Uniform scan images of all layers, from the vitreous through to the sclera
Limbus to limbus capture of anterior segment through 16mm scan
Invisible 1,050nm light source for patient comfort
Visualize new depths of retinal pathology
Unrivaled penetration of media opacities and pathology
Automated segmentation of 7 retinal layers, including auto choroidal thickness assessment
Normative Database for early detection of disease
Progression analysis for continued monitoring of patients
The Ultimate Advanced Diagnostic Tool / ient Work Flow
Every Layer, with Every Scan
Unique Confidence in Diagnosis
Swept Source OCT with Multimodal True Fundus Imaging
First commercially available posterior “Swept Source” OCT unit with combined anterior scan capability
1,050nm Swept Source wavelength allows deeper penetration of ophthalmic structures
Highest scan speed available at 100,000 A-Scans/second*1
Multifunctional Swept Source OCT, True Color Fundus capture, red free, autofluorescence, fluorescein angiography & Swept Source anterior scans
Swept Source OCT Image Color FA FAF
*1 According to Topcon survey - Oct. 2014*2 DRI OCT-1 Triton Series consists of DRI OCT-1 Model Triton : SS OCT + Color, Digital Red free DRI OCT-1 Model Triton (plus) : SS OCT + Color, Digital Red free + Fluorescein Angiography + Auto Fluorescein
Not available for sale in the US / Not available in all countries, please check with your distributor for availability in your country
Courtesy:Prof. P. E. Stanga, Manchester Royal Eye Hospital, Manchester Vision Regeneration (MVR) Lab at NIHR/ Welcome Trust Manchester CRF & University of Manchester
rdDRI OCT-1 TritonSeries
3 Generation OCT : Swept Source*2
Specifications
Color, FA*, FAF*, Red-free**45°Equivalent 30° (Digital Zoom )34.8mmNormal:φ 4.0mm or moreSmall pupil diameter: φ 3.3mm or more
Horizontal Within 3 to 12mmVertical Within 3 to 12mm3D scanLinear scan (Line-scan/Cross-scan/Radial-scan)100,000 A-Scans per second20μmOptical function: 8μmDigital: 2.6μm (when taking two or more pictures)φ 2.5mm or more
Internal fixation target : Dot matrix type organic EL The display position can be changed and adjusted. The displaying method can be changed.Peripheral fixation target : This is displayed according to the internal fixation target displayed position.External fixation target
IR17mm
17mmHorizontal Within 3 to 16mmVertical Within 3 to 16mm3D scanLinear scan (Line-scan/Radial-scan)100,000 A-Scans per secondInternal fixation targetExternal fixation target
Voltage: 100-240V Frequency: 50-60Hz250VA
320~359 mm(W) X 523~554 mm(D) X 560~590 mm(H)21.8kg (DRI OCT Triton)23.8kg(DRI OCT Triton plus)
Observation & Photography of Fundus ImageScan ModePicture Angle
Operating DistancePhotographable Diameter of Pupil
Observation & Photography of Fundus Image Scanning Range
Scan Patterns
Scan SpeedLateral ResolutionIn-depth Resolution
Photographable Diameter of PupilObservation & Photography of Fundus Image / Fundus TomogramFixation target
Observation & photography of anterior segment***Photography typeOperating distanceObservation & photography of anterior segment tomogram***Operating distanceScan range (on cornea)
Scan pattern
Scan speedFixation target
Electric RatingPower Source
Power SupplyDimensions / WeightDimensionsWeight
* FA photography and FAF photography can be performed in only DRI OCT Triton plus.** In this digital red-free photography, the color image is processed and is displayed as a pseudo red-free photographed image.*** Observation & photography of anterior segment can be performed only when the anterior segment attachment kit is used.The design and the specifications are subject to change without prior notice for the product improvement.
DRI OCT-1Triton series