DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1....

15
DORMA Installation Manual Keypad

Transcript of DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1....

Page 1: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

DORMA Installation ManualKeypad

Page 2: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

blank page

Page 3: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

Table of Contents

Table of Contents

1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

1.1 Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.2 Correct use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

1.� Safety instructions and warnings . . . . . . . . . . . . . 5

1.4 Further Source of Information . . . . . . . . . . . . . . . 6

1.5 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

1.6 Functional principle of the keypad . . . . . . . . . . . . . 6

1.7 Interfaces and protocol variants . . . . . . . . . . . . . . 6

1.8 Components supplied . . . . . . . . . . . . . . . . . . . . . . 7

1.9 Design of the keypad . . . . . . . . . . . . . . . . . . . . . 7

2 Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.1 Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.1.1 Installation regulations for the switch boxes . . . . . 8

2.1.2 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.2 Final assembly . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2.� Keypad connections. . . . . . . . . . . . . . . . . . . . . . . 9

2.�.1 Power supply . . . . . . . . . . . . . . . . . . . . . . . . . . 9

2.4 Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.4.1 DIP switch on the power supply board . . . . . . . . 10

2.4.2 DCW mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

2.4.� DP1 mode (RS485) . . . . . . . . . . . . . . . . . . . . . 11

3 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . 11

�.1 Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

�.1.1 Key functions of the keypad unit . . . . . . . . . . . . 12

�.2 Visual displays . . . . . . . . . . . . . . . . . . . . . . . . . 12

�.2.1 LED displays in the keypad unit . . . . . . . . . . . . 12

�.� Acoustic signals . . . . . . . . . . . . . . . . . . . . . . . . . 12

EU Declaration of conformity . . . . . . . . . . . . . . . . . . 13

4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Page 4: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 1. General information

44

The information provided in this installation guide may be modified without prior notification. All previous versions cease to be valid with the publication of this mounting guide.

The information in these assembly instructions has been compiled to the best of our knowledge and in good faith. DORMA Time + Access GmbH accepts no liability for the correctness or completeness of the information provided.

In particular, DORMA Time + Access GmbH cannot accept liability for any consequential damage due to incorrect or incomplete information.

The recommendations for installation provided in this man-ual are based on favourable basic conditions being present.

DORMA Time + Access GmbH accepts no liability for the perfect functioning of the keypad in environments outside the system.

Despite every effort to prevent mistakes, they can never be completely avoided. Therefore, we would be grateful to receive notification of any errors or omissions.

DORMA Time + Access GmbH accepts no liability for the information included in this document being free of pro-tected third-party rights.DORMA Time + Access GmbH does not provide any licences to its own or to third party patents or other protected rights with this document.

It is not permissible to print, reproduce or pass this manual, or parts thereof, to third parties, other than for your own use, without the approval of DORMA Time + Access GmbH.

All rights reserved.DORMA Time + Access GmbHPO box 21 01 855�156 Bonn, Germanyhttp://www.dorma-time-access.deE-mail: [email protected]

© Copyright 2007 by DORMA Time + Access GmbH

drawing no.: 1059G-00-B1as at: 01/11 V1.05

Page 5: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

5

1. General information

1.1 Preface

This installation manual is intended to assist you in connec-ting and commissioning the keypad. Information or drawings going beyond the content of this manual are available on request.

1.2 Correct use

This device is intended exclusively for use in time recording and access control systems. Further details are described in chapter 1.4. Any use other than that indicated is not permitted!

1.3 Safety instructions and warnings

This unit has been constructed and tested in accordance with the relevant current technical regulations. It left the factory in perfect condition in terms of safety and reliability. To maintain this condition and to ensure risk-free operation, the instructions and warnings given in this installation guide must be observed by the user.

• The device may only be used for the purpose intended by the manufacturer.

• Fitting and installation of electrical equipment may only be carried out by an electrician.

• Before opening the unit, always switch off the power sup-ply and check that it is inactive by measuring.

• During mounting, please ensure that the requirements laid down in the relevant equipment safety standard for the unit are adhered to since violating them could affect the safety of the device.

• Before switching on, ensure that the operating and con-trol voltages connected do not exceed the permissible values, in accordance with the technical data.

• This unit conforms to EN 60950-1 protection class III

Electromagnetic compatibility:• The unit is designed for use in residential, business and

commercial areas and conforms to EN 61000-6-2 and 61000-6-�.

• The PCB can be damaged by static electricity discharge, so the relevant precautionary measures must be observed (grounding etc.).

Caution

• These units may only be operated when mounted.

• The locking screws on unassigned connection terminals must be screwed in as far as they will go.

• If it must be assumed that danger-free operation is no longer possible, take the unit out of operation and secure it against accidental use.

• If there is a possible danger to people or animals or of damage to operating equipment due to the failure or malfunction of the unit, this must be prevented by taking additional safety measures (limit switches, safeguards etc.).

General Installation Guidelines see manual 1006G-B0

Page 6: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 1. General information

6

Depending on the firmware employed, the keypad always supports only one interface with a particular protocol.The interface and protocol supported can be seen from the type code on the nameplate.

The keypad is offered for use in DCW mode in two electroni-cally different versions.Either as a simple PIN keypad or as a PIN keypad with an integrated contactless reader for the secure identification of persons.The difference can be recognised by the description on the name plate.In the DP1 model there is always a reader.

Depending on the model, persons are identified by simply entering a PIN number or by holding an ID card in front as well. The electronics evaluate the data and send it to a superordinate control unit.The keys of the keypad are illuminated in the dark. A light sensor controls the background illumination.

1.6 Functional principle

KP-D-6-XX-PX10-DC-0-0-�-24V 20V-28VDC,max.0,96W XXXXXXXXXX-XXXXX-XXX XX

KP-D-6-XX-00-DC-0-0-�-24V 20V-28VDC,max.0,96W XXXXXXXXXX-XXXXX-XXX XX

with reader without reader

KP-D-6-XX-PX10-DC-0-0-�-24V 20V-28VDC,max.0,96W XXXXXXXXXX-XXXXX-XXX XX

KP-D-6-XX-00-DC-0-0-�-24V 20V-28VDC,max.0,96W XXXXXXXXXX-XXXXX-XXX XX

with reader without reader

1.7 Interfaces and protocol variants

ST1

02

5P

9�

EN

2N

1

KP-D-6-XX-XX-##-0-0-�-24V16V-�6VDC,max.1,2W XXXXXXXXXX-XXXXX-XXX XX

P1DC DCW

DP1DCW

RS485

Code Schnittstelle Protokoll

1.4 Further Sources of InformationFurther documents are available on request.

General Installation GuidelinesSpecifications for planning attendance recording and access control systems with our wired components.

Planner ManualExamples of cross-system solutions

Catalogues

1.5 DisposalThe device was manufactured using recyclable materials and components.When disposing of the device and the packaging, please ensure environmentally friendly recycling.

Information for EU CountriesEuropean Directive 2002/96 EC applies to this device. This means that this product must not be disposed of withnormal household waste. We, the manufacturer, will take back our electric and electronic products and dispose of them for you free of charge. Correct disposal of your old equipment protects people and the environment from possible harmful consequences.

Page 7: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

7

1. General information

1.8 Components supplied

A 1x keypadB 1x manual

B

DORMA Installation ManualKeypad

A

1.9 Design of the keypad

The keypad consists of a keypad unit and the power supply unit.

The power supply unit consists of an assembly board and a power supply board. The assembly board is for securing the unit in the switch terminal box. It holds the power supply board. The power supply board creates the voltage required internally from the power supply and provides the connec-tion to the DP1/DCW bus.

The keypad unit includes the keys with background illu-mination and the complete control system. It is mounted on the power supply unit. The electric connection is made through a knock-out section in the mounting board to a plug on the power supply board.

The device is delivered without a combination frame.In this way, users can use a frame from the respective range of switches suiting their own series.

Power supply unit

Keypad unit

Page 8: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 2. Installation

8

2.1 Preparation

The keypad must be mounted in a sheltered environment, i.e. within a closed room.

Because of the contactless ID card reading process, there must not be any metallic objects within a square area meas-uring 120 mm x 120 mm and with a depth of �0 mm.Appropriate distances must be ensured when planning and installing. The reading range will be reduced if it is not pos-sible to comply with these distances.

To prevent interference from both sides, two readers may not be installed closer to each other than the minimum specified distance.This minimum distance depends on local conditions.It should always be greater than 50 cm.

The wiring for the connections should be made in advance.

2.1.1 Installation regulations for the switch boxesFlush-fit switch boxes must not lie more than 4 mm beneath the surface of the wall or the plaster and must be positioned vertically in the wall. The front edge must be parallel to the wall surface or only deviate by a maximum of 1.5 mm. Flush-fit boxes that are not correctly mounted must be removed and re-mounted.

2.1.2 WiringDue to the connection terminals, only lines with a max. cross-section of 1 mm² can be connected.Twisted pair cables with a characteristic impedance of 120 Ω are to be used for the data lines.Detailed information about types and lengths of the cables as well as further information about planning access control systems with our components are contained in the General Installation Instructions Series 6. (Part no. 1900004912��6)

2.2 Final assembly

The keypad is delivered fully assembled. To connect it, first remove the keypad unit by simply pulling it off.

Before installing the power supply unit, please connect the two DP1/DCW plug connectors ST101 and ST104 to the power supply board (see page 8).After positioning correctly, the power supply unit can be inserted into the box and fixed in place with the screws.

The combination frame is positioned between the fitted power supply unit and the keypad unit. Then connect the keypad unit. Please make sure that the plug connection has been made correctly.

Please note: Before taking into operation for the first time, you must configure the address before con-necting the keypad unit.

Please note: The keypad has no built-in tamper detection. Instead, the software monitors the online sta-tus and detects whether the keypad unit has been removed.

28

min. 40

Page 9: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

9

2. Installation

2.3 Keypad connections

2.3.1 Power supplyThe power supply to the keypad is connected to terminal 1 and terminal � of the ST101. ST104 serves as the connec-tion for other bus devices.The pin assignment of ST101 is identical to ST104.The voltage must lie in the range of 16 V to �6 VDC.

Warning: Ensure that the system current1) is not higher than the admissible total current of the power supply unit employed.

1) System current = Sum of all currents drawn from the power supply unit or super ordinate control unit.

2.3.2 Communication interfacesThe function of the communication interface depends on the firmware employed (see section 1.5).

DCW busThe DCW bus line is connected to the connection terminals ST101 and ST104, signals A and B.

RS485 bus (DP1)The RS485 connection is identical with the DCW connec-tion.

3B

A1

1A

B3

ST10

4 ST101

0V

24V

AB

DP1/D

CW b

us

3B

A1

DP1/D

CW

ST10

1

3B

A1

DP1/DCW

ST104

24V

0V

ABOther bus

3B

A1

1A

B3

ST10

4 ST101

0V

24V

AB

DP1/D

CW b

us

3B

A1

DP1/D

CW

ST10

1

3B

A1

DP1/DCW

ST104

24V

0V

ABOther bus

Page 10: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 2. Installation

10

2.4 Settings

Preface: The settings, operation and displays are depend-ent on the configuration in the access control system. The status conditions described here reflect the normal status of the access control system on delivery.

2.4.1 DIP switch on the power supply boardThe DP1/DCW bus address can be set with the 2-pin DIP switch (accessible from the front of the power supply unit).

Please note: If the keypad is already connected, the key-pad unit can be raised slightly with a screw-driver or similar object and pulled off. SW101

ST101

IC1

02

P102

P101

23

1

schild

Baugruppen-

angabeSoftware

Sabotagelichtschranke

ST101

Online RelaisDigitale Eingänge

21 312

SW101

2.4.2 DCW mode

Switch 101

1 2 3 4 5 6 7 8

Functionality Bus adress Not used Reading process 1) Bus connectionresistor

Default off off on off off off off off

adjustable x x x

Address (decimal)

00 off off

1) Reading process only with DCW reader01 on off

02 off on

0� on on

Switch 101 Reading variants

4 5 6 Keypad

off off off Combined (Hitag1, Hitag2, EM4102, EM4450)

off off on not permitted

off on off Hitag2

off on on EM4450

on off off Hitag1

on off on EM4102

Page 11: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

11

2. Installation

2.4.3 DP1 mode (RS485)

Switch 101 Function in RS485 mode

1 2 3 4 5 6 7 8

Functionality Bus address Not used Bus connection resistor

Default on off off off off off off off

adjustable x

Address (decimal)

00 off off off off off

01 on off off off off

02 off on off off off

0� on on off off off

04 off off on off off

05 on off on off off

06 off on on off off

07 on on on off off

08 off off off on off

09 on off off on off

10 off on off on off

11 on on off on off

12 off off on on off

1� on off on on off

14 off on on on off

15 on on on on off

16 off off off off on

17 on off off off on

18 off on off off on

19 on on off off on

20 off off on off on

21 on off on off on

22 off on on off on

2� on on on off on

24 off off off on on

25 on off off on on

26 off on off on on

27 on on off on on

28 off off on on on

29 on off on on on

�0 off on on on on

�1 on on on on on

Page 12: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 3. Commissioning

12

3.1 Keypad

3.1.1 Key functions of the keypad unit (only DCW)The keys are only used for entering a PIN (max. 8 digits). Incorrect entries can be deleted with the * key (complete entry). After completing the entry, the number can be trans-mitted to the access control system with the # key.If neither of the two keys is pressed within 5 seconds, the complete entry is deleted and a short acoustic signal sounds.

In DP1 mode - no restriction to 8 digits. * and # keys can be allocated freely by the system.

3.2 Visual displays

3.2.1 LED displays in the keypad unitThe yellow status LED, on the left in the keyboard unit, is lit while the keypad is online. It goes out if it is not polled for longer than 7 seconds (DP1) or 15 seconds (DCW).

The right bicolour LED shows the access identification. Ita) flashes briefly in orange when an ID card is read. This

function is independent of the communication with an access control system.

b) lights green if the authorisation is identified.c) flashes green for 10 seconds if a PIN is demanded in

addition to the ID card identification. The PIN must be entered within this time.

d) lights red for 1 second if an ID card is read and identi-fied as unauthorised.

Points b) to d) can be changed in DP1 mode

3.3 Acoustic signals

a) A short key click sounds when a key is pressed in the keypad unit.

b) The buzzer sounds for 1 second with a continuous tone when the authorisation is identified.

c) The buzzer sounds intermittently for 1 second if access authorisation is not granted.

(Points b) and c) can be changed in DP1 mode).

Status LED

ID card identification

Light sensor

Page 13: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCWEG KonformitätserklärungEC Declaration of ConformityCE Déclaration de conformité

1�

Page 14: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW 4. Technical data

14

Technische Daten

Versorgungsspannung16 V bis �6 V DC (SELV)

Leistungsaufnahme max. 40 mA bei 24 V, max. 0,96 W

Leseabstandmax. 6 cm(bei Geräte mit integriertem Leser)

Sende-FrequenzHITAG: 125,00 kHz

SchnittstellenDCW-Bus oderRS485-Bus (DP1)

Anzeigeelemente1x LED (online)1x LED (read, Status PIN-Eingabe)1x Akkustischer Signalgebe

Betriebstemperatur –20°C bis +50°C (keine Betauung zulässig)

Lagertemperatur–20°C bis +70°C

Allgemeine AuslegungEN 60 950-1, Schutzklasse III

SchutzartIP �0

StörfestigkeitEN �01 489-�

StöraussendungEN �00 ��0EN �01 489-1, -�

AbmessungB71 x H71 x T24

Gewicht68 g

Technische Änderungen und Verbesserungen, die dem Fortschritt unserer Geräte dienen, behalten wir uns vor.

DORMA Time + Access GmbH Postfach 21 01 85 • D-5�156 Bonn • Mainzer Straße �6-52 • D-5�179 Bonn Tel. +49 (0) 2 28/85 54-0 • Fax +49 (0) 2 28/85 84-1 75 • www.dorma-time-access.de

DORMA GmbH + Co. KG Postfach 40 09 • D-58247 Ennepetal • DORMA Platz 1 • D-58256 Ennepetal Tel. +49 (0) 2� �� / 79�-0 • Fax +49 (0) 2� �� / 79 �4 95 • www.dorma.com

Page 15: DORMA Installation Manualproducts.dorma.com/content/download/6012/51073... · Keypad-DP1/DCW 1. General information 6 Depending on the firmware employed, the keypad always supports

Keypad-DP1/DCW

15

Notice