Philosophy
Lab Systems & Biotech (I) Pvt.Ltd., pioneers in spectroscopy field since last 30 years with its rich core competency in sales & support of spectroscopic analytical instruments is proud to introduce a very powerful, rugged, reliable yet economical and very
plus easy to use true double beam UV VIS spectrophotometer Model LAB UV 3000 PC.
plus LAB UV 3000 PC spectrophotometer with its wide sample compartment accommodates various accessories like multi cell holder, micro cell holder, solid sample holder, thermostated cell holder, variable path length cell holder, sipper system, etc to cater wide range of applications in the field of pharmaceuticals, life sciences, chemicals, petrochemicals, agriculture, food & beverages, environmental, clinical & diagnostics, educational institutes as well as quality control, research & development laboratories.
We believe that there is neither greater compliment nor there is a greater asset than a company can have a truly satisfied customer. We value your suggestions, appreciate your recommendations and give them serious consideration. We value your views as our customer because our goal is customer satisfaction.
We achieve this goal through a combination of quality of innovative products and dedicated technical staff.
We believe, we have many satisfied & reputed customers. We can name a few like Ajanta Pharma, Akriti Pharma, Adley Pharma, Admac Pharma, Aarti Drugs, Alkem Laboratories, ARAlL Ankleshwar, Analab, Apar, Abbott, Aptuit Laurus, Amoli, Aristo, Bayer, Bee Pharmo Testing Lab., Biochem, Biomab, Bombay Tablet, BARC, Cachet Pharma, Citochem, CSIO, CFTRI, CAT, Cheminnova, CEERI, Cipla, Cadila, Clariant, Ciron, Coral, Choksi Lab, Dishman, Dr. Reddys Lab., Deepak Fertilizer, Diamond Dyechem, Dabur, Enicar Pharma, Emcure, Elder, EthyPharm, FDC, Forensic Science Lab., Griffon, Gelnova, Haffkine Institute, Hetero, Hikal, Hexa Analytical Lab, ICPA Health Care, Indchemie, Impulse Pharma, Invochem Laboratories, ITC, Intas, Ipca, Jayco Chemicals Ind., Kopalle Pharma, KEM Hospital, Lupin, Maxwell Lifescience, Mankind, Matrix-Mylan, Maneesh Pharma, Medinex, M.J.Lab, Mumbai University, NIO-Goa, NIPER, Oscar Labs, Olive Healthcare, Orchid, Okasa, Plethico, P&B Pharma, PERD Centre, Pricise Pharmachem, Promed, Pharmasolve, Ranbaxy, Rubicon, Ratio Pharm, Raptakos Brett Test Laboratories, Rusan, RCA Lab, Sun Pharma, Saphire Lifescience, Sitec, Svizera, Srikem, Strides Arco, Symbiotec, Shreya Lifesciences, Sri Krishna Keshav, Transpek Ind., Torrent,Tulip,Tirupati Life Sciences, Textiles Committe, UICT, Venus Remedies, Vapi Care, VVC Pharma, Wockhardt, Wyeth, Zydus Cadila Pharma, Zibran Pharma, Zeiss Pharma, Etc.
We thank all our valued customers for trust and co-operation in working with our company and making it what it is today and will be in future.
We have state of the art, full range of analytical instruments complying 21 CFR Part 11 as required by regulatory authorities like US FDA, EP, BP, TGA, DAB, MHRA, JP Pharmacopoeias along with IQ/OQ/PQ documentation.
Our well qualified and factory trained engineers and application specialists are always eager to respond quickly and efficiently to the need at our customers.
INTERNAL DESIGN
Technical Specifications:
The two detectors measure sample and reference
light respectively and simultaneously for
optimizing measurement accuracy. It provides
excellent performance for measurements in the
range of 190 to 1100 nm. It is suitable for
pharmaceutical, biochemical and clinical lab
applications as well as routine applications such as
quantitative analyses, kinetics, wavelength scan,
multiple components and DNA/Protein. UV VIS
Analyst software makes this instrument versatile.
It provides excellent performance for
measurements.
SALIENT FEATURES :
• True Double Beam with 1nm fixed bandwidth.
• Fixed bandwidth for reproducible results.
• High quality Silicone Photo-diode detectors.
• In Stand-alone mode, all software methods are
included as built-in standard; this eliminates
the need of software.
• On line display of UV and visible lamps life on
the screen at a glance.
• The status of the lamps life ensure that the user
can change lamps conveniently.
• I
• Online software upgrade via internet helps to
keep it updated.
• Data Download to PC software expands the data
storage to unlimited.
• Pre-aligned Deuterium and Halogen lamp for
easy lamp replacement.
• Built-in self check and auto Diagnostics facility.
• Buit-in System Validity.
• Complies EP/BP/USP Pharmacopoeia test for
Stray Light, Resolution, etc.
ncludes windows based application software.
Model
Wavelength Range
Spectral Bandwidth
Optical System
Grating
Wavelength Accuracy
Wavelength Repeatability
Wavelength Display / Setting
Wavelength Scanning Speed
Wavelength Scanning Step
Photometric Range
Photometric Accuracy
Photometric Repeatability
Photometric Baseline Stability
Photometric Baseline Flatness
Photometric Noise
Stray Light
Measuring / Scan Ordinate Modes
Operation Mode
Display
Sample Compartment
Detector
Light Source
Output
Power Requirement
Dimension
Weight
Additional Software Module
Environmental Requirement
Data Download to PC
plus LAB UV 3000 PC
190 nm - 1100 nm
1.00 nm Fixed Over Entire Range
True Double Beam
Holographic with 1200 Lines/mm
±0.1 nm - UV Region
±0.1 nm @ 656.1 nm D2 line
±0.3 nm - Visible Region
±0.1 nm – Over Entire Range
±0.1 nm - Increment
HI,MED,LOW,VERY LOW (3000-1 nm/min)
0.1 – 5.0 nm
-0.4 Abs to +4.0 Abs., 0-400% T
±0.001 Abs @ 0.3 Abs
±0.002 Abs @ 0.5 Abs
±0.004 Abs @ 1.0 Abs
±0.006 Abs @ 2.0 Abs
±0.001 Abs @ 0.3 Ab
±0.001 Abs @ 0.5 Abs
±0.001 Abs @ 1.0 Abs
±0.003 Abs @ 2.0 Abs
≤0.0002 Abs/Hr @ 500nm, (After 1hr warm-up)
±0.0005 Abs Over Entire Range
≤0.00005 Abs RMS @ 500nm
<1.0 %T KCL @ 198nm,
<0.02 %T Nal @ 220nm,
<0.02 %T NaNO2 @ 340nm
Absorbance (Abs), Percent Trans (% T) & Conc. (C).
Stand-alone & PC Control.
5" Large LCD Screen – (320 X 240 Pixels)
W-155mm X D-250mm X H-115mm
High Quality Dual Silicon Photodiodes
Pre-aligned Tungsten & Deuterium Lamps
USB Port for PC & Parallel Port for Printer
AC-110/220V, 50/60-Hz
L-24" X D-18" X H-8"
20 Kg.
Kinetic and DNA/Protein
Temp. : 20°C - 35°C, Rh. : 20% - 85 %
Through licensed version UV Vis Analyst software
plus LAB UV 3000 PC
LAB UV Local Control Softwareplus 3000 PC All methods are included as built-in standard; this eliminates the
need of software & online software update via Internet.
The local control software includes functions such as:
Photometry, Quantitative, Wavelength Scan, Kinetics.
DNA/Protein, Multi-Wavelength Test and System Utilities.
WL: 500.0 nm 08:00:00
Cancel Move Dn Select
D2
WLAB
Main Menu
Basic Mode
Quantitative Mode
Wavelength Scan
Kinetics Mode
DNA/Protein Mode
Multi-Wavelength Mode
System Utility
1
2
3
4
5
6
7
WL: 500.0 nm 08:00:00
Method Standard Show Curve
D2
WSetup Standard Conc.
ID
1
2
3
4
Params
WL (nm)500.0
Search
Conc. (ug/uL)
1.000
2.000
3.000
Abs.
4.000
Up to 10 standard solutions may be used to establish calibration
equation curve. There is a choice of four methods for fitting
curve through the calibration points: Linear fit, Linear fit
through zero, square fit and cubic fit.
Standard Curve
WL: 500.0 nm 08:00:00
100.5
Abs.
0.0
000
230.0 Wavelength (nm) 650.0
Setup Mode Search Smooth
D2
W
Start WL680.0 nm
End WL200.0 nm
X Scale
Y Scale
Interval1.0 nm
The Wavelength Scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and
High, Medium and Low scan speeds are available. Scan speeds
vary from 100 to 1000 nm/min. Wavelengths are scanned from
high to low so that the instrument stand-by at high wavelength.
This minimizes the degradation of UV sensitive samples. Precise
control of filter and lamp changes means that their effects are
not seen on the final scan. Post-run manipulation includes re-
scaling axes, curve tracking and peak picking.
Wavelength Scan
WL: 500.0 nm 08:00:00
100.5
%T
99.5
0 Time 180
Setup Mode Smooth Search
D2
W
Total180s
Interval1s
X Scale
Y Scale
This mode may be used for time course scanning or reaction rate
calculations. Abs Vs Time graphs is displayed on the screen in real
time.
Wait time and measurement time up to 12 hours may be entered
with time intervals of 0.5, 1, 2,5, 10, 30, seconds and 1 min. Post-run
manipulation includes re-scaling, curve tracking and selection of
the part of the curve required for the rate calculation. Rate is
calculated using a linear regression algorithm before multiplying by
the entered factor.
Kinetics
WL: 400.0 nm 08:00:00
WL Setup
D2
WSetup Standard Conc.
ID
1
Mode
WL (nm)500.0
Search
Conc. (ug/uL)
200.0
300.0
400.0
Abs.
2.322
2.123
2.034
Scroll
Up to 10 wavelengths may be entered, allowing the measurement of
multiple wavelengths on a series of Samples.
Multi-Wavelength
WL: 320.0 nm 08:00:00
Coeff
D2
WDNA / Protein Test
No.
Method
WL (nm)260.0280.0320.0
Items
A1
A2
Aref
C-DNA
C-Pro
Ratio
Unit
Abs
Abs
Abs
ug/UL
ug/UL
Result
0.251
0.243
0.095
4.524
110.8
1.059
Unit Default
Concentration and DNA purity are calculated Absorbance ratios at
260nm/280nm or 260nm/230nm with optional subtracted
absorbance at 320nm.
DNA Concentration = 62.9*A -36.0*A Or 49.1*A -3.48*A260 280 230
Protein Concentration = 1552*A -757.3*A Or 183*A -75.8*A260 280 260 230
Other wavelengths and factors may be entered.
260
DNA/Protein Test
plus LAB UV 3000 PC
UV VIS Analyst Software for LAB UV plus 3000 PC
The Windows based PC application software UV VIS Analyst takes
the best features of the stand-alone version plus more powerful
data processing, expanded data collecting, and storage pluscapability. It is standard with LAB UV 3000 PC model and is
optional to stand-alone model.
The UV VIS Analyst software offers:1 . Photometric Mode
2. Quantitative Test (standard curve)
3. Wavelength Scan
4. Kinetics
5. DNA/Protein
6. Multi-Wavelength
7. System Utility
Use up to 20 standards to establish standard curve. Four
methods for fitting a curve;
1. Linear fit
2. Linear fit through zero
3. Square fit
4. Cubic fit
Quantitative Test (Standard curve)
Automatically records peaks and valleys. The quantity of
spectra is unlimited; you can simultaneously store as many
as desired. Post-run manipulation and processing includes:
1. Re-scaling axes, curve
2. 1st to 4th derivative
3. Smoothing, combination, zooming, overlap
Wavelength Scan
Kinetics (Abs Vs Time)The Kinetics mode may be used for time course scanning or
reaction rate calculations. Abs Vs Time graphs are displayed on
the screen in real time. Waiting time, measurement time and
time intervals may be entered. Post-run manipulation includes
re-scaling, curve tracking and selection of the part of the curve
required for the rate calculation. Rate is calculated using a
linear regression algorithm before multiplying by the entered
factor.
DNA/ProteinConcentration and DNA purity are quickly and easily calculated:
Absorbance ratios at 260nm/280nm with optional subtracted
absorbance at 320nm.
DNA Concentration = 62.9*A -36.0*A260 280
Protein Concentration = 1552*A -757.3*A260 280
Other wavelengths and factors may be entered.
Multi-WavelengthUp to 20 wavelengths can be selected and multiple samples can
be measured. (Auto cell changer is required to run multiple
samples automatically)
plus LAB UV 3000 PC
4-CELL HOLDER FOR 10mm- CUVETTERECTANGULAR
4-CELL HOLDER FOR UP TO 50mm- CUVETTERECTANGULAR
4-CELL HOLDER FOR UP TO 100mm- CUVETTERECTANGULAR
CYLINDRICAL CELL HOLDER
WATER-JACKETED CELL HOLDER
MICRO CELL HOLDER
TEST TUBE HOLDER
8-POSITION AUTO CELL CHANGER
SOLID SAMPLE HOLDER (SINGLE CELL)
10mm WATER-JACKETED 4-CELL HOLDER
Optional Accessories
CONST. TEMP. PELTIER SIPPER SYSTEM
CONST. TEMP. PELTIER SYSTEM
AMBIENT SIPPER SYSTEM
THERMAL PRINTER
DEUTERIUM LAMP
RECTANGULAR CUVETTES-GLASS/QUARTZ
MICRO CELL-QUARTZ
SEIF MASKING CONT. FLOW THROUGH GLASS/QUARTZ CELL
HOLMIUM OXIDE FILTER
HALOGEN LAMP
100
200
500
µlµlµl
10mm20mm30mm50mm
100mm
5mm10mm20mm30mm
Optional Accessories
329, Mastermind IV, Royal Palms, Aarey Milk Colony, Goregaon (East), Mumbai-400 065, India.Tel.: ++91-22-3251 4134, Telefax :++91-22-28794637/36, Website : www.labsystems.inE-mail : [email protected]/[email protected]
:BRANCHES:
Baroda, Indore, Baddi, Goa, Hyderabad, Chennai
:Authorised Representative:
S u p p o r t B e y o n d S e r v i c e sNote : Lab Systems & Biotech (I) Pvt. Ltd. reserves the right to change specification without notice.
Range of Products