cross section. Ecol waste chute hoppers are factory fabricated with steel

Size Of Chute:

Height of Chute:

Shape of chute:

Hoppers:

Size of hopper:

Hopper Finish:

We provides a comprehensive series of waste chutes. The size of waste chutescan be 18” , 21”, 24”, 30”. Depends upon the height if building and

number of user.

The height of the chute is varies according to individual building design. Weprovide chutes, from as small as 1 meter up to 165-170 meters, or according

to requirements of client.

To give an unobstructed free flow of all types of waste and garbage within achute, the best shape has proved to be globular, Ecol chutes therefore

have a circular cross section.

Ecol waste chute hoppers are factory fabricated with steel constructionSS 430, SS 202 or SS 304 sheets. It is designed to banish loose or bagged

waste and garbage directly into a chute. Hopper doors pivoted at bottomfor top opening. The door and equipped well for auto closing function.

Our hopper door silently and securely self closes after every operation and it isspecially designed to avert obstructions in using chute.

Size of hopper changes as diameter of chutes changes.Here are few common size mentioned used in our chute.

SIZE OF CHUTE HOPPER SIZE18” 12” x 15”21” 15” x 15”24” 15” x 18”27” 18” x 21”30” 21” x 24”

As it is made from Steel it ca be mirror , matt or brush finishas per client’s request.

chutesElectronic Centralized Garbage Collection System, standard garbage, Linen And Debris Chutes.

ecol

Page 4: ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a circular cross section. Ecol waste chute hoppers are factory fabricated with steel

Our sanitation system is exclusively premeditated to clean the entire verticallength of the inner surface of chutes. The system prefabricated as an

important element which is all set for instant installation on site.It is installed at roof level.

The sanitation system will clean the whole chute by switching in just one button,electric motorized valve will let the water to flow the over head tank.

Water will be sprayed from flushing spray in each floor, system will alsospray Disinfectants to whole chute. It also helps to one of the problem

associated with the use of chute’s strong odors. This process will help tokeep chute clean and hygienic. The system can be used manually also,this process is done from Control Panel Unit installed at the ground level

near to garbage discharge point. System can be programed automaticallyalso which will set to start and stop itself to clean the chute. The time can be

changed manually from Control Panel Unit easily.

State of art designed to separate more than one type of garbage from onesingle chute only. This system works to divide DRY and WET garbage to

its particular trolleys. More than two type of separations also possible for medicalwaste. It saves the cost of two different chutes and act as so multiple work

in single chute only.

This unit is connected to control panel from where it gets command to flap.Each door contains DRY and WET buttons, as DRY button is pressed fromone floor the electronic control panel will give command to Severanceunit and hence the unit will set itself to DRY mode and the garbage will

be disposed to DRY trolley. During this procedure all others floors door willremain locked until the process completes. Same procedure

will be repeated for WET garbage .

Computerized Programmed Sanitation system:

Role of sanitation system :

Severance unit:

How Severance unit works:

Glass bulb sprinklers are installed at every alternate floor for fire protection insidethe chute. Used sprinkler will be ½” IPS, 68°C

Fire Sprinklers:

chutesElectronic Centralized Garbage Collection System, standard garbage, Linen And Debris Chutes.

ecol

Page 5: ecol - 2.imimg.com · chute, the best shape has proved to be globular, Ecol chutes therefore have a circular cross section. Ecol waste chute hoppers are factory fabricated with steel

chutesElectronic Centralized Garbage Collection System, standard garbage, Linen And Debris Chutes.

ecol

The entire weight of chute is divided in each floor. We therefore use35 x 35 x 5mm or 40 x 40 x 4mm mild steel angle with a rigid, welded

construction which is directly anchor fastened to slab or beam in each floor.The design of frames varies as according to different site conditions

in each individual buildings.

Installed at the top of the chutes, this respirator maintains a smooth flow of freshair within the whole chute. The stinking air exhausted by fan, which prevents

the escape of any bad odors released from the garbage.

Electromagnetic door locking systems are used to improve the safety ofgarbage disposal chute systems it is appreciably improve and ensure

proper operation of intake doors. This arrangement prevents injury to operatingpersonnel by a falling bag should the chute be used simultaneously at two

different levels in disposal, for instance. This lock also act a leading role whenchute is with severance unit. When one floor is using the chute for DRY mode

the lock will not let open any other door at any floor.

This system is an additional system to add in sanitation unit. The system helpsa circular nylon brush automatically to fall and raise throughout the vertical

height of chute. The nylon brushes scrapes and cleans the inner surfaceof chute as they move down and up the chute.

Odor Control Unit is designed for reducing the odor generated in garbage rooms.As the garbage room is closed this odor needs to be controlled. An odor

control liquid is sprayed in very tiny ways which looks like gas form and it goesover the vent from garbage room to roof level and leaves a pleasant smell

throughout out the chute.

Floor supporting frames:

Exhaust system:

Electromagnetic strikers:

Additional accessories :

Nylon brushing system:

Odor control unit: