Dunlee OEM Catalog

20
OEM Product Catalog Your worldwide source for X-ray components

Transcript of Dunlee OEM Catalog

Page 1: Dunlee OEM Catalog

OEMProduct Catalog

Your worldwide source for X-ray components

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 1

Page 2: Dunlee OEM Catalog

The complete solution for improving your image

PP rroodduucctt oovveerrvviieeww

HHiigghh--vvoollttaaggee CCaabblleess

GGeenneerraattoorrss

XX--rraayy TTuubbeess

BBuucckkyy UUnniitt FFaammii llyy

II mm aaggee IInntteennssiiffiieerrss IIoonniizzaattiioonn CChhaammbbeerrss

DDiissppllaayyss

22

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 2

Page 3: Dunlee OEM Catalog

OOEEMM pprroodduuccttss

Product overview 2

Table of contents 3

Portfolio 4 – 5

X-Pack 6 – 7

Displays 8

Image Intensifiers 9

Bucky Unit Family 10

Ionization Chambers 11

Grids 12

Patient Tables 13

Table Tops 14

Collimators 15

X-ray Tubes 16

High-voltage Cables 17

Generators 18

wwwwww..dduunnlleeee..ccoomm

TTaa bbllee ooff ccoonntteennttss

CCoollll iimmaattoorrss

TTaa bbllee TTooppss

PPaattiieenntt TTaa bblleess

GGrriiddss

33

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 3

Page 4: Dunlee OEM Catalog

44

Portfolio

Choose from advance displays, image intensifiers,

components of the Bucky unit family, ionization

chambers, grids, patient tables, tabletops, collimators,

tubes, high-voltage cables and generators.

We can also assemble tailor-made packages for you.

For example, the X-Pack contains a complete set of

fluoroscopic components ready to be incorporated

into your system. Select any combination of components

and have them supplied in your colors and with your

name. Our components are made by world-renowned

companies, including Philips, Smit Röntgen, and FIMI,

in addition to our Dunlee tubes.

Dunlee distributes high-quality

X-ray components found

at the heart of your system

Tap into the power of Dunlee for all your imaging component needs.

Dunlee is the X-ray components supplier of choice for original equipment

manufacturers.We provide all X-ray system products with the best possible

technology and the ability to market them profitably.

Dunlee distributes the high-quality X-ray components

found at the heart of your system – those that

determine the overall image quality. We offer

components for conventional and digital radiography

systems, remote-controlled and conventional

radiographic fluoroscopic systems and urology and

litho systems.

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 4

Page 5: Dunlee OEM Catalog

55

Worldwide Service Strong background

Listening to you and understanding your

needs in a personal atmosphere is our team’s

goal.We draw on comprehensive logistics

background, local presence and experience,

as well as the expertise from our plants in

Europe and America.

With offices around the world, Dunlee is in

a unique position to service X-ray manu-

facturers on five continents. Just contact our world

headquarters or one of our three customer centers.

They can give you the name of the Dunlee office closest

to you.After placing your order, our reliable and durable

products are made available to you around the globe.

You can expect nothing less than superior quality for

every single item. Plus, benefit from our one-stop shop

and extensive technical support.

Contact our world headquarters or one of our three customer centers.

Dunlee has over 60 years of technical proficiency in all

X-ray fields, including CT, Cardio, RF and radiography.

Each component contains proof of its unique technology.

These truly state-of-the-art products and your

manufacturing skills will allow your customers to

succeed with world-class image quality.

Dunlee is backed by more than 100 years of experience

from Philips Medical Systems. As part of Philips, we have

systems knowledge at our fingertips, one of this global

player’s greatest strengths. Our systems knowledge flows

into our components to benefit you and your customers.

WWoorrlldd HHeeaaddqquuaarrtteerrss

Dunlee

555 North Commerce Street

Aurora, IL 60504, USA

Tel: +1 630 585 2100

Fax: +1 630 585 2125

EEuurrooppeeaann CCuussttoommeerr CCeenntteerr

Dunlee

Marbacher Straße 114

40597 Düsseldorf, Germany

Tel: +49 211 7705890

Fax: +49 211 203000

CCuussttoommeerr CCeenntteerr &&

RReellooaaddiinngg FFaacciilliittyy

2312 Avenue J

Arlington,Texas 76006 USA

Tel: +1 817 640 7666

Fax: +1 817 640 6644

CCuussttoommeerr CCeenntteerr &&

RReellooaaddiinngg FFaacciilliittyy

8819 Whitepine Road

Richmond,Virigina 23237 USA

Tel: +1 804 714 2501

Fax: +1 804 714 2507

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 5

Page 6: Dunlee OEM Catalog

X-PackX-Pack is your ability to configure tested and proven

X-ray system components to meet your application and

functionality. X-Pack consists of components critical to

your system´s operation, starting from the generator and

ending with the image display.You can select from

3 different generator power ratings, generator features

for radiographic or R/F functionality, Image Intensifier

sizes, image processing functions and displays.Any or

all of the devices will be configurated to your needs,

your color and your interface.All this backed up by the

expertise of Philips Healthcare.

Small / large focus 0,6 / 1,5 0,3 / 0,6 0,3 / 0,6Fixed anode Rot.Anode 3000 Rpm Rot.Anode 3000 Rpm

Monobloc heat capacity in J / HU 500 kJ / 700 KHU 600 kJ / 810 KHU 600 kJ / 810 KHU

Monobloc weight (kg) 15,0 21,5 21,5

Cont. heat dissipation 70 W 75 W 75 W

Anode angle (monobloc) 16° 10° 10°

Pulsed Fluoro 3,6 or 12 F/sec I = 30 mA I = 30, 60 mA I = 30, 60 or 120 mA(T pulse = 20 msec) (30 mA large focus) (30, 60 mA small focus) (30, 60 mA small focus)

(60, 120 mA large focus)

Continuous fluoroscopy 40–110 kV 40–120 kV 40–120 kV

mA range low dose/high dose 0,2–5 mA low 0,2–5 mA low 0,2–5 mA low0,4–10 mA high 0,4–10 mA high 0,4–10 mA high

AAppppll iiccaattiioonn 33,,55 kkWW 77,,55 kkWW 1155 kkWW

GGeenneerraattoorr ttyyppee 33,,55 kkWW 77,,55 kkWW 1155 kkWW

66

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 6

Page 7: Dunlee OEM Catalog

X-ray detectionSSttaannddaarrdd OOppttiioonnaall

Fluoro package

LIH (Last Image Hold)

ABC (Automatic Brightness Control)

Dose measuring field area correction

X-ray dose level

Noise reduction

Edge enhancement

Horizontal / vertical flipWhite compressionAGC (Automatic Gain Control)

B/W Invert

Plus package

Electronic zoom

Contrast / brightness control

DICOM grey scale

Extended memory: 125 can be stored(Image size = 1.5 MB / 12 bit deep)

Surgery package

RotationDescription: rotation of the image correcting the image orientation (due to C-arm angulation)User controllable: yes, 0–360 ° in steps of 8 °

Customized package

On request

77

X-Pack: System features

Extended memory 125 images can be stored (image size =1.5 MB/12 bit deep)

Dual monitor output Optional (for live & reference image)

RS 644 & DVI Optional (RS 644 and / or DVI are mutually exclusive.Both outputs at the same time are not possible.)

Camera Camera 1 k Optional typical resolution

Image intensifier II 12" Optional fluoro version

II 9" Optional (exposure version) with

Automatic Exposure Control AECvia phototimer

II 12" Optional (exposure version) withAutomatic Exposure Control AECvia phototimer

Remote control desk 8,4" TFT touch display (operates in master / slave)

Control desk via host PC Generator system Ctrl.Adapted via RS232/CAN to the OEM host PC. Other communications on request

Display LCD On request

Video output (standard) Analog video output: CCIR (50 Hz) or EIA (60 Hz)

Camera Camera 0,5 k Standard typical resolution

Image intensifier II 9" Standard (fluoro version)

X-ray grid Stationary grid (removable or fixed) 60 lines/cm ratio 10 SID and color on request

Collimator (for surgery) With Iris and rectangular shutters (lead shutters)With Iris and rectangular shutters (copper shutters=semi transparent)

Collimat AM With lead rectangular shutters for RF application

Control desk 8,4" TFT touch display design and configurable layout

Area dose low dose/high dose The value will be calculated or measured (optional) via Ion chamber

SSttaannddaarrdd

OOppttiioonnss

p_Dunlee_Catalog 18.02.2008 7:49 Uhr Seite 7

Page 8: Dunlee OEM Catalog

DisplaysWe offer FIMI displays for a wide range of requirements

and specific applications.The product portfolio includes

color and monochrome LCD and a wide selection of

screen sizes from 18 to 21 inches. All products have

been designed to meet the requirements of the

International Medical Standards for safety and EMI/RFI

(medical grade displays). FIMI developed proprietary

technologies such as Triple Gun Technology, CyberScreen

Technology and Magnetometer.The result is a no

compromise display range perfect for professional users

of high performance medical imaging systems.

PPaa rrtt nnoo.. PP rroodduucctt ttyyppee DDeessccrriippttiioonn

991932050616 MML1801 18" LCD monochrome

991932050633 MCL1801 18" LCD color

991932051011 MML1921 19.6" 2MP - 8 bit grayscale

991933050401 RAD2MP RAD2MP Graphic Board bundled

991933050401 RAD2MP RAD2MP Graphic Board only

991932051011 MML1921 19.6" 2MP - 10 bit grayscale

991933050341 MED2MP MED2MP Graphic Board bundled

991933050341 MED2MP MED2MP Graphic Board only

991932051241 MML2032 20.8" 3MP - 10 bit grayscale

991933050452 MED3MP MED3MP Graphic Board bundled

991933050452 MED3MP MED3MP Graphic Board

991932051251 MML2152 21.3" 5MP - 10 bit grayscale

991933050462 MED5MP MED5MP Graphic Board bundled

991933050462 MED5MP MED5MP Graphic Board

88

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 8

Page 9: Dunlee OEM Catalog

99

Image IntensifiersPhilips invented the first Image Intensifier in 1952 and

has continued to develop and refine its technology.

Today, our image intensifiers are the gold standard for

performance in the healthcare industry.They provide

superior image quality, higher image uniformity, effective

magnetic shielding and a long lifetime. In addition, the

Flxis (Flexible X-ray Imaging System) product line offers

integrated subsystems. Flxis comprises an image

intensifier, a high-resolution camera, and built-in image

processing for fluoroscopy and digital exposure

applications.With this concept, time and money can be

saved:You will be able to decrease on-site engineering

and integration costs, as well as life cycle maintenance

costs.

FLXIS

9"/23cm multi-mode 25mm glass output

12"/31cm multi-mode 25mm glass output

16"/38cm multi-mode 35mm glass output

AAsssseemmbblliieess::II mm aaggee IInntteennssiiffiieerr,, CCoonnttaaiinneerr,, PPoowweerr SSuuppppllyy

Fluoroscopy package

Surgery package

Plus package

Cardio/Vascular package

Overlay package

II mm aaggee pprroocceessssiinngg ppaacckkaaggeess

Dual monitor output

Extended memory

Direct control interface

RS 644 / DVI

OOtthheerr ooppttiioonnss

9''/23 cm Image Intensifier Assembly 0.5k2 or 1k2 CCD-Camera

12''/31 cm Image Intensifier Assembly 0.5k2 or 1k2 CCD-Camera

16''/38 cm Image Intensifier Assembly 1k2 CCD-Camera

SSuubbssyysstteemmss::II mm aaggee IInntteennssiiffiieerr AAsssseemmbbllyy,, CCCCDD CCaammeerraa

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 9

Page 10: Dunlee OEM Catalog

The Bucky unit family can be used with all conventional

diagnostic systems. Dunlee offers a wide range of

sensing and non-sensing cassette trays which support

conventional and digital CR cassettes.

• Bucky Unit 2 non-Sensing

• Bucky Unit 2 Sensing (non CAN)

• Bucky Unit 2 Sensing (CAN-CAL)

The Bucky tray supports all metric and inch cassettes

starting from 18 x 24 cm (8 x 10 inches) to 35 x 43 cm

(14 x 17 inches).The grid can be easily removed, allowing

for different applications with different SIDs.

Bucky Unit Family

Length 584,5 mm 23.0"

Width 506 mm 19.9"

Heigth 77 mm 3.0"

Weight 29 kg 63.9 lb

MMeecchhaanniiccaall DDaattaa

specified / displayed specified / displayed

18 cm 8"

20 cm 9.5"

24 cm 10"

30 cm 11"

35 cm 12"

40 cm 14"

43 cm 17"

CCaasssseettttee ddiimmeennssiioonnssCCaasssseettttee ssiizzeess ((iinn ccmm)) CCaasssseettttee ssiizzeess ((iinn iinncchheess))

1100

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 10

Page 11: Dunlee OEM Catalog

1111

Ionization ChambersIIoonniizzaattiioonn mmeeaassuurriinngg cchhaammbbeerrss

The ionization chambers measure the dose rate in the

region of interest set for the patient.When a preset dose

has been reached, the downstream electronic control

system terminates exposure automatically. Philips

ionization chambers come in various shapes, sizes, and

measuring field positions, according to the application.

TTyyppeess ooff mmeeaassuurriinngg ffiieellddss ffoorr BBuucckkyy ssyysstteemmss

Part no.

9890 000 01615

Part no.

9890 000 70003

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 11

Page 12: Dunlee OEM Catalog

The Smit Röntgen product range comprises both

standard grids and grids designed for special applications.

The low absorption gives a higher DQE with detectors in

digital applications and a significant dose advantage over

aluminum interspaced grids. Our grids can be delivered

with any focal distance between 70 cm and 300 cm.

Standard grids are covered with two aluminum plates

each 0,5 mm thick. As an option our grids can be

delivered with carbon fiber covers instead of the

aluminum plates. Other dimensions, shapes, line rates

and ratios are possible. Smit Röntgen grids are available

exclusively from Dunlee.

Grids

36 lines / cm 90 lines / inch ratios 8:1, 10:1, 12:1

44 lines / cm 110 lines / inch ratios 8:1, 10:1, 12:1, 15:1

60 lines / cm 150 lines / inch ratios 10:1, 13:1, 15:1

70 lines / cm 178 lines / inch ratio 13:1

CCiirrccuullaarr ggrriiddssDDiiaammeetteerr:: 118800 –– 442200 mmmm

FFii llmmssiizzee // DDiiggiittaall ggrriiddss1133 xx 1188 ccmm –– 4400 xx 112200 ccmm

36 lines / cm 90 lines / inch ratios 8:1, 10:1, 12:1

44 lines / cm 110 lines / inch ratios 8:1, 10:1, 12:1, 15:1

60 lines / cm 150 lines / inch ratios 10:1, 13:1, 15:1

70 lines / cm 178 lines / inch ratio 13:1

BBuucckkyy ggrriiddssOOvveerraallll ssiizzee:: 448800 –– 443388 mmmm

36 lines / cm 90 lines / inch ratios 8:1, 10:1, 12:1

40 lines / cm 103 lines / inch ratios: 8:1, 10:1, 12:1, 15:1

44 lines / cm 110 lines / inch ratios 8:1, 10:1, 12:1, 15:1

60 lines / cm 150 lines / inch ratios 10:1, 13:1, 15:1

70 lines / cm 178 lines / inch ratios 13:1, 17:1

80 lines / cm 203 lines / inch ratios: 15:1

31 lines/cm 77.5 lines / inch ratio 5:1

41 lines/cm 102.5 lines / inch ratio 6:1

MM aa mm mm ooggrraapphhyy ggrriiddss 1188xx2244 ccmm aanndd 2244xx3300 ccmm

1122

p_Dunlee_Catalog 15.02.2008 9:29 Uhr Seite 12

Page 13: Dunlee OEM Catalog

1133

FFrreeeeLLiinnee

The FreeLine table combines all the requirements

of conventional and digital radiography including an

elevating (motorized) and floating table top.

Patient TablesDunlee offers a range of patient tables designed to satisfy your customer needs.

SSppeeeeddLLiinnee

The mobile SpeedLine elevating patient table with

floating table top, operates without electrical energy

sources.

FFrreeeeLLiinnee

Length 2600 mm 102.4"

Width 750 mm 29.5"

Height (electric adjustable) 510 mm – 905 mm 20.1" – 35.6"

Floating longitudinal (x) 0 – 400 mm 0 – 15.8"

Floating transverse (y) +/- 200 mm +/- 7.9"

Max.patient weight 225 kg 496 lb

X-ray transparent area length 1680 / 2100 66.1" / 82.7"

X-ray transparent area width 465 mm / 750 mm 18.3" / 29.5"

X-ray absorption factor <1.4 mm AL

Dimension (l x w) 2600 mm x 750 mm 102.4" x 29.5"

Operating voltage 230 VAC 50/60 Hz

Length 2271 mm 89.4"

Width 673 mm 26.5"

Height (adjustable) 600 mm – 800 mm 23.6" – 34.1"

Floating longitudinal (x) unlimited unlimited

Floating transverse (y) +/- 100 mm +/- 3.9"

Weight 129 kg 284.4 lbs

Max.patient weight 225 kg 496 lb

X-ray transparent area 1730mm x 670mm/620 mm 68.1" x 26.4" / 24.4"

X-ray absorption factor <1.2 mm AL

Dimension (l x w) 2200mm x 670mm/620mm 86.6" x 26.4" / 24.4"

SSppeeeeddll iinnee

TTaa bbllee TToopp

TTaa bbllee TToopp

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 13

Page 14: Dunlee OEM Catalog

Table Tops

With the best performance, quality and price LRS

Composites produces a wide variety of tabletops

for medical systems and has done so for more than

30 years.

Philips Medical Systems has the most extensive appli-

cation and composite knowledge for tabletops in X-ray

and MRI systems.This is proven by an excellent track

record with regard delivery, performance and quality.

Customized tabletops are available on request.

1144

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 14

Page 15: Dunlee OEM Catalog

1155

CollimatorsDunlee’s easy to use collimators feature a compact

design and extraordinary ease of use.The Format M is a

manual collimator with near-focus shutters that can be

controlled.The Collimat AM is a motorized manual

collimator which can be easily interfaced to any system.

Manual collimator for radiographic applications

Dimensions (h x w x l): 6.1 x 8 x 11.3 inches / 155 x 203 x 286 mm

Regulation with safety standards: IEC, DHHS, UL

Integral 30s timer switch, SID measurement

Rotatable flange with 90° lock-in positions

FFoorrmmaatt MM PP rroodduucctt ttyyppee PPaarrtt nnoo..

Electric powered collimator for radiographic and R/F applications

Light beam lamp: 24V / 150W halogen

Actual value sensor 1kOhm

Rotatable flange with 90° lock-in positions

Not for sale in US market

CCooll ll iimmaatt AA MM

Format M 9896 010 22151

Format M/SI 9896 010 22261

Format M/P 9896 010 22271

Format M/SIP 9896 010 22291

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 15

Page 16: Dunlee OEM Catalog

Dunlee X-ray tubes are manufactured in some of the

most advanced production centers in the world, including

Hamburg, Germany and Aurora, USA.Tubes from Dunlee

offer optimal performance, high-heat dissipation

capabilities and unique ball-bearing constructions.

Most new tube units include a trunnion ring assembly.

Other X-ray tube models are available on request.

X-ray Tubes

PP rroodduucctt ttyyppee TTaarrggeett kk WW kk WW AAnnooddee kk VV5500 HHzz 115500 HHzz kkHHUU

DA 1002 15˚ 1.0 / 2.0 33/73 55/120 300 150

DA 1029 13.5˚ 0.6 / 1.2 18/60 31/93 300 150

DA 1036 13.5˚ 0.6 / 1.2 18/60 31/93 400 150

DA 1082 15˚ 0.6 / 1.0 14/32 23/55 400 150

DA 1092 12˚ 0.6 / 1.2 18/60 31/93 600 150

DA 1094 15˚ 0.4 / 0.8 9/28 17/42 600 150

DR 1436 13.5˚ 0.6 / 1.2 19/60 33/95 400 150

DR 1492 12˚ 0.6 / 1.2 - 40/100 600 150

DR 1494 14˚ 0.4 / 0.8 - 15/45 600 150

DR 1817 13˚ 0.6 / 1.2 17/50 - 300 150

DR 1825 15˚ 0.6 / 1.0 16/30 25/50 300 150

DR 1833 13˚ 0.6 / 1.2 20/60 33/100 300 150

DU 1750 DA 90 13˚ 0.6 / 1.2 17/50 - 300 150

DU 2550 DA 90 HS 15˚ 0.6 / 1.0 16/30 25/50 300 150

DU 3050 DA 90 16˚ 0.6 / 1.8 30/50 - 300 150

DU 33100 DA 90 HS 13˚ 0.6 / 1.2 20/60 33/10 300 150

1166

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 16

Page 17: Dunlee OEM Catalog

1177

High-voltage CablesWe are a leading supplier of high-voltage cables for

X-ray systems. Our high-voltage cables are designed for

medical applications from basic radiology systems up to

high performance cardiovascular systems. Our products

range from competitive standard cables to solutions for

special applications. Dunlee produces high-voltage cables

for voltages up to 250 kV. Safety, quality and flexibility are

our greatest priorities, enabling us to meet all of our

customers’ needs.The product features we offer include

a 3-pin high-voltage plug and a 3-conductor high-voltage

cable. Other characteristics and connector configurations

are available upon request.

Rated voltage 75 kV DC

Number of contact pins 3

Jacket color Light-grey

Jacket O. D. 16,20 ± 0,38 mm

Insulation O. D. 13,00 ± 0,25 mm

Coverage of shield 95 %

Min. bending radius (static/dyn.) 50/65 mm

Conductor resistance @ 20°C 11,5 m/m

Core to Shield Capacitance 154 ± 10% pF/m

High voltage insulation test 120/10 kV DC/min

Conductor insulation test 2/1 kV DC/min

Operating temperature -10 / + 110 °C

Weight 0.43 kg/m

HHiigghh--vvoollttaaggee ccaabblleess

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 17

Page 18: Dunlee OEM Catalog

The Optimus generator has been and continues to be

one of the most reliable units in operation today.With

its modern ergonomic design it provides consistent

operation for all radiographic and fluoroscopic

applications.With over 15,000 units installed, the

Optimus is a robust, proven component, providing the

highest quality images available. The Optimus offers a

wide range of functions and features.

Second tube connection

Variofocus

Patient data organizer (PDO)

Anatomically programmed radiography (APR)

Automatic exposure control (AEC)

Tomo time input

Tomo density control

OOppttiioonnss

Power range 50 kW, 65 kW, 80 kW

Radiography 40 kV – 150 kV

Exposure time down to 1 ms

Fluroscopy 0.1 mA – 6mA / 40 kV – 125 kV

Quick fluroscopy 0.2 s – 0.4 s

depending on absorption

SSppeecciiff iiccaattiioonnss

1188

Generators

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 18

Page 19: Dunlee OEM Catalog

2

Dunlee Sales, Service, and Manufacturing Locations

Dunlee Sales Office Locations

Dunlee European Customer CenterMarbacher Strasse 114D-40597 Düsseldorf, GermanyTel: +49 211 7705890Fax: +49 211 203000

Sales Office Central-East EuropeBelgradeSerbiaTel: +38 11 132 4 3390Fax: +38 16 32 8921

Regional Sales OfficeSouth-Europe and Middle EastMonza (MI) ItalyTel: +39 0392036536Fax: +39 0392419430

Sales Office North-West EuropeFranceTel: +33 1 6990 7233Fax: +33 1 6990 7233

Regional Sales OfficeBrazilRua Verbo Divino1.400-Saõ PauloChácara Sto AntonioTel: +55 11 2125 3426Fax: +55 11 2125 3432

Regional Sales Office Beijing10F., The Place Tower, No. 9, Guanghua Road, Chaoyang District, Beijing 100020, ChinaTel: +86 10 65172288 3979 +86 10 85273979Fax: +86 10 65017380

Dunlee European Customer CenterMarbacher Strasse 114D-40597 Düsseldorf, GermanyTel: +49 211 7705890Fax: +49 211 203000

Aurora Facility555 North Commerce StreetAurora, Illinois 60504 USATel: +1 800 238 3780 (U.S. & Canada)

+1 630 585 2100Fax: +1 630 585 2125

Richmond Facility8819 Whitepine RoadRichmond, Virginia 23237 USATel: +1 800 526 0555 (U.S. & Canada)

+1 804 714 2501Fax: +1 804 714 2507

Arlington Facility2312 Avenue JArlington, Texas 76006 USATel: +1 800 544 9729 (U.S. & Canada)

+1 817 640 7666Fax: +1 817 640 6644

Recife Facilityc/o Philips Medical Systems LtdaAv. Getúlio Vargas, 3560Distrito Industrial do CuradoEdf. D1 Térreo (parte) eEdf. D2 Térreo (parte)CEP50950-000 Recife, BrazilTel: +55 81 2122 7168Fax: +55 81 2122 7192

Dunlee Worldwide

Aurora, IL USA

Richmond, VA USA

Arlington, Texas USA

Recife, Brazil

Düsseldorf, Germany

Monza, Italy

Boutigny sur Essone, France

Beijing, China

Belgrade, Serbia

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 19

Page 20: Dunlee OEM Catalog

Contact Americas, Asia Pacific Region

DDuunnlleeee

555 North Commerce Street

Aurora, IL 60504, USA

Tel: +1 630 585 2100

Fax: +1 630 585 2125

www.dunlee.com

All rights are reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright holder.

Dunlee reserves the right to make changes in specifications and/or to discontinue any product at anytime without notice or obligation and will not be liable for any consequences resulting from the use ofthis publication. Dunlee is part of Philips Healthcare.

Printed in Germany: 4512 008 01201 * FEB 2008

Contact Europe, Middle East, Africa

DDuunnlleeee

Marbacher Straße 114

40597 Düsseldorf, Germany

Tel: +49 211 7705890

Fax: +49 211 203000

www.dunlee.com

p_Dunlee_Catalog 15.02.2008 9:30 Uhr Seite 20