EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000...
Transcript of EBARA UE-MINI UE-MINI PUMPebara.com.my/pic/product/upload/5_3_EBARA UE-MINI 0118.pdf · VFD-4000...
UE-MINIUE-MINI
PUMP
Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely
Custom built for ideal water supply system...
FEATURES
APPLICATIONS
• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.
* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.
TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX
TYPE : 2UEM-EVM
TYPE : 2UEM-3M
81200 7705502UEM-CDX
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200
BSP50 5081200 770620 BSP50 50
W720
100
L
100 350
125
TANK
H
VIEW `X' SIDE VIEW
SUCTION
DISCHARGE X
ELCB
ON
40A DP
181200700 8702UEM-3M32
2UEM-3M65
2UEM-3M50
2UEM-3M40
870 18
870
870
18
18
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION DISCHARGE
MANIFOLD (mm)PIPE
CONNECTION
65 50
6580
80 65
100 80
BSP
BSP
BSP
BSP
1200
1200
1200
700
700
700
125
L
500100 100820
W
XH
VIEW `X' SIDE VIEW
DISCHARGE
SUCTION
YR B
ELCB
40A 4P
81200 7707002UEM-MATRIX 3MODEL
DIMENSIONmmmm
LmmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8
120012001200
BSPBSPBSP
TANK
100
L
100500
125
W720
H
SIDE VIEW
SUCTION
DISCHARGE
X
VIEW `X'
40A DP
ON
ELCB
MODELW TANKHLDIMENSION
mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24
MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE
CONNECTIONPIPE
BSPBSPBSP
FLANGEFLANGEFLANGEFLANGE
50 5065 65
50 50
80 80100 100100 100150 150
120012001200120012001200
X
TANK
L W
TANK
125
H
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
SUCTION DISCHARGE
`X' VIEW ELEVATION VIEW
40A 4P
ELCB
BR Y
DIMENSION DIMENSION
• Municipal water supply.• Irrigation.• General pressure boosting application.
VFD-4000 SeriesController
• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.
SystemEBARA
SystemEBARASystemEBARA
VFD-4500 SeriesController
EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my
EPM UE-MINI 0118
Authorised dealer:
UE-MINIUE-MINI UE-MINI
• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)
• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.
SPECIFICATIONS SYSTEM OPERATION DIAGRAM
SYSTEM OPERATION DIAGRAM
PERFORMANCE CURVE
KEY FUNCTIONS
0 50 100 0
500450400250 300150 200 350
10
20
30
40
CURVES 2 POLES 50 Hz
50m
UE MINI CDX 70 / 90 / 120 / 200
UE MINI CDX 70 / 90 / 120 / 200
l/min
UE MINI CDX 70 UE MINI CDX 120
UE MINI CDX 90
UE MINI CDX 200
0 100 2000
900800500 600300 400 700
20
40
60
80
CURVES 2 POLES 50 Hz
120UE MINI MATRIX 3, 5, 10, 18
UE MINI MATRIX 3, 5, 10, 18
l/min1000
100
m
UE MINI MATRIX 18
UE MINI MATRIX 10
UE MINI MATRIX 5UE MINI M
ATRIX 3
0 400 8000
4000360032002000 24001200 1600 2800
10
20
30
40
CURVES 2 POLES 50 Hz
50
UE MINI 3M 32 / 40 / 50 / 65
UE MINI 3M 32 / 40/ 50 / 65
l/min
60
70
4400 4800
80m
UE MINI 3M 65
UE MINI 3M 40UE MINI 3M 50
UE MINI 3M
32
0 10 200
50 6030 40 70
50
100
CURVES 2 POLES 50 Hz
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
m3/hr
150
200
250
300
10080 180
m350
120 140 160
UE M
INI EVM
G 3
UE M
INI EVM
G 5
UE MINI EVMG 18
UE MINI EVMG 32
UE MINI EVMG 45
UE MINI EVMG 10
UE MINI EVMG 64
INVControl Signal
AC Power
M2
M3
M4
Floatless Relay or/ Pressure Output
Model : UE-MINI (T Series)
Control Signal
AC Power
* Up To 4 Inverter Pump System
M1
M2
M3
M4
INV
* Up To 4 Pump System
(Single Inverter type)
Model : UE-MINI (TD Series) (Multiple Inverter type)
(Control)
Floatless Relay or/ Pressure Output(Control)
Control Signal
AC Power
Model : UE-MINI (Multiple Inverter type)
* Up To 4 Inverter Pump System
M1
M2
M4
PressureOutput(Control)
M3
INV
INV
INV
INV
M1
INV
INV
INV
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.
- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.
• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.
• Option: Float less Relay control for Tank to Tank pumping application
SystemEBARA SystemEBARA SystemEBARA
UE-MINIType 2UEM-CDX120
UE-MINIUE-MINI UE-MINI
• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)
• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.
SPECIFICATIONS SYSTEM OPERATION DIAGRAM
SYSTEM OPERATION DIAGRAM
PERFORMANCE CURVE
KEY FUNCTIONS
0 50 100 0
500450400250 300150 200 350
10
20
30
40
CURVES 2 POLES 50 Hz
50m
UE MINI CDX 70 / 90 / 120 / 200
UE MINI CDX 70 / 90 / 120 / 200
l/min
UE MINI CDX 70 UE MINI CDX 120
UE MINI CDX 90
UE MINI CDX 200
0 100 2000
900800500 600300 400 700
20
40
60
80
CURVES 2 POLES 50 Hz
120UE MINI MATRIX 3, 5, 10, 18
UE MINI MATRIX 3, 5, 10, 18
l/min1000
100
m
UE MINI MATRIX 18
UE MINI MATRIX 10
UE MINI MATRIX 5UE MINI M
ATRIX 3
0 400 8000
4000360032002000 24001200 1600 2800
10
20
30
40
CURVES 2 POLES 50 Hz
50
UE MINI 3M 32 / 40 / 50 / 65
UE MINI 3M 32 / 40/ 50 / 65
l/min
60
70
4400 4800
80m
UE MINI 3M 65
UE MINI 3M 40
UE MINI 3M 50
UE MINI 3M
32
0 10 200
50 6030 40 70
50
100
CURVES 2 POLES 50 Hz
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
m3/hr
150
200
250
300
10080 180
m350
120 140 160
UE M
INI EVM
G 3
UE M
INI EVM
G 5
UE MINI EVMG 18
UE MINI EVMG 32
UE MINI EVMG 45
UE MINI EVMG 10
UE MINI EVMG 64
INVControl Signal
AC Power
M2
M3
M4
Floatless Relay or/ Pressure Output
Model : UE-MINI (T Series)
Control Signal
AC Power
* Up To 4 Inverter Pump System
M1
M2
M3
M4
INV
* Up To 4 Pump System
(Single Inverter type)
Model : UE-MINI (TD Series) (Multiple Inverter type)
(Control)
Floatless Relay or/ Pressure Output(Control)
Control Signal
AC Power
Model : UE-MINI (Multiple Inverter type)
* Up To 4 Inverter Pump System
M1
M2
M4
PressureOutput(Control)
M3
INV
INV
INV
INV
M1
INV
INV
INV
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.
- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.
• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.
• Option: Float less Relay control for Tank to Tank pumping application
SystemEBARA SystemEBARA SystemEBARA
UE-MINIType 2UEM-CDX 90/10/0.75
UE-MINIUE-MINI UE-MINI
• 0.75 to 2.2kw, 1PH / 230V / 50Hz input.• V/F control.• Pressure control function.• Option: 3PH/415V/50Hz (for 0.75kW to 37 kW)
• Duty pressure point setting Ensure constant pressure operation.• Fully automatic operation Suitable for most pressure boosting requirement.• Faulty pump skip function No interruption operation, at all time.• Automatic re-start Storage of operational data even during sudden or unexpected power failure situation, ensure auto-start when power supply resumed.• Dry running protection Protection of pump unit during low water level or no-flow condition.• Simple data display Display operating data and provide alarm data where applicable.
SPECIFICATIONS SYSTEM OPERATION DIAGRAM
SYSTEM OPERATION DIAGRAM
PERFORMANCE CURVE
KEY FUNCTIONS
0 50 100 0
500450400250 300150 200 350
10
20
30
40
CURVES 2 POLES 50 Hz
50m
UE MINI CDX 70 / 90 / 120 / 200
UE MINI CDX 70 / 90 / 120 / 200
l/min
UE MINI CDX 70 UE MINI CDX 120
UE MINI CDX 90
UE MINI CDX 200
0 100 2000
900800500 600300 400 700
20
40
60
80
CURVES 2 POLES 50 Hz
120UE MINI MATRIX 3, 5, 10, 18
UE MINI MATRIX 3, 5, 10, 18
l/min1000
100
m
UE MINI MATRIX 18
UE MINI MATRIX 10
UE MINI MATRIX 5UE MINI M
ATRIX 3
0 400 8000
4000360032002000 24001200 1600 2800
10
20
30
40
CURVES 2 POLES 50 Hz
50
UE MINI 3M 32 / 40 / 50 / 65
UE MINI 3M 32 / 40/ 50 / 65
l/min
60
70
4400 4800
80m
UE MINI 3M 65
UE MINI 3M 40
UE MINI 3M 50
UE MINI 3M
32
0 10 200
50 6030 40 70
50
100
CURVES 2 POLES 50 Hz
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
UE MINI EVMG 3, 5, 10, 18, 32, 45, 64
m3/hr
150
200
250
300
10080 180
m350
120 140 160
UE M
INI EVM
G 3
UE M
INI EVM
G 5
UE MINI EVMG 18
UE MINI EVMG 32
UE MINI EVMG 45
UE MINI EVMG 10
UE MINI EVMG 64
INVControl Signal
AC Power
M2
M3
M4
Floatless Relay or/ Pressure Output
Model : UE-MINI (T Series)
Control Signal
AC Power
* Up To 4 Inverter Pump System
M1
M2
M3
M4
INV
* Up To 4 Pump System
(Single Inverter type)
Model : UE-MINI (TD Series) (Multiple Inverter type)
(Control)
Floatless Relay or/ Pressure Output(Control)
Control Signal
AC Power
Model : UE-MINI (Multiple Inverter type)
* Up To 4 Inverter Pump System
M1
M2
M4
PressureOutput(Control)
M3
INV
INV
INV
INV
M1
INV
INV
INV
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
RUN MODE
STOP
ENTER
Operation Functional Features• UE-Mini (Multi Inverter type) System - Booster unit incorporated with multiple pumps with integral inverter up to 4 pumps parallel in operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- Graphical display controller with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code.
- Dry running prevention, high & low pressure limit protection, pipe friction loss compensation and fix prevention function.
• UE-Mini (T-Series) System - Booster unit incorporated with 1 single external inverter driven pump and 3 fix speed pump or/ 4 fixed pumps with 1 floating inverter driven up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
• UE-Mini (TD-Series) System - Booster unit incorporated with multi external inverter driven pump up to 4 pumps in parallel operation and capable to adjust the water pressure automatically to meets actual system demand at all time.
- User friend and simplest key pad display with password protection provided and prevents any non-authorities personnel erroneous operation or/ overwriting of parameter function code
- Dry running prevention, high & low pressure limit protection and control of maximum start/stop operation.
Input Signal & Type of Sensor• Constant Pressure control installation: Industrial pressure transmitter with 0 to 20mA , 4 to 20mA(0-30V supply voltage) or/ 0-10 input signal.
• Option: Float less Relay control for Tank to Tank pumping application
SystemEBARA SystemEBARA SystemEBARA
UE-MINIType 2UEM-CDX120
UE-MINIUE-MINI
PUMP
Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely
Custom built for ideal water supply system...
FEATURES
APPLICATIONS
• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.
* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.
TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX
TYPE : 2UEM-EVM
TYPE : 2UEM-3M
81200 7705502UEM-CDX
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200
BSP50 5081200 770620 BSP50 50
W720
100
L
100 350
125
TANK
H
VIEW `X' SIDE VIEW
SUCTION
DISCHARGE X
ELCB
ON
40A DP
181200700 8702UEM-3M32
2UEM-3M65
2UEM-3M50
2UEM-3M40
870 18
870
870
18
18
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION DISCHARGE
MANIFOLD (mm)PIPE
CONNECTION
65 50
6580
80 65
100 80
BSP
BSP
BSP
BSP
1200
1200
1200
700
700
700
125
L
500100 100820
W
XH
VIEW `X' SIDE VIEW
DISCHARGE
SUCTION
YR B
ELCB
40A 4P
81200 7707002UEM-MATRIX 3MODEL
DIMENSIONmmmm
LmmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8
120012001200
BSPBSPBSP
TANK
100
L
100500
125
W720
H
SIDE VIEW
SUCTION
DISCHARGE
X
VIEW `X'
40A DP
ON
ELCB
MODELW TANKHLDIMENSION
mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24
MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE
CONNECTIONPIPE
BSPBSPBSP
FLANGEFLANGEFLANGEFLANGE
50 5065 65
50 50
80 80100 100100 100150 150
120012001200120012001200
X
TANK
L W
TANK
125
H
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
SUCTION DISCHARGE
`X' VIEW ELEVATION VIEW
40A 4P
ELCB
BR Y
DIMENSION DIMENSION
• Municipal water supply.• Irrigation.• General pressure boosting application.
VFD-4000 SeriesController
• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.
SystemEBARA
SystemEBARASystemEBARA
VFD-4500 SeriesController
EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my
EPM UE-MINI 0118
Authorised dealer:
UE-MINIUE-MINI
PUMP
Type UE-MINIEBARA Variable Speed Booster SystemUniquelyUniquely
Custom built for ideal water supply system...
FEATURES
APPLICATIONS
• Water supply for villas, schools, hotels, Hospitals, rest houses and high-rise buildings.• Industrial water boosting.
* All specifications are subject to change without prior notice.* Dimensional details are provided for reference only.
TYPE : 2UEM-CDX/2CDX TYPE : 2UEM-MATRIX
TYPE : 2UEM-EVM
TYPE : 2UEM-3M
81200 7705502UEM-CDX
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
81200 7705502UEM-2CDX 70, 90, 1202UEM-2CDX 200
BSP50 5081200 770620 BSP50 50
W720
100
L
100 350
125
TANK
H
VIEW `X' SIDE VIEW
SUCTION
DISCHARGE X
ELCB
ON
40A DP
181200700 8702UEM-3M32
2UEM-3M65
2UEM-3M50
2UEM-3M40
870 18
870
870
18
18
MODELDIMENSION
mmmmL
mmH TANK
LITREW
MANIFOLD (mm)SUCTION DISCHARGE
MANIFOLD (mm)PIPE
CONNECTION
65 50
6580
80 65
100 80
BSP
BSP
BSP
BSP
1200
1200
1200
700
700
700
125
L
500100 100820
W
XH
VIEW `X' SIDE VIEW
DISCHARGE
SUCTION
YR B
ELCB
40A 4P
81200 7707002UEM-MATRIX 3MODEL
DIMENSIONmmmm
LmmH TANK
LITREW
MANIFOLD (mm)SUCTION
MANIFOLD (mm)DISCHARGE PIPE
CONNECTIONBSP50 50
2UEM-MATRIX 5 700 5050770 82UEM-MATRIX 10 700 5050770 82UEM-MATRIX 18 700 5050770 8
120012001200
BSPBSPBSP
TANK
100
L
100500
125
W720
H
SIDE VIEW
SUCTION
DISCHARGE
X
VIEW `X'
40A DP
ON
ELCB
MODELW TANKHLDIMENSION
mm mm mm LITRE2UEM-EVM 3 910 1200 600 8/242UEM-EVM 5 910 8/246002UEM-EVM 10 980 600 18/242UEM-EVM 18 18/241070 7102UEM-EVM 32 1140 850 242UEM-EVM 45 1270 850 242UEM-EVM 64 8501270 24
MANIFOLD (mm)MANIFOLD (mm)SUCTION DISCHARGE
CONNECTIONPIPE
BSPBSPBSP
FLANGEFLANGEFLANGEFLANGE
50 5065 65
50 50
80 80100 100100 100150 150
120012001200120012001200
X
TANK
L W
TANK
125
H
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
EMERGENCYFAULTSTOPRUN
Variable Frequency Drive
ENTERMODERUN
STOP
SUCTION DISCHARGE
`X' VIEW ELEVATION VIEW
40A 4P
ELCB
BR Y
DIMENSION DIMENSION
• Municipal water supply.• Irrigation.• General pressure boosting application.
VFD-4000 SeriesController
• Constant Pressure ‘LCD’ Screen/‘LED’ Display PID controller with integrally built-in VFD is capable of adjusting water pressure automatically to meet actual demand. At all time.• Energy saving The use of inverter makes energy saving possible.• Compact design Space saving and light weight, permitting easy installation.• No water surge Prevent water hammering as the speed is adjusted by varying RPM due to the use of inverter.• Simple to use User-friendly controller unit that accepts minimum setting data for optional operation.
SystemEBARA
SystemEBARASystemEBARA
VFD-4500 SeriesController
EBARA Pumps Malaysia Sdn Bhd6, Jalan TP3, UEP Subang Jaya Industrial Park,47620 Subang Jaya, Selangor, Malaysia.Tel : 03-8023 6622 Fax : 03-8023 9355Email : [email protected] Website : www.ebara.com.my
EPM UE-MINI 0118
Authorised dealer: