1
ANACONDA SEALTITE
MULTIFLEX, LIQUIDTITE, SEALTITE,HIPROJACKET, THERMOJACKET,
ANA-QUICK
ANACONDA SEALTITE
MULTIFLEX, LIQUIDTITE, SEALTITE,HIPROJACKET, THERMOJACKET,
ANA-QUICK
CONDUIT SYSTEMS FOR
ELECTRICAL WIRING
CONDUIT SYSTEMS FOR
ELECTRICAL WIRING
-
7/27/2019 Download Electrical Catalogue
2/72
2
COMPANY PROFILE.
Anamet Europe BV is a specialist in the field of flexible connectionand protection systems. As a part of Anamet Inc., we can supportcustomers with our specialism all over the world.
We offer our customers solutions to questions of connecting andprotecting cables, pipes and hoses.
In the product range you will find, in addition to the respected
Anaconda Sealtite conduits, new metal conduits Anamet Liquidtite,Multiflex and Multitite for less demanding applications.
Anamet can also provide custom designed products to meet specificcustomer requirements. Anamet also offers metal hoses for the
transport of liquids and gases together with accessory items forthermal insulation and fastening.
QUALITY ASSURANCE POLICY.
Through the implementation of our ISO 9001 quality assurance system,
there is an integral system that ensures that our products meet yourdemands and that our internal processes and services are being
improved continuously, in order to fulfil your expectations in the bestpossible way.
Which conduit-system is the best applicable for you, will depend onthe demands you make on flexibility, durability, external parameters
(temperature, chemical resistance, etc.) and the degree of mechanicalprotection.
These factors will guide you to the choice for a specific system. Inorder to help you better with your choice, our conduit systems are
being classified according to EN 50086.
With the help of this standard, you can easily determine which conduitsystem fulfils your minimum requirements.
The right choice is of great importance for the continuity of yourprocesses!
New prod uc ts in th is ca ta logue are :
Pag. 9 and 10 The S.L. & S.L.B. conduits based on the Anaconda Sealtite concept.
Pag. 12 and 13 Anaconda fittings for S.L. & S.L.B. conduits.
Pag. 14 and 15 RWS conduit, a robust conduit and fittings with UL approval.
Pag. 18 and 19 Anaconda fittings for U.I. conduit
Pag. 25 and 26 Anaconda Sealtite conduit type EF and OR in leadfree execution.
Pag. 34 till 39 The complete series Anaconda fittings in all their executions and variations.
Pag. 48 and 49 Anaconda Sealtite H.C.I. and H.F.I., conduits with a stainless steel innercore.
Pag. 50 and 51 Anaconda stainless steel fittings for Anaconda Sealtite conduits.
Pag. 54 and 55 NMUA conduit, a full plastic conduit with UL/CSA approval and fittings.
-
7/27/2019 Download Electrical Catalogue
3/72
3
1.
2.
3.
4.
5.
6.
CONTENT page
Introduction: company profile & quality assurance policy 2Product-choice table 4 - 5Explanation of EN 50086 6Installation instruction Anaconda conduit and fittings 7Explanation Anaconda fittings 8
ANACONDA MULTIFLEX
Metal conduits (square-locked) without a cover: S.L., S.L.B. & S.L.I. 9 - 11Fittings for S.L., S.L.B. & S.L.I. 12 - 13UL approved metal conduit & fittings: R.W.S. 14 - 15Instrumentationhose (inter-locked) without a cover: U.I.S. 16Metal conduits (inter-locked) without a cover: U.I. 17Fittings for U.I. 18 - 21
ANAMET HIPROJACKET & THERMOJACKET
Extreme heat resistant materials: Hiprojacket, Hiprotape, Thermojacket 22 - 23
ANACONDA LIQUIDTITE
Liquidtite metal conduit with a smooth cover: N 24
ANACONDA SEALTITE
Metal conduits with a smooth cover: E.F./ O.R./ H.C./ H.C.X./ Z.H.L.S.,H.F.X./ H.T.D.L./ Z.H.U.A./ SHIELDTITE 25 - 33
Anaconda fittings (nickel plated brass) for Anaconda Sealtite 34 - 39
Anamet fittings (zinc plated steel) for Anaconda Sealtite
40 - 43ATEX fittings for Anaconda Sealtite 44Accessories for Anamet fittings 45 - 47Stainless steel innercore conduit Anaconda Sealtite; :.H.C.I./ H.F.I. 48 - 49
Anaconda stainless steel fittings for Anaconda Sealtite 50 - 51Non- metallic conduits (UL/CSA) & fittings with a smooth cover: C.N.P 52 - 53Non- metallic conduits (UL/CSA) & fittings with a smooth cover: N.M.U.A. 54 - 57
ANA-QUICK POLYAMID CONDUIT SYSTEM
Ana-Quick Polyamide conduits (UR) : PA6L, PA6S, PA6V0, PA12S 58 - 61Ana-Quick fittings ISO 62 - 65
Ana-Quick fittings PG 66 - 67Accessories for Ana-Quick conduit system 68
ANAMET PLASTIC CONDUIT SYSTEMS
Anamet Gigant Polyamide conduit system 69Anamet Spiral reinforced conduit system : M.P.C. & M.P.U. 70Anamet fittings for M.P.C. & M.P.U. 71
Al l in th is catalogue mentioned information is subject to change, Anamet Europe B.V. reservesthe right to alter specifications without pri or notice.
-
7/27/2019 Download Electrical Catalogue
4/72
4
9 10 11 17 24 25 26 27 48 28 30 49 31
4 4 3 5 3 4 4 4 4 4 4 4 4
4 4 3 4 4 4 4 4 4 4 4 4 4
5+ 5+ 5+ 5+ 3 4 3 5 5 5+ 5 5 4
6+ 6+ 7+ 7+ 1+ 1+ 2+ 3 3 4+ 3 3 1+
4 4 4 4 4 4 4 4 4 4 4 4 4
1 1 0 0 3 3 3 3 3 3 3 3 3
4 4 4 4 6 6 6 6 6 6 6 6 6
0 0 0 0 7 7 7 7 7 7 7 7 7
2 2 4 4 3 3 3 3 4 3 3 4 3
3 4 3 4 4 4 4 4 4 4 4 4 4
1 1 1 1 1 1 1 1 1 2 1 1 1
0 0 0 0 0 0 0 0 0 0 0 0 0
- - - - **** **** **** **** **** **** **** **** ****
-55 -55 -100 -100 -15 -25 -15 -45 -45 -55 -45 -45 -25
+300 +300 +600 +600 +70 +70 +100 +105 +105 +145 +105 +105 +80
- - - - +90 +90 +120 +120 +120 +160 +125 +125 +100
**** **** **** **** *** *** **** *** *** ** **** **** **
**** **** **** **** * * * * * * ** ** *
**** **** **** **** ** *** *** *** *** **** **** **** **
**** **** **** **** * * * * * * *** *** ****
**** **** **** **** ** ** *** *** *** *** **** **** ***
**** **** **** **** - - - - - - **** **** ****
**** **** **** **** - **** **** - - - **** **** ***** *** * * * * * * * * * * *
- - - - - - - - - - - - -
- - - - - - - - - F5 F1 F1 F1
- - - - - - - - - 24,6 24,1 24,1 35,8
Liquid-tightness
Minimum temperature (C)
Maximum temperature (C)
Intermittent max. temperature (C)
Oil resistance
Solvent resistance
Flexibility
Low smoke development
UV-resistance
Halogen free
RoHS
EMI/EMC shielding
UL/CSA
NF F 16-101 Smoke-Index
Oxygen-Index
Conduit type (group)
Most important feature
Conduit type (model)
Cataloque page
Compression resistance
Impact resistance
Minimum temperature (C)
Maximum temperature ( C)
Bending resistance
Electrical properties
Resistance to ingress
of solid objects ( I )
Resistance to ingress
of water ( P )
Corrosion resistance
Tensile strength
Flame propagation
Suspended load capacity
Legend value:
**** excellent
*** good
** fair
* poor
- not applicable
or unknown
*1 Classification according to EN 50086 counts as a minimum for the complete range of sizes. Though, for some sizes in
the range a higher classification is possible. Consult your Anamet representative for more information.
EN 50086 CL ASSIFICATION*1 (also explanat ion at page 6)
OTHER FEATURES
P R O D U C T - C H O I C E - T A B L E
MULTIFLEX LIQUIDTITE SEALTITE SEALTITE SEALTITE
NO COVER ECONOMIC LEADFREE HIGH TEMPERATURE HALOGENFREE
S.L. S.L.B S.L.I. U.I. N. E.F. O.R. H.C. H.C.I. H.C.X. H.F.X. H.F.I. Z.H.L.S.
Construction innercore SquareSquare Square Inter Square Square Square Square Square Inter Square Square Square
locked locked locked locked locked locked locked locked locked locked locked locked locked
Material innercore GS GS INOX INOX GS GS GS GS INOX GS GS INOX GS
Material cover - GS Braid - - PVC PVC PVC PVC PVC TPE PU PU Polyolefin
Colour Standard Metal Metal Metal Metal Black Black Black Black Black Black Black Black Black
Alternative - - - - - Grey Blue - - - - - -
Legend material innercore:
GS : High quality galvanized steel
INOX : Stainless steel AISI 304 (Mat. Nr. 1.4301)
FG : Fibre glass
-
7/27/2019 Download Electrical Catalogue
5/72
5
32 33 52 54 22 23 58 59 60 61 70 70
4 4 1 2 0 0 1 2 3 2 3 3
4 4 3 3 0 0 1 2 3 2 3 3
5 5 3+ 3+ 5+ 4 4+ 4+ 4+ 4+ 3+ 4+
3 1+ 1 1+ 6+ 7+ 4 4 4 2+ 1+ 2
4 4 4 4 4 4 4 4 4 4 4 4
3 3 2 2 0 0 0 0 0 0 0 0
6 6 6 6 6 4 6 6 6 6 6 6
7 7 7 7 7 0 7 7 7 7 7 7
3 3 4 4 4 4 4 4 4 4 4 4
4 4 4 4 0 0 1 2 3 2 0 0
1 1 2 1 1 1 1 1 1 1 1 1
0 0 0 0 0 0 0 0 0 0 0 0
**** **** **** **** **** - **** **** **** **** **** ****
-45 -45 -20 -20 -50 -25 -40 -40 -40 -40 -20 -40
+105 +80 +60 +80 +260 +538 +120 +120 +120 +100 +80 +90
+120 +100 +80 +100 +1650 - +150 +150 +150 +130 - -
*** **** *** *** **** *** *** *** *** *** ** ****
* ** * * ** ** ** ** ** ** * **
*** **** * ** **** *** **** *** *** **** **** ****
* ** * * ** ** *** *** *** *** * **
*** **** *** *** ** ** *** *** *** *** ** ***
- **** - - - - **** **** **** **** - -
- - - **** - - **** **** **** **** - -*** *** - - - - - - - - - -
**** **** **** **** - - - UR UR - - -
- - - - - - - - - - - -
- - - - 42,5 - - - - - - -
EN 50086 CLA SSIFICATION*1 (also explanat ion at page 6)
P R O D U C T - C H O I C E - T A B L E
OTHER FEATURES
SEALTITE SEALTITE HIPROJACKET ANA-QUICK SPIRAL CONDUIT
UL / CSA UL / CSA HEAT RESISTANT POLYAMIDE CONDUIT LIGHT STRENGTH
H.T.D.L Z.H.U.A. C.N.P N.M.U.A Hiprojacket Thermojacket PA6L PA6S PA6V0 PA12S MPC MPU
Construction innercore Square Square Smooth Smooth Woven Braid corr. corr. corr. corr. Spiral Spiral
locked locked bore bore cover profile profile profile profile
Material innercore GS GS PVC PVC FG FG PA6 PA6 PA6 PA12 Metal Metal / PVC
Material cover PVC PU PVC - Silicone Coating - - - - PVC PU
Colour Standard Black Black Orange Grey Red Gold Black Black Black Black Grey Blue
Alternative Grey - Grey - - - - Grey Grey Grey - -
Liquid-tightness
Minimum temperature ( C)
Maximum temperature (C)
Intermittent max. temperature (C)
Oil resistance
Solvent resistance
Flexibility
Low smoke development
UV-resistance
Halogen free
RoHS
EMI/EMC shielding
UL/CSA
NF F 16-101 Smoke-Index
Oxygen-Index
Conduit type (group)
Most important feature
Conduit type (model)
Cataloque page
Compression resistance
Impact resistance
Minimum temperature (C)
Maximum temperature ( C)
Bending resistance
Electrical properties
Resistance to ingress
of solid objects ( I )
Resistance to ingress
of water ( P )
Corrosion resistance
Tensile strength
Flame propagation
Suspended load capacity
Legend value:
**** excellent
*** good
** fair
* poor
- not applicable
or unknown
*1 Classification according to EN 50086 counts as a minimum for the complete range of sizes. Though, for some sizes in
the range a higher classification is possible. Consult your Anamet representative for more information.
Legend material innercore:
GS : High quality galvanized steel
INOX : Stainless steel AISI 304 (Mat. Nr. 1.4301)
FG : Fibre glass
-
7/27/2019 Download Electrical Catalogue
6/72
-
7/27/2019 Download Electrical Catalogue
7/72
7
A B C D
A B C D
I N S T A L L A T I O N I N S T R U C T I O N A N A C O N D A F I T T I N G SMounting for Sealt i te
condu i t w i th cover
Mount ing f or SL / UI
condu i t w i thout cover
ANA CONDA SEALTI TE, LI QUIDTITE, an d NMUA condu i ts
The Anaconda fittings are easy to install. Place the counter nut (part A) with the thread to thefront over the conduit, place the plastic sealring (part B) over the conduit, turn the ferrule (part C)in the conduit (hand-tight), place the body (part D) and screw the counter nut hand-tight.Afterwards with a wrench 1 or 2 turns and the fitting is installed IP 67 liquid-tight.
ANA CONDA SL / SL B / SL I / UI condu i ts
The Anaconda fittings are easy to install. Place the counter nut (part A) with the thread to thefront over the conduit, place the metal clamp-ring (part B), turn the ferrule (part C) in the conduit(hand-tight), place the body (part D) and screw the counter nut hand-tight. Afterwards with awrench 1 or 2 turns and the fitting is tightly installed.
A N A C O N D A C O N D U I T E A S Y T O I N S T A L L
With a large diversity of applications, usage and installation, there is a variety of possibilities for cutting, sawingof conduit. In this overview we will try to mention the most important.
Sawing in a product ion environment
The easiest way to cut Anaconda conduit in a production environment is with a band saw.By using a 4 - 5 mm wide, 0,6 - 0,8 mm thick and 24 teeth band, on high speed, all conduits withoutcover are easy to cut. Conduit with cover will need a band with about ca. 20 teeth at a mediumspeed. All safety precautions should be taken care of.
For braided conduit, we advise to put a band of masking tape over the conduit before cutting,at the site of the cut, this also makes fittings easier to install.
For full-plastic conduits the same procedure can be used, cutting with a craft knife is also an option.
At larger sizes, from 1 1/2, the usage of a cutting-flex is an option.
Sawing in a non-product ion env i ronment , condu i ts w i thouth cover
The easiest way to cut Anaconda conduit without a cover, in a non-production environmentis with a hacksaw.
Another often used method is to break the conduit (only possible with square-locked profile)and cut it with tin snips or steel shears.
For braided conduit, we advise to put a band of masking tape over the conduit before cutting, atthe site of the cut, this also makes fittings easier to install.
For full-plastic conduits the same procedure can be used, cutting with a craft knife is also an option.
At larger sizes, from 1 1/2, the usage of a cutting-flex is an option.
Sawing in a non-product ion environment, conduits with cover
The easiest way to cut Anaconda conduit with a cover, in a non-production environmentis with a hacksaw.
Another option is to cut the cover, with a Stanley-knife, and to break the conduit (only possiblewith square-locked profile) and cut it with tin snips or steel shears.
For braided conduit, we advise to put a band of masking tape over the conduit before cutting, atthe site of the cut, this also makes fittings easier to install.
For full-plastic conduits the same procedure can be used, cutting with a craft knife is also an option.
At larger sizes, from 1 1/2, the usage of a cutting-flex is an option.
-
7/27/2019 Download Electrical Catalogue
8/72
-
7/27/2019 Download Electrical Catalogue
9/72
9
5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M16/M20 M16/M20 M20 M25 M32 M40 M50 M63
9/11 11/13,5 16 21 29 36 42 48
10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6
12,8 15,5 18,9 23,9 30,0 38,7 44,4 55,7
50 60 75 90 120 135 165 210
65 85 110 140 170 215 250 300
30 30 30 30 30 30 30 30
107.010.2 107.012.2 107.016.2 107.020.2 107.026.2 107.035.2 109.040.2 109.050.2
A N A C O N D A M U L T I F L E X c o n d u i t t y p e S . L .
Trade s ize SL In c h
Fi t t i ng s ISO
PG
Ins ide diameter mm
Outs ide diameter mm
Ben di ng r ad iu s s tat ic mm
(cen ter l i ne) dynamic mm
Standard car ton m
Ar t icl e N o.
S.L. : Flex ib le , s imple & qu ic k i ns tal l at i on
The Anamet type S.L. conduit is based on the square-locked Anaconda Sealtite
construction which results in a good mechanical stability and extreme flexibility. The
S.L. is made of galvanised steel and is being applied as an instrumentation hose inthe steel and aluminium foundry industry, machine and apparatus-building and the
security industry. The S.L. is exellent to protect cables against metal particles and
against vandalism or rodents.
Construction : Galvanized steel, square-locked.
Temperature : -55C to +300C.
Colour : metal coloured.
Special remarks:
* Conduit in the sizes 1 1/2 and 2 with inter-locked profile.* With exception of the sizes 1 1/2 and 2 all conduits are stock items, please
note a deliverey time for the sizes 1 1/2 and 2 of 4 till 6 weeks.
* Bigger or different sizes or different package sizes are on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5+ -55C
Maximum temperature 6+ +300C
Bending resistance 4 Flexible
Electrical proporties 1 With continuity
characteristics
Resistance to ingress of solid 4 Protected for particles
foreign objects (I) > 1,0 mm
Resistance to ingress of 0 None declared
water (P)
Corrosion resistance 2 Medium / Medium
inside / outside
Tensile strength 3 Medium (500 N)
Resistance to flame 1 Non-flamepropagation propagating
Suspended load capacity 0 None declared
Mul t i f lex t ype S .L .
The sui table f i t t ings for Mult i f lex type S.L. are ment ioned onpages 12 and 13.
Square-locked profile
-
7/27/2019 Download Electrical Catalogue
10/72
1 0
5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M16/M20 M16/M20 M20 M25 M32 M40 M50 M63
9/11 11/13,5 16 21 29 36 42 48
10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6
14,2 16,9 20,3 25,3 31,4 40,5 46,2 57,5
50 60 75 90 120 135 165 210
65 85 110 140 170 215 250 300
30 30 30 30 30 30 30 30
107.710.2 107.712.2 107.716.2 107.720.2 107.726.2 107.735.2 109.740.2 109.750.2
Mult i f lex type S.L.B.
The sui table f i t t in gs for Mult i f lex type S.L.B. are ment ionedon pages 12 and 13.
A N A C O N D A M U L T I F L E X c o n d u i t t y p e S . L . B .
Special remarks:
* Conduit in the sizes 1 1/2 and 2 with inter-locked profile.* Sizes 3/8 till 1are stock items, please note a deliverey time for the other
of 4 till 6 weeks.
* Bigger or different sizes or different package sizes are on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5+ -55C
Maximum temperature 6+ +300C
Bending resistance 4 Flexible
Electrical proporties 1 With continuity
characteristics
Resistance to ingress of solid 4 Protected for particles
foreign objects (I) > 1,0 mm
Resistance to ingress of 0 None declared
water (P)
Corrosion resistance 2 Medium / Medium
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flamepropagation propagating
Suspended load capacity 0 None declared
Square-locked profile
S.L.B.: Flexible and robus t
Type Multiflex S.L.B. is very useful for situations where a robust metal conduit and a
high flexibility are demanded. This conduit has a square-locked construction in
combination with a galvanized steel braid. In combination with the special fittings thisconduit is easy and quick to install. Type Multiflex S.L.B. is particularly used in
(mechanical) critical situations, such as machinebuilding, steel works but also in
transport systems and security. The S.L.B. is excellent in protecting cables against
metal particles and against vandalism or rodents.
Construction : Galvanized steel, square-locked.
Temperature : -55C to +300C.
Colour : Metal coloured
Trade s ize SLB In c h
Fi t t i n g s ISO
PG
Ins ide diameter mm
Outs ide diameter mm
Ben di ng rad iu s s tat ic mm
(cen ter l in e) dynamic mm
Standard car ton m
Ar t ic le No.
-
7/27/2019 Download Electrical Catalogue
11/72
-
7/27/2019 Download Electrical Catalogue
12/72
1 2
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25x1,5 M32x1,5 M40x1,5 M50x1,5 M63x1,5
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
8,3 8,3 10,2 10,2 13,6 18,5 23,8 31,8 36,8 47,8
35 36 35 36 37 40 46 52 56 66
12 13 12 13 13 15 15 16 18 20
26 26 26 26 29 35 45 54 63 77
24 24 24 24 27 33 43 52 60 74
50 50 50 50 50 25 10 5 5 4
812.015.6 812.014.6 812.016.6 812.017.6 812.020.6 812.025.6 812.032.6 812.040.6 812.050.6 812.063.6
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M16 M20 M16 M20 M20 M25 M32 M40 M50 M63
9 11 11 13,5 16 21 29 36 42 48
M16x1,5 - M16x1,5 - M20x1,5 M25x1,5 M32x1,5 - - -
5/16 - 3/8 - 1/2 3/4 1 - - -
8,3 - 10,2 - 13,6 18,5 23,8 - - -
41 - 41 - 43 48 54 - - -
12 - 12 - 13 15 15 - - -
26 - 26 - 29 35 45 - - -
24 - 24 - 27 33 43 - - -
50 - 50 - 50 25 10 - - -
813.015.6 - 813.016.6 - 813.020.6 813.025.6 813.032.6 - - -
M16x1,5 - M16x1,5 M20x1,5 M20x1,5 M25x1,5 M32x1,5 M40x1,5 - -
5/16 - 3/8 3/8 1/2 1/2 3/4 1 - -
4-8 - 4-8 6-10,2 6-12 10-13,6 13-18 18-23,8 - -
57 - 57 57 59 62 70 83 - -
12 - 12 12 12 12 15 15 - -
26 - 26 26 29 29 35 45 - -
24 - 24 24 27 27 33 43 - -
18 - 18 22 22 27 34 43 - -
25 - 25 25 25 25 25 10 - -
812.715.6 - 812.716.6 812.717.6 812.720.6 812.722.6 812.728.6 812.735.6 - -
A
B
E (SLW)
C
AB
E (SLW)
C
E (SLW)
E (SLW)
A
B
F (SLW)
C
A N A C O N D A F I T T I N G S f o r S . L . / S . L . B . / S . L . I
ISO straight f i t t ing, male f ixed, nickel plated brass ( incl. connection set)
AN AC ONDA f it t in gs for S.L. / S.L. B. / S.L .I .These IP 40 straight fitt ings have a temperature range of -45C til l +250oC. The cable-hose fitting has a temperature range of -40oC till +100oC, in case
of a cable-hose fitting an IP rate for the switchbox of IP 68 can be obtained. Anaconda ISO fittings are available from stock. Please note that the connection
set will be delivered separately. There are more combinations of fittings possible for the SL / SLB / SLI conduits. All fittings mentioned on the pages 34 till 39in combination with the connection set of page 13 are possible. At temperatures above 105C the NBR O-ring must be removed, a Neoprene sealring can be
an option (see page 39).
ISO straight f i t t ing, male swivel, nickel plated brass ( incl. connection set)
ISO straight f i t t ing, male f ixed, nickel plated brass ( incl. connection set)
Trade size SL/SLB/SLI
Fi t t ings ISO
PG
ISO thread size
SL/SLB/SLI type inch
Min. intern diam. mm
Dimensions in mm A
B
C
E
Standard pack. pcs.
Ar ti cl e No .
ISO thread size
SL/SLB/SLI type inch
Min. intern diam. mm
Dimensions in mm A
B
C
E
Standard pack. pcs.
Ar ti cl e No .
ISO thread size
SL/SLB/SLI type inch
Cable min - max mm
Dimensions in mm A
B
C
E
F
Standard pack. pcs.
Ar ti cl e No .
-
7/27/2019 Download Electrical Catalogue
13/72
1 3
- - - - 1/2 3/4 1 1 1/4 1 1/2 2
- - - - 13,6 18,5 23,8 31,8 36,8 47,8
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - - - - - - -
- - - - 25 10 10 5 5 3
- - - - 883.416.0 883.420.0 883.426.0 883.435.0 883.440.0 883.450.0
M16 M20 M16 M20 M20 M25 M32 M40 M50 M63
9 11 11 13,5 16 21 29 36 42 48
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
8,3 8,3 10,2 10,2 13,6 18,5 23,8 31,8 36,8 47,8
- - - - - - - - - -
- - - - - - - - - -
25 25 25 25 25 25 25 25 25 25
817.210.6* 817.210.6* 817.312.6 817.312.6 817.316.6 817.320.6 817.326.6 817.235.6* 817.240.6* 817.250.6*
9 11 11 13,5 16 21 29 36 42 48
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
8,3 8,3 10,2 10,2 13,6 18,5 23,8 31,8 36,8 47,8
35 35 35 35 37 40 46 52 56 66
12 12 12 12 13 15 15 16 18 20
26 26 26 26 29 35 45 54 63 77
24 24 24 24 27 33 43 52 60 74
50 50 50 50 50 25 10 5 5 4
810.009.6 810.010.6 810.011.6 810.013.6 810.016.6 810.021.6 810.029.6 810.036.6 810.042.6 810.048.6
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M16 M20 M16 M20 M20 M25 M32 M40 M50 M63
9 11 11 13,5 16 21 29 36 42 48
A
B
E (SLW)
C
Connect ion set , ( ferrule and c lampr i ng nick el p lated brass)
Trade size SL/SLB/SLI
Fi t t ings ISO
PG
PG straight f i t t ing , male, f ixed, nickel plated brass ( incl. connection set)
PG thread s ize
SL/SLB/SLI type inch
Min. intern diam. mm
Dimens ions in mm A
B
C
E
Standard pack. pcs.
A rt icl e No .
Conduit connector , to jo in 2 conduits (z inc plated)
SL/SLB/SLI type inch
Min. intern diam. mm
Standard pack. pcs.
A rt icl e No .
A N A C O N D A F I T T I N G S f o r S . L . / S . L . B . / S . L . I
* Only the brass clampring will be delivered as the standard ferrule is already suitable for this application.
AN AC ONDA f it t in gs for S.L . / S.L. B. / S.L. I.
These IP 40 straight fitt ings have a temperature range of -45C til l +250oC. The cable-hose fitting has a temperature range of -40oC till +100oC, in case of a
cable-hose fitting an IP rate for the switchbox of IP 68 can be obtained. Anaconda PG fittings are available from stock. Please note that the connection set willbe delivered separately. There are more combinations of fittings possible for the SL / SLB / SLI conduits. All fittings mentioned on the pages 34 till 39 incombination with the connection set mentioned on this page are possible. At temperatures above 105C the NBR O-ring must be removed, a Neoprene
sealring can be an option (see page 39).
ISO thread s ize
PG thread s ize
SL/SLB/SLI type inch
Min. intern diam. mm
Standard pack. pcs.
A rt icl e No .
-
7/27/2019 Download Electrical Catalogue
14/72
1 4
5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2
1/2 1/2 1/2 3/4 1 1 1/4 1 1/2 2
- - - - - - - -
- 9,8 16,1 20,9 25,9 32,4 39,1 51,8
- 14,9 22,6 27,3 34,0 40,4 48,3 61,0
- 60 90 115 145 180 215 285
- 85 140 165 225 270 300 390
- 30 30 30 15 15 7,5 7,5
- 332.112.1 332.116.1 332.120.1 332.126.1 332.135.1 332.140.1 332.150.1
A N A M E T M U L T I F L E X c o n d u i t t y p e R . W . S .
R.W.S.: UL approved condui t
The construction of the R.W.S. conduit is square-locked, due to its round form the
compression and impact resistance is very high. The R.W.S. complies to the heavyUL standard and is suitable for applications where besides flexibility a high mechanical
resistance is demanded. The R.W.S. is frequently used in heavier applications in the
machine and apparatus-building such as; kitchen apparatus, cool- , freeze-apparatus
and other industrial appliances, in particular those for export purposes.
Construction : Galvanized steel, square-locked.
Special approvals : UL-1 (file # E 11831)
Temperature : -45C to +250C.
Colour : Metal coloured.
Mult i f lex type R.W.S.
The sui table f i t t ings for Mult i f lex type R.W.S. are ment ionedon page 15.
Trade s ize RWS In c h
Fi t t ings NPT
ISO
Ins ide diameter mm
Outs ide diameter mm
Ben di ng rad iu s s tat ic mm
(cen ter l i ne) dynamic mm
Standard car ton m
Ar t ic le No.
Special remarks:
* Also available in Aluminium, type RWA, dimensions identical, with UL approval(UL file # E 98045). .
* Bigger or different sizes not available. Different package sizes are on demand.
* All mentioned conduits are no stock item, please notice a delivery time of
3 till 4 weeks.* Conduit size 3/8 is also available with CSA approval.
Square-locked profile
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 6 +250C
Bending resistance 4 Flexible
Electrical proporties 1 With continuity
characteristics
Resistance to ingress of solid 4 Protected for particles
foreign objects (I) > 1,0 mm
Resistance to ingress of 0 None declared
water (P)
Corrosion resistance 2 Medium / Medium
inside / outside
Tensile strength 3 Medium (500 N)
Resistance to flame 1 Non-flamepropagation propagating
Suspended load capacity 0 None declared
-
7/27/2019 Download Electrical Catalogue
15/72
1 5
- 1/2" 1/2" 3/4" 1" 1.1/4" 1 1/2 2
- 3/8" 1/2" 3/4" 1" 1.1/4" 1 1/2 2
- 9,8 13,7 18,8 23,8 31,6 36,8 48,0
- 26 36 39 45 49 53 60
- 11 11 11 14 16 18 19
- 28 36 40 50 57 64 78
- 25 25 25 10 10 5 5
- 296.012.0 296.016.0 296.020.0 296.026.0 296.035.0 296.040.0 296.050.0
5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2
1/2 1/2 1/2 3/4 1 1 1/4 1 1/2 2
- - - - - - - -
- 1/2" 1/2" 3/4" - - - -
- 3/8" 1/2" 3/4" - - - -
- 7,8 11,7 16,8 - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- - - - - - - -
- 50 50 25 - - - -
- 296.112.0 296.116.0 296.120.0 - - - -
- 1/2" 1/2" 3/4" 1" 1.1/4" 1 1/2 2
- 3/8" 1/2" 3/4" 1" 1.1/4" 1 1/2 2
- 9,8 13,7 18,8 23,8 31,6 36,8 48,0
- 28 38 42 59 70 95 102
- 9 10 11 14 16 19 19
- 44 54 61 73 102 152 152
- 28 36 40 50 57 64 78
- 50 25 10 5 5 5 5
- 296.912.0 296.916.0 296.920.0 296.926.0 296.935.0 296.940.0 296.950.0
A
B
C
A
B
C
D
A N A M E T M U L T I F L E X f i t t i n g s f o r t y p e R . W . S .
NPT straight f i t t ing, z inc plated*
NPT 90 f i t t ing, z inc plated*
NPT straight f i t t ing, screw-in type, z inc plated*
NPT thread size
For RWS type inch
Min. internal diam. mm
Dimensions in mm A
B
C
Stand. packaging pcs.
Ar t i cl e No .
Tr a de s i ze R WS I n ch
Fi t t i ngs ISO
PG
NPT thread size
For RWS type inch
Min. internal diam. mm
Dimensions in mm A
B
C
D
Stand. packaging pcs.
Ar t i cl e No .
NPT thread size
For RWS type inch
Min. internal diam. mm
Dimensions in mm
Stand. packaging pcs.
Ar t ic le No .
AN AM ET fi tt in gs for R.W.S .
These IP 40 straight fi ttings have a temperature range of -45C till +250oC. In combination with the insulation insert the temperature range is -45oC till +105oC.Fittings with ISO and PG thread are not available. Mentioned fittings are no stock item, please notice a delivery time of 3 till 4 weeks.
* Special note
Mentioned fitt ings are non-insulating. If single wires in the conduit and fitting are used , conform UL, an insulation insert must be used. These inserts are separately
available or in combination with the fitting already mounted (article no. ....... .1).
-
7/27/2019 Download Electrical Catalogue
16/72
-
7/27/2019 Download Electrical Catalogue
17/72
1 7
5/16 3/8 1/2 3/4 1 1 1/4 2
M16/M20 M16/M20 M20 M25 M32 M40 M63
9/11 11/13,5 16 21 29 36 48
9,5 13,0 17,0 22,0 26,0 34,0 52,0
12,5 16,0 21,0 26,0 30,0 39,0 58,0
50 65 75 90 120 175 285
60 80 100 125 160 220 340
30 30 30 30 30 30 30
512.010.0 512.012.0 512.016.0 512.022.0 512.025.0 512.034.0 512.050.0
A N A C O N D A M U L T I F L E X c o n d u i t t y p e U. I.
U. I. : Mec han ic al l y s tr ong and ex t ra f lexib i l it y f o r robo ti c s
The U.I. conduit is fully inter-locked and therefore extremely compression and
impact resistant. Type U.I is very well suited for applications where next to
flexibility also mechanical protection and excellent heat and corrosion resistanceare required. This explains why U.I. is being used so much in heavy robotics but
also in the steel and aluminium foundry industry, machine and apparatus
building, offshore, security, metal-, glass- and ceramics-industry.
Construction : Stainless steel (AISI 304), fully inter-locked.
Temperature : -100C to +600C.
Colour : Metal coloured.
Mult i f lex type U. I .
Trade s ize U.I. In c h
Fi t t i n g s ISO
PG
Ins ide diameter mm
Outs ide diameter mm
Bend ing r ad iu s s tat ic mm
(cen t er l i ne) dynamic mm
Standard car ton m
Ar ti cl e N o.
Special remarks:
* All sizes are stock items, for larger volumes please note a deliverey timeof 4 till 6 weeks.
EN 50086 Classification Value Description
Compression resistance 5 Very heavy (4000 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5+ -100C
Maximum temperature 7+ +600C
Bending resistance 4 Flexible
Electrical proporties 0 None declared
Resistance to ingress of solid 4 Protected for particles
foreign objects (I) > 1,0 mm
Resistance to ingress of 0 None declared
water (P)
Corrosion resistance 4 High / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flamepropagation propagating
Suspended load capacity 0 None declared
Inter-locked profile
The sui table f i t t ing s for Mult i f lex type U.I . are ment ioned onpages 18 t i l l 21.
-
7/27/2019 Download Electrical Catalogue
18/72
1 8
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 M63x1,5
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
6,8 6,8 9,8 9,8 13,9 18,5 22,8 30,8 47,8
35 36 35 36 37 40 46 52 66
12 13 12 13 13 15 15 16 20
26 26 26 26 29 35 45 54 77
24 24 24 24 27 33 43 52 74
50 50 50 50 50 25 10 5 4
812.015.7 812.014.7 812.016.7 812.017.7 812.020.7 812.025.7 812.032.7 812.040.7 812.063.7
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
M16 M20 M16 M20 M20 M25 M32 M40 M63
9 11 11 13,5 16 21 29 36 48
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 M63x1,5
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
6,8 6,8 9,8 9,8 13,9 18,5 22,8 30,8 47,8
23 23 23 23 25 30 34 39 53
12 12 12 12 13 15 15 16 20
26 26 26 26 29 35 45 54 77
33 33 33 33 33 36 46 54 71
22 22 22 22 27 33 42 51 74
50 50 50 50 50 25 10 5 4
812.415.7 812.414.7 812.416.7 812.417.7 812.420.7 812.425.7 812.432.7 812.440.7 812.463.7
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 M63x1,5
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
6,8 6,8 9,8 9,8 13,9 18,5 22,8 30,8 47,8
32 32 32 32 36 43 48 57 74
12 12 12 12 13 15 15 16 20
26 26 26 26 29 35 45 54 77
42 42 42 42 43 48 59 68 96
22 22 22 22 27 33 42 51 74
50 50 50 50 50 25 10 5 4
812.915.7 812.914.7 812.916.7 812.917.7 812.920.7 812.925.7 812.932.7 812.940.7 812.963.7
A
B
E (SLW)
C
A
B
E (SLW)
C
D
A
BE (SLW)
C
D
ISO straight f i t t ing , male, nickel plated brass ( incl. conn ection set)
ISO 45 f i t t ing, male, nickel pl ated brass ( incl. connecti on set)
ISO 90 f i t t ing, male, nickel pl ated brass ( incl. connecti on set)
AN AC ONDA f it ti ng s fo r U. I.
These IP 40 straight, 45 and 90 fittings have a temperature range of -45C till +250 oC. Also available in stainless steel (see page 21). The cable-hose fittinghas a temperature range of -40oC till +100oC, in case of a cable-hose fit ting an IP rate for the switchbox of IP 68 can be obtained. Anaconda ISO fittings are
available from stock. Please note that the connection set will be delivered separately. There are more combinations of fi ttings possible for the U.I. conduits. Allfittings mentioned onthe pages 34 till 39 in combination with the connection set of page 19 are possible. At temperatures above 105C the NBR O-ring must be
removed, a Neoprene sealring can be an option (see page 39).
Trade size UI Inch
Fi t t ings ISO
PG
ISO thread s ize
For UI size inch
Min. intern diam. mm
Dimensions in mm A
B
C
E
Standard pack. pcs.
Ar t icl e No .
ISO thread s ize
For UI size inch
Min. intern diam. mm
Dimensions in mm A
B
C
D
E
Standard pack. pcs.
Ar t icl e No .
ISO thread size
For UI size inch
Min. intern diam. mm
Dimens ions in mm A
B
C
D
E
Standard pack. pcs.
Ar t ic le No .
A N A C O N D A F I T T I N G S f o r M U L T I F L E X t y p e U . I .
-
7/27/2019 Download Electrical Catalogue
19/72
1 9
M16x1,5 - M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 -
5/16 - 3/8 3/8 1/2 1/2 3/4 1 -
4-6,8 - 4-8 6-9,8 6-12 10-13,9 13-18 18-22,8 -
57 - 57 57 59 62 70 83 -
12 - 12 12 12 12 15 15 -
26 - 26 26 29 29 35 45 -
24 - 24 24 27 27 33 43 -
18 - 18 22 22 27 34 43 -
25 - 25 25 25 25 25 10 -
812.715.7 - 812.716.7 812.717.7 812.720.7 812.722.7 812.728.7 812.735.7 -
M16x1,5 - M16x1,5 - M20x1,5 M25X1,5 M32x1,5 M40x1,5 M63x1,5
5/16 - 3/8 - 1/2 3/4 1 1 1/4 2
6,8 - 9,8 - 13,9 18,5 22,8 30,8 47,8
35 - 35 - 37 40 46 52 66
12 - 12 - 13 15 15 16 20
26 - 26 - 29 35 45 54 77
24 - 24 - 27 33 43 52 74
50 - 50 - 50 25 10 5 4
812.315.7 - 812.316.7 - 812.320.7 812.325.7 812.332.7 812.340.7 812.363.7
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 M63x1,5
9 11 11 13,5 16 21 29 36 48
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
6,8 6,8 9,8 9,8 13,9 18,5 22,8 30,8 47,8
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
- - - - - - - - -
25 25 25 25 25 25 25 10 4
817.210.9 817.210.9 817.213.9 817.213.9 817.216.9 817.220.9 817.226.9 817.235.9 817.250.9
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
M16 M20 M16 M20 M20 M25 M32 M40 M63
9 11 11 13,5 16 21 29 36 48
A
B
E (SLW)
C
E (SLW)
A
B
F (SLW)
C
Connec t ionset , (N icke l p la ted fe r ru le and c lampr ing)
ISO straight f i t t i ng, female, nickel plated brass ( incl. connecti on set)
ISO straight cable-hose-f it t i ng, male, nickel plated brass ( incl. conn ection set)
Trade s ize UI Inch
Fi t t ings ISO
PG
ISO thread size
For UI size inch
Min. intern diam. mm
Dimens ions in mm A
B
C
E
Standard pack. pcs.
Ar t icl e N o.
ISO thread size
PG thread s ize
For UI size inch
Min. intern diam. mm
Standard pack. pcs.
Ar ti cl e No .
AN AC ONDA f it t in gs for U. I.
These IP 40 straight fittings have a temperature range of -45C till +250oC. Also available in stainless steel (see page 21). The cable-hose fitting has atemperature range of -40oC till +100oC, in case of a cable-hose fit ting an IP rate for the switchbox of IP 68 can be obtained. Anaconda ISO fittings are
available from stock. Please note that the connection set will be delivered separately. There are more combinations of fi ttings possible for the U.I. conduits. Allfittings mentioned on the pages 34 till 39 in combination with the connection set of this page are possible. At temperatures above 105C the NBR O-ring must
be removed, a Neoprene sealring can be an option (see page 39).
ISO thread size
For UI size inch
Cable min - max mm
Dimens ions in mm A
B
C
E
F
Standard pack. pcs.
Ar t icl e N o.
A N A C O N D A F I T T I N G S f o r M U L T I F L E X t y p e U . I .
-
7/27/2019 Download Electrical Catalogue
20/72
-
7/27/2019 Download Electrical Catalogue
21/72
2 1
M16x1,5 M20x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 -
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 -
6,8 6,8 9,8 9,8 13,9 18,5 22,8 30,8 -
35 36 35 36 37 40 46 52 -
12 13 12 13 13 15 15 16 -
26 26 26 26 29 35 45 54 -
24 24 24 24 27 33 43 52 -
50 50 50 50 50 25 10 5 -
812.015.8 812.013.8 812.016.8 812.017.8 812.020.8 812.025.8 812.032.8 812.040.8 -
M16x1,5 - M16x1,5 - M20x1,5 M25x1,5 M32x1,5 - -
5/16 - 3/8 - 1/2 3/4 1 - -
6,8 - 9,8 - 13,9 18,5 22,8 - -
23 - 23 - 25 30 34 - -
12 - 12 - 13 15 15 - -
26 - 26 - 29 35 45 - -
33 - 33 - 33 36 46 - -
27 - 27 - 27 33 42 - -
50 - 50 - 50 25 10 - -
812.415.8 - 812.416.8 - 812.420.8 812.425.8 812.432.8 - -
M16x1,5 - M16x1,5 - M20x1,5 M25x1,5 M32x1,5 - -
5/16 - 3/8 - 1/2 3/4 1 - -
6,8 - 9,8 - 13,9 18,5 22,8 - -
32 - 32 - 36 43 48 - -
12 - 12 - 13 15 15 - -
26 - 26 - 29 35 45 - -
42 - 42 - 43 48 59 - -
27 - 27 - 27 33 42 - -
50 - 50 - 50 25 10 - -
812.915.8 - 812.916.8 - 812.920.8 812.925.8 812.932.8 - -
5/16 5/16 3/8 3/8 1/2 3/4 1 1 1/4 2
M16 M20 M16 M20 M20 M25 M32 M40 M63
9 11 11 13,5 16 21 29 36 48
A
B
E (SLW)
C
A
B
E (SLW)
C
D
A
BE (SLW)
C
D
ISO straight f i t t ing, male, stainless steel AISI 303 ( incl. connecti on set)
ISO 45 f i t t ing, m ale, stainless steel AISI 303 ( incl. connectio n set)
ISO 90 f i t t ing, m ale, stainless steel AISI 303 ( incl. connectio n set)
Trade si ze UI Inch
Fi t t ings ISO
PG
ISO thread size
For UI size inch
Min. intern diam. mm
Dimensions in mm A
B
C
E
Standard pack. pcs.
Ar ti cl e No .
ISO thread size
For UI size inch
Min. intern diam. mm
Dimensions in mm A
B
C
D
E
Standard pack. pcs.
Ar ti cl e No .
ISO thread size
For UI size inch
Min. intern diam. mm
Dimensions in mm A
B
C
D
E
Standard pack. pcs.
Ar ti cl e No .
AN AC ONDA f it t in gs for U. I.These stainless steel IP 40 straight, 45 and 90 fi ttings have a temperature range of -45C ti ll +250oC. Anaconda ISO fittings are no stock items, please
notice a delivery time from 6 till 8 weeks. PG available on demand. Also note that the connection set will be delivered separately. At temperatures above
105C the NBR O-ring must be removed, a Neoprene sealring can be an option (see page 39).
A N A C O N D A F I T T I N G S f o r M U L T I F L E X t y p e U . I .
-
7/27/2019 Download Electrical Catalogue
22/72
2 2
6 8 10 11 13 14 16 17
HJ-04* HJ-05* HJ-06* HJ-07 HJ-08* HJ-09 HJ-10* HJ-11
15 15 15 15 15 15 15 15
336.006.1 336.008.1 336.010.1 336.011.1 336.013.1 336.014.1 336.016.1 336.017.1
19 21 22 24 25 29 32 35
HJ-12* HJ-13 HJ-14* HJ-15 HJ-16* HJ-18* HJ-20* HJ-21
15 15 15 15 15 15 15 15
336.019.1 336.021.1 336.022.1 336.024.1 336.025.1 336.029.1 336.032.1 336.035.1
38 41 44 48 51 54 57 60
HJ-24 * HJ-26 HJ-28 HJ-30 HJ-32* HJ-34 HJ-36 HJ-38
15 15 15 15 15 15 15 15
336.038.1 336.041.1 336.044.1 336.048.1 336.051.1 336.054.1 336.057.1 336.060.1
64 70 73 76 79 89 95 102
HJ-40* HJ-44 HJ-46 HJ-48* HJ-50 HJ-56* HJ-60 HJ-64*
15 15 15 15 15 15 15 15
336.064.1 336.070.1 336.073.1 336.076.1 336.079.1 336.089.1 336.095.1 336.102.1
25 51 76 102 127 152 - -
HT-1 HT-2* HT-3* HT-4* HT-5 HT-6 - -
15 15 15 15 15 15 - -
337.025.1 337.050.1 337.076.1 337.100.1 337.127.1 337.152.1 - -
25 x 0,5 mm
HST-16*11
337.525.1
The ult imate heatprotection for cables
Up to approximately +100C most conduits offer good cable protection. Metal conduit itself withstands highertemperatures (up to +600C), but have limited insulation properties. Proper heat protection and insulation can be
provided by a high insulating outer jacket with protective cover, for example Hiprojacket and Hiprotape from Anamet
Europe B.V.. Hiprojacket and Hiprotape offer high temperature protection and the outer cover offers excellent re-
sistance to most industrial chemicals and hydraulic oils and are used in glass-, steel-, ceramics industry, steelworks,furnishing, machine- and aparatus-industry.
Construction : Woven fibre glass, the method of production creates a hollow space between outside
and inside cover.
Cover specifications : Ironoxyde silicon rubber. Withstands melted metal and intense heat radiation.
Special approvals : NFF 16-101: class I2, Oxygenindex LOI = 42,5 , flameretardant.
Temperature : +260C continous. Ti ll +1090C for approx. 20 minutes.
Till +1640C for 15-30 seconds.
Colour : Red
Hiprosiltape consists of specially compounded silicone rubber, which adheres only to itself. It is used to seal the ends of
Hiprojacket and Hiprotape or cables to prevent oil or water from wicking into the glass fibre and destroying insulationvalues. It can also be used to repair or join sections of Hiprojacket, or to provide a moisture proof seal over irregular
insulated shapes. Less expensive and more effective than clamps or liquid sealants.
A N A M E T H I P R O J A C K E T , H I P R O T A P E & H I P R O S I L T A P E
Trade size (ID) mm
Type
Standard packaging m
A rt icl e No .
Trade size (ID) mm
Type
Standard packaging m
A rt icl e No .
Trade size (ID) mm
Type
Standard packaging m
A rt icl e No .
Trade size (ID) mm
Type
Standard packaging m
A rt icl e No .
Trade s ize (width ) mm
Type
Standard packaging m
A rt icl e No .
Trade size (W x T) mm
TypeStandard packaging m
Ar ti cl e No .
- P lease note spec ial remarks p age 23 -
H I P R O J A C K E T ( c on d u i t )
H I P R O T A P E ( s l e e v e )
H I P R O S I L T A P E
-
7/27/2019 Download Electrical Catalogue
23/72
2 3
6 10 13 16 19 25 32 38 52 76 102
TJ-4 TJ-6 TJ-6 TJ-10 TJ-10 TJ-14 TJ-14 TJ-22 TJ-22 TJ-44 TJ-44
1,00 1,00 1,25 1,00 1,15 1,02 1,08 1,06 1,17 1,16 1,51
5 10 10 15 15 25 25 30 30 65 65
10 15 15 30 30 50 50 65 65 125 125
15 15 15 15 15 15 15 15 15 15 15
336.604.1 336.606.1 336.606.1 336.610.1 336.610.1 336.614.1 336.614.1 336.622.1 336.622.1 336.644.1 366.644.1
T H E R M O J A C K E T
A N A M E T T H E R M O J A C K E T
The easy alternative in heat protecti on for cables
In addition to Anamet Hiprojacket we also can offer Anamet Thermojacket. Anamet Thermojacketsleeve is an excelent durable heatprotector for conduits, cables and cabletrees. Thermojacket is
mostly used for applications where high temperature protection and long lengths are needed.
In transport systems and industrial installation Thermojacket is frequently used.
Construction : Woven fibre glass, saturated with a special heatprotection coating.
Cover specifications : Special coating. Withstands intense heat radiation.
Temperature : +538C continous.
Colour : Gold
Trade size mm
Type
Length to co ver 1 meter
Min. ins ide diam. mm
Max. ins ide diam. mm
Standard packaging m
A rt ic le No .
Speciale Remarks Thermojacket
* Because Themojacket is a woven sleeve, it is flexible and to strech for which different sizes can be covered with
one and the same type Thermojacket. Please notice that when the sleeve is stretched, more meters are necessary to
cover the same distance. In our calculation we have taken the diameter to be covered into consideration.
* Thermojacket is on demand avialble in longer lengths (30 meter)
* All mentioned items are stock item.
Speciale remarks Hiprojacket and Hiprotape
* Hiprojacket has a limited flexibility so the intermediate dimensions can be covered with one and the same size.
Please notice that the maximum difference is 3 mm and the mentioned size is the maximum size Hiprojacket.
* Hiprojacket is, on demand, available in longer length.
* Only the with * marked items are stock items, please notice for all other sizes a delivery time of 4 till 6 weeks.
A N A M E T H I P R O J A C K E T , H I P R O T A P E
& H I P R O S I L T A P E (see also page 22)
Temperature pro tect ion: Cold s ide versus warm side
Warm side Temp. Thermojacket (one layer) Hiprojacket (one layer) and
Thermojacket (double layer)
100 C 75 C 60 C200 C 150 C 120 C
300 C 250 C 220 C400 C 300 C 260 C
500 C 350 C 280 C
-
7/27/2019 Download Electrical Catalogue
24/72
2 4
5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M16/M20 M16/M20 M20 M25 M32 M40 M50 M63
9/11 11/13,5 16 21 29 36 42 48
1/2 1/2 1/2 3/4 1 1 1/4 1 1/2 2
10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6
14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9
50 60 75 90 120 150 200 250
75 100 125 160 200 240 290 350
30 30 30 30 30 30 25 25
667.010.0 667.012.0 667.016.0 667.020.0 667.026.0 667.035.0 667.040.0 667.050.0
A N A C O N D A L I Q U I D T I T E c o n d u i t t y p e N .
N: Universal
Type N is the economical solution for the universal Anaconda Sealti te conduit type
E.F. Type N is meant for applications where no extreme external parameters have
influence on the conduit and no frequent movements are demanded. Type N is,
among others, being used in machinebuilding, woodcuttingmachinery, conection ofcontrol panels and packagingmachinery. Liquidtite N is applied for quick and easy
mounting and a reasonable mechanical protection.
Construction : Galvanized steel core, square-locked thermoplastic
(PVC compound) cover.
Cover specifications : PVC, sunlight and UV resistant, suitable for outside
and burial installation.
Temperature : -15C to +70C, intermittent up to +90C.
Colour : Black
L iqu id t i te t ype N
The su i tab le f i t t ings and accessor ies fo r L iqu id t igh ttype N are ment ioned on pages 34 t i l l 47.
Special remarks:
* The dynamic values for sizes 1 1/2 and bigger are only valid above 0C.* With exception of the sizes 1 1/2 and 2 all items are stock item, please
notice for larger volumes a delivery time of 3 till 4 weeks. The bigger sizes1 1/2 and 2 have a deliverytime of 6 till 8 weeks.
* Reels only available on demand.
EN 50086 Classification Value Description
Compression resistance 3 Medium (750 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 3 -15C
Maximum temperature 1+ +70C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize N In c h
Fi t t i n g s ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Ben di ng rad iu s s tat ic mm
(cen ter l i n e) dynamic mm
Standard car ton m
A rt ic le N o. b lac k
-
7/27/2019 Download Electrical Catalogue
25/72
2 5
6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6 63,3 78,4
11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9 72,6 88,4
40 50 60 75 90 120 135 165 210 280 425
50 65 85 110 140 170 215 250 300 360 520
50 50 75 60 50 30 30 15 15 7,5 7,5
311.006.1 311.010.1 311.012.1 311.016.1 311.020.1 311.026.1 311.035.1 311.040.1 311.050.1 311.063.1 311.075.1
315.006.1 315.010.1 315.012.1 315.016.1 315.020.1 315.026.1 315.035.1 315.040.1 315.050.1 315.063.1 315.075.1
- 10 10 10 10 10 - - - - -
- 311.010.3 311.012.3 311.016.3 311.020.3 311.026.3 - - - - -
- 315.010.3 315.012.3 315.016.3 315.020.3 315.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 311.012.5 311.016.5 311.020.5 311.026.5 311.035.5 311.040.5 311.050.5 - -
- - 315.012.5 315.016.5 315.020.5 315.026.5 315.035.5 315.040.5 315.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
M12 M16/M20 M16/M20 M20 M25 M32 M40 M50 M63 M75 M85
7 9/11 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
A N A C O N D A S E A L T I T E c o n d u i t t y p e E . F .
E.F.: Uni versal
Type E.F. is the most universal applicable Anaconda Sealtite conduit. The E.F.,
with its leadfree cover, is meant for applications where no extreme external
parameters have influence on the conduit and therefore E.F. can be used in many
areas. The E.F. is, among others, being used in the apparatus- andmachinebuilding, panelbuilding, packagingmachines, machines for the paper-
recycling industry, machines for the farmacindustry and other internal transport-
systems.
Construction : Galvanized steel core, square-locked with cord packing,
thermoplastic cover (PVC / leadfree compound for the
size 1/4 till 1 1/4). From 1 1/2 a fully inter-locked
profile will be used. From 2 1/2 the conduit will have UL
approval (type EFST/UA).
Cover specifications : PVC, for the sizes 1/4 til l 1 1/4 leadfree according
RoHS, sunlight and UV resistant, suitable for outside
and burial installation.
Temperature : -25C to +70C, intermittent up to +90C.
Colour : Grey & black (black is recommended for outside installation).
Sealt ite type E.F.
The sui table f i t t ings and accessor ies for Sealt i tetype E.F. are ment ion ed on pages 34 t i l l 47.
Special remarks:* RoHS is related to the new European directive with regards to lead,
cadmium etc. which under specific circumstances applies for conduits.* With exception of the sizes 2 1/2 and 3 all items are stock item, please
notice for larger volumes a delivery time of 3 till 4 weeks. The bigger sizes2 1/2 and bigger have a delivery time of 6 till 8 weeks.
* Reels only available on demand.
* Bigger sizes 4 till 6 available on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 4 -25C
Maximum temperature 1+ +70C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize EF In c h
Fi t t i n gs ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
B en di ng radi us s tat ic mm
(cen ter l in e) dynamic mm
Standard car ton m
A rt ic le N o. g rey
A rt ic le N o. b lac k
Small car ton m
A rt ic le N o. g rey
A rt ic le N o. b lac k
Reels m
A rt ic le N o. g rey
A rt ic le N o. b lac k
-
7/27/2019 Download Electrical Catalogue
26/72
2 6
6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6 63,3 78,4
11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9 72,6 88,4
40 50 60 75 90 120 135 165 210 280 425
50 65 85 110 140 170 215 250 300 360 520
50 50 75 60 50 30 30 15 15 7,5 7,5
320.006.1 320.010.1 320.012.1 320.016.1 320.020.1 320.026.1 320.035.1 320.040.1 320.050.1 320.063.1 320.075.1
- 10 10 10 10 10 - - - - -
- 320.010.3 320.012.3 320.016.3 320.020.3 320.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 320.012.5 320.016.5 320.020.5 320.026.5 320.035.5 320.040.5 320.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
M12 M16/M20 M16/M20 M20 M25 M32 M40 M50 M63 M75 M85
7 9/11 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
O.R : Oi l & gr ease r es i stan t
Anaconda Sealtite O.R. is special developed for areas where conduit systems are
being exposed to oils and greases. As a result of the high resistance against these
substances the flexibility of the conduit is being safeguarded. With other (non-
resistant) covers these substances can lead to stiffening or even rupture of thecover. By using a leadfree compound this conduit can be used in many areas, such
as the machine-building industry, diesel-engines, generatorsets, metalpaper,
chemical and petrochemical industry.
Construction : Galvanized steel core, square-locked with cord packing,
thermoplastic cover (PVC / leadfree compound for the
size 1/4 till 1 1/4).
From 1 1/2 a fully inter-locked profile will be used.
Cover specifications: PVC, for the sizes 1/4 till 1 1/4 leadfree according
RoHS, sunlight and UV resistant, suitable for outside
installation. The cover is very good resistant against
oil and greases.
Temperature : -15C to +100C, intermittent up to +120C.
Colour : Black
A N A C O N D A S E A L T I T E c o n d u i t t y p e O . R .
Sealt ite type O.R.Special remarks:* RoHS is related to the new European directive with regards to lead,
cadmium etc. which under specific circumstances applies for conduits.* With exception of the sizes 2 1/2 and 3 all items are stock item, please
notice for larger volumes a delivery time of 3 till 4 weeks. The bigger sizes2 1/2 and bigger have a delivery time of 6 till 8 weeks.
* Reels only available on demand.
* Bigger sizes 4 till 6 available on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 3 -15C
Maximum temperature 2+ +100C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize OR In c h
Fi t t i ng s ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Ben di ng r ad iu s s tat ic mm(cen ter l i ne) dynamic mm
Standard car ton m
Ar t icl e N o. b lac k
Small car ton m
Ar t icl e N o. b lac k
Reels m
Ar t icl e N o. b lac k
The sui table f i t t ings and accessor ies for Sealt i tetype O.R. are ment ioned on pages 34 t i l l 47.
-
7/27/2019 Download Electrical Catalogue
27/72
2 7
6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6 63,3 78,4
11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9 72,6 88,4
40 50 60 75 90 120 135 165 210 280 425
50 65 85 110 140 170 215 250 300 360 520
50 50 75 60 50 30 30 15 15 7,5 7,5
317.006.1 317.010.1 317.012.1 317.016.1 317.020.1 317.026.1 317.035.1 317.040.1 317.050.1 317.063.1 317.075.1
- 10 10 10 10 10 - - - - -
- 317.010.3 317.012.3 317.016.3 317.020.3 317.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 317.012.5 317.016.5 317.020.5 317.026.5 317.035.5 317.040.5 317.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
M12 M16/M20 M16/M20 M20 M25 M32 M40 M50 M63 M75 M85
7 9/11 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
A N A C O N D A S E A L T I T E c o n d u i t t y p e H . C .
H.C.: Wide temper atu re r ange
If we look at high temperature ranges the Anaconda Sealtite type H.C. is a good
solution. The cover maintains its flexibility under high and low temperature
conditions. Type H.C. is prefered in areas where conduit systems are being
exposed to strong variations of temperatures. Type H.C. can be used in areas
where strong temperature changes occur and is, amongst others, being applied in
trainwarningsystems, transformers, woodcuttingmachines, sawmachines, security
systems in energy plants, chemical-, ceramic- and building-industry.
Construction : Galvanized steel core, square-locked with cord packing,
thermoplastic cover (PVC compound).
From 1 1/2 a fully inter-locked profile will be used.
Cover specifications: PVC, sunlight and UV resistant, suitable for outside
installation. The cover is good resistant against
oil and greases.
Temperature : -45C to +105C, intermittent up to +120C.
Colour : Black
Sealt ite type H.C.Special remarks:* Dynamic values only valid for circumstances above 0C.
* With exception of the sizes 2 1/2 and 3 all items are stock item, pleasenotice for larger volumes a delivery time of 3 till 4 weeks. The bigger sizes
2 1/2 and bigger have a delivery time of 6 till 8 weeks.* Reels only available on demand.
* Bigger sizes 4 till 6 available on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 3 +105C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trad e s i ze HC In c h
Fi t t i n gs ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
B en di ng radi us s tat ic mm(cen ter l in e) dynamic mm
Standard car ton m
A rt ic le N o. b lac k
Small car ton m
A rt ic le N o. b lac k
Reels m
A rt ic le N o. b lac k
The sui table f i t t ings and accessor ies for Sealt i tetype H.C. are ment ioned o n pages 34 t i l l 47.
-
7/27/2019 Download Electrical Catalogue
28/72
2 8
- - 12,6 16,0 21,0 26,5 35,1 40,3 51,6 - -
- - 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
- - 60 75 90 120 135 165 210 - -
- - 85 110 140 170 215 250 300 - -
- - 30 30 30 30 15 15 15 - -
- - 326.012.1 326.016.1 326.020.1 326.026.1 326.035.1 326.040.1 326.050.1 - -
- - 10 10 10 10 - - - - -
- - 326.012.3 326.016.3 326.020.3 326.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 326.012.5 326.016.5 326.020.5 326.026.5 326.035.5 326.040.5 326.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
- - M16/M20 M20 M25 M32 M40 M50 M63 - -
- - 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
H.C.X.: Extreme temperature range
Extreme cold, heat or temperature changes are conditions in which the H.C.X.
performs the best. The cover of this conduit has both a very high as low
temperature resistance, which also ensures that changes in the temperature are
not being transfered to the electrical wiring. The H.C.X. keeps its flexibility at low
temperatures. Type H.C.X. is often used in the train-building, for rolling stock and
installations, offshore, steelworks, founderies, apparatus- and machinebuilding,
especially for outside installations.
Construction : Galvanized steel core, square-locked with cord packing,
thermoplastic cover (TPE).
From 1 1/2 a fully inter-locked profile will be used.
Cover specifications : Thermoplastic elastomer, sunlight and UV resistant,
suitable for outside installation.
Temperature : -55C to +145C, intermittent up to +160C.
Colour : Black.
A N A C O N D A S E A L T I T E c o n d u i t t y p e H . C . X .
Sealt ite type H.C.X. Special remarks:* All sizes are stock item, please notice for larger volumes a delivery time
of 3 till 4 weeks.
* Reels only available on demand.* Bigger sizes 2 1/2 till 6 available on demand.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5+ -55C
Maximum temperature 4+ +145C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 2 Flame propagating
propagation
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize HCX In c h
Fi t t i ng s ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Ben di ng rad iu s s tat ic mm
(cen ter l i n e) dynamic mm
Standard car ton m
A rt ic le N o. b lac k
Small car ton m
A rt ic le N o. b lac k
Reels m
A rt ic le N o. b lac k
The sui table f i t t ings and accessor ies for Sealt i tetype H.C.X. are ment ioned on p ages 34 t i l l 47.
-
7/27/2019 Download Electrical Catalogue
29/72
2 9
- - 12,6 16,0 21,0 26,5 35,1 40,3 51,6 - -
- - 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
- - 80 90 110 120 135 200 275 - -
- - 100 125 160 200 240 290 380 - -
- - 30 30 30 30 15 15 15 - -
- - 304.012.1 304.016.1 304.020.1 304.026.1 304.035.1 304.040.1 304.050.1 - -
- - - - - - - - - - -
- - - - - - - - - - -
- - 250 150 120 90 60 45 22 - -
- - 304.012.5 304.016.5 304.020.5 304.026.5 304.035.5 304.040.5 304.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
- - M16/M20 M20 M25 M32 M40 M50 M63 - -
- - 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
EMP SHIELDING (MEOB.96_049 ELM)
SHIELDTITE
Frequency (MHz)Shielding
Effectiveness
(dB)
SHIELDTITE: EMI / EMP sh ield ing
The SHIELDTITE conduit has been developed according to MIL-STD 1310D
(military standard USA) and has an inter-locked construction with a bronze core.
This results in excellent shielding against electromagnetic fields, which is one of
the most occurring disturbing factors of electronic equipment. To exclude any
disturbances in your data-transport or apparatuses, SHIELDTITE will the best
solution. SHIELDTITE is used in machines and apparatuses, which need to be
shielded effectively from EMI and EMP fields, like for example in the military
sector, marine and airtraffic controle.
Construction : Bronze core, inter-locked, thermoplastic cover
(PVC compound).
Cover specifications: PVC, sunlight and UV resistant, suitable for outside
installation. The cover is good resistant against
oil and greases.
Temperature : -45C to +105C, intermittent up to +120C.
Colour : Grey.
A N A C O N D A S E A L T I T E c o n d u i t t y p e S H I E L D T I T E
Sealt ite type SHIELDTITE
Tr ad e s ize SHIEL DTITE In ch
Fi t t i n gs ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Bend ing r ad iu s s tat ic mm
(cen t er l i ne) dynamic mm
Standard car ton m
Ar t icl e No . g re y
Small car ton m
Ar t icl e No . g re y
Reels m
Ar t icl e No . g re y
The sui table f i t t ings and accessor ies for Sealt i tetype SHIELDTITE are mentioned on pages 34 ti l l 47.
Inter-locked profile
Special remarks:
* Dynamic values only valid for circumstances above 0C.
* Shielding characteristics are available through special report* All items are no stock item, please notice a delivery time of 8 till
12 weeks.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 3 +105C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
-
7/27/2019 Download Electrical Catalogue
30/72
3 0
6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6 - -
11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
40 50 60 75 90 120 135 165 210 - -
50 65 85 110 140 170 215 250 300 - -
30 30 30 30 30 30 15 15 15 - -
331.006.1 331.010.1 331.012.1 331.016.1 331.020.1 331.026.1 331.035.1 331.040.1 331.050.1 - -
- 10 10 10 10 10 - - - - -
- 331.010.3 331.012.3 331.016.3 331.020.3 331.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 331.012.5 331.016.5 331.020.5 331.026.5 331.035.5 331.040.5 331.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
M12 M16/M20 M16/M20 M20 M25 M32 M40 M50 M63 - -
7 9/11 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
H.F.X.: halogen f ree & very f lex ib le
A halogen free conduit for use in public areas. The features of the H.F.X. cover are
necessary in the field of environment and safety, as the European guidelines state
that certain areas need to be free of halogens. Another unique feature of the H.F.X.
is, that it is extremely flexible at both high as low temperatures. This makes the
H.F.X. very suitable for installations, which are subject to frequent movements. The
H.F.X. is often being applied in the subway, train and bus-building industry, in
closed areas, airports, tunnels and (subway) stations but also in the chemical- and
petrochemical-industry.
Construction : Galvanized steel core, square-locked with cord
packing, thermoplastic cover (Polyurethane).
From 1 1/2 a fully inter-locked profile will be used
Cover specifications : Polyurethane, sunlight and UV resistant, suitable for
outside installation. The cover is resistant against
oil and greases.
Special approvals : Flameproperties according NF F 16-101.
Temperature : -45C to +105C, intermittent up to +125C.
Colour : Black.
A N A C O N D A S E A L T I T E c o n d u i t t y p e H . F . X .
Sealt ite type H.F.X.EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 3 +105C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non-flame propagating
propagation
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize HFX In c h
Fi t t i n g s ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Ben di ng r ad iu s s tat ic mm
(cen t er l i ne) dynamic mm
Standard car ton m
Ar t icl e N o. b lac k
Small car ton m
Ar t icl e N o. b lac k
Reels m
Ar t icl e N o. b lac k
Special remarks:* With exception of the sizes 1 1/2 and 2 all sizes are stock item, please
notice for larger volumes a delivery time of 3 til l 4 weeks. For the sizes1 1/2 and 2 the delivery time is 6 till 8 weeks.
* Reels only available on demand.* For bigger sizes 2 1/2 till 4 see Z.H.U.A..
* Flameproperties tested according to NF F 16-101:
- Oxygenindex LOI = 24,1
- Conventional Index of Toxicity CIT = 6,8
- Maximum Smoke Density Dm = 94,27Full testreport by RATP - Eurailtest is available on demand.
The sui table f i t t ings and accessor ies for Sealt i tetype H.F.X. are mentioned on pages 34 ti l l 47.
-
7/27/2019 Download Electrical Catalogue
31/72
3 1
6,4 10,1 12,6 16,0 21,0 26,5 35,1 40,3 51,6 - -
11,5 14,4 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
40 50 60 75 90 120 135 165 210 - -
50 65 85 110 140 170 215 250 300 - -
30 30 30 30 30 30 15 15 15 - -
309.006.1 309.010.1 309.012.1 309.016.1 309.020.1 309.026.1 309.035.1 309.040.1 309.050.1 - -
- 10 10 10 10 10 - - - - -
- 309.010.3 309.012.3 309.016.3 309.020.3 309.026.3 - - - - -
- - 250 150 120 90 60 45 22 - -
- - 309.012.5 309.016.5 309.020.5 309.026.5 309.035.5 309.040.5 309.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
M12 M16/M20 M16/M20 M20 M25 M32 M40 M50 M63 - -
7 9/11 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
Z.H.L .S.: halogen f ree & low smoke
A halogen free, low smoke conduit for use in public areas. The features of the
Z.H.L.S. cover are necessary in the field of environment and safety, as the
European guidelines state that certain areas need to be free of halogens. The
Z.H.L.S. is optimal for use in the subway, train and bus-building industry, in closed
areas, airports, tunnels, (subway) stations and other infra-structure projects, but
also in hospitals, elevators, escalators and other public areas
Construction : Galvanized steel core, square-locked with cord
packing, thermoplastic cover (Polyolefin).
From 1 1/2 a fully inter-locked profile will be used.
Cover specifications : Polyolefin, sunlight and UV resistant, suitable for
outside installation.
Special approvals : Flameproperties according NF F 16-101.
Temperature : -25C to +80C, intermittent up to +100C.
Colour : Black.
A N A C O N D A S E A L T I T E c o n d u i t t y p e Z . H . L . S .
Sealt ite type Z.H.L.S.EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 4 -25C
Maximum temperature 1+ +80C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)
Resistance to flame 1 Non - flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize ZHLS In c h
Fi t t i n gs ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
B en di ng radi us s tat ic mm
(cen ter l in e) dynamic mm
Standard car ton m
A rt ic le N o. b lac k
Small car ton m
A rt ic le N o. b lac k
Reels m
A rt ic le N o. b lac k
Special remarks:
* With exception of the sizes 1 1/2 and 2 all sizes are stock item, pleasenotice for larger volumes a delivery time of 3 til l 4 weeks. For the sizes
1 1/2 and 2 the delivery time is 6 till 8 weeks.* Reels only available on demand.
* For bigger sizes 2 1/2 till 4 see Z.H.U.A..* Flameproperties tested according to NF F 16-101:
- Oxygenindex LOI = 35,8
- Conventional Index of Toxicity CIT = 4,47
- Maximum Smoke Density Dm = 173,51
Full testreport by RATP - Eurailtest is available on demand.
The sui table f i t t ings and accessor ies for Sealt i tetype Z.H.L.S. are ment ioned on pages 34 t i l l 47.
-
7/27/2019 Download Electrical Catalogue
32/72
3 2
- - 12,6 16,1 21,1 26,8 35,4 40,3 51,6 - -
- - 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
- - 70 90 115 145 175 205 240 - -
- - 85 110 140 170 215 250 300 - -
- - 60 60 45 30 15 15 15 - -
- - 330.012.2 330.016.2 330.020.2 330.026.1 330.035.1 330.040.1 330.050.1 - -
- - 10 10 10 10 - - - - -
- - 330.012.3 330.016.3 330.020.3 330.026.3 - - - - -
- - 150 150 120 90 60 45 30 - -
- - 330.012.5 330.016.5 330.020.5 330.026.5 330.035.5 330.040.5 330.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
- - M16/M20 M20 M25 M32 M40 M50 M63 - -
- - 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
H.T.D.L .: UL & CSA, wi de tem per at ur e r an ge
Type H.T.D.L. is the most used Anaconda Sealtite conduit with integral grounding
copper wire (ti ll 1.1/4"). The H.T.D.L. is UL & CSA approved and has a wide temperature
range. Because of the integrated copper grounding wire the H.T.D.L. also offers a fine
EMI/EMP shielding, which makes it useable for applications where a high degree of
electrical continuity is required. The H.T.D.L. perfectly suited for machines andinstallations that will be exported to countries outside Europe. You will find type
H.T.D.L. in transformers, paper-recycling machinery, internal transport, trains, airtrafic-
control, UMTS systems, machine-, paper- and apparatus-building industry.
Construction : Galvanized steel core, square-locked with integral copper
grounding wire, thermoplastic cover (PVC compound) .
From 1 1/2 a fully interlocked profile will be used.
Cover specifications: PVC, sunlight and UV resistant, suitable for outside
installation. The cover is good resistant against oil and
greases.
Special approvals : UL-360 (file #E18917) and CSA 22.2 (file 63790 / 15275)
Temperature : -45C to +105C, intermittent up to +120C.
Max. temperature according CSA is +75C.
Colour : Black.
A N A C O N D A S E A L T I T E c o n d u i t t y p e H . T . D . L .
Sealt ite type H.T.D.L. Special remarks:* Dynamic values for size 1 1/2 and bigger, only valid for circumstances above 0C.
* With exception of the sizes 2 1/2 and 3 all items are stock item, pleasenotice for larger volumes a delivery time of 3 till 4 weeks. The bigger sizes
2 1/2 and bigger have a delivery time of 6 till 8 weeks.* Approved as earthconnector if length is max. 1,5 meter (see UL 360)
* Complies with NEC sect. 351 A.
* Suitable to use in hazardous environments according NEC 501-4B
Class I, Division 2; Class II, Division 1 and 2; Class III, Division 1 and 2.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 3 +105C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize HTDL In c h
Fi t t i ng s ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
Ben di ng r ad iu s s tat ic mm
(cen ter l i ne) dynamic mm
Standard car ton m
Ar t icl e N o. b lac k
Small car ton m
Ar t icl e N o. b lac k
Reels m
Ar t icl e N o. b lac k
The sui table f i t t ings and accessor ies for Sealt i tetype H.T.D.L are ment i oned on pages 34 t i l l 47.
EMP SHIELDING (MEOB.96_049 ELM)
Frequency (MHz)ShieldingE
ffectiveness
(dB)
-
7/27/2019 Download Electrical Catalogue
33/72
3 3
- - 12,6 16,1 21,1 26,8 35,4 40,3 51,6 - -
- - 17,8 21,1 26,4 33,1 41,8 47,8 59,9 - -
- - 70 90 115 145 175 205 240 - -
- - 85 110 140 170 215 250 300 - -
- - 30 30 30 30 15 15 15 - -
- - 334.012.1 334.016.1 334.020.1 334.026.1 334.035.1 334.040.1 334.050.1 - -
- - 10 10 10 10 - - - - -
- - 334.012.3 334.016.3 334.020.3 334.026.3 - - - - -
- - 150 150 150 120 60 45 30 - -
- - 334.012.5 334.016.5 334.020.5 334.026.5 334.035.5 334.040.5 334.050.5 - -
1/4 5/16 3/8 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3
- - M16/M20 M20 M25 M32 M40 M50 M63 - -
- - 11/13,5 16 21 29 36 42 48 - -
- - 1/2 1/2 3/4 1 1 1/4 1 1/2 2 - -
EMP SHIELDING (MEOB.96_049 ELM)
Frequency (MHz)ShieldingE
ffectiveness
(dB)
Z.H.U.A.: UL & halogen f ree
Type Z.H.U.A. is the ultimate Anaconda Sealtite conduit with integral grounding
copper wire (till 1.1/4"). The Z.H.U.A. is UL approved and has a wide temperature
range. Because of the integrated copper grounding wire the Z.H.U.A. also offers a fine
EMI/EMP shielding, which makes it useable for applications where a high degree of
electrical continuity is required. Another unique feature of the Z.H.U.A. is, that it isextremely flexible at both high as low temperatures. The Z.H.U.A. is often being
applied in the subway, train and bus-building industry, in closed areas, airports, tunnels
and (subway) stations. Especially for exportprojects outside Europe.
Construction : Galvanized steel core, square-locked with integral copper
grounding wire, thermoplastic cover (Polyurethane,
compound). From 1 1/2 a fully inter-locked profile
will be used.
Cover specifications: Polyurethane, sunlight and UV resistant, suitable for
outside installation. The cover is good resistant against
oil and greases.
Special approvals : UL-360 (file #E18917) material classification V0 - UL94.
Temperature : -45C to +80C, intermittent up to +100C.
Colour : Black.
A N A C O N D A S E A L T I T E c o n d u i t t y p e Z . H . U . A .
Sealt ite type Z.H.U.A.Special remarks:
* All sizes ZHUA are no stock item, please notice a delivery time of 6 till8 weeks.
* Larger sizes 2 1/2 till 4 available on demand.* Approved as earthconnector if length is max. 1,5 meter (see UL 360)
* Complies with NEC sect. 351 A.
* Suitable to use in hazardous environments according NEC 501-4B
Class I, Division 2; Class II, Division 1 and 2; Class III, Division 1 and 2.
EN 50086 Classification Value Description
Compression resistance 4 Heavy (1250 N)
Impact resistance 4 Heavy (6 J)
Minimum temperature 5 -45C
Maximum temperature 1+ +80C
Bending resistance 4 Flexible
Electrical proporties 3 With continuity and
insulating characteristics
Resistance to ingress of solid 6 Protected against dust
foreign objects (I) (dustproof)
Resistance to ingress of 7 Watertight
water (P) (1 meter deep, 30 min.)
Corrosion resistance 3 Medium / High
inside / outside
Tensile strength 4 Heavy (1000 N)Resistance to flame 1 Non-flame
propagation propagating
Suspended load capacity 0 None declared
Square-locked profile
Trade s ize ZHUA In c h
Fi t t i n gs ISO
PG
NPT
Ins ide diameter mm
Outs ide diameter mm
B en di ng radi us s tat ic mm
(cen ter l in e) dynamic mm
Standard car ton m
A rt ic le N o. b lac k
Small car ton m
A rt ic le N o. b lac k
Reels m
A rt ic le N o. b lac k
The sui table f i t t ings and accessor ies for Sealt i tetype Z.H.U.A. are ment ioned on pages 34 t i l l 47.
-
7/27/2019 Download Electrical Catalogue
34/72
3 4
M12x1,5 M16x1,5 M16x1,5 M20x1,5 M20x1,5 M25x1,5 M32x1,5 M40x1,5 M50x1,5 M63x1,5
1/4 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
5,2 8,3 10,2 10,2 13,9 18,5 23,8 31,8 36,8 47,8
33 35 35 36 37 40 46 52 56 66
10 12 12 13 13 15 15 16 18 20
22 26 26 26 29 35 45 54 63 77
20 24 24 24 27 33 43 52 60 74
50 50 50 50 50 25 10 5 5 4
812.012.1* 812.015.1* 812.016.1 812.017.1 812.020.1 812.025.1 812.032.1 812.040.1 812.050.1 812.063.1
1/4 5/16 3/8 3/8 1/2 3/4 1 1 1/4 1 1/2 2
M12 M16 M16 M20 M20 M25 M32 M40 M50 M63
7 9 11 13,5 16 21 29 36 42 48
- 1/2 1/2 1/2 1/2 3/4 1 1 1/4 1 1/2 2
- M16x1,5 M16x1,5 - M20x1,5 M25x1,5 M32x1,5 - - -
- 5/16 3/8 - 1/2 3/4 1 - - -
- 8,3 10,2 - 13,9 18,5 23,8 - - -
- 41 41 - 43 48 54 - - -
- 12 12 - 13 15 15 - - -
- 26 26 - 29 35 45 - - -
- 24 24 - 27 33 43 - - -
- 50 50 - 50 25 10 - - -
- 813.015.1 813.016.1 - 813.020.1 813.025.1 813.032.1 - - -
- M16x1,5 M16x1,5 M20x1,5 M20x1,5 M25X1,5 M32x1,5 M40x1,5 - -
- 5/16 3/8 3/8 1/2 1/2 3/4 1 - -
- 4-8 4-8 6-10,2 6-12 10-13,9 13-18 18-23,8 - -
- 57 57 57 59 62 70 83 - -
- 12 12 12 12 12 15 15 - -
- 26 26 26 29 29 35 45 - -
- 24 24 24 27 27 33 43 - -
- 18 18 22 22 27 34 43 - -
- 25 25 25 25 25 25 10 - -
- 812.715.1 812.716.1 812.717.1 812.720.1 812.722.1 812.728.1 812.735.1 - -
A
B
E (SLW)
C
AB
E (SLW)
C
E (SLW)
E (SLW)
A
B
F (SLW)
C
A N A C O N D A F I T T I N G S f o r S E A L T I T E , I P 6 7
ISO straight cable-hose-f it t i ng, male, nickel plated br ass
ISO strai