NON-ELECTRICAL EQUIPMENT GUIDANCE FOR MANUFACTURERS AND END USERS Gas Groups  Gas Representative  Group Test Gas  I Methane  (mining only)  IIA Propane  IIB Ethylene  IIC Hydrogen Gases are classified according to the ignitability of gas-air mixture. Refer to IEC/EN 60079-20-1 for classification of common gases and vapours. Temperature Class  T Class Maximum Surface  Temperature  T1 450°C  T2 300°C  T3 200°C  T4 135°C  T5 100°C  T6 85°C Standards EN13463-1 EN13463-2 EN13463-3 EN13463-5 EN13463-6 EN13463-8 Concept general requirements flow restriction flameproof constructional safety control of ignition sources liquid immersion Code fr d c b k Zone 2 22 1 21 1 21 1 21 1 21 SGS Baseefa Limited, Rockhead Business Park, Staden Lane, Buxton, SK17 9RZ tel. +44 (0)12 98 766600 fax. +44 (0)1298 766601 e-mail [email protected]  ATEX Cod ing  II 2 GD EU Explosive atmosphere symbol Equipment group I - mining II - non-mining (*) = in presence of explosive atmosphere Equipment category M1 - energised M2 - de-energised (*) 1 - very high  protection 2 - high protection 3 - normal protection  Gas Dust  0 20  1 21  2 22 Ingress Protection (IP) Hazardous area equipment typically requires a minimum IP rating of IP54 but may be assessed and tested to the higher ratings below:  DUST  IP 5x - Dust protected  IP 6x - Dust tight  WATER  Protected against:  IP x4 - splashing water  IP x5 - water jets  IP x6 - powered water jets  IP x7 - temporary immersion  IP x8 - continuous immersion See IEC/EN 60529 for full definition of IP ratings Mechanical Protection Concepts EX Manufacturer’s Name and Address Product Identification Serial No. and (or inc.) Year of Manufacture ATEX Notified Body Identification No. (Zone 0/20 only)  II 1GD IIC T4 ck Baseefa10ATEX1111X Gas Group Protection Concept Temperature Class ATEX Coding ATEX Certificate No. (or Manufacturer’s Technical File No.) Ambient Range 1180 Tamb -30ºC to +50ºC  ABC Engineering Buxton, SK17 9RZ, UK Type xyz Pump 2009 s/n 1234 Pub DS51 Issue 5, August 2013 Ignition Risk Assessment rare malfunction N/A N/A * expected malfunction N/A * ** normal operation * * ** Category 3 – Zone 2/22 Category 2 – Zone 1/21 Category 1 – Zone 0/20 * Describe the single measure applied to pr event the ignition source from becoming effective. Where appropriat e refer to standards used and test reports which substantiate compliance with the standards ** Describe two independent measu res used to prevent ignition source from becoming effective. Again refer to relevant standards and test reports. N/A – Need not be considered for this zone Identify all potential ignition sources (see table below) Which apply to your product? Do they occur during:  GAS  Explosion Non-sparking Other materials  Group metals (*)  IIC 60 5 (hydrogen)  3 (hydrocarbons  Category 1G including acetylene)  IIB 125 10  IIA 125 20  IIC 125 10  Category 2G IIB 250 20  IIA 500 40  IIC 250 20  Category 3G IIB 500 40 IIA 500 80  DUST  Category 1D 125 20  Category 2D 500 80  Category 3D (*) excluding materials specified in cl. 6.4.2.1 a) of EN13463-1: 2009 Single Impact Energy Limits (Nm) Technical file contents General description Ignition risk assessment Design and manufacturing drawings Description and explanation necessary to understand operation of product List of standards or other solutions to meet EHSRs Calculations and examinations Test Results Possible Ignition Sources (list from EN 1127-1) Hot surfaces Mechanical sparks Flames, hot gases Electric sparks Stray electric currents and Cathodic protection Static electricity Lightning Electromagnetic waves Ionising radiation High frequency radiation Ultrasonics Adiabatic compression Chemical reaction Minimum ATEX requirements for non-electrical products Category 1–Zone 0/20 N.B. certification and QA assessment Category 2–Zone 1/21 Manufacturer’s technical file lodged with N.B. Category 3–Zone 2/22 Manufacturer stores own t echnical file N.B. = Notified Body  A TEX  ATEX and IECEx certification IECEx Certificate of Personnel Competance IEC 61508 certification Quality system approval  Assistance w ith DSEAR (A TEX User Directive) Impl ementation Training & Technical Advice IECEx Service Facility Certification Technical file storage Testing Baseefa Services www.baseefa.com

description

Ex Non Electrical Wall Chart

Transcript of DS51 Non Electrical Wallchart Iss5 0813

  • NON-ELECTRICAL EQUIPMENTGUIDANCE FOR MANUFACTURERS AND END USERS

    Gas Groups Gas Representative Group Test Gas I Methane (mining only) IIA Propane IIB Ethylene IIC Hydrogen

    Gases are classified according to theignitability of gas-air mixture.Refer to IEC/EN 60079-20-1 for classificationof common gases and vapours.

    Temperature Class T Class Maximum Surface Temperature T1 450C T2 300C T3 200C T4 135C T5 100C T6 85C

    Standards

    EN13463-1

    EN13463-2

    EN13463-3

    EN13463-5

    EN13463-6

    EN13463-8

    Conceptgeneral

    requirements

    flow restriction

    flameproofconstructional

    safetycontrol ofignitionsources

    liquidimmersion

    Code

    fr

    d

    c

    b

    k

    Zone

    2221

    211

    211

    21

    121

    SGS Baseefa Limited,Rockhead Business Park,Staden Lane,Buxton, SK17 9RZtel. +44 (0)1298 766600fax. +44 (0)1298 766601e-mail [email protected]

    ATEX Coding II 2 GD

    EUExplosiveatmospheresymbol

    Equipmentgroup

    I - mining

    II - non-mining

    (*) = in presence of explosive atmosphere

    EquipmentcategoryM1 - energisedM2 - de-energised (*)

    1 - very high protection2 - high protection3 - normal protection

    Gas Dust 0 20

    1 21 2 22

    Ingress Protection (IP)Hazardous area equipment typically requiresa minimum IP rating of IP54 but may beassessed and tested to the higher ratings below: DUST IP 5x - Dust protected IP 6x - Dust tight WATER Protected against: IP x4 - splashing water IP x5 - water jets IP x6 - powered water jets IP x7 - temporary immersion IP x8 - continuous immersionSee IEC/EN 60529 for full definition ofIP ratings

    Mechanical Protection Concepts

    EX

    Manufacturers Nameand Address

    Product Identification

    Serial No. and (or inc.)Year of Manufacture

    ATEX Notified BodyIdentification No.(Zone 0/20 only)

    II 1GD IIC T4 ck

    Baseefa10ATEX1111X

    Gas GroupProtection ConceptTemperature Class

    ATEX Coding

    ATEX Certificate No.(or ManufacturersTechnical File No.)

    Ambient Range1180

    Tamb -30C to +50C

    ABC EngineeringBuxton, SK17 9RZ, UK

    Type xyz Pump2009 s/n 1234

    Pub DS51 Issue 5, August 2013

    Ignition Risk Assessment

    raremalfunction

    N/AN/A

    *

    expectedmalfunction

    N/A

    *

    **

    normaloperation

    *

    *

    **

    Category 3 Zone 2/22Category 2 Zone 1/21Category 1 Zone 0/20

    * Describe the single measure applied to prevent the ignition source from becoming effective. Where appropriate refer to standards used and test reports which substantiate compliance with the standards

    ** Describe two independent measures used to prevent ignition source from becoming effective. Again refer to relevant standards and test reports.

    N/A Need not be considered for this zone

    Identify all potentialignition sources(see table below)

    Which applyto your

    product?Do they occur

    during:

    GAS Explosion Non-sparking Other materials Group metals (*) IIC 60 5 (hydrogen) 3 (hydrocarbons Category 1G including acetylene) IIB 125 10 IIA 125 20

    IIC 125 10 Category 2G IIB 250 20 IIA 500 40

    IIC 250 20 Category 3G IIB 500 40 IIA 500 80 DUST Category 1D 125 20 Category 2D 500 80 Category 3D (*) excluding materials specified in cl. 6.4.2.1 a) of EN13463-1: 2009

    Single Impact Energy Limits (Nm)

    Technical filecontents

    General descriptionIgnition risk assessmentDesign and manufacturing drawingsDescription and explanation necessary to understand operation of productList of standards or other solutions to meet EHSRsCalculations and examinationsTest Results

    Possible IgnitionSources

    (list from EN 1127-1)Hot surfacesMechanical sparksFlames, hot gasesElectric sparksStray electric currents and Cathodic protectionStatic electricityLightningElectromagnetic wavesIonising radiationHigh frequency radiationUltrasonicsAdiabatic compressionChemical reaction

    Minimum ATEX requirementsfor non-electrical products

    Category 1Zone 0/20 N.B. certification and QA assessment

    Category 2Zone 1/21 Manufacturers technical file lodged with N.B.

    Category 3Zone 2/22 Manufacturer stores own technical file

    N.B. = Notified Body