DynaScan DS1016 Quickstart Guide

16
Ver.1.01 DS1016 Quick Start Guide 1 Hardware Quick Start 1.1 Location of Control Box The following drawing is the top view of control and power space allocation under the display. Maintenance / Power Outlet Maintenance /Air Con. tube Power Control / Space DVI&RS-232 / AC/DC Maintenance Front Side Open here Open here Open here Lock Lock Maintenance #A #B #C #1 #2 #3 #4 #5 #6 Maintenance / Power Outlet Maintenance /Air Con. tube Power Control / Space DVI&RS-232 / AC/DC Maintenance Front Side Open here Open here Open here Lock Lock Maintenance #1 #2 #3 #4 #5 #6 #A #B #C There are 3 external doors available to open. The computer /player with DVI output can be put in the spare space (#1), and connect to DVI & RS-232 panel (#5). Copyright © 2008 DynaScan Technology Corp. 1

description

DynaScan DS1016 Quickstart Guide

Transcript of DynaScan DS1016 Quickstart Guide

Page 1: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

1 Hardware Quick Start 1.1 Location of Control Box

The following drawing is the top view of control and power space allocation under the display.

Maintenance /Power Outlet

Maintenance /Air Con. tube

Power Control /

Space DVI&

RS-2

32/

AC/D

C

Maintenance

Front Side

Open here Open here

Open here

Lock

Lock

Maintenance

#A

#B

#C#1

#2

#3

#4

#5

#6

Maintenance /Power Outlet

Maintenance /Air Con. tube

Power Control /

Space DVI&

RS-2

32/

AC/D

C

Maintenance

Front Side

Open here Open here

Open here

Lock

Lock

Maintenance

#1

#2

#3

#4

#5

#6

#A

#B

#C

There are 3 external doors available to open. The computer /player with DVI output can be put in the spare space (#1), and connect to DVI & RS-232 panel (#5).

Copyright © 2008 DynaScan Technology Corp. 1

Page 2: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

1.2 Power Input and Consumption

L

N

L

NFor Display

For Air Conditioner You will see the terminal block when you open the

maintenance door (#2). Please tightly secure the

power line on the terminal block as shown.

GGround

The power control box has two AC power cables. One

is for the display with input power 25A@220Vac

(maximum), the other is for the air conditioner with

input power 19A@220Vac (maximum). We suggest

that you install the each power line on the 40A

Breakers separately.

N (Black)L (RED)

Ground (Green)

Copyright © 2008 DynaScan Technology Corp. 2

Page 3: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

1.3 Air Conditioner Power Connection 2. Secure the 7 wires with marks from power control

base as shown below.

15A Circuit Breaker Power Switch for air con. A

RJ-45 network cable adapter

Red line from power control base (A/C A L)

2 black lines from power control base (A/C A N)

There are two wiring boxes fixed under the top in the

air con. base, and the below one locates on the left for

air con. A connection.

1. Secure the wires marked as below from the

power control base on the terminal block. (3

power cords for air con. A)

Function Air con. B Power Color L (Red) N (Black) Mark A/C B L A/C B N

Function Air con. A control Color 1 (White) 2 (Black)(2 Lines)Mark A/C A 1 A/C A 2

Function Air con. B control Color 1 (White) 2 (Black) Mark A/C B 1 A/C B 2

3. Turn on the power switch of air con. A after finishing the wiring.NOTE: Please be sure to keep the power switch of air con. A on when operating to cool the power control base

chamber.

CAUTION: If the power switch of air con. A were not on, the power control base chamber will be over-heated.

Copyright © 2008 DynaScan Technology Corp. 3

Page 4: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

1.4 Video and Control Connection

You will see the panel as you open the DVI & RS-232 door (#5). Please connect DVI out and COM port from the

computer to the panel respectively. The Monitor System software from DynaScan can support the display mode

control, e.g. brightness, spin speed and offset etc., and read the current temperature of the drum.

COM Port DVI Port

Voltage Meter AC/DC Converter

Copyright © 2008 DynaScan Technology Corp. 4

Page 5: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

1.5 Display Operation

1.5.1 Power ON/OFF Steps

1. Turn ON/OFF the power switch for the display.

2. Turn ON/OFF the air con. switch for air conditioner.

CAUTION: Please do not change the default settings of inverter and thermal switch for safety.

Panel of Inverter

Air Con.

Power

Thermal Switch

Copyright © 2008 DynaScan Technology Corp. 5

Page 6: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

2 Function / Maintenance Introduction2.1 Monitor System Operation

2.1.1 Start Program Follow the path (Program Files -> DynaScan Monitor System 2007 -> MonitorSystem2007); an icon shall appear at the right of the task bar near the clock. Right click on this icon, and then choose <Restore> to activate

the operation window.

As action 1, right click the mouse at the display list to

show the “Pop Menu”. Press “New” to show the

“Append” dialogue as action 2. Enter the name and

model of the display and the RS232 Port used into the

“Machine Data” field in the “Option Page”, then click

<Append>. A new display is now added.

Copyright © 2008 DynaScan Technology Corp. 6

Page 7: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

2.1.2 Simple Operation Provide functions to operate the display.

NOTE: For more instruction of Monitor System 2007, Please refer to the Monitor System 2007 User Manual.

Spin Speed:

Set spinning speed for the image of the displayer.

Tick <Fixed> and the image of the displayer shall stop

spinning. Pull the bar of the <Stage> from low to high;

the spinning speed shall increase accordingly.

Brightness:

Brightness adjustment.

Set the degree of brightness of the displayer. Different

types of displayer have different levels of brightness.

Power On / Off:

Turn on/off the power of the displayer manually.

Power On: Turn on the display.

Power Off: Turn off the display.

Caution: This action shall cause the “Schedule” to pause.

Copyright © 2008 DynaScan Technology Corp. 7

Page 8: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

2.2 Unpacking

There are two wooden crates. One is display, and the other is the base and Air con.

Step 1. Disassemble the wooden top cover, and side covers. Step 2. We suggest you lift the display and move to the installation site.

Display

Step 3. Disassemble the wooden top cover, and side covers.

Step 4. We suggest you lift the base and move to the installation site.

Base

Copyright © 2008 DynaScan Technology Corp. 8

Page 9: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

2.3 Move the Machine

Lift the Display

If you want to lift the display, you must disassemble the display with the base first. To lift the display, you need to install the eyebolt on the triangle hanging frame and use the lifting device.

NOTE: For more instruction of Display lifting, please refer to the complete version

user manuals provided in the Disc.

Move the display

If you want to move the display, you must use a hand pallet truck.

Caution: When you use a hand pallet truck to move the display, please move it carefully and slowly.

Caution: Please be sure that the screws and connecting pipes and cables between the display and the air

conditioner base are removed and disconnected completely.

Caution: Please make sure that you fasten the eyebolt firmly, or the eyebolt

may not carry the display’s weight and the display will fall down

Copyright © 2008 DynaScan Technology Corp. 9

Page 10: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

2.4 Ground Mounting

For Safety Reason, you must do the ground mounting to fasten the display onto the ground.

Step1. Use Type J, M20*630mm foundation screw inter to the ground in advance, with the drawing shown below.

Front Side

NOTE: Please Ensure that the tension strength

of each foundation screw with concrete

ground mount surface is no less than

2500kg. The ground mounted work must

be done by civil engineering specialists.

After the work is complete, we advise that

the reliability of it be checked and

approved by authorities concerned in

your area for safety purpose. The Ground

must be concrete base.

Conduit

Power Cord Hole

Front Cover

Copyright © 2008 DynaScan Technology Corp. 10

Page 11: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

Type J, M20*630 foundation screw

Step2. Move the display to the preferred place and use the

nuts to fix it. Tighten the M20 screws to fix the ground-fixing

block with the display.

Copyright © 2008 DynaScan Technology Corp. 11

Page 12: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

3 Reference3.1 Specifications

Model DS1016 LED Type Lamp

Pitch (H x V) 2.0mm x 2.0mm

Resolution 1530x 768 x 1 screen (Full wrap)

Brightness > 7500 cd/

Color 16.7 millions

Contrast Ratio > 5000 : 1

Screen Size (Diagonal) 75” Diagonal x 3

Total Display Area (W x H) 3.06 m x 1.54 m x 1

Viewing Angle(H x V) >170 x 60o o

Physical Dimension (D x H) 1.14m x 3.36m

Physical Weight 1080Kg

Power Supply 1 ,200~240 VAC, 50/60 Hz, 40A

Cooling System Power Supply 1 ,200~240 VAC, 50/60 Hz, 40A

Color Spectrum Red: 630nm Green: 525nm Blue: 470nm

Safe Ambient Temperature From -20 to 45 C o o

Copyright © 2008 DynaScan Technology Corp. 12

Page 13: DynaScan DS1016 Quickstart Guide

Ver.1.01 DS1016 Quick Start Guide

3.2 Legal Notices Intel lectual property; limited license to users The hardware and software of our products are protected by copyr ight , t rademark, patent , and/or other intel lectual property laws, and any unauthor ized use of the software, t rademarks containing herein may violate such laws and the software l icense agreement. Except as expressly provided herein, DynaScan and i ts suppl iers do not grant any express or impl ied r ights to use any product re lated hardware and software. DynaScan is registered trademark of DynaScan Technology Corp. in R.O.C and\or other countr ies. Microsoft is registered trademark of Microsoft Corp. Moonl ight is registered trademark of Moonl ight cordless Ltd. IBM is registered trademark of IBM Corporat ion. Other t rademarks are trademarks of their respect ive owners. Disclaimer Speci f icat ions and information contained herein are furnished for informational use only. Revisions are periodically made to the information herein; these revisions will be incorporated in later editions. Improvements or changes in the products or the programs described may be made at any time and are subject to change without notice, and should not be construed as a commitment made by DynaScan. This manual could include mistyping or typographical errors. DynaScan assumes no responsibility or liability for any errors or inaccuracies that may appear in this manual. Exclusion of Damages:

DynaScan Technology Corporat ion’s l iabi l i ty is l imi ted to the cost of repair or replacement of the product.

DynaScan Technology Corporat ion shal l not be l iable for : 1. Damages to other property caused by any defect in the product, damages based upon

inconvenience, loss of use of the product, loss of t ime, loss of prof i ts , loss of business opportuni ty, loss of goodwi l l , interference with business relat ionships, or other commercial loss, even i f advised of the possibi l i ty of such damages.

2. Any other damages, whether inc idental , consequent ia l or otherwise. 3. Any cla im against the customer by any other party.

Copyright © 2008 DynaScan Technology Corp. 13

Page 14: DynaScan DS1016 Quickstart Guide

3.3 Disposal Notices

Do not dispose of electrical appliances as unsorted municipal waste,

use separate collection facilities. Contact your local government for

information regarding the collection systems available. If electrical

appliances are disposed of in landfills or dumps, hazardous substances

can leak into the groundwater and get into the food chain, damaging

your health and well-being. When replacing old appliances with new

one, the retailer is legally obligated to take back your old appliances for

disposal at least for free of charge.

NOTE: Please refer to the complete version user manuals provided in the Disc for full safety and operation info of the displays.

Copyright © 2008 DynaScan Technology Corp. 14

Page 15: DynaScan DS1016 Quickstart Guide

MEMO

Copyright © 2008 DynaScan Technology Corp. 15

Page 16: DynaScan DS1016 Quickstart Guide

Copyright © 2008 DynaScan Technology Corp. 16