Earth-Rite® MULTIPOINT II - Redlands

36
Installation and Operating Instructions READ MANUAL BEFORE COMMENCING WITH INSTALLATION Earth ® -Rite MULTIPOINT II Static Ground Monitoring System The safety of any system incorporating the equipment referred to in this manual is the responsibility of the installer of the system. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Any warranty is made void if the equipment is not installed, or used, in accordance with the manufacturers instructions. www.newson-gale.com US

Transcript of Earth-Rite® MULTIPOINT II - Redlands

Page 1: Earth-Rite® MULTIPOINT II - Redlands

# 1

Installation and Operating Instructions

READ MANUALBEFORE COMMENCINGWITH INSTALLATION

Earth ®-Rite MULTIPOINT IIStatic Ground Monitoring System

The safety of any system incorporating the equipment referred to in this manual is the responsibility of the installer of the system. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Any warranty is made void if the equipment is not installed, or used, in accordance with the manufacturers instructions.

www.newson-gale.com

US

Page 2: Earth-Rite® MULTIPOINT II - Redlands

2 3

CONTENTS

Page

System Plan 9

Recommended Cable Specification 7

Product Overview 3

Typical Installation Examples 10

Important Safety Precautions 4

Installation Overview 5

User instructions, Including Instructions for safe selection,

Control Drawings 26

installation, use, maintenance and repair 20

Typical Operation 21

Earth-Rite MULTIPOINT II Technical Specification 30

Marking Drawings 22

Group Relay Setting 14

Dimensions 24

Channel Setting 17

Fault Relay 16

Conversion Tables 28

Earth-Rite MULTIPOINT II solves these problems by ensuring that all parts of the equipment are connected together

and to ground by using a unique Intrinsically Safe monitoring system. This is achieved by powering the monitoring

system from a single I.S. Supply. The Monitoring Unit may be used to monitor up to eight separate points. The

system provides permissive outputs only when the ground loop resistance of each utilised channel is less than 10

Ohms, as recommended in the various International standards for the control of undesirable static electricity. The

Earth-Rite MULTIPOINT II may be used to provide status indication for the equipment, or automatically linked back

to a control system to prevent operation until the required bonding and grounding conditions have been achieved.

The system has cCSAus, ATEX and IECEx approval for use in hazardous atmospheres and meets all current EC

directives.

One such application exists with items of process plant incorporating sections, which must be removed periodically

for cleaning, product discharge or other purposes. A typical example of this is the product bowl on a Fluid Bed

Dryer, but there are many other similar applications such as ductwork sections, conveying systems etc.

PRODUCT OVERVIEW

The problem of static electricity in hazardous atmospheres is ever present in many sectors of the processing

industries. Effective grounding and bonding procedures are always the first step in controlling static, with special

techniques being called for to suit individual applications.

In these instances the possibility exists that the removable parts may become isolated conductors if they do not

have a sufficiently low resistance path to ground to enable any static generated to safely dissipate. If this happens,

high levels of charge may accumulate on the isolated part, posing the risk of energetic static discharges (sparks). If

this occurs in a hazardous atmosphere there will be a chance of a resulting fire, explosion or dangerous

physiological shocks for operators.

www.newson-gale.comwww.newson-gale.com

Page 3: Earth-Rite® MULTIPOINT II - Redlands

2 3

CONTENTS

Page

System Plan 9

Recommended Cable Specification 7

Product Overview 3

Typical Installation Examples 10

Important Safety Precautions 4

Installation Overview 5

User instructions, Including Instructions for safe selection,

Control Drawings 26

installation, use, maintenance and repair 20

Typical Operation 21

Earth-Rite MULTIPOINT II Technical Specification 30

Marking Drawings 22

Group Relay Setting 14

Dimensions 24

Channel Setting 17

Fault Relay 16

Conversion Tables 28

Earth-Rite MULTIPOINT II solves these problems by ensuring that all parts of the equipment are connected together

and to ground by using a unique Intrinsically Safe monitoring system. This is achieved by powering the monitoring

system from a single I.S. Supply. The Monitoring Unit may be used to monitor up to eight separate points. The

system provides permissive outputs only when the ground loop resistance of each utilised channel is less than 10

Ohms, as recommended in the various International standards for the control of undesirable static electricity. The

Earth-Rite MULTIPOINT II may be used to provide status indication for the equipment, or automatically linked back

to a control system to prevent operation until the required bonding and grounding conditions have been achieved.

The system has cCSAus, ATEX and IECEx approval for use in hazardous atmospheres and meets all current EC

directives.

One such application exists with items of process plant incorporating sections, which must be removed periodically

for cleaning, product discharge or other purposes. A typical example of this is the product bowl on a Fluid Bed

Dryer, but there are many other similar applications such as ductwork sections, conveying systems etc.

PRODUCT OVERVIEW

The problem of static electricity in hazardous atmospheres is ever present in many sectors of the processing

industries. Effective grounding and bonding procedures are always the first step in controlling static, with special

techniques being called for to suit individual applications.

In these instances the possibility exists that the removable parts may become isolated conductors if they do not

have a sufficiently low resistance path to ground to enable any static generated to safely dissipate. If this happens,

high levels of charge may accumulate on the isolated part, posing the risk of energetic static discharges (sparks). If

this occurs in a hazardous atmosphere there will be a chance of a resulting fire, explosion or dangerous

physiological shocks for operators.

www.newson-gale.comwww.newson-gale.com

Page 4: Earth-Rite® MULTIPOINT II - Redlands

4 5

GENERAL

INSTALLATION OVERVIEW

The installation must comply with the installation requirements of the country of use. e.g.Canada: CSA C22.2 No. 0-M (General Requirements - Canadian Electrical Code, Part II)USA: ANSI.ISA RP12.06.01 (Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations) and the National Electrical Code.

In addition, the installation must be in accordance with the manufacture’s guidelines.

All cables entering the Power Supply Unit, must be connected through approved cable glands.

The glands should be fitted in such a way as to maintain the ingress protection rating of the enclosure.

Cables connected within the Power Supply Unit shall be suitably temperature rated.

Unused cable entries must be fitted with suitable stopper plugs.

The Earth-Rite MULTIPOINT II system can be powered from a range of supply voltages.

After installation of wiring, replace the enclosure covers, making sure they are tight.

The installation shall be carried out by suitably trained personnel.

The system should be connected as per the enclosed installation drawings.

The Monitoring Unit and Remote Indicator Stations should be mounted, with the indicators facing away from direct sunlight, at a convenient location, visible to the operator.

NOTE: Cables must be secured close to the enclosure in order to prevent them being accidentally pulled out.

It is recommended that the transfer or mixing operation is interlocked with the contacts of the Earth-Rite MULTIPOINT II unit. This will ensure that the operation is stopped if the earth connection is inadvertently lost.

The Power Supply Unit should be protected using a 2A fast blow fuse, or circuit breaker, mounted in the distribution board / fuse box.

Cables connected within the Power Supply Unit shall have a flammability classification of VW-1, equivalent or better.

Maintenance: Periodically check exterior of all enclosures for damage or deterioration.

IF YOU HAVE ANY QUERIES REGARDING THE ABOVE POINTS THEN PLEASE CONTACT NEWSON GALE, OR THEIR APPROVED DISTRIBUTOR, WITHOUT DELAY.

OTHER APPROVALS

Electromagnetic Compatibility

The Earth-Rite MULTIPOINT II has been tested and shown conformity to European Directive 2004/108/EC, and FCC Part 15 Emissions. Conformity has been proven to BS EN 61000-6-3 and BS EN 61000-6-2.

Install in accordance with the manufacturer's instructions.

Servicing is required when the apparatus has been damaged in any way, such as if liquid has been spilled or

objects have fallen into any of the Earth-Rite MULTIPOINT II enclosures, or the equipment does not operate as

intended, or has been dropped.

DETAILED SAFETY INSTRUCTIONS:

Connector PL10, on the Monitoring PCB, should be accessed only by a Newson Gale engineer and in a safe

area.

The external ground-terminal of the Monitoring Unit enclosure must be connected to ground in order to

dissipate any charge safely away from the enclosure.

Disposal of the Earth-Rite MULTIPOINT II

At the end of it’s life the Earth-Rite MULTIPOINT II should be disposed of in a safe, considerate,

environmentally friendly manner.

Important Safety Precautions

The Earth-Rite MULTIPOINT II should be taken out of service if it shows signs of damage or liquid/dust

ingress.

Read these instructions. Keep these instructions. Heed all warnings.

Follow all instructions.

Refer all servicing to qualified service personnel.

This symbol, wherever it appears, alerts you to important instructions.

Do not allow water to enter any of the enclosures.

Do not install near any heat sources.

All wiring should be as sown in this manual. Alternative wiring arrangements are not recommended as they

may infringe the certification requirements.

DO NOT OPEN THE POWER SUPPLY UNIT ENCLOSURE WHEN AN EXPLOSIVE GAS AND/OR DUST

ATMOSPHERE MAY BE PRESENT.

The Earth-Rite MULTIPOINT II Monitoring Circuit must have a connection to a verifiable ground point in order

to dissipate static electricity.

Connector PL1, on the Power Supply PCB, should be accessed only by a Newson Gale engineer and in a

safe area.

The system shall be installed as per the control drawing X MPII Q15152 cCSAus.

www.newson-gale.comwww.newson-gale.com

Page 5: Earth-Rite® MULTIPOINT II - Redlands

4 5

GENERAL

INSTALLATION OVERVIEW

The installation must comply with the installation requirements of the country of use. e.g.Canada: CSA C22.2 No. 0-M (General Requirements - Canadian Electrical Code, Part II)USA: ANSI.ISA RP12.06.01 (Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations) and the National Electrical Code.

In addition, the installation must be in accordance with the manufacture’s guidelines.

All cables entering the Power Supply Unit, must be connected through approved cable glands.

The glands should be fitted in such a way as to maintain the ingress protection rating of the enclosure.

Cables connected within the Power Supply Unit shall be suitably temperature rated.

Unused cable entries must be fitted with suitable stopper plugs.

The Earth-Rite MULTIPOINT II system can be powered from a range of supply voltages.

After installation of wiring, replace the enclosure covers, making sure they are tight.

The installation shall be carried out by suitably trained personnel.

The system should be connected as per the enclosed installation drawings.

The Monitoring Unit and Remote Indicator Stations should be mounted, with the indicators facing away from direct sunlight, at a convenient location, visible to the operator.

NOTE: Cables must be secured close to the enclosure in order to prevent them being accidentally pulled out.

It is recommended that the transfer or mixing operation is interlocked with the contacts of the Earth-Rite MULTIPOINT II unit. This will ensure that the operation is stopped if the earth connection is inadvertently lost.

The Power Supply Unit should be protected using a 2A fast blow fuse, or circuit breaker, mounted in the distribution board / fuse box.

Cables connected within the Power Supply Unit shall have a flammability classification of VW-1, equivalent or better.

Maintenance: Periodically check exterior of all enclosures for damage or deterioration.

IF YOU HAVE ANY QUERIES REGARDING THE ABOVE POINTS THEN PLEASE CONTACT NEWSON GALE, OR THEIR APPROVED DISTRIBUTOR, WITHOUT DELAY.

OTHER APPROVALS

Electromagnetic Compatibility

The Earth-Rite MULTIPOINT II has been tested and shown conformity to European Directive 2004/108/EC, and FCC Part 15 Emissions. Conformity has been proven to BS EN 61000-6-3 and BS EN 61000-6-2.

Install in accordance with the manufacturer's instructions.

Servicing is required when the apparatus has been damaged in any way, such as if liquid has been spilled or

objects have fallen into any of the Earth-Rite MULTIPOINT II enclosures, or the equipment does not operate as

intended, or has been dropped.

DETAILED SAFETY INSTRUCTIONS:

Connector PL10, on the Monitoring PCB, should be accessed only by a Newson Gale engineer and in a safe

area.

The external ground-terminal of the Monitoring Unit enclosure must be connected to ground in order to

dissipate any charge safely away from the enclosure.

Disposal of the Earth-Rite MULTIPOINT II

At the end of it’s life the Earth-Rite MULTIPOINT II should be disposed of in a safe, considerate,

environmentally friendly manner.

Important Safety Precautions

The Earth-Rite MULTIPOINT II should be taken out of service if it shows signs of damage or liquid/dust

ingress.

Read these instructions. Keep these instructions. Heed all warnings.

Follow all instructions.

Refer all servicing to qualified service personnel.

This symbol, wherever it appears, alerts you to important instructions.

Do not allow water to enter any of the enclosures.

Do not install near any heat sources.

All wiring should be as sown in this manual. Alternative wiring arrangements are not recommended as they

may infringe the certification requirements.

DO NOT OPEN THE POWER SUPPLY UNIT ENCLOSURE WHEN AN EXPLOSIVE GAS AND/OR DUST

ATMOSPHERE MAY BE PRESENT.

The Earth-Rite MULTIPOINT II Monitoring Circuit must have a connection to a verifiable ground point in order

to dissipate static electricity.

Connector PL1, on the Power Supply PCB, should be accessed only by a Newson Gale engineer and in a

safe area.

The system shall be installed as per the control drawing X MPII Q15152 cCSAus.

www.newson-gale.comwww.newson-gale.com

Page 6: Earth-Rite® MULTIPOINT II - Redlands

6 7

100ft of 12 AWG copper cable has resistance of 0.16

100m of 2.5mm sq copper cable has a resistance of 0.69

Length Cable Size and Type Ohms

100ft of 18(UL) AWG copper cable has resistance of 0.53

100ft of 14 AWG copper cable has resistance of 0.25

100m of 1.5mm sq copper cable has a resistance of 1.13

100m of 1.0mm sq copper cable has a resistance of 1.73

100m of 4.0mm sq copper cable has a resistance of 0.43

Earth-Rite MULTIPOINT II

Approved Cable Parameters

Cable resistance values

The resistance figure shown should be multiplied by 2 to give the loop resistance.

Earth-Rite MULTIPOINT II - Customer Supplied Cable Specification

10AWG single-conductor cable with orange sheath.

Cable from Earth-Rite MULTIPOINT II Power Supply Unit to the Pump/Mixer/etc control circuit

Recommended Specification

Cable from Earth-Rite MULTIPOINT II Monitoring Unit to the Earth-Rite MULTIPOINT II Marshalling Box 18AWG multi-conductor Cable with blue sheath or identifier (IS Circuit).

Cable from Earth-Rite MULTIPOINT II Monitoring Unit to Earth-Rite MULTIPOINT II Power Supply Unit 18AWG 4-conductor Cable with blue sheath or identifier (IS Circuit). [Maximum Length: 200m]

Cable from the Site Static Ground Bar/Tape to the Earth-Rite MULTIPOINT II Marshalling Box 10AWG single-conductor cable with orange sheath.

14AWG 2-conductor cable + Equipment Grounding Conductor

Cable from the Earth-Rite MULTIPOINT II Marshalling Box to each Remote Indicator Station

Typical Installation – using Newson Gale Clamps, Cables etc for Plant-Item Connections

18(UL) AWG 5-conductor Cable with blue sheath or identifier (IS Circuit).

Cable from Earth-Rite MULTIPOINT II Monitoring unit to Site Static Ground Bar/Tape

Cable from Supply to the Earth-Rite MULTIPOINT II Power Supply Unit

Insulation of cables connected to the Power Supply Unit

14AWG 2-conductor cable + Equipment Grounding Conductor

All cables connected to the non-Intrinsically Safe terminals of the Power Supply Unit shall have adequate insulation to suit the voltage and the environmental conditions. The insulation for all cables should be rated to at least 500V.

Maximum Relative Humidity 100%

Remote Indicator Station IP66

IF YOU ARE IN ANY DOUBT REGARDING THE INSTALLATION THEN PLEASE CONTACT NEWSON GALE, OR THEIR APPROVED DISTRIBUTOR, WITHOUT DELAY.

Marshalling Junction Box IP66

This data can be used by the installer, in conjunction with the table below, to determine the maximum allowed cable length.

Environmental Conditions

o o o oAmbient Temperature Range -40 F to +140 F (-40 C to +60 C)

Maximum Cable Length Considerations for the Earth-Rite MULTIPOINT II Intrinsically Safe Circuits

The equipment is designed to be used both indoors and outdoors in hazardous atmospheres.

The Ingress Protection ratings of the various parts of the equipment are as follows:

Power Supply Unit IP66, NEMA 4X

The Intrinsically Safe cables connected to the Earth-Rite MULTIPOINT II are restricted in length by three I.S. Parameters, namely C (capacitance), L (inductance) and the L/R ratio. The cable parameters correspond to the output parameters of the equipment (Co, Lo & Lo/Ro).

Consideration must also be given to the resistance of the cable loops as the Earth-Rite MULTIPOINT II monitors to a maximum resistance of 10 ohm per channel.

Mains supply voltage fluctuations Up to +/- 10% of the nominal voltage

Transient Over-voltages levels Up to the levels of Category II of IEC 61010-1: 2010 Clause 6.7

Temporary Over-voltages In accordance with IEC 61010-1: 2010 Clause 6.7

Altitude up to 5000m

In addition, all installations must be carried out in accordance with any relevant national standards and requirements.

Monitoring Unit IP66, NEMA 4X

Applicable pollution degree Degree 2

Note: The tightening torque for the green Ex e terminals, of the Power Supply Unit, is 0.4 Nm minimum to 0.5 Nm maximum.

The IEC code of practice (IEC 60079-14) suggests practical maximum cable parameters, for C, L and the L/R ratio, as 200pf/m, 1μH/m and 30 μH/ohm respectively. However, cable manufacturers generally publish specific data for their cables.

For operational purposes, the cable between the Power Supply Unit and the Monitoring Unit should be no more than 200m (218 Yards) in length.

NEC / CEC Class and Zone Groups

External Inductance (PSU to Monitor Unit )

External Inductance (Monitor Unit field wiring terminals) Lo

External Capacitance (PSU to Monitor Unit )

External Lo/Ro (PSU to Monitor Unit )

1.5uF 9.9uF 39uF

208uH 833uH 1667uH

29.1 uH/ohm 117 uH/ohm 234 uH/ohm

External Capacitance (Monitor Unit field wiring terminals) Co

External Lo/Ro (Monitor Unit field wiring terminals) Lo/Ro

1.5uF 9.9uF 39uF

1022uH 4088uH 8175uH

68 uH/ohm 272 uH/ohm 544 uH/ohm

NEC / CEC Class & Division Groups Class I Group A Class I Group C Class I Group DClass I Group BClass II Group E

Class II Group F Class IIIClass II Group G

Class I Group IIC Class I Group IIB Class I Group IIAClass II Group IIIC Class II Group IIIB Class III Group IIIA

Item

www.newson-gale.comwww.newson-gale.com

Page 7: Earth-Rite® MULTIPOINT II - Redlands

6 7

100ft of 12 AWG copper cable has resistance of 0.16

100m of 2.5mm sq copper cable has a resistance of 0.69

Length Cable Size and Type Ohms

100ft of 18(UL) AWG copper cable has resistance of 0.53

100ft of 14 AWG copper cable has resistance of 0.25

100m of 1.5mm sq copper cable has a resistance of 1.13

100m of 1.0mm sq copper cable has a resistance of 1.73

100m of 4.0mm sq copper cable has a resistance of 0.43

Earth-Rite MULTIPOINT II

Approved Cable Parameters

Cable resistance values

The resistance figure shown should be multiplied by 2 to give the loop resistance.

Earth-Rite MULTIPOINT II - Customer Supplied Cable Specification

10AWG single-conductor cable with orange sheath.

Cable from Earth-Rite MULTIPOINT II Power Supply Unit to the Pump/Mixer/etc control circuit

Recommended Specification

Cable from Earth-Rite MULTIPOINT II Monitoring Unit to the Earth-Rite MULTIPOINT II Marshalling Box 18AWG multi-conductor Cable with blue sheath or identifier (IS Circuit).

Cable from Earth-Rite MULTIPOINT II Monitoring Unit to Earth-Rite MULTIPOINT II Power Supply Unit 18AWG 4-conductor Cable with blue sheath or identifier (IS Circuit). [Maximum Length: 200m]

Cable from the Site Static Ground Bar/Tape to the Earth-Rite MULTIPOINT II Marshalling Box 10AWG single-conductor cable with orange sheath.

14AWG 2-conductor cable + Equipment Grounding Conductor

Cable from the Earth-Rite MULTIPOINT II Marshalling Box to each Remote Indicator Station

Typical Installation – using Newson Gale Clamps, Cables etc for Plant-Item Connections

18(UL) AWG 5-conductor Cable with blue sheath or identifier (IS Circuit).

Cable from Earth-Rite MULTIPOINT II Monitoring unit to Site Static Ground Bar/Tape

Cable from Supply to the Earth-Rite MULTIPOINT II Power Supply Unit

Insulation of cables connected to the Power Supply Unit

14AWG 2-conductor cable + Equipment Grounding Conductor

All cables connected to the non-Intrinsically Safe terminals of the Power Supply Unit shall have adequate insulation to suit the voltage and the environmental conditions. The insulation for all cables should be rated to at least 500V.

Maximum Relative Humidity 100%

Remote Indicator Station IP66

IF YOU ARE IN ANY DOUBT REGARDING THE INSTALLATION THEN PLEASE CONTACT NEWSON GALE, OR THEIR APPROVED DISTRIBUTOR, WITHOUT DELAY.

Marshalling Junction Box IP66

This data can be used by the installer, in conjunction with the table below, to determine the maximum allowed cable length.

Environmental Conditions

o o o oAmbient Temperature Range -40 F to +140 F (-40 C to +60 C)

Maximum Cable Length Considerations for the Earth-Rite MULTIPOINT II Intrinsically Safe Circuits

The equipment is designed to be used both indoors and outdoors in hazardous atmospheres.

The Ingress Protection ratings of the various parts of the equipment are as follows:

Power Supply Unit IP66, NEMA 4X

The Intrinsically Safe cables connected to the Earth-Rite MULTIPOINT II are restricted in length by three I.S. Parameters, namely C (capacitance), L (inductance) and the L/R ratio. The cable parameters correspond to the output parameters of the equipment (Co, Lo & Lo/Ro).

Consideration must also be given to the resistance of the cable loops as the Earth-Rite MULTIPOINT II monitors to a maximum resistance of 10 ohm per channel.

Mains supply voltage fluctuations Up to +/- 10% of the nominal voltage

Transient Over-voltages levels Up to the levels of Category II of IEC 61010-1: 2010 Clause 6.7

Temporary Over-voltages In accordance with IEC 61010-1: 2010 Clause 6.7

Altitude up to 5000m

In addition, all installations must be carried out in accordance with any relevant national standards and requirements.

Monitoring Unit IP66, NEMA 4X

Applicable pollution degree Degree 2

Note: The tightening torque for the green Ex e terminals, of the Power Supply Unit, is 0.4 Nm minimum to 0.5 Nm maximum.

The IEC code of practice (IEC 60079-14) suggests practical maximum cable parameters, for C, L and the L/R ratio, as 200pf/m, 1μH/m and 30 μH/ohm respectively. However, cable manufacturers generally publish specific data for their cables.

For operational purposes, the cable between the Power Supply Unit and the Monitoring Unit should be no more than 200m (218 Yards) in length.

NEC / CEC Class and Zone Groups

External Inductance (PSU to Monitor Unit )

External Inductance (Monitor Unit field wiring terminals) Lo

External Capacitance (PSU to Monitor Unit )

External Lo/Ro (PSU to Monitor Unit )

1.5uF 9.9uF 39uF

208uH 833uH 1667uH

29.1 uH/ohm 117 uH/ohm 234 uH/ohm

External Capacitance (Monitor Unit field wiring terminals) Co

External Lo/Ro (Monitor Unit field wiring terminals) Lo/Ro

1.5uF 9.9uF 39uF

1022uH 4088uH 8175uH

68 uH/ohm 272 uH/ohm 544 uH/ohm

NEC / CEC Class & Division Groups Class I Group A Class I Group C Class I Group DClass I Group BClass II Group E

Class II Group F Class IIIClass II Group G

Class I Group IIC Class I Group IIB Class I Group IIAClass II Group IIIC Class II Group IIIB Class III Group IIIA

Item

www.newson-gale.comwww.newson-gale.com

Page 8: Earth-Rite® MULTIPOINT II - Redlands

8 9

Earth-Rite MULTIPOINT II - SYSTEM PLAN

Canada/USA:

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 0, Group IIC; Class II, Zone 20, Group IIIC

Canada/USA:

Class I, Div. 2, Groups A, B, C, D;Class II, Div. 1, Groups E, F, G;Class III, Div. 1;

Class I, Zone 2, Group IIC;Class II, Zone 21, Group IIIC

Or Unclassified Location

Earth-RiteMULTIPOINT II

Marshalling Box

115/230V 50/60HzSUPPLY

CUSTOMERINTERLOCKCIRCUITS(up to 8)

VERIFIABLE STATICEARTH POINT

(Resistance to Groundmust be <10 ohm)

Remote Indicator Station with LEDs andClamp Stowage Pin

CLAMP

CLAMP

CUSTOMER’S STATIC GROUND BUS/TAPE

12" (300mm) Maximum

Earth-RiteMULTIPOINT IIMonitoring Unit

Earth-RiteMULTIPOINT II

Power Supply Unit

The system monitors the static dissipation path, from the object to which the Static Grounding Clamp or lead is connected to, as far as the Static Ground Point. It is the responsibility of the end user to provide the Static Earth Point and ensure that it is suitable for dissipating electrostatic charges. This Ground should be close to the working area.

Verification of the Static Ground Point

Approved Cable Parameters

Canada/USA:

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 0, Group IIC; Class II, Zone 20, Group IIIC

Canada/USA:

Class I, Div. 2, Groups A, B, C, D;Class II, Div. 1, Groups E, F, G;Class III, Div. 1;

Class I, Zone 2, Group IIC;Class II, Zone 21, Group IIIC

Or Unclassified Location

Earth-Rite MULTIPOINT IIPower Supply Unit

Earth-RiteMULTIPOINT IIMonitoring Unit

Total maximum Inductance / Capacitance / L/R of cable connected to field wiring terminals 1 to 27. See table below.

NEC / CEC Class and Zone Groups

External Inductance (PSU to Monitor Unit )

External Inductance (Monitor Unit field wiring terminals) Lo

External Capacitance (PSU to Monitor Unit )

External Lo/Ro (PSU to Monitor Unit )

1.5uF 9.9uF 39uF

208uH 833uH 1667uH

29.1 uH/ohm 117 uH/ohm 234 uH/ohm

External Capacitance (Monitor Unit field wiring terminals) Co

External Lo/Ro (Monitor Unit field wiring terminals) Lo/Ro

1.5uF 9.9uF 39uF

1022uH 4088uH 8175uH

68 uH/ohm 272 uH/ohm 544 uH/ohm

NEC / CEC Class & Division Groups Class I Group A Class I Group C Class I Group DClass I Group BClass II Group E

Class II Group F Class IIIClass II Group G

Class I Group IIC Class I Group IIB Class I Group IIAClass II Group IIIC Class II Group IIIB Class III Group IIIA

Item

www.newson-gale.comwww.newson-gale.com

Page 9: Earth-Rite® MULTIPOINT II - Redlands

8 9

Earth-Rite MULTIPOINT II - SYSTEM PLAN

Canada/USA:

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 0, Group IIC; Class II, Zone 20, Group IIIC

Canada/USA:

Class I, Div. 2, Groups A, B, C, D;Class II, Div. 1, Groups E, F, G;Class III, Div. 1;

Class I, Zone 2, Group IIC;Class II, Zone 21, Group IIIC

Or Unclassified Location

Earth-RiteMULTIPOINT II

Marshalling Box

115/230V 50/60HzSUPPLY

CUSTOMERINTERLOCKCIRCUITS(up to 8)

VERIFIABLE STATICEARTH POINT

(Resistance to Groundmust be <10 ohm)

Remote Indicator Station with LEDs andClamp Stowage Pin

CLAMP

CLAMP

CUSTOMER’S STATIC GROUND BUS/TAPE

12" (300mm) Maximum

Earth-RiteMULTIPOINT IIMonitoring Unit

Earth-RiteMULTIPOINT II

Power Supply Unit

The system monitors the static dissipation path, from the object to which the Static Grounding Clamp or lead is connected to, as far as the Static Ground Point. It is the responsibility of the end user to provide the Static Earth Point and ensure that it is suitable for dissipating electrostatic charges. This Ground should be close to the working area.

Verification of the Static Ground Point

Approved Cable Parameters

Canada/USA:

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 0, Group IIC; Class II, Zone 20, Group IIIC

Canada/USA:

Class I, Div. 2, Groups A, B, C, D;Class II, Div. 1, Groups E, F, G;Class III, Div. 1;

Class I, Zone 2, Group IIC;Class II, Zone 21, Group IIIC

Or Unclassified Location

Earth-Rite MULTIPOINT IIPower Supply Unit

Earth-RiteMULTIPOINT IIMonitoring Unit

Total maximum Inductance / Capacitance / L/R of cable connected to field wiring terminals 1 to 27. See table below.

NEC / CEC Class and Zone Groups

External Inductance (PSU to Monitor Unit )

External Inductance (Monitor Unit field wiring terminals) Lo

External Capacitance (PSU to Monitor Unit )

External Lo/Ro (PSU to Monitor Unit )

1.5uF 9.9uF 39uF

208uH 833uH 1667uH

29.1 uH/ohm 117 uH/ohm 234 uH/ohm

External Capacitance (Monitor Unit field wiring terminals) Co

External Lo/Ro (Monitor Unit field wiring terminals) Lo/Ro

1.5uF 9.9uF 39uF

1022uH 4088uH 8175uH

68 uH/ohm 272 uH/ohm 544 uH/ohm

NEC / CEC Class & Division Groups Class I Group A Class I Group C Class I Group DClass I Group BClass II Group E

Class II Group F Class IIIClass II Group G

Class I Group IIC Class I Group IIB Class I Group IIAClass II Group IIIC Class II Group IIIB Class III Group IIIA

Item

www.newson-gale.comwww.newson-gale.com

Page 10: Earth-Rite® MULTIPOINT II - Redlands

10 11

Ch 1

Ch 2

Ch 3

Ch 4

Ch 5

Ch 6

Ch 7

Ch 8

To M

PII

P

ow

er

Su

pp

ly

Un

it

Ea

rth

-Rite

Mu

ltip

oin

t II

Re

mo

te I

nd

ica

tor

Sta

tion

s

Ea

rth

-Rite

M

ulti

po

int

IIM

ars

ha

llin

g B

ox

Ea

rth-R

ite M

ulti

po

int

II M

on

itorin

g U

nit

1 2 3

4 4 4 4 4 4

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

Cla

mp

sa

nd

Ca

ble

s

CA

N-

CA

N+

0V

+V

7 8 9

26

10

11 12

13

14

15

16

17

18

19

20

21

22

23

24

Channel S

tatu

sIn

dic

ato

rs(U

nhealth

y)

Watc

h D

og (

Sys

tem

Sta

tus

Indic

ato

r)

4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/ T

AP

E

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

Term

inals

26 a

nd 2

7

are

inte

rnally

connect

ed togeth

er

LR

C1

LR

C2

LR

C3

LR

C4

LR

C5

LR

C6

LR

C7

25 M

ain

LE

D R

etu

rn

LR

C8

Spare

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

To V

erifia

ble

G

round P

oin

t

CR

8

Gro

und T

est

: After

inst

alla

tion a

nd d

uring c

om

mis

sionin

g

tem

pora

rily

dis

connect

the c

able

to term

inal 26/2

7 a

nd

ensu

re that th

e s

yste

m b

eco

mes

non-p

erm

issi

ve.

Channel S

tatu

sIn

dic

ato

rs(H

ealth

y)

Pow

er

Indic

ato

r

1 2 3 4 5 6 7 8

ON

Channel

Sele

ct

Sw

itch

SW

2

1 2 3 4 5 6 7 8

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s –

Us

ing

2-P

ole

Cla

mp

s a

nd

Ca

ble

s a

nd

Re

mo

te I

nd

ica

tor

Sta

tio

ns

1 2 3 4 5 6

Warn

ing

, T

he s

tain

less

ste

el e

ncl

osu

res a

re

fitte

d w

ith s

traps

to e

nsu

re that th

e li

d is a

t th

e

sam

e p

ote

ntia

l as

the e

ncl

osu

re b

ody.

Take

care

when r

em

ovi

ng a

nd fitt

ing the e

nclo

sure

lids. D

o n

ot re

move

these

str

aps

.

The e

xtern

al g

round-

term

inal o

f th

e M

PII

stain

less

ste

el e

ncl

osu

res

must

be c

onnecte

d

to g

round in

ord

er

to d

issi

pate

any

charg

e

safe

ly a

way

from

the e

ncl

osu

re.

These

tw

o c

able

s sh

ould

be term

inate

d o

nto

the

static

gro

und b

us;

separa

te

but no m

ore

than 1

2"

(300m

m) apart

.

www.newson-gale.comwww.newson-gale.com

Ch 1

Ch 2

Ch 3

Ch 4

Ch 5

Ch 6

Ch 7

Ch 8

To

MP

II

Po

we

r S

up

ply

Un

it

Junct

ion

Boxe

s

Eart

h-R

ite

Multi

poin

t II

Mars

halli

ng B

ox

Ea

rth

-Rite

Mu

ltip

oin

t II

Mo

nito

rin

g U

nit

1 2 3

4 4 4 4 4 4

Cla

mps

and C

able

s

CA

N-

CA

N+

0V

+V

26

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s–

Us

ing

2-P

ole

Cla

mp

s a

nd

Ca

ble

s

4 5 6 7 8 9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

1 2 3 4 5 6 7 8

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/T

AP

E

1 4 7 13

16

19

22

10

Watc

h D

og (

Sys

tem

S

tatu

s In

dic

ato

r)

Channel S

tatu

sIn

dic

ato

rs(H

ealthy)

Pow

er

Indic

ato

r

Channel S

tatu

sIn

dic

ato

rs(U

nhealthy)

1 2 3 4 5 6 7 8

O N

Channel

Sele

ct

Sw

itch

SW

2

Term

inals

26 a

nd 2

7

are

inte

rnally

co

nnect

ed togeth

er

Gro

und T

est

: A

fter

inst

alla

tion a

nd d

uring c

om

mis

sio

nin

g

tem

pora

rily

dis

connect

the c

able

to term

inal 26/

27 a

nd

ensu

re that th

e s

yste

m b

eco

mes n

on-p

erm

issiv

e.

To V

erifia

ble

G

round P

oin

t

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

CR

8

Warn

ing

, The s

tain

less

ste

el encl

osu

res

are

fitted w

ith s

traps

to e

nsu

re that th

e lid

is

at th

e

sam

e p

ote

ntial as

the e

ncl

osu

re b

ody

. Take

ca

re w

hen r

em

ovi

ng a

nd fitting the e

ncl

osu

re

lids.

Do n

ot re

move

these

str

aps.

The e

xtern

al gro

und

-term

inal of th

e M

PII

stain

less

ste

el encl

osu

res

must

be c

onnect

ed

to g

round in o

rder

to d

issi

pate

any

charg

e

safe

ly a

way

from

the e

ncl

osu

re.

These

tw

o c

able

s sh

ould

be term

inate

d o

nto

the

static

gro

und b

us;

separa

te

but no m

ore

than 1

2"

(300m

m)

apart

.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

Page 11: Earth-Rite® MULTIPOINT II - Redlands

10 11

Ch 1

Ch 2

Ch 3

Ch 4

Ch 5

Ch 6

Ch 7

Ch 8

To M

PII

P

ow

er

Su

pp

ly

Un

it

Ea

rth

-Rite

Mu

ltip

oin

t II

Re

mo

te I

nd

ica

tor

Sta

tion

s

Ea

rth

-Rite

M

ulti

po

int

IIM

ars

ha

llin

g B

ox

Ea

rth-R

ite M

ulti

po

int

II M

on

itorin

g U

nit

1 2 3

4 4 4 4 4 4

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

1 2 3 4

5

Cla

mp

sa

nd

Ca

ble

s

CA

N-

CA

N+

0V

+V

7 8 9

26

10

11 12

13

14

15

16

17

18

19

20

21

22

23

24

Channel S

tatu

sIn

dic

ato

rs(U

nhealth

y)

Watc

h D

og (

Sys

tem

Sta

tus

Indic

ato

r)

4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/ T

AP

E

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

Term

inals

26 a

nd 2

7

are

inte

rnally

connect

ed togeth

er

LR

C1

LR

C2

LR

C3

LR

C4

LR

C5

LR

C6

LR

C7

25 M

ain

LE

D R

etu

rn

LR

C8

Spare

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

To V

erifia

ble

G

round P

oin

t

CR

8

Gro

und T

est

: After

inst

alla

tion a

nd d

uring c

om

mis

sionin

g

tem

pora

rily

dis

connect

the c

able

to term

inal 26/2

7 a

nd

ensu

re that th

e s

yste

m b

eco

mes

non-p

erm

issi

ve.

Channel S

tatu

sIn

dic

ato

rs(H

ealth

y)

Pow

er

Indic

ato

r

1 2 3 4 5 6 7 8

ON

Channel

Sele

ct

Sw

itch

SW

2

1 2 3 4 5 6 7 8

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s –

Us

ing

2-P

ole

Cla

mp

s a

nd

Ca

ble

s a

nd

Re

mo

te I

nd

ica

tor

Sta

tio

ns

1 2 3 4 5 6

Warn

ing

, T

he s

tain

less

ste

el e

ncl

osu

res a

re

fitte

d w

ith s

traps

to e

nsu

re that th

e li

d is a

t th

e

sam

e p

ote

ntia

l as

the e

ncl

osu

re b

ody.

Take

care

when r

em

ovi

ng a

nd fitt

ing the e

nclo

sure

lids. D

o n

ot re

move

these

str

aps

.

The e

xtern

al g

round-

term

inal o

f th

e M

PII

stain

less

ste

el e

ncl

osu

res

must

be c

onnecte

d

to g

round in

ord

er

to d

issi

pate

any

charg

e

safe

ly a

way

from

the e

ncl

osu

re.

These

tw

o c

able

s sh

ould

be term

inate

d o

nto

the

static

gro

und b

us;

separa

te

but no m

ore

than 1

2"

(300m

m) apart

.

www.newson-gale.comwww.newson-gale.com

Ch 1

Ch 2

Ch 3

Ch 4

Ch 5

Ch 6

Ch 7

Ch 8

To

MP

II

Po

we

r S

up

ply

Un

it

Junct

ion

Boxe

s

Eart

h-R

ite

Multi

poin

t II

Mars

halli

ng B

ox

Ea

rth

-Rite

Mu

ltip

oin

t II

Mo

nito

rin

g U

nit

1 2 3

4 4 4 4 4 4

Cla

mps

and C

able

s

CA

N-

CA

N+

0V

+V

26

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s–

Us

ing

2-P

ole

Cla

mp

s a

nd

Ca

ble

s

4 5 6 7 8 9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

1 2 3 4 5 6 7 8

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/T

AP

E

1 4 7 13

16

19

22

10

Watc

h D

og (

Sys

tem

S

tatu

s In

dic

ato

r)

Channel S

tatu

sIn

dic

ato

rs(H

ealthy)

Pow

er

Indic

ato

r

Channel S

tatu

sIn

dic

ato

rs(U

nhealthy)

1 2 3 4 5 6 7 8

O N

Channel

Sele

ct

Sw

itch

SW

2

Term

inals

26 a

nd 2

7

are

inte

rnally

co

nnect

ed togeth

er

Gro

und T

est

: A

fter

inst

alla

tion a

nd d

uring c

om

mis

sio

nin

g

tem

pora

rily

dis

connect

the c

able

to term

inal 26/

27 a

nd

ensu

re that th

e s

yste

m b

eco

mes n

on-p

erm

issiv

e.

To V

erifia

ble

G

round P

oin

t

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

CR

8

Warn

ing

, The s

tain

less

ste

el encl

osu

res

are

fitted w

ith s

traps

to e

nsu

re that th

e lid

is

at th

e

sam

e p

ote

ntial as

the e

ncl

osu

re b

ody

. Take

ca

re w

hen r

em

ovi

ng a

nd fitting the e

ncl

osu

re

lids.

Do n

ot re

move

these

str

aps.

The e

xtern

al gro

und

-term

inal of th

e M

PII

stain

less

ste

el encl

osu

res

must

be c

onnect

ed

to g

round in o

rder

to d

issi

pate

any

charg

e

safe

ly a

way

from

the e

ncl

osu

re.

These

tw

o c

able

s sh

ould

be term

inate

d o

nto

the

static

gro

und b

us;

separa

te

but no m

ore

than 1

2"

(300m

m)

apart

.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

Page 12: Earth-Rite® MULTIPOINT II - Redlands

12 13

To M

onito

ring

Unit

120V

240V

NL

2

MA

INS

SU

PP

LY T

ER

MIN

AL

S

+V 0V C+ C-

PL2

N/C

N/O

C C

H1

N/C

N/O

C C

H2

N/C

N/O

C C

H3

N/C

N/O

C C

H4

N/C

N/O

C C

H5

N/C

N/O

C C

H6

N/C

N/O

C C

H7

N/C

N/O

C C

H8

N/C

N/O

C G

R1

N/C

N/O

C G

R2

N/C

N/O

C F

LT

Inte

rlock

Conta

cts

(1 c

hange

-ove

r co

nta

ct p

er

Channel)

Gro

up Inte

rlock

Conta

cts

(2 c

hange

-ove

r co

nta

cts

)

Fault

Conta

cts

(1 c

ha

ng

e-o

ver

con

tact

)

Supply

(Lin

e)

Term

inals

120

/240

V 5

0/6

0H

z

Ea

rth-R

ite

Mu

ltip

oin

t II

Po

we

r S

up

ply

Un

it

ON

SW

2

GROUP

SELECT

Note

: T

he tig

hte

nin

g torq

ue for

the g

reen E

x e term

inals

is

0.4

Nm

min

imum

to 0

.5 N

m m

axi

mum

.

Equip

ment G

roundin

g

Conduct

or

Term

inals

Gro

up

Sele

ct

Sw

itch

RLY

1

RLY

2

RLY

3

RLY

4

RLY

5

RLY

6

RLY

7

RLY

8

RLY

9

RLY

10

RLY

11

1 2 3 4 5 6 7 8

ON

www.newson-gale.comwww.newson-gale.com

Ch

1

Ch

2

Ch

3

Ch

4

Ch

5

Ch

6

Ch

7

Ch

8To

MP

II

Po

we

r S

up

ply

Un

it

Ea

rth

-Rite

M

ulti

po

int

IIM

ars

ha

llin

g B

ox

1 2 3

4 4 4 4 4 4

Sin

gle

Po

le

Co

nn

ect

ion

s

CA

N-

CA

N+

0V

+V

1 4 7

26

13

16

19

22

4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/T

AP

E

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

10

1 2 3 4 5 6 7 8

Re

fere

nce

Gro

un

d C

ab

le

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s–

Us

ing

Sin

gle

-Po

le C

on

ne

cti

on

s a

nd

Ca

ble

s

Wa

tch

Do

g (

Sys

tem

S

tatu

s In

dic

ato

r)

Ch

an

ne

l Sta

tus

Ind

ica

tors

(He

alth

y)

Po

we

r In

dic

ato

r

Ch

an

ne

l S

tatu

sIn

dic

ato

rs(U

nh

ea

lth

y)

1 2 3 4 5 6 7 8

ON

Ch

an

ne

l S

ele

ct

Sw

itch

SW

2

Ea

rth-R

ite M

ulti

po

int

II M

on

ito

rin

g U

nit

Term

ina

ls 2

6 a

nd

27

a

re in

tern

ally

co

nn

ect

ed

to

ge

the

r

Gro

un

d T

est

: A

fte

r in

sta

llatio

n a

nd

du

rin

g c

om

mis

sio

nin

g

tem

po

rarily

dis

con

ne

ct t

he

ca

ble

to

te

rmin

al 26/2

7 a

nd

e

nsu

re t

ha

t th

e s

yste

m b

eco

me

s n

on-p

erm

issiv

e.

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

CR

8

Th

ese

tw

o c

ab

les

sho

uld

b

e t

erm

ina

ted

on

to t

he

st

atic

gro

un

d b

us; s

ep

ara

te

bu

t n

o m

ore

th

an

12

" (3

00m

m)

ap

art

.

Wa

rnin

g, T

he

sta

inle

ss s

tee

l e

nclo

su

res a

re

fitt

ed

with

str

ap

s t

o e

nsu

re t

ha

t th

e lid

is a

t th

e

sa

me

po

ten

tia

l a

s t

he

en

clo

su

re b

od

y. T

ake

ca

re w

he

n r

em

ovin

g a

nd

fittin

g t

he

en

clo

su

re

lids.

Do

no

t re

mo

ve

th

ese

str

ap

s.

Th

e e

xte

rna

l g

rou

nd-

term

ina

l o

f th

e M

PII

sta

inle

ss s

tee

l e

nclo

su

res m

ust

be

co

nn

ecte

d

to g

rou

nd

in

ord

er

to d

issip

ate

an

y c

ha

rge

sa

fely

aw

ay f

rom

th

e e

nclo

su

re.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

Page 13: Earth-Rite® MULTIPOINT II - Redlands

12 13

To M

onito

ring

Unit

120V

240V

NL

2

MA

INS

SU

PP

LY T

ER

MIN

AL

S

+V 0V C+ C-

PL2

N/C

N/O

C C

H1

N/C

N/O

C C

H2

N/C

N/O

C C

H3

N/C

N/O

C C

H4

N/C

N/O

C C

H5

N/C

N/O

C C

H6

N/C

N/O

C C

H7

N/C

N/O

C C

H8

N/C

N/O

C G

R1

N/C

N/O

C G

R2

N/C

N/O

C F

LT

Inte

rlock

Conta

cts

(1 c

hange

-ove

r co

nta

ct p

er

Channel)

Gro

up Inte

rlock

Conta

cts

(2 c

hange

-ove

r co

nta

cts

)

Fault

Conta

cts

(1 c

ha

ng

e-o

ver

con

tact

)

Supply

(Lin

e)

Term

inals

120

/240

V 5

0/6

0H

z

Ea

rth-R

ite

Mu

ltip

oin

t II

Po

we

r S

up

ply

Un

it

ON

SW

2

GROUP

SELECT

Note

: T

he tig

hte

nin

g torq

ue for

the g

reen E

x e term

inals

is

0.4

Nm

min

imum

to 0

.5 N

m m

axi

mum

.

Equip

ment G

roundin

g

Conduct

or

Term

inals

Gro

up

Sele

ct

Sw

itch

RLY

1

RLY

2

RLY

3

RLY

4

RLY

5

RLY

6

RLY

7

RLY

8

RLY

9

RLY

10

RLY

11

1 2 3 4 5 6 7 8

ON

www.newson-gale.comwww.newson-gale.com

Ch

1

Ch

2

Ch

3

Ch

4

Ch

5

Ch

6

Ch

7

Ch

8To

MP

II

Po

we

r S

up

ply

Un

it

Ea

rth

-Rite

M

ulti

po

int

IIM

ars

ha

llin

g B

ox

1 2 3

4 4 4 4 4 4

Sin

gle

Po

le

Co

nn

ect

ion

s

CA

N-

CA

N+

0V

+V

1 4 7

26

13

16

19

22

4 5 6 7 8 9 10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

27

CU

ST

OM

ER

’S S

TA

TIC

GR

OU

ND

BU

S/T

AP

E

VE

RIF

IAB

LE

STA

TIC

G

RO

UN

D P

OIN

T

10

1 2 3 4 5 6 7 8

Re

fere

nce

Gro

un

d C

ab

le

Ea

rth

-Rit

e M

ult

ipo

int

II –

Ty

pic

al

Mo

nit

ori

ng

Un

it C

on

ne

cti

on

s–

Us

ing

Sin

gle

-Po

le C

on

ne

cti

on

s a

nd

Ca

ble

s

Wa

tch

Do

g (

Sys

tem

S

tatu

s In

dic

ato

r)

Ch

an

ne

l Sta

tus

Ind

ica

tors

(He

alth

y)

Po

we

r In

dic

ato

r

Ch

an

ne

l S

tatu

sIn

dic

ato

rs(U

nh

ea

lth

y)

1 2 3 4 5 6 7 8

ON

Ch

an

ne

l S

ele

ct

Sw

itch

SW

2

Ea

rth-R

ite M

ulti

po

int

II M

on

ito

rin

g U

nit

Term

ina

ls 2

6 a

nd

27

a

re in

tern

ally

co

nn

ect

ed

to

ge

the

r

Gro

un

d T

est

: A

fte

r in

sta

llatio

n a

nd

du

rin

g c

om

mis

sio

nin

g

tem

po

rarily

dis

con

ne

ct t

he

ca

ble

to

te

rmin

al 26/2

7 a

nd

e

nsu

re t

ha

t th

e s

yste

m b

eco

me

s n

on-p

erm

issiv

e.

CR

1

CR

2

CR

3

CR

4

CR

5

CR

6

CR

7

CR

8

Th

ese

tw

o c

ab

les

sho

uld

b

e t

erm

ina

ted

on

to t

he

st

atic

gro

un

d b

us; s

ep

ara

te

bu

t n

o m

ore

th

an

12

" (3

00m

m)

ap

art

.

Wa

rnin

g, T

he

sta

inle

ss s

tee

l e

nclo

su

res a

re

fitt

ed

with

str

ap

s t

o e

nsu

re t

ha

t th

e lid

is a

t th

e

sa

me

po

ten

tia

l a

s t

he

en

clo

su

re b

od

y. T

ake

ca

re w

he

n r

em

ovin

g a

nd

fittin

g t

he

en

clo

su

re

lids.

Do

no

t re

mo

ve

th

ese

str

ap

s.

Th

e e

xte

rna

l g

rou

nd-

term

ina

l o

f th

e M

PII

sta

inle

ss s

tee

l e

nclo

su

res m

ust

be

co

nn

ecte

d

to g

rou

nd

in

ord

er

to d

issip

ate

an

y c

ha

rge

sa

fely

aw

ay f

rom

th

e e

nclo

su

re.

* T

hese

sh

ort

co

nn

ectio

n

cab

les

are

inclu

ded

.

Page 14: Earth-Rite® MULTIPOINT II - Redlands

14 15

Group Relays

Group Relay contacts

Example: Group Relays are configured to operate when Channels 2 AND 3 AND 5 are permissive.

At this point in time Channels 2, 3 and 5 are not permissive so the Group Relays are not energised.

At this point in time Channels 2, 3 and 5 are permissive so the Group Relays are energised.

At this point in time Channels 2 and 5 are permissive but

channel 3 is not permissive.

This results in the Group Relays being de-energised.

All selected channels have to be permissive in order to

energise the Group Relays.

RLY

10

RL

Y9

RLY10

RLY9

RLY

10

RL

Y9

RLY10

RLY9

Ch2 Ch3 Ch5

Ch2 Ch3 Ch5

RL

Y1

0R

LY

9

RLY10

RLY9

Ch2 Ch3 Ch5

1

2

3

Examples

To energise the Group Relays when Channel 1 becomes permissive: Move switch 1 to the ON position.This will cause the Group Relays to energise when Channel 1 becomes permissive.

To energise the Group Relays when Channel 3 becomes permissive: Move switch 3 to the ON position.

Move switches 2, 3 and 5 to the ON position.

Move switches 2 and 3 to the ON position.

To energise the Group Relays when Channels 2 AND 3 AND 5 become permissive:

To energise the Group Relays when Channels 2 AND 3 become permissive:

This will cause the Group Relays to energise when Channels 2 AND 3 AND 5 become permissive.

This will cause the Group Relays to energise when Channel 3 becomes permissive.

This will cause the Group Relays to energise when Channels 2 AND 3 become permissive.

Channels 2 AND 3 AND 5 have to be permissive for the Group Relays to energise. If either Channel 2 or Channel 3 or Channel 5 becomes non-permissive the Group Relays will de-energise. Please refer to Fig.1.

Channels 2 AND 3 have to be permissive for the Group Relays to energise. If either Channel 2 or Channel 3 becomes non-permissive the Group Relays will de-energise.

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

SW2

The Group Relays operate as a pair, in unison, to provide two sets of changeover contacts.

Group Select DIP-Switch (SW2) comprises 8 switches which are used to select which Channel, or Channels, cause the Group Relays to energise.

Earth-Rite MULTIPOINT II has a Group Relay facility which allows additional relays (RLY9 and RL10) to energise when one or more channels become permissive. This feature is useful for controlling common remote circuits such as strobe lights, sounders etc., and for interfacing with a computer or PLC.

In other-words, Relay 9 (RLY9) will always switch at the same time as Relay 10 (RLY10).

Setting The Group Relays – Power Supply Unit Fig. 1 - Illustration example Group Relay control

www.newson-gale.comwww.newson-gale.com

Page 15: Earth-Rite® MULTIPOINT II - Redlands

14 15

Group Relays

Group Relay contacts

Example: Group Relays are configured to operate when Channels 2 AND 3 AND 5 are permissive.

At this point in time Channels 2, 3 and 5 are not permissive so the Group Relays are not energised.

At this point in time Channels 2, 3 and 5 are permissive so the Group Relays are energised.

At this point in time Channels 2 and 5 are permissive but

channel 3 is not permissive.

This results in the Group Relays being de-energised.

All selected channels have to be permissive in order to

energise the Group Relays.

RLY

10

RL

Y9

RLY10

RLY9

RLY

10

RL

Y9

RLY10

RLY9

Ch2 Ch3 Ch5

Ch2 Ch3 Ch5

RL

Y1

0R

LY

9

RLY10

RLY9

Ch2 Ch3 Ch5

1

2

3

Examples

To energise the Group Relays when Channel 1 becomes permissive: Move switch 1 to the ON position.This will cause the Group Relays to energise when Channel 1 becomes permissive.

To energise the Group Relays when Channel 3 becomes permissive: Move switch 3 to the ON position.

Move switches 2, 3 and 5 to the ON position.

Move switches 2 and 3 to the ON position.

To energise the Group Relays when Channels 2 AND 3 AND 5 become permissive:

To energise the Group Relays when Channels 2 AND 3 become permissive:

This will cause the Group Relays to energise when Channels 2 AND 3 AND 5 become permissive.

This will cause the Group Relays to energise when Channel 3 becomes permissive.

This will cause the Group Relays to energise when Channels 2 AND 3 become permissive.

Channels 2 AND 3 AND 5 have to be permissive for the Group Relays to energise. If either Channel 2 or Channel 3 or Channel 5 becomes non-permissive the Group Relays will de-energise. Please refer to Fig.1.

Channels 2 AND 3 have to be permissive for the Group Relays to energise. If either Channel 2 or Channel 3 becomes non-permissive the Group Relays will de-energise.

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

SW2

The Group Relays operate as a pair, in unison, to provide two sets of changeover contacts.

Group Select DIP-Switch (SW2) comprises 8 switches which are used to select which Channel, or Channels, cause the Group Relays to energise.

Earth-Rite MULTIPOINT II has a Group Relay facility which allows additional relays (RLY9 and RL10) to energise when one or more channels become permissive. This feature is useful for controlling common remote circuits such as strobe lights, sounders etc., and for interfacing with a computer or PLC.

In other-words, Relay 9 (RLY9) will always switch at the same time as Relay 10 (RLY10).

Setting The Group Relays – Power Supply Unit Fig. 1 - Illustration example Group Relay control

www.newson-gale.comwww.newson-gale.com

Page 16: Earth-Rite® MULTIPOINT II - Redlands

16 17

To activate all Channels (1 to 8):

This will activate all Channels (1 to 8). Move all switches (1 to 8) to the ON position.

This will activate Channels 1 to 5 only.

To activate Channels 1 to 5:

The LEDs for channels 1 to 5 will function (Red/Green depending on channel status).

The LEDs for all channels will function (Red/Green depending on channel status).

Examples

Move switches 1, 2, 3, 4 and 5 to the ON position.

The LEDs for the other channels will not show.

To activate Channels 1 to 3: Move switches 1, 2, and 3 to the ON position.

The LEDs for the other channels will not show.

NoteEach active Monitoring Unit Channel controls its own relay within the Earth-Rite MULTIPOINT II Power Supply Unit.Channel 1 controls Relay RLY1, Channel 2 controls Relay RLY2 etc.

This will activate Channels 1 to 3 only. The LEDs for channels 1 to 3 will function (Red/Green depending on channel status).

Channel Select DIP-Switch (SW2) comprises 8 switches which are used to select the channels.

Setting The Active Channels – Monitoring Unit

Earth-Rite MULTIPOINT II has a Channel Select facility which allows the installer to select which channels are active and which are inactive.

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

SW2

Using The Fault Relay Contacts - FLT

Earth-Rite MULTIPOINT II has a Fault-Relay facility which allows relay RLY11 to switch when the system encounters a communication fault. This feature is useful for alerting operators and supervisors in the unlikely event of a system fault.

The fault-relay contact status, with respect to the system condition, is shown in the table below.

Fault-Relay RLY11 Contact Status

nc

c

no

nc

c

no

nc

c

no

FLT

FLT

FLT

Condition Status

Power to Earth-Rite MULTIPOINT II is OFF

Power to Earth-Rite MULTIPOINT II is ON and system is communicating correctly

Power to Earth-Rite MULTIPOINT II is ON and system has a communication fault

www.newson-gale.comwww.newson-gale.com

Page 17: Earth-Rite® MULTIPOINT II - Redlands

16 17

To activate all Channels (1 to 8):

This will activate all Channels (1 to 8). Move all switches (1 to 8) to the ON position.

This will activate Channels 1 to 5 only.

To activate Channels 1 to 5:

The LEDs for channels 1 to 5 will function (Red/Green depending on channel status).

The LEDs for all channels will function (Red/Green depending on channel status).

Examples

Move switches 1, 2, 3, 4 and 5 to the ON position.

The LEDs for the other channels will not show.

To activate Channels 1 to 3: Move switches 1, 2, and 3 to the ON position.

The LEDs for the other channels will not show.

NoteEach active Monitoring Unit Channel controls its own relay within the Earth-Rite MULTIPOINT II Power Supply Unit.Channel 1 controls Relay RLY1, Channel 2 controls Relay RLY2 etc.

This will activate Channels 1 to 3 only. The LEDs for channels 1 to 3 will function (Red/Green depending on channel status).

Channel Select DIP-Switch (SW2) comprises 8 switches which are used to select the channels.

Setting The Active Channels – Monitoring Unit

Earth-Rite MULTIPOINT II has a Channel Select facility which allows the installer to select which channels are active and which are inactive.

12

34

56

78

ON

12

34

56

78

ON

12

34

56

78

ON

SW2

Using The Fault Relay Contacts - FLT

Earth-Rite MULTIPOINT II has a Fault-Relay facility which allows relay RLY11 to switch when the system encounters a communication fault. This feature is useful for alerting operators and supervisors in the unlikely event of a system fault.

The fault-relay contact status, with respect to the system condition, is shown in the table below.

Fault-Relay RLY11 Contact Status

nc

c

no

nc

c

no

nc

c

no

FLT

FLT

FLT

Condition Status

Power to Earth-Rite MULTIPOINT II is OFF

Power to Earth-Rite MULTIPOINT II is ON and system is communicating correctly

Power to Earth-Rite MULTIPOINT II is ON and system has a communication fault

www.newson-gale.comwww.newson-gale.com

Page 18: Earth-Rite® MULTIPOINT II - Redlands

18 19

Verifiable Earthing/Grounding Point

4-way Marshalling Box - Terminal Utilisation DetailEarth-Rite MULTIPOINT II8-way Marshalling Box - Terminal Utilisation DetailEarth-Rite MULTIPOINT II

Verifiable Earthing/Grounding Point

www.newson-gale.comwww.newson-gale.com

* These short connection cables

are included.

* These short connection cables

are included.

Page 19: Earth-Rite® MULTIPOINT II - Redlands

18 19

Verifiable Earthing/Grounding Point

4-way Marshalling Box - Terminal Utilisation DetailEarth-Rite MULTIPOINT II8-way Marshalling Box - Terminal Utilisation DetailEarth-Rite MULTIPOINT II

Verifiable Earthing/Grounding Point

www.newson-gale.comwww.newson-gale.com

* These short connection cables

are included.

* These short connection cables

are included.

Page 20: Earth-Rite® MULTIPOINT II - Redlands

20 21

The Red LEDs will show whenever the Ground Loop resistance is too high.

Note: “no” refers to the normally-open contact and “c” refers to the common contact.

Note: The Grounding Clamp should be fitted prior to any other operation.

B. Attach the Grounding Clamp onto the conductive plant item at a suitable point and ensure that the pointed contacts are positively located.

If the connection to the plant item and Ground is good, then the Green Positive Ground Condition LED will show and the c-no output contacts will close.

Note: The green LED in the Junction Box flashes but the green LED in the Monitoring Unit is steady.The product transfer / mixing operation can now take place.

C. If the connection between the plant item and Ground is broken during the transfer operation, then the Green Positive Ground Condition LED will switch off and the c-no output contacts will open.

A. In the normal "rest" state, with the Grounding Clamp stowed on the insulated pin, the Green Positive Ground Condition LED will be switched off and the c-no output contacts will be open.

D. On completion the Grounding Clamp should be removed from the plant item and stowed on the insulated pin on the front of the Remote Indicator Station. The Green Positive Ground Condition LED will switch off and the c-no output contacts will open.

Earth-Rite MULTIPOINT II - Typical Operation

Monitoring UnitRemote Indicator

Station

Clamp

Drum

Important NoteThe grounding clamp should be fitted prior to any other operation as per the recommendations of IEC TS 60079-32-1, CLC/TR: 60079-32-1, NFPA 77 and API RP 2003

by certificate numbered CSA 15.70005381.

The equipment contains no user-replaceable parts.

The Monitor Unit may be used in Canada/USA: Class I, Div. 1, Groups A, B, C, D, Class I, Zone 0, Group IIC; Class II, Div. 1, Groups E, F, G; Class II, Zone 20, Group IIIC, Class III, Div. 1.

used outside this range.

Regular periodic inspection of the equipment should be performed by suitably trained personnel in

The following instructions apply to the Earth-Rite Earth-Rite MULTIPOINT II Earth Monitoring Module, coveredUser instructions

o oThe equipment is certified for use in ambient temperatures in the range of –40 C to +60 C and should not be

The equipment is to be installed by suitably trained personnel in accordance with the applicable code of

The equipment is not intended to be repaired by the user. Repair of the equipment is to be carried out by the

practice.

manufacturer, or their approved agents, in accordance with the applicable code of practice.

The PSU may be used in Canada/USA: Class I, Div. 2, Groups A, B, C, D; Class I, Zone 2, Group IIC; Class II, Div. 1,Groups E,F, G; Class III, Div. 1; Class II, Zone 21, Group IIIC or Unclassified Location.

No user adjustment is required.

Instructions for safe selection, installation, use, maintenance and repair

accordance with the applicable code of practice to ensure it is maintained in a satisfactory condition.

Special Conditions for Safe Use: The system shall be installed as per the control drawing X MPII Q15152 cCSAus.

Before using the Earth-Rite MULTIPOINT II each day it is important to check the operation to ensure that the LEDs switch on and off as expected. This is particularly important if the Earth-Rite MULTIPOINT II is used to monitor fixed connections.

The Earth-Rite MULTIPOINT II should be used by trained, competent persons only.

Omega House, Private Road 8Colwick, Nottingham - NG4 2JX - UK

Tel: +44 (0)115 940 7500 Fax: +44 (0)115 940 7501

Web: www.newson-gale.comEmail: [email protected]

www.newson-gale.comwww.newson-gale.com

Page 21: Earth-Rite® MULTIPOINT II - Redlands

20 21

The Red LEDs will show whenever the Ground Loop resistance is too high.

Note: “no” refers to the normally-open contact and “c” refers to the common contact.

Note: The Grounding Clamp should be fitted prior to any other operation.

B. Attach the Grounding Clamp onto the conductive plant item at a suitable point and ensure that the pointed contacts are positively located.

If the connection to the plant item and Ground is good, then the Green Positive Ground Condition LED will show and the c-no output contacts will close.

Note: The green LED in the Junction Box flashes but the green LED in the Monitoring Unit is steady.The product transfer / mixing operation can now take place.

C. If the connection between the plant item and Ground is broken during the transfer operation, then the Green Positive Ground Condition LED will switch off and the c-no output contacts will open.

A. In the normal "rest" state, with the Grounding Clamp stowed on the insulated pin, the Green Positive Ground Condition LED will be switched off and the c-no output contacts will be open.

D. On completion the Grounding Clamp should be removed from the plant item and stowed on the insulated pin on the front of the Remote Indicator Station. The Green Positive Ground Condition LED will switch off and the c-no output contacts will open.

Earth-Rite MULTIPOINT II - Typical Operation

Monitoring UnitRemote Indicator

Station

Clamp

Drum

Important NoteThe grounding clamp should be fitted prior to any other operation as per the recommendations of IEC TS 60079-32-1, CLC/TR: 60079-32-1, NFPA 77 and API RP 2003

by certificate numbered CSA 15.70005381.

The equipment contains no user-replaceable parts.

The Monitor Unit may be used in Canada/USA: Class I, Div. 1, Groups A, B, C, D, Class I, Zone 0, Group IIC; Class II, Div. 1, Groups E, F, G; Class II, Zone 20, Group IIIC, Class III, Div. 1.

used outside this range.

Regular periodic inspection of the equipment should be performed by suitably trained personnel in

The following instructions apply to the Earth-Rite Earth-Rite MULTIPOINT II Earth Monitoring Module, coveredUser instructions

o oThe equipment is certified for use in ambient temperatures in the range of –40 C to +60 C and should not be

The equipment is to be installed by suitably trained personnel in accordance with the applicable code of

The equipment is not intended to be repaired by the user. Repair of the equipment is to be carried out by the

practice.

manufacturer, or their approved agents, in accordance with the applicable code of practice.

The PSU may be used in Canada/USA: Class I, Div. 2, Groups A, B, C, D; Class I, Zone 2, Group IIC; Class II, Div. 1,Groups E,F, G; Class III, Div. 1; Class II, Zone 21, Group IIIC or Unclassified Location.

No user adjustment is required.

Instructions for safe selection, installation, use, maintenance and repair

accordance with the applicable code of practice to ensure it is maintained in a satisfactory condition.

Special Conditions for Safe Use: The system shall be installed as per the control drawing X MPII Q15152 cCSAus.

Before using the Earth-Rite MULTIPOINT II each day it is important to check the operation to ensure that the LEDs switch on and off as expected. This is particularly important if the Earth-Rite MULTIPOINT II is used to monitor fixed connections.

The Earth-Rite MULTIPOINT II should be used by trained, competent persons only.

Omega House, Private Road 8Colwick, Nottingham - NG4 2JX - UK

Tel: +44 (0)115 940 7500 Fax: +44 (0)115 940 7501

Web: www.newson-gale.comEmail: [email protected]

www.newson-gale.comwww.newson-gale.com

Page 22: Earth-Rite® MULTIPOINT II - Redlands

22 23

Marking Details for Power Supply UnitEarth-Rite MULTIPOINT IIMarking Details for Monitoring UnitEarth-Rite MULTIPOINT II

Canada:Ex ia IIC T4 GaEx ia IIIC T135°C Da

USA:Class I, Zone 0, AEx ia IIC T4 GaClass II, Zone 20, AEx ia IIIC T135°C Da

T4@ Ta = -40oC to +60oC

Warning: Explosion Hazard – Substitution of components may impair suitability for use in a

hazardous location

AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS PRUT COMPROMETTRE LA

SÉCURITÉ INTRINSÈQUE

Enclosure Type 4X, IP66

Canada/USA:Intrinsically Safe Equipment Exia for use in

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

CSA 15.70005381

Earth-Rite Multipoint II

Nottingham, NG4 2JX UK

This equipment shall be powered only from the

Newson Gale Multipoint II power supply

Earth-Rite Multipoint II

www.newson-gale.com

Serial No. YY/xxxxxProduct Code : ??????

SEE SUPPLEMENTARY LABEL FOR

PRODUCT CODE, SERIAL NUMBER AND YEAR OF MANUFACTURE

Static Earthing System

Monitoring Unit

Vmax/Ui = 11.76V, Imax/Ii = 0.413A, Pi = 0.904W, Ci = 1.3μF, Li = 0, Uo/Voc = 11.76V, Io/Isc = 0.170A, Po = 500mW, Ci = 0, Li = 208μH,

Co/Ca = 1.5μF, Lo/La = 1022μH, Lo/Ro = 68μH/Ω; when installed as per the control drawing

X MPII Q15152 cCSAus

HAZARDOUS LIVE PARTS –DO NOT OPEN THE ENCLOSURE

WHILE ENERGISED

Warning: Explosion Hazard – Substitution of components may impair suitability for use in a

hazardous location

AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS PRUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE

Warning: Explosion Hazard – Do not disconnect

equipment unless power has been switched off or

the area is known to be non-hazardous

Relay contact maximum resistive ratings: 250Vac, 5A, 500VA; 30Vdc, 2A, 60W

Avertissement : Danger d’explosion – Ne pas débrancher l’équipement s’il n’a pas été mis hors

tension ou si la zone est réputée être dangereuse

PIÈCES SOUS TENSION DANGEREUSES – NE PAS OUVRIR LE BOÎTIER QUAND IL EST SOUS

TENSION

T4@ Ta = -40oC to +60oC

CSA 15.70005381

Serial No. YY/xxxxx

Earth-Rite Multipoint II

www.newson-gale.com

Static Earthing System

Supply Voltage: 220-240V50/60Hz, 200mA110-120V50/60Hz, 200mA

Product Code: ???????

Nottingham, NG4 2JX UK

SEE SUPPLEMENTARY LABEL FOR MODEL

NUMBER,PRODUCT CODE, SERIAL NUMBER

AND YEAR OF MANUFACTURE

Power Supply Unit

Input Ratings:120/240Vac, 50/60Hz, 200mA

Model Number : ???????

Enclosure Type 4X, IP66 (GRP)Enclosure Type 4X, IP66 (Stainless Steel)

Canada/USA: Suitable for use In Class I, Div. 2,

Groups A, B, C, D; Class I, Zone 2, Group IIC; Class

II, Div. 1, Groups E, F, G; Class III, Div. 1; Class II, Zone 21, Group IIIC;

Provides intrinsically safe output for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G;

Class III, Div. 1; Class I, Zone 0, Group IIC; Class II,

Zone 20; with entity parameters of : Voc/Uo = 11.76V, Isc/Io = 0.413A, Po = 0.904W, Ca/Co = 1.5μF, La/Lo =

208μH, Lo/Ro = 29.1μH/Ω; when installed as per the control drawing ‘X MPII Q15152’

Um = 250V

Canada: Class I, Div2, Groups A , B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Ex nA[ia Ga] nC IIC T4 Gc

Ex tb IIIC T65ºC Db

USA: Class I, Div2, Groups A, B, C,D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 2, AEx nA[ia Ga] nC IIC T4 Gc

Class II, Zone 21, AEx tb IIIC T65ºC Db

www.newson-gale.comwww.newson-gale.com

Page 23: Earth-Rite® MULTIPOINT II - Redlands

22 23

Marking Details for Power Supply UnitEarth-Rite MULTIPOINT IIMarking Details for Monitoring UnitEarth-Rite MULTIPOINT II

Canada:Ex ia IIC T4 GaEx ia IIIC T135°C Da

USA:Class I, Zone 0, AEx ia IIC T4 GaClass II, Zone 20, AEx ia IIIC T135°C Da

T4@ Ta = -40oC to +60oC

Warning: Explosion Hazard – Substitution of components may impair suitability for use in a

hazardous location

AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS PRUT COMPROMETTRE LA

SÉCURITÉ INTRINSÈQUE

Enclosure Type 4X, IP66

Canada/USA:Intrinsically Safe Equipment Exia for use in

Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

CSA 15.70005381

Earth-Rite Multipoint II

Nottingham, NG4 2JX UK

This equipment shall be powered only from the

Newson Gale Multipoint II power supply

Earth-Rite Multipoint II

www.newson-gale.com

Serial No. YY/xxxxxProduct Code : ??????

SEE SUPPLEMENTARY LABEL FOR

PRODUCT CODE, SERIAL NUMBER AND YEAR OF MANUFACTURE

Static Earthing System

Monitoring Unit

Vmax/Ui = 11.76V, Imax/Ii = 0.413A, Pi = 0.904W, Ci = 1.3μF, Li = 0, Uo/Voc = 11.76V, Io/Isc = 0.170A, Po = 500mW, Ci = 0, Li = 208μH,

Co/Ca = 1.5μF, Lo/La = 1022μH, Lo/Ro = 68μH/Ω; when installed as per the control drawing

X MPII Q15152 cCSAus

HAZARDOUS LIVE PARTS –DO NOT OPEN THE ENCLOSURE

WHILE ENERGISED

Warning: Explosion Hazard – Substitution of components may impair suitability for use in a

hazardous location

AVERTISSEMENT : LA SUBSTITUTION DE COMPOSANTS PRUT COMPROMETTRE LA SÉCURITÉ INTRINSÈQUE

Warning: Explosion Hazard – Do not disconnect

equipment unless power has been switched off or

the area is known to be non-hazardous

Relay contact maximum resistive ratings: 250Vac, 5A, 500VA; 30Vdc, 2A, 60W

Avertissement : Danger d’explosion – Ne pas débrancher l’équipement s’il n’a pas été mis hors

tension ou si la zone est réputée être dangereuse

PIÈCES SOUS TENSION DANGEREUSES – NE PAS OUVRIR LE BOÎTIER QUAND IL EST SOUS

TENSION

T4@ Ta = -40oC to +60oC

CSA 15.70005381

Serial No. YY/xxxxx

Earth-Rite Multipoint II

www.newson-gale.com

Static Earthing System

Supply Voltage: 220-240V50/60Hz, 200mA110-120V50/60Hz, 200mA

Product Code: ???????

Nottingham, NG4 2JX UK

SEE SUPPLEMENTARY LABEL FOR MODEL

NUMBER,PRODUCT CODE, SERIAL NUMBER

AND YEAR OF MANUFACTURE

Power Supply Unit

Input Ratings:120/240Vac, 50/60Hz, 200mA

Model Number : ???????

Enclosure Type 4X, IP66 (GRP)Enclosure Type 4X, IP66 (Stainless Steel)

Canada/USA: Suitable for use In Class I, Div. 2,

Groups A, B, C, D; Class I, Zone 2, Group IIC; Class

II, Div. 1, Groups E, F, G; Class III, Div. 1; Class II, Zone 21, Group IIIC;

Provides intrinsically safe output for Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G;

Class III, Div. 1; Class I, Zone 0, Group IIC; Class II,

Zone 20; with entity parameters of : Voc/Uo = 11.76V, Isc/Io = 0.413A, Po = 0.904W, Ca/Co = 1.5μF, La/Lo =

208μH, Lo/Ro = 29.1μH/Ω; when installed as per the control drawing ‘X MPII Q15152’

Um = 250V

Canada: Class I, Div2, Groups A , B, C, D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Ex nA[ia Ga] nC IIC T4 Gc

Ex tb IIIC T65ºC Db

USA: Class I, Div2, Groups A, B, C,D; Class II, Div. 1, Groups E, F, G; Class III, Div. 1

Class I, Zone 2, AEx nA[ia Ga] nC IIC T4 Gc

Class II, Zone 21, AEx tb IIIC T65ºC Db

www.newson-gale.comwww.newson-gale.com

Page 24: Earth-Rite® MULTIPOINT II - Redlands

24 25

Earth-Rite MULTIPOINT II Dimensions - Millimetres

AF

B

E

GRP Enclosures

Fixing HoleDiamter - D

Depth - C

B

E

AF

Fixing HoleDiamter - D

Depth - C

Stainless Steel Enclosures

A B C D E F

250

300

300

160

200

161

150

121

150

400

300

300

260

300

161

150

121

150

121

140

140

91

100

93

100

75

100

6.5

10.2

10.2

6.5

10.2

6.5

10.2

6.5

10.2

380

243.5

243.5

240

243.5

140

93.5

100

93.5

200

330

330

110

230

140

178.5

100

178.5

ProductMAIN DIMENSIONS (mm) FIXING DIMENSIONS (mm)

PSU - GRP

PSU - Stainless Steel

Monitoring Unit

8-way Marshalling Box - GRP

8-way Marshalling Box - Stainless Steel

4-way Marshalling Box - GRP

4-way Marshalling Box - Stainless Steel

Remote Indicator Station - GRP

Remote Indicator Station - Stainless Steel

Earth-Rite MULTIPOINT II Dimensions - Inches

AF

B

E

GRP Enclosures

Fixing HoleDiamter - D

Depth - C

B

E

AF

Fixing HoleDiamter - D

Depth - C

Stainless Steel Enclosures

A B C

PSU - GRP

MAIN DIMENSIONS (inches)

D E F

FIXING DIMENSIONS (inches)

PSU - Stainless Steel

Monitoring Unit

8-way Marshalling Box - GRP

8-way Marshalling Box – Stainless Steel

Remote Indicator Station – Stainless Steel

Remote Indicator Station – GRP

4-way Marshalling Box - GRP

4-way Marshalling Box – Stainless Steel

Product

9.8

11.8

11.8

6.3

7.9

6.3

5.9

4.8

5.9

15.7

11.8

11.8

10.2

11.8

6.3

5.9

4.8

5.9

4.8

5.5

5.5

3.6

3.2

3.7

3.2

3

3.2

0.25

0.39

0.39

0.25

0.39

0.25

0.39

0.23

0.39

14.96

9.59

9.59

9.45

9.59

5.51

3.69

3.94

3.69

7.87

12.99

12.99

4.33

10.0

5.51

8.03

3.94

8.03

www.newson-gale.comwww.newson-gale.com

Page 25: Earth-Rite® MULTIPOINT II - Redlands

24 25

Earth-Rite MULTIPOINT II Dimensions - Millimetres

AF

B

E

GRP Enclosures

Fixing HoleDiamter - D

Depth - C

B

E

AF

Fixing HoleDiamter - D

Depth - C

Stainless Steel Enclosures

A B C D E F

250

300

300

160

200

161

150

121

150

400

300

300

260

300

161

150

121

150

121

140

140

91

100

93

100

75

100

6.5

10.2

10.2

6.5

10.2

6.5

10.2

6.5

10.2

380

243.5

243.5

240

243.5

140

93.5

100

93.5

200

330

330

110

230

140

178.5

100

178.5

ProductMAIN DIMENSIONS (mm) FIXING DIMENSIONS (mm)

PSU - GRP

PSU - Stainless Steel

Monitoring Unit

8-way Marshalling Box - GRP

8-way Marshalling Box - Stainless Steel

4-way Marshalling Box - GRP

4-way Marshalling Box - Stainless Steel

Remote Indicator Station - GRP

Remote Indicator Station - Stainless Steel

Earth-Rite MULTIPOINT II Dimensions - Inches

AF

B

E

GRP Enclosures

Fixing HoleDiamter - D

Depth - C

B

E

AF

Fixing HoleDiamter - D

Depth - C

Stainless Steel Enclosures

A B C

PSU - GRP

MAIN DIMENSIONS (inches)

D E F

FIXING DIMENSIONS (inches)

PSU - Stainless Steel

Monitoring Unit

8-way Marshalling Box - GRP

8-way Marshalling Box – Stainless Steel

Remote Indicator Station – Stainless Steel

Remote Indicator Station – GRP

4-way Marshalling Box - GRP

4-way Marshalling Box – Stainless Steel

Product

9.8

11.8

11.8

6.3

7.9

6.3

5.9

4.8

5.9

15.7

11.8

11.8

10.2

11.8

6.3

5.9

4.8

5.9

4.8

5.5

5.5

3.6

3.2

3.7

3.2

3

3.2

0.25

0.39

0.39

0.25

0.39

0.25

0.39

0.23

0.39

14.96

9.59

9.59

9.45

9.59

5.51

3.69

3.94

3.69

7.87

12.99

12.99

4.33

10.0

5.51

8.03

3.94

8.03

www.newson-gale.comwww.newson-gale.com

Page 26: Earth-Rite® MULTIPOINT II - Redlands

26 27www.newson-gale.comwww.newson-gale.com

Page 27: Earth-Rite® MULTIPOINT II - Redlands

26 27www.newson-gale.comwww.newson-gale.com

Page 28: Earth-Rite® MULTIPOINT II - Redlands

28 29

AWG mm2

24 0.20523 0.25922 0.32521 0.41220 0.51919 0.65318 0.82317 1.0416 1.3115 1.6514 2.0813 2.6312 3.3111 4.1510 5.279 6.628 8.35

Awg. Metric

Size Wire

Preferred Size

Sizes mm2

in mm in mm

- 0.5 1/.032 1/.813 0.032 0.81

20 0.519 7/.0121 7/.307 0.036 0.91

- 0.75 1/.039 1/.991 0.039 0.99

18 0.823 1/.0403 1/1.02 0.04 1.02

18 0.823 7/.0152 7/.386 0.046 1.16

18(UL) 1 1/.045 1/1.14 0.045 1.14

18(UL) 1 7/.017 7/.432 0.051 1.3

16 1.31 1/.0508 1/1.29 0.051 1.29

16 1.31 7/.0192 7/.488 0.058 1.46

- 1.5 1/.055 1/1.40 0.055 1.4

- 1.5 7/.021 7/5.33 0.063 1.6

14 2.08 1/.0641 1/1.63 0.064 1.63

14 2.08 7/.0242 7/.615 0.073 1.84

- 2.5 1/.071 1/1.80 0.071 1.8

- 2.5 7/.027 7/.686 0.081 2.06

12 3.31 1/.0808 1/2.05 0.081 2.05

12 3.31 7/.0305 7/.775 0.092 2.32

- 4 1/.089 1/2.26 0.089 2.26

- 4 7/.034 7/.864 0.102 2.59

10 5.27 1/.1019 1/2.59 0.102 2.59

10 5.27 7/.0385 7/.978 0.116 2.93

- 6 1/.109 1/2.77 0.109 2.77

- 6 7/.042 7/1.07 0.126 3.21

9 6.62 1/.1144 1/2.91 0.1144 2.91

9 6.62 7/.0432 7/1.10 0.13 3.3

Approximate

Overall Diameter

Stranding/ Wire

Dia. per Strand

NEMA EnclosureType Number

ApproximateIEC Classification

1

2

3

3R

3S

4 and 4X

5

6 and 6P

IP10

IP11

IP54

IP14

IP54

IP56

IP52

IP67

Length Conversion

LengthUS Imperial

1/8"

1/4"

3/8"

1/2"

3/4"

1"

1¼"

1½"

LengthMetric

3.175mm

6.350mm

10.080mm

12.700mm

19.050mm

25.400mm

31.750mm

38.100mm

1 foot

1 yard

304.8mm

914.4mm

N.P.T.National Pipe Thread to

ANSI/ASME:1983

SizeMajor

Diameter(inches)

Major Diameter

(mm)

1/8" 0.406 10.30

1/4" 0.540 13.72

3/8" 0.689 17.15

1/2" 0.840 21.34

3/4" 1.05 26.67

1" 1.315 33.40

1¼" 1.660 42.16

1½" 1.900 48.26

ISOMETRICISOMetric Thread to

BS3643:1981

SizeMajor

Diameter(inches)

Major Diameter

(mm)

0.63016

0.78720

0.98425

1.26032

M16

M20

M25

M32

CONVERSION TABLESCONVERSION TABLES

Wire Size Comparison Tables Comparison of Enclosure Type Numbers to IEC Classification Designations

Thread Comparison Tables

Length Conversion Table

www.newson-gale.comwww.newson-gale.com

Page 29: Earth-Rite® MULTIPOINT II - Redlands

28 29

AWG mm2

24 0.20523 0.25922 0.32521 0.41220 0.51919 0.65318 0.82317 1.0416 1.3115 1.6514 2.0813 2.6312 3.3111 4.1510 5.279 6.628 8.35

Awg. Metric

Size Wire

Preferred Size

Sizes mm2

in mm in mm

- 0.5 1/.032 1/.813 0.032 0.81

20 0.519 7/.0121 7/.307 0.036 0.91

- 0.75 1/.039 1/.991 0.039 0.99

18 0.823 1/.0403 1/1.02 0.04 1.02

18 0.823 7/.0152 7/.386 0.046 1.16

18(UL) 1 1/.045 1/1.14 0.045 1.14

18(UL) 1 7/.017 7/.432 0.051 1.3

16 1.31 1/.0508 1/1.29 0.051 1.29

16 1.31 7/.0192 7/.488 0.058 1.46

- 1.5 1/.055 1/1.40 0.055 1.4

- 1.5 7/.021 7/5.33 0.063 1.6

14 2.08 1/.0641 1/1.63 0.064 1.63

14 2.08 7/.0242 7/.615 0.073 1.84

- 2.5 1/.071 1/1.80 0.071 1.8

- 2.5 7/.027 7/.686 0.081 2.06

12 3.31 1/.0808 1/2.05 0.081 2.05

12 3.31 7/.0305 7/.775 0.092 2.32

- 4 1/.089 1/2.26 0.089 2.26

- 4 7/.034 7/.864 0.102 2.59

10 5.27 1/.1019 1/2.59 0.102 2.59

10 5.27 7/.0385 7/.978 0.116 2.93

- 6 1/.109 1/2.77 0.109 2.77

- 6 7/.042 7/1.07 0.126 3.21

9 6.62 1/.1144 1/2.91 0.1144 2.91

9 6.62 7/.0432 7/1.10 0.13 3.3

Approximate

Overall Diameter

Stranding/ Wire

Dia. per Strand

NEMA EnclosureType Number

ApproximateIEC Classification

1

2

3

3R

3S

4 and 4X

5

6 and 6P

IP10

IP11

IP54

IP14

IP54

IP56

IP52

IP67

Length Conversion

LengthUS Imperial

1/8"

1/4"

3/8"

1/2"

3/4"

1"

1¼"

1½"

LengthMetric

3.175mm

6.350mm

10.080mm

12.700mm

19.050mm

25.400mm

31.750mm

38.100mm

1 foot

1 yard

304.8mm

914.4mm

N.P.T.National Pipe Thread to

ANSI/ASME:1983

SizeMajor

Diameter(inches)

Major Diameter

(mm)

1/8" 0.406 10.30

1/4" 0.540 13.72

3/8" 0.689 17.15

1/2" 0.840 21.34

3/4" 1.05 26.67

1" 1.315 33.40

1¼" 1.660 42.16

1½" 1.900 48.26

ISOMETRICISOMetric Thread to

BS3643:1981

SizeMajor

Diameter(inches)

Major Diameter

(mm)

0.63016

0.78720

0.98425

1.26032

M16

M20

M25

M32

CONVERSION TABLESCONVERSION TABLES

Wire Size Comparison Tables Comparison of Enclosure Type Numbers to IEC Classification Designations

Thread Comparison Tables

Length Conversion Table

www.newson-gale.comwww.newson-gale.com

Page 30: Earth-Rite® MULTIPOINT II - Redlands

30 31

Earth-Rite MULTIPOINT II System - Technical Specification

Power Supply Unit Specifications

Earth-Rite MULTIPOINT II System - Technical Specification

Monitoring Unit & Accessory Specifications

Class II, Div. 1, Groups E, F, G;

o Class II, Zone 21, AEx tb IIIC T65 C Db

Channel Contact Terminals 24 terminals (normally closed, common, normally open)

Terminal Ratings 250Vac, 5A, 500VA max

Output Relay contact rating 8 voltage free change-over switch contacts (Channel Contacts),

Terminal Type Ex e

12 x 20mm diameter (Stainless Steel Enclosure)

Use For connection to customer’s control and alarm circuits

30Vdc, 2A, 60W max

Use For connection to customer’s Line supply

Terminal Type Ex e

Cable entries 12 x M20 (GRP Enclosure),

External Connection Terminals

Class III, Div. 1.

USA: Class I, Div. 2, Groups A, B, C, D;

1 voltage free change-over switch contact (Alarm Contacts),

250Vac, 5A, 500VA max resistive

Relay Contact Terminals

Group Contact Terminals 6 terminals (normally closed, common, normally open)

Note: NPT threaded adapters are available

Alarm Contact Terminals 3 terminals (normally closed, common, normally open)

Class I, Zone 2, AEx nA[ia Ga] nC IIC T4 Gc.

Terminal Ratings 250Vac, 5A, 500VA max

2 voltage free change-over switch contacts (Group Contacts),

Mains Supply Terminals

30Vdc, 2A, 60W max resistive

Number of Terminals 4 terminals (120V, N, 240V, L2)

Power supply 230/240V 50Hz (Supply voltage range: 216V to 250V)

110/120V 50Hz (Supply voltage range: 108V to 125V)

Current rating 200mA

Class I, Div. 1, Groups A, B, C, D;

Power Supply Unit

Class III, Div. 1;

Class I, Zone 0, Group IIC;

Class II, Zone 20;

Class II, Zone 21, Group IIIC;

Canada: Class I, Div. 2, Groups A, B, C, D;

Class II, Div. 1, Groups E, F, G;

o o o oAmbient temperature range -40 F to +140 F (-40 C to +60 C)

Power rating 10 watt

Canada/USA Class I, Div. 2, Groups A, B, C, D; Class I, Zone 2, Group IIC;

Provides intrinsically safe output for

Construction Static Dissipative Glass-Reinforced Polyester or Stainless Steel

Weight 4.5 kgs (nett)

Class II, Div. 1, Groups E, F, G;

Class III, Div. 1.o Ex nA[ia Ga] nC IIC T4 Gc. Ex tb IIIC T65 C Db.

Certification Suitable for use in

Class III, Div. 1;

Ingress protection IP66

Class II, Div. 1, Groups E, F, G;

Standard Cable entries 3 x 20mm plus 1 x 25mm diameter

6 x 20mm diameter and 1 x 25mm diameter (Stainless Steel Enclosure)

2Terminals 29 x 12AWG (4.00mm ) conductor capacity standard blue terminals

Class II, Div. 1, Groups E, F, G;

2 1 x 10AWG (6.00mm ) conductor capacity ground terminal

Stowage device Insulated pin

o o o oAmbient temperature range -40 F to +140 F (-40 C to +60 C)

Ex ia IIIC T135°C DaUSA: Class I, Zone 0, AEx ia IIC T4 Ga

Weight 4.5 kgs (nett)

2Terminals 5 x 14AWG (2.5mm ) conductor capacity

Construction Stainless Steel housing with polycarbonate window

Monitoring circuit Intrinsically safe

Certification Intrinsically Safe Equipment Exia for use in

8-Way Marshalling Box

Enclosure Type 4X, IP66

Enclosure GRP or Stainless Steel

Class II, Zone 20, AEx ia IIIC T135°C Da

2 1 x 10AWG (6.00mm ) conductor capacity ground terminal

10 x 20mm diameter and 1 x 25mm diameter (Stainless Steel Enclosure)

Note: NPT threaded adapters are available

Canada/USA: Class I, Div. 1, Groups A, B, C, D;

Note: NPT threaded adapters are available

Cable entries 10 x M20 and 1 x M25 (GRP Enclosure)

2) 4 x 12AWG (4.00mm conductor capacity ground terminals

4-Way Marshalling Box

Operational series ground resistance </= 10 Ohm

Enclosure GRP or Stainless Steel

Monitoring Unit

Class III, Div. 1Canada: Ex ia IIC T4 Ga

2Terminals 15 x 12AWG (4.00mm ) conductor capacity standard blue terminals2 2 x 12AWG (4.00mm ) conductor capacity ground terminals

Cable entries 6 x M20 and 1 x M25 (GRP Enclosure)

Note: NPT threaded adapters are available

Remote Indicator Station

Enclosure GRP or Stainless Steel

Cable entry 1 x M20 (GRP Enclosure)

1 x 20mm diamteter (Stainless Steel Enclosure)

NPT threaded adapters are availableNote:

Cable Out Connection Quick Connect

NB: In line with our policy of continual product development, we reserve the right to alter specifications at any time.

Warranty

A two year manufacturer's warranty applies to Newson Gale electronic modules. This is subject to the general terms and conditions and correct installation / usage of the product.

www.newson-gale.comwww.newson-gale.com

Page 31: Earth-Rite® MULTIPOINT II - Redlands

30 31

Earth-Rite MULTIPOINT II System - Technical Specification

Power Supply Unit Specifications

Earth-Rite MULTIPOINT II System - Technical Specification

Monitoring Unit & Accessory Specifications

Class II, Div. 1, Groups E, F, G;

o Class II, Zone 21, AEx tb IIIC T65 C Db

Channel Contact Terminals 24 terminals (normally closed, common, normally open)

Terminal Ratings 250Vac, 5A, 500VA max

Output Relay contact rating 8 voltage free change-over switch contacts (Channel Contacts),

Terminal Type Ex e

12 x 20mm diameter (Stainless Steel Enclosure)

Use For connection to customer’s control and alarm circuits

30Vdc, 2A, 60W max

Use For connection to customer’s Line supply

Terminal Type Ex e

Cable entries 12 x M20 (GRP Enclosure),

External Connection Terminals

Class III, Div. 1.

USA: Class I, Div. 2, Groups A, B, C, D;

1 voltage free change-over switch contact (Alarm Contacts),

250Vac, 5A, 500VA max resistive

Relay Contact Terminals

Group Contact Terminals 6 terminals (normally closed, common, normally open)

Note: NPT threaded adapters are available

Alarm Contact Terminals 3 terminals (normally closed, common, normally open)

Class I, Zone 2, AEx nA[ia Ga] nC IIC T4 Gc.

Terminal Ratings 250Vac, 5A, 500VA max

2 voltage free change-over switch contacts (Group Contacts),

Mains Supply Terminals

30Vdc, 2A, 60W max resistive

Number of Terminals 4 terminals (120V, N, 240V, L2)

Power supply 230/240V 50Hz (Supply voltage range: 216V to 250V)

110/120V 50Hz (Supply voltage range: 108V to 125V)

Current rating 200mA

Class I, Div. 1, Groups A, B, C, D;

Power Supply Unit

Class III, Div. 1;

Class I, Zone 0, Group IIC;

Class II, Zone 20;

Class II, Zone 21, Group IIIC;

Canada: Class I, Div. 2, Groups A, B, C, D;

Class II, Div. 1, Groups E, F, G;

o o o oAmbient temperature range -40 F to +140 F (-40 C to +60 C)

Power rating 10 watt

Canada/USA Class I, Div. 2, Groups A, B, C, D; Class I, Zone 2, Group IIC;

Provides intrinsically safe output for

Construction Static Dissipative Glass-Reinforced Polyester or Stainless Steel

Weight 4.5 kgs (nett)

Class II, Div. 1, Groups E, F, G;

Class III, Div. 1.o Ex nA[ia Ga] nC IIC T4 Gc. Ex tb IIIC T65 C Db.

Certification Suitable for use in

Class III, Div. 1;

Ingress protection IP66

Class II, Div. 1, Groups E, F, G;

Standard Cable entries 3 x 20mm plus 1 x 25mm diameter

6 x 20mm diameter and 1 x 25mm diameter (Stainless Steel Enclosure)

2Terminals 29 x 12AWG (4.00mm ) conductor capacity standard blue terminals

Class II, Div. 1, Groups E, F, G;

2 1 x 10AWG (6.00mm ) conductor capacity ground terminal

Stowage device Insulated pin

o o o oAmbient temperature range -40 F to +140 F (-40 C to +60 C)

Ex ia IIIC T135°C DaUSA: Class I, Zone 0, AEx ia IIC T4 Ga

Weight 4.5 kgs (nett)

2Terminals 5 x 14AWG (2.5mm ) conductor capacity

Construction Stainless Steel housing with polycarbonate window

Monitoring circuit Intrinsically safe

Certification Intrinsically Safe Equipment Exia for use in

8-Way Marshalling Box

Enclosure Type 4X, IP66

Enclosure GRP or Stainless Steel

Class II, Zone 20, AEx ia IIIC T135°C Da

2 1 x 10AWG (6.00mm ) conductor capacity ground terminal

10 x 20mm diameter and 1 x 25mm diameter (Stainless Steel Enclosure)

Note: NPT threaded adapters are available

Canada/USA: Class I, Div. 1, Groups A, B, C, D;

Note: NPT threaded adapters are available

Cable entries 10 x M20 and 1 x M25 (GRP Enclosure)

2) 4 x 12AWG (4.00mm conductor capacity ground terminals

4-Way Marshalling Box

Operational series ground resistance </= 10 Ohm

Enclosure GRP or Stainless Steel

Monitoring Unit

Class III, Div. 1Canada: Ex ia IIC T4 Ga

2Terminals 15 x 12AWG (4.00mm ) conductor capacity standard blue terminals2 2 x 12AWG (4.00mm ) conductor capacity ground terminals

Cable entries 6 x M20 and 1 x M25 (GRP Enclosure)

Note: NPT threaded adapters are available

Remote Indicator Station

Enclosure GRP or Stainless Steel

Cable entry 1 x M20 (GRP Enclosure)

1 x 20mm diamteter (Stainless Steel Enclosure)

NPT threaded adapters are availableNote:

Cable Out Connection Quick Connect

NB: In line with our policy of continual product development, we reserve the right to alter specifications at any time.

Warranty

A two year manufacturer's warranty applies to Newson Gale electronic modules. This is subject to the general terms and conditions and correct installation / usage of the product.

www.newson-gale.comwww.newson-gale.com

Page 32: Earth-Rite® MULTIPOINT II - Redlands

32 33www.newson-gale.comwww.newson-gale.com32 33

We, Newson Gale Ltd., Omega House, Private Road 8

Colwick, Nottingham - NG4 2JX - UK

Declare under our sole responsibility that the product:

Product name: Earth-Rite Multipoint II

To which this declaration relates is in conformity with the requirements of thefollowing specifications:

FCC 47 Part 15 Class A,

Supplementary information:This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Signed for the manufacturer :

Name (in writing) : Ian J EdgeTitle : Electrical EngineerPlace and date of issue : Nottingham, February 13th 2018

De

clar

atio

n o

f C

on

form

ity

- G

LD -

FC

C.v

sdx

Declaration of Conformity

Omega House, Private Road 8Colwick, Nottingham - NG4 2JX - UK

Tel: (0)115 940 7500 Fax: (0)115 940 7501

Email: [email protected]: www.newson-gale.com

Notes relating to FCC Part 15:

Changes or modifications to the equipment, not approved by the responsible party, will void the user’s authority to operate the equipment.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

Page 33: Earth-Rite® MULTIPOINT II - Redlands

32 33www.newson-gale.comwww.newson-gale.com32 33

We, Newson Gale Ltd., Omega House, Private Road 8

Colwick, Nottingham - NG4 2JX - UK

Declare under our sole responsibility that the product:

Product name: Earth-Rite Multipoint II

To which this declaration relates is in conformity with the requirements of thefollowing specifications:

FCC 47 Part 15 Class A,

Supplementary information:This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Signed for the manufacturer :

Name (in writing) : Ian J EdgeTitle : Electrical EngineerPlace and date of issue : Nottingham, February 13th 2018

De

clar

atio

n o

f C

on

form

ity

- G

LD -

FC

C.v

sdx

Declaration of Conformity

Omega House, Private Road 8Colwick, Nottingham - NG4 2JX - UK

Tel: (0)115 940 7500 Fax: (0)115 940 7501

Email: [email protected]: www.newson-gale.com

Notes relating to FCC Part 15:

Changes or modifications to the equipment, not approved by the responsible party, will void the user’s authority to operate the equipment.

These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.

Page 34: Earth-Rite® MULTIPOINT II - Redlands

34 35www.newson-gale.comwww.newson-gale.com34 35

Page 35: Earth-Rite® MULTIPOINT II - Redlands

34 35www.newson-gale.comwww.newson-gale.com34 35

Page 36: Earth-Rite® MULTIPOINT II - Redlands

36 #

NG

US

ER

MU

LTIP

OIN

T II IS

M 1

70

61

9 R

6

[email protected]

+44 (0)115 940 7500

NG4 2JX, UK

United Kingdom

Newson Gale Ltd

Omega House

Private Road 8

Colwick, Nottingham

+49 (0)2102 5889 0

[email protected]

IEP Technologies GmbH

40878 Ratingen

Germany

Kaiserswerther Str. 85C

Deutschland

[email protected] East Asia

417-1 South Street

United States

Marlborough, MA 01752

+1 732 961 7610

[email protected]

USA

IEP Technologies LLC