Components and Ancillary Items Torque-Lock ® Small Diameter Implants demand initial stability and adequate insertion torque to ensure lasting success. Torque-Lock ® Ratchet Wrench eliminates any guesswork. It can accurately determine torque forces from 10 to 50 Ncm. Torque-Lock ® utilizes a patented technology of rubies and sapphires as bearing surfaces that provide minimal friction on the return stroke. They also resist the accumulation of blood and saliva and guarantee precision. Mini Drive-Lock Surgical Box Accommodates all MDL ® surgical instruments for MDL ® Implant delivery and placement. Also accommodates MILO ® Instrumentation. • Laser etched Stainless Steel insert Patient Education Model Denture and Crown & Bridge models are excellent for patient education and marketing. Implant Insertion Instruments Drive-Lock ® Technology Package-to-Site, Direct Delivery Contra-Angle or Ratchet Driver Ergonomic Design Mini Dental Implants Please contact us with any enquiries or visit our website for more information (03) 9893 2399 or [email protected] www.idhealth.net Intra-Lock® , MDL®, MILO® and Ossean® are registered trademarks of Intra-Lock International, Inc.

Transcript of Drills, Implant Insertion Instruments · 2018-05-03 · Denture and Crown & Bridge models are...

Page 1: Drills, Implant Insertion Instruments · 2018-05-03 · Denture and Crown & Bridge models are excellent for patient education and marketing. Implant Insertion Instruments Drive-Lock®

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Components and Ancillary Items

Torque-Lock®

Small Diameter Implants demand initial stability and adequate insertion torque to ensure lasting success. Torque-Lock® Ratchet Wrench eliminates any guesswork. It can accurately determine torque forces from 10 to 50 Ncm. Torque-Lock® utilizes a patented technology of rubies and sapphires as bearing surfaces that provide minimal friction on the return stroke. They also resist the accumulation of blood and saliva and guarantee precision.

Mini Drive-Lock Surgical Box

Accommodates all MDL® surgical instruments

for MDL® Implant delivery and placement.

Also accommodates MILO® Instrumentation.

• Laser etched Stainless Steel insert

• Mandibular denture model excellent for patient education

and marketing.

• Four implants, O-Rings and housing.

Ref No.

TL

Ref No.

MLSK

Ref No.

MDLMOD

Mini Drive-Lock Surgical Box

MDL® Patient Education Model

Torque-Lock ®

Small Diameter Implants demand initial stability and adequate insertion torque to ensure lasting success. Torque-Lock® Ratchet

Wrench eliminates any guesswork. It can accurately determine torque forces from 10 to 50 Ncm. Torque-Lock® utilizes a

patented technology of rubies and sapphires as bearing surfaces that provide minimal friction on the return stroke. They also

resist the accumulation of blood and saliva and guarantees extremely consistent precision.

Components and Ancillary Items

Accommodates all MDL® surgical instruments for MDL® Implant delivery and placement. Also accommodates MILO® Instrumentation.

• Laser etched Stainless Steel insert

Patient Education Model

Accommodates all MDL® surgical instruments

for MDL® Implant delivery and placement.

Also accommodates MILO® Instrumentation.

• Laser etched Stainless Steel insert

• Mandibular denture model excellent for patient education

and marketing.

• Four implants, O-Rings and housing.

Ref No.

TL

Ref No.

MLSK

Ref No.

MDLMOD

Mini Drive-Lock Surgical Box

MDL® Patient Education Model

Torque-Lock ®

Small Diameter Implants demand initial stability and adequate insertion torque to ensure lasting success. Torque-Lock® Ratchet

Wrench eliminates any guesswork. It can accurately determine torque forces from 10 to 50 Ncm. Torque-Lock® utilizes a

patented technology of rubies and sapphires as bearing surfaces that provide minimal friction on the return stroke. They also

resist the accumulation of blood and saliva and guarantees extremely consistent precision.

Components and Ancillary Items

Denture and Crown & Bridge models are excellent for patient education and marketing.

Implant Insertion Instruments

Drive-Lock® Technology• Package-to-Site, Direct Delivery• Contra-Angle or Ratchet Driver• Ergonomic Design

Mini Dental Implants

Please contact us with any enquiries or visit our website for more information

(03) 9893 2399 or [email protected] www.idhealth.net

Intra-Lock® , MDL®, MILO® and Ossean® are registered trademarks of Intra-Lock International, Inc.

Page 2: Drills, Implant Insertion Instruments · 2018-05-03 · Denture and Crown & Bridge models are excellent for patient education and marketing. Implant Insertion Instruments Drive-Lock®

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Mini Drive-Lock™ Ratchet Driver ... MDLRD

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Mini Drive-Lock™ Ratchet Driver, Long ... MDLRDL

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Mini Drive-Lock™ Wrench connects to the Mini Drive-Lock

Ratchet Driver ... MDLMW

One-Piece Implant. Multiple Applications

Mini Drive-Lock (MDL®) is Intra-Lock’s one-piece small diameter dental implant. The system is ideal for long-term denture stabilization or fixed prosthetics. MDL® is a true ‘convertible’ implant with one-piece solid strength and two-piece versatility. Patented Cement-Over™ Abutments, simply fit over the O-Ball Assembly and convert the implant from removable to fixed treatment options.

The system’s unique Drive-Lock™ instruments reduce delivery and placement to one fluid motion. Once in place, Intra-Lock’s extremely hydrophilic, bio-active OSSEAN® Surface promotes rapid early healing and increased biomechanical fixation1.

2.0 + 2.5mm

One-Piece Strength. Two-Piece Versatility

The MILO® Implant System is engineered for the anatomical and physiological demands of long-term denture stabilization or the permanent rehabilitation of single or multiple incisors. The simplified surgical protocol is similar to that of a miniature implant, however, MILO®

has the added advantages of increased bone surface interface, improved load transfer capabilities and greater yield strength.

MILO® is a true convertible implant with one-piece solid strength and two-piece versatility. The Cement-Over Abutments™ provide the clinician with an extensive range of prosthetic options.

MDL2513MDL2513L MDL2013

Leng

th

Act

ive

Leng

th

Mini Drive-Lock (MDL®) is Intra-Lock’s

one-piece small diameter dental implant.

The system is ideal for long-term denture stabilization

or fixed prosthetics. MDL® is a true 'convertible'

implant with one-piece solid strength and two-piece

versatility. Patented* Cement-Over™ Abutments, simply fit

over the O-Ball Assembly and convert the implant from

removable to fixed or orthodontic treatment options. The

system’s unique Drive-Lock™ instruments reduce delivery and

placement to one fluid motion. Once in place, Intra-Lock’s

extremely hydrophilic, bio-active OSSEAN® Surface promotes

rapid early healing and increased biomechanical fixation1.

All implants are packaged with the Micro Metal Housing with O-Ring.

MDL® Mini Drive-Lock Implants, 2.0mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2010 MDL2011 MDL2013 MDL2015 MDL2018

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510 MDL2511 MDL2513 MDL2515 MDL2518

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, Long Collar, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510L MDL2511L MDL2513L MDL2515L MDL2518L

MDL® Mini Drive-Lock Implant, 2.0mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2013P

MDL® Mini Drive-Lock Implant, 2.5mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2513P

*The actual thread length is 2mm less than the catalog description, regardless of the height of the collar (2mm or 4mm).

Mini Drive-Lock Implants One Implant... Multiple Applications.

• “Long-Term”Applications

• OSSEAN ® SurfaceApplied to Collarand Body

• Cement -Over ™

Abutments

• DirectDelivery

OSSEAN® Surface is characterized by its fractal2 topography that extends beyond thenanoscale level. OSSEAN® has an extremely hydrophilic surface and is impregnatedwith Calcium Phosphate molecules that are incorporated into the surface structure atthe molecular level. Due to this molecular impregnation, binding forces make theCalcium Phosphate exceptionally stable while preserving its bioactive properties.

• “Long Term” Applications• OSSEAN® Surface Applied to

Collar and Body• Cement-Over™ Abutments• Direct Delivery

The MILO™ Implant System is engineered for the anatomical andphysiological demands of long-term denture stabilization or thepermanent rehabilitation of single or multiple incisors. The simplifiedsurgical protocol is similar to that of a miniature implant, however,MILO™ has the added advantages of increased bone surface interface,improved load transfer capabilities and greater yield strength.

MILO™ Implants* are available in five lengths (10, 11.5, 13, 15 and17 mm) and two thread profiles (Fine Pitch and Wide Pitch) thatare engineered to address the clinical quality and quantity of bone.

MILO™ is a true convertible implantwith one-piece solid strength andtwo-piece versatility. The Cement-OverAbutments™** provide the clinicianwith an unsurpassed range ofprosthetic options.

IMPLANT INSERTION INSTRUMENTS

MDLCAD

MDLMW

MDLRD

MILO Contra Angle Driver• Standard Contra Angle .................................................................... MDLCAD

MILO™ Ratchet Drivers

Use as a MILO™ Hand Driver or with a Surgical Ratchet Wrench• Surgical Ratchet Driver ...................................................................... MDLRD• Surgical Ratchet Driver, Long............................................................ MDLRDL

MILO™ Manual Wrench• Connects to the Ratchet Driver ........................................................ MDLMW

Tissue Punch• Latch Tissue Punch ø3mm .................................................................... RPCA3

Surgical Ratchet Wrench• With standard 4x4mm connection, autoclavable ...................................... SRA

Surgical Box• Accommodates all MILO surgical instruments for Implant delivery and placement.

Laser etched Stainless steel insert .......................................................... MLSK

DRILLS• Lancer 0-2mm - Sterile .............................................................................. LD• Pilot Drill ø1.5mm Sterile ........................................................................ D15• Twist Drill ø2.0mm Sterile ........................................................................ D20• Final Drill ø2.5mm - Sterile ...................................................................... D25

MDLRDL

LD

D15

D20

D25

A N D A N C I L L A R Y I T E M S

RPCA3

SRA

ONE-PIECE IMPLANT. MULTIPLE APPLICATIONS.

3

* Pat. #7,033,174** Pat. #7,217,130

MILO™ can be usedwith an O-Ring

and Metal Housingor an abutment

StandardAbutment

DentureStabilization

WideAbutment

AngledAbutment

Denture Stabilization

Standard Abutment

AngledAbutment

WideAbutment

MILO® can be used with an O-Ring and Metal Housing or an abutment

OSSEAN® Surface is characterized by its fractal2 topography that extends beyond the nanoscale level. OSSEAN® has an extremely hydrophilic surface and is impregnated with Calcium Phosphate molecules that are incorporated into the surface structure at the molecular level. Due to this molecular impregnation, binding forces make the Calcium Phosphate exceptionally stable while preserving its bioactive properties.

Cement-Over™ Abutment System

Cement-Over™ Abutments, available in Straight, 15˚ Angled, Wide and Plastic Castable configurations, provide the clinician with an extensive range of prosthetic options. Cement-Over™ Abutments can be prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in place with resin cement, abutment and implant form one unit; resistant and as strong as a one-piece.

MDL2513MDL2513L MDL2013

Leng

th

Act

ive

Leng

th

Mini Drive-Lock (MDL®) is Intra-Lock’s

one-piece small diameter dental implant.

The system is ideal for long-term denture stabilization

or fixed prosthetics. MDL® is a true 'convertible'

implant with one-piece solid strength and two-piece

versatility. Patented* Cement-Over™ Abutments, simply fit

over the O-Ball Assembly and convert the implant from

removable to fixed or orthodontic treatment options. The

system’s unique Drive-Lock™ instruments reduce delivery and

placement to one fluid motion. Once in place, Intra-Lock’s

extremely hydrophilic, bio-active OSSEAN® Surface promotes

rapid early healing and increased biomechanical fixation1.

All implants are packaged with the Micro Metal Housing with O-Ring.

MDL® Mini Drive-Lock Implants, 2.0mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2010 MDL2011 MDL2013 MDL2015 MDL2018

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510 MDL2511 MDL2513 MDL2515 MDL2518

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, Long Collar, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510L MDL2511L MDL2513L MDL2515L MDL2518L

MDL® Mini Drive-Lock Implant, 2.0mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2013P

MDL® Mini Drive-Lock Implant, 2.5mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2513P

*The actual thread length is 2mm less than the catalog description, regardless of the height of the collar (2mm or 4mm).

Mini Drive-Lock Implants One Implant... Multiple Applications.

• “Long-Term”Applications

• OSSEAN ® SurfaceApplied to Collarand Body

• Cement -Over ™

Abutments

• DirectDelivery

OSSEAN® Surface is characterized by its fractal2 topography that extends beyond thenanoscale level. OSSEAN® has an extremely hydrophilic surface and is impregnatedwith Calcium Phosphate molecules that are incorporated into the surface structure atthe molecular level. Due to this molecular impregnation, binding forces make theCalcium Phosphate exceptionally stable while preserving its bioactive properties.

Universal ToolsMotorized Insertion

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Mini Drive-Lock™ Contra Angle Driver ... MDLCAD

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Tissue Punch Ø3mm ... RPCA3

Manual Insertion

Mini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Surgical Ratchet Wrench with standard 4x4mm connection, autoclavable ... SRA

MDL® DrillMini Drive-Lock Pilot Twist Drill

• Single Patient 1.2mm diameter - Sterile ..............................MDLSPD

• Single Patient 1.2mm diameter 13mm Long - Sterile ........MDLSPDL

Mini Drive-Lock Contra Angle Driver

• Contra Angle Driver .......................................................... MDLCAD

Mini Drive-Lock Ratchet Drivers

Use as an MDL® Hand Driver or with a Surgical Ratchet Wrench

• Mini Drive-Lock Ratchet Driver .......................................... MDLRD

• Mini Drive-Lock Ratchet Driver, Long................................ MDLRDL

Mini Drive-Lock Manual Wrench

• Connects to the Mini Drive-Lock Ratchet Driver................ MDLMW

Surgical Ratchet Wrench

• With standard 4 x 4mm connection, autoclavable .................... SRA

Tissue Punch

• Latch Tissue Punch ø3mm .................................................... RPCA3

Ref No.

Ref No.

MDLCAD

MDLSPD

MDLSPDL

MDLMW

SRA

MDLRDLMDLRD

RPCA3

Implant Insertion Instruments

Drills, Implant Insertion Instruments

Drive-Lock™ Technology

• Package-to-Site, Direct Delivery

• Contra-Angle or Ratchet Driver

• Ergonomic Design� � �

Predictable and efficient delivery and placement are achieved with Drive-Lock™ technology. MDL® Implants can be

removed from their sterile vial, transferred directly to the surgical site and threaded into place all in one fluid,

ergonomic motion.

Mini Drive-Lock Pilot Twist DrillSingle Patient 1.2mm diameter 13mm Long - Sterile ... MDLSPDL

MILO® Drills

The MILO™ Implant System is engineered for the anatomical andphysiological demands of long-term denture stabilization or thepermanent rehabilitation of single or multiple incisors. The simplifiedsurgical protocol is similar to that of a miniature implant, however,MILO™ has the added advantages of increased bone surface interface,improved load transfer capabilities and greater yield strength.

MILO™ Implants* are available in five lengths (10, 11.5, 13, 15 and17 mm) and two thread profiles (Fine Pitch and Wide Pitch) thatare engineered to address the clinical quality and quantity of bone.

MILO™ is a true convertible implantwith one-piece solid strength andtwo-piece versatility. The Cement-OverAbutments™** provide the clinicianwith an unsurpassed range ofprosthetic options.

IMPLANT INSERTION INSTRUMENTS

MDLCAD

MDLMW

MDLRD

MILO Contra Angle Driver• Standard Contra Angle .................................................................... MDLCAD

MILO™ Ratchet Drivers

Use as a MILO™ Hand Driver or with a Surgical Ratchet Wrench• Surgical Ratchet Driver ...................................................................... MDLRD• Surgical Ratchet Driver, Long............................................................ MDLRDL

MILO™ Manual Wrench• Connects to the Ratchet Driver ........................................................ MDLMW

Tissue Punch• Latch Tissue Punch ø3mm .................................................................... RPCA3

Surgical Ratchet Wrench• With standard 4x4mm connection, autoclavable ...................................... SRA

Surgical Box• Accommodates all MILO surgical instruments for Implant delivery and placement.

Laser etched Stainless steel insert .......................................................... MLSK

DRILLS• Lancer 0-2mm - Sterile .............................................................................. LD• Pilot Drill ø1.5mm Sterile ........................................................................ D15• Twist Drill ø2.0mm Sterile ........................................................................ D20• Final Drill ø2.5mm - Sterile ...................................................................... D25

MDLRDL

LD

D15

D20

D25

A N D A N C I L L A R Y I T E M S

RPCA3

SRA

ONE-PIECE IMPLANT. MULTIPLE APPLICATIONS.

3

* Pat. #7,033,174** Pat. #7,217,130

MILO™ can be usedwith an O-Ring

and Metal Housingor an abutment

StandardAbutment

DentureStabilization

WideAbutment

AngledAbutment

Lancer 0-2mm - Sterile ... LD

The MILO™ Implant System is engineered for the anatomical andphysiological demands of long-term denture stabilization or thepermanent rehabilitation of single or multiple incisors. The simplifiedsurgical protocol is similar to that of a miniature implant, however,MILO™ has the added advantages of increased bone surface interface,improved load transfer capabilities and greater yield strength.

MILO™ Implants* are available in five lengths (10, 11.5, 13, 15 and17 mm) and two thread profiles (Fine Pitch and Wide Pitch) thatare engineered to address the clinical quality and quantity of bone.

MILO™ is a true convertible implantwith one-piece solid strength andtwo-piece versatility. The Cement-OverAbutments™** provide the clinicianwith an unsurpassed range ofprosthetic options.

IMPLANT INSERTION INSTRUMENTS

MDLCAD

MDLMW

MDLRD

MILO Contra Angle Driver• Standard Contra Angle .................................................................... MDLCAD

MILO™ Ratchet Drivers

Use as a MILO™ Hand Driver or with a Surgical Ratchet Wrench• Surgical Ratchet Driver ...................................................................... MDLRD• Surgical Ratchet Driver, Long............................................................ MDLRDL

MILO™ Manual Wrench• Connects to the Ratchet Driver ........................................................ MDLMW

Tissue Punch• Latch Tissue Punch ø3mm .................................................................... RPCA3

Surgical Ratchet Wrench• With standard 4x4mm connection, autoclavable ...................................... SRA

Surgical Box• Accommodates all MILO surgical instruments for Implant delivery and placement.

Laser etched Stainless steel insert .......................................................... MLSK

DRILLS• Lancer 0-2mm - Sterile .............................................................................. LD• Pilot Drill ø1.5mm Sterile ........................................................................ D15• Twist Drill ø2.0mm Sterile ........................................................................ D20• Final Drill ø2.5mm - Sterile ...................................................................... D25

MDLRDL

LD

D15

D20

D25

A N D A N C I L L A R Y I T E M S

RPCA3

SRA

ONE-PIECE IMPLANT. MULTIPLE APPLICATIONS.

3

* Pat. #7,033,174** Pat. #7,217,130

MILO™ can be usedwith an O-Ring

and Metal Housingor an abutment

StandardAbutment

DentureStabilization

WideAbutment

AngledAbutment

The MILO™ Implant System is engineered for the anatomical andphysiological demands of long-term denture stabilization or thepermanent rehabilitation of single or multiple incisors. The simplifiedsurgical protocol is similar to that of a miniature implant, however,MILO™ has the added advantages of increased bone surface interface,improved load transfer capabilities and greater yield strength.

MILO™ Implants* are available in five lengths (10, 11.5, 13, 15 and17 mm) and two thread profiles (Fine Pitch and Wide Pitch) thatare engineered to address the clinical quality and quantity of bone.

MILO™ is a true convertible implantwith one-piece solid strength andtwo-piece versatility. The Cement-OverAbutments™** provide the clinicianwith an unsurpassed range ofprosthetic options.

IMPLANT INSERTION INSTRUMENTS

MDLCAD

MDLMW

MDLRD

MILO Contra Angle Driver• Standard Contra Angle .................................................................... MDLCAD

MILO™ Ratchet Drivers

Use as a MILO™ Hand Driver or with a Surgical Ratchet Wrench• Surgical Ratchet Driver ...................................................................... MDLRD• Surgical Ratchet Driver, Long............................................................ MDLRDL

MILO™ Manual Wrench• Connects to the Ratchet Driver ........................................................ MDLMW

Tissue Punch• Latch Tissue Punch ø3mm .................................................................... RPCA3

Surgical Ratchet Wrench• With standard 4x4mm connection, autoclavable ...................................... SRA

Surgical Box• Accommodates all MILO surgical instruments for Implant delivery and placement.

Laser etched Stainless steel insert .......................................................... MLSK

DRILLS• Lancer 0-2mm - Sterile .............................................................................. LD• Pilot Drill ø1.5mm Sterile ........................................................................ D15• Twist Drill ø2.0mm Sterile ........................................................................ D20• Final Drill ø2.5mm - Sterile ...................................................................... D25

MDLRDL

LD

D15

D20

D25

A N D A N C I L L A R Y I T E M S

RPCA3

SRA

ONE-PIECE IMPLANT. MULTIPLE APPLICATIONS.

3

* Pat. #7,033,174** Pat. #7,217,130

MILO™ can be usedwith an O-Ring

and Metal Housingor an abutment

StandardAbutment

DentureStabilization

WideAbutment

AngledAbutment

The MILO™ Implant System is engineered for the anatomical andphysiological demands of long-term denture stabilization or thepermanent rehabilitation of single or multiple incisors. The simplifiedsurgical protocol is similar to that of a miniature implant, however,MILO™ has the added advantages of increased bone surface interface,improved load transfer capabilities and greater yield strength.

MILO™ Implants* are available in five lengths (10, 11.5, 13, 15 and17 mm) and two thread profiles (Fine Pitch and Wide Pitch) thatare engineered to address the clinical quality and quantity of bone.

MILO™ is a true convertible implantwith one-piece solid strength andtwo-piece versatility. The Cement-OverAbutments™** provide the clinicianwith an unsurpassed range ofprosthetic options.

IMPLANT INSERTION INSTRUMENTS

MDLCAD

MDLMW

MDLRD

MILO Contra Angle Driver• Standard Contra Angle .................................................................... MDLCAD

MILO™ Ratchet Drivers

Use as a MILO™ Hand Driver or with a Surgical Ratchet Wrench• Surgical Ratchet Driver ...................................................................... MDLRD• Surgical Ratchet Driver, Long............................................................ MDLRDL

MILO™ Manual Wrench• Connects to the Ratchet Driver ........................................................ MDLMW

Tissue Punch• Latch Tissue Punch ø3mm .................................................................... RPCA3

Surgical Ratchet Wrench• With standard 4x4mm connection, autoclavable ...................................... SRA

Surgical Box• Accommodates all MILO surgical instruments for Implant delivery and placement.

Laser etched Stainless steel insert .......................................................... MLSK

DRILLS• Lancer 0-2mm - Sterile .............................................................................. LD• Pilot Drill ø1.5mm Sterile ........................................................................ D15• Twist Drill ø2.0mm Sterile ........................................................................ D20• Final Drill ø2.5mm - Sterile ...................................................................... D25

MDLRDL

LD

D15

D20

D25

A N D A N C I L L A R Y I T E M S

RPCA3

SRA

ONE-PIECE IMPLANT. MULTIPLE APPLICATIONS.

3

* Pat. #7,033,174** Pat. #7,217,130

MILO™ can be usedwith an O-Ring

and Metal Housingor an abutment

StandardAbutment

DentureStabilization

WideAbutment

AngledAbutment

Pilot Drill Ø1.5mm - Sterile ... D15

Twist Drill Ø2.0mm - Sterile ... D20

Final Drill Ø2.5mm - Sterile ... D25

MDL® AbutmentsCements over O-Ball Assembly for fixed bridges - Straight ... MDLSACements over O-Ball Assembly for fixed bridges - Angulated 15˚ ... MDLAA15Cements over O-Ball Assembly for fixed bridges - Wide ... WCAPlastic Castable Abutment for fixed bridges ... MDLPA

MDL® Impression CopingPick up Impression Coping ... MDLT

MDL® Laboratory AnalogReplicates the MDL® Implant and Abutment ... MDLA

Universal Components

Mini Drive-Lock™ Metal Housing with O-RingO-Ring encapsulated in MICRO Metal Housing ... MDLMMHO-Ring encapsulated in LARGE Metal Housing ... MDLMH

MILO®

3.0mm MILO® Wide Pitch ImplantsProsthetic Connection: 1.8mm O-Ball

Lengths: 10, 11.5, 13, 15 &17mmSurface treatment: Blasted + Progressively Acid Etched Titanium

10mm 11.5mm 13mm 15mm 17mm MLW3010 MLW3011 MLW3013 MLW3015 MLW3017

MDL2513MDL2513L MDL2013

Leng

th

Act

ive

Leng

th

Mini Drive-Lock (MDL®) is Intra-Lock’s

one-piece small diameter dental implant.

The system is ideal for long-term denture stabilization

or fixed prosthetics. MDL® is a true 'convertible'

implant with one-piece solid strength and two-piece

versatility. Patented* Cement-Over™ Abutments, simply fit

over the O-Ball Assembly and convert the implant from

removable to fixed or orthodontic treatment options. The

system’s unique Drive-Lock™ instruments reduce delivery and

placement to one fluid motion. Once in place, Intra-Lock’s

extremely hydrophilic, bio-active OSSEAN® Surface promotes

rapid early healing and increased biomechanical fixation1.

All implants are packaged with the Micro Metal Housing with O-Ring.

MDL® Mini Drive-Lock Implants, 2.0mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2010 MDL2011 MDL2013 MDL2015 MDL2018

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510 MDL2511 MDL2513 MDL2515 MDL2518

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, Long Collar, OSSEAN® Surface

*Length 10mm 11.5mm 13mm 15mm 18mmRef No. MDL2510L MDL2511L MDL2513L MDL2515L MDL2518L

MDL® Mini Drive-Lock Implant, 2.0mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2013P

MDL® Mini Drive-Lock Implant, 2.5mm Provisional, Non-OSSEAN®

*Length 13mmRef No. MDL2513P

*The actual thread length is 2mm less than the catalog description, regardless of the height of the collar (2mm or 4mm).

Mini Drive-Lock Implants One Implant... Multiple Applications.

• “Long-Term”Applications

• OSSEAN ® SurfaceApplied to Collarand Body

• Cement -Over ™

Abutments

• DirectDelivery

OSSEAN® Surface is characterized by its fractal2 topography that extends beyond thenanoscale level. OSSEAN® has an extremely hydrophilic surface and is impregnatedwith Calcium Phosphate molecules that are incorporated into the surface structure atthe molecular level. Due to this molecular impregnation, binding forces make theCalcium Phosphate exceptionally stable while preserving its bioactive properties.

MDL®

MDL® Mini Drive-Lock Implants, 2.0mm Diameter, OSSEAN Surface 10mm 11.5mm 13mm 15mm 18mm MDL2010 MDL2011 MDL2013 MDL2015 MDL2018

MDL® Mini Drive-Lock Implants, 2.5mm Diameter, OSSEAN Surface 10mm 11.5mm 13mm 15mm 18mm MDL2510 MDL2511 MDL2513 MDL2515 MDL2518

MILO® Prosthetic Components

MILO® AbutmentsCements over O-Ball Assembly for fixed bridges - Straight ... MLSACements over O-Ball Assembly for fixed bridges - Angulated 15˚ ... MLAA15Cements over O-Ball Assembly for crowns - Wide ... WCA3Plastic Castable Abutment for fixed bridges ... MLPA

MILO® Impression CopingPick up Impression Coping ... MLT

MILO® Laboratory AnalogReplicates the MILO™ Implant Platform ... MLA

MDL® O-Ring ReplacementsFor MICRO Housing (Quantity of 10) ... MDLMORFor LARGE Housing (Quantity of 10) ... MDLOR

Healing AbutmentsPlastic Healing Cap for Press Fit on O-Ball Assembly ... MLHC

YOUR GUIDE TO MDL® AND MILO® IMPLANTS

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

Cement-Over™ Abutments• Cements over O-Ball Assembly for fixed bridges

Straight ...................................................................................... MDLSA

• Cements over O-Ball Assembly for fixed bridges

Angulated 15° ...................................................................... MDLAA15

• Cements over O-Ball Assembly for fixed bridges

Wide ............................................................................................ WCA

• Plastic Castable Abutment for fixed bridges .............................. MDLPA

• Orthodontic Abutment fits over O-Ball Assembly ..................... MDLOA

Healing Abutments

• Plastic Healing Cap for Press Fit on O-Ball Assembly.................. MLHC

Mini Drive-Lock Metal Housing with O-Ring

• O-Ring encapsulated in MICRO Metal Housing .................. MDLMMH

• O-Ring encapsulated in LARGE Metal Housing ...................... MDLMH

MDL® O-Ring Replacements

• For MICRO Housing (Quantity of 10).................................... MDLMOR

• For LARGE Housing (Quantity of 10)........................................ MDLOR

Mini Drive-Lock Impression Coping

• Pick up Impression Coping .......................................................... MDLT

Mini Drive-Lock Laboratory Analog

• Replicates the MDL® Implant and Abutment................................ MDLA

MDLA

MDLOR MDLMOR

MDLMMHMDLMH

MLHC

Ref No.

MDLSA MDLAA15 WCA

MDLPA

MDLT

MDLOA

Prosthetic Components

Cement-Over™ Abutments*, available in Straight, 150 Angled, Wide, Plastic

Castable, and Orthodontic configurations, provide the clinician with an

unsurpassed range of prosthetic options. Cement-Over™ Abutments* can be

prepared extra orally and simply fit over the O-Ball Assembly. Once cemented in

place with resin cement, abutment and implant form one unit; resistant and strong

as a one-piece. An Analog and Impression Coping complement the system.

Cement-Over™ Abutment System

The thread length is 2mm less than the catalogue length

description

MDL® Prosthetic Components