Dual-Homing Protection for MPLS and MPLS-TP Pseudowires
Weiqiang Cheng, L. Wang, H. Li (China Mobile)K. Liu, J. Dong (Huawei)
S. Davari (Broadcom)A. D'Alessandro (Telecom Italia)
IETF91 PALS Honolulu 2014
Background
• Work was presented in IETF 88 and 90
• Split the draft according to PWE3 chairs’ suggestion:
– Framework and scenarios of dual-homing PW protection
– Protocol extensions for dual-homing protection with static
MPLS-TP PWs
Benefits of Dual-homing Protection
• Local protection– Avoid PW switchover due to AC failure – Avoid AC switchover due to PW failure
• PSN tunnel protection is no longer a MUST
PE Architecture Update
• DNI PW between dual-homing PEs can carry traffic during failure
• Forwarder is responsible for switching traffic between AC,
service PW and DNI PW.
Dual-homing PE Device
Forwarder
DNI PWService PW
Peer Dual-homing PE Device
AC
DNI PW
Service PW
• Can Provide protection for:– AC failure– PE failure– PSN network failure
PE3
PE1
PE2
CE2CE1DNI
PW
linear protection
Working PW
Protection PW
linear protection
AC RedundancyMechanism
dual-homing coordination
Service PW
Service PW
AC1
AC2
One-side Dual-homing Scenario
One-side Dual-homing Scenario
• Can Provide protection for:– AC failure– PSN network failure– PE failure
PE3
PE1
PE2
CE2CE1
1DNIPW
linear protection
Working PW
Protection PW
linear protection
AC RedundancyMechanism
dual-homing coordination
AC1
AC2
One-side Dual-homing Scenario
• Can Provide protection for:– AC failure– PSN network failure– PE failure
PE3
PE1
PE2
CE2CE1
2DNIPW
linear protection
Working PW
Protection PW
linear protection
AC RedundancyMechanism
dual-homing coordination
AC1
AC2
One-side Dual-homing Scenario
• Can Provide protection for:– AC failure– PSN network failure– PE failure
PE3
PE1
PE2
CE2CE1
3
DNIPW
linear protection
Working PW
Protection PW
linear protection
AC RedundancyMechanism
dual-homing coordination
AC1
AC2
Two-side Dual-homing Scenario
• Can Provide protection for:– AC failure– PE failure– PSN network failure
PE3 PE2
CE2 CE1DNIPW
linear protection
Working PW
Protection PW
AC RedundancyMechanism
AC1
AC2
PE3 PE1
linear protection
DNIPW
AC redundancymechanism
43
1
2
5
General Procedures• Dual-homing PEs need to exchange PW state and
switchover coordination request to synchronize the protection switching
• Forwarding behavior of dual-homing PE is determined by:– Status of Service PW– Status of AC– Status of DNI PW
Service PW AC DNI PW Forwarding BehaviorActive Active Up Service PW <-> AC
Active Standby Up Service PW <-> DNI PW
Standby Active Up DNI PW <-> AC
Standby Standby Up Drop all packets
ACService PW
DNI PW
Next Steps
• Solicit comments from WG
• WG adoption?