eae e - cbi-lowvoltage.co.za

2
Circuit Breakers for Equipment Page 15 low voltage DC Range Overview QY- Bridged B-frame C-frame DD-frame G37D RAU DC Range MCCB Voltages Current Fault Level B-Frame 24, 48, 65, 80 Vdc (300 Vdc - switch only, 10 A) up to 30 A 0.6 kA C-Frame MKIV 65, 80 Vdc up to 50 A 4 kA DD-Frame * (RAU option available) 80 Vdc up to 400 A 10 kA QY (13) * 80, 125 Vdc (250 Vdc up to 50 A) up to 200 A 10 kA JS25 80 Vdc 80 to 250 A 25 kA JS25S 80 Vdc 300 to 750 A 20 kA L20B 125 Vdc 800 to 1500 A 20 kA G37D 250, 500 Vdc 15 to 125 A 20 kA (at 500 Vdc) F37D 250, 500 Vdc 150 to 250 A 20 kA (at 500 Vdc) K50D 250, 500 Vdc 250 to 400 A 20 kA (at 500 Vdc) L65D 250, 500 Vdc 500 to 800 A 20 kA (at 500 Vdc) G150D 250, 500, 750, 1000 Vdc 16 to 160 A 100 kA (at 1000 Vdc) F150D 250, 500, 750, 1000 Vdc 40 to 250 A 100 kA (at 1000 Vdc) K150D 250, 500, 750, 1000 Vdc 300 to 630 A 100 kA (at 1000 Vdc) L150D 250, 500, 750, 1000 Vdc 800 A 100 kA (at 1000 Vdc) Notes: Contact CBI for details. Full range’s data sheets available on www.cbi-lowvoltage.com. Standard discounts are not applicable. * DIN rail option available.

Transcript of eae e - cbi-lowvoltage.co.za

Circuit B

reakers for Equipment

Page 15

low voltage

DC Range Overview

QY- Bridged B-frame C-frame DD-frame G37DRAU

DC RangeMCCB Voltages Current Fault Level

B-Frame 24, 48, 65, 80 Vdc(300 Vdc - switch only, 10 A) up to 30 A 0.6 kA

C-Frame MKIV 65, 80 Vdc up to 50 A 4 kA

DD-Frame *(RAU option

available)80 Vdc up to 400 A 10 kA

QY (13) * 80, 125 Vdc (250 Vdc up to 50 A) up to 200 A 10 kA

JS25 80 Vdc 80 to 250 A 25 kA

JS25S 80 Vdc 300 to 750 A 20 kA

L20B 125 Vdc 800 to 1500 A 20 kA

G37D 250, 500 Vdc 15 to 125 A 20 kA (at 500 Vdc)

F37D 250, 500 Vdc 150 to 250 A 20 kA (at 500 Vdc)

K50D 250, 500 Vdc 250 to 400 A 20 kA (at 500 Vdc)

L65D 250, 500 Vdc 500 to 800 A 20 kA (at 500 Vdc)

G150D 250, 500, 750, 1000 Vdc 16 to 160 A 100 kA (at 1000 Vdc)

F150D 250, 500, 750, 1000 Vdc 40 to 250 A 100 kA (at 1000 Vdc)

K150D 250, 500, 750, 1000 Vdc 300 to 630 A 100 kA (at 1000 Vdc)

L150D 250, 500, 750, 1000 Vdc 800 A 100 kA (at 1000 Vdc)

Notes:

Contact CBI for details. Full range’s data sheets available on www.cbi-lowvoltage.com. Standard discounts are not applicable. * DIN rail option available.

Circ

uit B

reak

ers

for E

quip

men

t

Page 16

low voltage

DC Range Overview

QDC-1(13) QDC-2(13)

QDC Range: 80 Vdc Circuit Breakers, 10 kA, Curve U2, Dual Mount and DIN rail mount

Type Poles Voltage kA MCB Width (mm) Rating (A) Price Ea.

excl. VAT Order No.

QDC-1(13)-DM-U2-5A-B0(Grey Handle) 1 80 Vdc 10 13

(1 Module)

5, 6 R 129.00

QDC18U2..B010, 15, 20 R 133.00

25, 30, 35, 40 R 148.00

45, 50, 60 R 153.00

QDC-2(13)-DM-U2-5A-B0(Grey Handle) 2 80 Vdc 10 26

(2 Module)

5 R 313.00

QDC28U2..B010, 15, 20 R 320.00

25, 30, 35, 40 R 358.00

45, 50, 60 R 370.00

QDC-2(13)-DM-U2-080A-B0-ZL(Grey Handle) 2 (Parallel) 80 Vdc 10 26

(2 Module)80 R 370.00

QDC28U2...B0ZL100 R 482.00

QDC-3(13)-DM-U2-125A-B0-ZL(Grey Handle) 3 (Parallel) 80 Vdc 10 39

(3 Module)125 R 689.00

QDC38U2...B0ZL150 R 990.00

QDC-4(13)-DM-U2-200A-B0-ZL(Grey Handle) 4 (Parallel) 80 Vdc 10 52

(4 Module) 200 R 1 452.00 QDC49U2200B0ZL

QDC Range: 125 Vdc Circuit Breakers, 10 kA, Curve U2, Dual Mount and DIN rail mount

Type Poles Voltage kA MCB Width (mm) Rating (A) Price Ea.

excl. VAT Order No.

QDC-1(13)-DM-U2-5A-B1(Grey Handle) 1 125 Vdc 10 13

(1 Module)

5 R 156.00

QDC18U2..B110, 15, 20 R 158.00

25, 30, 35, 40 R 179.00

45, 50, 60 R 183.00

QDC-2(13)-DM-U2-5A-B1(Grey Handle) 2 125 Vdc 10 26

(2 Module)

5 R 376.00

QDC28U2..B110, 15, 20 R 384.00

25, 30, 35, 40 R 431.00

45, 50, 60 R 443.00

QDC-2(13)-DM-U2-080A-B1-ZL(Grey Handle) 2 (Parallel) 125 Vdc 10 26

(2 Module)80 R 443.00

QDC28U2...B1ZL100 R 578.00

QDC-3(13)-DM-U2-125A-B1-ZL(Grey Handle) 3 (Parallel) 125 Vdc 10 39

(3 Module) 125, 150 R 1 118.00 QDC38U2...B1ZL

Notes:

Contact CBI for details. Full range’s data sheets available on www.cbi-lowvoltage.com. Standard discounts are not applicable. * DIN rail option available.