www.itmikro.com Technical Data DPM DISPLAY TYPE LCD display MEASUREMENTS 3-phase 4-wire system 3-phase 3-wire system CT primary : 5 ~ 9995 A CT secondary : 5 A Minimum measurement : 5 mA Accuracy : 0.5% from 1A to 6 A (secondary) Burden : < 0.05 VA at 5 A Sustained overload : 6 A Nominal phase voltage : 20 ~ 300 V AC Minimum measurement :10 V Accuracy : 0.5% at full scale Phase voltage via VT : 60 ~ 33,000 V POWER MEASUREMENT power measurement : 1 s Accuracy : 1.0% POWER DEMAND Interval : 1 ~ 30 mins POWER FACTOR MEASUREMENT Total and displacement power factor Accuracy : 1.0% FREQUENCY MEASUREMENT Measurement range : 45 ~ 65 Hz : 1s Accuracy : 0.5% ENERGY ACCURACY : class 1 : class 2 AUXILIARY POWER SUPPLY AC voltage : 90 ~ 415 V AC Frequency : 50 / 60 Hz DC voltage : 100 ~ 300 V DC : <3 VA COMMUNICATION Hardware interface : Isolated RS485 Protocol : Modbus-RTU Baud rate : 2400, 4800, 9600, 19200, 38400 ENVIRONMENTAL CONDITIONS Temperature : -10°C to 55°C Humidity : 5% to 95%, non-condensing MECHANICAL : P Dimension (mm) : 96(w) x 96(h) x 105(d) Approximate weight : 0.48kg : IP54 at the panel IP20 at the body 380 Features MEASUREMENT PARAMETERS: • Phase Voltage (L-N) & Line Voltage (L-L) • Min & Max Phase and Line Voltage • Phase Current and Neutral Current • Min & Max Phase Current and Neutral Current • kVA (per phase & total) • Min & Max kW, kVAR and KVA • Frequency • True & Displacement Power Factor (per phase & total) • Energy kWh, kVARh and kVAh • THD Phase Voltage ( L-N ) • THD Phase Current • Power Demand (kW, kVAR & kVA) • Maximum Power Demand (kW, kVAR & kVA) Digital Power Meter DPM 380

Transcript of dpm380 - itmikro.com · Electromagnetic Compatibility (EMC) Ordering Information Part 6-2: Generic...

Page 1: dpm380 - itmikro.com ·  Electromagnetic Compatibility (EMC) Ordering Information Part 6-2: Generic Standards IEC61000-6-2 Immunity for industrial environments.

w w w . i t m i k r o . c o m

Technical Data

DPM

DISPLAY TYPELCD display

MEASUREMENTS3-phase 4-wire system3-phase 3-wire system

CT primary : 5 ~ 9995 ACT secondary : 5 AMinimum measurement : 5 mAAccuracy : 0.5% from 1A to 6 A (secondary)Burden : < 0.05 VA at 5 ASustained overload : 6 A

Nominal phase voltage : 20 ~ 300 V ACMinimum measurement :10 VAccuracy : 0.5% at full scalePhase voltage via VT : 60 ~ 33,000 V

POWER MEASUREMENT

powermeasurement

: 1 sAccuracy : 1.0%

POWER DEMANDInterval : 1 ~ 30 mins

POWER FACTOR MEASUREMENTTotal and displacement power factorAccuracy : 1.0%

FREQUENCY MEASUREMENTMeasurement range : 45 ~ 65 Hz

: 1sAccuracy : 0.5%

ENERGY ACCURACY : class 1

: class 2

AUXILIARY POWER SUPPLYAC voltage : 90 ~ 415 V ACFrequency : 50 / 60 HzDC voltage : 100 ~ 300 V DC

: <3 VA

COMMUNICATIONHardware interface : Isolated RS485Protocol : Modbus-RTUBaud rate : 2400, 4800, 9600, 19200, 38400

ENVIRONMENTAL CONDITIONSTemperature : -10°C to 55°CHumidity : 5% to 95%, non-condensing

MECHANICAL : P

Dimension (mm) : 96(w) x 96(h) x 105(d)Approximate weight : 0.48kg

: IP54 at the panel IP20 at the body

380Features

MEASUREMENT PARAMETERS:• Phase Voltage (L-N) & Line Voltage (L-L)• Min & Max Phase and Line Voltage• Phase Current and Neutral Current• Min & Max Phase Current and Neutral Current

• kVA (per phase & total)• Min & Max kW, kVAR and KVA• Frequency• True & Displacement Power Factor (per phase & total)• Energy kWh, kVARh and kVAh• THD Phase Voltage ( L-N )• THD Phase Current• Power Demand (kW, kVAR & kVA) • Maximum Power Demand (kW, kVAR & kVA)

Digital P

ower M

eterD

PM

380

Page 2: dpm380 - itmikro.com ·  Electromagnetic Compatibility (EMC) Ordering Information Part 6-2: Generic Standards IEC61000-6-2 Immunity for industrial environments.

w w w . i t m i k r o . c o m

Electromagnetic Compatibility (EMC)

Ordering Information

Part 6-2: Generic Standards IEC61000-6-2Immunity for industrial environments.

Part 6-4: Generic Standards IEC61000-6-4Emission standard for industrial environments.

MODEL DESCRIPTION

DPM 380-415AD Auxiliary Voltage 90 ~ 415 V AC or 100 ~ 300 V DC, with RS 485

Typical Application Diagram Case Dimensions

Cut-Out Recommendations

Digital P

ower M

eterD

PM

380

3-PHASE 4-WIRE SYSTEM:4CTs, direct V input. 3-PHASE 4-WIRE SYSTEM:3CTs, direct V input.

3-PHASE 3-WIRE SYSTEM:3CTs, 3VTs 3-PHASE 3-WIRE SYSTEM:2CTs, 3VTs

Front

Rear

Back

1 2 3 4 5 6 7 8

9 10 11 12 13 1415 16 17 18 19 20

19

201234

567

8

15

16

17

18

14

13

12

19

201234

567

8

15

16

17

18

14

13

12

19

201234

56

7

8

15

16

17

18

14

13

12

19

201234

56

78

15

16

17

18

14

13

12