12-lead Rest & Exercise ECG
EC Sense ECG System Exercise
BENEFITS WITH EC SENSE ECG SYSTEM EXERCISE
EC Sense ECG System Exercise is a cost-effective turn-key 12-lead PC-based ECG system for hospitals, private clinics, and other healthcare facilities. The system is designed to be easy to use and produce high quality ECG recordings.
The system consists of a mobile height adjustable trolley, medical panel PC (fanless) with 22” widescreen touch function display, a washable medical keyboard and communication via WLAN and Ethernet.
EASY TO USE
REFERRAL SUPPORT
ADD ONOPTIONS
EC Sense ECG System Exercise
PATIENT CONTROL
HIGH SIGNAL QUALITY
QUALITYCONTROL
12-lead Rest and Exercise ECG(Catalogue no: CN S-1-B-C-D-2-3-G-H)
Ver.1
8.12
.3
EASYWORKFLOW
EASY TO USE
EC Sense is characterized by its
simple and intuitive use, which
eliminates the risks for improper
use. The system is programmable
and follows the workflows defined
by the user and supports the user
in collecting correctly measured
data and control different types of
external equipment. The need for
training is minimal for the normal
user; yet the advanced user has
every opportunity to grow with the
system and use it to its full potential.
QUALITY CONTROL
To ensure analysis and storage of a high quality ECG trace
with limited or no noise or disturbances, a one-click quality
check is performed.
CONTROL OF IDENTIFIED PATIENT
The system controls the patient ID when connected to EC
Store in order to verifry that input values are correct and
exist. Depending on the country’s specific ID parameters,
the system can extract information from the ID and notify
external systems.
+
Streamline your digital workflow!
EASY WORKFLOW
The operator starts the test by choosing a protocol adapted to
the examination and is then led through the different phases of
the examination. Supplement examination data, such as event
markers and printouts, can easily be added. All data is shown
in a clear and concise way, and the same button is always
used to proceed. The entire examination is recorded for
aftertreatment and creating a final report.
RELIABLE RESULTS/HIGH SIGNAL QUALITY
The EC Sense Lexor ECG acquisition unit with a noise-
insensitive design contains a high quality, non-destructive
base line filter which effectively removes baseline drift with
minimal impact on the ECG signal and it is adapted for
exercise tests to achieve the best measurements possible.
This results in a high proportion of interpretable ECGs in a
short period of time.
BASE LINE FILTER
BASE LINE DRIFT - NO FILTER
• Vacuum systems• Ergospiromentry• Communication (for storage)• Caliper (extended measurement)• Automatic blood pressure measurement
VARIOUS ADD ON EXAMINATION OPTIONS
To further increase the fields of application, various external
equipment can be connected to the EC Sense ECG system as
well as more in depth examination functionalities. The chosen
add on options are added to the EC Sense system without
the need for any hardware or software upgrade, and the new
function is available immediately.
+ + ...+
REFERRAL SUPPORT
The entire examination is stored for finishing and creating
a final report, and the system supports referral flow with
templates and notification to hospital information systems.
• EC Maintenance (for preventive maintenance and troubleshooting)
Cardiolex Medical AB
Vretenvägen 6, SE-171 54 Solna
+46 (0) 8 564 820 50 ∙ [email protected]
Cardiolex Medical AB develops and markets easy to use systems for ECG.
Our ECG management system and various ECG systems exist on 2/3 of Swedish hospitals, which means that
the system has over 10 000 users in Sweden. We offer the complete solution within ECG, from the systems
receiving the ECG signal from the patient to the ECG management systems, storing and managing generated
data. Our products work for a wide range of users, from University hospitals to small clinics. Our focus is on
creating ECG solutions that are user-friendly, reliable and secure.
Read more about our products on www.cardiolex.se.
Sampling frequency: 2000 sample/s in all leads.
Resolution: 22 bits, 0,15 μV LSB.
DC range: ± 450 mV.
Frequency range: 0,05–500 Hz.
Input impedance: > 10 MΩ.
Lead fail: Individual detection.
Leads: 12.
Configuration of leads: Standard and Cabrera.
Electrode placement: Standard or pediatric (V4R).
Pacemaker: Detection in all leads.
Line filter: 50/60 Hz.
Tremor filter: 35/75/100/150 Hz.
Baseline filter 1: 0,05 Hz.
Baseline filter 2: Correcting.
Filter presentation: Possible to view filtered and corrected data simultaneously.
Interpretation (Rest ECG): Automatic analysis, developed by Glasgow Royal Infirmary (GRI) (option); Median beat
calculation; Measurements; Adult and pediatric; Texts in native language.
Prints: Portrait/landscape; Any Windows compatible printer; PDF file (optional).
Communication: Windows’ network communication (TCP/IP); Bi-directional communication with EC Store (optional);
Export of Cardiolex XML (Cardiolex format) (optional); Communication to other systems (DataMedFT, DICOM, HL7
aECG, SCP) (optional); Export of PDF report (optional).
Certificates: ISO 13485, IEC 60601–1, IEC 60601–1–2, IEC 60601–2–25, IEC 60601–4; MDD class IIB; Defibrillation-
proof; Type CF; Enclosure and circuit board have flame class UL 94 V–2; CE no. 41315416.
PC type: e-medicTM Silence TP.
Operating system: Microsoft Windows 7®, .NET 4.
PC performance: Intel® CoreTM i5-3317U 1.7 GHz, 128 GB SSD, primary memory 8GB DDR3 RAM; Screen resolution
1920x1080; Touch screen.
PC information: 1 isolated USB, 4 USB 2.0, 3 isolated RS232, 1 Rs232.
Trolley: Height adjustable ITD Pro-cart.
Patient cables: Trunk cable 2 m or 4 m; Chest leads 1,0 m; Limb leads 1,2 m; Grabber contacts or banana contacts.
External equipment: Ergometers (Rodby, Monark, Ergoline, Lode etc.) communicating with Ergoline protocol;
Treadmills (Rodby, Lode etc.) communicating with Trackmaster protocol.
TECHNICAL DATA FOR EC SENSE ECG SYSTEM EXERCISE