8
PROJECTION (PLAN / ELEVATION) MEMBRANE ROOFING STUCCO CUT (SECTION) CONCRETE EARTH RIGID INSULATION BATT INSULATION WOOD BLOCKING SPRAYED INSULATION 1HR W ALL CMU BUILDING SECTION SYMBOL WALL SECTION SYMBOL ELEVATION SYMBOLS REFERENCE KEYNOTE SYMBOL A101 1 SIM DETAIL SYMBOL A101 1 SIM SIMILAR, TYPICAL, OR MIRRORED REFERENCE SIMILAR, TYPICAL, OR MIRRORED REFERENCE SPOT DIMENSIONS HEIGHT INDICATION (ABOVE RESPECTIVE GROUND FLOOR LEVEL ELEVATION) 0' - 0" WINDOW/ DOOR TAG SYMBOLS WALL TAG SYMBOL PARTITION TYPE 1,234 SF 12 ROOM NUMBER AREA OCCUPANT LOAD ROOM TAG SYMBOL Room name 101 CH= 1'-0" CEILING TAG SYMBOL HEIGHT INDICATION (ABOVE RESPECTIVE FLOOR LEVEL ELEVATION) DETAIL SHEET NUMBER SHEET NUMBER BUILDING SECTION NUMBER SHEET NUMBER DETAIL SHEET NUMBER BUILDING SECTION NUMBER SHEET NUMBER ELEVATION NUMBER A1 A101 E3/A504 DETAIL / SHEET # E3/A504 A101 1 SIM A101 1 SIM A101 1 SIM 1 A101 1t 101 DOOR TAG 1t WINDOW TAG DIVISION 00 - SHEET KEYNOTES KEYED NOTE - REFERS TO KEYNOTE LEGEND ON EACH SHEET PROJECT LOCATION ROOM 155 MILTON HALL LAS CRUCES, NM 88003 STEWART ST. INTERNATIONAL MALL E. UNIVERSITY AVE. J ORDAN RD. S. L OCUST ST PROJECT INFORMATION CLASSROOM MODIFICATION Per IBC 2015 - 304.1 OCCUPANCY CLASSIFICATION - NO CHANGE IN OCCUPANCY NO CHANGE IN OCCUPANT LOAD NO CHANGE IN EGRESS CONSTRUCTION TYPE - EXISTING SPRINKLERED: YES TOTAL GSF: 1,080 GSF PROJECT INFORMATION This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto. DESERT PEAK ARCHITECTS P.C. 1014 SOUTH MAIN STREET LAS CRUCES NEW MEXICO 88005 P. 575.528.0022 SHEET NO. SHEET TITLE ISSUE: D C B A 1 3 4 5 2 PROJECT NO. 206 - 100 G001 COVER SHEET 19-01-31 VR - CLASSROOM UNIVERSITY OF NM CAMPAS MILTON HALL, RM 155 DRAWING INDEX OWNER: UNIVERSITY OF NEW MEXICO CONTACT: NIVIA FRANCO CONSULTANTS: STRUCTURAL ENGINEERING NONE ARCHITECT: DESERT PEAK ARCHITECTS, INC 1014 SOUTH MAIN STREET LAS CRUCES, NM 88005 P. (575) 528 - 0022 CONTACT: JOSEPH FUEMMELER MECHANICAL, ELECTRICAL, PLUMBING VICINITY MAP VR - CLASSROOM RAXIS ENGINEERING 3800 N. MESA EL PASO, TX. 79902 (915) 539-2515 CONTACT: JOSE MORALES COVER G-SHEETS G001 COVER SHEET UNIVERSITY OF NM CAMPUS MILTON HALL, ROOM 155 MECHANICAL M100 MECHANICAL GENERAL NOTES M200 MECHANICAL PLAN ELECTRICAL E000 ELECTRICAL GENERAL NOTES E100 ELECTRICAL DEMOLITION PLAN E200 ELECTRICAL PLAN CIVIL ENGINEERING NONE MATERIAL LEGEND SYMBOL LEGEND 2015 INTERNATIONAL BUILDING CODE 2015 NM COMMERCIAL CODES 2012 UNIFORM PLUMBING CODE 2012 NM PLUMBING CODE 2012 UNIFORM MECHANICAL CODE 2012 NM MECHANICAL CODE 2014 NATIONAL ELECTRICAL CODE 2014 NM ELECTRICAL CODE 2009 INTERNATIONAL ENERGY CONSERVATION CODE DESIGN CODES ARCHITECTURAL A111 FIRST FLOOR DIMENSIONED PLAN & WALL PARTITION TYPES D101 DEMO FLOOR PLAN M a r k D a t e D e s c r i p t i o n

Transcript of E000 ELECTRICAL GENERAL NOTES E100 ELECTRICAL … › ... › 57 › 2019 › 01 ›...

PROJECTION (PLAN / ELEVATION)

MEMBRANE ROOFING

STUCCO

CUT (SECTION)

CONCRETE

EARTH

RIGID INSULATION

BATT INSULATION

WOOD BLOCKING

SPRAYED INSULATION

1HR WALL

CMU

BUILDING SECTION SYMBOL WALL SECTION SYMBOL

ELEVATION SYMBOLS REFERENCE KEYNOTE SYMBOL

A101

1SIM

DETAIL SYMBOL

A101

1SIM

SIMILAR, TYPICAL, OR MIRRORED REFERENCE

SIMILAR, TYPICAL, OR MIRRORED REFERENCE

SPOT DIMENSIONS

HEIGHT INDICATION (ABOVE RESPECTIVE GROUND FLOOR LEVEL ELEVATION)

0'-0"

WINDOW/ DOOR TAG SYMBOLS

WALL TAG SYMBOL

PARTITION TYPE

1,234 SF

12

ROOM NUMBER

AREA

OCCUPANT LOAD

ROOM TAG SYMBOL

Room name101

CH= 1'-0"

CEILING TAG SYMBOL

HEIGHT INDICATION (ABOVE RESPECTIVE FLOOR LEVEL ELEVATION)

DETAIL

SHEET NUMBER

SHEET NUMBER

BUILDING SECTIONNUMBER

SHEET NUMBER

DETAIL

SHEET NUMBER

BUILDING SECTION NUMBER

SHEET NUMBER

ELEVATION NUMBER

A1 A101

E3/A504

DETAIL / SHEET #E3/A

504

A101

1SIM

A101

1SIM

A101

1SIM

1

A101

1t

101 DOOR TAG

1tWINDOW TAG

DIVISION 00 -SHEET

KEYNOTES

KEYED NOTE - REFERS TO KEYNOTE LEGEND ON EACH SHEET

PROJECT LOCATIONROOM 155 MILTON HALL LAS CRUCES, NM 88003

STEWART ST.

INTERNATIONAL MALL

E. UNIVERSITY AVE.

JO

RD

AN

RD

.

S. L

OC

US

T S

T

PROJECT INFORMATION

CLASSROOM MODIFICATION

Per IBC 2015 - 304.1OCCUPANCY CLASSIFICATION -

NO CHANGE IN OCCUPANCYNO CHANGE IN OCCUPANT LOADNO CHANGE IN EGRESS

CONSTRUCTION TYPE - EXISTINGSPRINKLERED: YES

TOTAL GSF: 1,080 GSF

PROJECT INFORMATION

This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.

DESERT PEAK ARCHITECTS P.C.1014 SOUTH MAIN STREETLAS CRUCESNEW MEXICO 88005P. 575.528.0022

SHEET NO.

SHEET TITLE

ISS

UE

:

D

C

B

A

1 3 4 52

PROJECT NO.206-100

G001

COVER SHEET

19-0

1-3

1

VR

- C

LA

SS

RO

OM

UN

IVE

RS

ITY

OF

NM

CA

MP

AS

MIL

TO

N H

AL

L,

RM

155

DRAWING INDEXOWNER:UNIVERSITY OF NEW MEXICO

CONTACT: NIVIA FRANCO

CONSULTANTS:

STRUCTURAL ENGINEERING

NONE

ARCHITECT:

DESERT PEAK ARCHITECTS, INC

1014 SOUTH MAIN STREET

LAS CRUCES, NM 88005

P. (575) 528 - 0022

CONTACT: JOSEPH FUEMMELER

MECHANICAL, ELECTRICAL, PLUMBING

VICINITY MAP

VR - CLASSROOM

RAXIS ENGINEERING3800 N. MESAEL PASO, TX. 79902(915) 539-2515

CONTACT: JOSE MORALES

COVER G-SHEETS

G001 COVER SHEET

UNIVERSITY OF NM CAMPUSMILTON HALL, ROOM 155

MECHANICAL

M100 MECHANICAL GENERAL NOTES

M200 MECHANICAL PLAN

ELECTRICAL

E000 ELECTRICAL GENERAL NOTES

E100 ELECTRICAL DEMOLITION PLAN

E200 ELECTRICAL PLAN

CIVIL ENGINEERING

NONE

MATERIAL LEGEND

SYMBOL LEGEND

2015 INTERNATIONAL BUILDING CODE2015 NM COMMERCIAL CODES2012 UNIFORM PLUMBING CODE2012 NM PLUMBING CODE2012 UNIFORM MECHANICAL CODE2012 NM MECHANICAL CODE2014 NATIONAL ELECTRICAL CODE2014 NM ELECTRICAL CODE2009 INTERNATIONAL ENERGY CONSERVATION CODE

DESIGN CODES

ARCHITECTURAL

A111 FIRST FLOOR DIMENSIONED PLAN & WALL PARTITION TYPES

D101 DEMO FLOOR PLAN

Mark

Date

Description

1

1

2

EXISTING CLASSROOM

A1

D10

1

B2 D101

B1

D101

A2 D101

02 00 00.06

02 00 00.06

02 00 00.05

02 00 00.03

02 00 00.09

02 00 00.1002 00 00.08

02 00 00.03

02 00 00.10

02 41 00.03

02 41 00.0302 00 00.11

02 41 00.03

VR-LAB1

STORAGE2

STORAGE3

02 00 00.10

02 41 00.03

02 00 00.10 VR-LAB1

02 41 00.D7

VR-LAB1

02 00 00.08

02 41 00.03

02 41 00.03

02 41 00.03

02 00 00.08

02 00 00.10 02 00 00.10 02 00 00.10 02 00 00.10

02 41 00.04

02 41 00.04

02 41 00.04

02 41 00.04

02 41 00.04

02 41 00.04

02 41 00.04

02 41 00.04

02 00 00.16

02 00 00.16

02 00 00.16

02 00 00.16

02 41 00.0602 41 00.06

02 41 00.0402 41 00.04

02 41 00.04

02 41 00.04

02 41 00.05

02 41 00.05

02 41 00.05

02 41 00.05

02 41 00.05

02 41 00.05 02 41 00.0502 41 00.05

02 41 00.05

02 41 00.07

02 00 00.15

02 00 00.17

02 00 00.17

02 00 00.1802 41 00.0402 41 00.05

02 41 00.03

02 41 00.03

02 41 00.03

02 41 00.0302 41 00.03

02 00 00.11

02 41 00.03

02 41 00.03

02 00 00.10

02 00 00.08 VR-LAB1

This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.

DESERT PEAK ARCHITECTS P.C.311 NORTH MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0021

SHEET NO.

SHEET TITLE

ISS

UE

:

D

C

B

A

1 3 4 52

PROJECT NO.206-100

D101

DEMO FLOOR PLAN

19-0

1-3

1

VR

- C

LA

SS

RO

OM

UN

IVE

RS

ITY

OF

NM

CA

MP

AS

MIL

TO

N H

AL

L,

RM

155

KEYNOTE LEGEND02 00 00.03 EXISTING WALL TO REMAIN.

02 00 00.05 EXISTING BUILT-IN SHELF TO REMAIN

02 00 00.06 EXISTING ROOFING AND ROOF DRAINS TO REMAIN - LEADER PIPES TO BE

RE-ROUTED TO THE OUTSIDE OF COLUMN CHASE AS FAR AS POSSIBLE

02 00 00.08 EXISTING ELECTRICAL SWITH OR OUTLET TO REMAIN, REFER TO ELECTRICAL

SHEETS

02 00 00.09 EXISTING ELECTRICAL TO REMAIN IN THIS ROOM, NO WORK.

02 00 00.10 EXISTING DOOR, FRAME AND HARDWARE TO REMAIN , PAINT DOORS AND

FRAMES

02 00 00.11 EXISTING THERMOSTAT TO REMAIN

02 00 00.15 EXISTING LIGHT FIXTURES TO REMAIN

02 00 00.16 EXISTING FIRE SUPPRESSION SYSTEM TO REMAIN

02 00 00.17 EXISTING CEILING TO REMAIN

02 00 00.18 EXISTING EXHAUST FAN AND SWITCH TO REMAIN

02 41 00.03 REMOVE OR AMEND EXISTING ELCTRICAL/ DATA - REFER TO ELECTRICAL

SHEETS

02 41 00.04 REMOVE LIGHT FIXTURE, REFER TO ELECTRICAL FOR REPLACEMENT

02 41 00.05 REMOVE HVAC REGISTER, REFER TO MECHANICAL SHEET FOR REPLACEMENT

02 41 00.06 REMOVE SPEAKER.

02 41 00.07 REMOVE EXISTING ACOUSTIC TILE CEILING IN ITS ENTIRETY. REMOVE ALSO

ALL ASSOCIATED CEILING MOUNTED FIXTURES, GRILLS, AND EQUIPMENT-

REFER TO MEP.

02 41 00.D7 REMOVE ACT TILE BOX-OUT, HVAC DUCT TO REMAIN.

1/4" = 1'-0"D101C1 DEMO PLAN

1/4" = 1'-0"D101B1 Demo Elevation North

1/4" = 1'-0"D101A1 Demo Elevation South

1/4" = 1'-0"D101A2 Demo Elevation East

1/4" = 1'-0"D101C2 DEMO RCP PLAN

1/4" = 1'-0"D101B2 Demo Elevation West

Mark

Date

Description

2

2

2

2

2

1 11

2

2

2

A1

A101

B1

A101

B2A101

A2 A101

VR-LAB100

26 00 00.R

26 00 00.R

26 00 00.TB

01 23 00.01

01 23 00.01

01 23 00.01

26 00 00.C

STORAGE101 STORAGE

102

26 00 00.TB

26 00 00.R 26 00 00.R

26 00 00.R

26 00 00.R

26 00 00.RE26 00 00.RE

09 65 00.SF

09 90 00.P

09 90 00.PM09 65 00.SF

09 65 00.SF

09 90 00.TP

09 90 00.TP

09 90 00.TP

09 90 00.TP

02 00 00.10

02 00 00.10

02 00 00.10

26 00 00.LF

26 00 00.LF

26 00 00.LF

26 00 00.LF 26 00 00.LF

26 00 00.LF

26 00 00.LF

26 00 00.LF

09 51 00.AT22

23 00 00.D

23 00 00.D

23 00 00.D

23 00 00.D 23 00 00.D

23 00 00.D

23 00 00.D

26 00 00.LF

26 00 00.PD

02 00 00.15

02 00 00.17

26 00 00.TB26 00 00.R

26 00 00.C

09 51 00.AT22

09 51 00.AP1

02 00 00.16

26 00 00.C

02 00 00.08

26 00 00.C

26 00 00.R 26 00 00.C

09 21 16.TP

09 83 11.AW

26 00 00.JB

26 00 00.JB

23 00 00.TM26 00 00.R

26 00 00.TB

26 00 00.JB

26 00 00.RE

26 00 00.RE

26 00 00.TE

02 00 00.10

02 00 00.10

02 00 00.10

02 00 00.10

02 00 00.10

26 00 00.S

09 21 16.HTYP. FOUR

02 00 00.08

This document may not be reproduced in whole or part by any means, electronic or otherwise without the explicit written permission of Desert Peak Architects P.C.. All reports, plans, specifications, computer files, field data and other documents and instruments prepared by the Architect as instruments of service shall remain the property of the Architect. The Architect shall retain all common law, statutory, and other reserved rights, including the copyright thereto.

DESERT PEAK ARCHITECTS P.C.311 NORTH MAIN STREETLAS CRUCESNEW MEXICO 88001P. 575.528.0021

SHEET NO.

SHEET TITLE

ISS

UE

:

D

C

B

A

1 3 4 52

PROJECT NO.206-100

A101

FLOOR PLAN

19-0

1-3

1

VR

- C

LA

SS

RO

OM

UN

IVE

RS

ITY

OF

NM

CA

MP

AS

MIL

TO

N H

AL

L,

RM

155

KEYNOTE LEGEND01 23 00.01 RECOMMENDED CLEARANCE AT DOOR

02 00 00.08 EXISTING ELECTRICAL SWITH OR OUTLET TO REMAIN, REFER TO ELECTRICAL

SHEETS

02 00 00.10 EXISTING DOOR, FRAME AND HARDWARE TO REMAIN , PAINT DOORS AND

FRAMES

02 00 00.15 EXISTING LIGHT FIXTURES TO REMAIN

02 00 00.16 EXISTING FIRE SUPPRESSION SYSTEM TO REMAIN

02 00 00.17 EXISTING CEILING TO REMAIN

09 21 16.H 5/8" GWB SECURED TO EXISTING WOOD FRAME. PAINT BACK SIDE BLACK.

TEXTURE AND PAINT FRONT TO MATCH WALL

09 21 16.TP PATCH,TEXTURE AND PAINT ALL WALLS - COLOR SELECTED BY OWNER

09 51 00.AP1 ACOUSTICAL PANEL BOX AROUND EXISTING DUCT

09 51 00.AT22 SUSPENDED TILE CEILING, 2X2 - REFER TO ROOM FINISH LEGEND FOR TILE

DESIGNATION

09 65 00.SF SHEET FLOORING AND RUBBER BASE THROUGHOUT

09 83 11.AW ACOUSTIC WALL SYSTEM

09 90 00.P PAINT ALL WALLS, TYP

09 90 00.PM PATCH AND PAINT ALL WALLS, TYP

09 90 00.TP TEXTURE AND PAINT ALL WALLS, TYP

23 00 00.D HVAC DUCTS - REFER TO MECHANICAL

23 00 00.TM THERMOSTAT-REFER TO MECHANICAL

26 00 00.C CONDUIT, PAINT TO MATCH WALL - REFER TO ELECTRICAL

26 00 00.JB BANK BOX, PROVIDE BOX EXTENSION - REFER TO ELECTRICAL

26 00 00.LF LIGHT FIXTURE - REFER TO ELECTRICAL

26 00 00.PD ELECTRICAL POWER DROP - REELCRAFT

26 00 00.R ELECTRICAL RECEPTACLE - REFER TO ELECTRICAL

26 00 00.RE ELECTRICAL RECEPTACLE, PROVIDE BOX EXTENSION - REFER TO ELECTRICAL

26 00 00.S ELECTRICAL SWITCH - REFER TO ELECTRICAL

26 00 00.TB TELECOMMUNICATION OUTLET - REFER TO ELECTRICAL

26 00 00.TE TELECOMMUNICATION OUTLET, PROVIDE BOX EXTENSION- REFER TO

ELECTRICAL

1/4" = 1'-0"A101C1 FIRST FLOOR PLAN

1/4" = 1'-0"A101C2 FIRST FLOOR REFLECTED CEILING PLAN

1/4" = 1'-0"A101B1 ELEVATION NORTH

1/4" = 1'-0"A101A1 ELEVATION SOUTH

1/4" = 1'-0"A101B2 ELEVATION WEST

1/4" = 1'-0"A101A2 ELEVATION EAST

Mark

Date

Description