D Draeger Safety DSI Training ©2002 July 11, 2008 Page 1 Draeger-Tubes® Draeger-Tube® and Pump Training Program

Transcript of Draeger-Tube® and Pump Training Program · Draeger Safety D DSI Training ©2002 July 11, 2008 Page...

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 1 Draeger-Tubes®

Draeger-Tube® and PumpTraining Program

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 2 Draeger-Tubes®

DisclaimerThis visual presentation is intended to help theuser understand and correctly use theDraeger-Tube & Pump System It is not intendedto substitute for any sp ecific instruction sheetsprovided with the tubes and the pump.

IT IS THE USER’S RESPONSIBILITY TOREAD AND UNDERSTAND ALL MANUALSAND INFORMATION PROVIDED WITH THETUBES AND THE PUMP!Pictures may not represent actual applicationscenarios, but are merely provided for illustrationpurposes.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 3 Draeger-Tubes®

What are Dräger-Tubes?Dräger tubes are glasstubes filled with achemical indicator.The chemical indicator isdesigned to produce acolor change when an airsample containing thatspecific substance orsubstances are pulledthrough the tube. Examples of

tube types

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 4 Draeger-Tubes®

Parts of the Tube

Dräger

Water Vapor 1/b

n=

2

15

10

5

3

1

Airflow directional arrow

Tube nomenclature indicates gas to be measured

Determine reading using the length of color stain

Number of pump strokesBatch: ARHM - 0111

(Aim towards pump inlet)

Quality control batch number

8101781

Part number

Hermetically-sealed glass tube housing

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 5 Draeger-Tubes®

What is a Dräger accuro Pump?The Dräger accuro pumpis the device used todraw a calibrated 100 mlof air sample through theDräger-Tube.

Draeger accuro pump

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 6 Draeger-Tubes®

Parts of the Pump

Ceramic TubeOpener

Counter ResetButton

End-of-StrokeIndicator

Pump Inlet Socket

Stroke Counter

Metal Tip Breaker

Wrist Strap

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 7 Draeger-Tubes®

Taking a Measurement

Reset the counter on the pump to zero bydepressing the reset button using a penor unbroken tube.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 8 Draeger-Tubes®

Taking a Measurement

Break the tips of the detector tube.Deluxe Tube Opener Cutter on Pump

1 Twist to score2 Push to clip tip

Scrape to score Bend against cutter to break

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 9 Draeger-Tubes®

Taking a Measurement

Break the tips of the detector tube.Metal Tip Breaker

Insert the tube tip and bend to break each tip.CAUTION: The metal tip breaker will cause jagged glass tips

Metal TipBreaker

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 10 Draeger-Tubes®

Insert the tube into the pump inlet withthe arrow pointing toward the pump.

Taking a Measurement

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 11 Draeger-Tubes®

Grip the pump according to the photo.Compress the bellows completely (strokecounter will advance), then release yourgrip; the air sample begins to be pulled through the tube.

Taking a Measurement

End of stroke indicatoris dark when pump isunder vacuum.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 12 Draeger-Tubes®

Wait for the end ofstroke indicator topop up (white).

Signifies completion ofthe stroke

Take the requirednumber of strokesaccording to theinstructions

The time per stroke willvary based on thespecific tube used

Taking a Measurement

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 13 Draeger-Tubes®

Remove the tube from thepump at the end of the laststroke and read the tubeimmediately (unless theinstructions specify otherwise)

Taking a Measurement

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 14 Draeger-Tubes®

Reading Draeger-Tubes

Read the total length ofthe discoloration

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 15 Draeger-Tubes®

Reading Draeger-Tubes

If the discolorationbecomes progressivelylighter, read to thepoint where the faintestdiscoloration is justvisible.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 16 Draeger-Tubes®

Reading Draeger-Tubes

If the indication is adistinct diagonal acrossthe length of the tube,read to the midpoint.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 17 Draeger-Tubes®

Tips for Reading Draeger-Tubes

Adequate lighting - no direct sunlightHold tube against light coloredbackgroundCompare with an unused tube

Using a light background like a white sheetof paper and comparing with an unused tubewill enhance the color distinction

ppm

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 18 Draeger-Tubes®

Operating InstructionsDraeger-Tube HandbookDraeger VOICE

DO NOT assume that the measuring range is linear forall sample volumes!

Extending the Measurement Range

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 19 Draeger-Tubes®

W A R N I N G !!Draeger detector tubes and gas detection pumpsare designed and calibrated as a unit.

Interchanging Dräger pumps and tubes with othermanufacturer’s products is not recommended norpermitted according to OSHA regulations

The American National Standard for gas detectortube units, ANSI/ISEA 102-1990, “Short Term Typefor Toxic Gases and Vapors in WorkingEnvironments” was reaffirmed for five years onNovember 3, 1998. The new reference for thestandard is ANSI/ISEA 102-1990 (R1998).

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 20 Draeger-Tubes®

Short-term Tube Nomenclature

Acetone 100/b (100 - 12,000 ppm)Calibrated gas / vapor to be detected

This tube is calibrated for acetoneOther ketones (MEK, MIBK) are alsoindicated, but the sensitivity may differrequiring a correction factor

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 21 Draeger-Tubes®

Short-term Tube Nomenclature

Acetone 100/b (100 - 12,000 ppm)Typically indicates the first scale mark orlowest concentration for the standardrange

Information to extend the range to measurehigher or lower concentrations may befound in the instructions, the handbook, orVOICE

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 22 Draeger-Tubes®

Short-term Tube Nomenclature

Acetone 100 /b (100 - 12,000 ppm)Indicates the latest revision to enhancethe properties of the tube

The letter designation is typically lowercaseLower case: 5” tubesUpper case: 8” tubes

– e.g. Hydrogen Sulfide 0.2%/A

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 23 Draeger-Tubes®

Short-term Tube Nomenclature

Acetone 100/b (100 - 12,000 ppm)Specifies standard measuring range

Generally in units of ppmOther units for various gases or vapors:

– Vol.%, mg/m3, mg/L, lbs/mmcf

Tubes calibrated in Vol.% are an exceptionand show “%” in the name

– e.g. Oxygen 5%/C

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 24 Draeger-Tubes®

Information on Front of Box

Part NumberBatch / Lot NumberTotal Number of Tests(10, 9, 8, 5)Measuring RangeISO 9001

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 25 Draeger-Tubes®

Information on Back of Box

Storage Temperature (25 °C / 77 °F)Keep tubes below 77° F, but donot freeze!

Expiration DateDo not use expired tubes fortesting!Shelf life of most Draeger-Tubes is24 months

JUL 04U.S.A.

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 26 Draeger-Tubes®

Draeger SupportVOICE™ database software

VOICE 4.0, now on Draeger.net

Draeger-Tubes / CMS Handbook

Detector Tube Catalogs

Technical Product Data

Training CDs

DDraegerSafety

Pump & TubeTraining CD

DSI Training ©2001Rev: 0

DDraeger Safety

DSI Training ©2002July 11, 2008 Page 27 Draeger-Tubes®

Additional Questions?Draeger is always happy toassist you with any additionalquestions you have regardinguse of Draeger-Tubes®.Please call us toll free:800/922-5518 in the USA877/372-4371 in CanadaTo contact us online: