PRODUCT RANGE
www.ducab.com
PRODUCT RANGE
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
• From 6 kV to 33 kV• Can provide Single Core / Three Core as required• Can provide lead sheathed cables• Can be watertight at conductor, Screen and / or armour level • Can provide steel tape armour for multicore cables • Available with LSZH sheath option• Available with PE (Poly Ethylene) sheath option• Available with copper screen in wires or conductors as required
• Manufacturing of XLPE insulated power cables from 60kV – 500kV
• Conductors in either copper or aluminium• Conductor sizes from 150mm2 – 2500mm2
• Cables are currently finished with a combination of either a lead sheath and copper wire screen or a laminated sheath and copper wire screen
Cu/XLPE/CTS/PVC/AWA/PVCCu/XLPE/CTS/LSZH/AWA/LSZH
MEDIUM VOLTAGE CABLES
HIGH VOLTAGE CABLES
Characteristics
Characteristics
Minimum service temperature -15˚ C
Minimum service temperature -15˚ C
Maximum service temperature 90˚ C
Maximum service temperature 90˚ C
Maximum short-circuit temperature 250˚ C (max. 5s)
Maximum short-circuit temperature 250˚ C (max. 5s)
Outdoor installation permanent
Flame non-propagation
Meter by meter marking
Meter by meter marking
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
WIRING CABLES Characteristics
Minimum service temperature -15˚ C
Service temperature 90˚ C can be offered for XL-LSZH and HR PVC
Maximum short-circuit temperature 160˚ C (max. 5s) for PVC & 250˚C for XL-LSZH
Flame non-propagation
Meter by meter marking
• Manufactured in sizes of 1.5upto 630 sq mm
• Rated 450/750V as per BS
• Upto 1 kV• Can provide lead sheathed cables • Available in armoured construction• Available with LSZH sheath option• Pilot cables as per customer design• Can provide XLPE insulated cables
suitable for 90˚C• Field bus cables are also available• Can provide fire rated cables as per
IEC 60331
Cu/PVCCu/XL-LSZH
Manufactured to higher temp. 105˚ CPVC upon request
105˚Service temperature 70˚ C for standard PVC
70˚
INSTRUMENTATION CABLESCharacteristics
Indoor installation permanent
Flame non-propagation
Cu/PVC/IS/OS/PVC/SWA/PVC
Service temperature 70˚ C70˚Minimum service
temperature -15˚ C
Maximum short-circuit temperature 160˚ C (max. 5s)
Service temperature 90˚ C can be offered
LOW VOLTAGE CABLESCharacteristics
Minimum service temperature -15˚ C
Maximum service temperature 90˚ C
Maximum short-circuit temperature 250˚ C (max. 5s)
Outdoor installation permanent
Flame non-propagationMeter by meter marking
• From 1 kV to 3.3 kV• Can provide Single Core / Multicore as required• Can provide lead sheathed cables• Can provide steel tape armour for multicore cables• Available with LSZH sheath option • Available with PE (Poly Ethylene) sheath option
Cu/XLPE/PVC/AWA/PVCCu/XLPE/LSZH/AWA/LSZH
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
FlamBICC 1 CABLES
FlamBICC 2a CABLES
Characteristics
Characteristics
Maximum service temperature 90˚ C
Maximum service temperature 90˚ C
Flame non-propagation
Flame non-propagation
Low corrosive gases emission
Low corrosive gases emission
Maximum short-circuit temperature 250˚ C (max. 5s)
Maximum short-circuit temperature 250˚ C (max. 5s)
Cu/MGT/XL-LSZH
Full range of fire performance cables from wiring cables to Power cables cab be provided
Cu/special insulation/ PolyAL/LSZH
1
• Certified to BS 6387 for small sizes• Certified to IEC 60331 for larger sizes
• Certified to BS 6387• Clas PH120 of BSEN 50200
LSZH
LSZH
2a
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
• Certified to BS 6387 for small sizes• Certified to IEC 60331 for larger sizes
FlamBICC 3 CABLES
FlamBICC 2a ENHANCED CABLES
FlamBICC 3 MULTICORE CABLES
3
2a
3
Characteristics
Characteristics
Maximum service temperature 90˚ C
Maximum service temperature 90˚ C
Flame non-propagation
Flame non-propagation
Low corrosive gases emission
Low corrosive gases emission
Maximum short-circuit temperature 160˚ C (max. 5s)
Maximum short-circuit temperature 160˚ C (max. 5s)
Cu/MGT/Thermosetting Insulation/LSZH
• BS 6387 CWZ and IEC 60331-21 at 950°C• Emergency lighting cable system
installations. Fire alarm systems.LSZH
LSZH
• Meets BS 7629- 1, BS 8434- 2 (120 minutes), BS 5839- 1 26.2 (e), Enhanced, BS EN 50200 PH120 and Annex E (30 min) voltage 300 / 500V
• Emergency lighting cable system installations. Fire detection and alarm systems. BS 5839-8 Voice Alarms, BS 5266- 1 8.2.2(b) Emergency lighting & BS 8519 Category 1, 2 & 3 control cable.
• Critical signal paths – addressable and networked systems
Maximum service temperature 90˚ C
Flame non-propagationLow corrosive gases emission
Maximum short-circuit temperature 250˚ C (max. 5s)
LSZH
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
• Power cables meeting BS 7846 F120, BS 8491 120 minutes and BS 6387 CWZ
• BS 8519 Category 1, 2 & 3 power and control applications
FlamBICC 6 POWER CABLES
FlamBICC 4 POWER CABLES
Characteristics
Characteristics
Maximum service temperature 90˚ C
Maximum service temperature 90˚ C
Flame non-propagation
Flame non-propagation
Low corrosive gases emission
Low corrosive gases emission
Maximum short-circuit temperature 250˚ C (max. 5s)
Maximum short-circuit temperature 160˚ C (max. 5s)
LSZH
LSZH
Cu/MGT/XLPE/LSZH/SWA/LSZH
Cu/MGT/XLPE/LSZH/SWA/LSZH
4
6
• Power cables meeting BS 7846 F2 & BS 6387 CWZ• ‘Enhanced’ BS 5839-1 26.2 (e) Fire Alarms, BS 5839-8
Voice Alarm, BS 5266-1 8.2.2(b) Emergency lighting• BS 8519 Category 1, 2 & 3 control cable
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
FLEXIBLE CABLES
ARCTIC GRADE
FLEXIBLE CABLES
Characteristics
Characteristics
Service temperature 90˚ / 105˚C can be offerd
Flame non-propagation
Flame non-propagation
Flexible conductor, class 5
Flexible conductor, class 5
Maximum short-circuit temperature 160˚ C (max. 5s)
Maximum short-circuit temperature 160˚ C (max. 5s)
Service temperature 70˚ C for standard
70˚C
Operating temperature 70˚ C
70˚Minimum service temperature -40˚ C
Cu/PVC/PVC
Cu/PVC/PVC
Minimum service temperature -15˚ C
• Lowest ambient temprature for operation -40˚C for Artic Grade cables
105˚
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
THHN / THWN CABLESCharacteristics
Minimum service temperature -15˚ C
Maximum short-circuit temperature 160˚ C (max. 5s)
Oil resistantCu/PVC/Nylon
RUBBER FLEXIBLE CABLES
Characteristics
Flexible conductor, class 5/6
Flexible conductor
90˚ C in dry & 75˚ C in wet location
75 /̊90˚
• As per UL standard
Maximum short-circuit temperature 250˚ C (max. 5s)
Minimum service temperature -40˚ C
Service Temperature 90˚ C
• Available for different hormonized grades (H07RN-F, H07BN4-F, H05BN4-F, etc..,). Arc welding cables
Dupan PANEL WIRE
Characteristics
Minimum service temperature -15˚ C
Service temperature shall be 90˚ C90˚
• BS 6231, Type CK• Circular class 5 flexible copper conductor as per BS EN 60228• Heat Resistant PVC type TI3 as per BS EN 50363-3• 600/1000 V• BS EN / IEC 60332-1• -15°C to 90°C operating temperature
DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE
PetroBICC CABLES
NuBICC CABLES
Characteristics
Characteristics
Minimum service temperature -15˚ C
Minimum service temperature -15˚ C
Maximum short-circuit temperature 250˚ C (max. 5s)
Oil / Hydrocarbon resistant
Service temperature shall be 90˚ C90˚
For oil, gas and petro chemical industrires
Special cables for nuclear power plants
Maximum short-circuit temperature 250˚ C (max. 5s)
Service Temperature 90˚ C for cables with XLPE insulation
• Available in LV/MV Power, LV control / auxiliary and instrumentation cables
Poly-Amide sheathed cable
• Tinned copper/ XLPE or EPR / XL-LSZH or Rubber sheath
• 1kV to 15kV• As per NEMA standard• Available in 1C or Triplex construction
MarineBICC CABLES
Characteristics
Minimum service temperature -15˚ C
For ship wiring applications
LSZHMaximum short-circuit temperature 250˚ C (max. 5s)
Service Temperature 90˚ C
• As per IEC 60092 standard• Available for power, control,
instrumentation & ship board applications
Jebel Ali FactoryPO Box: 11529, Jebel Ali, Dubai, UAE.Tel: +971 4 815 8888, Fax: +971 4 815 8111Email: [email protected]
Ducab Mussafah 1 FactoryPO Box: 9171, Abu Dhabi, UAE.Tel: +971 2 502 7777, Fax: +971 2 502 7755Email: [email protected]
Ducab Mussafah 2 FactoryPO Box: 9171, Abu Dhabi, UAE.Tel: +971 2 550 0774, Fax: +971 2 550 0979Email: [email protected]
Ducab - HVPO Box: 683, Dubai, UAE.Tel: +971 4 815 8600, Fax: +971 4 815 8666Email: [email protected]
Dubai Cable Co (P) Ltd.( Ducab) - KSA403, Al-Za’abi TowerPrince Mohammad Bin Fahad Road, 1st StreetPO Box: 60662, Dammam-31555, KSATel: +966 3 835 5305, Fax: +966 3 835 5307Mob: +966 50 825 5581Email: [email protected]
Ducab - OmanPO Box: 3542,112 RUWI,MuscatTel: +968 24565178, Fax: +968 24564302Email: [email protected]
Ducab - AustraliaLevel 3, Suite 4, 695 Burke Road, Camberwell, 3124, Victoria, AustraliaTel: +61 413 658 856Email: [email protected]
Ducab Joint Venture – BahrainBICC MET W.L.L.PO Box: 11413, ManamaTel: +973 177 497 61Fax: +973 177 425 88Email: [email protected]
Ducab Joint Venture – QatarJBK DUCAB W.L.L (JV) PO Box: 14039, Office No. C103, Block 18, SAFWA Building, DohaTel: +974 4005 3000Fax: +974 4006 1201Email: [email protected]
AEI Cables Ltd. (Ducab Cable Group Co.)PO Box: Durham DH3 2RA, Durham RoadBirtley, Chester-le-Street, Co. DurhamTel: +44 191 410 3111Fax: +44 191 410 8312Email: [email protected]@aeicables.co.uk