Dosimetry Radiation Safety Program This module meets the annual re-training requirement per...
-
Upload
deanna-barnish -
Category
Documents
-
view
215 -
download
0
Transcript of Dosimetry Radiation Safety Program This module meets the annual re-training requirement per...
DosimetryRadiation Safety Program
This module meets the annual re-training requirement per Environment, Health and Safety’s Radiation Safety Program Policy. Use the buttons to navigate through the module.In order to receive credit for reviewing this module, please follow the instructions at the conclusion of the slides.
Slide 2
Objectives• Identify the biological effects when ionizing
radiation interacts with the human body.• Differentiate between various types of
dosimetry. • Identify UCLA dosimetry policies, including
proper badge usage.• Define radiation dose units and how they
relate to annual dose limits set by the Nuclear Regulatory Commission (NRC).
Slide 3
Radiation BiologyTo understand the purpose and function of dosimetry we must first understand the risks associated with working with radiation.How does radiation affect our bodies?• Ionizing radiation transfers energy to
electrons• Ionizing radiation has sufficient energy
to break chemical bonds• Broken water molecules lead to free
radicals which are chemically reactive • At the cell level, single and double
strand breaks in DNA caused by ionizing radiation may lead to mutations, carcinogens, and cell death
DNA Single Strand break
DNA Double Strand break
Slide 4
Biological Effects
Biological effects from radiation can be broken down into two types:• Deterministic effects, which
only occur above a certain dose threshold• Stochastic effects, which have
a chance of occurring at any range of dose
Slide 5
Stochastic EffectsWhether you are working in a research or clinical environment, nearly all exposure to radiation will be at low doses, where stochastic effects can still occur.
A recent analysis of epidemiological studies of atomic bomb survivors, nuclear workers, and persons exposed to radiation for medical reasons predicts:
Approximately 42% of the population will be diagnosed with cancer from causes unrelated to radiation exposure.
A radiation dose of 10 mSv (1 rem) will increase the risk of developing cancer by 0.11% and fatal cancer by 0.056%1
1National Academies Council on Biological Effects of Ionizing Radiation (BEIR) VII.
Slide 6
Deterministic Effects• Deterministic Effects have a threshold, meaning that only
above a threshold dose do these effects occur. The occupational limits of radiation exposure are well below any deterministic effect threshold.If absorbed dose
is greater than:Possible Skin Effect
Could be:
2 Gy transient erythema (reddening of skin
6 Gy erythema
3 to 5 Gy temporary epilation (hair loss)
7 Gy epilation can be permanent
10 Gy dry desquamation (skin shedding)
15 Gy moist desquamation
Slide 7
Scenario 1: What do you think?Mark is about start working in a lab that works with P-32 to label DNA. As is typical with DNA labeling, Mark will be receiving low doses of radiation. Which effects should he be concerned with?
1. Both, deterministic and stochastic.
2. Deterministic effects.
3. Stochastic effects.Click here to see
the correct answer…
Slide 8
Scenario 1: What do you think?Mark is about start working in a lab that works with P-32 to label DNA. As is typical with DNA labeling, Mark will be receiving low doses of radiation. Which effects should he be concerned with?
1. Both, deterministic and stochastic.
2. Determinist effects.
3. Stochastic effects.
Correct! A laboratory worker that handles P-32 for DNA labeling is not at risk of exceeding the 2 Gy deterministic effects threshold. A typical badge reading from
a lab worker handling isotopes for DNA labeling is near background levels of radiation.
Slide 9
What is Dosimetry?
Dosimetry is the measurement of radiation dose received.
Dosimeters (e.g., badges, rings) measure the amount of radiation received by radiation workers and help Environment, Health and Safety monitor radiation dose to be sure workers do not exceed annual limits.
Badges and rings are administered to workers based on radioactive material shipment limits and/or specific radiation worker occupations.
Slide 10
Units of Dosimetry: Absorbed Dose
• Absorbed Dose (D): a measure of the amount of energy from ionizing radiation deposited in a material. Human tissue is an example of such material.
How much
dose did I get?
Energy in the form of radiation
• Traditional unit: Radiation Absorbed Dose (rad), 1 rad = 100 erg/g
• International unit: Gray (Gy), 1 Gray = 1000 joules/kg
• 1 Gray = 100 rads
Slide 11
Units of Dosimetry: Equivalent Dose• Equivalent Dose (H) is the absorbed dose (D) multiplied by a radiation
weighting factor (WR)
• H = D x WR
• Equivalent dose is a more accurate measurement (compared to absorbed dose) of dose because it takes into consideration the type of radiation irradiating the matter. Each radiation type (e.g., alpha, beta, gamma, neutrons, x-rays) has a different degree of effectiveness in producing biological effects, hence the use of a radiation weighting factor (WR).
• Traditional unit - Roentgen Equivalent Man (rem)• International unit - Sievert (Sv)
Radiation Type Weighting factor (WR)
Gamma-rays/ X-rays/ Beta particles 1
Neutrons 5-20
Alpha Particles 20
Slide 12
Units of Dosimetry: Effective Dose
• Effective Dose (E) is the equivalent dose (H) multiplied by a tissue weighing factor (WT)
• E = H x WT
• Effective dose is the most accurate measurement of biological damage because it takes into consideration the type of radiation and the type of tissue being irradiated.
• Traditional unit is the rem,• International unit is the Sievert (Sv)• The regulations are based on effective
dose
Tissue Type Weighing factor (WT)1
Bone marrow 0.12
Colon 0.12
Lung 0.12
Stomach 0.12
Breast 0.12
Gonads 0.08
Bladder 0.04
Esophagus 0.04
Liver 0.04
Thyroid 0.04
Bone surfaces 0.01
Brain 0.01
Salivary Glands 0.01
Skin 0.01
1From ICRP 103 (2008)
Slide 13
Annual Dose Limits
Per NRC regulations, if a radiation worker is likely to get 10% of the annual dose limits (shown on the right), they must be issued dosimetry.
Eyes0.15 Sv
(15 rem)
Extremities(below knees and
elbows)0.5 Sv
(50 rem) Internal Organs0.5 Sv
(50 rem)
Total Effective Dose
(whole body)0.05 Sv(5 rem)
Skin0.5 Sv
50 rem
Slide 14
ALARA Limits at UCLA
• UCLA has established its own, more stringent annual dose limits in order to keep doses As Low As Reasonably Achievable (ALARA).
• The EH&S Radiation Safety Program has ALARA I, II, and III limits, which represent 24%, 48%, and 96% of the NRC annual dose limits, respectively.
• If a dose is reported that exceeds the ALARA II or III limits, you will receive a notice from the Radiation Safety Program. EH&S will also investigate the matter to keep doses as low as reasonably achievable.
Slide 15
ALARA Limits Specific to UCLA
Area of Body (location of dose measurement)
ALARA I (mrem/ month)
ALARA II(mrem/ month)
ALARA III(mrem/ month)
Deep-Dose: whole body exposure (tissue depth of 1 cm) 100 200 400
Lens of Eye Dose: external exposure of the lens of the eye (tissue depth of 0.3 cm) 300 600 1200
Shallow/ Extremity Dose: external exposure of the skin or an extremity (tissue depth of 0.007 cm, averaged over an area of 1 cm2.)
1000 2000 4000
Fetal Dose: exposure of the fetus/embryo during the gestation period. 12 24 48
Look at the chart below to determine how much dose you can receive in different areas of your body per month, and how that relates to your ALARA limits.
Slide 16
Scenario 2: What do you think?
Sue works with F-18, her exposure report read 405 mrem to the whole body for the month of January which puts her over ALARA III limits under UCLA policy. What can she expect?
1. Nothing will happen, she is on pace to be under the annual limit of 5,000 mrem.
2. She will get a notice from the Radiation Safety Program.
3. Since she exceeded ALARA III limits, she will receive a letter that she can no longer work with radiation for the
rest of the year. Click here to see the correct answer…
Slide 17
Scenario 2: What do you think?
Sue works with F-18, her exposure report read 405 mrem to the whole body for the month of January which puts her over ALARA III limits under UCLA policy. What can she expect?
1. Nothing will happen, she is on pace to be under the annual limit of 5,000 mrem.
2. She will get a notice from the Radiation Safety Program.
3. Since she exceeded ALARA III limits, she will receive a letter that she can no longer work with radiation
for the rest of the year.
Correct! The Radiation Safety Program will be in contact with Sue to help minimize her dose by analyzing work practices.
Slide 18
Dosimeters• Dosimeters measure the amount of
radiation dose received by wearers. At UCLA, various types of dosimeters are used:
• Optical-Stimulated Luminescence dosimeters (OSL) • Thermoluminescent dosimeters (TLD)• Pocket dosimeters • Electronic dosimeters
Slide 19
Dosimeters: OSL BadgesOptical Stimulated Luminescence (OSL) badges measure whole body, lens of the eyes and shallow dose.
How are OSL Badges read?OSL badges contain aluminum oxide (Al2O3) crystals which are read by a specific wavelength of laser light. The released light indicates the amount of radiation dose.
OSL badge have limitations: • For x-ray, gammas only > 5 keV photons can be read, dose
measurement range of 1 mrem to 1000 rem• For beta particles only > 150 keV particles can be read, dose
measurement range of 10 mrem to 1000 rem.
Slide 20
Dosimeters: TLD RingsThermoluminescent dosimeter (TLD) rings assess extremity (e.g., below the elbow) doses.
How are TLD rings read?TLD badges have a lithium fluoride chip inside the engraved ring cover which when heated causes a luminescence in proportion to the amount of radiation exposure.
TLD rings have limitations: • For gammas, x-rays only >15 keV photos can be read, dose
measurement range from 30 mrem to 1000 mrem• For betas only > 200 keV particles can be read, dose measurement
range from 40 mrem to 1000 mrem• Affected by heat, moisture, and pressure, cannot be re-read, unlike
OSL badges.
Slide 21
Dosimeters: PocketPocket dosimeters, used by cyclotron users and in emergency situations, are issued less frequently. Pocket dosimeters allow for instantaneously dose analysis. How are pocket dosimeters read?Pocket dosimeters are read by pointing one end at a light source and observing the other end close to the eye.
Pocket dosimeters have limitations: • Type of Radiation that can be read: 20 keV to 2 MeV x-rays and gammas• Sample dose range 0 to 200 mR , 0 to 600 R
Slide 22
Dosimeters: Electronic
Electronic dosimeter are also issued less frequently than OSL and TLD badges, normally during emergencies.
How are Electronic Badges read?Electronic badges can be set to give a dose rate, sound a dose rate alarm, and provide instantaneous dose analysis.
Electronic badges have limitations: • Can give you total dose and total dose alarm• Sample measurement range 0.1 mrem to 999 rem• Sample energy range of 60 keV photos to 6 MeV
Slide 23
Proper Dosimetry Badge Wear
For Whole Body Badges:
• Worn on the part of the body between your neck and waist
• Wear it so name tag faces radiation source• If lead apron is worn, wear the badge at collar
level on the outside of apron
For Dual Badges:• One badge on the collar, outside lead
apron• One badge on the waist, under lead
apron
Slide 24
Proper Dosimetry Badge Wear• Wear your ring badge
with the white label on the same side as the palm of your hand.
• Remember, your palm is closest to the radioactive materials you are working with, so the badge should also be closest to the materials.
• If you are wearing a glove, wear your ring underneath the glove.
Slide 25
Responsibilities of Those Wearing Dosimeters • Store your dosimetry badge
in a non-radiation location when not in use
• Exchange your badge when requested by the Departmental Badge Coordinator
• Keep your badge at work. Don’t take it home
• Wear your dosimetry badge: • whenever using
radiation-producing machines or radioactive materials that present an external hazard
• for the current monitoring period
• in the correct location on the body
• If you are pregnant and wish to begin fetal monitoring, it is your responsibility to declare your pregnancy in writing to the RSP
• Never share your dosimetry badge or wear someone else’s
• Do not intentionally expose dosimeters to radiation
• Do not wear your dosimetry badge for non-occupational exposures
• Do not use your badge at an institution other than UCLA
Do’
s Don
’ts
Slide 26
Badge Exchange
1. EH&S automatically sends replacement badges to Department Badge Coordinators during the last few days of the month.
2. Department Badge Coordinators exchange your badge by collecting the used one and providing you with a new one. (Late badges will incur a $5-$11 fee.)
3. Dosimeters are returned to EH&S (by the Department Badge Coordinators) for processing.
4. EH&S mails all Dosimeters to an outside company for processing, and provides follow-up exposure reports to Department Badge Coordinators.
• Contact your Department badge coordinator or the Radiation Safety Program to view your dose report.
• Your radiation exposure history will be provided to you or your subsequent employers on request.
• If dose of “M” is reported, the total dose received was below the minimal detectable level.
Badges are exchanged on a monthly or quarterly basis for radiation exposure processing. Here’s how it works:
Reporting……
EH&S Radiation Safety maintains all exposure records indefinitely. Here are the important facts about reports:
Slide 27
Scenario 3: What do you think?
If a radiation worker becomes pregnant what should she do?
1. Declare her pregnancy in writing to the Radiation Safety Program if she wishes to begin fetal monitoring.
2. Immediately stop working with radiation.
3. Continue working, since she already has a radiation badge.
Click here to see the correct answer…
Slide 28
Scenario 3: What do you think?
If a radiation worker becomes pregnant what should she do?
1. Declare her pregnancy in writing to the Radiation Safety Program if she wishes to begin fetal monitoring.
2. Immediately stop working with radiation.
3. Continue working, since she already has a radiation badge.
Correct! There are safe levels of working with radiation under the guidance of the Radiation Protection Program. A separate fetal badge is issued to
keep track of the more stringent fetal dose limits.
Slide 29
Recording Your Completion Annual Refresher Training
Now that you have read through this annual refresher training module, be sure to record it on your laboratory’s Principal Radiation Worker Training Record Form. Beside your name, mark the “OL” box for online, date, and initial the form.
Slide 30
For more information
• Questions about the annual refresher training or need a copy of your lab group’s training form? Contact the your responsible health physicist or the Radiation Safety Training Manager at ext. 4-1876 or [email protected]
• Questions about topics discussed in this module? Contact the Dosimetry Program Manager at ext. 4-1742