Users Energy Distribution Company Admin Office Web Server

description

 

Transcript of E emb brochure

Page 1: E emb brochure

Users

Energy DistributionCompany Admin Office

Web Server

Page 2: E emb brochure

1- The Overhead and Manpower cost is more.2- The system failure is more.3- There is no systematic way of Maintenance, distribution and Collection of revenue.4- Door to door meter reading .5- Consumer being bored for registering calls and waiting for lineman.6- Individual consumer attend office personally or telephonically.7- If current fails due to Overload then the technician need to come to for resetting.8- For one consumer’s problem, the other consumers of the area suffers.

Page 3: E emb brochure

One transformer unit is located by the Department to control the power supply to a group of consumers of a particular locality. It maintains the consumer status of that area. By the introduction of energy monitor system, the following facilities can be obtained which will gear up the preservation of the existing transformer, which are frequently attended being defective and trouble some. 1. Power out put can be limited.2. Less pressure on the transmitter.3. Consumer cannot alter the load of energy without the knowledge of the authority.4. Over-loading and the misuse of energy can be checked and controlled systematically.

Page 4: E emb brochure

This picture clearly envisages the internal arrangements of the e-EMB.Monitor: This is meant for monitoring the individual reading of the consumer .Power control box: This shows the individual / group power box separately arranged and fixed for each consumer / group.Modem: This is called modem, which will transfer all the data to the mini-exchange.Receive box: This will indicate all the matters received for the mini- exchange Modem receiver box: This will feed all the data to the modem.Power box: This will control and supply the power to different branches.

Page 5: E emb brochure

SPECIFICATIONa) THIS IS GSM TECHNOLOGY BASED TELEMETERING SYSTEM VIA GPRS & INTERNET

THROUGH POWER MANAGEMENT SOFTWARE & OWN SERVER.

b) 900 MHz based system

c) I/P can be 8/16/32 etc

d) Every 30 minutes reading transfer (can be changed).

e) Nonvolatile static RAM for accidental data storage.

f) Consumer demand can be configured any time.

g) Line connection & disconnection from central office.

h) Over load trip & auto reset

i) Single phase & Maximum 30Amp capacity per consumer

j) LCD display in DDP unit for local monitoring.

k) Powerful antenna for distance coverage.

l) Totally sealed unit with 4 compartments (Motherboard with GPRS card Slot, RS-485, SMPS and Indivisual MeterBoard).

m) Both PostPaid and PrePaid.

Page 6: E emb brochure

V- VoltageA- AmpereLA- Load AssignON/OFF/OT- StatusKHW- Kilo Watt HourW- Watts

Page 7: E emb brochure

INDIVIDUAL CONSUMER CONNECTION FROM EXISTING POLE Individual power connection isgiven to each house of theconsumer from this nearestelectric pole. All these lineshave separate adjustment inside the energy monitor box fixed with the electric pole.

The energy monitor box will indicate always the clear status of electric connection provided separately to each individual house. Every house is treated as a single unit. In every consumer premises, there is provision of separate cut-out and indicator are to be maintained and be replaced by the individual customer on own cost.

Page 8: E emb brochure

PICTORIAL DIAGRAMS ARE SHOWN WITH A SHORT FOOT NOTE FOR INSTANT PERUSAL AND EASY UNDERSTANDING

e-EMB (e-ENERGY METERING BOX)

This is a portable box of size 16x 14 x 4On the Electric pole, on the Roadside, a group of consumers’ units are set up in the e-EMB. The box contains connections and lining for each consumer with a codified number meant for each consumer. There is also provision for connecting to 8 consumers,16 consumers, 32 consumers and 64 consumers in one e-EMB.It works as mini-energy-exchange.

This box has the provision of controlling individual consumer units and treatedas controlling unit for all. This box is fed by Mini-Energy-Exchange that is called the mother-feeding unit. It also contains a specially devised circuit that helps to record reading in a LCD screen.

Page 9: E emb brochure

This box is made in specific materials with unique arrangements. This is rain proof as well as heat proof to protect it from rainfall and sunshine. As the boxes are fitted in the poleunder open sky, there is everypossibility of its damage by rain and sunshine. It is provided with lock and key system to prevent mishandling. The internalconnection is tightly arranged,not to be disturbed by the stroke of stone or thrashes. The boxis not easily breakable. It is also ant-proof and will not rusteasily though exposed in openatmosphere.

Page 10: E emb brochure

COOLING FAN: The cooling fan will be inside the e-EMB in order to save the components from excess heating.

TEMPERATURE CONTROLLED REGULATING SYSTEM:The function of this unit is to run the fan during increased temperature and will be off during cool weather.

SAFETY MEASURE:Customer-wise fuse system will be provided in the telemeter box, so that for defect in one consumer unit, the entire group will not be affected. This system is to protect the unexpected hazards that may lead to damage to life or any other appliances.

Page 11: E emb brochure

CONSUMER FRIENDLY SUPPLY:There will be no power cut as prevailing now a days, but there will be proportionate power supply as per the state power stock. For example , suppose a consumer is of 3 Kw load, and there is power shortage for various reasons beyond control, in that case the consumer will get less wattage , but will not remain in complete darkness for hours or days. The supply may be of 2 Kw or 1.5 Kw and so on. depending on availability.

INTIMATION TO CONSUMER:

Any information regarding consumption, supply, revenue or any other related information will be available on NET /Mobile.

Page 12: E emb brochure