ECI

� Purpose� To protect the fuel� To provide cooling to the fuel after loss of

coolant accidents� Provide back-up to normal HTS cooling

during some none LOCA events

Page 3: ECI & NPC

Simplified ECI

Water Accumulator

GasAccumulator

ORWaterStorage

HighPressurePumps

ECI HeatExchanger

Recovery Pump

Recovery Sump

Page 4: ECI & NPC

LOCA

� Large� HTS voids rapidly� Fuel heats until ECI refills HTS� Ultimately recovery will cool fuel

� Small� Fuel cooled mostly by normal HTS path� Crash cool-down cools HTS� Recovery may be used

Page 5: ECI & NPC

Recovery Sump

Grade Level Storage Tank

Accumulator Water Tanks

Accumulator Gas Tanks

Storage Tank

ECI Header

Unit 5 Unit 6 Unit 8Unit 7

To Reactor Headers

Bruce

� High pressure� Low pressure� Recovery

OH #5OVH-28184-00006 R000

Three phases of injection

Page 6: ECI & NPC

Containment

� Purpose� Protective envelope that contains radioactive

material released from the heat transport system

� Minimize size and duration of an overpressure in containment following a LOCA

� Maintain containment sub-atmospheric following a LOCA

Page 7: ECI & NPC

Pressure Suppression Containment

Page 8: ECI & NPC

VacuumBuilding

Page 9: ECI & NPC

Tank 1

Tank 3

V4To Spent Fuel Bay Exhaust

V5 V2MV15

MV16AO

AO AO AO

AO

Upper Chamber

Main Chamber

MV1 MV2 MV3Main ChamberPumps

UpperChamberPumps

Vacuum Building Operation

Page 10: ECI & NPC

Vacuum Building

Relief Manifold

Pressure Relief DuctsFuelling Machine

Room

Reactor Vaults

5 6 7 8

Containment Envelope

Page 11: ECI & NPC

Air Locks and Transfer Chambers

� Allow access and egress from containment� 2 doors one of which must be properly

closed at all times� Correct procedure must be followed when

operating the doors

Page 12: ECI & NPC

8'

Vent Duct

APRV CV500

Isolation Valve MV501

Pressure Relief Valve #2

Pressure Relief Valve Manifold Floor

Vacuum Duct

Flap Valve

36" Diameter Pressure Relief Valve Bypass Pipe

PRV and APRV

Page 13: ECI & NPC

Pressure Relief Valves

Page 14: ECI & NPC

KPa(g)+7

+4

0-1

-2

-3

-5

Containment Pressure

Time

Page 15: ECI & NPC

Vault Cooling

� Normally used to maintain the vault temperature less than 40°C

� Sufficient capacity to condense steam from small LOCAs

Page 16: ECI & NPC

EFADS & PARMS

� Post accident mitigation systems� Emergency Filter Air Discharge System

� De-misters� HEPA filters� Charcoal filters� Fans

� Post Accident Radiation Monitoring System� Measures what we release after and accident

Page 17: ECI & NPC

Emergency water system EWS

� Not the same as emergency water storage system� EWST is the tank in the top of the vacuum building

� EWS� Purpose: a redundant source of cooling water for

decay heat removal in the event of a loss of the normal systems

� 3 pumps in Emergency Water & Power Supply Building

� Suction from the CCW discharge channel