Ducab product range catalogue

10
PRODUCT RANGE www.ducab.com PRODUCT RANGE

description

 

Transcript of Ducab product range catalogue

Page 1: Ducab product range catalogue

PRODUCT RANGE

www.ducab.com

PRODUCT RANGE

Page 2: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

• From 6 kV to 33 kV• Can provide Single Core / Three Core as required• Can provide lead sheathed cables• Can be watertight at conductor, Screen and / or armour level • Can provide steel tape armour for multicore cables • Available with LSZH sheath option• Available with PE (Poly Ethylene) sheath option• Available with copper screen in wires or conductors as required

• Manufacturing of XLPE insulated power cables from 60kV – 500kV

• Conductors in either copper or aluminium• Conductor sizes from 150mm2 – 2500mm2

• Cables are currently finished with a combination of either a lead sheath and copper wire screen or a laminated sheath and copper wire screen

Cu/XLPE/CTS/PVC/AWA/PVCCu/XLPE/CTS/LSZH/AWA/LSZH

MEDIUM VOLTAGE CABLES

HIGH VOLTAGE CABLES

Characteristics

Characteristics

Minimum service temperature -15˚ C

Minimum service temperature -15˚ C

Maximum service temperature 90˚ C

Maximum service temperature 90˚ C

Maximum short-circuit temperature 250˚ C (max. 5s)

Maximum short-circuit temperature 250˚ C (max. 5s)

Outdoor installation permanent

Flame non-propagation

Meter by meter marking

Meter by meter marking

Page 3: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

WIRING CABLES Characteristics

Minimum service temperature -15˚ C

Service temperature 90˚ C can be offered for XL-LSZH and HR PVC

Maximum short-circuit temperature 160˚ C (max. 5s) for PVC & 250˚C for XL-LSZH

Flame non-propagation

Meter by meter marking

• Manufactured in sizes of 1.5upto 630 sq mm

• Rated 450/750V as per BS

• Upto 1 kV• Can provide lead sheathed cables • Available in armoured construction• Available with LSZH sheath option• Pilot cables as per customer design• Can provide XLPE insulated cables

suitable for 90˚C• Field bus cables are also available• Can provide fire rated cables as per

IEC 60331

Cu/PVCCu/XL-LSZH

Manufactured to higher temp. 105˚ CPVC upon request

105˚Service temperature 70˚ C for standard PVC

70˚

INSTRUMENTATION CABLESCharacteristics

Indoor installation permanent

Flame non-propagation

Cu/PVC/IS/OS/PVC/SWA/PVC

Service temperature 70˚ C70˚Minimum service

temperature -15˚ C

Maximum short-circuit temperature 160˚ C (max. 5s)

Service temperature 90˚ C can be offered

LOW VOLTAGE CABLESCharacteristics

Minimum service temperature -15˚ C

Maximum service temperature 90˚ C

Maximum short-circuit temperature 250˚ C (max. 5s)

Outdoor installation permanent

Flame non-propagationMeter by meter marking

• From 1 kV to 3.3 kV• Can provide Single Core / Multicore as required• Can provide lead sheathed cables• Can provide steel tape armour for multicore cables• Available with LSZH sheath option • Available with PE (Poly Ethylene) sheath option

Cu/XLPE/PVC/AWA/PVCCu/XLPE/LSZH/AWA/LSZH

Page 4: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

FlamBICC 1 CABLES

FlamBICC 2a CABLES

Characteristics

Characteristics

Maximum service temperature 90˚ C

Maximum service temperature 90˚ C

Flame non-propagation

Flame non-propagation

Low corrosive gases emission

Low corrosive gases emission

Maximum short-circuit temperature 250˚ C (max. 5s)

Maximum short-circuit temperature 250˚ C (max. 5s)

Cu/MGT/XL-LSZH

Full range of fire performance cables from wiring cables to Power cables cab be provided

Cu/special insulation/ PolyAL/LSZH

1

• Certified to BS 6387 for small sizes• Certified to IEC 60331 for larger sizes

• Certified to BS 6387• Clas PH120 of BSEN 50200

LSZH

LSZH

2a

Page 5: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

• Certified to BS 6387 for small sizes• Certified to IEC 60331 for larger sizes

FlamBICC 3 CABLES

FlamBICC 2a ENHANCED CABLES

FlamBICC 3 MULTICORE CABLES

3

2a

3

Characteristics

Characteristics

Maximum service temperature 90˚ C

Maximum service temperature 90˚ C

Flame non-propagation

Flame non-propagation

Low corrosive gases emission

Low corrosive gases emission

Maximum short-circuit temperature 160˚ C (max. 5s)

Maximum short-circuit temperature 160˚ C (max. 5s)

Cu/MGT/Thermosetting Insulation/LSZH

• BS 6387 CWZ and IEC 60331-21 at 950°C• Emergency lighting cable system

installations. Fire alarm systems.LSZH

LSZH

• Meets BS 7629- 1, BS 8434- 2 (120 minutes), BS 5839- 1 26.2 (e), Enhanced, BS EN 50200 PH120 and Annex E (30 min) voltage 300 / 500V

• Emergency lighting cable system installations. Fire detection and alarm systems. BS 5839-8 Voice Alarms, BS 5266- 1 8.2.2(b) Emergency lighting & BS 8519 Category 1, 2 & 3 control cable.

• Critical signal paths – addressable and networked systems

Maximum service temperature 90˚ C

Flame non-propagationLow corrosive gases emission

Maximum short-circuit temperature 250˚ C (max. 5s)

LSZH

Page 6: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

• Power cables meeting BS 7846 F120, BS 8491 120 minutes and BS 6387 CWZ

• BS 8519 Category 1, 2 & 3 power and control applications

FlamBICC 6 POWER CABLES

FlamBICC 4 POWER CABLES

Characteristics

Characteristics

Maximum service temperature 90˚ C

Maximum service temperature 90˚ C

Flame non-propagation

Flame non-propagation

Low corrosive gases emission

Low corrosive gases emission

Maximum short-circuit temperature 250˚ C (max. 5s)

Maximum short-circuit temperature 160˚ C (max. 5s)

LSZH

LSZH

Cu/MGT/XLPE/LSZH/SWA/LSZH

Cu/MGT/XLPE/LSZH/SWA/LSZH

4

6

• Power cables meeting BS 7846 F2 & BS 6387 CWZ• ‘Enhanced’ BS 5839-1 26.2 (e) Fire Alarms, BS 5839-8

Voice Alarm, BS 5266-1 8.2.2(b) Emergency lighting• BS 8519 Category 1, 2 & 3 control cable

Page 7: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

FLEXIBLE CABLES

ARCTIC GRADE

FLEXIBLE CABLES

Characteristics

Characteristics

Service temperature 90˚ / 105˚C can be offerd

Flame non-propagation

Flame non-propagation

Flexible conductor, class 5

Flexible conductor, class 5

Maximum short-circuit temperature 160˚ C (max. 5s)

Maximum short-circuit temperature 160˚ C (max. 5s)

Service temperature 70˚ C for standard

70˚C

Operating temperature 70˚ C

70˚Minimum service temperature -40˚ C

Cu/PVC/PVC

Cu/PVC/PVC

Minimum service temperature -15˚ C

• Lowest ambient temprature for operation -40˚C for Artic Grade cables

105˚

Page 8: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

THHN / THWN CABLESCharacteristics

Minimum service temperature -15˚ C

Maximum short-circuit temperature 160˚ C (max. 5s)

Oil resistantCu/PVC/Nylon

RUBBER FLEXIBLE CABLES

Characteristics

Flexible conductor, class 5/6

Flexible conductor

90˚ C in dry & 75˚ C in wet location

75 /̊90˚

• As per UL standard

Maximum short-circuit temperature 250˚ C (max. 5s)

Minimum service temperature -40˚ C

Service Temperature 90˚ C

• Available for different hormonized grades (H07RN-F, H07BN4-F, H05BN4-F, etc..,). Arc welding cables

Dupan PANEL WIRE

Characteristics

Minimum service temperature -15˚ C

Service temperature shall be 90˚ C90˚

• BS 6231, Type CK• Circular class 5 flexible copper conductor as per BS EN 60228• Heat Resistant PVC type TI3 as per BS EN 50363-3• 600/1000 V• BS EN / IEC 60332-1• -15°C to 90°C operating temperature

Page 9: Ducab product range catalogue

DUCAB PRODUCT RANGEDUCAB PRODUCT RANGE

PetroBICC CABLES

NuBICC CABLES

Characteristics

Characteristics

Minimum service temperature -15˚ C

Minimum service temperature -15˚ C

Maximum short-circuit temperature 250˚ C (max. 5s)

Oil / Hydrocarbon resistant

Service temperature shall be 90˚ C90˚

For oil, gas and petro chemical industrires

Special cables for nuclear power plants

Maximum short-circuit temperature 250˚ C (max. 5s)

Service Temperature 90˚ C for cables with XLPE insulation

• Available in LV/MV Power, LV control / auxiliary and instrumentation cables

Poly-Amide sheathed cable

• Tinned copper/ XLPE or EPR / XL-LSZH or Rubber sheath

• 1kV to 15kV• As per NEMA standard• Available in 1C or Triplex construction

MarineBICC CABLES

Characteristics

Minimum service temperature -15˚ C

For ship wiring applications

LSZHMaximum short-circuit temperature 250˚ C (max. 5s)

Service Temperature 90˚ C

• As per IEC 60092 standard• Available for power, control,

instrumentation & ship board applications

Page 10: Ducab product range catalogue

Jebel Ali FactoryPO Box: 11529, Jebel Ali, Dubai, UAE.Tel: +971 4 815 8888, Fax: +971 4 815 8111Email: [email protected]

Ducab Mussafah 1 FactoryPO Box: 9171, Abu Dhabi, UAE.Tel: +971 2 502 7777, Fax: +971 2 502 7755Email: [email protected]

Ducab Mussafah 2 FactoryPO Box: 9171, Abu Dhabi, UAE.Tel: +971 2 550 0774, Fax: +971 2 550 0979Email: [email protected]

Ducab - HVPO Box: 683, Dubai, UAE.Tel: +971 4 815 8600, Fax: +971 4 815 8666Email: [email protected]

Dubai Cable Co (P) Ltd.( Ducab) - KSA403, Al-Za’abi TowerPrince Mohammad Bin Fahad Road, 1st StreetPO Box: 60662, Dammam-31555, KSATel: +966 3 835 5305, Fax: +966 3 835 5307Mob: +966 50 825 5581Email: [email protected]

Ducab - OmanPO Box: 3542,112 RUWI,MuscatTel: +968 24565178, Fax: +968 24564302Email: [email protected]

Ducab - AustraliaLevel 3, Suite 4, 695 Burke Road, Camberwell, 3124, Victoria, AustraliaTel: +61 413 658 856Email: [email protected]

Ducab Joint Venture – BahrainBICC MET W.L.L.PO Box: 11413, ManamaTel: +973 177 497 61Fax: +973 177 425 88Email: [email protected]

Ducab Joint Venture – QatarJBK DUCAB W.L.L (JV) PO Box: 14039, Office No. C103, Block 18, SAFWA Building, DohaTel: +974 4005 3000Fax: +974 4006 1201Email: [email protected]

AEI Cables Ltd. (Ducab Cable Group Co.)PO Box: Durham DH3 2RA, Durham RoadBirtley, Chester-le-Street, Co. DurhamTel: +44 191 410 3111Fax: +44 191 410 8312Email: [email protected]@aeicables.co.uk