PUMP Type UE-MINI EBARA Variable Speed Booster System Uniquely Uniquely Custom built for ideal water supply system... FEATURES APPLICATIONS Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings. Industrial water boosting. Municipal water supply. Irrigation. General pressure boosting application. VFD-4000 Series Controller Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time. Energy saving The use of inverter makes energy saving possible. Compact design Space saving and light weight, permitting easy installation. No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter. Simple to use User-friendly controller unit that accepts minimum setting data for optional operation. System EBARA VFD-4500 Series Controller

Transcript of EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000...

Page 1: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI

PUMP

Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely

Custom built for ideal water supply system...

FEATURES

APPLICATIONS

• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.

* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.

TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX

TYPE : 2UEM-EVM

TYPE : 2UEM-3M

81200 7705502UEM-CDX

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200

BSP50 5081200 770620 BSP50 50

W720

100

L

100 350

125

TANK

H

VIEW `X' SIDE VIEW

SUCTION

DISCHARGE X

ELCB

ON

40A DP

181200700 8702UEM-3M32

2UEM-3M65

2UEM-3M50

2UEM-3M40

870 18

870

870

18

18

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION DISCHARGE

MANIFOLD (mm)PIPE

CONNECTION

65 50

6580

80 65

100 80

BSP

BSP

BSP

BSP

1200

1200

1200

700

700

700

125

L

500100 100820

W

XH

VIEW `X' SIDE VIEW

DISCHARGE

SUCTION

YR B

ELCB

40A 4P

81200 7707002UEM-MATRIX 3MODEL

DIMENSIONmmmm

LmmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8

120012001200

BSPBSPBSP

TANK

100

L

100500

125

W720

H

SIDE VIEW

SUCTION

DISCHARGE

X

VIEW `X'

40A DP

ON

ELCB

MODELW TANKHLDIMENSION

mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24

MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE

CONNECTIONPIPE

BSPBSPBSP

FLANGEFLANGEFLANGEFLANGE

50 5065 65

50 50

80 80100 100100 100150 150

120012001200120012001200

X

TANK

L W

TANK

125

H

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

SUCTION DISCHARGE

`X' VIEW ELEVATION VIEW

40A 4P

ELCB

BR Y

DIMENSION DIMENSION

• Municipal water supply.• Irrigation.• General pressure boosting application.

VFD-4000 SeriesController

• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.

SystemEBARA

SystemEBARASystemEBARA

VFD-4500 SeriesController

EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my

EPM UE-MINI 0118

Authorised dealer:

Page 2: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI UE-MINI

• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)

• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.

SPECIFICATIONS SYSTEM OPERATION DIAGRAM

SYSTEM OPERATION DIAGRAM

PERFORMANCE CURVE

KEY FUNCTIONS

0 50 100 0

500450400250 300150 200 350

10

20

30

40

CURVES 2 POLES 50 Hz

50m

UE MINI CDX 70 / 90 / 120 / 200

UE MINI CDX 70 / 90 / 120 / 200

l/min

UE MINI CDX 70 UE MINI CDX 120

UE MINI CDX 90

UE MINI CDX 200

0 100 2000

900800500 600300 400 700

20

40

60

80

CURVES 2 POLES 50 Hz

120UE MINI MATRIX 3, 5, 10, 18

UE MINI MATRIX 3, 5, 10, 18

l/min1000

100

m

UE MINI MATRIX 18

UE MINI MATRIX 10

UE MINI MATRIX 5UE MINI M

ATRIX 3

0 400 8000

4000360032002000 24001200 1600 2800

10

20

30

40

CURVES 2 POLES 50 Hz

50

UE MINI 3M 32 / 40 / 50 / 65

UE MINI 3M 32 / 40/ 50 / 65

l/min

60

70

4400 4800

80m

UE MINI 3M 65

UE MINI 3M 40UE MINI 3M 50

UE MINI 3M

32

0 10 200

50 6030 40 70

50

100

CURVES 2 POLES 50 Hz

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

m3/hr

150

200

250

300

10080 180

m350

120 140 160

UE M

INI EVM

G 3

UE M

INI EVM

G 5

UE MINI EVMG 18

UE MINI EVMG 32

UE MINI EVMG 45

UE MINI EVMG 10

UE MINI EVMG 64

INVControl Signal

AC Power

M2

M3

M4

Floatless Relay or/ Pressure Output

Model : UE-MINI (T Series)

Control Signal

AC Power

* Up To 4 Inverter Pump System

M1

M2

M3

M4

INV

* Up To 4 Pump System

(Single Inverter type)

Model : UE-MINI (TD Series) (Multiple Inverter type)

(Control)

Floatless Relay or/ Pressure Output(Control)

Control Signal

AC Power

Model : UE-MINI (Multiple Inverter type)

* Up To 4 Inverter Pump System

M1

M2

M4

PressureOutput(Control)

M3

INV

INV

INV

INV

M1

INV

INV

INV

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.

- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.

• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.

• Option: Float less Relay control for Tank to Tank pumping application

SystemEBARA SystemEBARA SystemEBARA

UE-MINIType 2UEM-CDX120

Page 3: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI UE-MINI

• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)

• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.

SPECIFICATIONS SYSTEM OPERATION DIAGRAM

SYSTEM OPERATION DIAGRAM

PERFORMANCE CURVE

KEY FUNCTIONS

0 50 100 0

500450400250 300150 200 350

10

20

30

40

CURVES 2 POLES 50 Hz

50m

UE MINI CDX 70 / 90 / 120 / 200

UE MINI CDX 70 / 90 / 120 / 200

l/min

UE MINI CDX 70 UE MINI CDX 120

UE MINI CDX 90

UE MINI CDX 200

0 100 2000

900800500 600300 400 700

20

40

60

80

CURVES 2 POLES 50 Hz

120UE MINI MATRIX 3, 5, 10, 18

UE MINI MATRIX 3, 5, 10, 18

l/min1000

100

m

UE MINI MATRIX 18

UE MINI MATRIX 10

UE MINI MATRIX 5UE MINI M

ATRIX 3

0 400 8000

4000360032002000 24001200 1600 2800

10

20

30

40

CURVES 2 POLES 50 Hz

50

UE MINI 3M 32 / 40 / 50 / 65

UE MINI 3M 32 / 40/ 50 / 65

l/min

60

70

4400 4800

80m

UE MINI 3M 65

UE MINI 3M 40

UE MINI 3M 50

UE MINI 3M

32

0 10 200

50 6030 40 70

50

100

CURVES 2 POLES 50 Hz

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

m3/hr

150

200

250

300

10080 180

m350

120 140 160

UE M

INI EVM

G 3

UE M

INI EVM

G 5

UE MINI EVMG 18

UE MINI EVMG 32

UE MINI EVMG 45

UE MINI EVMG 10

UE MINI EVMG 64

INVControl Signal

AC Power

M2

M3

M4

Floatless Relay or/ Pressure Output

Model : UE-MINI (T Series)

Control Signal

AC Power

* Up To 4 Inverter Pump System

M1

M2

M3

M4

INV

* Up To 4 Pump System

(Single Inverter type)

Model : UE-MINI (TD Series) (Multiple Inverter type)

(Control)

Floatless Relay or/ Pressure Output(Control)

Control Signal

AC Power

Model : UE-MINI (Multiple Inverter type)

* Up To 4 Inverter Pump System

M1

M2

M4

PressureOutput(Control)

M3

INV

INV

INV

INV

M1

INV

INV

INV

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.

- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.

• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.

• Option: Float less Relay control for Tank to Tank pumping application

SystemEBARA SystemEBARA SystemEBARA

UE-MINIType 2UEM-CDX 90/10/0.75

Page 4: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI UE-MINI

• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)

• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.

SPECIFICATIONS SYSTEM OPERATION DIAGRAM

SYSTEM OPERATION DIAGRAM

PERFORMANCE CURVE

KEY FUNCTIONS

0 50 100 0

500450400250 300150 200 350

10

20

30

40

CURVES 2 POLES 50 Hz

50m

UE MINI CDX 70 / 90 / 120 / 200

UE MINI CDX 70 / 90 / 120 / 200

l/min

UE MINI CDX 70 UE MINI CDX 120

UE MINI CDX 90

UE MINI CDX 200

0 100 2000

900800500 600300 400 700

20

40

60

80

CURVES 2 POLES 50 Hz

120UE MINI MATRIX 3, 5, 10, 18

UE MINI MATRIX 3, 5, 10, 18

l/min1000

100

m

UE MINI MATRIX 18

UE MINI MATRIX 10

UE MINI MATRIX 5UE MINI M

ATRIX 3

0 400 8000

4000360032002000 24001200 1600 2800

10

20

30

40

CURVES 2 POLES 50 Hz

50

UE MINI 3M 32 / 40 / 50 / 65

UE MINI 3M 32 / 40/ 50 / 65

l/min

60

70

4400 4800

80m

UE MINI 3M 65

UE MINI 3M 40

UE MINI 3M 50

UE MINI 3M

32

0 10 200

50 6030 40 70

50

100

CURVES 2 POLES 50 Hz

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

UE MINI EVMG 3, 5, 10, 18, 32, 45, 64

m3/hr

150

200

250

300

10080 180

m350

120 140 160

UE M

INI EVM

G 3

UE M

INI EVM

G 5

UE MINI EVMG 18

UE MINI EVMG 32

UE MINI EVMG 45

UE MINI EVMG 10

UE MINI EVMG 64

INVControl Signal

AC Power

M2

M3

M4

Floatless Relay or/ Pressure Output

Model : UE-MINI (T Series)

Control Signal

AC Power

* Up To 4 Inverter Pump System

M1

M2

M3

M4

INV

* Up To 4 Pump System

(Single Inverter type)

Model : UE-MINI (TD Series) (Multiple Inverter type)

(Control)

Floatless Relay or/ Pressure Output(Control)

Control Signal

AC Power

Model : UE-MINI (Multiple Inverter type)

* Up To 4 Inverter Pump System

M1

M2

M4

PressureOutput(Control)

M3

INV

INV

INV

INV

M1

INV

INV

INV

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

RUN MODE

STOP

ENTER

Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.

- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.

• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.

- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code

- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.

Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.

• Option: Float less Relay control for Tank to Tank pumping application

SystemEBARA SystemEBARA SystemEBARA

UE-MINIType 2UEM-CDX120

Page 5: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI

PUMP

Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely

Custom built for ideal water supply system...

FEATURES

APPLICATIONS

• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.

* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.

TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX

TYPE : 2UEM-EVM

TYPE : 2UEM-3M

81200 7705502UEM-CDX

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200

BSP50 5081200 770620 BSP50 50

W720

100

L

100 350

125

TANK

H

VIEW `X' SIDE VIEW

SUCTION

DISCHARGE X

ELCB

ON

40A DP

181200700 8702UEM-3M32

2UEM-3M65

2UEM-3M50

2UEM-3M40

870 18

870

870

18

18

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION DISCHARGE

MANIFOLD (mm)PIPE

CONNECTION

65 50

6580

80 65

100 80

BSP

BSP

BSP

BSP

1200

1200

1200

700

700

700

125

L

500100 100820

W

XH

VIEW `X' SIDE VIEW

DISCHARGE

SUCTION

YR B

ELCB

40A 4P

81200 7707002UEM-MATRIX 3MODEL

DIMENSIONmmmm

LmmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8

120012001200

BSPBSPBSP

TANK

100

L

100500

125

W720

H

SIDE VIEW

SUCTION

DISCHARGE

X

VIEW `X'

40A DP

ON

ELCB

MODELW TANKHLDIMENSION

mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24

MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE

CONNECTIONPIPE

BSPBSPBSP

FLANGEFLANGEFLANGEFLANGE

50 5065 65

50 50

80 80100 100100 100150 150

120012001200120012001200

X

TANK

L W

TANK

125

H

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

SUCTION DISCHARGE

`X' VIEW ELEVATION VIEW

40A 4P

ELCB

BR Y

DIMENSION DIMENSION

• Municipal water supply.• Irrigation.• General pressure boosting application.

VFD-4000 SeriesController

• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.

SystemEBARA

SystemEBARASystemEBARA

VFD-4500 SeriesController

EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my

EPM UE-MINI 0118

Authorised dealer:

Page 6: EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000 Series Controller • ... - Booster unit incorporated with multiple pumps with integral

UE-MINIUE-MINI

PUMP

Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely

Custom built for ideal water supply system...

FEATURES

APPLICATIONS

• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.

* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.

TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX

TYPE : 2UEM-EVM

TYPE : 2UEM-3M

81200 7705502UEM-CDX

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200

BSP50 5081200 770620 BSP50 50

W720

100

L

100 350

125

TANK

H

VIEW `X' SIDE VIEW

SUCTION

DISCHARGE X

ELCB

ON

40A DP

181200700 8702UEM-3M32

2UEM-3M65

2UEM-3M50

2UEM-3M40

870 18

870

870

18

18

MODELDIMENSION

mmmmL

mmH TANK

LITREW

MANIFOLD (mm)SUCTION DISCHARGE

MANIFOLD (mm)PIPE

CONNECTION

65 50

6580

80 65

100 80

BSP

BSP

BSP

BSP

1200

1200

1200

700

700

700

125

L

500100 100820

W

XH

VIEW `X' SIDE VIEW

DISCHARGE

SUCTION

YR B

ELCB

40A 4P

81200 7707002UEM-MATRIX 3MODEL

DIMENSIONmmmm

LmmH TANK

LITREW

MANIFOLD (mm)SUCTION

MANIFOLD (mm)DISCHARGE PIPE

CONNECTIONBSP50 50

2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8

120012001200

BSPBSPBSP

TANK

100

L

100500

125

W720

H

SIDE VIEW

SUCTION

DISCHARGE

X

VIEW `X'

40A DP

ON

ELCB

MODELW TANKHLDIMENSION

mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24

MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE

CONNECTIONPIPE

BSPBSPBSP

FLANGEFLANGEFLANGEFLANGE

50 5065 65

50 50

80 80100 100100 100150 150

120012001200120012001200

X

TANK

L W

TANK

125

H

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

EMERGENCYFAULTSTOPRUN

Variable Frequency Drive

ENTERMODERUN

STOP

SUCTION DISCHARGE

`X' VIEW ELEVATION VIEW

40A 4P

ELCB

BR Y

DIMENSION DIMENSION

• Municipal water supply.• Irrigation.• General pressure boosting application.

VFD-4000 SeriesController

• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.

SystemEBARA

SystemEBARASystemEBARA

VFD-4500 SeriesController

EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my

EPM UE-MINI 0118

Authorised dealer: