Index

DESIGN INFORMATION AND MATERIAL SPECIFICATIONS .............................................................................. 2STEEL LINTELS ............................................................................................................................................................ 3-5DUR-O-SPLICE ................................................................................................................................................................ 6SHELF ANGLE & OCM MASONRY ANCHOR .......................................................................................................... 7DOVETAIL AND CHANNEL ANCHOR SYSTEMS ............................................................................................... 8-9TIES, ANCHORS AND VENEER ANCHORS ......................................................................................................10-13SEISMIC TIES AND ANCHORS ............................................................................................................................14-16REBAR POSITIONERS AND OTHER PRODUCTS ........................................................................................... 17-18STONE ANCHORS ........................................................................................................................................................ 19MOVEMENT CONTROL PRODUCTS.................................................................................................................20-21MOISTURE CONTROL PRODUCTS ...................................................................................................................22-24GLASS BLOCK MASONRY ACCESSORIES .............................................................................................................25SINGLE WYTHE SYSTEMS .........................................................................................................................................26MULTI-WYTHE NON-ADJUSTABLE SYSTEMS ..............................................................................................27-28MULTI-WYTHE ADJUSTABLE SYSTEMS ................................................................................................................29SEISMIC JOINT REINFORCEMENT.................................................................................................................... 30-33RANDOM / RUBBLE STONE SYSTEM .....................................................................................................................34DUR-O-WAL SPECIFICATIONS .......................................................................................................................... 35-36BRACE RITE® SYSTEM ...........................................................................................................................................37-39RESTORATION ANCHORS .........................................................................................................................................40DUR-O-WAL SAFETY INFORMATION .................................................................................................................... 41

Product Page# 6 Wide Flange PVC Control Joint .............20# 8 Wide Flange PVC Control Joint .............21#12 Wide Flange PVC Control Joint ............21#6 Wide Flange Rubber Control Joint .........20Adjustable Dur-O-Tab with Restraint Bar.....34Adjustable Rectangular Cavity Wall Ties .....12Adjustable Rectangular Tab Tie w/ Masonry Strap Anchor ........................ 11Adjustable Seismic Wall Eye Plate ..............15Adjustable Speed Set Veneers Ties ............10Askew Bolt .....................................................7Backing Plate...............................................38Brace Clip ...................................................38BRACE-RITE HD Pipe Brace ......................37 BRACE-RITE HD Long Pipe Brace .............37BRACE-RITE Regular Pipe Brce.................37Brick Replacement Anchor ..........................40Cell Vents ....................................................23Channel Anchor ............................................9Channel Anchor Slot ..................................8, 9Channel Anchor Triangular Ties ....................9Coil Anchor ..................................................39Column Anchor ............................................12Column Anchor Weld-On .............................13Column Flange Ties.....................................13Continuous Channel Anchor Slot...................9Continuous Rectangular Tab Tie (CRT) .......28Copper Coated Thru-WallFlashing ..............22Copper Fabric Thru-Wall Flashing ...............22Copper Kraft Duplex Flashing .....................22Corregated Wall Ties ...................................13DCF Flashing Tape ......................................22DCF Thru-Wall Flashing ..............................22Dovetail Anchor .............................................8Dovetail Anchor Slots ....................................8Dovetail Triangular Ties Anchor .....................8Dovetail Triangular Ties Series ......................8Drip Edge Flashing ......................................23Dur-O-Barrier Tapes ....................................25Dur-O-Barrier Thru-Wall Flashing ................23Dur-O-Eye ...................................................29Dur-O-Fibar .................................................18Dur-O-Flex Friction Pinning Anchor .............40Dur-O-Splice Coupler ...................................6

Product PageDur-O-Splice End Anchor .............................6Dur-O-Splice Tapered Threaded Rebar .........6Dur-O-Splice Thread Protector ......................6Dur-O-Stop ..................................................18Dur-O-Tab ....................................................28Fil-Stop ........................................................18Floor Bracket ..............................................38Foundation Clip ...........................................39Glass Block Panel Anchors .........................27Heavy Duty Seismic Ladur-Eye ...................30Ins-O-Grips ..................................................18Joint Stabilizing Anchor ...............................21Ladur ...........................................................26Ladur Double Side Rod ...............................26 Ladur Joint Reinforcement ..........................27Ladur Trirod .................................................27Ladur-Eye ....................................................29Lite Duty Seismic Channel Anchor ...............9Lite Duty Seismic Dovetail Triangular Ties ..16Lite Duty Seismic Dur-O-Eye.......................31Lite Duty Seismic Ladur-Eye .......................31Lite Duty Seismic Pintles .............................15Lite Duty Seismic Triangular Tie .................15Masonry Expansion Anchor ........................ 11Mechanical Anchor Series ...........................40Metal Stud Veneer Screw ............................ 11Mor-Control..................................................24Mortar Net™ ................................................24Mortar-Stop™ ..............................................24Mounting Plate ............................................38MSSA Veneer Anchor Screw-On Straps......10Nut .................................................................7OCM Masonry Anchor ...................................7Pencil Rod Deformed (Straight and Cut) ...16,32Plastic Horseshoe Washers ..........................7Poly-Barrier Thru-Wall Flashing...................23PowerBOX Recessed Door Header ..............4PowerBOX Steel Lintel ..................................4PowerSPAN Brick Veneer Lintel ....................5PowerSPAN Cantilever Corner Lintel ............5PowerSPAN Elliptical Steel Lintel ..................5PowerSPAN Flat Radius Lintel ......................4PowerSPAN I-Beam ......................................5PowerSPAN L-2 Lintel ...................................4

Product .................................................. PagePowerSPAN True Arch Lintel .........................4PVC Sheeting ..............................................22Rapid “T” PVC Control Joint ........................21Rapid “T” Rubber Control Joint....................20Rapid Expansion Joint .................................21Rapid Soft Joint ...........................................21Rebar Positioners ........................................17Rebar Positioners ........................................17Rectangular Cavity Wall Ties .......................12Regular PVC Control Joint ..........................20Regular Rubber Control Joint ......................20Seismic Veneer Anchor Pintles...................14Seismic Veneer Anchor Plates ...................14Seismic Channel Anchor ............................15Seismic Combs............................................15Seismic Dovetail Anchors ............................14Seismic Dur-O-Eye ......................................30Seismic Ladur (Masonry Reinforcement for Veneers).........16Seismic Ladur Joint Reinforcement .............33Seismic Veneer Anchor ...............................14Shelf Angle Insert ..........................................7Stainless Steel Screw .................................. 11Stone Anchors .........................................8, 19Strongback Ties ...........................................38Strongbacks and Struts ...............................39Termination Bar ...........................................23Trapezoid Ties (or Web Ties).......................13Triangular Tie Series ...................................12Triangular Ties with Restraint Bar ...............34Truss ............................................................26Truss Double Side Rod ...............................27Truss Trirod .................................................27Veneer Anchor Screw-On Plates .................10Veneer Anchors (Plates and Pintles) ...........10Wall Ties .....................................................38Wall Top Stabilizing Anchor .........................21Wedges .......................................................38Weep Holes or Tubes ..................................23Window Sill ....................................................5Wire Mesh Ties ............................................13Wood Stud Veneer Screw ........................... 11“Z” Cavity Wall Ties ..................................... 11

Detailed Index

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL has been manufacturing and supplying quality products to the masonry construction

industry since 1939. As an innovator in designing new and improved products for masonry

construction, we have been responsible for state-of-the-art systems for moisture control, seismic

applications, masonry connection and masonry repair. Years of experience in engineering, manufacturing

and serving the masonry industry have provided us with a thorough understanding of the needs of masonry

construction professionals everywhere. DUR-O-WAL maintains ongoing product-testing and quality control to

insure that every product meets the highest industry standards. Our knowledge of the engineering of masonry

structural performance gives you the confidence to say...

DUR-O-WAL can truly “Do It All”.

© Copyright 2008 - Dayton Superior Corporation

Index

Item PageBR20 ............................................................37BR23 ............................................................37BR39 ............................................................37DA100 ............................................................8DA101.......................................................8, 19DA102...........................................................19DA103...........................................................19DA131...........................................................14DA200 ............................................................8DA201 ..........................................................19DA203...........................................................19DA204...........................................................19DA205...........................................................19DA207 ..........................................................10DA210...........................................................10DA210X ........................................................10DA213.....................................................10, 14DA213 S ......................................................14DA213QT .....................................................15DA301...........................................................19DA301U ........................................................19DA301Z ........................................................19DA303...........................................................19DA304...........................................................19DA305...........................................................19DA306...........................................................19DA307...........................................................19DA308...........................................................19DA309...........................................................19DA331...........................................................19DA332...........................................................19DA333...........................................................19DA334...........................................................19DA335...........................................................19DA336...........................................................19DA337...........................................................19DA338...........................................................19DA339...........................................................19DA411 ..........................................................21DA431 ..........................................................14DA500........................................................... 11DA508 ..........................................................40DA510...........................................................12DA511 ...........................................................12DA518...........................................................12DA519 ..........................................................15DA601...........................................................12DA604.............................................................2DA700...........................................................12DA700QT .....................................................15DA700WB ....................................................34DA709...........................................................13DA720 ............................................................8DA720. ...........................................................8DA720QT ......................................................16DA730...........................................................13DA750...........................................................13DA800BC .....................................................38

Item PageDA800BP ......................................................38DA800CA .....................................................39DA800FB .....................................................38DA800FC .....................................................39DA800MP ....................................................38DA800S .......................................................39DA800SBP ...................................................38DA800ST .....................................................38DA800W ......................................................38DA800WT ....................................................38DA801...........................................................10DA807........................................................... 11DA808........................................................... 11DA810 ..........................................................17DA811 ..........................................................17DA812 ..........................................................17DA813 ..........................................................15DA815 ..........................................................17DA816 ..........................................................17DA817 ..........................................................17DA901 ............................................................8DA902 ............................................................9DA903 ............................................................9DA904 ............................................................9DA911 ...........................................................19DA913...........................................................19DA914...........................................................19DA917...........................................................19DA918.............................................................9DA918QT .....................................................16DA931.......................................................9, 15DA960...........................................................13DA980...........................................................13DA990...........................................................13DA995...........................................................34DA1001 ..........................................................7DA1002 ..........................................................7DA1003 ..........................................................7DA1004 ..........................................................7DA1005 ........................................................23DA1006 ........................................................23DA1007.........................................................24DA1008.........................................................24DA1009 ........................................................24DA1010 ........................................................18 DA1015.........................................................18DA1018 ........................................................18DA1020 ........................................................18DA1070 ........................................................27DA1501 ........................................................22DA1502 ........................................................22DA1505 ........................................................22DA1506 ........................................................22DA1507 ........................................................22DA1508 ........................................................22DA1510 ........................................................23DA1525 ........................................................23DA1540 ........................................................23

Item PageDA1544 ........................................................23DA2001 ........................................................20DA2002 ........................................................20DA2003 ........................................................20DA2004 ........................................................20DA2006 ........................................................21DA2007 ........................................................21DA2010 ........................................................21DA2015 ........................................................21DA2016 ........................................................25DA2020 ........................................................21DA2025 ........................................................20DA2100 ........................................................18DA2200 ........................................................21DA3000SL .................................................. 11DA3100.........................................................26DA3100DSR ...............................................27DA3100TR ...................................................27DA3200.........................................................26DA3200 ........................................................27DA3200DSR ................................................27DA3200S .....................................................33DA3200TR ..................................................27DA3200S .....................................................16DA3300SL ...................................................34DA3400 ........................................................28DA3500 ........................................................28DA3600 ........................................................29DA3600ES ...................................................31DA3600S .....................................................30DA3700 ........................................................29DA3700ES ...................................................31DA3700S .....................................................30DA5000 ........................................................40DA5100 ........................................................40DA5213.........................................................40DA5213S ......................................................40DA5300 ........................................................40DA5410.........................................................40DA5431.........................................................40DA5610 ........................................................ 11DA5801 ........................................................40DA8200 ..........................................................6DA8210 ..........................................................6DA8220 ..........................................................6DA8230 ..........................................................6DA8706 ........................................................16DA8706 ........................................................32DA8801 ..........................................................7DA9000 ..........................................................4DA9100 ..........................................................4DA9150 ..........................................................5DA9200 ..........................................................4DA9300 ..........................................................4DA9400 ..........................................................4DA9500 ..........................................................5DA9600 ..........................................................5DA9800 ..........................................................5DA9900 ..........................................................5

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Design Information

BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-05/ASCE 5-05/TMS 402-05) and SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-05/ASCE 6-05/TMS 602-05)

The above Code and Specifications states the following: Joint reinforcement, wall ties and anchors shall be stainless steel or protected from corrosion by a hot-dipped galvanized coating or epoxy when used in masonry that is exposed to organic mat-ter or weather and interior walls exposed to a mean relative humidity exceeding 75%. All other joint reinforcement, wall ties, anchors and inserts shall be mill galvanized, hot dipped galvanized or stainless steel. Anchor Bolts, steel plates and bars not exposed to earth, weather nor exposed to a mean relative humidity exceeding 75%, need not be coated.

CORROSION PROTECTIONCorrosion (rusting) of masonry joint reinforcement, ties and anchors will ultimately lead to product failure with resulting dam-age to the masonry structure. To assist the user in selecting the proper corrosion protection, Dur-O-Wal offers the following comments:

• Productsmanufacturedfromstainlesssteelofferthegreatestlevelofcorrosionresistance.Dur-O-Walrecommendsstainless steel products for use in light-colored masonry construction and where maximum corrosion resistance for joint reinforcement, ties and anchors is required.

• HotDipGalvanized(HDG)providesathickzinccoatingthatisappliedafterfabricationtoassurethatweldsandexposed(cut) edges are coated. Usually specified when joint reinforcement, ties and/or anchors are to be embedded in masonry exposed to earth, weather conditions and/or areas of high humidity.

• MillGalvanizedprovidesathinzinccoatingthatisappliedtothesteelbeforeproductfabrication.Millgalvanizingprovidesabalancebetweeneconomyandcorrosionresistance.Weldsandexposededgesarenotprotectedwithzinc.Millgalva-nized products are normally specified for joint reinforcement, ties and/or anchors used in interior masonry construction thatisnotexposedtohighrelativehumidityconditions,butneverinGlassBlockMasonry.

• Dur-O-Waldoesnotrecommendtheuseofjointreinforcement,tiesandanchorsmanufacturedfrombritebasicwireorplain (uncoated) carbon steel sheet metal as such products are not protected from corrosion and will corrode while stored inawarehouse,intransitorinstorageatajobsite.Considertheuseofplainsteelonlywhenfieldweldingwouldmakegalvanized ties and anchors impractical or when parts are to be galvanized after fabrication.

• Mostbuildingcodesdonotrequirestructuralcomponentssuchasanchorbolts,steelplatesorbarsexposedtoearth,weather conditions or high humidity to have corrosion protection.

• EpoxycoatingisnotrecommendedbyDur-O-Walforcorrosionprotectiondueto“holidays”thatdevelopduringthecoat-ing process and the potential for subsequent corrosion that may result from them.

• Forextendedlifeandcorrosionprotection,restorationanchorsarefabricatedwithbrasssleeves,brassextensioncones,stainlesssteelinnerrodsandstainlesssteelorHDGboltsandwashers.

• Pleaseseeindividualproductdescriptionsforspecificmaterialandfinishinformation.

DUR-O-WAL MATERIAL, PRODUCT AND COROSSION PROTECTION SPECIFICATIONS

MATERIAL ASTM STANDARD SPECIFICATIONSBrass ASTM B-16/B16M-05Bolts and Anchor Bolts A307-07bMasonry Joint Reinforcement A951/A951M-06PVC Control Joints D2207-00 (2005)Reinforcing Steel A615/A615M-07Rubber Control Joints D2000-08Sheet Metal, Carbon Steel A1008/A1008M-07a, A109/A109M-03 and A1011/A1011M-07Sheet Metal, Hot Dipped Galvanized A153/A153M-05 (1.50 oz/ft2 - 458 g/m2)Sheet Metal, Mill Galvanized A653/A653M-07 (0.60 oz/ft2 - 183 g/m2)Sheet Metal, Stainless Steel A167-99 (2004) - Type 304Steel Plate, Carbon Steel A36/A36M-05Wire, Carbon Steel A82/A82M-07Wire, Hot Dipped Galvanized A153/A153M-05 (1.50 oz/ft2 - 458 g/m2)Wire, Mill Galvanized A641/A641M-03 (0.10 oz/ft2 - 30 g/m2)Wire, Stainless Steel A580/A580M-06

2

NOTE: Thinbrickorstoneweighing15psforlessdoesnotneedtobemechanicallyattachedtostructuralbacking. Thismaterialisadhereddirectlytothebacking.

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

POWERBOX AND POWERSPAN STEEL LINTELSThe steel lintels offered by Dur-O-Wal are a distinctly different type of lintel, designed especially for masonry construction. These steel lintels offers a real alternative, in both residential and commercial masonry structures, to the traditional angle iron, cast stone, cast-in-place or precast concrete lintels. Dur-O-Wal steel lintels will span openingsasnarrowas1’-4”andaswideas40’-0”.

Due to their lightweight, PowerBOX and PowerSPAN steel lintels are easy to lift and set into position. One or twoworkerscaneasilyinstalltheselintelswithoutef-fort or injury. Not only do these lintels offer the mason contractorsavingsinlaborcosts,duetolessworkersrequired for installation, they also offer the additional advantageofreducingworkerscompensationinsuranceclaims, when compared to using heavy cast stoneor precast concrete lintels. In addition, these lintels do notrequirecostly“specialinspection”duringinstallation.Professionally engineered and factory fabricated, allow-ingthearchitectorengineertoquicklyandeasilydesignlarge open affordably spaces using masonry construc-tion.

LOAD TABLESLoad tables are available on request, listing clear span, lintel length, allowable grav-ity, up-lift and out-of-plane super-imposed loads. Load tables specify any rebar that may be required as well as theheightofCMUthatis required to be solidly grout-ed for composite action with the lintel.

FEATURES• Easytoinstall.• Onlyonepersonneeded to set.• Lengthsizedtofitproject opening.• Meetsorexceedsmost load bearing requirements andcodesinall50states.• Eliminatescolumns.• Canreduceinsurance costs.

Forcompleteinformation,please request a copy of our Dur-O-Wal Steel Lintel brochure (DOW10).

Steel Lintels

3

27’-4”ClearSpan-NoColumns!

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Steel Lintels

LINTEL TYPESDuetotheirlightweight,PowerBOXandPowerSPANsteellintelsareeasytoliftandsetintoposition.Oneortwoworkerscaneasily install these lintels without effort or injury. Not only do these lintels offer the mason contractor savings in labor costs, due tolessworkersrequiredforinstallation,theyalsooffertheadditionaladvantageofreducingworkerscompensationinsuranceclaims, when compared to using heavy cast stone, cast-in-place or precast concrete lintels. In addition, these lintels do not re-quirecostly“specialinspection”duringinstallation.

The Dur-O-Wal Steel Lintel are offered in the following types and sizes:

DA9000 PowerBOX Steel LintelU.S.Patent#6367209

• EliminatesfirstcourseofCMUaboveopening.• Nominal8”x8”.• Actualsizeis7-5/8”widex7-5/8”tall.• Clearspansfrom3’-2”to40’-0”.• 8”lintelendbearingonsupportingCMU,depending on lintel length.• 18or16gaugethicknessdependingonlintellength. • 18gaugeweighs4.3plfand16gaugeweighs5.4plf.• 4hourfireratingwhengroutedsolid.• Large4-1/2”groutopeningateachend.

DA9100 PowerBOX Recessed Door HeaderPatent#6367209

• EliminatesfirstcourseofCMUabovedoor.• Nominal8”x6”.• Actualsizeis7-5/8”widex5-5/8”tall.• Headerclearspansfrom1’-6”to18’-8”.• 8”headerendbearingonsupportingCMU, depending on header length.• 16gaugethickness.• 4hourfireratingwhengroutedsolid.• Large4-1/2”groutopeningateachend.

DA9200 PowerSPAN L-2 LintelU.S.Patent#5465538

• Halftheweightoftraditionalangleironlintels,yetjust as strong.• 6-3/4”wideforusewith8”nominalCMU.• Two2-1/2”tallcenterribsforaddedstrength.• Lintelslengthsfrom1’-6”to36’-0”.• 4”endbearingonsupportingCMU.• 16gaugethickness.• Weighs3.3plf.• Canbecuttolengthatjobsite.

DA9300 PowerSPAN TRUE ARCH LINTELPatent#5465538

• Usewherefullyarchedopeningsarerequired.• 6-3/4”wideforusewith8”nominalCMU.• 2-1/2”tallcenterribforaddedstrength.• 4”endbearingonsupportingCMU.• 12gaugethickness.• Speedsconstructiontime.• Availableinawidevarietyofradiuses,customsized to project specifications.• Nowoodformingnecessarytoobtainatrueradius.

4

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA9400 PowerSPAN Flat Radius LintelU.S.Patent#5465538

• Usetoconstructaccuratecurvedmasonrycorneror window walls.• 6-3/4”wideforusewith8”nominalCMU.• 2-1/2”tallcenterribforaddedstrength.• 4”endbearingonsupportingCMU.• 12gaugethickness.• Allowsflatradiuslintelstobeaccuratelyfabricated to required radius.

DA9500 PowerSPAN Cantilever Corner LintelU.S.Patent#5465538

• Designedtocreatedramaticandunobstructedcorner views.• 6-3/4”wideforusewith8”nominalCMU.• Two21/2”tallcenterribsforaddedstrength.• 4”endbearingonsupportingCMU.• 16gaugethickness.• 5’-4”standardleglengthsforupto4’-0”cantilevers.

DA9600 PowerSPAN Brick Veneer LintelU.S.Patent#5465538

• Allowsmasonstoaccuratelylaybrickworkabove openings. • 12gaugebrickveneerplate. • Usewith8”nominalCMU. • Providesfor2”airspacebetweenbrickveneerandCMU. • Requiresveneertiesoranchorstobespacedat16” centers horizontally and vertically.

DA9800 PowerSPAN Elliptical Steel LintelU.S.Patent#5465538

• Usetoaccuratelyconstructellipticalmasonryarches.• 6-3/4”wideforusewith8”nominalCMU.• 2-1/2”tallcenterribforaddedstrength.• 4”endbearingonsupportingCMU.• 12gagethickness.

DA9900 PowerSPAN I-Beam• Usewhenthereislimitedmasonryaboveopeningwith point loads on lintel.• Availableinawidevarietyoflengthsandsizesas specified.• Thelintelheightandtherebarsizeattopoflintel,canvary as required to meet project requirements.

DA9150 Window Sill• Dripedgeforextraprotectionfromwaterpenetration. • Availableinstandardlengthsfrom193/4”to10’-0”.• Customsizingavailable.

Steel Lintels

5

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Dur-O-Splice Masonry Rebar Splicing System

6

DA8200 Dur-O-Splice The use of lap splices in vertically reinforced masonry walls can be time consuming in terms of design and installation and can lead to congestion within the cell of a concrete masonry unit, decreasing the chance of completely filling the cells with grout.

As lapped splices are dependent on the grout for load transfer, incomplete grout consolidation will significantly affect the perfor-mance of a lapped rebar splice as well as the strength of the masonry wall.

Dur-O-Wal has developed the Dur-O-Splice Rebar Splicing System, to eliminate the lap splicing of rebars. Lap splices may pull apart due to seismic forces.

TheDur-O-Splicesystemhasbeendesignedwithataperedthreadthatallowsthesystemtodevelop125%oftheGrade60rebar’syieldstrength,whensnugtightened.Atorquewrenchisnotnormallyrequiredtotightenthecouplerontothetaperedthreaded rebar.

The Dur-O-Splice System greatly simplifies vertical rebar placement, eliminating rebar congestion and increases the chance of getting complete grout consolidation throughout the wall

The Dur-O-Splice will develop its strength even when the grout has not been completely consolidation and will retain its strength despite grout degradation from impact damage or seismic forces.

FEATURES• Designfriendly.• Nospecialtoolsorskillsrequired.• Conformstomasonrybuildingcodes.• Eliminateslapsplicingofrebars.• Simplifiesrebarinstallation.• Reducesrebarcongestion.• Fastandcosteffective.• Increaseschanceof100%groutfilledcells.• Selfaligningtaperedthreadsforeaseofinstallation.• Taperedthreadspreventscross-threading.• Reducesthetotalamountofrebarduetotheeliminationoflapsplices.

The Dur-O-Splice System consists of four parts:• DA8200TaperedThreadedRebar• DA8210EndAnchor• DA8220ThreadProtector • DA8230StandardCoupler

Sizes vary with size of rebar specified.

DA8200 TAPERED THREADED REBARAvailablein#4,#5and#6rebarsizesandinstandardlengthsof48”or64”withotherlengthsavailableonspecialorder.Thethreadedendsareprotected by plastic thread protectors.

DA8210 DUR-O-SPLICE END ANCHOR Anover-sizedendanchorthatisthreadedontotheendofaDA8200ta-pered threaded rebar. The end anchor creates anchorage the necessary resistancetopull-outfromtheconcretefooter.Thisisanalternativetoa90°hookedrebaroranchorbolt.

DA8220 DUR-O-SPLICE THREAD PROTECTORAplasticbreak-awaythreadprotectorisplacedovertheendofaninstalledtapered threaded rebar to protect the threads from mortar dropping.

DA8230 DUR-O-SPLICE COUPLER A round carbon steel rebar coupler that has tapered threads at both ends. CoupleriseasilysnugtighenedontotheDA8200TaperedThreadedRebar.

ICC Evaluation Services approval report: ESR-2481

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Shelf Angle and OCM Masonry Rebar Anchor

DA8801 OCM Masonry AnchorFunction: A mechanical rebar anchoring system consisting of a mechanical expansion anchor preassembled to a lengthofGrade60rebar.Installswithjustasledge hammer“blow”. Can be used as a foundation dowel or to tie vertical reinforcing steel in masonry wall construction to a poured-in-placeconcretefoundationorfloorslab.

•Quickandeasyrebarinstallation.

•Placerebarexactlywhereneeded.

•Noinstallationdelaysduetobadweather.

•Nochemicalsrequiredduringinstallation.

•Nocuringtimerequired.

•Providesexcellentlaborsavings.

Dimensions: Available in the following standard sizes and lengths: •ExpansionAnchorwith#4x24”longrebar. •ExpansionAnchorwith#5x30”longrebar. •ExpansionAnchorwith#6x36”longrebar. Above lengths do not include the expansion anchor portion of the assembly. Other lengths are available on special order.Finish: The expansion anchor (Expander Sleeve and Expander Cone) is electro-zinc plated with a colorless chromate coating for corrosion protection. Reinforcing steel is supplied as hot-rolled from the mill without any type of protective coating.

DA1001 Shelf Angle InsertThis insert is used in cast-in-place concrete construction as an anchor to attachbrickshelfanglestothefaceofconcrete.Itisavailableforusewith3/4”AskewHeadBolts,andnuts.

Ultimatetensioncapacityis7,500lbs.in4,000psinormalweightconcrete.Todevelopthiscapacity,theinsertmustbeinstalledaminimumof1-1/2”above the bottom edge of the concrete.

Nail holes are provided to allow for nailing of the insert to the concrete formwork.

DA1002 Askew Bolt and DA1003 NutAskewheadboltsaremadewiththeheadataslopetomatchthe wedge-shapedtracksoftheshelfangleinsert.Theboltsmustbeplacedintothe insert properly so the head of the bolt has full bearing on the insert. Care mustbetakentoinsurethattheboltisnotinstalledupsidedown.

Askewheadboltsareavailablein3/4”diameterx1-1/2”,2”,2-1/2”and3”lengths.Ultimateshearcapacityis9,060lbs.

Alwaystightenthehexnuttoa“snugtight”conditiononly.“Snugtight”isdefined as the tightness attained to ensure that the parts of the material are infullcontactwitheachother,plus1/2turnwitha12”longwrench.Carelesswrench tightening or turn-of-nut tightening can induce tension loads into the insert that are in excess of the design capacity and should be avoided.

DA1004 Plastic Horseshoe WashersAvailablein1/16”,1/8”or1/4”thicknessx2”x2”with13/16”x2-7/16”or1/16”,1/8”or1/4”thicknessx3”x4”with13/16”x2-15/16”slot.

Rebar

Expander Cone

Expander Sleeve

7

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Dovetail & Channel Anchor Systems

DA100 DOVETAIL ANCHOR SLOTSFunction: Designed to anchor masonry to new concrete with the slot embeddedinconcrete.UsedwithallDA100SeriesDovetail AnchorsandDA720.DovetailTriangularTiesAnchors,and DA200SeriesStoneAnchors. ForSeismicDovetailAnchorsseeSeismicSection.Dimensions: 26gage(48mm),24gage(0.61mm),22gage(0.76mm)or 20gage(0.89mm)x10feet(3050mm)length. 1inchx1inchx5/8inchthroat(25mmx25mmx16mm)Finishes: MillGalvanizedandStainlessSteel.Special Notes: Slot is foam filled to protect slot during concrete forming and placement.

DA101 DOVETAIL ANCHORSFunction: Designed to anchor masonry to concrete. UsedwithDA100DovetailAnchorSlot.Dimensions: 16gage(l.5mm),14gage(1.9mm),12gage(2.7mm)x 1inch(25mm)widex3-1/2inch(90mm),4-1/2inch (113mm),5-1/2inch(138mm),6-1/2inch(163mm)lengths (length does not include dovetail). Dovetail measures 1inch(25mm)inlength.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Otherlengthsandthicknessavailable. • Other styles available with twists, bends, holes, splits, etc. • SeeSeismicSectionforpopularDA131DovetailAnchor which has been fully tested and can be substituted for DA101.

DA720 SERIES DOVETAIL TRIANGULAR TIESFunction: Designed to anchor masonry to concrete. UsedwithDA100DovetailAnchorSlot.Dimensions: 12gage(2.7mm)DovetailClipwith3/16inch(5mm) wiretiex3-1/2inch(90mm),4-1/2inch(113mm), 5-1/2inch(138mm),6-1/2inch(163mm),7-1/2inch(193mm) and9-1/2inch(243mm)lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Can adapt for Seismic Zones see Seismic Section.

DA901 CHANNEL ANCHOR SLOTFunction: Designedtoanchormasonrytoconcrete,CMU,brickorsteel columns. UsedwithDA900SeriesChannelAnchors.Dimensions: 16gage(l.5mm)or11gage(3mm)x8inch(200mm)length x1-3/4inch(43mm)wide. Slotmeasures9/16inchwidex5-1/2inches (14mmx151mm)longFinishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Slothastwo5/16inch(8mm)holesaboveandbelowslot. • Power-drivenfastenersintoconcrete,blockorbricknot recommended. • Not recommended against sheathing over wood or metal stud.

8

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Dovetail & Channel Anchor Systems

DA902 CHANNEL ANCHOR SLOTFunction: Designedforembedmentinblockmasonryforanchoring veneertoCMUbacking.UsedwithDA900SeriesChannel Anchors.Dimensions: SameasDA901excepthastwowelded3inch(75mm)long legs perpendicular to slot and each leg has a right angle bend.

Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.

DA903 CHANNEL ANCHOR SLOTFunction: Designed for anchoring masonry to a structure including over sheathing for wood and metal stud applications. Used with DA900SeriesChannelAnchors.Dimensions: SameasDA901exceptis11inch(275mm)length.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Fabricatedtoenableslottobeplacedforattachmentflush againstbacking

DA904 CONTINUOUS CHANNEL ANCHOR SLOTFunction: Designedtoanchormasonrytoconcrete,block,brickor steelcolumns.UsedwithDA900SeriesChannelAnchors.Dimensions: 16gage(1.5mm)or11gage(3mm)x8feet(2440mm)length x1-3/4inch(43mm)wide.12usableslotsmeasure9/16inchx5-3/8 inches(14mmx135mm).Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: •Not recommended against sheathing over wood or metal stud. •Fenderwasherofappropriatesizerequiredwhenslotsare usedtoaccommodatedrill-infastenerstoconcrete,blockor brick. •Power-driven fasteners not recommended.

DA918 SERIES CHANNEL ANCHOR TRIANGULAR TIESFunction: Designedtoanchormasonrytoastructure.UsedwithDA901, DA902,DA903,orDA904ChannelAnchorSlots.Dimensions: 12gage(2.7mm)ChannelAnchorClipwith3/16inch(5mm) wiretiex3-1/2inch(90mm),4-1/2inch(113mm),5-1/2inch (138mm),6-1/2inch(163mm),7-1/2inch(193mm)and 9-1/2inch(243mm)lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Can adapt for Seismic Zones see Seismic Section.

DA931 CHANNEL ANCHORSFunction: Designedtoanchormasonrytoastructure.UsedwithDA901, DA902,DA903,orDA904ChannelAnchorSlots.Dimensions: 16gage(l.5mm),14gage(1.9mm),or12gage(2.7mm)x 1inch(25mm)widex3-1/2inch(90mm),4-1/2inch(113mm),or 5-1/2inch(138mm)lengths(lengthdoesnotincludeChannel Anchor“T”)Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: •Otherlengthsandthicknessavailable. •OlderstylesofDA900SeriesAnchors,generallyreplacedwith DA931,arestillavailable. •MeetsrequirementsforSeismicZonesseeSeismicSectionfor details.

9

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Ties, Anchors & Veneer Anchors

DA207 MSSA VENEER ANCHOR SCREW ON STRAPSFunction: Designed to anchor masonry to a structure. UsedwithDA700TriangularTiesorDA750TrapezoidTies.Dimensions: 3/4inch(19mm)widex5inches(125mm)longx12gage(2.7mm)thickFinishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: •Has1/4inch(6mm)clearance. •Requirestwofasteners. •Notrecommendedformetalorwoodstudoversheathing (SuggestDA210AnchorPlateorDA213VeneerPlate). •Notrecommendedwhencavitycontainsrigidinsulation (SuggestDA213orDA210XVeneerAnchors). •CanadapttoSeismicZonesseeSeismicSection.

DA210 VENEER ANCHOR SCREW ON PLATESFunction: Designed to anchor masonry to a structure. Used with DA700 Triangular Ties or DA750 Trapezoid Ties.Dimensions: 1-1/2 inches (37mm) wide Back Plate 6 inches (150mm) long 14 (1.9mm) or 12 (2.7mm) gage thickFinishes: Mill Galvanized; Hot Dip Galvanized; or Stainless Steel.Special Notes: •Has 1/4 inch (6mm) clearance. •Requires two fasteners. •Not recommended when cavity contains rigid insulation (Suggest DA213 or DA210X Veneer Anchor). •Can adapt to Seismic Zones see Seismic Section.

DA210X VENEER ANCHOR SCREW ON PLATESFunction: Designed to connect masonry veneer to metal stud framed structural backings. Used with DA700 Series Triangular Ties.Dimensions: Availablein14gaugeandmeasures11/4”widex5”long,legssized toaccommodate5/8”,3/4”,1”,11/2”,2”,21/2”and3”insulationor sheathing. Finishes: Millgalvanizedandhotdipgalvanized.Special Notes: •Requirestwofasteners. •Can be used with or without rigid foam insulation. •Provides 3-3/4” of vertical tie adjustment to meet variations in the masonry coursing.

DA213 VENEER ANCHORS (PLATES AND PINTLES)Function: Designed to anchor masonry to a structure accommodating rigid insulation up to and including 3 inches (75mm).Plate Dimensions: 14(1.9mm)or12(2.7mm)gagewithlegtoaccommodaterigidinsulation.Pintle Dimensions: 3/16inch(5mm)wirex3inches(75mm),4inches(100mm), 5inches(125mm),6inches(150mm),or7inches(180mm)long.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Recommendtwofastenersperplate. • Needs3/4inch(19mm)to1inch(25mm)minimumaircavity. • CanadaptWirePintletoSeismicZonesseeSeismicSection. • Forattachmenttoconcrete,brickorblockuseDA5213. • Fullytested.

DA801 ADJUSTABLE SPEED SET VENEER ANCHORSFunction: Designed to anchor masonry to a structure.Plate Dimensions:14(1.9mm)gagethick1/2inch(25mm)depth3inch(75mm)longTri Tie Dimension:3/16inch(5mm)wirex3inch(75mm),4inch(100mm),or5inch (125mm)lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Usesonefastener. • AnchorcomesassembledwithTriangularTieinPlate. • Forattachmenttoconcrete,brickorblockuseDA5801.

10

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Ties, Anchors and Veneer Anchors

DA807 METAL STUD VENEER SCREWFunction: Designedtofastenanchorstometalstudbacking.Dimensions: #10-16x1-1/2(38mm)longor#12-14x2”(50mm)long.Finishes: Copolymer coated for corrosion resistance.Special Notes: Available with or without Neoprene Washer.

DA808 WOOD STUD VENEER SCREWFunction: Designedtofastenanchorstowoodstudbacking.Dimensions: #9PhillipsHead,1-5/8inches(41mm)or 2-1/4inches(57mm)long.Finishes: Proprietary corrosion resistant coating.

DA995 STAINLESS STEEL SCREWFunction: Designedtofastenanchorstometalstudbacking.Dimensions: #12-14x1-1/2inches(38mm)or2inches(50mm)long.Finishes: Type304StainlessSteelwithCaseHardened Carbon Steel Drill Point.Special Notes: Screw is self-drilling and self-tapping with NeopreneWasheravailablefor2inch(50mm)longscrew.

DA5410 AND DA5610 MASONRY EXPANSION ANCHORSFunction: Designedtofastenanchorstoconcrete,CMU,brick,tile,and into mortar joints.Dimensions: 7/16inch(11mm)outsidediameterx2inches(50mm)long.Finishes: 1/4-20NCHexheadboltandwasherofHDGCarbonSteel DA5610)orType304stainlesssteel(DA5410;Expansion Sleeve and Expander Cone of brass.Special Notes: SoldassetswithanchorsasinDA5213;DA5213S;DA5431; DA5801andindividually.

DA301Z MASONRY STRAP ANCHORFunction: Variousmasonryapplications.

Dimensions: Coderequired1/4inch(6mm)thick1-1/2inch(38mm)wide 24inch(600mm)longwith2inch(50mm)long,90degree bends on each end.Finishes: HotDipGalvanized;orStainlessSteel.Special Notes: Other dimensions and shapes available.

DA500 “Z” CAVITY WALL TIESFunction: Designed to tie multiwythe masonry walls when fully grouted.Dimensions: 3/16inch(5mm)wirewith2inch(50mm)bendswithvarious lengths between bends.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Provides no adjustability between wythes. ForcavitydripuseDA2100Ins-O-Grips.

11

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

12

Ties, Anchors and Veneer Anchors

DA510 AND DA511 RECTANGULAR CAVITY WALL TIESFunction: Designed to tie multiwythe masonry walls.Dimensions: DA5103/16inch(5mm)wirex2inch(50mm)widewithvarious lengths. DA5113/16inch(5mm)wirex4inch(100mm)widewith various lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Provides no adjustability between wythes. • ForcavitydripuseDA2100Ins-O-Grips.

DA518 ADJUSTABLE RECTANGULAR CAVITY WALL TIE EYES(FormerlyknownasDA515)Function: Designed to tie multiwythe walls with adjustability between thewythes.UsedwithDA213WirePintle.Dimensions: 3/16inch(5mm)wirex2-3/4inch(70mm),4-3/4inch (119mm),or5-3/4inch(144mm)lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Allowsforonly1/16inch(2mm)playwhenlegofpintleis engaged in eye. • Can adapt Wire Pintle to Seismic Zones, see Seismic Section.

DA601 COLUMN ANCHORSFunction: Designedtoanchorblocktosteelcolumnflanges.Dimensions: 1/8inch(3mm)thickx2inch(50mm)widewith1inch(25mm) right angle bend with various lengths.Finishes: HotDipGalvanized;orStainlessSteel.Special Notes: • Requires two anchors, one for left and right hand side of flange. • Fullytested.

DA604 COLUMN ANCHORSFunction: Designedtoanchorbricktosteelcolumnflanges.Dimensions: 16(1.5mm)gagethickx1inch(25mm)widecorrugatedwith various lengths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: • Requires two anchors one for each left and right hand side of flange. • Fullytested.

DA700 SERIES TRIANGULAR TIESFunction: Designed to anchor masonry to a structure. UsedwithDA207MSSAVeneerAnchorScrewonStrap, DA210VeneerAnchorScrewonPlateorDA709ColumnAnchor Weld-on.Dimensions: 3/16inch(5mm)wire,3x3inches(75mmx75mm), 4x4inches(100mmx100mm),5x5inches(125mmx125mm), 6x6inches(150mmx150mm),7x7inches(180mmx180mm), and7x9inches(180mmx230mm).Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Can adapt for Seismic Zones, see Seismic Section.

18 D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Ties, Anchors and Veneer Anchors

WIDTH

WIDTH

F/RP

F/P

DA709 COLUMN ANCHOR WELD-ONFunction: Designed to anchor masonry to structural steel columns. UsedwithDA700SeriesTriangularTiesorDA730TrapezoidTies.Dimensions: 5/16inch(8mm)rodx5inch(125mm)length.Finishes: BriteorPlainUncoated;MillGalvanized;orHotDipGalvanized.

DA730 TRAPEZOID TIES (OR WEB TIES)Function: Designed to anchor masonry to a steel structure from the endoftheCMUusingawireanchorsuchasaDA709.Dimensions: 3/16inch(5mm)wirex12inch(300mm)overalllength, 1”bendswithvariouswidths.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Order by actual width of masonry unit being used.

DA750 TRAPEZOID TIES (OR WEB TIES)Function: Designed to anchor masonry to a structure from the end oftheCMUusingastrapanchorsuchasaDA207orPlate AnchorsuchasDA210.Dimensions: 3/16inch(5mm)wirex12inch(300mm)overalllength, 1”bendswithvariouswidthsFinishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Order by actual width of masonry unit being used.

DA960 WIRE MESH TIESFunction: Varietyofapplications.Dimensions: 1/2inchx1/2inch(13mmx13mm)meshof16gage(1.5mm) wire in 3 inch (75mm) widths and various lengths.Finishes: HotDipGalvanized.Special Notes: • Availableinrollsof100feet(30.48M)lengthineither 36inch(915mm)or48(1220mm)inchwidths. • Other widths of Ties and Rolls available.

DA980 COLUMN FLANGE TIESFunction: F/PStyle:Designedtoanchormasonrytoasteelcolumnflange paralleltotheflange. F/RPStyle:Designedtoanchormasonrytoasteelcolumn flangeatarightangletotheflange.Dimensions: 3/16inch(5mm)wirewitha21/2inch(64mm)hookwitha 1/2inch(13mm)openinginvariouslengthsanda2inch (50mm)rightanglebend.Finishes: MillGalvanized;HotDipGalvanized;orStainlessSteel.Special Notes: Requires two anchors, one for left and right hand side of flange.

DA990 CORRUGATED WALL TIESFunction: Designed to anchor masonry to a structure or to tie multi wythe walls. Use in residential construction only.Dimensions: 26gage(0.45mm),22gage(0.76mm)or16gage(l.50mm)x 7/8inch(22mm)widex7inch(180mm)length.Finishes: MillGalvanized;HotDipGalvanizedavailablein26,22and16 gages;andStainlessSteelavailablein22and16gages.Special Notes: Other lengths and widths are available

13

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA131 SEISMIC DOVETAIL ANCHORSFunction: Designed to anchor masonry to concrete with joint reinforcementintheveneer.UsedwithDA100DovetailAnchor Slot.Dimensions: 16gage(l.5mm),14gage(1.9mm),or12gage(2.7mm)x 1inch(25mm)widex3-1/2inch(90mm),4-1/2inch(113mm), 5-1/2inch(138mm),or6-1/2inch(163mm)lengths (length does not include dovetail) Dovetailmeasures1inch(25mm)Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Otherlengthsandthicknessavailable. • Hasshearlugstoengageapieceofjointreinforcementeither Sei smic Ladur or Pencil Rod.

DA213 SEISMIC VENEER ANCHOR PLATESFunction: Designed to anchor masonry to a structure accommodating rigidinsulationupto3inches(75mm)thick.UsedwithDA213 SeismicPintlesorDA213QTLiteDutySeismicpintles.Dimensions: 14(1.9mm)or12(2.7mm)gagewithlegtoaccommodate thicknessofrigidinsulation.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Recommendtwofastenersperplate. • Needs3/4inch(19mm)to1inch(25mm)minimumaircavity. • Forattachmenttoconcrete,blockorbrickseeDA5213S. • Fullytested.

DA213 S SEISMIC VENEER ANCHOR PINTLESFunction: Designed to anchor masonry to a structure accommodating rigid insulation with provision for holding joint reinforcement in the veneer.UsedwithDA213PlatesandDA519Seismic Adjustable Eye Plates (Also Seismic Dur-O-Eye and Seismic Ladur-Eye).Dimensions: 12(2.7mm)and11(3mm)gagewith3-1/2inch(90mm)and 4-1/2inch(113mm)lengths2inches(50mm)widewitha 2inch(50mm)bentleg.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Otherlengthsavailable. • Hasshearlugstoengageapieceofjointreinforcement, either Seismic Ladur or Pencil Rod.

DA431 SEISMIC VENEER ANCHORFunction: Designed to anchor masonry to a structure particularly effective when air cavity is more than 1 inch (25mm).Dimensions: 14 (1.9mm) or 12 (2.7mm) gage x 1-1/4 inch (32mm) wide in 3-1/2 inch (90mm), 4-1/2 inch (113mm) and 5-1/2 inch (138mm) lengths.Finishes: Hot Dip Galvanized or Stainless Steel.Special Notes: • Has shear lugs to engage a piece of joint reinforcement, either Seismic Ladur or Pencil Rod. • For attachment to concrete, brick or block see DA5431. • Other lengths available.

Seismic Ties and Anchors

14

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Seismic Ties and Anchors

DA519 ADJUSTABLE SEISMIC WALL EYE PLATESFunction: Designed to tie multiwythe masonry walls with adjustability between wythes and allows for joint reinforcement in the veneer. Used with DA213SeismicPintles.Dimensions: 16gage(1.5mm)platewithlengthstoaccommodateuptoand including 3 inches of rigid insulation.Finishes: HotDipGalvanizedorStainlessSteel.

DA813 SEISMIC COMBSFunction: Designed to confine vertical bars at the ends of shear walls.Dimensions: 3/16inch(5mm)wireinaprescribedconfigurationofhooks for8inch(200mm),10inch(250mm)and12inch(300mm)CMU walls.Widthisapproximately1-1/4inches(30mm)lessthanthe thicknessoftheCMU. Length is approximately three times the actual width of the wall.Finishes: HotDipGalvanized.Special Notes: • MeetsrequirementsofmostBuildingCodes.

DA931 SEISMIC CHANNEL ANCHORSFunction: Designedtoanchormasonrytoastructure.UsedwithDA901, DA902,DA903,orDA904ChannelAnchorSlots.Dimensions: 16gage(l.5mm),14gage(1.9mm)or12gage(2.7mm)x1inch (25mm)widex3-1/2inch(90mm),4-1/2inch(113mm)or5-1/2inch (138mm)lengths(lengthdoesnotincludeChannelAnchor“T”).Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Hasshearlugstoengageapieceofjointreinforcement,either Seismic Ladur or Pencil Rod.

DA213QT LITE DUTY SEISMIC PINTLESFunction: Designed to anchor masonry to a structure with joint reinforcement intheveneer.UsedwithDA213VeneerAnchorPlates,DA518 Adjustable Cavity Wall Eyes, Dur-O-Eye or Ladur-Eye.Dimensions: 3/16inch(5mm)wirex3inch(75mm),4inch(100mm), 5inch(125mm),6inch(150mm),or7inch(180mm)lengthswith weldedQuakeTie(LengthsdonotincludetheQuakeTie)Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • HascliptoengageapieceofjointreinforcementeitherSeismic Ladur or Pencil Rod.

DA700QT LITE DUTY SEISMIC TRIANGULAR TIESFunction: Designed to anchor masonry to a structure with joint reinforcement intheveneer.UsedwithDA207MSSAVeneerAnchorScrew-on Straps,DA210VeneerAnchorScrew-onPlatesorDA709Column Anchor Weld-on.Dimensions: 3/16inch(5mm)wire3x3inches(75mmx75mm), 4x4inches(100mmx100mm),5x5inches(125mmx125mm), 6x6inches(150mmx150mm),7x7inches(180mmx180mm), and7x9inches(180mmx230mm)withweldedQuakeTie (LengthsdonotincludetheQuakeTie).Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • HascliptoengageapieceofjointreinforcementeitherSeismic Ladur or Pencil Rod. • QuakeTieisweldedinoff-setpositiontoenableTriangularTie tobeengagedtoDA207,DA210,orDA709.

15

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA720QT LITE DUTY SEISMIC DOVETAIL TRIANGULAR TIESFunction: Designedtoanchormasonrytoconcrete.UsedwithDA100 Dovetail Anchor Slot.Dimensions: 12gage(2.7mm)DovetailClipwith3/16inch(5mm)wiretiex 3-1/2inch(90mm),4-1/2inch(113mm),5-1/2inch(138mm), 6-1/2inch(163mm),7-1/2inch(193mm)and9-1/2inch (243mm)lengthswithweldedQuakeTie(lengthsdonot includeQuakeTie).Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Hasshearlugstoengageapieceofjointreinforcement either Seismic Ladur or Pencil Rod.

DA918QT LITE DUTY SEISMIC CHANNEL ANCHOR TRIANGULAR TIESFunction: Designedtoanchormasonrytoastructure.UsedwithDA901, DA902,DA903orDA904ChannelAnchorslot.Dimensions: 12gage(2.7mm)ChannelAnchorClipwith3/16inch(5mm) diameterwiretiex3-1/2inch(90mm),4-1/2inch(113mm), 5-1/2inch(138mm),6-1/2inch(163mm),7-1/2inch(193mm) and9-1/2inch(243mm)lengthswithweldedQuakeTie (lengthsdonotincludeQuakeTie).Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Hasshearlugstoengageapieceofjointreinforcement either Seismic Ladur or Pencil Rod.

DA320S SEISMIC LADUR (Masonry Reinforcement for Veneers)Function: Designed to provide greater ductility in veneers and is generally required in masonry veneers in seismic applications. Usedforblockorbrickveneerapplications.Dimensions: 9gage(3.7mm)wireforbothsideandcrossrods 5/8inch(15mm)out-to-outmeasurement 10feet8inch(3760mm)length.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Isalsoavailablein3/16inch(5mm)wireforsiderodsand 9gage(3.7mm)forcrossrods.

DA8706 PENCIL ROD DEFORMED (STRAIGHT AND CUT)Function: Designed to provide greater ductility in veneers and is generally required in masonry veneers in seismic applications. Usedasmasonryreinforcementforbrickveneers.Dimensions: 9gage(3.7mm)wirein10feet(3050mm)lengths.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • Isdeformedtocomplywithcoderequirementsfor joint reinforcement.

Seismic Ties and Anchors

16

FASTENER NOTE:Dur-O-Walrecommendstheappropriatefastenerbeusedwhenattachingveneeranchorstoastructuralbacking.Thefollowingfastenersarerecom-mended:

Use stainless steel screws with stainless steel anchors.•Use zinc corrosion protected screws with hot-dipped galvanized or mill galvanized anchors.•Attachveneeranchorstocast-in-placeconcrete,precastconcrete,holloworsolidconcretemasonryunits(CMU)usingeithertheDA5410or•DA5610ExpansionAnchors.Attachveneeranchorstoasteelstudorsheathingstructuralbacking,usingeithertheDA807SteelStudVeneerAnchorScreworDA995Stainless•Steel Screw.AttachveneeranchorstowoodstudandsheathingstructuralbackingusingtheDA808WoodStudScrew.•Never use nails to attach anchors.•

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Rebar Positioners and Other Products

DA810 REBAR POSITIONERSFunction: DesignedtopositionrebarverticallyinthecellofCMU.Dimensions: 9gage(3.7mm)wirefor6inch(150mm),8inch(200mm), 10inch(250mm)and12inch(300mm)CMU.Finishes: MillGalvanizedorHotDipGalvanized.Special Notes: Will accommodate up to and including #7 rebar.

DA811 REBAR POSITIONERSFunction: DesignedtopositionrebarverticallyincellofCMU.Dimensions: 18gage(1.2mm)steelfor8inch(200mm)CMUONLYFinishes: MillGalvanizedorHotDipGalvanized.Special Notes: • Will accommodate up to and including #7 rebar. • Will position 2 bars. • Can be installed after rebar is positioned in cell.

DA812 REBAR POSITIONERSFunction: DesignedtopositionrebarhorizontallyincellofCMU.Dimensions: 9gage(3.7mm)wirefor6inch(150mm),8inch(200mm), 10inch(250mm)and12inch(300mm)CMU.Finishes: MillGalvanizedorHotDipGalvanized.Special Notes: Will accommodate up to and including #7 rebar.

DA815 REBAR POSITIONERSFunction: DesignedtopositionrebarverticallyincellofCMU.Dimensions: 9gage(3.7mm)wirewith18gage(1.2mm)segmentsfor 6inch(150mm),8inch(200mm),10inch(250mm)and 12inch(300mm)CMU.Finishes: MillGalvanizedorHotDipGalvanized.Special Notes: • Will accommodate up to and including #7 rebar. • Will position 2 bars. • Can be installed after rebar is positioned in cell.

DA816 REBAR POSITIONERSFunction: DesignedtopositionrebarverticallyincellofCMU.Dimensions: 9gage(3.7mm)wirewith18gage(1.2mm)segmentsfor 8inch(200mm),10inch(250mm)and12inch(300mm)CMU.Finishes: MillGalvanizedorHotDipGalvanized.Special Notes: • Will accommodate up to and including #7 rebar. • Willposition4bars. • Can be installed after rebar is positioned in cell.

DA817 REBAR POSITIONERSFunction: DesignedtopositionrebarverticallyincellofCMU.Dimensions: 9gage(3.7mm)wirefor8inch(200mm),10inch(250mm), and12inch(300mm)CMU.Finishes: MillGalvanizedorHotDipGalvanized.Special Notes: • Willaccommodateuptoandincluding#8rebar. • Will position 2 bars. • Can be installed after rebar is positioned in cell. INSTALLATIONNOTEFORREBARPOSITIONERSBar positioners required by most Building Codes. Locate one positioner at top of first course,onecoursebelowtopofwallandatintervalsnotexceeding200bardiam-eters

17

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA1010 FIL-STOPFunction: Designedtocontrolloosefillinsulationinblockwallcells.Dimensions: 10TPIx10TPIMeshin150feet(45.72M)rollsin4inch (100mm),6inch(150mm),9inch(230mm)and12inch(300mm) actual widths.Special Notes: Fabricatedfromresincoatedfiberglass.

DA1015-DA1018 DUR-O-STOPFunction: Designed to prevent grout falling through while maintaining positive bond in mortar joint.Dimensions: 1/2inchx1/2inch(13mmx13mm)meshin100feet (30.48M)rollsfora6inch(150mm),8inch(200mm),10inch (250mm)and12inch(300mm)actualwidths.Actualmeasure- mentis2incheslessthantheblockinwhichitisinstalled.Special Notes: • Iscorrosionproofandbiologicallyinert. • Fabricatedfrommonofilamentscreenofnylon.

DA1020 DUR-O-FIBARFunction: AnadditivetoPortlandCementPlastertocontrolcracking in stucco.Dimensions: 1/2inch(13mm)fibers. Pre-measured1pound(454g)bags. Bulkpackagedin1,000pounds(534kg).Special Notes: Thisisanalkali-resistant(ARglass)additive.

DA2100 INS-O-GRIPSFunction: Designedtoholdrigidinsulationtightagainstbackupand provide cavity drip.Special Notes: Recommended for cavity drip instead of crimping or placing a “V”inthewirewhichweakensthesteel.

Rebar Positioners and Other Products

Loose Fill Insulation

Grout

18

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Stone Anchors

DA339

DA336

DA337

DA338

DA334

DA335

DA331

DA332

DA333

DA303

DA304

DA305

DA306

DA307

DA308

DA309

DA301U

DA301Z

DA101

DA102

DA911

DA913

DA914

DA917

DA103

DA201

DA203

DA204

DA205

STONE ANCHORSFunction: Designed to anchor stone panels to a structure, these Anchors can support dead loads, resist live loads and accom modate movement of the building envelope relative to the structure.

Dimensions: Thereareno“standard”dimensions. Anchors are individually engineered, detailed and manufactured per project drawing.

Finishes: BriteorPlainUncoated;MillGalvanized; HotDipGalvanized;StainlessSteel

Special Notes: Quotesandfabricationarebasedon approved details containing all dimensions.

19

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Movement Control Products

DA2001 REGULAR RUBBER CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrength,ElongationandDurometermeetsASTM D2000-08. • Recommendtobeusedinallexteriorwallswithbackerrod andcaulking/sealant. • Notrecommendedinfire-ratedwalls,unlessusedwithceramic insulationandfireresistantcaulking.

DA2003 #6 WIDE FLANGE RUBBER CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrength,ElongationandDurometermeetsASTM D2000-08. • Recommendedtobeusedininteriorwalls. • Notrecommendedforuseinfire-ratedwalls.

DA2005 #8 WIDE FLANGE RUBBER CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrength,ElongationandDurometermeetsASTM D2000-08. • For8inch(200mm),10inch(250mm)and12inch(300mm)CMU • Recommendedtobeusedininteriorwalls. • Notrecommendedforuseinfire-ratedwalls.

DA2025 RAPID “T” RUBBER CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrength,ElongationandDurometermeetsASTM D638-08. • Hasshearkeyonlyononesideofflange. • Notrecommendedforuseinfire-ratedwallsunlessusedwith ceramicinsulationandfireresistantcaulking.

DA2002 REGULAR PVC CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrengthandElongationmeetsASTMD638-08. • DurometerisinaccordancewithASTMD2240-05. • Recommendtobeusedinallexteriorwallswithbackerrod andcaulking/sealant. • PVCnotrecommendedforuseinfire-ratedwallsunlessusedwith ceramicinsulationandfireresistantcaulking.

DA2004 6 WIDE FLANGE PVC CONTROL JOINTFunction: Designed to control movement in concrete masonry unit with standardsashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrengthandElongationmeetsASTMD638-08. • DurometerisinaccordancewithASTMD2240-05. • Recommendedtobeusedininteriorwalls. • Notrecommendedinfire-ratedwalls.20

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Movement Control Products

DA2006 #8 WIDE FLANGE PVC CONTROL JOINTFunction: Designed to control movement in concrete masonry with standard sashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrengthandElongationmeetsASTMD638-08. • DurometerisinaccordancewithASTMD2240-05. • For8inch(200mm),10inch(250mm)and12inch(300mm)CMU’s. • Recommendedtobeusedininteriorwalls. • Notrecommendedinfireratedwalls.

DA2007 #12 WIDE FLANGE PVC CONTROL JOINTFunction: Designed to control movement in concrete masonry with standard sashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrengthandElongationmeetsASTMD638-08. • DurometerisinaccordancewithASTMD2240-05. • Hasanoffsetshearkey. • Notrecommendedinfireratedwalls.

DA2020 RAPID “T” PVC CONTROL JOINTFunction: Designed to control movement in concrete masonry with standard sashblockend.Dimensions: Eachpiecein32(810mm)or48inch(1220mm)lengths,blackcolor.Special Notes: • TensileStrengthandElongationmeetsASTMD638-08. • DurometerisinaccordancewithASTMD2240-05. • Hasshearkeyonlyononesideofflange. • Notrecommendedinfireratedwalls,unlessusedwithceramic insulationandfireresistantcaulking.

DA2010 RAPID SOFT JOINTFunction: Designedtokeepmortarandotherdebrisoutsideofhorizontaljoints, generallyundershelfangles,toallowforbrickexpansion.Dimensions: 1/4inch(6mm)thickx23/4inch(70mm)widex50feet(15.24M)rolls. Otherthicknessandwidthsavailable.Special Notes: • Closedcellneoprenerubber. • Adhesiveononesidewithareleasecoateddisposablebackingpaper. • MeetsASTMD1056-00,ClassRE41or2A1.

DA2015 RAPID EXPANSION JOINTFunction: Designedtokeepmortarandotherdebrisoutsideofverticaljointsto allowforbrickexpansion.Dimensions: 3/8inch(10mm)thickx3inch(75mm)widex50feet(15.24M)rolls. Otherthicknessandwidthsavailable.Special Notes: • ClosedcellneopreneRubber. • MeetsASTMD1056-00,ClassRE41or2A1.

DA2200 JOINT STABILIZING ANCHORFunction: Designed to allow movement at expansion, contraction or isolation joints in masonry while maintaining the wall alignment in a direction normal to the movement.Dimensions: 1/32inch(1mm)sheetsteelsleevesandtwo8gage(4mm)wires.Finishes: • MillGalvanizedandStainlessSteel.

DA411 WALL TOP STABILIZING ANCHORFunction: A mechanical anchor designed to resist lateral loads at the top ofmasonrywallsandallowforliveloadverticaldeflection.Dimensions: 3/8inchx6inch(10mmx150mm)steeldowelvertically weldedto12gage(2.7mm)steelplate.Finishes: HotDipGalvanized.Special Notes: • Concealedwithinapartitionwallwithnoexposedhardware.Installed by welding or with mechanical anchors, such as DUR-O-WAL Expansion Anchor fasteners in concrete. 21

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Moisture Control Products

DA1501 DCF THRU-WALL FLASHINGFunction: Designedasthru-wallflashingformasonrywalls.Dimensions: 300feet(91.4M)Rollsavailablein12inch(300mm),16inch (400mm),18inch(457mm),24inch(600mm),36inch(915mm) and48inch(1220mm)widths.Special Notes: • Compositeflashingofvinylethylenefilmbondedtoafiber glass reinforcement. • Recommenduseofmastictosealedges,splicesand cover punctures.

DA1502 DCF FLASHING TAPEFunction: Designedtoattachflashingtosubstrate,torepairandseal punctures or perforations and for splices.Dimensions: 2inch(50mm)widex108feet(32.9M)rolls.

DA1505 COPPER FABRIC THRU-WALL FLASHINGFunction: Designedasthru-wallflashingformasonrywalls.Dimensions: 25feet(7.6M)rollsin3,5and7ouncecopperavailablein 12inch(300mm),16inch(400mm),18inch(457mm),24inch (600mm),32inch(810mm),and36inch(915mm)widths.Special Note: • Coppersheetisasphaltcoatedonbothsidesandbonded between two layers of high tensile fiberglass fabric.

DA1506 COPPER KRAFT DUPLEX FLASHINGFunction: Designedflashingforconcealedroofflashingandforvapor barrier and slab on grade.Dimensions: 60feet(18.2M)rollsin3,5and7ouncecopperavailablein 12inch(300mm),16inch(400mm),18inch(457mm), 24inch(600mm),and36inch(915mm)widths.Special Note: • Coppersheetislaminatedunderhighpressurewithonelayer ofasphaltsaturatedwith60poundkraftpaperoneachside. • 7oz.availableonSpecialOrder-subjecttominimum quantities.

DA1507 COPPER COATED THRU-WALL FLASHINGFunction: Designedasthru-wallflashingformasonrywalls.Dimensions: 25feet(7.6M)rollsin3,5and7ouncecopperwiithvarious widths.Special Note: • Coppersheetiscoatedonbothsideswithapolymer modified asphalt compound. • SpecialOrder:subjecttominimumquantities.

DA1508 PVC SHEETINGFunction: Designed as a concealed waterproofing membrane on foundation walls and under concrete slabs.Dimensions: 150feet(45.7M)rollsin20miland30milavailablein12inch (300mm),16inch(400mm),18inch(457mm),24inch(600mm), and36inch(915mm)and48inch(220mm)widths.Special Note: Not recommended or endorsed for use as above grade thru-wall flashing.

22

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA1540 POLY-BARRIER THRU-WALL FLASHINGFunction: Designedasthru-wallflashingformasonrywalls.Dimensions: 50feet(15.2M)rollsin40mil(32milrubberizedasphaltplus 8milpolyethylenefilm)availablein12inch(300mm),16inch (406mm),18inch(457mm),24inch(600mm)and36inch (915mm)width.Special Notes: • Self-sealing,self-healing,fully-adheredcompositeflexibleflashing. • RecommendDripEdgeStainlessSteelFlashingbeused.

DA1544 DUR-O-BARRIER THRU-WALL FLASHINGFunction: Designedasthru-wallflashingformasonrywalls.Dimensions: 75feet(22.8M)rollsin44mil(32milrubberizedasphaltplus 12milpolyethylenesheet)availablein12inch(300mm), 18inch(457mm),24inch(600mm)and36inch(915mm)width.Special Notes: • Self-sealing,self-healing,fully-adheredcompositeflexible flashing. • RecommendDripEdgeStainlessSteelFlashingbeused.

DA1510 TERMINATION BARFunction: Designedtoattachflashingtoabacking.Dimensions: 1/8inch(3mm)thickx11/2inch(38mm)widex8feet (2440mm)lengthswithholesat8inches(200mm)oncenter.Finishes: Stainless Steel.Special Notes: Holesizeis5/16inch(8mm)diameter.

DA1525 DRIP EDGE FLASHINGFunction: Designedasamoisturebarriertousewiththru-flashingsuch asDCFFlashing,CopperFlashing,Dur-O-BarrierandPoly Barrier.Dimensions: 26gage(0.45mm)x8feet(2440mm)lengthsx1-1/2inch (38mm)widewith3/8inch(10mm)closedhemmededgeFinishes: Stainless Steel.Special Notes: FullDripEdgewideenoughtobridgethelengthofthe horizontal leg of the lintel or shelf angle is available with hemmed edge only.

DA1005 WEEP HOLES OR TUBESFunction: Designed to be placed in head joints to allow air to enter cavity.Dimensions: 3/8inch(10mm)outsidediameterin4inch(100mm)and 8inch(200mm)lengthsofclearplastic.Special Notes: • Weep holes are subject to clogging with mortar droppings, silt and bugs. • Recommend cavity contain mortar dropping control devices and cell vents.

DA1006 CELL VENTSFunction: Cell vent consists of many small adjacent passageways bonded together in one unit. Cellular composition provides easy drainage for moisture along the full height of the head joint. Recommended for use incoursedirectlyontopofflashing.Dimensions: Standard3/8inchx2-1/2inchesx3-3/8inches (10mmx64mmx85mm). Jumbo3/8inchx3-5/8inchesx3-5/8inches (10mmx92mmx92mm).Special Notes: • AvailableinClear,Almond,Black,Brown,Cocoa, GrayandWhite. • Recommend cavity contain mortar dropping control devices.

Moisture Control Products

23

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Moisture Control Products

DA1007 MOR-CONTROLFunction: Designed to control mortar droppings to insure clear air spaces in cavity walls.Dimensions: 16inch(400mm)lengthtoaccommodate1inch(25mm), 1-1/2inch(38mm)and2inch(50mm)aircavities.Special Notes: • Fabricatedfromwhitecorrugatedpoly-propylene co-polymer plastic in white.

DA1008 MORTAR NET™Function: Designed to control mortar droppings to insure clear air spaces in cavity walls.Dimensions: 10inch(250mm)widex5feet(1.5M)lengthsto accommodate1inch(25mm)and2inch(50mm)aircavities.Special Notes: • 1”widthfabricatedfromeitherhighdensitypolyethyleneor 100%polyester.2”widthmanufacturedfrom50%recycled polyester.

DA1009 MORTAR-STOP™Function: Designed to control mortar droppings to insure clear air spaces in cavity walls.Dimensions: 10inch(250mm)wide50feet(15.2M)lengths to accommodate any air cavity.Special Notes: • Fabricatedfromhighdensitypolyethylene.

DA2016 DUR-O-BARRIER TAPESFunction: Designed to be placed between sheathing and veneer anchor plates or straps to minimize moisture penetration.Dimensions: 4inch(100mm)widex100feet(30.4M)rolls.Special Notes: • Hasareleasecoateddisposablebacking.

24

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DA3200 LADUR JOINT REINFORCEMENTFunction: Designedtoreinforceglassblockmasonrybyplacementin horizontal mortar joint.Dimensions (1): 9gage(3.7mm)wireforsideandcrossrods. #3measures1-5/8inches(46mm)out-to-out. #4measures2inches(50mm)out-to-out. CrossRodsspaced16inches(400mm)oncenter. 10feet8inch(3760mm)length.Dimensions (2): 9gage(3.7mm)wireforsideandcrossrods. #3measures1-5/8inches(46mm)out-to-out. #4measures2inches(50mm)out-to-out. CrossRodsspaced8inches(200mm)oncenter. 10feet(3050mm)length.Dimensions (3): 9gage(3.7mm)wireforsideandcrossrods. #3measures1-5/8inches(46mm)out-to-out. #4measures2inches(50mm)out-to-out. CrossRodsspaced8inches(200mm)oncenter48inch (1220mm)length.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • MillGalvanizedisnotrecommendedforglassblock masonry construction.

DA1070 GLASS BLOCK PANEL ANCHORSFunction: Designedtoanchorglassblocktoadjacentstructure.Dimensions: 20gage(0.91mm)x1-3/4inchesx24inches (44mmx600mm)perforatedsteelstrip.Finishes: HotDipGalvanizedorStainlessSteel.Special Notes: • MillGalvanizedisnotrecommendedforglassblockmasonry construction.

DA8706 PENCIL ROD SMOOTH (STRAIGHT AND CUT)Function: Designedforverticalreinforcementinglassblockmasonry. construction.Dimensions: 1/4inch(6mm)smoothwirein10feet(3050mm)lengthsFinishes: HotDipGalvanizedorStainlessSteel.Special Notes: • MillGalvanizedisnotrecommendedforglassblockmasonry construction.

Glass Block Masonry Accessories

25

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL SINGLE WYTHE SYSTEMS DA3100 TRUSS AND DA3200 LADUR

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints ofmasonrywallsineitherDA3100TrussorDA3200Ladurtypes.

Basic Uses: • Tocontrolshrinkagecracking. • Tobondintersectionwalls. • Toprovideprincipalsteelinengineeredmasonrywalls. • Toreinforcestackbondmasonry.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthan thenominalthicknessofthewytheorwallinwhichthereinforcementistobeplaced. • Trussisprovidedin10feet(3050mm)lengthswithCrossRodswelded16inches (400mm)oncenter. • Ladurisprovidedin10feet8inchlengths(3250mm)withCrossRodswelded16inches (400mm)oncenter[15inches(380mm)oncenterisavailablein10feet(3050mm)lengths].

Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm) Cross Rods.

Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes: PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x32inches (810mm).

Single Wythe Systems

26

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Multi-Wythe Systems

DUR-O-WAL MULTIWYTHE NON-ADJUSTABLE SYSTEMS DA3100TR TRUSS TRIROD, DA3100DSR TRUSS DOUBLE SIDE ROD, DA3200TR LADUR TRIROD AND DA3200DSR LADUR DOUBLE SIDE ROD

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonrywallsineitherDA3100TrussorDA3200Ladurtypes.

Basic Uses: • Tocontrolshrinkagecracking. • Tobondintersectionwalls. • Toprovideprincipalsteelinengineeredmasonrywalls. • Toreinforcestackbondmasonry. • Tiesmultiwythemasonrywalls. • Trirodprovides2siderodsinbackingand1siderodinveneerwall. • DoubleSideRodprovides2siderodsinbackingand2siderodsinveneer.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthan thenominalthicknessofthewytheorwallinwhichthereinforcementistobeplaced.

• Trussisprovidedin10feet(3050mm)lengthswithCrossRodswelded16inches(400mm) on center. • Ladurisprovidedin10feet8inchlengths(3250mm)withCrossRodswelded16inches (400mm)oncenter[15inches(380mm)oncenterisavailablein10feet(3050mm)lengths].Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm)CrossRods.

Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • Alwayschecklocalbuildingcodesforrequirements. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteelorHot DipGalvanized.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes: • PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x32inches (810mm)andCornersmustbedesignatedasOutsideorInsideCorners. • DUR-O-WALdoesnotrecommendTrussTrirodorTrussDoubleSideRodininsulated cavity walls due to differential movement. • TrirodandDoubleSideRodshouldonlybeusedwhenthewythescourseout.

27

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL MULTIWYTHE NON-ADJUSTABLE SYSTEMS DA3500 DUR-O-TAB AND DA3400 CONTINUOUS RECTANGULAR TAB TIE (CRT)

Function: Prefabricated reinforcement designed for embedment in the horizontal mortarjointsofmasonrywallsineitherDA3500Dur-O-TaborDA3400CRTtypes.

Basic Uses: • Tocontrolshrinkagecracking. • Tobondintersectionwalls. • Toprovideprincipalsteelinengineeredmasonrywalls. • Toreinforcestackbondmasonry. • Tiesmultiwythemasonrywalls. • WeldedrectangulartabsonthesiderodsoftheTrussdesignDA3500Dur-O-TaborLadur designDA3200CRTareembeddedintheveneer.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthanthe nominalthicknessofthebackingandtheoverallwidthoftheassemblyshouldbesuch thatthetabtieextendsatleast1-1/2inches(38mm)intotheouterwythe. • Standardlengthis10feet(3050mm)withtherectangulartabsweldedat16inches (400mm)oncenter.

Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm)CrossRods. • RectangularTabsarefabricatedfrom3/16inch(5mm)wire.Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteel orHotDipGalvanized. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes: • PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x32 inches(810mm)andCornersmustbedesignatedasOutsideorInsideCorners. • Dur-O-TabandCRTshouldonlybeusedwhenthewythescourseout.

Multi-Wythe Systems

28

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Multi-Wythe Adjustable Systems

DUR-O-WAL MULTIWYTHE ADJUSTABLE SYSTEMSDA3700 DUR-O-EYE AND DA3600 LADUR-EYE

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonrywallsineitherDA3700Dur-O-EyeorDA3600Ladur-Eyetypes.

Basic Uses: • Providessameusesassinglewythewalls. • Tiesmultiwythemasonrywalls. • WeldedeyesonthesiderodsoftheTrussdesignDA3700Dur-O-EyeorLadurdesign DA3600Ladur-Eyeengagepintlestotiethewytheswithadjustabilitybetweenwythes.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthan thenominalthicknessofthebackingandtheoverallwidthoftheassemblyshouldbe suchthattheengagedpintlesextendatleast1-1/2inches(38mm)intotheouterwythe. • MaximumplaybetweenPintleengagedinEyeis1/16inch(2mm). • Pintlelegallowsforamisalignmentof1-1/4inches(30mm). • Standardlengthis10feet(3050mm)withtheEyesweldedat16inches(400mm)oncenter.

Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm)CrossRods. • EyesandPintlesarefabricatedfrom3/16inch(5mm)wire.

Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteelor HotDipGalvanized. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes: • PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x32inches (810mm)andCornersmustbedesignatedasOutsideorInsideCorners. • Pintlescanbeinstalledeitherupordown. • 2-1/2”maximummisalignmentbetweencourseswhichwillmeetthecoderequirements. • ThesesameguidelinesapplytoDUR-O-WAL’sInLineLadur-Eyetoutilizeitsadvantages.

29

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL SEISMIC JOINT REINFORCEMENTDA3700S SEISMIC DUR-O-EYE AND DA3600S HEAVY DUTY SEISMIC LADUR-EYE

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonrywallsineitherDA3700SDur-O-EyeorDA3600SSeismicLadur-Eyetypes

Basic Uses: • Providessameusesassinglewythewalls. • Tiesmultiwythemasonrywallsinseismicapplications. • WeldedeyeplatesonthesiderodsoftheTrussdesignDA3700SSeismicDur-O-Eyeor LadurdesignDA3600SSeismicLadur-EyeengageSeismicPintlestotiethewytheswith adjustability between wythes.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthan thenominalthicknessofthebackingandtheoverallwidthoftheassemblyshouldbesuch thattheengagedSeismicPintlesextendatleast1-1/2inches(38mm)intotheouterwythe. • SeismicPintlelegallowsforamisalignmentof1-1/4inches(30mm). • Standardlengthis10feet(3050mm)withtheEyesPlatesweldedat16inches(400mm)on center.

Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm)CrossRods. • EyesPlatesarefabricatedfrom16gage(1.5mm)sheetsteel. • SeismicPintlesarefabricatedfromeither12gage(2.7mm)or11gage(3.0mm)sheetsteel.

Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteelor HotDipGalvanized. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes:• PrefabricatedCornersandTeesareavaiableandmeasure32inches(810mm)x32inches (810mm)andCornersmustbedesignatedasOutsideorInsideCorners. • SeismicPintlescanbeinstalledeitherupordown2-1/2”maximummisalignmentbetween courses which will meet the code requirements. • ShearLugsattheendoftheSeismicPintleengageapieceofjointreinforcementor pencil rod.

Seismic Joint Reinforcement

30

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Seismic Joint Reinforcement

DUR-O-WAL SEISMIC JOINT REINFORCEMENTDA3700ES LITE DUTY SEISMIC DUR-O-EYEDA3600ES LITE DUTY SEISMIC LADUR-EYE

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonrywallsineitherDA3700ESLiteDutySeismicDur-O-EyeorDA3600ESLiteDuty Seismic Ladur-Eye types.

Basic Uses: • Providessameusesassinglewythewalls. • Tiesmultiwythemasonrywalls. • WeldedeyesonthesiderodsoftheTrussdesignDA3700ESLiteDutySeismicDur-O-Eye orLadurdesignDA3600ESLiteDutyLadur-Eyeengagepintlestotiethewytheswith adjustability between wythes.

Dimensions: • Outtooutspacingofdeformedsiderodsisapproximately2inches(50mm)lessthanthe nominalthicknessofthebackingandtheoverallwidthoftheassemblyshouldbesuch thattheengagedpintlesextendatleast1-1/2inches(38mm)intotheouterwythe. • MaximumplaybetweenengagedpintleinEyeis1/16inch(2mm). • Pintlelegallowsforamisaligmentof1-1/4inches(30mm). • Standardlengthis10feet(3050mm)withtheEyesweldedat16inches(400mm)oncenter.

Wire Gages: • StandardWeight9gage(3.7mm)SideRodsand9gage(3.7mm)CrossRods. • ExtraHeavyWeight3/16inch(5mm)Siderodand9gage(3.7mm)CrossRods. • SuperHeavyWeight3/16inch(5mm)Siderodsand3/16inch(0.187or5mm)CrossRods) • Eyesandpintlesarefabricatedfrom3/16inch(5mm)wire.

Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteelorHot DipGalvanized. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes: • PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x32inches (810mm)andCornersmustbedesignatedasOutsideorInsideCorners. • Pintlescanbeinstalledeitherupordown2-1/2”totalforadjustmentbetweencourses, whichwillmeetthecoderequirementsallowingfor2-1/2”maximummisalignment between courses. • WeldedQuakeTieatendofpintleengagesapieceofjointreinforcementorpencilrod.

31

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL SEISMIC JOINT REINFORCEMENTDA8706 PENCIL ROD DEFORMED (STRAIGHT AND CUT)

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of veneer walls.

Basic Uses: • Tocontrolshrinkagecracking. • Toprovidegreaterductilityinveneers.

Dimensions: Deformed10feet(3050mm)lengths.

Wire Gages: StandardWeight9gage(3.7mm)ExtraHeavyWeight3/16inch(or5mm).

Finishes: BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications including veneers. Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Bettercrackdistributionunderseismicloads. • Highbondbecauseofthedeformations.

Seismic Joint Reinforcement

32

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Seismic Joint Reinforcement

33

Seismic Joint Reinforcement

DA3200S SEISMIC LADUR JOINT REINFORCEMENT

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonry walls.Basic Uses: • Tocontrolshrinkagecracking. • Tobondintersectionwalls. • Toprovideprincipalsteelinengineeredmasonrywalls. • Toreinforcestackbondmasonry. • Toprovidegreaterductilityinveneers.

Dimensions: 5/8inch(15mm)out-to-outmeasurement10feet8inch(3760mm)length.Wire Gages: • StandardWeight9gage(3.7mm)Side Rodsand9gage(or3.7mm)crossrods. • ExtraHeavyWeight3/16inch(or5mm) Siderodsand9gage(or3.7mm)crossrods. • SuperHeavyWeight3/16inch(or5mm) Siderodsand3/16inch(or5mm)crossrods

Finishes: HotDipGalvanizedorStainlessSteel.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing: • Bettercrackdistributionunderseismicloads. • Greaterelasticity. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength. • Installationeasebyallowingjointreinforcementtobeplacedoneithersideofverticalrods inblockveneers.

Special Notes: SeismicLadurisgenerallytherecommendedjointreinforcementinblockveneersandinveneers widerthan4”nominal.

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WAL RANDOM/RUBBLE STONE SYSTEM DA3300SL ADJUSTABLE DUR-O-TAB WITH RESTRAINT BAR DA3000SL ADJUSTABLE RECTANGULAR TAB TIE WITH RESTRAINT BAR (CRT) J-BARS AND DA700WB SERIES TRIANGULAR TIES WITH RESTRAINT BAR

Function: Prefabricated reinforcement designed for embedment in the horizontal mortar joints of masonrywallsineitherDA3300SLDur-O-TaborDA3000SLCRTtypes.

Basic Uses: • Providessameusesassinglewythewalls. • Tiesmultiwytheblockwalltorandom/rubblestoneveneer. • TriangulartabswithrestraintbarsareweldedonthesiderodsoftheTrussdesign DA3300SLDur-O-TaborLadurdesignDA3300SLCRTtotiewytheswithadjustability between the wythes. • J-BarsandTriangularTieswithweldedRestraintBarscombinationprovidesversatilityfor tyingtheveneertotheblockback-up.

Dimensions: • Out-to-outspacingofdeformedsiderodsisapproximately2inches(50mm)lessthanthe nominalthicknessofthebacking. • Standardlengthis10feet(3050mm)withtheTabsweldedat16inches(400mm)oncenter. • J-Barsare52inches(1320mm)length.

Wire Gages: Tests show continuous reinforcement improves masonry wall performance by providing:

• Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength. • TabsandTriangularTiesare3/16inch(5mm)wire. • J-Barsare3/8inch(10mm)rod.Finishes: • BriteBasic,MillGalvanized,HotDipGalvanizedandStainlessSteel. • DUR-O-WALrecommendsMillGalvanizedforInteriorapplications,(notglassblock). • DUR-O-WALrecommendsHotDipGalvanizedforallExteriorapplications,including glassblockmasonryandwhereMeanRelativeHumidityexceeds75%. • MultiwythewallsareconsideredexteriorapplicationsandshouldbeStainlessSteelor HotDipGalvanized. • Alwayschecklocalbuildingcodesforrequirements.

Advantages: Tests show continuous reinforcement improves masonry wall performance by providing:

• Crackcontrol. • Greaterelasticity. • Butt-welded,singleplaneconstruction. • Highbondwiththedeformedsiderods. • Betterresistancetorainpenetration. • Increasedhorizontalflexuralstrength.

Special Notes:PrefabricatedCornersandTeesareavailableandmeasure32inches(810mm)x3inches (810mm)andCornersmustbedesignatedasOutsideorInsideCorners.

Random/Rubble Stone System

34

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

35

Reinforcing RequirementsBuilding codes generally define reinforced masonry by re-quiring that the sum of the areas of horizontal and vertical re-inforcement be at least 0.002 times the gross cross-sectional area of the wall with the minimum in either direction not less than 0.0007 times the wall area. Reinforcement is also limited to a maximum spacing of 4 feet (1220mm) on center.

DUR-O-WAL Truss and Ladur Type joint reinforcements may be considered part of the required minimum horizontal reinforcement.

In many cases, the steel requirement can be satisfied entirely by the use of DUR-O-WAL products and/or will reduce the amount of steel required in bond beams to meet code requirements. It should be noted, that the codes also require sufficient steel reinforcement to resist all live and dead loads imposed upon the structure. But even when more than the minimum steel is required, the use of DUR-O-WAL joint rein-forcement, as a part of this steel, will reduce the number of bond beams needed.

MINIMUM AREA OF HORIZONTAL STEEL REQUIRED TO SATISFY CODE REQUIREMENTS*

NominalWallThicknessin/(mm) 4”(100) 6”(150) 8”(200) 10”(250)12”(300)14”(350) 16”(400) 18”(450) 20”(500)22”(550) 24”(600)

GrossAreain2/ft. (mm2/m) 43.50 67.5 91.50 115.5 139.5 163.5 187.5 211.5 235.5 259.5 283.5 (92,000) (140,276)(193,522)(244,282)(295,042)(345,802)(396,562)(447,322)(498,082)(548,842)(599,602)

Total area of steel in2/ft (mm2/m) 0.087 0.135 0.183 0.231 0.279 0.327 0.375 0.423 0.471 0.519 0.567 .002xGrossArea (184.0) (285.5) (387.0) (488.6) (590.0) (691.6) (793.1) (894.6) (996.2) (1097.7) (1199.2)

HorizontalSteel 0.030 0.047 0.064 0.081 0.098 0.114 0.131 0.148 0.165 0.182 0.198Required in2/ft (mm2/m) (63.5) (99.4) (135.4) (171.3) (207.3) (241.1) (277.1) (313.0) (349.0) (385.0) (418.8)

AREA OF STEEL SUPPLIED BY DUR-O-WAL LADUR TYPE REINFORCEMENT* in2/ft (mm2/m) Vertical Spacing 2-#9 Side Rods 2-3/16” Side Rods 4-#9 Side Rods 4-3/16” Side Rods

8” (200) .052 (110.0) .083 (175.5) .104 (220.0) .166 (351.1)

16” (400) .026 (55.0) .041 (86.7) .052 (110.0) .083 (175.5)

REINFORCEMENT FOR BOND BEAM AT TOP OF 8” & 12” CM WALLS WHEN DUR-O-WAL LADUR IS USED*

*Compare area of steel required with area supplied by DUR-O-WAL Ladur or Truss

*Regular DUR-O-WAL Truss can also be used to provide reinforcement. Diagonal cross wires may interfere with grout and reinforcing steel place-ment.DUR-O-WALrecommendstheuseofLadurMasonryReinforcementwhenawallistobeverticallyreinforcedand/orgrouted.

*RequestDUR-O-WALpublications;ReinforcingMasonryWallsWithJointReinforcement,ADesignAid,Bulletin83-7,BuildingReinforcedMasonryWallswithJointReinforcement,Bulletin84-10.ReinforcingShearWallswithJointReinforcement,Bulletin85-12R.ForinformationontheuseofDUR-O-WALtoresisthorizontalbending,MasonryReinforcementinHigh-Rise,BearingWallBuildings,Bulletin74-6.

Dur-O-Wal Specifications

Ladur Spacing 8” Wall (200) 12” Wall (300) Type 8’(2400) 12’ (3660) 16’ (4880) 20’ (6100) 24’ (7310) 8’ (2400) 12’ (3660) 16’ (4880) 20’ (6100) 24’ (7310)

Standard 8” (200) O.C. 1#4 1#5 1#5 2#4 1#6 1#6 1#7 1#8 2#7 1#10Weight 16” (400) O.C. 2#4 1#7 1#8 2#6 2#7 1#7 2#6 2#7 2#8 2#9

Extra Heavy 8” (200) O.C. 1#3 1#3 1#4 1#4 1#4 2#4 1#7 1#8 2#6 1#9Weight 16” (400) O.C. 1#5 1#6 1#7 1#8 2#6 1#7 2#6 2#7 2#8 2#9

Super Heavy 8” (200) O.C. 1#3 1#3 1#3 2#3 1#3 1#3 1#5 1#5 1#6 1#7 Weight 16” (400) O.C. 2#3 1#5 1#6 1#7 2#5 1#7 1#8 2#7 2#7 2#8

Random/Rubble Stone System

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

Dur-O-Wal Specifications

SELECTION TABLE FOR DUR-O-WAL TRUSS** Design Types Weight Classifications Wall Widths Effective Areas in2 (mm2) per 10ft of Truss and wire sizes Single Composite or Wythe Cavity

Singlewythe Class Side Cross Overall Overall Backup No.3 No.4 No.6 No.8 No.10 No.12 No.13 No.14 No.16 No.18 No.20 Composite Rods Rods Wall Wall Wall (for3” (for4” (for6” (for8” (for10” (for12” (for13” (for14”(for16” (for18”(for20”

or Cavity* Width Width Width wall) wall) wall) wall) wall) wall) wall) wall) wall) wall) wall)

Dur-O-WalTrussStandardNo.9 No.9 3”to20” .052 .051 .050 .048 .047 .045 .045 .044 .043 .042 .042

W1.7 W1.7 (75to (33.6) (32.9) (33.6) (31.0) (30.3) (29.0) (29.0) (28.4) (27.7) (27.1) (27.1)

500)

Extra 3/16” No.9 .073 .072 .071 .069 .068 .066 .066 .065 .064 .063 .062

Heavy W2.8 W1.7 (47.1) (46.5) (45.8) (44.5) (43.9) (42.6) (42.6) (41.9) (41.3) (40.6) (40.0)

Dur-O-WalTrussStandardNo.9 No.9 8”to24”3”to12” Notmadefor .066 .064 .063 .062 .061 .060 .060 .059

Trirod W1.7 W1.7 (200to (75to 3”,4”,6”walls (42.6) (41.3) (40.6) (40.0) (39.4) (38.7) (38.7) (38.1)

600) 300)

Extra 3/16” No.9 Notmadefor .097 .095 .094 .093 .093 .092 .091 .090

Heavy 3”,4”,6”walls (62.6) (61.3) (60.6) (60.0) (60.0) (59.4) (58.7) (58.1)

Dur-O-WalTrussStandard No.9 No.9 10”to24”3”to12” Notmadefor .081 .080 .079 .079 .078 .077 .076

DoubleSideRod W1.7 W1.7 (250to (75to 3”,4”,6”,8”walls (52.3) (51.6) (51.0) (51.0) (50.3) (49.7) (49.0)

600) 300)

Extra 3/16” No.9 Notmadefor .123 .122 .121 .120 .119 .119 .118

Heavy W2.8 W1.7 3”,4”,6”,8”walls (79.4) (78.7) (78.1) (77.4) (76.8) (76.8) (76.1)

*When cavities are insulated, check for effect or differential movement** Effective area of DUR-O-WAL Truss, Trirod and Double includes side rods plus an allowance for the tensile resistance of the diagonal cross rods which is equal to the diagonal cross rod area times the cosine of the angle between the diagonal cross rod and side rod.

SELECTION TABLE FOR DUR-O-WAL LADUR Design Types Weight Classifications Wall Widths Effective Areas in2 (mm2) per 10ft of Ladur and wire sizes Single Composite or Wythe Cavity

Singlewythe Class Side Cross Overall Overall Backup No.3 No.4 No.6 No.8 No.10 No.12 No.13 No.14 No.16 No.18 No.20 Composite Rods Rods Wall Wall Wall (for3” (for4” (for6” (for8” (for10” (for12” (for13” (for14”(for16” (for18”(for20”or Cavity* Width Width Width wall) wall) wall) wall) wall) wall) wall) wall) wall) wall) wall)

Dur-O-WalLadur StandardNo.9 No.9 3”to20” .0346 .0346 .0346 .0346 .0346 .0346 .0346 .0346 .0346 .0346 .0346 W1.7 W1.7 (75to (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) (22.3) 500) Extra 3/16” No.9 .0554 .0554 .0554 .0554 .0554 .0554 .0554 .0554 .0554 .0554 .0554 Heavy W2.8W1.7 (35.7) (35.7) (35.7) (35.7) (35.7) (35.7) (35.7) (35.7) (35.7) (35.7) (35.7)

Dur-O-WalLadur StandardNo.9 No.9 8”to24”3”to12” Notmadefor .0519 .0519 .0519 .0519 .0519 .0519 .0519 .0519Trirod W1.7W1.7 (200to (75to 3”,4”,6”walls (33.5) (33.5) (33.5) (33.5) (33.5) (33.5) (33.5) (33.5) 600) 300) Extra 3/16” No.9 Notmadefor .0831 .0831 .0831 .0831 .0831 .0831 .0831 .0831 Heavy 3”,4”,6”walls (53.6) (53.6) (53.6) (53.6) (53.6) (53.6) (53.6) (53.6)

Dur-O-WalLadur Standard No.9 No.9 10”to24”3”to12” Notmadefor .0692 .0692 .0692 .0692 .0692 .0692 .0692DoubleSideRod W1.7W1.7 (250to (75to 3”,4”,6”,8”walls (44.6) (44.6) (44.6) (44.6) (44.6) (44.6) (44.6) 600) 300) Extra 3/16” No.9 Notmadefor .1108 .1108 .1108 .1108.1108 .1108.1108 Heavy W2.8W1.7 3”,4”,6”,8”walls (71.5) (71.5) (71.5) (71.5) (71.5) (71.5) (71.5) *When cavities are insulated, check for effect or differential movement

36

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

SELECTION TABLE FOR DUR-O-WAL TRUSS** Design Types Weight Classifications Wall Widths Effective Areas in2 (mm2) per 10ft of Truss and wire sizes Single Composite or Wythe Cavity

Singlewythe Class Side Cross Overall Overall Backup No.3 No.4 No.6 No.8 No.10 No.12 No.13 No.14 No.16 No.18 No.20 Composite Rods Rods Wall Wall Wall (for3” (for4” (for6” (for8” (for10” (for12” (for13” (for14”(for16” (for18”(for20”

or Cavity* Width Width Width wall) wall) wall) wall) wall) wall) wall) wall) wall) wall) wall)

Dur-O-WalTrussStandardNo.9 No.9 3”to20” .052 .051 .050 .048 .047 .045 .045 .044 .043 .042 .042

W1.7 W1.7 (75to (33.6) (32.9) (33.6) (31.0) (30.3) (29.0) (29.0) (28.4) (27.7) (27.1) (27.1)

500)

Extra 3/16” No.9 .073 .072 .071 .069 .068 .066 .066 .065 .064 .063 .062

Heavy W2.8 W1.7 (47.1) (46.5) (45.8) (44.5) (43.9) (42.6) (42.6) (41.9) (41.3) (40.6) (40.0)

Dur-O-WalTrussStandardNo.9 No.9 8”to24”3”to12” Notmadefor .066 .064 .063 .062 .061 .060 .060 .059

Trirod W1.7 W1.7 (200to (75to 3”,4”,6”walls (42.6) (41.3) (40.6) (40.0) (39.4) (38.7) (38.7) (38.1)

600) 300)

Extra 3/16” No.9 Notmadefor .097 .095 .094 .093 .093 .092 .091 .090

Heavy 3”,4”,6”walls (62.6) (61.3) (60.6) (60.0) (60.0) (59.4) (58.7) (58.1)

Dur-O-WalTrussStandard No.9 No.9 10”to24”3”to12” Notmadefor .081 .080 .079 .079 .078 .077 .076

DoubleSideRod W1.7 W1.7 (250to (75to 3”,4”,6”,8”walls (52.3) (51.6) (51.0) (51.0) (50.3) (49.7) (49.0)

600) 300)

Extra 3/16” No.9 Notmadefor .123 .122 .121 .120 .119 .119 .118

Heavy W2.8 W1.7 3”,4”,6”,8”walls (79.4) (78.7) (78.1) (77.4) (76.8) (76.8) (76.1)

The BRACE-RITE™ System Pipe Braces are available in three sizes to support various masonry wall height dimensions.

When ordering BRACE-RITE braces, indicate the brace designation and application type. BraceapplicationtypesapplytoBR20,BR23andBR39designations.

*Safe Working Load based on a safety factor of 1.5.

TYPE I

BRACE

DESIGNATION DESCRIPTIONLENGTH

ADJUSTMENT RANGE

BRACE-RITEBR20 Regular Pipe Brace 13’-0”to20’-6”

BRACE-RITE BR23 HeavyDutyRegularPipeBrace 14’-6”to23’-6”

BRACE-RITEBR39 HeavyDutyLongPipeBrace 22’-6”to39’-0”

Safe Working Loads for Braces*BRACE

LENGTH

BRACEDESIGNATION

BR20 BR23 BR39

13’-0” 5,800lbs. NA NA

14’-0” 5,000lbs. NA NA

15’-0” 4,200lbs. 6,500lbs. NA

16’-0” 3,460lbs. 6,500lbs. NA

17’-0” 2,975lbs. 6,270lbs. NA

18’-0” 2,750lbs. 5,250lbs. NA

19’-0” 2,275 lbs. 4,100lbs. NA

20’-0” 1,975lbs. 3,575 lbs. NA

21’-0” NA 2,880lbs. NA

22’-0” NA 2,410lbs. NA

23’-0” NA 2,080lbs. 5,585lbs.

24’-0” NA NA 4,905lbs.

25’-0” NA NA 4,250lbs.

26’-0” NA NA 3,325 lbs.

27’-0” NA NA 2,715lbs.

28’-0” NA NA 2,280lbs.

29’-0” NA NA 1,850lbs.

30’-0” NA NA 1,600lbs.

31’-0” NA NA 1,250lbs.

TYPE II

TYPE III

TYPE IV

BRACE-RIGHT System

37

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

38

BRACE-RIGHT™ SystemDA800MP MOUNTING PLATE MountingPlateconnectstowallfaceandbearsonthebracesideofthewall.Itismanufacturedfrom3/8”thicksteelplateconformingtoASTMA36.Thepipebraceisattachedwitha5/8”diameterbuttonheadpin.

DA800BP and DA800SBP BACKING PLATE BackingPlateisinstalledontheunbracedsideofthewall.TheBackingPlateismanufacturedfrom3/8”steelplateconformingtoASTMA36.TheDA800BPisusedwhenthebraceisattacheddirectlytothewall.Twoslotsare provided to accommodate the Wall Ties which are inserted through the bedjointsofthewall.TheDA800SBPStrongbackBackingPlateisinstalledontheunbracedsideofthewallwhenastrongbackisused.Oneslotisprovided to accommodate the Wall Tie which is inserted through the head joint of the wall.

DA800WT WALL TIES WallTiesconnectthemountingplatetothebackingplatethroughthewall.Theyaremanufacturedfromhighstrengthsteel.Thesafeworkingloadis3,000poundswiththeapproximatefactorofsafetyof2to1.Thewalltiesareavailableintwosizes.DA800WT610accommodates6”and10”block.DA800WT812isusedwith8”and12”block.

DA800ST STRONGBACK TIESStrongbackTiesareusedtotiestrongbackstothewall.DA800ST610ac-commodates6”and10”CMUplusthestrongback.DA800ST812isusedwith8”and12”CMUandthestrongback.

DA800W WEDGES Wedgesaremanufacturedfrom3/16”highcarbonsteelformaximumgrip-ping strength.

DA800BC Brace Clip Brace Clip connects the brace to an aluminum horizontal strut or strong-back.Itismanufacturedwith3/8”steelplateconformingtoASTMA36.Thesafeworkingloadis3,000lbs.Attachbracecliptostrongbackorstrutwith1/2”diameter,Grade5boltandnut.

DA800FB Floor Bracket FloorBracketcastingconnectsthebracetoaconcreteslab,foundationordeadman.UsewithDA800CACoilAnchor.SafeWorkingLoadis6,500lbs.

Basedontheapproximatefactorofsafetyof1-1/2to1.

DA800SBP

DA800BP

STRONGBACK TIE

WALL TIE

5-1/4”

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

39

BRACE-RIGHT™ System

DA800CA Coil Anchor3/4”x4-1/2”longCoilAnchorisusedtoattachthefloorbrackettocon-cretefloorslabordeadman.UsewithDA0800FB.

DA800FC Foundation ClipFoundationClipisusedtoconnectthehorizontalstruttoadeadman,sledorotherabovegradeanchorage.Itismanufacturedfrom3/8”steelplateconformingtoASTMA36.Fastentoconcretewithtwo1/2”anchorbolts.

DA800S Strongbacks and StrutsStrongbacks and Struts are extruded from 6061-T6 structural aluminum. Tubes are punched to allow for attachment of brace and foundation clips as well as wall ties.

The Strongback is a vertical stiffening beam that is attached to the wall on the brace side of the wall. It is typically used when the vertical bend-ing strength of the wall is not adequate to resist wind load between brace points. The Strongback is attached to the wall with a DA800ST Strongback Tie located in vertical head joints at 4’-0” spacing. Strong-back ties are attached to DA800SBP Backing Plates on the opposite side of the wall. Individual tubes can be spliced with DA800SP Splice Plates to form strongbacks that are 20”, 24” or 28” long. The Strongback has a section modulus of 2.0 In.3 and a bending moment safe working load capacity of 2,500 lb. ft.

The Strut is a horizontal member used to transfer horizontal brace loads to the wall foundation when the brace anchor does not have the ca-pability to resist horizontal loads itself. Struts are generally used with concrete deadmen above grade.

DA800SC

DA800S

DA800SP

DA800SBC

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

40

Restoration Anchors

DUR-O-WAL has a complete line of quality restoration products that includes a variety of mechanical and friction pinning anchors as well as replacement systems for seismic and non-seismic applications.

Someofthemorepopularanchorsareshownherewithbriefinformation.Additionaltypesavailable.Foradditional information request a copy of the Dur-O-Wal Masonry Repair Handbook(dow2).

DA5000 MECHANICAL ANCHOR SERIESFunction: Designedtorestrainveneerstobackingmaterials ofsolidconcrete,brick,solidCMUandstone.

DA5100 MECHANICAL ANCHOR SERIESFunction: Designedtorestrainveneerstobackingmaterial ofbrick,hollowCMU,solidCMU,stone,claytile and precast concrete.

DA5300 MECHANICAL ANCHOR SERIESFunction: Designedtorestrainveneerstobackingmaterial of wood stud, steel stud and wood sheathing.

DA508 DUR-O-FLEX FRICTION PINNING ANCHORFunction: Designedforvarietyofbackingmaterialsfor wall tying applications that typically would use masonry connectors of the light to medium duty variety.

DA5213; DA5213 S; DA5431; DA5801 BRICK REPLACEMENT ANCHORSFunction: Designedtoreplacebrickinretrofitapplicationsandtoanchorveneersin newconstructiontoconcrete,blockandbrickbackingsandintomortarjoints. Eachanchorisprovidedwitha7/16inch(11mm)ExpansionAnchor FastenerwhichcomesassembledonthePlateorAnchorfor2inches(50mm) embedmentinbacking.Finishes: HotDipGalvanizedorStainlessSteelfortheAnchorparts. ExpansionAnchorFastenerconsistsofeitheraCarbonSteelorStainlessSteel. 1/4”-20NCHexHeadBoltwithWasherandaBrassSleeveandBrassExpanderCone.

DA5213S

DA5213

DA5431

DA5801

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

DUR-O-WALmasonryproductsareintendedforusebytrained,qualifiedandexperiencedworkmenonly.Misuseorlackofsupervision and/or inspection can contribute to serious accidents or deaths. Any application other than those shown in this publication should be carefully tested before use.

TheuserofDUR-O-WALproductsmustevaluatetheproductapplication,determinethesafeworkingloadandcontrolallfieldconditionstopreventapplicationsofloadsinexcessofaproduct’ssafeworkingload.Thesafetyfactorsshowninthispublica-tionareapproximateminimumvalues.Thedatausedtodevelopsafeworkingloadsand/orusageratesforproductsdisplayedinthispublicationareacombinationofactualtestingand/orotherindustrysources.Recommendedsafeworkingloadsand/orusage rates, if given for the products in this publication, must never be exceeded.

Worn Working PartsForsafety,masonryaccessoriesmustbeproperlyusedandmaintained.Masonryaccessoriesshowninthispublicationmay be subject to wear, overloading, corrosion, deformation, intentional alteration and other factors that may affect the de-vice’sperformance.Allreusableaccessoriesmustbeinspectedregularlybytheusertodetermineiftheymaybeusedattheratedsafeworkingloadorshouldberemovedfromservice.Thefrequencyofinspectionsdependsuponfactorssuchas(butnot limited to) the amount of use, period of service and environment. It is the responsibility of the user to schedule accessory hardware inspections for wear and remove the hardware from service when wear is noted.

Shop or Field ModificationWeldingcancompromisethesafeworkingloadvalueandcausehazardoussituations.Knowledgeofmaterials,heat-treating and welding procedures is necessary for proper welding. Consult a local welding supply dealer for assistance in determining required welding procedures.

SinceDUR-O-WALcannotcontrolworkmanshiporconditionsinwhichmodificationsaredone,DUR-O-WALcannotberesponsible for any product altered in the field.

InterchangeabilityManymasonryaccessoryproductsthatDUR-O-WALmanufacturesaredesignedaspartofasystem.DUR-O-WALstronglydiscourages efforts to interchange products supplied by other manufacturers with components supplied by DUR-O-WALWhen used properly, and in accordance with published instructions, DUR-O-WAL products have proven to be among the best designed and safest in the industry. Used improperly or with incompatible components supplied by other manufacturers, DUR-O-WAL products or systems may be rendered ineffective and/or unsafe.Design Changes

DUR-O-WALMasonryAccessoriesreservestherighttochangeproductdesigns,ratedloadsandproductdimensionsatany time without prior notice.

Safety Information

General DisclaimerThe information contained in this publication does not consti-tute any professional opinion or judgement and should not be used as a substitute for competent professional determina-tions.

Each construction project is unique and the appropriate use of this product is the responsibility of the engineers, architects, and other professionals who are familiar with the specific re-quirements of the project.

General WarrantySellermakesnowarrantyofanykind,exceptthatthegoods sold under this agreement shall be of the stan-dardqualityoftheseller,andbuyerassumesallriskandliability resulting from the use of the goods, whether used singly or in combination with other goods. Seller neither assumes nor authorizes any person to assume for seller any other liability in conjunction with the sale or use of the goods sold, and there is no oral agreement or warranty collateral to or affecting this transaction.

41

D A Y T O N S U P E R I O R . C O M • B U I L D I N G S T R E N G T H

We have the most complete dealer network in North America. For the dealer nearest your project, simply call the office in your region.

B U I L D I N G S T R E N G T H

D A Y T O N S U P E R I O R C O R P O R A T I O N7 7 7 7 W A S H I N G T O N V I L L A G E D R I V E , S U I T E 1 3 0

D A Y T O N , O H 4 5 4 5 9P H O N E : 9 3 7 - 4 2 8 . 6 3 6 0

T O L L F R E E : 8 7 7 - 6 3 2 . 9 8 6 6F A X : 9 3 7 - 4 2 8 . 9 5 6 0

D A Y T O N S U P E R I O R . C O M

GREAT PLAINS DISTRICTKansas City4226 Kansas AvenueKansas City, KS 661061-877-416-3439

ELK GROVE VILLAGE