E200 Series · scrubbers, liquid accumulators & process vessels 316 Stainless Steel construction...
Transcript of E200 Series · scrubbers, liquid accumulators & process vessels 316 Stainless Steel construction...
E200 Series
m
Electric Level Control SwitchApplication – High & Low Liquid Level Control; WP 1500 psig • •
•
•
• •
• • • • • • • • • • •
Float-actuated Electric Switch for Level Control Provides Electric Switch input for control systems, alarms and other switch operations Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels 316 Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .4 and above Direct mounting inside vessel or External Float Cage
Features and Benefits of the Pathway E200 316 SS wetted components for Durability and Corrosion Resistance Explosion Proof Certification by CSA to USA and Canada StandardsSingle Seal Application Approved Hermetically Sealed Reed Switch Cartridge to protect Integrity of SwSPST and SPDT Switch Cartridges in Standard and Light Load RatinNo Internal Seal used thus eliminating the possibility of process fluid Few Moving Parts for Reduced Maintenance and long term PerformaExcellent Serviceability including Quick Replacement of Electric SwitDisplacer options for various Pressure, Specific Gravity and InterfaceNormally Open or Closed operation by simply inverting Level ControlRelay Assembly in Explosion Proof enclosure for DPDT and Higher A
Specifications Working Pressure: 1500 psig; available up to 5000 psig; 1500 psig with mTemperature: -40º F to +392º F Specific Gravity: 0.4 minimum; interface 0.1 differential minimum Switch Ratings: SPST and SPDT 250V – 0.40A resistive, 120V – 0.83
resistive; 3.0A maximum in-rush capability; 4 watts min SPST and SPDT Light Load 150V – 0.17A resistive, 1
1.0A resistive; 1.0A maximum in-rush capability; 0.1 wMaterials: 316 Stainless Steel Wetted components; Hermetically Process Connection: 1½” NPT standard, 2” NPT, ring bolt on E200C, 3” flanElectrical Connection: ½” NPT conduit Certification: CSA: Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1
Div. 1 to USA & Canada Standards; (rating with relay e Groups C,D; Class II, Div. 1, Groups E,F,G; Class II, D CSA: Single Seal applications per ANSI/ISA 12.27.01-
E200 Common Options • • • •
• • • •
• •
Manual Override for Field Testing 316 SS and 304 SS flange Extended body with Vertical displacer Monel float
SPST extended lFloat arm extensRelay for DPDT aAnnulus plug for
Benefits of ALL Pathway Control Products Personalized Service and Support expertise; Responsive, On-time DTime-tested & proven design providing Dependable, Long-term Serv
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
to 5000 psig
itch Contacts gs leakage nce ch Cartridge applications unit mperage service
anual override
A resistive, 24V – 3.0A imum for proper switching
10V – 0.23A resistive, 24V – atts minimum for switching sealed reed switch ged or larger
, Groups E, F, G; Class III, nclosure Class I, Div. 1&2, iv. 2, Groups F,G; Class III ) 2003
eads ions nd Higher Amperage
use with sediments
elivery ice
E200 Series Electric Level Control Switch
Dimensions:
Ordering Chart: E200 Series: Electric Level Control Switch E200C: Ring Bolted External Cage; WP 1500 psig to 3000 psig (body sBody Style:
0 1½” NPT standard body; Ring Bolted on E200C (no manual over1 2
3
2” NPT 1½” NPT, manual override*
3 Extended body, 2” NPT, vertical displacer (type 3 or 9) 4 2” NPT, manual override* 6 Extended body, 2” NPT, manual override*, vertical displacer (7 Extended body, 2” NPT, horizontal displacer (type 3 or 9) 8 Extended body, 2” NPT manual override*, horizontal displace *WP 1500 psig on manual override
Displacer Type: 1 316 SS standard float, WP 1500 psig, 0.4 SG min (body style 0, 2 Polypropylene high pressure displacer, WP 5000 psig standar on E200C, +180º F max temp; 0.6 SG min (body style 0, 1, 2, 4)
Interface Polypropylene displacer, WP 5000 psig standard, 30 E200C, +180º F max temp; upper fluid < .870 SG, lower fluid 4 Customer defined SG for upper and lower fluid interface 9 Polypropylene high pressure displacer, WP up to 5000 psig, + temp, 0.5 SG min (extended body style 3, 6, 7, 8)
Switch selection: 0 SPST standard load 1 SPDT standard load 2 SPST light load 3 SPDT light load
Other: 0 No other options 2 Annulus plug 3 Relay assembly general purpose plug-in, 24VDC DPDT 12 Am4 Relay assembly general purpose plug-in, 120VAC DPDT 12 A7 Relay assembly general purpose plug-in, 240VAC DPDT 12 A8 Relay assembly hermetically sealed plug-in, 24VDC DPDT 129 Relay assembly hermetically sealed plug-in, 120VAC DPDT 15 Customer Specified Requirements (see E200 common option
Option (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
Example:
E200 tyle 0)
ride on ring bolt) 0
type 3 or 9)
r (type 3 or 9)
1, 2, 4) 1 d, 3000 psig
00 psig on > .970 SG
180º F max
0
0
p mp mp Amp 2 Amp s)
E200 - 01 - 00
E200 Series – Manual OveElectric Level Control Switc
Application – High & Low Liquid Level Control; WP up to 150•
•
• • •
•
• • • • • • • • • •
Float-actuated Electric Switch for High & Low Liquid Level Control and Interface Control Provides Electric Switch input for control systems, alarms or other switch operations Low Specific Gravity of .4 and above Interface as low as .1 Specific Gravity differential Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Direct mounting inside vessel or threaded External Float Cage
Features and Benefits of the Pathway E200 with Manual OveManual Override for ease of Field Testing 316 SS wetted components for Durability and Corrosion ResistanceExplosion Proof Certification by CSA to USA and Canada StandardSingle Seal application Approved Hermetically Sealed Switch Cartridge to protect Integrity of Switch CSPST and SPDT Switch Cartridges in Standard and Light Load RaFew Moving Parts for Reduced Maintenance and long term PerformExcellent Serviceability including Quick Replacement of Electric SwDisplacer options for various Pressure, Specific Gravity and InterfaRelay Assemblies in Explosion Proof enclosures for DPDT and Hig
Specifications Working Pressure: Pressures up to 1500 psig with manual override Temperature: -40º F to +392º F Specific Gravity: 0.4 minimum; interface 0.1 differential minimum Switch Rating: SPST and SPDT 250V – 0.40A resistive, 120V – 0.
resistive; 3.0A maximum in-rush capability; 4 watts m SPST and SPDT Light Load 150V – 0.17A resistive,
1.0A resistive; 1.0A maximum in-rush capability; 0.1Materials: 316 Stainless Steel Wetted components; HermeticalProcess Connection: 1½” NPT standard, 2” NPT, 3” flanged or larger Electrical Connection: ½” NPT conduit Certification: CSA: Class I, Div. 1, Groups A, B, C, D; Class II, Div
Div. 1 to USA & Canada Standards; (rating with rela Groups C,D; Class II, Div. 1, Groups E,F,G; Class II, CSA: Single seal applications per ANSI/ISA 12.27.0
E200 Manual Override Common Options • • • •
• • •
• •
316 SS and 304 SS flange Extended body with Vertical Displacer Monel float SPST extended leads
Float arm exteAnnulus plug fRelay for DPD
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-time DTime-tested & proven design providing Dependable, Long-term ser
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
rride h 0 psig
rride
s
ontacts tings ance itch Cartridge
ce applications her Amperage service
83A resistive, 24V – 3.0A inimum for proper switching
110V – 0.23A resistive, 24V – watts minimum for switching ly sealed reed switch
. 1, Groups E, F, G; Class III, y enclosure Class I, Div. 1&2, Div. 2, Groups F,G; Class III ) 1-2003
nsions or use with sediments T and Higher Amperage
elivery vice
E200 Series – Manual OverElectric Level Control Switch
Dimensions:
Ordering Chart: E200 Series: Electric Level Control Switch E200C: Ring Bolted External Cage; WP 1500 psig to 3000 psig (body sBody Style:
0 1½” standard body; Ring bolted on E200C (no manual override on1 2
3
2” NPT 1½” NPT, manual override*
3 Extended body, 2” NPT, vertical displacer (type 3 or 9) 4 2” NPT, manual override* 6 Extended body, 2” NPT, manual override*, vertical displacer (7 Extended body, 2” NPT, horizontal displacer (type 3 or 9) 8 Extended body, 2” NPT manual override*, horizontal displace *WP 1500 psig on manual override
Displacer Type: 1 316 SS standard float, WP 1500 psig, 0.4 SG min (body style 0, 2 Polypropylene high pressure displacer, WP 5000 psig standar on E200C, +180º F max temp; 0.6 SG min (body style 0, 1, 2, 4)
Interface Polypropylene displacer, WP 5000 psig standard, 30 E200C, +180º F max temp; upper fluid < .870 SG, lower fluid 4 Customer defined SG for upper and lower fluid interface 9 Polypropylene high pressure displacer, WP up to 5000 psig, + temp, 0.5 SG min (extended body style 3, 6, 7, 8)
Switch selection: 0 SPST standard load 1 SPDT standard load 2 SPST light load 3 SPDT light load
Other: 0 No other options 2 Annulus plug 3 Relay assembly general purpose plug-in, 24VDC DPDT 12 Am4 Relay assembly general purpose plug-in, 120VAC DPDT 12 A7 Relay assembly general purpose plug-in, 240VAC DPDT 12 A8 Relay assembly hermetically sealed plug-in, 24VDC DPDT 129 Relay assembly hermetically sealed plug-in, 120VAC DPDT 15 Customer Specified Requirements (see E200 common option
Option (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
ride
Example: E200-
tyle 0)
ring bolt)
4 type 3 or 9)
r (type 3 or 9)
1, 2, 4) 1 d, 3000 psig
00 psig on > .970 SG
180º F max
1
0
p mp mp Amp 2 Amp s)
E200 - 41 - 10
E200 Series – Extended Bo
m
Electric Level Control SwitchApplication – High & Low Liquid Level Control; WP 1500 psig • •
•
•
• • •
• • • • • • • • • • •
Float-actuated Electric Switch for Level Control Provides Electric Switch input for control systems, alarms and other switch operations Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels 316 Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .5 and above Horizontal and Vertical Displacer options Extended Body provides increased reach inside vessel
Features and Benefits of the Pathway E200 316 SS wetted components for Durability and Corrosion Resistance Explosion Proof Certification by CSA to USA and Canada StandardsSingle Seal Application Approved Hermetically Sealed Reed Switch Cartridge to protect Integrity of SwSPST and SPDT Switch Cartridges in Standard and Light Load RatinNo Internal Seal used thus eliminating the possibility of process fluid Few Moving Parts for Reduced Maintenance and long term PerformaExcellent Serviceability including Quick Replacement of Electric SwitDisplacer options for various Pressure, Specific Gravity and InterfaceNormally Open or Closed operation by simply inverting Level ControlRelay Assembly in Explosion Proof enclosure for DPDT and Higher A
Specifications Working Pressure: 1500 psig; available up to 5000 psig; 1500 psig with mTemperature: -40º F to +392º F Specific Gravity: 0.4 minimum; interface 0.1 differential minimum Switch Ratings: SPST and SPDT 250V – 0.40A resistive, 120V – 0.83
resistive; 3.0A maximum in-rush capability; 4 watts min SPST and SPDT Light Load 150V – 0.17A resistive, 1
1.0A resistive; 1.0A maximum in-rush capability; 0.1 wMaterials: 316 Stainless Steel Wetted components; Hermetically Process Connection: 1½” NPT standard, 2” NPT, ring bolt on E200C, 3” flanElectrical Connection: ½” NPT conduit Certification: CSA: Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1
Div. 1 to USA & Canada Standards; (rating with relay e Groups C,D; Class II, Div. 1, Groups E,F,G; Class II, D CSA: Single Seal applications per ANSI/ISA 12.27.01-
E200 Extended Body Common Options • • •
• • •
• •
Manual Override for Field Testing 316 SS and 304 SS flange SPST extended leads
Float arm extensRelay for DPDT aAnnulus plug for
Benefits of ALL Pathway Control Products Personalized Service and Support expertise; Responsive, On-time DTime-tested & proven design providing Dependable, Long-term Serv
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
dy to 5000 psig
itch Contacts gs leakage nce ch Cartridge applications unit mperage service
anual override
A resistive, 24V – 3.0A imum for proper switching
10V – 0.23A resistive, 24V – atts minimum for switching sealed reed switch ged or larger
, Groups E, F, G; Class III, nclosure Class I, Div. 1&2, iv. 2, Groups F,G; Class III ) 2003
ions nd Higher Amperage
use with sediments
elivery ice
E200 Series – Extended BElectric Level Control Switch
Dimensions:
Ordering Chart: E200 Series: Electric Level Control Switch E200C: Ring Bolted External Cage; WP 1500 psig to 3000 psig (body sBody Style:
0 1½” NPT standard body; Ring Bolted on E200C (no manual over1 2
3
2” NPT 1½” NPT, manual override*
3 Extended body, 2” NPT, vertical displacer (type 3 or 9) 4 2” NPT, manual override* 6 Extended body, 2” NPT, manual override*, vertical displacer (7 Extended body, 2” NPT, horizontal displacer (type 3 or 9) 8 Extended body, 2” NPT manual override*, horizontal displace *WP 1500 psig on manual override
Displacer Type: 1 316 SS standard float, WP 1500 psig, 0.4 SG min (body style 0, 2 Polypropylene high pressure displacer, WP 5000 psig standar on E200C, +180º F max temp; 0.6 SG min (body style 0, 1, 2, 4)
Interface Polypropylene displacer, WP 5000 psig standard, 30 E200C, +180º F max temp; upper fluid < .870 SG, lower fluid 4 Customer defined SG for upper and lower fluid interface 9 Polypropylene high pressure displacer, WP up to 5000 psig, + temp, 0.5 SG min (extended body style 3, 6, 7, 8)
Switch selection: 0 SPST standard load 1 SPDT standard load 2 SPST light load 3 SPDT light load
Other: 0 No other options 2 Annulus plug 3 Relay assembly general purpose plug-in, 24VDC DPDT 12 Am4 Relay assembly general purpose plug-in, 120VAC DPDT 12 A7 Relay assembly general purpose plug-in, 240VAC DPDT 12 A8 Relay assembly hermetically sealed plug-in, 24VDC DPDT 129 Relay assembly hermetically sealed plug-in, 120VAC DPDT 15 Customer Specified Requirements (see E200 common option
Option (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
ody
Example:
E200 tyle 0)
ride on ring bolt)
type 3 or 9) 7
r (type 3 or 9)
1, 2, 4) d, 3000 psig
00 psig on > .970 SG
180º F max 9
1
0
p mp mp Amp 2 Amp s)
E200 - 79 - 10
EV200 Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
Electric Vertical Level Control Switch Application – High & Low Liquid Level Control; WP 250 psig • •
• •
• • • • • • • • • • •
Float-actuated Electric Vertical Switch for High & Low Liquid Level Control Provides Electric Switch input for control systems, alarms or other switch operations Low Specific Gravity of .7 and above Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels
Features and Benefits of the Pathway EV200 316 SS wetted components for Durability and Corrosion Resistance Explosion Proof Certification by CSA to USA and Canada Standards Single Seal Application Approved Hermetically Sealed Switch Cartridge to protect Integrity of Switch Contacts SPST and SPDT Switch Cartridges in Standard and Light Load Ratings No Internal Seal thus eliminating the possibility of process fluid leakage Normally Open or Normally Closed Operation Float options and Float Arm extensions to meet most applications Few Moving Parts for Reduced Maintenance and long term Performance Excellent Serviceability including Quick Replacement of Electric Switch Cartridge Relay Assemblies in Explosion Proof enclosures for DPDT and Higher Amperage se
Specifications Working Pressure: 250 psig Temperature: -40º F to +392º F Specific Gravity: 0.7 minimum Switch Rating: SPST and SPDT 250V – 0.40A resistive, 120V – 0.83A resistive, 24V
resistive; 3.0A maximum in-rush capability; 4 watts minimum for proper SPST and SPDT Light Load 150V – 0.17A resistive, 110V – 0.23A resis
1.0A resistive; 1.0A maximum in-rush capability; 0.1 watts minimum for Materials: 316 Stainless Steel Wetted components; Hermetically sealed reed switcProcess Connection: 1½” NPT standard, 2” NPT, 2” flanged or larger Electrical Connection: ½” NPT conduit Certification: CSA: Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1, Groups E, F, G
Div. 1 to USA & Canada Standards; (rating with relay enclosure Class I, Groups C,D; Class II, Div. 1, Groups E,F,G; Class II, Div. 2, Groups F,G CSA: Single seal applications per ANSI/ISA 12.27.01-2003
EV200 Common Options • • •
• •
• •
316 SS and 304 SS flange Variety of float extensions and floats Float arm turbulence protective guide
SPST extended leads Relay for DPDT and Higher Am
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-time Delivery Time-tested & proven design providing Dependable, Long-term service
rvice
– 3.0A switching tive, 24V – switching h
; Class III, Div. 1&2,; Class III )
perage
EV200 Series m
Electric Vertical Level Control SDimensions:
Ordering Chart: EV200 Series: Electric Vertical Level Control Switch; WP 250 psig Body Style:
0 1½” NPT, standard body, normally open 1 2” NPT, normally open 2 1½” NPT, normally closed 3 2” NPT, normally closed
Displacer Type: 1 3” O.D. 316 SS standard float with 4” float arm 2 3” O.D. 316 SS float, extended arm 4+” to 12” (specify length) 3 3½” x 6”, 316 SS float, extended arm 12” to 36” (specify length4 5½” O.D. 316 SS float, extended arm 36” to 72” (specify length6 5½” O.D. 316 SS float, extended arm 72” to 96” (specify length5 Optional float sizes and float arm extensions (Customer to spe
Switch selection: 0 SPST Standard load 1 SPDT Standard load 2 SPST Light load 3 SPDT Light load
Other: 0 No other options selected 1 Float arm turbulence protective guide 3 Relay assembly general purpose plug-in, 24VDC DPDT 12 Am4 Relay assembly general purpose plug-in, 120VAC DPDT 12 A7 Relay assembly general purpose plug-in, 240VAC DPDT 12 A8 Relay assembly hermetically sealed plug-in, 24VDC DPDT 12 9 Relay assembly hermetically sealed plug-in, 120VAC DPDT 125 Customer Specified Requirements (see EV200 common option
Option (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
witch
Example: EV200-
0
1
) ) ) cify)
0
1 p
mp mp Amp Amp s)
EV200 - 01 - 01
E200NF Series
m
Electric Flow Indicator Application – Flow Indicator; WP up to 5000 psig •
•
•
•
• • • • • • • • • • •
Paddle operated Electric Indicator of liquid or gas flow or no flow in piping systems Provides Electric Switch input for control systems, alarms or other operations Liquid Flow indicated at 1.0 ft./sec and greater; No flow indicated at less than .75 ft./sec Direct mounting inside vessel or pipe
Features and Benefits of the Pathway E200NF 316 SS wetted components for Durability and Corrosion Resistance Explosion Proof Certification by CSA to USA and Canada StandardsSingle Seal Application Approved Wide variety of Paddle lengths to meet most applications No Internal Seal used thus eliminating the possibility of process fluid Hermetically Sealed Switch Cartridge to protect Integrity of Switch CSPST and SPDT Switch Cartridges in Standard and Light Load RatinFew Moving Parts for Reduced Maintenance and long term PerformaExcellent Serviceability and quick replacement of Electric Switch CarSimply Rotate the device to change flow sensing direction Relay Assembly in Explosion Proof enclosures for DPDT and Higher
Specifications Working Pressure: 5000 psig; 1500 psig with manual override Temperature: -40º F to +392º F Switch Rating: SPST and SPDT 250V – 0.40A resistive, 120V – 0.83
resistive; 3.0A maximum in-rush capability; 4 watts min SPST and SPDT Light Load 150V – 0.17A resistive, 1
1.0A resistive; 1.0A maximum in-rush capability; 0.1 wMaterials: 316 Stainless Steel Wetted components; Hermetically Process Connections: 1½” NPT standard, 2” NPT, 2” flanged or larger Electrical Connections: ½” NPT conduit Certification: CSA: Class I, Div. 1, Groups A, B, C, D; Class II, Div. 1
Div. 1 to USA & Canada Standards; (rating with relay e Groups C,D; Class II, Div. 1, Groups E,F,G; Class II, D CSA: Single seal applications per ANSI/ISA 12.27.01-2
E200NF Common Options • • •
• • •
• •
316 SS and 304 SS flange Variety of paddle lengths SPST extended leads
Manual OverrideRelay for DPDTAnnulus plug for
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-time DeTime-tested & proven design providing Dependable, Long-term servi
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
leakage ontacts gs nce tridge
Amperage se
A resistive, 24imum for prop
10V – 0.23A reatts minimum sealed reed sw
, Groups E, Fnclosure Clasiv. 2, Groups 003
for Field Te and Higher A use with sed
livery ce
rvice
V – 3.0A er switching sistive, 24V –
for switching itch
, G; Class III, s I, Div. 1&2, F,G; Class III )
sting mperage iments
E200NF Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
Electric Flow Indicator Dimensions:
Ordering Chart: Example: E200NF Series: Electric Flow Indicator; WP 5000 psig standard E200NF- Body Style:
0 1½” NPT standard body 0 1 2” NPT
Paddle Type: 1 1½” standard paddle length 1 2 2” paddle length 3 3” paddle length 4 4” paddle length 6 6” paddle length 8 8” paddle length 0 10” paddle length 5 Customer Specified paddle length
Switch selection: 0 SPST Standard load 1 SPDT Standard load 2 SPST Light load 2 3 SPDT Light load
Other: 0 No other options 0 2 Annulus plug 3 Relay assembly general purpose plug-in, 24 VDC DPDT 12 Amp 4 Relay assembly general purpose plug-in, 120 VAC DPDT 12 Amp 7 Relay assembly general purpose plug-in, 240 VAC DPDT 12 Amp 8 Relay assembly hermetically sealed plug-in, 24 VDC DPDT 12 Amp 9 Relay assembly hermetically sealed plug-in 120 VAC DPDT 12 Amp 5 Customer Specified Requirements (see E200NF common options)
Option (#) Assigned # for Customer Specific requirements Example as Selected E200NF - 01 - 20
P120 Series
m
Snap Acting Non-Bleed Pneumatic Leve
Application – High & Low Liquid Level Control; WP 1500 p•
•
•
• • •
• • • • • • •
• • • •
• •
• •
• •
Float-actuated Pneumatic Switch for High or Low Level control or to operate Control Valves Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .5 and above Snap Acting Non-Bleed from 0 to full supply Direct mounting inside vessel or External Float Cage
Features and Benefits of the Pathway P120 Durable, Dependable 316 SS wetted components for CorrosionNo Internal Seal used thus eliminating the possibility of processFew Moving Parts for Reduced Maintenance and long term PerExcellent Serviceability and Ease of Repair with Quick-change rEconomical small-float installation Displacer options for various Pressure, Specific Gravity and InteDirect-acting or Indirect-acting simply by altering the supply and
Specifications Output: Snap Acting, Non-Bleed from 0 to Full Supply Working Pressure: 1500 psig; available up to 5000 psig; 1500 psig Supply Pressure: 30 psig standard; 60 psig and 100 psig availableTemperature: -40º F to +450º F Specific Gravity: 0.5 minimum; 0.4 minimum with counterweight; Materials: 316 Stainless Steel Wetted components; optionaProcess Connection: 2” NPT standard, 1½” NPT, Ring Bolt on P120CSupply/Output Connection: ¼” NPT
P120 Common Options Manual Override for Field Testing 1½” NPT process connection 316 SS and 304 SS flanged Float Arm Extensions of 2”, 4”, 6” on standard body style
Counterweight for LExtended body withvertical displacer Stainless Steel VenAnnulus Plug for us
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-timTime-tested & Proven design providing Dependable, Long-term
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
l Control
sig to 5000 psig
Resistance fluid leakage formance eplacement parts
rface applications exhaust connections
with manual override
interface 0.1 differential l materials available
, 3” flanged or larger
ower S.G. horizontal or
t assembly e with sediments
e Delivery service
P120 Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
Snap Acting Non-Bleed Pneumatic Level Control Dimensions:
Ordering Chart: Example: P120 Series: Pneumatic Level Control P120- P120C: Ring Bolted External Cage, WP 1500 psig to 3000 psig (body style 0) Body Style:
0 Ring bolted body on P120C (no manual override; no extended body) 2” NPT standard body 1 1
1 2 3
0
2 2” NPT, manual override* 3 Extended body, 2” NPT, vertical displacer (type 3 or 9) 6 Extended body, 2” NPT, manual override*, vertical displacer (type 3 or 9) 7 Extended body, 2” NPT, horizontal displacer (type 3 or 9) 8 Extended body, 2” NPT, manual override*, horizontal displacer (type 3 or 9) *WP 1500 psig on manual override
Displacer Type: 1 316 SS standard float, WP 1500 psig; 0.5 SG min (body style 0, 1, 2) 1 2 Polypropylene high pressure displacer, WP 5000 psig standard, 3000 psig on P120C; +180º F max temp; 0.6 SG min. (body style 0, 1, 2) 3 Interface Polypropylene displacer, WP 5000 psig standard, 3000 psig on P120C; +180º F max temp; upper fluid < .870 SG, lower fluid > .970 SG 4 Customer defined SG for upper and lower fluid interface 9 Polypropylene high pressure displacer, WP up to 5000 psig; +180º F max temp; 0.5 SG min (extended body style 3, 6, 7, 8)
Supply Pressure: 30 psig (flow rate 40 scfh at 30 psig) 1 60 psig (flow rate 25 scfh at 30 psig) 100 psig (flow rate 15 scfh at 30 psig)
Other: No other options 0
2: Annulus plug 5: Customer Specified Requirements (see P120 common options)
Option (# ): Assigned # for Customer Specific requirements Example as Selected P120 - 11 - 10
P120 Series – Manual OverrSnap Acting Non-Bleed Pneumatic Leve
Application – High & Low Liquid Level Control; WP up to •
• •
•
• • •
• • • • • • •
• • • •
•
•
• •
Float-actuated Pneumatic Switch for High or Low Level control or to operate Control Valves Manual Override provides easy In-service Testing Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .5 and above Snap Acting Non-Bleed from 0 to full supply Direct mounting inside vessel or threaded External Float Cage
Features and Benefits of the Pathway P120 with Manual Manual Override for ease of Field Testing Durable, Dependable 316 SS wetted components for CorrosionFew Moving Parts for Reduced Maintenance and long term PerExcellent Serviceability and Ease of Repair with Quick-change rEconomical small-float installation Displacer options for various Pressure, Specific Gravity and InteDirect-acting or Indirect-acting simply by altering the supply and
Specifications Output: Snap Acting, Non-Bleed from 0 to Full Supply Working Pressure: Pressures up to 1500 psig with Manual OverridSupply Pressure: 30 psig standard; 60 psig and 100 psig availablTemperature: -40º F to +450º F Specific Gravity: 0.5 minimum; 0.4 minimum with counterweight;Materials: 316 Stainless Steel Wetted components; optionProcess Connection: 2” NPT standard, 3” flanged or larger (1½” NPTSupply/Output Connection: ¼” NPT
P120 Manual Override Common Options 304 SS and 316 SS flange Counterweight for lower S.G. Annulus Plug for use with sediments Stainless Steel Vent assembly
Float Arm Extenstandard body sExtended body Vertical displace
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-timTime-tested & proven design providing Dependable, Long-term
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.pathwaycontrol.com
ide l Control
1500 psig
Override
Resistance formance eplacement parts
rface applications exhaust connections
e e
interface 0.1 differential al materials available not available)
sions of 2”, 4”, 6” on tyle with Horizontal or r
e Delivery service
P120 Series – Manual Ove
m
Snap Acting Non-Bleed Pneumatic LeDimensions:
Ordering Chart: P120 Series: Pneumatic Level Control P120C: Ring Bolted External Cage, WP 1500 psig to 3000 psig (bBody Style:
0 Ring bolted body on P120C (no manual override; no extended bo1 2 3
9
1 2 3
0
2” NPT standard body 2” NPT, manual override* Extended body, 2” NPT, vertical displacer (3 or 9)
6 Extended body, 2” NPT, manual override*, vertical displac7 Extended body, 2” NPT, horizontal displacer (3 or 9) 8 Extended body, 2” NPT, manual override*, horizontal disp *WP 1500 psig on manual override
Displacer Type: 1 316 SS standard float, WP 1500 psig, 0.5 SG min (body sty2 Polypropylene high pressure displacer, WP 5000 psig sta 3000 psig on P120C, +180º F max temp, 0.6 SG min (bod3 Interface Polypropylene displacer, WP 5000 psig standar P120C, +180º F max temp; upper fluid < .870 SG, lower f4 Customer defined SG for upper and lower fluid interface
Polypropylene high pressure displacer, WP up to 5000 ps max temp, 0.5 SG min (extended body style 3, 6, 7, 8)
Supply Pressure: 30 psig (flow rate 40 scfh at 30 psig) 60 psig (flow rate 25 scfh at 30 psig) 100 psig (flow rate 15 scfh at 30 psig)
Other: No other options
2: Annulus plug 5: Customer Specified Requirements (see P120 common op
Option (#): Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
rride vel Control
Example:
P120- ody style 0)
dy) 2
er (3 or 9)
lacer (3 or 9)
le 0, 1, 2) 1 ndard, y style 0, 1, 2) d, 3000 psig on luid > .970 SG
ig, +180º F
1
0
tions)
P120 - 21 - 10
P120 Series – Extended Bod
m
Snap Acting Non-Bleed Pneumatic Leve
Application – High & Low Liquid Level Control; WP 1500 to•
•
•
• • • • •
• • • • • • •
• •
• •
• •
Float-actuated Pneumatic Switch for High or Low Level control or to operate Control Valves Use on production separators, heaters/treaters, scrubbers, liquid accumulators, process vessels Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .5 and above Snap Acting Non-Bleed from 0 to full supply Direct mounting inside vessel or external adaptor Extended body provides increased reach inside the vessel Horizontal and Vertical Displacer options
Features and Benefits of the Pathway P120 Extended BodDurable, Dependable 316 SS wetted components for Corrosion RNo Internal Seal used thus eliminating the possibility of process fFew Moving Parts for Reduced Maintenance and long term PerfoEconomical, Simple installation Excellent Serviceability and Ease of Repair with Quick-change reDisplacer options for Interface applications Direct-acting or Indirect-acting simply by altering the supply and e
Specifications Output: Snap Acting, Non-Bleed from 0 to Full Supply Working Pressure: Pressures up to 5000 psig; 1500 psig with manuSupply Pressure: 30 psig standard; 60 psig and 100 psig availableTemperature: -40º F to +180º F Specific Gravity: 0.5 minimum; interface 0.1 differential minimum Materials: 316 Stainless Steel Wetted components with poProcess Connection: 2” NPT Standard, 3” flanged or larger, no ring boSupply/Output Connection: ¼” NPT
P120 Extended Body Common Options Manual Override for Field Testing 304 SS and 316 SS flanged
Float arm extensionsAnnulus Plug for use
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-timTime-tested & Proven design providing Dependable, Long-term s
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
y l Control
5000 psig
y esistance
luid leakage rmance
placement parts
xhaust connections
al override
lypropylene displacer lt with extended body
from 2 “ to 6” with sediments
e Delivery ervice
P120 Series – Extended Bo
m
Snap Acting Non-Bleed Pneumatic LevDimensions:
Ordering Chart: P120 Series: Pneumatic Level Control P120C: Ring Bolted External Cage, WP 1500 psig to 3000 psig (bodyBody Style:
0 Ring bolted body (no manual override; no extended body) 1 2” NPT standard body 2 2” NPT, manual override* 3 Extended body, 2” NPT, vertical displacer (Type 3, 9) 6 Extended body, 2” NPT, manual override*, vertical displacer7 Extended body, 2” NPT, horizontal displacer (Type 3, 9) 8 Extended body, 2” NPT, manual override*, horizontal displac *WP 1500 psig with manual override
Displacer Type: 1 316 SS standard float, 1500 psig, 0.5 SG min (body 0, 1, 2) 2 Polypropylene high pressure displacer, WP 5000 psig standa 3000 psig on P120C, +180º F max temp; SG 0.6 min. (body 03 Interface Polypropylene displacer, WP 5000 psig standard, 3 P120C, +180º F max temp, upper fluid < .870 SG, lower fluid4 Customer defined SG for upper and lower fluid interface 9 Polypropylene high pressure displacer, WP up to 5000 psig max temp, 0.5 SG min (extended body style 3, 6, 7, 8)
Supply Pressure: 30 psig (flow rate 40 scfh at 30 psig) 1
2 3
0
60 psig (flow rate 25 scfh at 30 psig) 100 psig (flow rate 15 scfh at 30 psig)
Other: No other options
2: Annulus plug 5: Customer Specified Requirements (see P120 common optio
Option (#): Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
dy el Control
Example:
P120- style 0)
(Type 3, 9) 7
er (Type 3, 9)
rd,
, 1, 2) 000 psig on > .970 SG
, +180º F 9
1
0
ns)
P120 - 79 - 10
P120NF Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.pathwaycontrol.com
Pneumatic Flow Indicator
Application – Flow Indicator; Working Pressure 5000 psig •
•
•
• •
•
• • • •
• •
• •
• •
Pneumatic paddle operated device for indication of liquid flow or no flow in piping systems, accumulators and process vessels Provides a pneumatic output to operate control systems, alarms or other operations Stainless Steel construction for use with most Liquids or Liquid interfaces Snap Acting Non-Bleed from 0 to full supply Direct mounting inside a vessel or pipe
Features and Benefits of the Pathway P120NF Durabile, Dependable 316 SS wetted components for Corrosion Resistance No Internal Seal used thus eliminating the possibility of pFew Moving Parts for Reduced Maintenance and long teExcellent Serviceability and Ease of Repair with Quick-chWide variety of Paddle Lengths to meet most application
Specifications Output: Snap Acting, Non-Bleed from 0 to Full SuppWorking Pressure: 5000 psig; 1500 psig with manual override Supply Pressure: 30 psig standard; 60 psig and 100 psig availTemperature: -40º F to +450º F Flow Indication: .75 ft/sec or less indicates no flow; 1.0 ft/secMaterials: 316 Stainless Steel Wetted components; opConnections:
Process: 2” NPT standard, 1½” NPT and flanged unitsSupply & Output: 1/4” NPT
P120NF Common Options Variety of Paddle Lengths 1½” NPT process connection
316 SS andAnnulus Plu
Benefits of ALL Pathway Control Products Personalized service and support expertise; ResponsiveTime-tested & proven design providing Dependable, Lon
rocess fluid leakage rm Performance ange replacement parts
s
ly
able
or more indicates flow tional materials available
available
304 SS flanged g for use with sediments
, On-Time Delivery g-term service
P120NF Series
m
Pneumatic Flow Indicator Dimensions:
Ordering Chart: P120NF Series: Pneumatic Flow Indicator; WP 5000 psig standard
Body Style:
2” NPT standard body 1 2 1½” NPT
Paddle Type: 1 1½” standard paddle length 2 2” paddle length 3 3” paddle length 4 4” paddle length 6 6” paddle length 8 8” paddle length 0 10” paddle length 5 Customer specified paddle length
Supply Pressure: 1 30 psig (flow rate 40 scfh at 30 psig) 2 60 psig (flow rate 25 scfh at 30 psig) 3 100 psig (flow rate 15 scfh at 30 psig)
Other: 0 No other options 2 Annulus plug 5 Customer Specified Requirements (see P120NF common opti
Option (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
Example: P120NF-
1
1
1
0
ons)
P120 - 11 - 10
PT100 Series
m
Throttling Pneumatic Level Con
Application – High & Low Liquid Level Control; W 1500•
•
•
• • •
• • • • • • • •
• • •
• •
• •
Float-actuated Throttling Pneumatic Level Control for High or Low Level control or to operate Control Valves Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid Interfaces Low Specific Gravity of .4 and above Throttling output 3 – 15 psig with 20 psig supply Direct mounting inside vessel or External Float Cage
Features and Benefits of the Pathway PT100 Durable, Dependable 316 SS wetted components for CorrosioNo Internal Seal used thus eliminating the possibility of procesFew Moving Parts for Reduced Maintenance and long term PeEconomical small-float installation Displacer options for various Pressure, Specific Gravity and InReplaceable Throttling Action Pilot Direct-acting or Indirect-acting simply by inverting the level coManual Override option for Field Testing
Specifications Output: Throttling from 3 to 15 psig Working Pressure: 1500 psig; available up to 5000 psig; 1500 psSupply Pressure: 20 psig minimum; 30 psig maximum Temperature: -40º F to +450º F Specific Gravity: 0.4 minimum; interface 0.1 differential Materials: 316 Stainless Steel wetted components; optiProcess Connection: 2” NPT standard, Ring Bolt on PT100C, 3” flaSupply/Output Connection: 1/8” NPT
PT100 Common Options Manual Override for Field Testing 316 SS & 304 SS flange connection Monel float
Stainless Steel VAnnulus Plug for
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-Time-tested & Proven design providing Dependable, Long-ter
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
trol
psig to 5000 psig
Pn Resistance s fluid leakage rformance
terface applications
ntrol unit
ig with manual override
onal materials available nged or larger
ent assembly use with sediments
time Delivery m service
PT100 Series
m
Throttling Pneumatic Level Cont
Dimensions:
Ordering Chart: PT 100 Series: Throttling Pneumatic Level Control PT100C: Ring Bolted External cage; WP 1500 psig to 3000 psig (bo
Body Style:
0 2” NPT standard body; Ring bolted body on PT100C Type:
1 316 SS standard float, WP 1500 psig, 0.4 SG min 2
3
4
Polypropylene high pressure displacer, WP 5000 psig sta3000 psig on PT100C; +180º F max temp; 0.6 SG min
Interface Polypropylene displacer, WP 5000 psig standar3000 psig on PT100C; +180º F max temp; upper fluid < .8
lower fluid > .970 SG
Customer defined SG for upper and lower fluid Interface Other:
00 No other options 02: Annulus plug 05: Customer Specific Requirements (see PT100 Common O
Option (#): Assigned # for Customer Specific Requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
rol
Example: PT100-
dy style 0)
0
1
ndard,
d, 70 SG,
02 ptions)
PT100 - 01 - 02
P110 Series Snap Acting Pneumatic Level Con
Application – High & Low Liquid Level Control; WP 1500•
•
•
• • •
• • • • • • • •
• • •
• • •
• •
Float-actuated Snap Acting Pneumatic switch for High or Low Level Control or to operate Control Valves Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .4 and above Snap Acting from 0 to full supply Direct mounting inside vessel or External Float Cage
Features and Benefits of the Pathway P110 Durable, Dependable 316 SS wetted components for CorrosioNo Internal Seal used thus eliminating the possibility of procesFew moving parts for Reduced Maintenance and long term PeEconomical small-float installation Displacer options for various Pressure, Specific Gravity and InReplaceable Snap Acting Pilot Direct-acting or Indirect Acting achieved by simply inverting thManual Override option for Field Testing
Specifications Output: Snap Acting from 0 to Full Supply Working Pressure: 1500 psig; available up to 5000 psig; 1500 psigSupply Pressure: 30 psig to 60 psig std; available 15 psig to 40 pTemperature: -40º F to +450º F Specific Gravity: 0.4 minimum Materials: 316 Stainless Steel Wetted Components; optioProcess Connection: 2” NPT standard, Ring Bolt on P110C, 3” flangSupply/Output Connection 1/8” NPT
P110 Common Options Manual Override for Field Testing 316 SS & 304 SS flange connection 15 psig to 40 psig or 50 psig to 100 psig supply
Monel float Stainless Steel Annulus Plug fo
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-Time-tested & proven design providing Dependable, Long-term
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
trol
psig to 5000 psig
n Resistance s fluid leakage rformance
terface applications
e level control
with manual override sig; 50 psig to 100 psig
nal materials available ed or larger
vent r use with sediments
time Delivery service
P110 Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
Snap Acting Pneumatic Level Control
Dimensions:
Ordering Chart: Example: P110 Series: Snap Acting Pneumatic Level Control P110- P110C: Ring Bolted External Cage; WP 1500 psig to 3000 psig (body style 0)
Body Style:
0 2” NPT standard body; Ring bolted body on P110C 0
Displacer Type: 1 316 SS standard float, WP 1500 psig, 0.4 SG minimum 1 2 Polypropylene high pressure displacer, WP 5000 psig standard,
3000 psig on P110C, +180º F max temp, 0.6 SG min
3 Interface Polypropylene displacer, WP 5000 psig standard, 3000 psig max on P110C, +180º F max temp, upper fluid < .870 SG; lower fluid > .970 SG
4 Customer defined SG for upper and lower fluid interface
Other: 00 No other options 00 02: Annulus plug 05: Customer Specific Requirements (see P110 Common Options)
Option (#): Assigned # for Customer Specific Requirements Example as Selected P110 - 01 - 00
PT101 Extended Body
m
Throttling Pneumatic Level Co
Application – High & Low Liquid Level Control; WP 150•
•
•
• • • •
• • • • • • •
• •
•
• •
Float-actuated Throttling Pneumatic Level Control for high or low level control or to operate Control Valves Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid Interfaces Low Specific Gravity of .4 and above Throttling output 3 – 15 psi with 20 psi supply Extended body provides increased reach inside the vessel Direct mounting inside vessel
Features and Benefits of the Pathway PT101 Durable, Dependable 316 SS wetted components for corrosNo Internal Seal used thus eliminating the possibility of procFew Moving parts for Reduced Maintenance and long term PDisplacer options for various Pressure, Specific Gravity and Economical small-float installation Replaceable Throttling Action Pilot Direct-acting or Indirect Acting simply by inverting the level c
Specifications Output: Throttling from 3 to 15 psi Working Pressure: 1500 psig; available to 2500 psig Supply Pressure: 20 psi minimum; 30 psi maximum Temperature: -40º F to +450º F Specific Gravity: 0.4 minimum Materials: 316 Stainless Steel wetted components; optioProcess Connection: 2” NPT standard, available 3” flanged or largeSupply/Output Connection: 1/8” NPT PT101 Common Options
316 SS and 304 SS flanged Monel float
Stainless Steel
Benefits of ALL Pathway Control Products
Personalized service and support expertise; Responsive OnTime-tested & proven design providing Dependable, Long-te
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
ntrol
0 psi to 2500 psi
ion resistance ess fluid leakage erformance
Interface applications
ontrol unit
nal materials available r
vent
-time Delivery rm service
PT101 Extended Body
m
Throttling Pneumatic Level Con
Dimensions:
Ordering Chart: PT101 Series: Pneumatic Level Control
Body Style:
0 2” NPT standard body Type:
1 316 SS standard float, 1500 psig, 0.4 SG min 2
4
Polypropylene high pressure displacer, WP 2500 ps+180º F max temp; 0.6 SG min
3 Interface Polypropylene displacer, WP 2500 psig sta+180º F max temp; upper fluid < .870 SG, lower fluid Customer defined SG for upper and lower fluid interf
Other:
00: No other options 05: Customer Specified Requirements (see PT101 comm
Option (#): Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
trol
Example: PT101-
0
1
ig standard,
ndard > .970 SG
ace
00
on options)
PT101 - 01 - 00
P111 Extended Body
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475
Snap Acting Pneumatic Level Control
Application – High & Low Pressure Control; working 1500 psi to 2500 psi •
•
•
• • • •
• • • • • • •
• •
• •
• •
Float-actuated Snap Acting Pneumatic switch for High or Low Level Control or to operate Control Valves
Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Stainless Steel construction for use with most Liquids or Liquid interfaces Low Specific Gravity of .4 and above Snap Acting from 0 to full supply Direct mounting inside vessel Extended body provides increased reach inside the vessel
Features and Benefits of the Pathway P111 Durable, Dependable 316 SS wetted components for corrosion resistance No Internal Seal used thus eliminating the possibility of process fluid leakage Few Moving parts for Reduced Maintenance and long term Performance Economical small-float installation Displacer options for various Pressure, Specific Gravity and Interface applications Replaceable Snap-acting Pilot Direct-acting or Indirect Acting achieved by simply inverting the level control
Specifications Output: Snap Acting from 0 to Full Supply Working Pressure: 1500 psig; available up to 2500 psig Supply Pressure: 30 psig to 60 psig; available 15 psig to 40 psig; 50 psig to 100 psig Temperature: -40º F to +450º F Specific Gravity: 0.4 minimum Materials: 316 Stainless Steel wetted components; optional materials available Process Connection: 2” NPT standard, available 3” flanged or larger Supply/Output Connection: 1/8” NPT
P111 Common Options 316 SS and 304 SS flanged 15 psig to 40 psig or 50 psig to 100 psig supply pressure supply
Monel float Stainless Steel vent
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-time Delivery Time-tested & proven design providing Dependable, Long-term service
P111 Extended Body
m
Snap Acting Pneumatic Level Con Dimensions:
Ordering Chart: P111: Pneumatic Level Control Switch with Extended Body
Body Style:
0 2” NPT standard body Type:
1 316 SS standard float, WP 1500 psig, 0.4 SG min 2 Polypropylene high pressure displacer, WP 2500 psig
standard; +180º F max temp; 0.6 SG min
3 Interface Polypropylene high pressure displacer, WP 2 standard; +180º F max temp, upper fluid < .870 SG; lo
fluid > .970 SG
4 Customer defined SG for upper and lower fluid InterfacOther:
00: No other options 05: Customer Specified Requirements (see P111 common
Option (#): Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
trol
Example: P111-
0
1
500 psig wer
e
00 options)
P111 - 01 - 00
6100 Series
m
Electric Vapor Pressure or Head Pressu
Application – Control Vapor Pressure or Liquid Level •
•
•
•
•
•
• • • • • • •
• •
• •
Electric pressure-actuated switch for controlling Vapor Pressure on a vessel or to provide Liquid Level Control Provides electric switch input for control systems, alarms or other operations Highly sensitive Pressure Switch is adjustable from 0” to 8” of water Liquid Static Head Switch is adjustable in a range from 2’ to 30’ of water Use on stock tanks or other vessels operating at atmospheric pressures Simple, Direct Mounting 2” NPT vessel connection
Features and Benefits of the Pathway 6100 Rugged Heavy-duty construction for long service life and low mDurable Switch Enclosure for electrical components Sensitive diaphragm provides accurate control over full range oNo floats or moving parts protruding inside the vessel Ease of installation with standard 2” NPT connection to the tankThree switches independently adjustable over the full control raField adjustable trip points
Specifications Working Pressure: Atmospheric Vapor Pressure Range Switch range from 0” to 8” of water Static Head Pressure Range Head Pressure Switch range from 2’ to 30’ of wTemperature: -20º F to +180º F Switch Rating: Vapor Pressure SPST, Mercury, 1 amp at 115 V AC, .5 amp at Static Head Pressure SPST, Mercury, 6 amp at 115 V AC, 3 amp at 2Materials: Cast iron body; aluminum stem (6100-1), stainl stainless steel switch rod; nylon reinforced nitrilProcess Connections: 2” NPT standard Electrical Connections: ½” NPT conduit standard
6100 Common Options Up to three additional switches for increased control points Light spring for more sensitive response to 15’ liquid level
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, On-timTime-tested & Proven design provides Dependable, Long-term
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
re Switch
aintenance
f device
or vessel nge
ater
220 V AC 20 V AC
ess steel stem (6100-2); e diaphragm
e Delivery Service
6100 Series
m
Electric Vapor Pressure or Head PresDimensions:
Ordering Chart: 6100 Series: Electric Vapor Pressure or Head Pressure Switch Type:
Vapor Pressure Switch 1 2 Static Head Pressure Switch
Other:
01 No other options selected 05 Customer Specified Requirements (see 6100 comm
Other Options (#) Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
sure Switch
Example: 6100-
1
01 on options)
6100 - 1 - 01
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
C300 Series External Cage for Liquid Level Controls
Application – External Cage; Working Pressure up to 5000 psig •
•
•
•
•
•
• •
• • •
• • •
• •
Use in applications where level controls are contained outside the vessel Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Choice of materials for use with most Liquids or Liquid interfaces May be used with most Pathway Liquid Level Control products or other brands with similar application Available with a variety of control connections including 1½” NPT, 2” NPT and ring bolted flange Process connections of 1” NPT, 1½” NPT, 2” NPT; Socket weld connections of 1”, 1½” and 2” on C300CS and
Features and Benefits of the Pathway C300 Series Heavy Duty, Rugged construction Choice of materials –
Ductile Iron – model C300 Carbon Steel – model C300CS 316 Stainless Steel – model C303SS
Variety of Control Connections and Process Connections avS100 Series Sight Glass may be added for Visual InspectionAvailable with Pathway Electric and Pneumatic Liquid Level
Specifications Working Pressure: 5000 psig standard; 3000 psig with rinTemperature: -40º F to +450º F Materials: A395 Ductile iron; A352-LCC steel; 31Level Control Connection: 1½” NPT, 2” NPT, or Ring Bolted connProcess Connection: 1” NPT standard, available in 1½” and
connections of 1”, 1 ½” and 2” on C300
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, OnTime-tested & Proven design providing Dependable, Long-te
C300SS
ailable Controls or separately
g bolted connection
6L (CF3M) stainless steel ection 2” NPT; socket weld CS and C300SS
-time Delivery rm service
C300 Series
m
External Cage for Liquid Level Co
Dimensions:
Ordering Chart: C300: External Cage for Level Controls – Ductile Iron C300CS: – Carbon Steel C300SS: – Stainless Steel
Level Control Connections: 1 1½” NPT 2 2” NPT 3 Ring bolted, 3000 psig max
Process Connections: 1 1” NPT standard 2 1½” NPT 3 2” NPT Socket Weld connections (C300CS & C300SS only) 6 1” Socket Weld 7 1½” Socket Weld 8 2” Socket Weld 5 Other Process Connections as requested
Other: 00 No sight glass
01 S100 Sight glass, 1½” NPT, 3000 psig max 02 03 04
S100 Sight glass, 2” NPT, 3000 psig max Connection for sight glass, 1½” NPT Connection for sight glass, 2” NPT
05 Customer Specified Requirements Option (#): Assigned # for Customer Specific requirements Example as Selected
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
ntrols
Example: C300-
2
1
01
C300 - 21 - 01
C303 Series
m
External Cage for Liquid Level C
Application – External Cage; Working Pressure 2500 p•
•
•
•
•
•
• •
• •
• • • •
• •
Use in applications where level controls are contained outside of the vessel Use on production separators, heaters/treaters, scrubbers, liquid accumulators & process vessels Choice of materials for use with most liquids or liquid interfaces May be used with most Pathway Liquid Level Control products or other brands with similar application Available with a variety of control connections including 1½” NPT, 2” NPT and ring bolted flange Process connections of 1” NPT, 1½” NPT, 2” NPT and Socket weld connections of 1”, 1½” and 2”
Features and Benefits of the Pathway C303 Heavy Duty Rugged Construction Choice of materials –
Carbon Steel – model C303CS 316 Stainless Steel – model C303SS
Variety of Control Connections and Process Connections avS100 Series Sight Glass may be added for Visual inspectionAvailable with Pathway Electric or Pneumatic Liquid Level CCustom fabrication available
Specifications Working Pressure: 2500 psig Temperature: -40º F to +450º F Materials: Carbon Steel or 316 Stainless SteeLevel Control Connection: 1½” NPT, 2” NPT, or Ring Bolted coProcess Connections: 1” NPT standard, available 1½” and weld connections of 1”, 1½” and 2”
Benefits of ALL Pathway Control Products Personalized service and support expertise; Responsive, Time-tested & proven design providing Dependable, Long
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.co
ontrols
sig
ailable ontrols or separate
l nnection 2” NPT; socket
On-time Delivery -term service
C303 Series
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
External Cage for Liquid Level Controls
Dimensions:
Ordering Chart: Example: C303CS: External Cage for Level Controls – Carbon Steel C303CS- C303SS: – Stainless Steel
Level Control Connection: 1 1½” NPT 2 2” NPT 3 Ring bolted steel, 2500 psig max 3
Process Connections: 1 1” NPT Standard 1 2 1½” NPT 3 2” NPT 6 1” Socket Weld 7 1½” Socket Weld 8 2” Socket Weld 5 Other Process Connections as requested
Other: 00 No sight glass 00
01 S100 Sight glass, 1½” NPT, 2500 psig max 02 S100 Sight glass, 2” NPT, 2500 psig max 03 Connection for Sight Glass, 1½” NPT 04 Connection for Sight Glass, 2” NPT 05 Customer Specified Requirements (such as flange size)
Option ( ): Assigned # based upon Customer Specific requirements Example as Selected C303CS - 31 - 00
22262 Cuttler Road New Caney, TX 77357 Phone 281‐354‐3699 Fax 281‐354‐4475 www.PathwayControl.com
S100 Series Sight Glass
Application – Sight Glass; WP 3000 psig at -20º F to +73º F •
•
•
•
• • •
Use in applications where visual indication of liquid level is needed Provides visual indication on Level Controls or Safety Systems May be used with Pathway External Cage Models C300 and C303 and other applications using a 1½” or 2” NPT connection Use on production separators, heaters/treaters, scrubbers, liquid accumulators & other process vessels
Features Durable body constructed of 303 SS or 316 SS Clear polycarbonate window Purchase separately or together with Pathway Pneumatic or Electric and External Cages
2” NPT
1 ½” NPT
Specifications Working Pressure: Pressures up to 3000 psig from -20º F to +73º F, 2000 psig at 2650 psig at +100º F, 2020 psig at +150º F, 1000 psig at +230Materials: 303 SS standard, 316 SS; polycarbonate lens Connections: 1½” NPT, 2” NPT
Ordering Chart: ES100: Sight Glass Body Style: 0 1½” NPT Connection 1 2” NPT
Body Type: 1 303 SS standard 2 316 SS
Lens Type: 0 Polycarbonate standard
Other: 0 No other options 5 Other special materials
Example as Selected
Level Controls
-40º F, º F max temp
xample: S100-
0
1
0
0
S100 - 01 - 00