easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS...

27
3in1 LED Modules easy, effective, elegant

Transcript of easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS...

Page 1: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

3in1 LED Moduleseasy, effective, elegant

Page 2: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

3in1 LED Moduleseasy, effective, elegant

The Company reserves the right to change any product specifications without prior notification.

Page 3: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

33IN1 LED MODULES 2/

3in1 LED Modules

There are many LED modules and LED Light Engines (LLE) available

on the market, usually comprised of LED light sources, engines, and

drivers. In most cases, further components must be added to assure

their correct functionality. The first of those is a heatsink. As LED light

sources and modules with high lumen outputs are sensitive to thermal

conditions, heatsinks are an intrinsic part of the development process

for most luminaires. However, what really differentiates a luminaire is

its ability to provide a desired LIDC. With standard LED modules and

engines, the optical aspects of the luminaire design must be solved

through the addition of reflectors, refractors, or lenses.

Herein lies the key to what makes iLumTech 3in1 LED modules unique:

they are ready to use without the need for further development.

Our 3in1 LED modules combine high-performance LED light sources

with carefree thermal management and an original optical system,

making them an ideal choice for both luminaire manufacturers and

those wishing to create a bespoke lighting solution.

BUILT-IN OPTICSAll of our 3in1 LED modules include their own optical system. Each module is available with a range of light distribution curves so that there is always one to meet your specific needs.

PERFECT FOR BESPOKE LIGHTING SOLUTIONSAre you a lighting designer who wants to do something different? Our 3in1 LED modules can be installed in a wide variety of ways, allowing you to create truly bespoke solutions that do not depend on specific luminaires.

REDUCE DEVELOPMENT TIME & COSTSBecause our 3in1 LED modules combine everything needed to make your luminaire or solution work, you don't need to develop anything, unless you want to design your own luminaire housing.

CAREFREE THERMAL MANAGEMENTOur 3in1 LED modules include everything needed for excellent thermal management. As LED performance, reliability, and lifetime depend on good thermal management, we spare no effort in designing the very best heatsinks.

IDEAL FOR MANUFACTURERSDo you want a simple and cost-effective route to create your own luminaires without investment in full product development? Our 3in1 LED modules are incredibly easy to implement in any luminaire you wish to make.

READY TO USEiLumTech 3in1 LED modules are ready to use without further development as they include everything you need in one easy-to-implement unit: LED light sources, thermal management, and optics.

HIGH-PERFORMANCE LEDsWe use high-quality, high-performance LEDs in our 3in1 modules with both lower lumen outputs suitable for interior lighting as well as higher lumen outputs for industrial and exterior applications.

Page 4: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

53IN1 LED MODULES 4/

Infinitas

LEDS• Net lumen output of up to 1100 lm• UGR 21/24 (as low as UGR 16 in situ)• CCTs of 3000 K or 4000 K• CRI 83 (CRI 93 on request)• MacAdam 3

OPTICS• Hybrid optics comprising a PMMA microprismatic diffuser and metallised

reflector

THERMAL MANAGEMENT• Aluminium plate

EFFICACY• Up to 137 lm/W (excluding driver)

APPLICATION• INFINITAS' lighting parameters make it ideal for use in office, hospitality,

education, laboratory, presentation, retail, and residential lighting applications

• Easy to incorporate into general illumination and track luminaires, and modular lighting systems

• Can be installed directly in suspended ceilings, shelves, metal profiles, and furniture

• A lifetime of up to 131,500 hours means INFINITAS can maintain performance for many years

INFINITAS is a compact and ready-to-use LED module to be

incorporated into general illumination and track luminaires

as well as modular lighting systems. It is also possible to

install INFINITAS directly into suspended ceilings, shelves,

metal profiles, and furniture.

Page 5: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

73IN1 LED MODULES 6/

MECHANICAL DESIGNThe mechanical design of INFINITAS is tailored to the idea of easy installation. Whether mounting into a luminaire, a shelf, or directly into a ceiling, all you need to do is attach the module using two M4 screws.

INSTALLATION FRAMETo achieve a smooth opening, we recommend laser cutting or the use of an additional frame placed within the opening to ensure a good finish.

Mechanical design

Aluminium mounting plate that

acts as a heatsink for the module

Thermal interface material

Cover pad

FR4 PCB with flexible lumen output

according to used drive current

Two installation screws make

it easy to install the module

Metallised reflector

PMMA microprismatic diffuser

INFINITAS 4 INFINITAS 8

18.6

/o 4.5

128

57 6720

.8

18.6

20.8

/o 4.5

/o 4.5

84

Page 6: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

93IN1 LED MODULES 8/

Optical design

The INFINITAS optical system consists of a 2D- and 3D-geometric structured diffuser that modifies the light distribution of the light source, and a reflector that directs the light in the specified shape. The combination of these two optical parts enables INFINITAS to provide an LIDC and glare rating suitable for use in offices in accordance with associated standards. In fact, UGR <16 and an average illuminance of the light emitting surface of Lavg < 1500 cd/m2

is possible in situ.

Manufacturers and lighting designers can choose between and combine different types and numbers of INFINITAS units in order to achieve a desired LIDC, which can be further refined by setting of the drive current for each unit.

Electronic parameters

INFINITAS 4 – CRI 80, ta 25 °C

CCT [K]Net lumen output [lm]

Nominal current [mA]

Typical voltage [V]

Max. voltage [V]

Typical power[W]

Typical efficacy[lm/W]

3000 350 250 10.54 11.5 2.6 132.8

4000 360 250 10.54 11.5 2.6 136.6

3000 600 450 10.78 11.72 4.9 123.7

4000 620 450 10.78 11.72 4.9 127.8

INFINITAS 4 – CRI 90 (R9 50), ta 25 °C

CCT [K]Net lumen output [lm]

Nominal current [mA]

Typical voltage [V]

Max. voltage [V]

Typical power[W]

Typical efficacy[lm/W]

3000 230 250 11.2 12 2.8 82.1

4000 260 250 11.2 12 2.8 92.9

3000 400 450 11.5 12.4 5.2 77.3

4000 460 450 11.5 12.4 5.2 88.9

INFINITAS 8 – CRI 80, ta 25 °C

CCT [K]Net lumen output [lm]

Nominal current [mA]

Typical voltage [V]

Max. voltage [V]

Typical power[W]

Typical efficacy[lm/W]

3000 700 250 21.1 23 5.3 132.7

4000 720 250 21.1 23 5.3 136.5

3000 1200 450 21.55 23.43 9.7 123.7

4000 1240 450 21.55 23.43 9.7 127.9

INFINITAS 8 – CRI 90 (R9 50), ta 25 °C

CCT [K]Net lumen output [lm]

Nominal current [mA]

Typical voltage [V]

Max. voltage [V]

Typical power[W]

Typical efficacy[lm/W]

3000 460 250 22.5 24 5.6 81.8

4000 520 250 22.5 24 5.6 92.4

3000 800 450 23 24.8 10.4 77.3

4000 920 450 23 24.8 10.4 88.9

INFINITAS 4 – 3 W

INFINITAS 8 – 5 W

INFINITAS 4 – 5 W

INFINITAS 8 – 10 W

Page 7: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

113IN1 LED MODULES 10/

Thermal parameters

EXPECTED LIFETIME & RELIABILITYThe INFINITAS module is designed to operate without an additional heatsink in ambient temperatures

of up to 55 °C. The expected lifetime of the unit, when used in compliance with the defined operating

condition parameters, is 50,000 hours/L80 B20 and 70,000 hours/L70 B50.

OPERATIONAL CONDITIONSStorage ambient temperature range (ta):-30 °C to + 80 °C

Operating ambient temperature range (ta): -20 °C to + 55 °C

Drive current: max. 450 mA

INFINITAS 4 – 250 mA

ta [°C] tc ofLED [°C]

tp [°C]ta 70 °C

Typical power [W]

Lumen[lm]ta 70 °C

Lifetime [hours]

L80 B10 L80 B20 L70 B50

25 50 45 2.8 300 55,000 60,000 >70,000

30 55 50 2.8 300 55,000 60,000 >70,000

35 60 55 2.8 300 53,500 60,000 >70,000

40 65 60 2.8 300 51,000 59,500 >70,000

45 70 65 2.8 300 49,000 57,000 >70,000

50 75 70 2.8 300 47,500 55,000 >70,000

55 80 75 2.8 300 44,400 51,500 >70,000

INFINITAS 4 – 450 mA

ta [°C] tc ofLED [°C]

tp [°C] ta 70 °C

Typical power [W]

Lumen[lm]ta 70 °C

Lifetime [hours]

L80 B10 L80 B20 L70 B50

25 70 65 5.3 550 50,000 60,000 >70,000

30 75 70 5.3 550 48,500 58,000 >70,000

35 80 75 5.3 550 47,000 55,500 >70,000

40 85 80 5.3 550 44,500 51,500 >70,000

45 90 85 5.3 550 35,000 41,000 >70,000

INFINITAS 8 – 250 mA

ta [°C] tc ofLED [°C]

tp [°C]ta 70 °C

Typical power [W]

Lumen[lm]ta 70 °C

Lifetime [hours]

L80 B10 L80 B20 L70 B50

25 50 45 5.5 650 55,000 60,000 >70,000

30 55 50 5.5 650 55,000 60,000 >70,000

35 60 55 5.5 650 53,000 60,000 >70,000

40 65 60 5.5 650 51,000 59,500 >70,000

45 70 65 5.5 650 49,000 57,000 >70,000

50 75 70 5.5 650 47,500 55,000 >70,000

55 80 75 5.5 650 44,400 51,500 >70,000

INFINITAS 8 – 450 mA

ta [°C] tc ofLED [°C]

tp [°C] ta 70 °C

Typical power [W]

Lumen[lm]ta 70 °C

Lifetime [hours]

L80 B10 L80 B20 L70 B50

25 70 65 10.5 1100 50,000 60,000 >70,000

30 75 70 10.5 1100 48,500 58,000 >70,000

35 80 75 10.5 1100 47,000 55,500 >70,000

40 85 80 10.5 1100 44,500 51,500 >70,000

45 90 85 10.5 1100 35,000 41,000 >70,000

TYPICAL TEMPERATURE COEFFICIENT OF FORWARD VOLTAGE (mV / °C) ΔVf / Δtp -1.8 VALID If FOR 250-450 mA

250 mA (ta 25 °C=tp 45 °C)

Rel

ativ

e lim

inou

s flu

x (%

)

Forward current [mA]

275

250

225

200

100

175

75

150

50

125

25

0

250

600

300

650

100

450

150

500

350

700

200

550

400

Relative luminous flux vs. forward current – tp 45 °C

Rel

ativ

e lim

inou

s flu

x (%

)

Forward current [mA]

100

175

75

150

50

125

25

0

250

600

300

650

100

450

150

500

350

700

200

550

400

Relative luminous flux vs. forward current – tp 65 °C

Forw

ard

curr

ent

[mA

]

Relative forward voltage [%]

700

500

300

100

600

400

200

0

650

450

250

50

550

350

150

98 109106105102100

Forward current vs. relative forward voltage – tp 45 °C

Forw

ard

curr

ent

[mA

]

Relative forward voltage [%]

700

500

300

100

600

400

200

0

650

450

250

50

550

350

150

98 109106105102100

Forward current vs. relative forward voltage – tp 65 °C

Rel

ativ

e lu

min

ous

flux

[%]

tp [ºC]

110

105

100

95

90

85

805 55 9545 8535 7525 6515

Relative luminuos flux vs. tp, for 250 mA If

Rel

ativ

e lu

min

ous

flux

[%]

tp [ºC]

115

110

105

100

95

90

855 55 9545 8535 7525 6515

Relative luminuos flux vs. tp, for 450 mA If

450 mA (ta 25 °C=tp 65 °C)

tc POINTThe tc point is the location on the PCB where the hottest LED in found. This can be ascertained using a thermal imaging camera. Mount a type K thermocouple on the closest point to the thermal pad – cathode. Make sure that the thermocouple is fixed in direct contact with the tc point. The maximum permissible temperature at the tc point must be checked under worst-case operational conditions and in a thermally stable state.

tp POINTThe tp point refers the temperature at the tc point related to the performance of the LED. It is located on the top side of the PCB.

Page 8: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

133IN1 LED MODULES 12/

Isolines (E)Luminaire layoutOPEN OFFICE

DETAILSDimensions: 17 x 6.6 mNumber of INFINITAS: 100Number of luminaires: 20Luminaire load: 35 WLuminaire output: 3663 lm / 4000 K

ACHIEVED VALUESTotal luminous flux: 73,262 lmTotal load: 700 WMaintenance factor: 0.9Boundary zone: 0.5 m

Uniformity: u0 = 0.059 (1:17), Emin / Emax = 0.035 (1:28)Illuminance Quotient: Walls / working plane = 0.263 Ceiling / working plane = 0.283Connected load: 6.24 W/m2 = 1.00 W/m2/100 lx (area: 112.20 m2)

Example application

630 630 630

17.00 m

16.50

15.22

14.67

13.61

13.07

12.49

11.75

11.26

9.98

9.17

8.55

8.07

7.28

6.02

5.33

4.55

2.24

1.39

0.50

0.00

0.00 0.96 2.01 2.96 3.93 4.91 6.60 m

630630630

630

840

840

840 840 840

840

840 840840

840

840

840

840

840420420

420

210 210

210210

630

630630 630 630

630

630630

630 630630

630

630630630630

630630 630

840

840

17.00 m

15.07

11.82

8.56

5.30

2.05

0.00

0.00 0.83 2.48 4.13 5.77 6.60 m

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

Surface

Average illuminance [lx]Reflective factor [%]

Avg. luminance [cd/m2]Direct Indirect Total

Working plane 519 106 625 – –

Floor 284 74 357 18 20

Ceiling 0.02 176 176 70 39

Wall 1 48 33 35 50 56

Wall 2 51 109 160 50 25

Wall 3 53 116 169 50 27

Wall 4 98 119 217 50 35

Page 9: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

153IN1 LED MODULES 14/

Inspiration

Page 10: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

173IN1 LED MODULES 16/

Page 11: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

193IN1 LED MODULES 18/

Fortis

FORTIS IP66, IK08 is a powerful, highly efficient, and extra

durable 3in1 LED module designed for use in demanding

low- to high-bay industrial applications, either as individual

units or in groups. A tough design, lifetime of up to 195,000

hours, and deterioration-resistant optics enable FORTIS to

provide excellent and reliable light output for many years.

LEDS• 36 hi-power LEDs provide a net lumen output of up to 9800 lm from

each 132 cm2 module• CCTs of 3000 K, 4000 K, and 5000 K• CRI 70 or 80

OPTICS• Deterioration-resistant PMMA PLEXIGLAS® lens array with an LOR of

93 % and high light transmission for 30 years• 7 different LIDC options to suit a range of illumination, installation, and

mounting height needs – narrow, medium, wide, extra wide, extra large, opal, and clear

THERMAL MANAGEMENT• Anodised extruded aluminium heat sink

EFFICACY• Up to 161 lm/W (excluding driver)

APPLICATION• FORTIS' lighting parameters and high IP66 and IK08 rating make it

ideal for use in low- to high-bay industrial applications, linear industrial systems, stadiums, and as a mast-top luminaire

• Can be installed individually or as groups

Page 12: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

213IN1 LED MODULES 20/

ADJUSTABLE MOUNTING BRACKETA mounting bracket to be attached to a ceiling, wall, or mast. It allows for vertical and horizontal rotation of the module to achieve correct light direction.

Mechanical design

Anodised extruded aluminium heat sink

Thermal interface material

Silicon gasket

Metal core PCB with Nichia 219C

hi-power LEDs

PMMA PLEXIGLAS® lens array

that does not yellow and

guarantees a high level of light

transmission for 30 years

MOUNTING RAILSAluminium mounting rails that enable flexible configuration into groups (2x, 4x, etc.). Rails can be mounted on ceilings and walls or suspended, and are available in standard lengths of 0.6 m and 1.2 m, with other lengths on request.

SUSPENSION KITStainless steel suspension cables and associated accessories for suspension of mounting rails.

120

110

71

141

98

141

120

120

97

/o 6.5

Page 13: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

233IN1 LED MODULES 22/

Optical design

The FORTIS optical system uses a high-grade PLEXIGLAS® lens array with an LOR of 93 %. The optical material is deterioration-resistant and does not yellow over time, guaranteeing high light transmission for 30 years.

FORTIS is available in seven different LIDC variants to suit a range of illumination, installation, and mounting height specifications.

Technical parameters

CRI 70, ta 25 °C

CCT [K]Optical variant

Nominal current [mA]

Typical power [W]

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 350 35 5250 150

700 73 9050 124

3000 ME 24º 350 35 5200 149

700 73 8950 123

3000 WI 28º 350 35 5000 143

700 73 8600 118

3000 EW 48º 350 35 4850 139

700 73 8350 114

3000 EL 20/40º

350 35 5000 143

700 73 8600 118

3000 OV 110º 350 35 3900 111

700 73 6700 92

3000 CV 125º 350 35 5050 144

700 73 8700 119

4000 NA 22º 350 35 5650 161

700 73 9700 133

4000 ME 24º 350 35 5600 160

700 73 9650 132

4000 WI 28º 350 35 5350 153

700 73 9200 126

4000 EW 48º 350 35 5200 149

700 73 8950 123

4000 EL 20/40º

350 35 5400 154

700 73 9250 127

4000 OV 110º 350 35 4200 120

700 73 7200 99

4000 CV 125º 350 35 5450 156

700 73 9350 128

5000 NA 22º 350 35 5500 159

700 73 9800 134

5000 ME 24º 350 35 5500 157

700 73 9700 133

5000 WI 28º 350 35 5250 150

700 73 9250 127

5000 EW 48º 350 35 5100 146

700 73 9000 123

5000 EL 20/40º

350 35 5250 150

700 73 9300 127

5000 OV 110º 350 35 4100 117

700 73 7250 99

5000 CV 125º 350 35 5350 153

700 73 9400 129

CRI 80, ta 25 °C

CCT [K]Optical variant

Nominal current [mA]

Typical power [W]

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 350 35 4600 131

700 73 7900 108

3000 ME 24º 350 35 4550 130

700 73 7800 107

3000 WI 28º 350 35 4350 124

700 73 7500 103

3000 EW 48º 350 35 4250 121

700 73 7250 99

3000 EL 20/40º

350 35 4400 126

700 73 7500 103

3000 OV 110º 350 35 3400 97

700 73 5850 80

3000 CV 125º 350 35 4450 127

700 73 7600 104

4000 NA 22º 350 35 4850 139

700 73 8300 114

4000 ME 24º 350 35 4800 137

700 73 8250 113

4000 WI 28º 350 35 4600 131

700 73 7850 108

4000 EW 48º 350 35 4450 127

700 73 7650 105

4000 EL 20/40º

350 35 4600 131

700 73 7900 108

4000 OV 110º 350 35 3600 103

700 73 6150 84

4000 CV 125º 350 35 4650 133

700 73 7800 107

5000 NA 22º 350 35 4800 137

700 73 8500 116

5000 ME 24º 350 35 4750 136

700 73 8450 116

5000 WI 28º 350 35 4550 130

700 73 8050 110

5000 EW 48º 350 35 4450 127

700 73 7850 108

5000 EL 20/40º

350 35 4600 131

700 73 8100 111

5000 OV 110º 350 35 3550 101

700 73 6300 86

5000 CV 125º 350 35 4650 133

700 73 8200 112

Narrow (NA) 22º

Extra wide (EW) 48º

Extra large (EL) 20º x 40º

Wide (WI) 28º

Medium (ME) 24º

Clear (CV) 125ºOpal (OV) 110º

DRIVER CONNECTIONConnect using cables with a diameter of 0.2–0.75 mm2 and a thermal resistance of more than 100 °C.

Page 14: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

253IN1 LED MODULES 24/

Thermal parameters

EXPECTED LIFETIME & RELIABILITYThe FORTIS module is designed to operate in ambient

temperatures of up to 55 °C. The expected lifetime of

the unit, when used in compliance with the defined

operating conditions, is 195,000 hours/L80 B20.

OPERATIONAL CONDITIONSStorage ambient temperature range (ta): -30 to +80 °C

Operating ambient temperature range (ta): -25 to +55 °C

Drive current: max. 1050 mA

Max. tp: 100 ºC

TYPICAL TEMPERATURE COEFFICIENT OF FORWARD VOLTAGE

350 mA

Rel

ativ

e lim

inou

s flu

x (%

)

Rel

ativ

e lim

inou

s flu

x (%

)

Forward current [mA] Forward current [mA]

180

200

100

100

160

160

80

80

140

140

6060

120

120

4040

20 20

0 0

250

550

600

900

300

600

650

950

450

750

500

800

350

650

700

1050

1000200

500

550

850

400

700

Relative luminous flux vs. forward current – tp 54 °C Relative luminous flux vs. forward current – tp 80 °C

Rel

ativ

e fo

rwar

d vo

ltag

e [%

]

Rel

ativ

e fo

rwar

d vo

ltag

e [%

]

Forward current [mA] Forward current [mA]500 800

102 102

300 600

106 106

400 700

98 98

200 50096 96

450 750

100 100

250 550550 850600 900650 950700 1000 1050

104 104

350 650

Relative forward voltage vs. forward current – tp 54 °C Relative forward voltage vs. forward current – tp 80 °C

Rel

ativ

e lu

min

ous

flux

[%]

Rel

ativ

e lu

min

ous

flux

[%]

tp [ºC] tp [ºC]

110 110

105105

100100

95

9590

90850 50 5090 90100 10040 4080 8030 3070 7020 60 6010

Relative luminuos flux vs. tp, for 350 mA If Relative luminuos flux vs. tp, for 700 mA If

700 mA

350 mA – Typical If 350 mA, Typical Vf 99.78 V,

Typical power 34.9 W, Nominal tp of LED 54 ºC

CRI 70

CCT [K]Optical variant

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 5267 151

3000 ME 24º 5222 150

3000 WI 28º 4992 143

3000 EW 48º 4854 139

3000 EL 20/40º 5015 144

3000 OV 110º 3908 112

3000 CV 125º 5072 145

4000 NA 22º 5657 162

4000 ME 24º 5607 161

4000 WI 28º 5361 154

4000 EW 48º 5213 149

4000 EL 20/40º 5386 154

4000 OV 110º 4196 120

4000 CV 125º 5447 156

5000 NA 22º 5532 158

5000 ME 24º 5484 157

5000 WI 28º 5243 150

5000 EW 48º 5098 146

5000 EL 20/40º 5267 151

5000 OV 110º 4104 118

5000 CV 125º 5327 153

CRI 80

CCT [K]Optical variant

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 4604 132

3000 ME 24º 4564 131

3000 WI 28º 4363 125

3000 EW 48º 4243 121

3000 EL 20/40º 4383 126

3000 OV 110º 3415 98

3000 CV 125º 4433 127

4000 NA 22ºº 4844 139

4000 ME 24º 4802 138

4000 WI 28º 4591 131

4000 EW 48º 4464 128

4000 EL 20/40º 4612 132

4000 OV 110º 3594 103

4000 CV 125º 4665 134

5000 NA 22º 4810 138

5000 ME 24º 4768 137

5000 WI 28º 4559 131

5000 EW 48º 4433 127

5000 EL 20/40º 4580 131

5000 OV 110º 3568 102

5000 CV 125º 4632 133

700 mA – Typical If 700 mA, Typical Vf 102.97 V,

Typical power 72.1 W, Nominal tp of LED 80 ºC

CRI 70

CCT [K]Optical variant

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 9053 126

3000 ME 24º 8974 125

3000 WI 28º 8580 119

3000 EW 48º 8343 116

3000 EL 20/40º 8619 120

3000 OV 110º 6716 93

3000 CV 125º 8718 121

4000 NA 22º 9723 135

4000 ME 24º 9638 134

4000 WI 28º 9214 128

4000 EW 48º 8960 124

4000 EL 20/40º 9257 128

4000 OV 110º 7212 100

4000 CV 125º 9362 130

5000 NA 22º 9784 136

5000 ME 24º 9699 135

5000 WI 28º 9272 129

5000 EW 48º 9017 125

5000 EL 20/40º 9315 129

5000 OV 110º 7258 101

5000 CV 125º 9422 131

CRI 80

CCT [K]Optical variant

Typical flux [lm]

Typical efficacy [lm/W]

3000 NA 22º 7887 109

3000 ME 24º 7819 108

3000 WI 28º 7475 104

3000 EW 48º 7269 101

3000 EL 20/40º 7509 104

3000 OV 110º 5851 81

3000 CV 125º 7595 105

4000 NA 22º 8300 115

4000 ME 24º 8227 114

4000 WI 28º 7866 109

4000 EW 48º 7649 106

4000 EL 20/40º 7902 110

4000 OV 110º 6157 85

4000 CV 125º 7992 111

5000 NA 22º 8508 118

5000 ME 24º 8434 117

5000 WI 28º 8063 112

5000 EW 48º 7841 109

5000 EL 20/40º 8100 112

5000 OV 110º 6312 88

5000 CV 125º 8193 114

tp POINT

Page 15: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

273IN1 LED MODULES 26/

Isolines (E)

Illuminance values

Spot illuminance diagram

Football stadium / Layout

FOOTBALL STADIUM FLOOD LIGHTING

DETAILSDimensions: 122.88 x 82.88 mNumber of FORTIS: 288 (240 x NA + 48 x WI)Number of luminaires: 48 (40 x NA + 8 x WI)Luminaire load: 440 WLuminaire output: 60,900 lm / 4000 K

ACHIEVED VALUESTotal luminous flux: 2,923,200 lmTotal load: 21,120 WMaintenance factor: 0.8

Average illuminance: 195 lx (dir + indir with 7 interreflections)Reflective factor: 25 %Average luminance: 14.13 cd/m2

Uniformity: u0 = 0.53 (1:1.88), Emin / Emax = 2.70 (1:0.37)Connected load: 9.81 W/m2 = 1.00 W/m2/100 lx (area: 10,184.29 m2)

Example application

CAMPO FUTBOL Bº LA CONCEPCIONNotas Instalación: LUM. PRO 440WCliente: G.Código Proyecto: TECNICO ROSA Mª PASCUALFecha 03/11/2016

Notas40 UDS. PRO 440W 14º+8 UDS. PRO 440W 28º

Diseñador de Iluminación: LUX-MAY Manufacturas Plásticas May S.A.Dirección: Euba s/n 48340 Amorebieta-VizcayaTel.-Fax +34 946 308 180

Advertencias:

LITESTAR (c)OxyTech Srl www.oxytech.it Página 1

CAMPO FUTBOL Bº LA CONCEPCIONLUX-MAY Manufacturas Plásticas May S.A.

TECNICO ROSA Mª PASCUALEuba s/n 48340 Amorebieta-Vizcaya

03/11/2016+34 946 308 180

3.1 Valores de Iluminancia sobre: Plano de Trabajo_1O (x:4.74 y:8.04 z:0.00) Resultados Medio Mínimo Máximo Mín/Medio Mín/Máx Medio/Máx

DX:2.88 DY:2.88 Iluminancia Horizontal (E) 195 lux 104 lux 281 lux 0.54 0.37 0.69

Tipo Cálculo Dir.+Indir.(7 Interreflexiones)

X

Y

4.74 12.74 20.74 28.74 36.74 44.74 52.74 60.74 68.74 76.74 84.74 92.74 100.74 108.74

8.04

16.04

24.04

32.04

40.04

48.04

56.04

64.04

72.04

xy

z

114 117 104 212 271 245 211 182 154 138 138 154 182 211 245 271 212 104 117 114134 148 122 201 278 265 234 203 175 160 160 175 203 234 265 278 201 122 148 134141 164 135 170 239 250 233 207 183 170 170 183 207 233 250 239 170 135 164 141136 164 145 184 215 233 226 205 185 174 174 185 205 226 233 215 184 145 164 136126 156 147 204 230 230 224 206 186 175 175 186 206 224 230 230 204 147 156 126119 146 141 204 243 242 230 211 191 179 179 191 211 230 242 243 204 141 146 119127 144 137 190 243 250 237 219 199 189 189 199 219 237 250 243 190 137 144 127153 158 134 177 234 250 241 223 208 200 200 208 223 241 250 234 177 134 158 153180 183 132 168 222 241 239 227 215 210 210 215 227 239 241 222 168 132 183 180192 205 129 158 210 233 232 228 221 218 218 221 228 232 233 210 158 129 205 192196 216 128 151 203 226 228 227 224 223 223 224 227 228 226 203 151 128 216 196198 223 129 148 203 223 225 229 225 224 224 225 229 225 223 203 148 129 223 198196 216 128 151 203 226 228 227 224 223 223 224 227 228 226 203 151 128 216 196192 205 129 158 210 233 232 228 221 218 218 221 228 232 233 210 158 129 205 192180 183 132 168 222 241 239 227 215 210 210 215 227 239 241 222 168 132 183 180153 158 134 177 234 250 241 223 208 200 200 208 223 241 250 234 177 134 158 153127 144 137 190 243 250 237 219 199 189 189 199 219 237 250 243 190 137 144 127119 146 141 204 243 242 230 211 191 179 179 191 211 230 242 243 204 141 146 119126 156 147 204 230 230 224 206 186 175 175 186 206 224 230 230 204 147 156 126136 164 145 184 215 233 226 205 185 174 174 185 205 226 233 215 184 145 164 136141 164 135 170 239 250 233 207 183 170 170 183 207 233 250 239 170 135 164 141134 148 122 201 278 265 234 203 175 160 160 175 203 234 265 278 201 122 148 134114 117 104 212 271 245 211 182 154 138 138 154 182 211 245 271 212 104 117 114

Escala 1/800 CV= 0.205 No todos los puntos de medida son visibles

LITESTAR (c)OxyTech Srl www.oxytech.it Página 5

CAMPO FUTBOL Bº LA CONCEPCIONLUX-MAY Manufacturas Plásticas May S.A.

TECNICO ROSA Mª PASCUALEuba s/n 48340 Amorebieta-Vizcaya

03/11/2016+34 946 308 180

3.2 Curvas Isolux sobre: Plano de Trabajo_1_1O (x:4.74 y:8.04 z:0.00) Resultados Medio Mínimo Máximo Mín/Medio Mín/Máx Medio/Máx

DX:2.88 DY:2.88 Iluminancia Horizontal (E) 195 lux 104 lux 281 lux 0.54 0.37 0.69

Tipo Cálculo Dir.+Indir.(7 Interreflexiones)

X

Y

4.74 12.74 20.74 28.74 36.74 44.74 52.74 60.74 68.74 76.74 84.74 92.74 100.74 108.74

8.04

16.04

24.04

32.04

40.04

48.04

56.04

64.04

72.04

xy

z

140

140 140

140

140

140

140

140

140

160

160

160

160

160

160

180180

180

180

180

180

180

180

200

200

200

200

200

200

200

200

200

220

220

220

220

220

220

220

220220

220 220

240

240

240

240

240

Escala 1/800

LITESTAR (c)OxyTech Srl www.oxytech.it Página 6

CAMPO FUTBOL Bº LA CONCEPCIONLUX-MAY Manufacturas Plásticas May S.A.

TECNICO ROSA Mª PASCUALEuba s/n 48340 Amorebieta-Vizcaya

03/11/2016+34 946 308 180

3.3 Diagrama de Iluminancia Spot sobre: Plano de Trabajo_1_1_1O (x:4.74 y:8.04 z:0.00) Resultados Medio Mínimo Máximo Mín/Medio Mín/Máx Medio/Máx

DX:2.88 DY:2.88 Iluminancia Horizontal (E) 195 lux 104 lux 281 lux 0.54 0.37 0.69

Tipo Cálculo Dir.+Indir.(7 Interreflexiones)

X

Y

4.74 12.74 20.74 28.74 36.74 44.74 52.74 60.74 68.74 76.74 84.74 92.74 100.74 108.74

8.04

16.04

24.04

32.04

40.04

48.04

56.04

64.04

72.04

xy

z

0 31 62 94 125 156 187 218 249 281

Escala 1/800

LITESTAR (c)OxyTech Srl www.oxytech.it Página 7

Page 16: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

293IN1 LED MODULES 28/

Inspiration

Page 17: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

313IN1 LED MODULES 30/

Page 18: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

333IN1 LED MODULES 32/

Altum

ALTUM IP67 is a 3in1 LED module designed for use in high-

bay luminaires. It is available with a wide range of light

distributions and offers high efficacies, low glare, and highly

effective thermal management. The module is easy to design

into your own luminaires and so supports short development

cycles and rapid launching of new high-bay products.

LEDS• CCTs of 3000 K, 4000 K, and 5000 K• CRI 70 or 80

OPTICS• PMMA lens array with an LOR of 94 %• 5 different LIDC options to suit a range of illumination, installation,

and mounting height needs – spot, medium, wide, ultra wide, and asymmetric

THERMAL MANAGEMENT• Anodised extruded aluminium heat sink

EFFICACY• Up to 166 lm/W (excluding driver)

APPLICATION• ALTUM's lighting parameters and high IP65 rating make it ideal for use

in high-bay industrial applications and stadiums• Can be installed within luminaires or used alone

UPCOMING...

Page 19: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

353IN1 LED MODULES 34/

Mechanical design

Anodised extruded aluminium heat sink

Thermal interface material

Silicon gasket

Metal core PCB with Nichia 219C

hi-power LEDs

PMMA lens array

Optical design

The ALTUM optical system uses a PMMA lens array with an LOR of 94 %. The module is available with five different LIDCs to suit a range of illumination, installation, and mounting height specifications.

Spot (RS) 13º

Wide (W) 54º

Asymmetric (0) 31º x 116º

Medium (M) 28º

Ultra wide (WWW) 95º

30 8

11.4 5.3 71.4

175

90 41.4

162.

6

54.2

150

50

80

8 x /o 3.58 x /o 3.5

61

Page 20: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

373IN1 LED MODULES 36/

Inspiration

Page 21: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

393IN1 LED MODULES 38/

Page 22: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

413IN1 LED MODULES 40/

Plateo

PLATEO IP67 is a 3in1 LED module designed for use in

street luminaires. It is available with a wide range of light

distributions and offers high efficacies, low glare, and highly

effective thermal management. The module is easy to design

into your own luminaires and so supports short development

cycles and rapid launching of new street lighting products.

LEDS• CCTs of 3000 K, 4000 K, and 5000 K• CRI 70 or 80

OPTICS• PMMA lens array with an LOR of 94 %• 6 different LIDC options to suit a range of illumination, installation, and

mounting height needs – 5 x asymmetric variants and one symmetric

THERMAL MANAGEMENT• Anodised extruded aluminium heat sink

EFFICACY• Up to 166 lm/W (excluding driver)

APPLICATION• ALTUM's lighting parameters and high IP65 rating make it ideal for use

in street luminaire and industrial applications• Can be installed within luminaires or used alone

UPCOMING...

Page 23: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

433IN1 LED MODULES 42/

Optical design

The ALTUM optical system uses a PMMA lens array with an LOR of 94 %. The module is available with five different LIDCs to suit a range of illumination, installation, and mounting height specifications.

Symmetric (VSM) 140º

Aymmetric (T2)

Aymmetric (T3)

Aymmetric (T4)

Aymmetric (T3B)

Aymmetric (ME)Aymmetric (DWC)

Aymmetric (T2B)

Mechanical design

30 8

11.4 5.3 71.4

175

90 41.4

162.

6

54.2

150

50

80

8 x /o 3.58 x /o 3.5

61

Anodised extruded aluminium heat sink

Thermal interface material

Silicon gasket

Metal core PCB with Nichia 219C

hi-power LEDs

PMMA lens array

Page 24: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

453IN1 LED MODULES 44/

Inspiration

Page 25: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

473IN1 LED MODULES 46/

Page 26: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

About iLumTech

PROVIDING THE PERFECT SOLUTION IS NOT JUST OUR JOB. IT IS OUR PASSION.

iLumTech is a market-leading research and development company that blends technology, creativity, and engineering to help customers transform their ideas into world-class products and solutions that follow global trends, focus on energy efficiency and cost reduction, and ensure wellbeing for all. With almost 90 engineers, extensive expertise across optical, thermal, electronic, and mechanical engineering as well as software and hardware design, we are in a position to provide uniquely comprehensive services.

Located in the heart of Europe, we hold a unique position within the research and development field thanks to time-proven capabilities in luminaire, technology, and user experience design, and development and engineering for a wide variety of industries. We leverage this valuable skill set to help our customers create exceptional products, services, and experiences that drive their strategic growth.

It is our goal to become the preferred partner for customers wanting world-class products and differentiated solutions based on our professional services, continued innovation, and use and development of cutting-edge technologies.

SERVICES• Turnkey full luminaire development• Optical design and laboratory services, and lens manufacture• Electronic design and laboratory services, DALI testing, and electronics

manufacture• Hardware, firmware, software, and labware design• Industrial design and product promotion• Mechanical engineering• Thermal design and laboratory services• Prototyping and 3D printing

PRODUCT PORTFOLIO• Control and sensing devices for luminaires• Internet of Things devices• DALI PowerLine Communication• Optical components for the lighting industry• 3in1 LED units for the lighting market• Street lighting management system

Page 27: easy, effective, elegant 3in1 LED Modules · 2017. 3. 28. · 3IN1 LED MODULES 4/5 Infinitas LEDS • Net lumen output of up to 1100 lm • UGR 21/24 (as low as UGR 16 in situ) •

iLumTech Industries, s. r. o.Čáčovská cesta 2709/4 Senica 905 01SlovakiaTel: +421 (0)34 694 0847Email: [email protected]