Eaton Internormen Mobile Oil Service Units-UMFC-41 UMFC-81

download Eaton Internormen Mobile Oil Service Units-UMFC-41 UMFC-81

of 2

Transcript of Eaton Internormen Mobile Oil Service Units-UMFC-41 UMFC-81

  • 8/3/2019 Eaton Internormen Mobile Oil Service Units-UMFC-41 UMFC-81

    1/2

    Mobile Oil Service Unit

    Internormen Product Line UMFC 41 / UMFC

    The UMFC is a mobile off-linefilter unit with a fluid-controlfunction that simplifies off-linefiltration and reservoir filling.

    It is equipped with either theinnovative Interpor Fleece (VG)or well-proven Watersorp (WVG)filter element.

    The UMFC provides accurateand timely information aboutthe prevailing condition of afluid between the pump andfilter unit. This data includescontinuous measurement ofcontamination classes(according to ISO 4406:99) andthe percentage of watersaturation in the oil.

    Data is easy to read on the

    monitor and easily transfers toa standard PC using a RS-232serial interface.

    The UMFCs design permitsprogramming of desiredcontamination classes or watersaturation levels. It can operate

    in three different operatingmodes and will automaticallyshut off when it reachescontamination level, watersaturation percentage, or boththresholds. A fourth, manualstop mode is also available.

    The unit has temperaturecontrol functions as well. Thesensor of the CCT 01 particlecounter set switches to off forits protection if the oiltemperature rises above 122 F(50 C). At oil temperaturesabove 158 F (70 C), an

    automated shutoff of thesystem occurs to avoid widerdamage. The LCD monitordisplays system conditionsusing both lights and text.

    MODE1-ManualStopManually stops the unitsmotor using the motorswitch (Possible in all

    modes) MODE2-Auto-stop

    ContaminationClassesAutomatically stops theunits motor when all of thecontamination classes arebelow the programmedvalues

    MODE3-Auto-stopWatSaturationAutomaticallystops the units motor whthe water saturation

    percentage is below theprogrammed values

    MODE4-Auto-stopWatSaturationandContaminationClassesAutomatically stops theunits motor when all of tcontamination classes anthe water saturationpercentages are below thprogrammed values

    Mobile Off-line Service Unit with

    the Particle Counter CCT 01-Set

    and Water Sensor WSPS 05

  • 8/3/2019 Eaton Internormen Mobile Oil Service Units-UMFC-41 UMFC-81

    2/2

    For more information, please e-mail us [email protected]

    Visit us online ateaton.com/ltrationfora complete list of Eatons ltration products

    2012 Eaton Corporation. All Rights Reserved.All trademarks and registered trademarks are the property of their respective owners.

    Europe/Africa/Middle East

    Friedensstrae 41D-68804 Altlussheim, Germany

    Voice: +49-6205-2094-0

    Auf der Heide 253947 Nettersheim, Germany

    Voice: +49-2486-809-0

    An den Nahewiesen 2455450 Langenlonsheim, Germany

    Voice: +49 6704 204-0

    Brazil

    Av. Julia Gaioli, 474 Bonsucesso07251-500 Guarulhos, Brazil

    Voice: +55 (11) 2465-8822

    North America HQ

    70 Wood Ave., South, 2nd FloorIselin, NJ 08830

    Toll Free: (800) 656-3344(North America Only)Voice: (732) 767-4200

    China

    No. 3, Lane 280, Linhong RoadChangning District, 200335Shanghai, P.R. China

    Voice: +86-21-5200-0099

    Singapore

    4 Loyang Lane #04-01/02Singapore 508914

    Voice: +65-6825-1668

    All information and recommendations appearing in this brochure concerning the use of productsdescribed herein are based on tests believed to be reliable. However, it is the users responsibility todetermine the suitability for his own use of such products. Since the actual use by others is beyondour control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or theresults to be obtained. Eaton assumes no liability arising out of the use by others of such products. Noris the information herein to be construed as absolutely complete, since additional information may benecessary or desirable when particular or exceptional conditions or circumstances exist or because ofapplicable laws or government regulations.

    EFINMOS-4-6-12

    High-valueMeasuringTechnique

    Specifically developed forcontinuous monitoring, theCCT 01 - Set detects particles> 4 m(c), > 6 m(c), and >14 m(c) and classifies themaccording to ISO 4406:99. TheWSPS 05 sensor analyzes

    water saturation levels andoffers a reliable measurementof free water in the fluid. TheUMFCs control unit tracks oiltemperature and if necessary,prevents overheating of theunit by switching it offautomatically.

    EconomicEfciency

    Investing in an EatonInternormen system quickly

    pays for itself by providing youwith extended serviceintervals and higher machineor system availability.

    Easy andComfortableHandling

    Easily change the UFMCsfilter element by rotating thehandle counter-clockwise andlifting off the tube cover, notools necessary.

    Quality in DetailDepending on the applicationin the field and specificcustomer needs, the UMFC41/81 unit is available witheither the Interpor Fleece orthe Watersorp filter element.Each filter assures highseparation rates andexceptional dirt holdingcapacity. In turn, contaminationclasses are accurately definedand the most favorable serviceranges for your requirementsare controlled.

    UMFC 41

    Single Phase AC MotorTechnical Data

    Flow rate: 11.3 gal/min (42.8 l/min)

    Operating pressure: 87 psi (6 bar) maximum

    Viscosity: 46 to 1840 SUSPower supply: 110 V, 60 Hz (1 phase)

    Max. oil temperature: 32 to 158 F (0 to 70 C), Particle

    measuring possible up to 122 F (50 C)

    UMFC 81

    Three Phase AC Motor/PoleChangingTechnical Data

    Flow rate: 11.3 gal/min (42.8 l/min) 22.5 gal/min (85.2 l/min).

    Operating pressure: 145 psi (10 bar) maximum 145 psi (10 bar) maximum

    Viscosity: 46 to 3680 SUS 46 to 1840 SUSPower supply: 460 V, 60 Hz (3 phase) 460 V, 60 Hz (3 phase)

    Max. oil temperature: 32 to 158 F (0 to 70C) 32 to 158 F (0 to 70C)

    Particle measuring possible up to 122 F (50 C)

    (

    (