EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24...

31
EASY Touch Panel Operating instructions

Transcript of EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24...

Page 1: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

EASY Touch Panel

Operating instructions

Page 2: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

2

Contents

Description....................................................................................... 4Purpose.and.application. 4Function. 4Design. 4

Installation........................................................................................ 5Safety.instructions. 5Mounting.notes. 5Procedure. 6Connection.diagram.(example). 8

Basic.settings................................................................................... 9DIP.switches. 9Operating.modes. 9Master/slave.operation. 9

Configuration.................................................................................. 10Procedure. 10Setup.screen. 10Inserting,.removing.and.moving.operating.elements. 11Defining.label.languages. 13Labelling.the.operating.elements. 14Configuring.the.operating.element.functions. 15Setting.the.colour.of.the.operating.LED. 19Troubleshooting. 20

Operation....................................................................................... 21Principle. 21Calling.up/saving.a.light.scene. 21Starting.and.stopping.a.sequence. 21Switching.luminaires/relays. 22Dimming.luminaires. 22Controlling.the.blind/screen. 22Changing.the.light.colour.or.colour.temperature. 22

Service.functions............................................................................ 23Service.screen. 23Querying.the.firmware.version.and.DIP.switch.setting. 24Updating.the.firmware. 25Calibrating.touch.detection. 25Resetting.the.configuration.to.the.default.settings. 25Saving.the.configuration.on.an.SD.card/loading.from.an.SD.card. 26Deactivating.the.integrated.DALI.EASY.control.unit. 27Resetting.the.configurations.of.all.control.units.to.the.default.settings. 28Resetting.the.EBT. 28

Page 3: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

3

Appendix........................................................................................ 29Technical.data. 29Dimensions. 30Compatibility. 30

Page 4: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

4 XII.2010

EASY.Touch.PanelDescription

DescriptionPurpose and application

The.EASY.Touch.Panel.is.used.to.directly.control.4.light.groups.(expandable.to.16).and.to.retrieve.as.many.as.64.light.scenes..Integrated.switch.contacts.can.be.used.to.switch.4.non-dimmable.loads.or.operate.two.blinds/screens..RGB.elements.or.lamps.with.changeable.colour.temperatures.can.be.controlled.statically.and.dynamically..Integrating.the.DALI.EASY.makes.the.Touch.Panel.a.full.control.unit.used.to.control.up.to.4.light.groups.without.the.need.for.additional.components.On.the.Touch.Panel,.the.operating.elements.can.be.arranged.as.required.and.dis-played.in.multiple.languages.on.up.to.three.screen.pages.

FunctionWhen.the.user.touches.the.operating.elements,.the.Touch.Panel.evaluates.and.converts.the.signals.to.digital.control.commands..The.commands.are.transmitted.via.a.control.line.to.the.respective.electronic.control.gear.units.

DesignThe.touch.panel.consists.of.the.following.components:•. Magnetically.fixed,.removable.front.frame•. Electronic.box.with.backlit.LCD.and.touch-sensitive.surface.(A)•. SD.card.slot.(B)•. Operating.LED.(C)•. EASY.bus.socket.(D).for.programming.via.PC•. DIP.switches.(E).behind.panel•. Connector.on.the.right.side:

.– EASY.bus•. Rear.connectors:

.– Power.supply

.– DALI.output

.– EASY.bus

.– Relays

EDCBA

Page 5: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

5

EASY.Touch.Panel

XII.2010

Installation

InstallationSafety instructions

The.touch.panel.must.be.installed.and.put.into.operation.by.a.qualified.electrician.only..The.applicable.safety.regulations.and.accident.prevention.regulations.must.be.observed.

WARNING!

Exposed,.live.cables.

Danger.of.electric.shock!•. Work.on.the.Touch.Panel.only.when.it.is.de-energised.

CAUTION!

Incorrect.mounting.of.the.Touch.Panel.and.other.devices.can.result.in.their.destruc-tion!

•. The.EASY.Touch.Panel.can.only.be.used.to.control.electronic.control.gear.with.DALI.interfaces.or.components.with.an.EASY.interface.

•. Do.not.operate.other.control.units.on.the.DALI.control.lines.

•. When.connecting,.make.sure.that.the.insulation.between.the.network,.DALI,.EASY.and.relay.connection.lines.is.sufficient.

•. Adequately.insulate.sockets.and.wires.that.are.not.required.

•. The.EASY.control.unit.is.specifically.designed.for.the.installation.of.flush.device.boxes;.stand-alone.installation.is.not.permissible.

Mounting notes•. The.Touch.Panel.can.be.installed.in.light.weight.construction/hollow.walls.or.solid.walls..Suitable.flush.device.boxes.can.be.ordered.separately.from.Osram:.– Light.weight.construction/hollow.walls:.“Hollow.box”.type,.EAN.4008321552532.(F).– Solid.wall.construction:.“Concrete.box”.type,.EAN.4008321552556.(G)

•. Ensure.that.the.flush.device.box.is.precisely.aligned.both.horizontally.and.vertically.•. Do.not.mount.the.Touch.Panel.on.uneven.surfaces..It.is.imperative.to.avoid.me-chanical.pressure.and.bending.forces.on.the.Touch.Panel.

GF

EAN: 4008321552556EAN: 4008321552532

Page 6: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

6 XII.2010

EASY.Touch.PanelInstallation

ProcedureProceed.as.follows:

Step Activity1 Connection.lines.must.be.introduced.into.the.rear.of.the.flush.device.box.from.

above.or.below,.and.the.wires.stripped.directly.at.the.box.wall.

2 Adjust.the.length.of.the.connection.wires,.taking.into.account.the.position.of.the.connectors,.and.then.strip.approx..5.mm.of.the.required.wires.

3 CAUTION!Incorrect.mounting.of.the.Touch.Panel.and.other.devices.can.result.in.their.destruction!

•. It.is.particularly.important.to.wire.the.mains.connection.correctly.

Check.the.connection.assignment.of.the.connectors.against.the.numbering.in.the.diagram.(see."Connection.diagram").and.connect.the.stripped.wires.to.the.corresponding.plugs.

4 Plug.in.the.assigned.connectors..Adequately.insulate.unneeded.wires.and.plug-in.contacts.

5 Check.the.DIP.switches.for.the.relay.function.and,.especially.when.controlling.blinds/screens,.ensure.that.the.DIP.switches.are.in.the.correct.position,.see."Basic.settings".

6 Align.the.wires.and.slide.the.Touch.Panel.into.the.flush.device.box,.ensuring.that.you.do.not.exert.pressure.or.bending.forces.on.the.display.

7 Mount,.align.and.fasten.the.Touch.Panel.in.the.flush.device.box.using.the.provided.screws.

8 Protect.the.DIP.switches.from.being.changed.without.authorization.using.the.cover.panel.

Page 7: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

7

EASY.Touch.Panel

XII.2010

Installation

Step Activity9 Mount.the.front.frame.and.align.it.

10 Switch.on.the.mains.voltage.and.watch.the.display/operating.LED..The.oper-ating.LED.lights.up.when.the.mains.voltage.is.active.

Page 8: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

8 XII.2010

EASY.Touch.PanelInstallation

Connection diagram (example)

Relay A

Relay B

Relay C

Relay D

N 21

L 23

PE 25

DALI output

EASY bus

1 CH1 + (red)2 CH2 + (green)3 CH3 + (blue)4 CH4 + (white)5 GND -

11 + 5V12 SYNC13 IR14 GND

31

33

3541

43

4551

53

5561

63

65

M

LN

PE

~~DADA

~~DADA

~~DADA

~~DADA

Easy signal

24 V (+)CH1 (R-)CH2 (G-)CH3 (B-)CH4 (W-)GND (-)

OT EASY 60 II

+RGB

LED Modul LINEARlight Colormix

LNY-Connector

1 4

Y-ConnectorScrew

Slave

EASY Touch Panel (Master)

Slave

Easy signal

GND (-)CH4+ (W)CH3+ (B)CH2+ (G)CH1+ (R)

DALI EASY III

LN

1 2 3 4 5

ON

5 4 3 2 1

Lamp

Lamp

Lamp

Halogen lamps

DIP switch setting

DALI transformer

DALI ECG

DALI ECG

DALI ECG

Blind motor

Page 9: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

9

EASY.Touch.Panel

XII.2010

Basic.settings

Basic settingsDIP switches

The.basic.settings.of.the.Touch.Panel.are.adjusted.on.the.DIP.switches.

DIP Description ON OFF1 Locks/releases.the.setup.screen.

(shows/hides.the."Setup".button.in.the.task.bar)

Setup.screen.enabled

Setup.screen.locked

2 Operating.mode..(see.below)

Non-addressed.operation

Addressed.opera-tion

3 Master/slave.mode.of.integrated.DALI.EASY.control.unit.(see.below)

Master Slave

4 Method.of.operation.of.A/B.relays.for.controlling.blinds/screens

A/B.relays.operate.in.pairs.and.are.interlocked

A/B.relays.operate.independently

5 Method.of.operation.of.C/D.relays.for.controlling.blinds/screens

C/D.relays.oper-ate.in.pairs.and.are.interlocked

C/D.relays.operate.independently

Operating modesThe.Touch.Panel.supports.two.different.operating.modes.• Non-addressed operation (delivered state)All.control.units.are.addressed.(“broadcast.mode”)..Individual.control.units.can.not.be.operated.separately..This.operating.mode.is.recommended.if.a.maximum.of.4.channels/light.groups.are.to.be.controlled.

• Addressed operationUp.to.4.control.units.can.be.independently.addressed..Up.to.4.different.lighting.zones.can.be.controlled.(e.g.,.the.combination.of.coloured.effect.lighting.and.normal.room.lighting.or.up.to.16.channels/light.groups)..To.use.this.mode,.the.addresses.1..4.must.be.previously.assigned.to.the.corresponding.control.units.using.the.EASY.PC.software.

Master/slave operationThe.integrated.DALI.EASY.control.unit.can.be.operated.as.a.master.or.slave.

Note:..When.multiple.EASY.control.units.are.installed,.only.one.control.unit.can.be.config-ured.as.the.master.

The.integrated.DALI.EASY.control.unit.can.be.deactivated,.see.“Service.functions”.

Page 10: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

10 XII.2010

EASY.Touch.PanelConfiguration

ConfigurationProcedure

Proceed.as.follows.to.configure.the.Touch.Panel:

Step Activity1 Insert,.remove.and.move.operating.elements.

2 Define.label.languages.

3 Label.operating.elements.

4 Configure.the.operating.element.functions.

5 Set.the.colour.of.the.operating.LED.

The.individual.steps.are.more.closely.described.in.the.following.sections.The.configuration.can.then.be.stored.on.an.SD.card,.see.“Service.functions”.

Setup screenThe.Touch.Panel.is.configured.on.the.Setup.screen.Proceed.as.follows.to.open.and.close.the.Setup.screen:

Step Activity1 Touch.the."Setup".button.

Note:..The."Setup".button.is.only.displayed.when.DIP.switch.1.is.set.to."ON";.otherwise,.the.Setup.screen.is.locked.for.users.

The.Setup.screen.appears:

2 Touch.the.required.button,.see.the.next.section.

Page 11: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

11

EASY.Touch.Panel

XII.2010

Configuration

Step Activity3 Touch.the."Setup".button.again.to.leave.the.Setup.screen.

Inserting, removing and moving operating elementsProceed.as.follows:

Step Activity1 Touch.the."Operating.elements".button.

The.top.half.of.the.first.operating.screen.appears,.as.well.as.a.grey.ele-ment.bar.and.additional.symbols.on.the.task.bar:

Operating screen

Element bar

Task bar

Page 12: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

12 XII.2010

EASY.Touch.PanelConfiguration

Inserting operating elements

Step Activity2 If.necessary,.touch.the.following.buttons.on.the.task.bar:

....

Change.between.the.three.operating.screens.

....

Change.to.the.bottom/top.half.of.the.selected.ope-rating.screen.

3 Touch.the.desired.operating.element.type.on.the.element.bar.

The.selected.operating.element.type.is.highlighted.

The.following.operating.element.types.are.available:

•. Scene:.call.up/save.light.scene

•. Sequence:.start.and.stop.sequences

•. Switch:.switch.luminaires/relays

•. Dim:.dim/switch.luminaires.or.control.blinds/screens

•. Vary:.change.light.colour/colour.temperature.or.brightness.of.luminaires

An.exact.description.of.the.functions.can.be.found.in.the.following.sections:."Configuring.the.operating.element.functions".and."Operation".

4 Touch.a.vacant.area.(light.grey.rectangle).on.an.operating.screen..The.operating.element.is.inserted.there.

Removing/moving operating elements (optional)

Step Activity5 If.necessary,.touch.the.following.buttons.on.the.task.bar:

....

Change.between.the.three.operating.screens.

....

Change.to.the.bottom/top.half.of.the.selected.ope-rating.screen.

6 Touch.the.desired.operating.element..The.selected.operating.element.is.highlighted.

7 Touch.the."Cut".button.on.the.task.bar.

The.operating.element.is.removed.and.a.light.grey.rectangle.appears.instead.

Page 13: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

13

EASY.Touch.Panel

XII.2010

Configuration

Step Activity8 If.required,.insert.the.removed.operating.element.at.a.different.location.

("move").

To.do.this,.touch.a.vacant.area.(light.grey.rectangle).on.an.operating.screen.and.then.on.the."Insert".button.on.the.task.bar.

Note:..The.label.and.function.of.the.moved.operating.element.are.retained.

Back to the Setup screen

Step Activity9 When.all.inserted.operating.elements.have.been.inserted,.touch.the.

"Setup".button.to.return.to.the.Setup.screen.

Defining label languagesProceed.as.follows:

Step Activity1 Touch.the."Languages".button.

A.screen.appears.showing.German,.English,.French,.Spanish,.Italian.and.three.other.user-defined.languages.

2 Touch.the.respective.buttons.to.activate/deactivate.individual.languages.

•. Light.grey.=.activated

•. Dark.grey.=.deactivated

Deactivated.colours.will.not.be.available.to.the.user.later.on.as.a.label.lan-guage.

Only.English.is.activated.when.the.equipment.is.delivered.

3 Touch.the."Setup".button.to.return.to.the.Setup.screen.

.

Page 14: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

14 XII.2010

EASY.Touch.PanelConfiguration

Labelling the operating elementsAll.operating.elements.can.be.labelled.in.the.defined.labelling.languages.Proceed.as.follows:

Step Activity1 Touch.the."Label".button.

The.top.half.of.the.first.operating.screen.and.a.list.of.the.available.lan-guages.appear.

2 Touch.the.desired.language.

3 If.necessary,.touch.the.following.buttons.on.the.task.bar:

....

Change.between.the.three.operating.screens.

....

Change.to.the.bottom/top.half.of.the.selected.ope-rating.screen.

4 Touch.the.desired.operating.element.

A.keyboard.appears.

5 Enter.the.desired.label.by.touching.the.keyboard.buttons..A.preview.of.the.operating.element.is.displayed.above.the.keyboard.

6 Touch.the."Cancel".or."Ok".button.on.the.task.bar.to.discard.the.label.or.save.it.

....

The.keyboard.is.hidden.again.

Page 15: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

15

EASY.Touch.Panel

XII.2010

Configuration

Step Activity7 Label.additional.operating.elements.if.necessary.or.touch.the."Setup".but-

ton.to.return.to.the.Setup.screen.

Configuring the operating element functions

Note:..The.operating.mode.selected.for.the.Touch.Panel.(addressed/non-addressed.opera-tion).has.an.influence.on.the.possible.configuration.of.an.operating.element,.see."Basic.settings".

Operating element types

The.basic.function.is.linked.to.the.operating.element.type..The.following.operating.ele-ment.types.are.available:

Operating element type

Function

Scene Call.up/save.light.scene

Sequence Start.and.stop.sequences

Switch.on Switching.luminaires/relays

Dim Dim/switch.luminaires.or.control.blinds/screens

Vary Change.light.colour/colour.temperature.or.brightness.of.lumi-naires

The.exact.configuration.of.an.operating.element.within.the.selected.function.is.de-scribed.in.the.following.sections.

Page 16: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

16 XII.2010

EASY.Touch.PanelConfiguration

General procedure

Proceed.as.follows:

Step Activity1 Touch.the."Function".button.

The.first.operating.screen.appears.

2 If.necessary,.touch.the.following.buttons.on.the.task.bar:

....

Change.between.the.three.operating.screens.

3 Touch.the.desired.operating.element.

Depending.on.the.selected.operating.element,.a.special.configuration.screen.appears.containing.all.function.settings.selectable.for.this.operating.element.type.

The.existing.setting.is.highlighted.

The.task.bar.shows.the.type.(e.g.,.Scene.function).and.label.(e.g..Light.Scene.1).of.the.selected.operating.element.

4 Select.the.desired.function.by.touching.the.available.buttons..See.the.fol-lowing.sections.

Note:..If.the.Touch.Panel.is.configured.for.the.addressed.operation.by.DIP.switch.2,.the.respective.function.can.be.sent.addressed.to.individual.control.units..Otherwise,.all.connected.EASY.control.units.will.react.

5 Touch.the."Cancel".or."Ok".button.on.the.task.bar.to.discard.the.configura-tion.or.save.it.

....

Page 17: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

17

EASY.Touch.Panel

XII.2010

Configuration

Configuring an operating element of the “Scene” type

The.“Scene”.operating.element.type.can.be.used.to.call.up.and.save.light.scenes.

Proceed.as.follows:

Step Activity1 Touch.button(s)."Adr..1".to."Adr..4".or."All".to.select.the.addresses.of.the.

control.units.to.be.controlled.(addressed.operation.only).

2 Touch.one.of.the.buttons."A",."B",."C".or."D".to.select.the.storage/sequence.range.of.the.light.scene.

3 Touch.one.of.the.buttons."1".to."16".to.select.the.scene.number.

4 Touch.the."Enable.Storage".button.if.necessary.

•. Light.grey.=.Storage/changing.of.the.light.scene.by.applying.extended.pressure.to.the.operating.element.is.enabled.

•. Dark.grey.=.Storage/changing.of.the.light.scene.by.applying.extended.pressure.to.the.operating.element.is.disabled.

5 Touch.the."Include.Relay".button.if.necessary.

•. Light.grey.=.The.relay.setting.is.taken.into.account.when.the.scene.is.stored.(prerequisite:.scene.storage.enabled).and.restored.when.the.scene.is.called.up..

•. Dark.grey.=.The.relay.setting.is.not.affected.when.the.scene.is.called.up.

Page 18: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

18 XII.2010

EASY.Touch.PanelConfiguration

Configuring an operating element of the “Sequence” type

Dynamic.sequences.can.be.started.and.stopped.using.the.“Sequence”.operating.ele-ment.type.Proceed.as.follows:

Step Activity1 Touch.button(s)."Adr..1".to."Adr..4".or."All".to.select.the.addresses.of.the.

control.units.to.be.controlled.(addressed.operation.only).

2 Touch.the."Play".or."Stop".button:

•. Play:.start.sequence.

•. Stop:.stop.sequence.

3 Only.if."Play".is.selected:

Touch.one.of.the.buttons."A",."B",."C".or."D".to.select.the.corresponding.sequence.

Configuring an operating element of the “Switch” type

The.“Switch”.operating.element.type.can.be.used.to.switch.luminaires.and.the.inte-grated.relays.Proceed.as.follows:

Step Activity1 Touch.button(s)."Adr..1".to."Adr..4".or."All".to.select.the.addresses.of.the.

control.units.to.be.controlled.(addressed.operation.only).

2 Touch.the.desired.channel.number(s).

3 If.necessary,.touch.the.“Relay.A..D”.buttons.to.switch.the.corresponding.relays.

Precondition:.DIP.switches.4.and.5.are.configured.accordingly,.see.„Basic.settings“.

Configuring an operating element of the “Dim” type

The.“Dim”.operating.element.type.can.be.used.to.dim.and.switch.luminaires..In.addi-tion,.blinds.and.screens.can.be.controlled.Proceed.as.follows:

Step Activity1 Touch.button(s)."Adr..1".to."Adr..4".or."All".to.select.the.addresses.of.the.

control.units.to.be.controlled.(addressed.operation.only).

2 Touch.the.desired.channel.number(s).

3 If.necessary,.touch.the."Central.Dimming".button.if.the.lighting.system.is.to.be.dimmed.or.switched.centrally.

Page 19: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

19

EASY.Touch.Panel

XII.2010

Configuration

Step Activity4 If.necessary,.touch.the."Blinds.1".(relay.A+B).or."Blinds.2".(relay.C+D).but-

tons.to.activate.the.blind/screen.operation.for.the.corresponding.relays.

•. Light.grey.=.blind/screen.operation.activated

•. Dark.grey.=.blind/screen.operation.deactivated

Precondition:.DIP.switches.4.and.5.are.configured.accordingly,.see."Basic.settings".

Configuring an operating element of the “Vary” type

The.“Vary”.operating.element.type.can.be.used.to.adjust.the.lighting.colour.(RGB.mode).or.colour.temperature.(tuneable.white.operation).or.the.brightness.of.the.light-ing.

Note:.To.change.the.lighting.colour.(RGB.mode),.the.red.lighting.colour.must.be.connected.to.channel.1,.green.to.channel.2.and.blue.to.channel.3.of.the.corre-sponding.control.unit.

To.change.the.colour.temperature.(tuneable.white.operation),.the.warm.white.light-ing.colour.must.be.connected.to.channel.1.and.the.cold.white.lighting.colour.must.be.connected.to.channel.3.of.the.corresponding.control.unit.

See.also.the.instructions.of.the.respective.control.unit.

Proceed.as.follows:

Step Activity1 Touch.button(s)."Adr..1".to."Adr..4".or."All".to.select.the.addresses.of.the.

control.units.to.be.controlled.(addressed.operation.only).

2 Touch.one.of.the.following.buttons:

•. "Color":.light.colour.(RGB.mode).

•. "Color.Temp.":.colour.temperature.(tuneable.white.operation)

•. "Color.Brightness":.brightness.(RGB.mode)

•. "Color.Temp..Brightness":.brightness.(tuneable.white.operation)

Setting the colour of the operating LEDThe.operating.LED.of.the.front.frame.can.be.set.to.one.of.12.different.colours..Proceed.as.follows:

Step Activity1 Touch.the."LED.Colour".button.

2 Touch.the.arrow.buttons.of.the."Bar.Color".button.to.change.the.colour.

Page 20: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

20 XII.2010

EASY.Touch.PanelConfiguration

Troubleshooting

Fault Possible cause EliminationDisplay.remains.dark. No.power.supply. Check.whether.the.operating.

LED.in.the.front.frame.is.lit.

If.necessary,.create.the.power.supply.

Operating.elements.can-not.be.operated.reliably.

Touch.detection.is.not.operating.correctly.

Recalibrate.the.Touch.Panel.via.the.Service.screen.

Connected.control.units.do.not.react.to.Touch.Panel.operation.even.in.case.of.central.com-mands.

There.is.no.master.or.there.are.multiple.mas-ters.in.the.system.

De-energise.the.system.and.check.the.master/slave.configu-ration.of.all.control.units.

Ensure.that.only.one.master.exists.

The.firmware.of.the.control.unit.is.not.cur-rent.

(Only.firmware.ver-sions.5.0.or.higher.are.compatible)

Check.the.firmware.version.with.the.EASY.PC.software.and.per-form.a.firmware.update.using.the.EASY.Updater.if.necessary.

Connected.control.units.can.be.controlled.centrally.but.not.individually.

Addresses.(1...4).were.not.assigned.in.advance.for.the.individ-ual.control.units.via.the.EASY.PC.software.

Check.the.addresses.of.the.control.units.via.the.EASY.PC.software..Ensure.that.the.right.address.is.selected.for.assigning.the.func-tion.to.the.corresponding.screen.elements.

Relay.contacts.for.switch-ing.non-dimmable.con-sumers.do.not.remain.closed.permanently.

The.corresponding.relays.are.configured.for.blind.operation.

Change.the.DIP.switch.setting.

Changing.of.the.colour.temperature.via.the."Color.Temp.".operating.ele-ment.does.not.operate.as.expected.

Illuminant.is.incorrectly.connected.

Connect.warm.white.illuminant.to.channel.1,.cold.white.illumi-nant.to.channel.3.of.the.corre-sponding.control.unit.

Changing.of.the.light.col-our.via.the."Color".oper-ating.element.does.not.operate.as.expected.

Illuminant.is.incorrectly.connected.

Connect.the.red.illuminant.to.channel.1,.green.illuminant.to.channel.2.and.blue.illuminant.to.channel.3.of.the.corresponding.control.unit.

Page 21: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

21

EASY.Touch.Panel

XII.2010

Operation

OperationPrinciple

The.unit.is.operated.by.briefly.touching.operating.elements.(e.g..to.call.up.a.light.scene).or.by.touching.them.for.an.extended.period.(e.g..dimming)..The.operating.ele-ment.is.highlighted.and.the.activation.is.confirmed.by.clicking.The.function.depends.on.the.type.and.configuration.of.the.operating.element,.see.“Configuration”.The.operating.elements.are.distributed.on.no.more.than.three.screen.pages,.which.can.be.opened.using.the.arrow.buttons.on.the.task.bar.

Task bar

Screen page

Calling up/saving a light scene

.•. Call.up.a.light.scene:.briefly.touch.the.operating.element.

•. Save.a.light.scene:.press.the.operating.element.for.an.extended.period.until.the.lighting.flashes.to.confirm.(precondition:.scene.storage.has.been.enabled).

Note:.The.position.of.the.blinds/screens,.which.are.controlled.via.integrated.relays,.can.only.be.restored.by.calling.up.light.scenes.directly.via.the.Touch.Panel..

If.the.position.of.the.blinds.or.screens.should.be.stored,.the.respective.relay.must.be.closed.when.the.setting.is.stored,.i.e..the.light.scene.must.be.stored.within.90.seconds.after.the.extended.pressure.on.the.blind.operating.element.ends.

Starting and stopping a sequence

.•. Start.a.sequence:.briefly.touch.the."Play".operating.element.

•. Stop.a.sequence:.briefly.touch.the."Stop".operating.element.

Page 22: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

22 XII.2010

EASY.Touch.PanelOperation

Switching luminaires/relays

.

•. Switch.on:.briefly.touch.the."I".symbol.

•. Switch.off:.briefly.touch.the."0".symbol.

Dimming luminaires

.

•. Increase.brightness:.press.upper.arrow.symbol.for.an.extended.period.

•. Switch.to.100%:.briefly.touch.the.upper.arrow.symbol.

•. Reduce.brightness:.press.lower.arrow.symbol.for.an.extended.period.

•. Switch.off:.briefly.press.the.lower.arrow.symbol.

Controlling the blind/screen

.

•. Move.up/down:.press.the.upper.or.lower.arrow.button.for.an.extended.period..If.the.arrow.symbol.is.pressed.for.longer.than.3.s,.the.relay.remains.closed.for.90.s.and.the.blind/screen.automatically.moves.to.the.limit.position.

•. Stop:.briefly.press.the.arrow.symbol.for.the.opposite.direction.

•. Open/close.the.blind.slats:.briefly.touch.the.upper.or.lower.arrow.symbol.

Changing the light colour or colour temperature

.

•. Change.the.light.colour.(RGB.mode):.press.the."+".or."-".symbol.for.an.extended.period.until.the.required.colour.is.reached.

•. Change.the.colour.temperature.(tuneable.white.mode):.Press."+".symbol.for.an.extended.period.to.reduce.the.colour.temperature.(=.warmer.light)..Press.the."-".symbol.for.an.extended.period.to.increase.the.colour.temperature.(=.colder.light).

Page 23: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

23

EASY.Touch.Panel

XII.2010

Service.functions

Service functionsService screen

The.service.functions.are.executed.on.the.Service.screen.Proceed.as.follows.to.open.and.close.the.Service.screen:

Step Activity1 Touch.the."Setup".button.

Note:..The."Setup".button.is.only.displayed.when.DIP.switch.1.is.set.to."ON";.otherwise,.the.Setup.screen.is.locked.for.users.

The.Setup.screen.appears:

Page 24: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

24 XII.2010

EASY.Touch.PanelService.functions

Step Activity2 Touch.the."SERVICE".button.

The.Service.screen.appears:

3 Touch.the.required.button,.see.the.next.section.

4 Touch.the."Setup".button.to.leave.the.Service.screen.again.

5 Touch.the."Setup".button.again.to.leave.the.Setup.screen.

Querying the firmware version and DIP switch settingProceed.as.follows:

Step Activity1 Touch.the."Info".button.

The.firmware.version.and.DIP.switch.setting.are.displayed.

Page 25: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

25

EASY.Touch.Panel

XII.2010

Service.functions

Updating the firmwareProceed.as.follows:

Step Activity1 Save.the.current.configuration.of.the.Touch.Panel.on.an.SD.card,.see."Sav-

ing.the.configuration.on.an.SD.card/loading.from.an.SD.card".

2 Download.the.current.firmware.(http://www.osram.com/lms).and.save.it.on.an.SD.card.

3 Insert.the.SD.card.with.the.current.firmware.into.the.SD.card.slot.of.the.Touch.Panel.

4 Touch.the."Update.Firmware".button.

The.firmware.versions.of.the.Touch.Panel.and.on.the.SD.card.are.displayed..If.the.two.versions.differ,.the.firmware.of.the.Touch.Panel.is.updated.auto-matically.

5 Take.the.SD.card.back.out.of.the.slot.

Calibrating touch detectionIt.may.be.necessary.to.calibrate.touch.detection.if.detection.becomes.imprecise.due.to.temperature.fluctuations,.for.example.Proceed.as.follows:

Step Activity1 Touch.the."Calibrate.Touch.Screen".button.

2 Touch.the.displayed.screen.points.one.after.the.other.as.precisely.as.pos-sible.

Touch.detection.is.recalibrated.when.the.procedure.is.completed.

Resetting the configuration to the default settingsThe.configuration.of.the.Touch.Panel.can.be.reset.to.the.default.settings..This.proce-dure.deletes.the.current.configuration.of.the.operating.elements.(see.“Configuration”).Proceed.as.follows:

Step Activity1 If.necessary,.save.the.current.configuration.of.the.Touch.Panel.on.an.SD.

card,.see."Saving.the.configuration.on.an.SD.card/loading.from.an.SD.card".

Page 26: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

26 XII.2010

EASY.Touch.PanelService.functions

Step Activity2 Touch.the."Reset.Button.Config".button.

The.Touch.Panel.configuration.is.reset.

Saving the configuration on an SD card/loading from an SD cardAn.SD.card.can.be.used.to.save.and.reload.up.to.9.different.configurations.(see.“Con-figuration”)..This.can.be.used.to.copy.configurations.from.one.Touch.Panel.to.another.

Note:..All.settings.are.stored.in.the.Touch.Panel.itself,.even.in.the.event.of.lengthy.power.supply.interruptions..For.this.reason,.an.SD.card.is.not.needed.for.operation.

Saving configuration

A.configuration.can.be.saved.on.an.SD.card.under.one.of.the.fixed.file.names..(config01.tsf.….config09.tsf).

Note:..Existing.configuration.files.on.the.SD.card.with.the.same.file.name.are.overwritten.

Proceed.as.follows:

Step Activity1 Select.the.file.name.by.touching.the.arrow.symbols.

2 Touch.the."Save.Settings".button.

The.configuration.is.stored.on.the.SD.card.

Page 27: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

27

EASY.Touch.Panel

XII.2010

Service.functions

Loading a configuration

Proceed.as.follows:

Step Activity1 The.current.configuration.is.overwritten.when.a.new.configuration.is.

loaded..If.necessary,.save.the.current.Touch.Panel.configuration.on.an.SD.card,.see."Saving.the.configuration".

2 Insert.the.SD.card.containing.the.required.configuration.into.the.SD.card.slot.of.the.Touch.Panel.

3 Select.the.file.name.by.touching.the.arrow.symbols.

4 Touch.the."Load.Settings".button.

The.configuration.is.loaded..After.the.loading.procedure.is.completed,.the.Touch.Panel.automatically.changes.back.to.the.operating.screen.

5 Take.the.SD.card.back.out.of.the.slot.and.keep.it.in.a.safe.place.

Deactivating the integrated DALI EASY control unitThe.integrated.DALI.EASY.control.unit.can.be.deactivated.if.it.is.not.required.(e.g..if.only.OT.EASY.LED.operating.units.are.to.be.controlled).Proceed.as.follows:

Step Activity1 Touch.the."Control.Unit.Enable".button.

•. Dark.grey.=.control.unit.deactivated.(default.settings)

•. Light.grey.=.control.unit.activated

Page 28: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

28 XII.2010

EASY.Touch.PanelService.functions

Resetting the configurations of all control units to the default settingsYou.can.reset.the.configurations.of.all.integrated.and.connected.control.units.to.the.default.settings.Proceed.as.follows:

Step Activity1 If.necessary,.store.the.current.configurations.of.the.control.units.with.the.

EASY.PC.software.

2 Touch.the."Reset.Control.Units".button.

All.control.units.are.reset.to.the.default.settings..

Resetting the EBTThe.“Reset.EBT”.button.is.reserved.for.manufacturer.service.

Page 29: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

29

EASY.Touch.Panel

XII.2010

Appendix

AppendixTechnical data

Supply.voltage 100-240.V/50-60.HzPower.consumption,.opera-tion/stand-by

8.W./.3.W

Ambient.temperature 0…+40.°CProtection.type IP.20Maximum.load.capacity.of.DALI.outputs

(sum.of.all.channels/.asymmetrical.load.permis-sible)

64.mA.(32.DALI.devices)

Max..DALI.line.length.with.1.5.mm².line.cross.section.(sum.of.all.channels)

300.m

Max..EASY.line.length.(sum.of.all.components)

100.m

Switching.load.of.relay.out-puts.

10.A.resistive.load.or1.A.inductive.load.orfluorescent.lamps.ECG.load-..2.pcs..QTP5.2x49.GII.or.QTP5.2x54.GII.or.QTi.2x35/49/80.or

-..3.pcs..QTP5.2x14-35.GII.or.QTP5.2x24-39.GII.or.QTP5.1x54.GII.or.QTP5.1x80.GII.or

-..4.pcs..QT.Fit8.2x36.or.QT.Fit8.2x58.or.QT.Fit8.3/4x18.or.QT.Fit8.2x70.or

-..5.pcs..QTP5.1x14-35.GII.or.QTP5.1x.24-39.GII.or.QTP5.1x.49.GII.or.

-..7.pcs..QT.Fit8.1x18.or.QT.Fit8.1x36.or.QT.Fit8.1x58-70.or.QT.Fit8.2x18.or.QTi.2x28/54.or..QTi.2x35/49.or

-..10.pcs..QTi.1x35/49/80.or.QTi.2x14/24/21/39.or-.15.pcs..QTi.1x28/54.or-.20.pcs..QTi.1x14/24/21/39.orHalotronic.NV.halogen.lamp.transformers-.7.pcs..HTM150.or-.10.pcs..HTM.105.or-.15.pcs..HTM.70

Screen.diagonal 5.7“Resolution 640.x.480.pixelsTouch.detection ResistiveBackground.lighting LED

Page 30: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

30 XII.2010

EASY.Touch.PanelAppendix

Dimensions

a

b c

d

a:.160.mm./.b:.220.mmc:..55.mm./.d:.51.mm

CompatibilityThe.EASY.Touch.Panel.is.compatible.with.EASY.control.units.of.firmware.version.5.0.and.higher.(the.firmware.version.of.the.control.units.can.be.determined.using.the.EASY.PC.software)..Control.units.with.firmware.version.2.0.and.higher.can.be.updated.using.the.EASY.Update.Tool.(http://www.osram.com/lms).

Page 31: EASY Touch Panel · PDF fileQuerying.the.firmware.version.and.DIP.switch.setting. 24 Updating.the.firmware. 25 Calibrating.touch.detection. 25 ... zones.can.be.controlled.

OSRAM GmbH.Kunden.Service.Center.Customer-Service-Center.(CSC).Steinerne.Furt.62.86167.Augsburg.GermanyTel.:..+49.(0).1803.677.-.200..(kostenpflichtig./.charges.apply).Fax.:.+49.(0).1803.677.-.202www.osram.comwww.osram.de

XII.2010EASY_Touch_Panel_ba1012_EN_we1.01.indd

400832195698944008321956989