Durai Swamy, Ph.D. Intelligent Energy June 12th, 2008 · (S/C=6, 70 psig) Reformate Composition of...
Transcript of Durai Swamy, Ph.D. Intelligent Energy June 12th, 2008 · (S/C=6, 70 psig) Reformate Composition of...
Development and Demonstration of a New Generation High-Efficiency 1-10 kW Stationary PEM Fuel Cell Power System
Durai Swamy, Ph.D.
Intelligent Energy
June 12th, 2008
This presentation does not contain any proprietary, confidential, or otherwise restricted information
Project FC39
OverviewTimeline
−Start: July 2007−End: July 2010−25% complete by 4/08
Budget−$4.4 million budget−50% DOE cost share
−$322K received FY07−$450K projected for FY08
Barriers
Partners−Intelligent Energy, Inc. (lead)−Intelligent Energy, Ltd.−University of South Carolina−California State Polytechnic
University, Pomona−Sandia National Labs
Targets Project DOE 2011
Electrical Eff. 40% 40%
Overall Eff. > 70% 80%
Durability 40,000 hrs 40,000 hrs
Capital Cost $400 / kW $750 / kW
ObjectivesDevelop and demonstrate a PEM fuel cell based stationary power system that provides foundation for commercial, mass produced units that address identified technical barriers
• Technical objectives−40% electrical efficiency (fuel to electric energy
conversion)−70% overall efficiency (fuel to electric energy + usable
waste heat energy conversion)−Potential for 40,000 hour life−Potential for $450/kW
• Topic 7A – International Partnership for a Hydrogen Economy (IPHE)−Engage international partners−Demonstration phase in an IPHE country other than USA
Milestones
Milestone: Evaluation of adsorbent materials for use in adsorption enhanced reformer completed; initial tests with high pressure membrane reformer completed
Go/No-Go Decision: Validation of hydrogen generation and fuel cell performance improvements demonstrating the viability of achieving a 40% electrical efficiency for the system will be complete. A Go decision will be followed by proceeding to development and testing of a prototype PEMFC power system.
July 2008
January 2008
Contract signed and project launchedJuly 2007
Milestone or Go/No-Go DecisionMonth/Year
ApproachOpen architecture – high purity hydrogen interface between fuel cell, fuel processor
−Increase cell voltages−Increase
hydrogen generation thermal efficiency−Decrease
parasitic loads0.60
0.65
0.70
0.75
0.80
0.85
0.90
60% 65% 70% 75% 80% 85% 90%H2 Generation Eff, %
Ave
rage
Fue
l Cel
l Vol
tage
, V/c
ell
15% Parasatic Power10% Parasatic Power5% Parasatic Power
CHP A
CHP B
CHP C
Design points above line
exceed 40% efficiency
Design points below the linedo not achieve 40% efficiency
Note: H2 generation efficiency is for high purity hydrogen not reformate. A typical 85% efficient reformate and 75% anode fuel utilization would imply a 64% H2 generation efficiency.
ApproachFuel cell stack and system
−Improved flow field design−Fluid flow modeling−Advanced MEA design−Diffuser optimized for water
management−Advanced bipolar plate
materials −Reduced air pressure
requirements−Pressed plate architecture to
address cost−Optimized air delivery design−Optimized power management
design & configuration
Hydrogen generationEthanol reforming - Two platforms in development−MesoFuel advanced membrane
reactor (< 2 kWe)− Increase reactor pressure− Thermal integration
improvements
−Hestia with rapid cycle PSA (> 2 kWe)−With 100mV fuel cell voltage
improvement, efficiency target can be reached with optimization of current Hestia design
−With 20mV fuel cell voltage improvement, efficiency target can be reached with integration of CO2 adsorption (AER) into Hestia process
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 1.10
Current Density/A cm-2
Cell
Voltage/V
0
14
28
42
56
70
84
98
112
126
140
Cell
Pow
er/
W
Combined technology developmentsBenchmark
Technical AccomplishmentsPEMFC – single cell performance improvements
Improvements show cumulative effects of new MEA, cooling architecture and diffuser material
Technical AccomplishmentsPEMFC – reduced system parasitic loads
High efficiency DC/DC converter development• High voltage converter for compressor operation• Low voltage converter for battery charging and
auxiliaries• Data indicate efficiencies of 95+% may be possibleCurrent work and next steps• Test the converter in a system• Test self-start operation
0%
10%
20%
30%
40%
50%
60%
70%
0 2 4 6 8 10 12net output power/kW
effic
iency
LH
V H
2
Baseline SystemBaseline StackJan 08 SystemJan 08 StackApril 08 SystemApril 08 Stack
Net Electrical Efficiency
Gross Electrical Efficiency
Technical AccomplishmentsPEMFC – forecast fuel cell system performance improvement
Data show potential system efficiencies based on:•Improved fuel cell performance •Reduced compressor power•Unregulated DC voltage output
57.4% efficient at 6kWe (baseline = 50%)
Technical AccomplishmentsHestia reformer - new reactor design
• Designed for ease of manufacture, assembly• Reduced pressure drop across combustor/flue gas path• Enhanced thermal integration• Streamlined balance of plant• Increased operating pressure / H2 recovery• Status−Fabrication, assembly completed fall 2007−Testing initiated December 2007−Initial ethanol tests performed January 2008−Preparing for next phases of tests April 2008
Technical AccomplishmentsHestia reformer – initial results
−New reformer reactor has been tested as standalone system, using simulated PSA off-gas as heat source−Results to left show expected H2
generation efficiency b d f based on reformer test results + potential PSA recoveriesrecoveries
Technical AccomplishmentsMeso reformer – performance mapping of single module completed
T = 575 – 640 CPfeed = 70 – 175 psigPprod = 5 psig – 500 mbarS/C = 4.5
Metric TargetStatus(4/15/08)
H2 purity > 99.9% > 99.9%
Thermal efficiency > 70% 65 - 67%
H2 production, slpm
5-6(10 module)
0.6 @ 65 -67% efficiency(single module)
H2 flux, sscm/cm2 15-20 15-17
Technical AccomplishmentsMeso reformer – summary of flux and efficiency
•Purity > 99.99%•Also demonstrated methane reforming•Stable operation achieved
Technical AccomplishmentsAER – dynamic model for AER process steps (U South Carolina)
PSA model adapted to PSA model adapted to include reforming reactions
Model has informed experimental apparatus designs
• Bed sizing• Cycle times• Temperatures• CO2 breakthrough• Purge gas requirements
Status: Calibrating model with experimental results. Model breakthrough times are similar to test data
– include reforming reactions– Model has informed experimental apparatus
designs• Bed sizing• Cycle times• Temperatures• CO2 breakthrough• Purge gas requirements
– Status: Calibrating model with experimental results. Model breakthrough times are similar to test data
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
0 30 60 90 120 150 180 210 240
TOS [min]
Volu
me
frac
tion
CH4N2H2COCO2
All gases but CO2 get instantly purged out of the bed
Methanation with H2 and sorbed CO2
AER
N2
Pur
ge
H2+
Ste
am
TOS, min
Technical AccomplishmentsAER –experimental proof of concept
The above chart demonstrates four consecutive AER cycles successfully demonstrated on small reactor with ethanol‐water mixture (S/C=6, 70 psig)
Reformate Composition of 33 wt.% SR-1 / Pural MG70 with 20% K2CO3
0
20
40
60
80
100
0 30 60 90 120 150 180 210 240TOS [min]
Con
cent
ratio
n [v
ol.%
]
H2CH4COCO2
N2
H2+H2O EtOH+H2O
N2 N2 N2
EtOH+H2O EtOH+H2OH2+H2O H2+H2O H2+H2O
− Chart shows consecutive cycles with Ethanol on larger reactor (S:C =4.5)
− Table below is total cycles on larger reactor through May 2008
− e
Technical AccomplishmentsAER – full scale experimental results with integrated combustor
−Currently evaluating cycle timing, temperature profiles, heat balance
−Reactor and test stand specifications:−Natural gas or ethanol−1 to 5 kWe−Regenerate with nitrogen,
steam or other−All heat provided by
combustion−Measure H2 production
enhancement as well as CO2
breakthrough in bed
Technical AccomplishmentsAER – novel adsorbent materials (Cal Poly Pomona)
−Amorphous magnesium oxide (MgO) ambigel and xerogel materials
−Significant potential for increased adsorption capacity
−Status:−Several batches synthesized and
currently being analyzed by IE−Further batches planned
SEM of monolithic MgO aerogel(left) and xerogel (right)
Technical AccomplishmentsSystem level performance assessment (Sandia)
• Collaboration with Sandia National Labs to assess potential performance of possible system architectures
• Part of Sandia’s contribution to IEA-HIA Task 18
e-Load
ReformerSeparation
(PSA)
Batt
PowerManage
FCHeatRecovery
H2 Storage
Heat Load
Retentate
SyngasFuelH2OAir
AirQ
H2
H2
We
We Flue
KO water
Flue
• Status (4/15/08):• Collaboration launched in March 2008• System model adapted to capture IE’s
approach• Initial results show 35% fuel-to-
electric efficiency based on historical Hestia reformer data, new fuel cell data and parasitic power losses
• Next steps• Consider other system architectures• Continue to update models with
experimental data• Form basis for go/no-go in July 2008
Future WorkFY08
• Go/No-Go (July 2008): Determine system architecture leading to reaching technical objectives• Go decision will be followed by proceeding to development
and testing of a prototype PEMFC power system
FY09• Milestone (January 2009): Complete engineering
design of integrated power system• Milestone followed by in-house system testing
• Go/No-Go (July 2009): Validation of the prototype power system’s ability to meet performance targets will be complete• Go decision will be followed with continuing to the field
demonstration of this system
Summary −Approach: Develop portfolio of technologies in Project Year 1 (Jul-07 – Jul-08) to determine best architecture for meeting DOE objectives for stationary fuel cell power
−Partners−IE in US (lead) & UK−U of South Carolina−Cal Poly Pomona−Sandia Nationa Labs
−Future work: Down-select technologies then engineer, test and demonstrate new generation PEMFC power system
System BaselineStatus(4/15/08)
Fuel cell system efficiency
50% 57%
Hestia hydrogen generator
Sophisticated mechanical design
Design for manufacture and assembly
Mesohydrogen generator efficiency
50% 65 – 67%
Adsorption enhanced reformer
Concept on paper
Experimental proof of concept
Summary of technical progress highlights