DRAINAGE IMPACT ASSESSMENT
Transcript of DRAINAGE IMPACT ASSESSMENT
![Page 1: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/1.jpg)
Tridax Ltd Version 1.0
DRAINAGE IMPACT ASSESSMENT
for
Proposed Residential Development at
‘Old Rectory Court’ The High Street
Burwash Etchingham East Sussex
TN19 7EW
on behalf of
MH Architects
![Page 2: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/2.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 2 July 2017
Document Control Sheet
Project Title Proposed Residential Development
Demolition and redevelopment of ‘Old Rectory Court’ to provide
residential accommodation with associated parking and refuse/bin
stores
Document Title Drainage Impact Assessment
Job No. EMC-2017-129
Revision 1.0
Status Draft – Issue to LPA
Issue Status Author Date Check Date Authorised Date
1.0 Draft S. Carr 19.07.17 P. Lavender 19.07.17
Distribution List
Version Issued to Purpose Date
1.0 MH Architects (via email) 1st Draft 19.07.17
![Page 3: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/3.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 3 July 2017
CONTENTS
1.0 Status………….…………………………………….. 4
2.0 Introduction………………………….……………....
Background………………………………………….
Site Location…………………………………………
Existing Site Layout…………………………………
Proposed Development…………………………….
5
5
5
6
8
3.0 Foul Water Drainage……………………………......
Existing Discharge…...……………………………...
Proposed Discharge……………….……………….
Consents……………………………………………..
12
12
13
13
4.0 Surface Water Drainage……….………………......
Existing Discharge…...……………………………...
Proposed Discharge……………….……………….
Consents……………………………………………..
15
15
16
16
5.0
6.0
Flood Risk………………........................................
Conclusions…………………………………………
17
18
Appendix A Tridax Drawings EMC-2017-129-01 – Site Location EMC-2017-129-02 – Existing Site Drainage EMC-2017-129-03 – Outline Drainage Strategy
Appendix B Calculations Greenfield Runoff Quick Storage Calculation
Appendix C Correspondence
![Page 4: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/4.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 4 July 2017
1.0 STATUS
1.1 This Report is prepared for the sole use of MH Architects and their agents in
connection with the proposed forthcoming planning application. No responsibility
can be assumed for the Report if used by others.
1.2 For the purposes of the Contracts (Rights of Third Parties) Act 1999, nothing in
this Report shall confer on any third party any right to enforce or benefit from any
term of this Report
![Page 5: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/5.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 5 July 2017
2.0 INTRODUCTION
Background
2.1 Tridax Ltd have been commissioned by MH Architects on behalf of Amicus
Horizon (Optivo) and requested to prepare a Drainage Impact Assessment for
the proposed demolition and redevelopment of ‘Old Rectory Court’, High Street,
Burwash, Etchingham to provide residential accommodation consisting of 4 two
bed houses and 15 flats with associated car parking.
2.2 This Report is in accordance with the requirements of the Technical Guidance to
the National Planning Policy Framework (NPPF).
2.3 The Report details the observations, calculates the probable flows that may be
generated by the development and makes recommendations for the disposal of
the foul and surface water.
2.4 Discussions have previously been undertaken with the Local Authority Planning
department and a copy of correspondence received 11 December 2015 is
included in Appendix C. This report seeks to address the issues raised in respect
to the disposal of foul and surface water drainage.
Site Location
2.5 The development is located adjacent to the The High Street (A265), as indicated
on the extract as Frames 1 and 2 below. The total site area is approximately
2,480m² and is centred at Ordnance Survey reference (567521mE, 124700mN)
on sheet TQ675247. The site boundary is shown edged red.
![Page 6: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/6.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 6 July 2017
Frame 1 – Site Location Plan Extract
Frame 2 – Existing Site Layout Plan
Existing Site Layout
2.6 The location of the proposed development is a ‘Brownfield’ site that is currently
occupied with residential buildings known as ‘Old Rectory Court’. Approximately
1190m2 of site is composed of impermeable surface finishes. The site is
currently laid out as twenty-three 1-bed flats. Extracts of the public sewer records
are shown as frame 3 below.
![Page 7: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/7.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 7 July 2017
Frame 3 – Existing Site Drainage
2.7 Inspection of the sewer records indicates that there is a 175mmØ public foul
water located in the highway to the front of the existing property (High Street)
which is approximately 3m deep. There is also a 100mmØ public foul sewer
located to the rear of the site but no details are currently available. There are no
surface water sewers identified in close proximity to this site. There may be
other private drainage crossing this site that will require abandoning in order to
carry out the construction work. A survey will be required to confirm the current
on-site drainage arrangements. An application will be required under Section
106 of the Water Industry Act 1991 for the connecting the new developments
drainage to the public sewer.
2.8 Inspection of the British Geological Survey map for this area indicates the site to
be underlain with a bedrock geology of either Wadhurst Clay Formation,
consisting of Mudstone, or Tunbridge Wells Sand Formation, consisting of
Sandstone. A Ground investigation will be required on site to confirm the
geology.
![Page 8: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/8.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 8 July 2017
Proposed Development
2.9 The proposed development comprises the demolition of the existing property,
‘Old Rectory Court’, and the construction of fifteen No 1-bed flats and four No 2-
bed houses with associated car parking. Refer to the Architects planning
drawings and the extract of the proposed site plan as Frames 4, 5, 6, 7, 8 and 9
below.
Frame 4 – Proposed Site Location Plan
![Page 9: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/9.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 9 July 2017
Frame 5 – Proposed Ground Floor Plan - Housing Block
Frame 6 – Proposed First Floor Plan - Housing Block
![Page 10: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/10.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 10 July 2017
Frame 7 – Proposed Lower Ground Floor Plan – Flats
Frame 8 – Proposed Upper Ground Floor Plan – Flats
![Page 11: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/11.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 11 July 2017
Frame 9 – Proposed First Floor Plan – Flats
![Page 12: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/12.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 12 July 2017
3.0 FOUL WATER DRAINAGE
Existing Discharge
3.1 ‘Old Rectory Court’ is currently laid out as eighteen 1-bed flats. Assuming each
flat has a kitchen sink, washing machine, bath, wc and washbasin a conservative
existing peak discharge in order of 6.4 litres/second could be expected
(Q=(0.7)kDU√(∑(DU)).
Peak Flow Rates to BS EN 752: Part 4
kDU frequency factor (0.7 for dwellings)
Sanitary No of DU ∑DU Appliance Features Existing WC's 1 x 18 1.20 21.6 Roselands Washbasin 1 x 18 0.30 5.4 Bath 1 x 18 0.80 14.4
Kitchen Sink 1 x 18 0.80 14.4
Washing Machine 1 x 18 1.50 27.0
(Q=(0.7)kDU√(∑(DU)) 82.8 Q= 6.4 l/s
3.2 The roof water from the existing buildings, hardstanding areas and path
(1190m²) are assumed to be disposed of via infiltration techniques within the site
such as soakaways although this is yet to be confirmed. In order to determine
potential impacts upon the public system it is considered that some or all of this
surface water runoff may actually have been combined with the sites foul
drainage system and connected to the foul water sewer. Enclosed within
Appendix B are the results from MicroDrainage Windes indicating the following
peak discharges;
1 year return ~ 2.1 l/s
30 year return ~ 4.6 l/s
100 year return ~ 5.7 l/s
3.3 The existing peak discharge to the foul water sewer is assumed to be
6.4litres/second which could rise to approximately 11.0 litres/second taking
into account a 30 year return period should it be confirmed that surface water
runoff combines with the foul drainage system from this site.
![Page 13: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/13.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 13 July 2017
Proposed Discharge
3.4 The proposed peak foul water discharge from the residential development
calculated in accordance with BS EN 752: Part 4 is 4.9 litres/second, as per
the table below;
Peak Flow Rates to BS EN 752: Part 4
kDU frequency factor (0.5 for dwellings)
Sanitary No of DU ∑DU Appliance Features Block A WC's 2 x 4 1.20 9.6 4 No Houses Washbasin 2 x 4 0.30 2.4 Bath 1 x 4 0.80 3.2
Kitchen Sink 1 x 4 0.80 3.2
Washing Machine 1 x 4 1.50 6.0
Block B WC's 1 x 15 1.20 18.0
15 No Flats Washbasin 1 x 15 0.30 4.5
Showers 1 x 15 0.30 4.5
Kitchen Sink 1 x 15 0.80 12.0
Washing Machine 1 x 15 1.50 22.5
Q=kDU√(∑DU)
85.9 Q= 4.63 l/s
3.5 The design flow from the proposed development using ‘sewers for adoption’ 7th
Edition is calculated as 0.97 litres/second as below;
6DWF = 4,000 litres/dwelling/day x 19No Dwellings = 0.88 l/s
24hours
3.6 The replacement development will result in a reduction of the foul flow being
generated and discharged to the public foul drainage of 1.77 litres/second (6.4 -
4.63l/s). If it is determined that surface water does actually currently discharge to
the public system, then its potential disconnection from the foul water sewer will
create a spare peak discharge capacity of 4.6/s. An indicative foul water
drainage plan is shown on the drainage strategy drawing EMC-2017-129-03 is
enclosed within Appendix A.
Consents
3.7 A Section 106 Water Industry Act application to connect to the public foul water
sewer will be required to be made to and approved by Southern Water Services.
![Page 14: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/14.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 14 July 2017
3.8 Southern Water’s letter of 6 November 2015 (Ref Plan-011498) states that there
is inadequate capacity available within the public foul drainage system to provide
additional foul sewage disposal service to a proposed development. As the new
development represents a reduction in foul flows entering the public foul system
this will increase available capacity within the public system and there is no
requirement to submit a formal application for a capacity check to Southern
Water Authority. However, Southern Water have requested that should an
application receive planning approval then the following condition is attached to
the consent: ‘Construction of the development shall not commence until details
of the proposed means of foul and surface water sewerage disposal have been
submitted to, and approved in writing by, the Local Planning Authority (LPA) in
consultation with Southern Water.’ A detailed foul and surface water drainage
design will need to be submitted to the LPA for approval to discharge such a
planning condition.
![Page 15: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/15.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 15 July 2017
4.0 SURFACE WATER DRAINAGE
Existing Discharge
4.1 The requirement of NPPF is that the run-off from the development proposals
replicates the natural drainage characteristics of the pre-developed site. In the
case of ‘Brownfield’ development, the drainage proposal will be measured against
the existing performance of the site, although it is preferable for solutions to
provide characteristics similar to ‘Greenfield’ development wherever possible.
4.2 The existing site characteristics are summarised as below;
Total Site Area 0.248 hectares
Current Site Condition Brownfield
Existing Impermeable Area 1,190m²
Proposed Impermeable Area 1,430m²
Existing Surface Water Potentially 1190m² to surface water Discharge Method run-off to foul sewer TBC (Section 3.0)
4.3 Enclosed within Appendix B are the results from Micro Drainage Windes for the
existing surface water system of the existing site indicating the following peak
discharges;
1 year return ~ 2.1 l/s
30 year return ~ 4.6 l/s
100 year return ~ 5.7 l/s
![Page 16: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/16.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 16 July 2017
Proposed Discharge
4.4 Considering the underlying geology of the site Tunbridge Wells Sand
Formation, it is possible that the use of on-site filtration may be appropriate. This
will be subject to completion of a Geotechnical Investigation which will need to
confirm the ground water table level and sub-strata details with ground infiltration
rates provided to enable the design of suitable infiltration techniques. If found to
be Wadhurst Clay Formation, it is highly unlikely that infiltration techniques will
be an acceptable method for surface water disposal. There are no public surface
water sewers identified in close proximity to this site. There are however two
public foul sewers adjacent the site which are only small bore pipes (175mm and
100mm Ø) so it is unlikely that these will have been designed to accept surface
water discharge although it may be that there is some surface water that is
connected without permission. It is unlikely that an alternative solution to
attenuated surface water storage system with controlled discharge will be
permitted by Southern Water to connect to the public foul water sewer. Due to the
lack of public surface water sewers at this location together with the high volume
of properties discharging surface water runoff it is assumed that infiltration
techniques do currently work at this location although this will require confirming
by further ground investigations as mentioned above.
4.5 An outline drainage strategy drawing EMC-2017-129-03 is enclosed within
Appendix A
Consents
4.6 A detailed foul and surface water drainage design will need to be submitted to the
LPA for approval to discharge any relevant planning condition prior to
commencing work on site. The responsibility of the management and
maintenance will need to meet the requirements of the Flood and Water
Management Act, however it is currently unclear when the Adopting SUDS
Authority will be empowered (East Sussex County Council). Until such time the
responsibility for any storage structure and/or flow control device will remain with
the property owners.
![Page 17: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/17.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 17 July 2017
5.0 FLOOD RISK
5.1 Inspection of the Environment Agency Website identifies the proposed site to be
within the extent of the Flood Zone 1 (Low Probability). This zone comprises
land assessed as having a less than 1in1000 annual probability of river or sea
flooding (<0.1%). All uses of land are appropriate within this zone. Refer to
Frame 10 below.
Frame 10 - Extract of Environment Agency Flood Map
5.2 Reference to Table 1 of the NPPF states the policy aim to reduce the overall
level of flood risk by the appropriate application of sustainable drainage systems.
As the proposed site is below one hectare in size, no separate flood risk
assessment is required.
![Page 18: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/18.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 18 July 2017
6.0 CONCLUSION
6.1 Tridax Ltd have been commissioned by MH Architects on behalf of Amicus
Horizon (Optivo) and requested to prepare a Drainage Impact Assessment for the
proposed Residential Development on the former ‘Old Rectory Court’ site at The
High Street, Burwash, Etchingham, East Sussex.
6.2 The new development will reduce the quantity of foul water being discharged to
the public foul water sewer from 6.4l/s to 4.63l/s therefore creating additional
available capacity of 1.77l/s within the public foul water sewer.
6.3 Should it be confirmed that the existing buildings surface water runoff does enter
the foul drainage system, then the potential disconnection from the foul water
sewer and disposal via infiltration techniques within the development site will
create a spare peak discharge capacity of 4.6l/s within public foul water sewer.
6.4 The intention for the disposal of the surface water runoff from the new
development will be to discharge within the development site via suitable SUDs
infiltration techniques.
6.5 A Section 106 Agreement will be required with Southern Water Authority for
connections to the public foul sewer.
6.6 An outline drainage strategy drawing EMC-2017-129-03 is enclosed within
Appendix A
6.7 The site is indicated to be within the extent of the Flood Zone 1 (Low Probability).
This zone comprises land assessed as having a less than 1in1000 annual
probability of river or sea flooding (<0.1%). All uses of land are appropriate within
this zone
6.8 In accordance with the requirements of the Technical Guidance to the National
Planning Policy Framework (NPPF), we conclude that the site can be adequately
drained and is not at risk from flooding or increases the risk of flooding elsewhere.
![Page 19: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/19.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 19 July 2017
APPENDIX A
Tridax Drawings EMC-2017-129-01 – Site Location EMC-2017-129-02 – Existing Site Drainage EMC-2017-129-03 – Proposed Drainage Strategy
![Page 20: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/20.jpg)
![Page 21: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/21.jpg)
![Page 22: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/22.jpg)
![Page 23: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/23.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 20 July 2017
APPENDIX B
Calculations Greenfield Runoff Quick Storage Calculation
![Page 24: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/24.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 21 July 2017
![Page 25: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/25.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 22 July 2017
![Page 26: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/26.jpg)
Tridax Ltd Version 1.0
Job No. EMC-2017-129 23 July 2017
APPENDIX C
Correspondence
![Page 27: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/27.jpg)
![Page 28: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/28.jpg)
![Page 29: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/29.jpg)
![Page 30: DRAINAGE IMPACT ASSESSMENT](https://reader031.fdocuments.in/reader031/viewer/2022012413/616d71943de38018006d7c84/html5/thumbnails/30.jpg)