*DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE...

7
DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP PRIME-RITE SERIES AUTOMATIC TRAP PRIMER WITH MULTIPLE OUTLET DISTRIBUTION TP-"A"-AUTOMATIC TRAP PRIMER FOR USE IN PUBLIC AREAS. BASIS FOR DESIGN: WOODFORD #24P WITH LOOSE TEE KEY AND VACUUM BREAKER HOSE BIBB, CHROME PLATED HB-HOSE BIBB LOOSE KEY BASIS FOR DESIGN: WOODFORD #24P HOSE BIBB WITH WHEEL HANDLE WITH VACUUM BREAKER, ROUGH BRASS, HB-HOSE BIBB DEVICE, GASKET SEAL THREADED PLUG, V.P. SCREWS IN COVER. PROVIDE 24" x 12" BASIS FOR DESIGN: JAY R. SMITH FIG. 4261 C.I. FLANGED HOUSING WITH HEAVY DUTY C.I. COVER, LIFTING BASIS FOR DESIGN: JAY R. SMITH #700 FOR MASONRY WALLS AND #700-M31 FOR METAL STUD WALLS. LAVATORY-WALL HUNG SUPPORT BRONZE STRAINER, SPEEDI-SET OUTLET CONNECTION AND TRAP PRIMER CONNECTION. BASIS FOR DESIGN: JAY R. SMITH FIG. 2005-B6 SERIES C.I. FLOOR DRAIN WITH 6" DIAMETER SQUARE NICKEL FD "G" - FLOOR DRAINS-GENERAL/RESTROOMS CONCRETE PAD FLUSH WITH SURFACE. YCO-EXTERIOR UNSURFACED AREAS DEVICE, GASKET SEAL THREADED PLUG, V.P. SCREWS IN COVER. BASIS FOR DESIGN: JAY R. SMITH FIG. 4261 C.I. FLANGED HOUSING WITH HEAVY DUTY C.I. COVER, LIFTING YCO-EXTERIOR PAVED/CONCRETE AREAS SCREW, SPEEDI-SET OUTLET CONNECTION. ROUND NICKEL BRONZE TOP COMPLETE WITH STAINLESS STEEL CARPET MARKER WITH SECURING BASIS FOR DESIGN: JAY R. SMITH FIG. 4020-Y C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG, ADJUSTABLE FCO-CARPETED FLOORS SCREW, SPEEDI-SET OUTLET CONNECTION. REMOVAL, ADJUSTABLE ROUND NICKEL BRONZE TOP RECESSED FOR TILE WITH SECURING BASIS FOR DESIGN: JAY R. SMITH FIG. 4151 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY FCO-TILE FLOORS CONNECTION. REMOVAL, ADJUSTABLE ROUND CAST IRON TOP WITH SECURING SCREW, SPEEDI-SET OUTLET BASIS FOR DESIGN: JAY R. SMITH FIG. 4220 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASY FCO-CONCRETE FLOORS BRONZE ROUND FRAME AND COVER WITH SECURING SCREWS. BASIS FOR DESIGN: JAY R. SMITH FIG. 4436 C.I. FERRULE FOR NO HUB OR SERVICE WEIGHT PIPE, NICKEL WCO-WALL CLEANOUT - FINISHED AREAS THICK STEEL BAR STOCK. BASIS FOR DESIGN: JAY R. SMITH FIG. 4420 CAST BRONZE COUNTERSUNK PLUG WITH SLOT TO RECEIVE 1/2" CO-EXPOSED CLEANOUT - UNFINISHED AREAS ZURN, JOSAM, WADE, WATTS AND PRECISION PLUMBING PRODUCTS UNLESS OTHERWISE INDICATED NUMBERS ARE JAY R. SMITH. APPROVED EQUAL PRODUCTS: ICE MAKER SUPPLY BASIS FOR DESIGN: GUY GRAY MODEL BIM875 16 GAUGE SUPPLY WITH 1/2" INLET, AND 1/4" OUTLET ANGLE VALVE. PLUMBING NOTES REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALL PLUMBING FIXTURES. ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2012 INTERNATIONAL PLUMBING CODE WITH ALL APPLICABLE STATE OF GEORGIA AMENDMENTS . ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FR0M THE BUILDING STRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROM CEILING TILES. WATER PIPING ROUTED ABOVE CEILING AND IN EXTERIOR WALLS SHALL BE ROUTED ON HEATED SIDE (UNDERSIDE) OF CEILING INSULATION AND HEATED SIDE (INSIDE) OF WALL INSULATION. SANITARY AND DRAINAGE PIPING 2½" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM. TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET FLUSH WITH FINISHED FLOOR. TRAP PRIMERS ARE TO BE PROVIDED ON ALL FLOOR DRAINS AND HUB DRAINS. TP "A" AUTOMATIC TRAP PRIMERS ARE TO BE PROVIDED IN ALL REQUIRED LOCATIONS. PLUMBING AND FIRE PROTECTION PIPING IS NOT TO BE INSTALLED IN ELECTRICAL ROOMS, CLOSETS, TELEPHONE ROOMS, OR ELEVATOR EQUIPMENT ROOMS EXCEPT PIPING SERVING THAT SPECIFIC ROOM. LOCATE ALL SECTIONAL OR MAIN CONTROL VALVES WITHIN 1'-0" FROM ACCESS PANELS, CEILING TILES, OR OTHER POINT OF ACCESS. ALL COLD WATER, HOT WATER AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALL BE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS. PROVIDE SHOCK ABSORBERS SIZED PER PDI SPECIFICATIONS ON ALL DOMESTIC WATER LINES SERVING FLUSH VALVE FIXTURES, WASHING MACHINES SUPPLIES, PRV STATIONS AND OTHER INSTALLATIONS WITH QUICK CLOSING VALVES. PROVIDE REDUCED PRESSURE BACKFLOW PREVENTORS AT ALL DOMESTIC WATER CONNECTIONS TO MECHANICAL EQUIPMENT AS REQUIRED BY LOCAL CODE AND AUTHORITIES. BACKFLOW PREVENTORS ARE TO BE LOCATED WITH A PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOP ON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS. THE CONSTRUCTION PROFESSIONAL SHALL COORDINATE ELECTRICAL CHARACTERISTICS AND REQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND THE ELECTRICAL CONSTRUCTION PROFESSIONAL, AND SHALL FURNISH EQUIPMENT WIRED FOR THE VOLTAGES SHOWN THEREIN. ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUM SPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY. ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUM PERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE. ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRE STOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIER PRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195 COMPOSITE PANEL, FS195 WRAP/SRINK, TREMCO, HILTI, METACAULK, NELSON, APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS. ALSO, REFER TO DIVISION 7 - THERMAL AND MOISTURE PROTECTION. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. STAINLESS STEEL BOX AND FRAME INTEGRAL VACUUM BREAKER, NICKEL BRONZE FACE, AND BASIS FOR DESIGN: JAY R. SMITH FIG. 5509-QT NON FREEZE 3/4" CAST BRONZE HYDRANT WITH RECESSED SIZED IN ACCORDANCE WITH WALL THICKNESS. NFWH-WALL HYDRANT-EXTERIOR CAST IRON GRATE WITH INTEGRAL 4" FUNNEL, SPEEDI-SET OUTLET CONNECTION. BASIS FOR DESIGN: JAY R. SMITH FIG. 3715 SERIES CAST IRON 12" DIAMETER DRAIN WITH SEDIMENT BUCKET, FD "M" -FLOOR DRAINS-GENERAL PURPOSE/MECHANICAL ROOM 18. ALL VENT THRU ROOF PENETRATIONS SHALL BE ROUTED TO TERMINATE AT THE LEAST VISIBLE LOCATION FROM THE ENTRY VIEW. BASIS FOR DESIGN: JAY R. SMITH FIG. 5609-QT NON FREEZE 3/4" CAST BRONZE EXPOSED HYDRANT INTEGRAL VACUUM BREAKER, NICKEL BRONZE FACE, AND NFHB-HOSEBIBB-EXTERIOR SIZED IN ACCORDANCE WITH WALL THICKNESS. POSITION AT ALL FLUSH VALVES, WASHING MACHINE SUPPLIES, DISHWASHERS, PRV STATIONS, IN ACCORDANCE WITH PDI STANDARD WH-201. AND OTHER QUICK CLOSING VALVES, SOLENOIDS AND PLUMBING FIXTURES. LOCATE AND SIZE AS INDICATED ON DRAWINGS. WHERE NOT SHOWN ON DRAWINGS, LOCATE AND SIZE BASIS FOR DESIGN: P.P.P. SYSTEM RATED PLUS SERIES COPPER WATER HAMMER ARRESTORS. INSTALL IN AN UPRIGHT WATER HAMMER ARRESTORS MINIMUM OF 1'-0" CLEARANCE AT THE LOWEST POINT AND AT NO MORE THAN 5'-0" ABOVE FLOOR AT THE HIGHEST POINT OF THE DEVICE. OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR PROVIDE FR-12 SERIES IN ALL FIRE RATED WALLS. BASIS FOR DESIGN: JAY R. SMITH FIG. 5560-QTH: NON FREEZE 3/4" CAST BRONZE RECESSED BOX WITH HW/CW HYDRANTS WITH INTEGRAL VACUUM BREAKER. NFWH-HW/CW TP TRAP PRIMER WALL HYDRANT/NON-FREEZE WALL HYDRANT VTR WH/NFWH YCO WCO UP V --- VENT THRU ROOF YARD CLEANOUT WALL CLEANOUT PIPING TURNING UP VENT PIPING UNION EMERGENCY RAIN LEADER COMBINATION WASTE & VENT SOIL, WASTE PIPING (BELOW GROUND) SOIL, WASTE PIPING (ABOVE GROUND) HOSE BIBB/NON-FREEZE HOSE BIBB REDUCED PRESSURE BACKFLOW PREVENTOR PRESSURE REDUCING VALVE HOT WATER RETURN PIPING GAS PIPING - MEDIUM PRESSURE EMERGENCY ROOF DRAIN COLD WATER PIPING CW HD HUB DRAIN ST S S PD ST S,W S,W RPBP RD PRV STORM DRAINAGE PIPING ROOF DRAIN --- PD HWR HW PUMPED DISCHARGE P-TRAP HOT WATER PIPING MG G ERL CWV HB/NFHB H.C. GV MG G HANDICAPPED GATE/BALL VALVE GAS PIPING - LOW PRESSURE FD FCO ERL ERD DN CWV FLOOR DRAIN FLOOR CLEANOUT PIPING TURNING DOWN CD CA SYMBOL COMPRESSED AIR CONDENSATE DRAIN CV CD B/F B/G CA B/C CHECK VALVE BELOW COUNTER BELOW GRADE BELOW FLOOR A/P AFG AFF A/F ABBREVIATION A/C AD ACCESS PANEL ABOVE FINISHED GRADE ABOVE FINISHED FLOOR ABOVE FLOOR ABOVE CEILING AREA DRAIN DESCRIPTION PLUMBING LEGEND SA SHOCK ABSORBER HOT WATER RETURN BALANCING VALVE BV MINIMUM SIZE UTILITY TO FIXTURE FIXTURE SCHEDULE URINAL WATER CLOSET - PUBLIC WC-1/WC-1H MOP SINK MS-1 URL-1/URL-1H FIXTURE # FIXTURE TYPE 4" 3" 2" 1/2" --- WASTE CONNECTION --- 1/2" 1/2" 3/4" ELECTRIC WATER COOLER EWC-1 1-1/2" 1/2" 1/2" 3. ALL UNITS SHALL MEET ASHRAE 90.1-2007 AND ALL LOCAL CODE REQUIREMENTS. 2. PROVIDE GATE/BALL VALVES WITH UNIONS AND DIELECTRIC FITTINGS ON WATER INLET AND OUTLET CONNECTIONS. NOTES: 1. PROVIDE T&P RELIEF VALVE AND VACUUM RELIEF VALVE WATER HEATER SCHEDULE SYMBOL LOCATION/ GALLONS STORAGE CAPACITY REC./TEMP. RISE GPH MODEL NO. NOTES TEMPERATURE OUTLET GAS CRITERIA FLUE SIZE INPUT BTU 4. DESIGN BASIS: A. O. SMITH CUSTOM Xi SERIES LAVATORY - PUBLIC L-1/L-1H 1-1/4" 1/2" 1/2" WHE-1 MECHANICAL 1525/ 61/100° 140°F 1-4 -- -- LAVATORY - WALL-HUNG L-2H 1-1/4" 1/2" 1/2" 120 BREAK ROOM SINK BRS-1 1-1/2" 1/2" 1/2" HOT WATER SUPPLY COLD WATER SUPPLY EMERGENCY EYEWASH (EW-1): WALL MOUNTED, STAINLESS STEEL BOWL. EYEWASH SHALL INCLUDE TWO SPRAY HEADS ON ON SUPPLY ARMS. BASIS FOR DESIGN: GUARDIAN MODEL G1814. S-1 MEETING ROOM SINK 1-1/2" 1/2" 1/2" DSE-120 NOTES: PUMP SCHEDULE SYMBOL NOTES SERVICE/ LOCATION TYPE FLOW (GPM) (PSI/FT) HEAD RPM HP 1. BASIS OF DESIGN: BELL & GOSSETT NBF-33. 1 INLINE MECHANICAL 1525 DOMESTIC HWR/ HWRP-1 3.54/9 4.5 1725 1/8 TIME OF DAY OF TEST UPON AWARD OF THE CONTRACT, THE FIRE PROTECTION CONTRACTOR SHALL PERFORM A FLOW TEST ON THE TWO HYDRANTS NEAREST THE SITE THE FOLLOWING WATER PRESSURE/FLOW DATA WAS OBTAINED FROM: AND FORWARD THE TEST DATA TO THE ENGINEER AND ARCHITECT FLOW TEST DATA SCHEDULE 62 PSI 55 PSI N/A 1,100 GPM RESIDUAL PRESSURE STATIC PRESSURE LOCATION OF TEST HYDRANT ELEVATION OF TEST HYDRANT DATE OF TEST FLOW (GPM) N/A N/A STATESBORO WATER DEPARTMENT N/A HS-1 LAB HAND SINK 1-1/2" 1/2" 1/2" NOTES: AIR COMPRESSOR SCHEDULE SYMBOL 1 NOTES LOCATION TANK SIZE CAPACITY 120 GALLONS MECHANICAL 1525 AC-1/2 24.1 SCFM AT 125 PSI 1. BASIS OF DESIGN: RECIPROCATING AIR COMPRESSOR, INGERSOLL RAND 2-2475E7.5-P TYPE 30. *LISTED MANUFACTURERS ARE BASIS FOR DESIGN OUTLET CONNECTION, CAST IRON DOME. BASIS FOR DESIGN: JAY R. SMITH FIG. 1080-Y C.I. BODY WITH 2" HIGH WATER DAM AND CAST IRON, NO HUB ERD-EMERGENCY ROOF DRAIN CONNECTION, CAST IRON DOME. CAST IRON, ADJUSTABLE EXTENSION TO SUIT INSULATION THICKNESS, NO HUB OUTLET BASIS FOR DESIGN: JAY R. SMITH FIG. 1015-Y-RC. C.I. BODY WITH FLASHING CLAMP AND SUMP RECEIVER CLAMP, RD-ROOF DRAINS-INSULATED ROOF BASIS FOR DESIGN: JAY R. SMITH FIG. 1770, WALL MOUNTED CAST IRON BODY AND FLANGE, NICKEL BRONZE FINISH DOWNSPOUT NOZZLE LAB HAND SINK(HS-1): WALL MOUNTED SINGLE BOWL LAB HAND SINK WITH DECK MOUNTED GOOSE NECK FAUCET, 1-1/2" P-TRAP, & P-TRAP INSULATION KIT. BASIS FOR DESIGN: ADVANCE TABCO 7-PS-75 THERMAL EXPANSION TANKS TAG ELECTRICAL CRITERIA INPUT KW 15 NOTES: 1. BASIS OF DESIGN: AMTROL. ACCEPTABLE MANUFACTURERS: WATTS, WESSELS MANUFACTURER & MODEL NO. ET-1 AMTROL MODEL# ST-12C CONNECTION SIZE ¾" NPT MAX WORKING PRESSURE TANK VOLUME ACCEPTANCE FACTOR 0.5 6.4 GAL 150 PSIG THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTS AND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN AUTHORIZATION AND PERMISSION. COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC. /Volumes/CCCA-data/Projects/2016/16002.00 - Ogeechee Plant Operations & Workforce Training Center/Design/ArchiCad/161127- Ogeechee Tech .pln - 11/14/16 SHEET TITLE RELEASED FOR CONSTRUCTION OGEECHEE TECHNICAL COLLEGE PLANT OPERATIONS AND WORKFORCE TRAINING CENTER TCSG-330 One Joseph E. Kennedy Blvd Statesboro, GA 30458 Project Number : 16002.00 REVISION/SUBMISSION SD SUBMITTAL - 11.28.16 DD SUBMITTAL - 01.11.17 CD SUBMITTAL - 03.22.17 DRG RESPONSES - 05.04.17 DRG RESPONSES - 06.16.17 ISSUE FOR BID - 07.17.17 NOTES, LEGENDS, SCHEDULES - PLUMBING P-001 Project Number - Drawn By - Checked By - Jordan & Skala Engineers 6069 South Ft. Apache Rd., Suite 100 Las Vegas, NV 89148 p. 702.362.5111 f. 702.362.5554 1610287 DA EE *DRAWING LIST PLUMBING SHEET NUMBER SHEET NAME P-001 NOTES, LEGENDS, SCHEDULES - PLUMBING P-002 DETAILS - PLUMBING P-101 FLOOR PLAN - NORTH WING - PLUMBING P-102 FLOOR PLAN - SOUTH WING - PLUMBING P-103 ROOF PLAN - NORTH WING - PLUMBING P-104 ROOF PLAN - SOUTH WING - PLUMBING P-110 ENLARGED PLANS - PLUMBING

Transcript of *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE...

Page 1: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

DRAINAGE PRODUCTS/SPECIALTIES

FOR USE IN NON-PUBLIC AREAS.

UNITS AS REQUIRED.BASIS FOR DESIGN: PPP PRIME-RITE SERIES AUTOMATIC TRAP PRIMER WITH MULTIPLE OUTLET DISTRIBUTIONTP-"A"-AUTOMATIC TRAP PRIMER

FOR USE IN PUBLIC AREAS.BASIS FOR DESIGN: WOODFORD #24P WITH LOOSE TEE KEY AND VACUUM BREAKER HOSE BIBB, CHROME PLATEDHB-HOSE BIBB LOOSE KEY

BASIS FOR DESIGN: WOODFORD #24P HOSE BIBB WITH WHEEL HANDLE WITH VACUUM BREAKER, ROUGH BRASS,HB-HOSE BIBB

DEVICE, GASKET SEAL THREADED PLUG, V.P. SCREWS IN COVER. PROVIDE 24" x 12"BASIS FOR DESIGN: JAY R. SMITH FIG. 4261 C.I. FLANGED HOUSING WITH HEAVY DUTY C.I. COVER, LIFTING

BASIS FOR DESIGN: JAY R. SMITH #700 FOR MASONRY WALLS AND #700-M31 FOR METAL STUD WALLS.LAVATORY-WALL HUNG SUPPORT

BRONZE STRAINER, SPEEDI-SET OUTLET CONNECTION AND TRAP PRIMER CONNECTION.BASIS FOR DESIGN: JAY R. SMITH FIG. 2005-B6 SERIES C.I. FLOOR DRAIN WITH 6" DIAMETER SQUARE NICKELFD "G" - FLOOR DRAINS-GENERAL/RESTROOMS

CONCRETE PAD FLUSH WITH SURFACE.

YCO-EXTERIOR UNSURFACED AREAS

DEVICE, GASKET SEAL THREADED PLUG, V.P. SCREWS IN COVER.BASIS FOR DESIGN: JAY R. SMITH FIG. 4261 C.I. FLANGED HOUSING WITH HEAVY DUTY C.I. COVER, LIFTINGYCO-EXTERIOR PAVED/CONCRETE AREAS

SCREW, SPEEDI-SET OUTLET CONNECTION.ROUND NICKEL BRONZE TOP COMPLETE WITH STAINLESS STEEL CARPET MARKER WITH SECURINGBASIS FOR DESIGN: JAY R. SMITH FIG. 4020-Y C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG, ADJUSTABLEFCO-CARPETED FLOORS

SCREW, SPEEDI-SET OUTLET CONNECTION.REMOVAL, ADJUSTABLE ROUND NICKEL BRONZE TOP RECESSED FOR TILE WITH SECURINGBASIS FOR DESIGN: JAY R. SMITH FIG. 4151 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASYFCO-TILE FLOORS

CONNECTION.REMOVAL, ADJUSTABLE ROUND CAST IRON TOP WITH SECURING SCREW, SPEEDI-SET OUTLETBASIS FOR DESIGN: JAY R. SMITH FIG. 4220 C.I. CLEANOUT WITH GASKET SEAL THREADED PLUG FOR EASYFCO-CONCRETE FLOORS

BRONZE ROUND FRAME AND COVER WITH SECURING SCREWS.BASIS FOR DESIGN: JAY R. SMITH FIG. 4436 C.I. FERRULE FOR NO HUB OR SERVICE WEIGHT PIPE, NICKELWCO-WALL CLEANOUT - FINISHED AREAS

THICK STEEL BAR STOCK.BASIS FOR DESIGN: JAY R. SMITH FIG. 4420 CAST BRONZE COUNTERSUNK PLUG WITH SLOT TO RECEIVE 1/2"CO-EXPOSED CLEANOUT - UNFINISHED AREAS

ZURN, JOSAM, WADE, WATTS AND PRECISION PLUMBING PRODUCTSUNLESS OTHERWISE INDICATED NUMBERS ARE JAY R. SMITH. APPROVED EQUAL PRODUCTS:

ICE MAKER SUPPLYBASIS FOR DESIGN: GUY GRAY MODEL BIM875 16 GAUGE SUPPLY WITH 1/2" INLET, AND 1/4" OUTLET ANGLE VALVE.

PLUMBING NOTES

REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND ELEVATIONS OF ALLPLUMBING FIXTURES.

ALL PLUMBING WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE 2012 INTERNATIONALPLUMBING CODE WITH ALL APPLICABLE STATE OF GEORGIA AMENDMENTS .

ALL PIPING ABOVE GRADE SHALL BE PROPERLY SUPPORTED FR0M THE BUILDINGSTRUCTURE AND SHALL NOT REST ON CEILING TILES OR BE SUPPORTED FROMCEILING TILES.

WATER PIPING ROUTED ABOVE CEILING AND IN EXTERIOR WALLS SHALL BE ROUTEDON HEATED SIDE (UNDERSIDE) OF CEILING INSULATION AND HEATED SIDE (INSIDE)OF WALL INSULATION.

SANITARY AND DRAINAGE PIPING 2½" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOTMINIMUM, PIPING 3" AND LARGER SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM.

TOPS OF ALL FLOOR DRAINS AND CLEANOUTS SHALL BE SET FLUSH WITH FINISHED FLOOR.

TRAP PRIMERS ARE TO BE PROVIDED ON ALL FLOOR DRAINS AND HUB DRAINS.TP "A" AUTOMATIC TRAP PRIMERS ARE TO BE PROVIDED IN ALL REQUIRED LOCATIONS.

PLUMBING AND FIRE PROTECTION PIPING IS NOT TO BE INSTALLED IN ELECTRICAL ROOMS,CLOSETS, TELEPHONE ROOMS, OR ELEVATOR EQUIPMENT ROOMS EXCEPT PIPINGSERVING THAT SPECIFIC ROOM.

LOCATE ALL SECTIONAL OR MAIN CONTROL VALVES WITHIN 1'-0" FROM ACCESSPANELS, CEILING TILES, OR OTHER POINT OF ACCESS.

ALL COLD WATER, HOT WATER AND DRAIN PIPING AT HANDICAPPED FIXTURES SHALLBE INSULATED WITH HANDI-LAV GUARD MODELS 102 AND 105 INSULATION KITS.

PROVIDE SHOCK ABSORBERS SIZED PER PDI SPECIFICATIONS ON ALL DOMESTIC WATERLINES SERVING FLUSH VALVE FIXTURES, WASHING MACHINES SUPPLIES, PRV STATIONSAND OTHER INSTALLATIONS WITH QUICK CLOSING VALVES.

PROVIDE REDUCED PRESSURE BACKFLOW PREVENTORS AT ALL DOMESTIC WATERCONNECTIONS TO MECHANICAL EQUIPMENT AS REQUIRED BY LOCAL CODEAND AUTHORITIES. BACKFLOW PREVENTORS ARE TO BE LOCATED WITH A

PROVIDE MANUFACTURED EXPANSION DEVICE OR FABRICATED EXPANSION LOOPON ALL PIPING SYSTEMS CROSSING BUILDING EXPANSION JOINTS.

THE CONSTRUCTION PROFESSIONAL SHALL COORDINATE ELECTRICAL CHARACTERISTICS ANDREQUIREMENTS OF ALL PLUMBING EQUIPMENT WITH THE ELECTRICAL DRAWINGS AND THE ELECTRICALCONSTRUCTION PROFESSIONAL, AND SHALL FURNISH EQUIPMENT WIRED FOR THEVOLTAGES SHOWN THEREIN.

ALL PLUMBING EQUIPMENT, PIPING, INSULATION, ETC. INSTALLED IN HVAC PLENUMSPACES SHALL MEET CODE REQUIREMENTS FOR SMOKE AND COMBUSTIBILITY.

ALL PLUMBING EQUIPMENT AND SYSTEMS SHALL BE GUARANTEED FOR A MINIMUMPERIOD OF ONE YEAR AFTER FINAL ACCEPTANCE.

ALL PIPE PENETRATIONS OF FIRE AND/OR SMOKE RATED ASSEMBLIES SHALL BE FIRESTOPPED AS REQUIRED TO RESTORE ASSEMBLY TO ORIGINAL INTEGRITY. FIRE BARRIERPRODUCTS SHALL BE AS MANUFACTURED BY 3M COMPANY, CP25 CAULK, CS195COMPOSITE PANEL, FS195 WRAP/SRINK, TREMCO, HILTI, METACAULK, NELSON,

APPLICATIONS, OR EQUIVALENT SYSTEM AS APPROVED BY LOCAL CODE OFFICIALS.ALSO, REFER TO DIVISION 7 - THERMAL AND MOISTURE PROTECTION.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

STAINLESS STEEL BOX AND FRAME INTEGRAL VACUUM BREAKER, NICKEL BRONZE FACE, ANDBASIS FOR DESIGN: JAY R. SMITH FIG. 5509-QT NON FREEZE 3/4" CAST BRONZE HYDRANT WITH RECESSED

SIZED IN ACCORDANCE WITH WALL THICKNESS.

NFWH-WALL HYDRANT-EXTERIOR

CAST IRON GRATE WITH INTEGRAL 4" FUNNEL, SPEEDI-SET OUTLET CONNECTION.BASIS FOR DESIGN: JAY R. SMITH FIG. 3715 SERIES CAST IRON 12" DIAMETER DRAIN WITH SEDIMENT BUCKET,FD "M" -FLOOR DRAINS-GENERAL PURPOSE/MECHANICAL ROOM

18. ALL VENT THRU ROOF PENETRATIONS SHALL BE ROUTED TO TERMINATE AT THELEAST VISIBLE LOCATION FROM THE ENTRY VIEW.

BASIS FOR DESIGN: JAY R. SMITH FIG. 5609-QT NON FREEZE 3/4" CAST BRONZE EXPOSED HYDRANTINTEGRAL VACUUM BREAKER, NICKEL BRONZE FACE, AND

NFHB-HOSEBIBB-EXTERIOR

SIZED IN ACCORDANCE WITH WALL THICKNESS.

POSITION AT ALL FLUSH VALVES, WASHING MACHINE SUPPLIES, DISHWASHERS, PRV STATIONS,

IN ACCORDANCE WITH PDI STANDARD WH-201.

AND OTHER QUICK CLOSING VALVES, SOLENOIDS AND PLUMBING FIXTURES. LOCATE ANDSIZE AS INDICATED ON DRAWINGS. WHERE NOT SHOWN ON DRAWINGS, LOCATE AND SIZE

BASIS FOR DESIGN: P.P.P. SYSTEM RATED PLUS SERIES COPPER WATER HAMMER ARRESTORS. INSTALL IN AN UPRIGHTWATER HAMMER ARRESTORS

MINIMUM OF 1'-0" CLEARANCE AT THE LOWEST POINT AND AT NO MORE THAN 5'-0"ABOVE FLOOR AT THE HIGHEST POINT OF THE DEVICE.

OR PSS 7900 SERIES SYSTEMS AS RECOMMENDED BY MANUFACTURER FOR PARTICULAR

PROVIDE FR-12 SERIES IN ALL FIRE RATED WALLS.

BASIS FOR DESIGN: JAY R. SMITH FIG. 5560-QTH: NON FREEZE 3/4" CAST BRONZE RECESSED BOXWITH HW/CW HYDRANTS WITH INTEGRAL VACUUM BREAKER.

NFWH-HW/CW

TP TRAP PRIMER

WALL HYDRANT/NON-FREEZE WALL HYDRANT

VTR

WH/NFWH

YCO

WCO

UP

V

---

VENT THRU ROOF

YARD CLEANOUT

WALL CLEANOUT

PIPING TURNING UP

VENT PIPING

UNION

EMERGENCY RAIN LEADER

COMBINATION WASTE & VENT

SOIL, WASTE PIPING (BELOW GROUND)

SOIL, WASTE PIPING (ABOVE GROUND)

HOSE BIBB/NON-FREEZE HOSE BIBB

REDUCED PRESSURE BACKFLOW PREVENTOR

PRESSURE REDUCING VALVE

HOT WATER RETURN PIPING

GAS PIPING - MEDIUM PRESSURE

EMERGENCY ROOF DRAIN

COLD WATER PIPINGCW

HD HUB DRAIN

ST

S

S

PD

ST

S,W

S,W

RPBP

RD

PRV

STORM DRAINAGE PIPING

ROOF DRAIN

---

PD

HWR

HW

PUMPED DISCHARGE

P-TRAP

HOT WATER PIPING

MG

G

ERL

CWV

HB/NFHB

H.C.

GV

MG

G

HANDICAPPED

GATE/BALL VALVE

GAS PIPING - LOW PRESSURE

FD

FCO

ERL

ERD

DN

CWV

FLOOR DRAIN

FLOOR CLEANOUT

PIPING TURNING DOWN

CD

CA

SYMBOL

COMPRESSED AIR

CONDENSATE DRAIN

CV

CD

B/F

B/G

CA

B/C

CHECK VALVE

BELOW COUNTER

BELOW GRADE

BELOW FLOOR

A/P

AFG

AFF

A/F

ABBREVIATION

A/C

AD

ACCESS PANEL

ABOVE FINISHED GRADE

ABOVE FINISHED FLOOR

ABOVE FLOOR

ABOVE CEILING

AREA DRAIN

DESCRIPTION

PLUMBING LEGEND

SA SHOCK ABSORBER

HOT WATER RETURN BALANCING VALVEBV

MINIMUM SIZE UTILITY TO FIXTURE

FIXTURE SCHEDULE

URINAL

WATER CLOSET - PUBLICWC-1/WC-1H

MOP SINKMS-1

URL-1/URL-1H

FIXTURE # FIXTURE TYPE

4"

3"

2"

1/2"

---

WASTECONNECTION

--- 1/2"

1/2"

3/4"

ELECTRIC WATER COOLEREWC-1 1-1/2" 1/2" 1/2"

3. ALL UNITS SHALL MEET ASHRAE 90.1-2007 AND ALL LOCAL CODE REQUIREMENTS.2. PROVIDE GATE/BALL VALVES WITH UNIONS AND DIELECTRIC FITTINGS ON WATER INLET AND OUTLET CONNECTIONS.

NOTES:

1. PROVIDE T&P RELIEF VALVE AND VACUUM RELIEF VALVE

WATER HEATER SCHEDULE

SYMBOL LOCATION/

GALLONS

STORAGECAPACITY REC./TEMP. RISE

GPHMODEL NO.

NOTESTEMPERATURE

OUTLETGAS CRITERIA

FLUESIZEINPUT

BTU

4. DESIGN BASIS: A. O. SMITH CUSTOM Xi SERIES

LAVATORY - PUBLICL-1/L-1H 1-1/4" 1/2" 1/2"

WHE-1 MECHANICAL 1525/ 61/100° 140°F 1-4----

LAVATORY - WALL-HUNGL-2H 1-1/4" 1/2" 1/2"

120

BREAK ROOM SINKBRS-1 1-1/2" 1/2" 1/2"

HOT WATERSUPPLY

COLD WATERSUPPLY

EMERGENCY EYEWASH (EW-1):WALL MOUNTED, STAINLESS STEEL BOWL. EYEWASH SHALL INCLUDE TWO SPRAY HEADS ONON SUPPLY ARMS. BASIS FOR DESIGN: GUARDIAN MODEL G1814.

S-1 1/2"MEETING ROOM SINK 1-1/2" 1/2" 1/2"

DSE-120

NOTES:

PUMP SCHEDULE

SYMBOL NOTESSERVICE/LOCATION

TYPE FLOW(GPM) (PSI/FT)

HEAD RPM HP

1. BASIS OF DESIGN: BELL & GOSSETT NBF-33.

1INLINEMECHANICAL 1525DOMESTIC HWR/HWRP-1 3.54/94.5 1725 1/8

TIME OF DAY OF TEST

UPON AWARD OF THE CONTRACT, THE FIRE PROTECTION CONTRACTOR

SHALL PERFORM A FLOW TEST ON THE TWO HYDRANTS NEAREST THE SITE

THE FOLLOWING WATER PRESSURE/FLOW DATA WAS OBTAINED FROM:

AND FORWARD THE TEST DATA TO THE ENGINEER AND ARCHITECT

FLOW TEST DATA SCHEDULE

62 PSI

55 PSI

N/A

1,100 GPM

RESIDUAL PRESSURE

STATIC PRESSURE

LOCATION OF TEST HYDRANT

ELEVATION OF TEST HYDRANT

DATE OF TEST

FLOW (GPM)

N/A

N/A

STATESBORO WATER DEPARTMENT

N/A

HS-1 LAB HAND SINK 1-1/2" 1/2" 1/2"

NOTES:

AIR COMPRESSOR SCHEDULE

SYMBOL

1

NOTESLOCATION TANK SIZE CAPACITY

120 GALLONSMECHANICAL 1525AC-1/2 24.1 SCFM AT 125 PSI

1. BASIS OF DESIGN: RECIPROCATING AIR COMPRESSOR, INGERSOLL RAND 2-2475E7.5-P TYPE 30.

*LISTED MANUFACTURERS ARE BASIS FOR DESIGN

OUTLET CONNECTION, CAST IRON DOME.BASIS FOR DESIGN: JAY R. SMITH FIG. 1080-Y C.I. BODY WITH 2" HIGH WATER DAM AND CAST IRON, NO HUBERD-EMERGENCY ROOF DRAIN

CONNECTION, CAST IRON DOME.CAST IRON, ADJUSTABLE EXTENSION TO SUIT INSULATION THICKNESS, NO HUB OUTLETBASIS FOR DESIGN: JAY R. SMITH FIG. 1015-Y-RC. C.I. BODY WITH FLASHING CLAMP AND SUMP RECEIVER CLAMP,RD-ROOF DRAINS-INSULATED ROOF

BASIS FOR DESIGN: JAY R. SMITH FIG. 1770, WALL MOUNTED CAST IRON BODY AND FLANGE, NICKEL BRONZE FINISHDOWNSPOUT NOZZLE

LAB HAND SINK(HS-1):WALL MOUNTED SINGLE BOWL LAB HAND SINK WITH DECK MOUNTED GOOSE NECK FAUCET,1-1/2" P-TRAP, & P-TRAP INSULATION KIT. BASIS FOR DESIGN: ADVANCE TABCO 7-PS-75

THERMAL EXPANSION TANKS

TAG

ELECTRICAL CRITERIA

INPUTKW

15

NOTES:

1. BASIS OF DESIGN: AMTROL. ACCEPTABLE MANUFACTURERS: WATTS, WESSELS

MANUFACTURER &MODEL NO.

ET-1 AMTROL MODEL# ST-12C

CONNECTION SIZE

¾" NPT

MAX WORKINGPRESSURE TANK VOLUME

ACCEPTANCEFACTOR

0.56.4 GAL150 PSIG

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17NOTES, LEGENDS, SCHEDULES

- PLUMBING

P-001Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

*DRAWINGLIST‐PLUMBING

SHEETNUMBER SHEETNAMEP-001 NOTES, LEGENDS, SCHEDULES - PLUMBINGP-002 DETAILS - PLUMBINGP-101 FLOOR PLAN - NORTH WING - PLUMBINGP-102 FLOOR PLAN - SOUTH WING - PLUMBINGP-103 ROOF PLAN - NORTH WING - PLUMBINGP-104 ROOF PLAN - SOUTH WING - PLUMBINGP-110 ENLARGED PLANS - PLUMBING

Page 2: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17DETAILS - PLUMBING

P-002Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

Page 3: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

DEMONSTRATION LAB

1516

LAB STRG. PARTNERS

1517

LAB STRG.

1518

COMPUTER LAB

1512

OFFICE

1513

OFFICE

1511

LAB

1514

VESTIBULE

1543

NORTH CORRIDOR

1540

LAB STRG

1515

LAB STRG 2

1510

LAB

1509

CLASSROOM

1504

CLASSROOM

1507

OFFICE

1508

CLASSROOM

1506

CLASSROOM

1503

OFFICE

1505

CLASSROOM

1501

MEETING ROOM

1502

LOBBY

1500

MEN'S RR

1519

WOMEN'S RR

1520

BREAK ROOM

1522

DATA

1521

ELEC.

1524

MECHANICAL

1525

OFFICE

1529

FAMILY RR

1523

VESTIBULE

1541

3" DOMESTICSERVICE B/F &UP. SEE CIVILFOR CONT.

6" FIRE SERVICEB/F & UP. SEECIVIL FOR CONT.

P-1102

P-1103

P-1101

4"SAN B/G @ 1.0%I.E. 5.00 BFF SEE CIVILFOR CONTINUATION

CA

SAN SAN

CA CA

4"4"

LAB (1516)/FUTURE USEUTILITY CONNECTIONS:4" SAN1¼" CW/HW (IF EMERGENCYSHOWER/EYEWASH REQUIRED)1" COMPRESSED AIRPROVIDE ¾"HB IN LAB

LAB (1514)/FUTURE USEUTILITY CONNECTIONS:4" SAN,1¼" CW/HW (IF EMERGENCYSHOWER/EYEWASH REQUIRED),1" COMPRESSED AIRPROVIDE ¾"HB IN LAB

LAB (1509)/FUTURE USEUTILITY CONNECTIONS:4" SAN1¼" CW/HW (IF EMERGENCYSHOWER/EYEWASH REQUIRED)1" COMPRESSED AIRPROVIDE ¾"HB IN LAB

SAN4"

CA

SA

N

4"

4"

3"

4"

3"

6"

4"

2"

¾"

SA

NC

A

1¼"

½"

CA

¾"

WCO

4"

SA

N

4"

IM-1

BRS-1

2"W DN2"V UP

½" HW &CW DN

EW-1

4"VTR

EW-1

2"W DN2"V UP

1/2"HW & CWW/ MIXINGVALVE

2"W DN2"V UP

½"HW & CWW/ MIXINGVALVE

S-12"W DN2"V UP

½" HW &CW DN

4"ST UP(1400 SF)

4"ST UP(1300 SF)6"ST DN(4300 SF)

6"ST B/G @ 1.0%I.E. 3.00 BFF SEE CIVILFOR CONTINUATION

4"ST UP(700 SF)

3"ST UP(600 SF)

4"ST B/G @ 1.0%I.E. 3.00 BFF SEE CIVILFOR CONTINUATION

4"ST UP(900 SF)

4"ST UP(1500 SF)

4"ST UP(1000 SF)

3"ST UP(600 SF)4"ST UP

(800 SF)

6"ST B/G @ 1.0%I.E. 3.00 BFF SEE CIVILFOR CONTINUATION

6"ST DN(4800 SF)

4"ST DN(1300 SF)

½"HW &CW DN

REFER TO ARCHITECTURE/INTERIOR DWGS FOR EXACTLOCATION OF HAND SINK

HS-1

½"HW & CW

REFER TOARCHITECTURE/INTERIOR DWGSFOR EXACTLOCATION OFHAND SINK

HS-1EW-1

2"W DN,2"V UP

½"HW & CWW/ MIXINGVALVE

½"HW & CW

REFER TOARCHITECTURE/INTERIOR DWGSFOR EXACTLOCATION OFHAND SINK

HS-1

4"EST UP(800 SF)

3"EST UP(600 SF) 4"EST UP

(1000 SF)

6"EST DN(4800 SF)

6"EST (4800 SF).DISCHARGE 12"AFF WITHDOWNSPOUT NOZZLE.

4"EST UP(1500 SF)

4"EST UP(900 SF)

4"EST UP(700 SF)

3"EST UP(600 SF)

4"EST DN(1300 SF)

4"EST (1300 SF).DISCHARGE 12"AFF WITHDOWNSPOUT NOZZLE.

4"EST UP(1400 SF)

4"EST UP(1300 SF)

6"EST DN(4300 SF)

6"EST (4300 SF).DISCHARGE 12"AFF WITHDOWNSPOUT NOZZLE.

NOTE:FINAL PROGRAM FOR LAB SPACES HAS NOT BEENFINALIZED. COORDINATE FINAL MEPREQUIREMENTS INCLUDING ITEMS SUCH ASEXHAUST FANS & COMPRESSED AIR CONNECTIONSWITH USER GROUP SELECTED TO UTILIZE SPACE.

4"

4"

4"

4"6"

6" 4"

4"

4"

4"

4" 6"

6"6"

3"

2"

3"

4"

4"4"2" 3" 4"

6" 6"

6"

½"

3"

2"

½"

1¼"

½"

¾"1¼" ¾"

1¼"

1¼" ¾" 1¼" ¾" 1¼" ¾"

1¼"

¾"

1¼"

¾"

2"

4"FD 'M'W/TP

4"

4"SAN

4"

3"W DN2"V UP3"HD

W/TP

HWRBALANCINGVALVE (2.5 GPM)

¾"

1½"

¾"

CA

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17FLOOR PLAN - NORTH WING -

PLUMBING

P-101

SCALE:NORTH 0 2 4 84 8 168 16 321 2 45 10 20

1/8" = 1'-0"1 FLOOR PLAN - NORTH WING - PLUMBING

Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

Page 4: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

LAB STRG 2

1510

BREAK ROOM

1522

DATA

1521

ELEC.

1524

MECHANICAL

1525

OFFICE

1529

FAMILY RR

1523

CUST.

1526

SOUTH CORRIDOR

1516

PLAN AND KEY ROOM

1527

MAIL ROOM

1531

OFFICE

1532

CUST.

1533

CONDITIONED AREA

1534

WET STRG

1538

DRY STRG

1539

VESTIBULE

1542

OFFICE

1536

WORKSHOP

1537

SHIPPING AND RECEIVING

1530

WORK ROOM

1528

OFFICE

1535

3" DOMESTICSERVICE B/F &UP. SEE CIVILFOR CONT.

6" FIRE SERVICEB/F & UP. SEECIVIL FOR CONT.

P-1103

P-1101

CA

4"

4"

3"

6"

SA

NC

AS

AN

1¼"

½"

CA

CA

3"

3"

4"

4"

4"

4"

4"FD 'M'W/TP

¾"

WORKSHOP (1537)UTILITY CONNECTIONS:4" SAN,1¼" CW/HW TO EMERGENCYSHOWER/EYEWASHAND HOSE REEL,1" COMPRESSED AIR

HB

3"FD 'M'W/TP

IM-1

BRS-1

3"W DN2"V UP

½" HW &CW DN

MS-1

2"W DN2"V UP

½" HW &CW DN

MS-1

EWC-1

2"W DN2"V UP

1/2"CW

IM-1

BRS-1

2"W DN2"V UP

1/2" HW& CW

4"ST UP(1100 SF)

4"ST UP(1700 SF)

4"ST UP(1600 SF)

6"ST B/G @ 1.0%I.E. 3.00 BFF SEE CIVILFOR CONTINUATION

6"ST DN(2800 SF)

NFWH

¾"CW DN

¾"CW DN

4"EST UP(1100 SF)

4"EST UP(1700 SF)

6"EST DN(2800 SF)

6"EST (2800 SF).DISCHARGE12"AFF WITHDOWNSPOUTNOZZLE.

4"EST UP(1600 SF)

4"EST UP(1400 SF)

3"

6"6"

4"4"

2"

½"

½"

½"

2"

½"

¾"

2"

¾"

¾"

½"

2"

2"

4" 4"

4"

6"

2"

3"

2"

3"

2"

3"

3"

6"

1¼"

¾"

2"

1¼"

¾"

1¼"

¾"

4"FD 'M'W/TP

4"FD 'M'W/TP

4"FD 'M'W/TP

4"

2"

4"

SANSAN

SAN4"

HWR BALANCINGVALVE (2.0 GPM)

¾"

½"

¾"

HWRBALANCINGVALVE (2.5 GPM)

HWRBALANCINGVALVE (1.0 GPM)

HWRBALANCINGVALVE (1.0 GPM)

¾"

1½"

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17FLOOR PLAN - SOUTH WING -

PLUMBING

P-102

SCALE:NORTH 0 2 4 84 8 168 16 321 2 45 10 20

1/8" = 1'-0"1 FLOOR PLAN - SOUTH WING - PLUMBING

Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

Page 5: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

4"RD(900 SF)

4"RD(1500 SF)

4"RD(1000 SF)

3"RD(600 SF)

4"RD(800 SF)

4"ERD(800 SF)

3"ERD(600 SF) 4"ERD

(1000 SF)

4"ERD(1500 SF)

4"ERD(900 SF)

4"RD(700 SF)

3"RD(600 SF)

4"ERD(700 SF)

3"ERD(600 SF)

4"RD(1400 SF)

4"RD(1300 SF)

4"ERD(1400 SF)

4"ERD(1300 SF)

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17ROOF PLAN - NORTH WING -

PLUMBING

P-103

SCALE:NORTH 0 2 4 84 8 168 16 321 2 45 10 20

1/8" = 1'-0"1 ROOF PLAN - NORTH WING - PLUMBING

Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

Page 6: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

4"RD(1400 SF)

4"ERD(1400 SF)

4"RD(1100 SF)

4"RD(1700 SF)

4"RD(1600 SF)

4"ERD(1100 SF)

4"ERD(1700 SF)

4"ERD(1600 SF)

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17ROOF PLAN - SOUTH WING -

PLUMBING

P-104

SCALE:NORTH 0 2 4 84 8 168 16 321 2 45 10 20

1/8" = 1'-0"1 ROOF PLAN - SOUTH WING - PLUMBING

Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE

Page 7: *DRAWING LIST PLUMBINGoatesplans.com/Archives/OTC Plant Operations Training/OTC...DRAINAGE PRODUCTS/SPECIALTIES FOR USE IN NON-PUBLIC AREAS. UNITS AS REQUIRED. BASIS FOR DESIGN: PPP

HWRP 1

TMV-1

WHE-1:1½" INLET/OUTLET,RUN T&P FULL SIZETO FLOOR DRAIN

3" DOMESTIC SERVICEB/F & UP W/ BACKFLOWPREVENTER INSTALLEDIN THE VERTICAL. SEECIVIL FOR CONT.

6" FIRE SERVICEB/F & UP W/ BACKFLOWPREVENTER INSTALLEDIN THE VERTICAL. SEECIVIL FOR CONT.

AIR COMPRESSORPUMPS (AC-1/2)

AIR COMPRESSORINTAKE

4"FD 'M'W/TP

COMPRESSED AIRLINE ROUTEDTO WORK SHOPAND LABS

¾"CW W/RPBP TOMECHANICAL MAKE-UPWATER CONNECTION. SEEMECH. DWGS FOR CONT.

3"

6"

6" FIRE LINETO BUILDINGSPRINKLER SYSTEM

4"FD 'M'W/TP

4"FD 'M'W/TP

1½"

2½"

4"

4"

4"

WC-1 WC-1 WC-1 WC-1

WC-1 WC-1 WC-1H

WC-1H

URL-1HURL-1

EWC-1

L-1 L-1H

L-1 L-1H

WC-1/WC-1H: 4"S,2"V, 1"CW

¾"CW A/C & DNIN WALL. EXTEND½"CW/HW TOEACH LAV.

2"CW A/C & DNIN CHASE TO2" HEADER. EXTEND1"CW TO EACH WC.

URL-1/URL-1H: 2"S,2"V, ¾"CW

L-1/L-1H: 2"W,2"V, ½"CW/HW

2"W DN,2"V UP (TYP.)

EWC-1: 2"W,2"V, ½"CW

2"

¾"¾"

2"

½"

4"SAN DN,2"V UP (TYP.)

4"

2"W DN,2"V UP (TYP.)

4"4"4"

L-1

L-1

3"FD"G"W/TP

3"FD"G"W/TP

3"

3"

WC-1H

L-2H

L-2H: 2"W,2"V, ½"CW/HW

1¼"

½"

WC-1/WC-1H: 4"S,2"V, 1"CW

2"W DN,2"V UP (TYP.)

4"SAN DN,2"V UP (TYP.)

1"

4"

3"FD"G"W/TP

THIS DRAWING IS THE EXCLUSIVE PROPERTY OF THE ARCHITECTSAND MAY NOT BE REPRODUCED OR USE WITHOUT THEIR WRITTEN

AUTHORIZATION AND PERMISSION.COPYRIGHT © 2016 COLLINS COOPER CARUSI ARCHITECTS, INC.

/Vol

umes

/CC

CA

-dat

a/P

roje

cts/

2016

/160

02.0

0 -

Oge

eche

e P

lant

Ope

ratio

ns &

Wor

kfor

ce T

rain

ing

Cen

ter/

Des

ign/

Arc

hiC

ad/1

6112

7-O

geec

hee

Tec

h .p

ln -

11/1

4/16

SHEET TITLE

RELEASED FOR CONSTRUCTION

OGEECHEE TECHNICAL COLLEGE

PLANT OPERATIONS AND WORKFORCE

TRAINING CENTER

TCSG-330

One Joseph E. Kennedy BlvdStatesboro, GA 30458

Project Number : 16002.00REVISION/SUBMISSION

SD SUBMITTAL - 11.28.16

DD SUBMITTAL - 01.11.17

CD SUBMITTAL - 03.22.17

DRG RESPONSES - 05.04.17

DRG RESPONSES - 06.16.17

ISSUE FOR BID - 07.17.17ENLARGED PLANS - PLUMBING

P-110

SCALE:0 2 4 84 8 168 16 321 2 45 10 20

1/4" = 1'-0"1 ENLARGED MECHANICAL ROOM (1525) - PLUMBING

SCALE:0 2 4 84 8 168 16 321 2 45 10 20

1/4" = 1'-0"2 ENLARGED MEN'S RR (1519)/WOMEN'S RR (1520) - PLUMBING

SCALE:0 2 4 84 8 168 16 321 2 45 10 20

1/4" = 1'-0"3 ENLARGED FAMILY RR (1523) - PLUMBING

Project Number -

Drawn By - Checked By -

Jordan & SkalaEngineers

6069 South Ft. Apache Rd., ● Suite 100Las Vegas, NV 89148

p. 702.362.5111 ● f. 702.362.5554

1610287DA EE