CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 300Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-300-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
29 5/16 in [74.4 cm]
11 1/16 in [28.1 cm]
22 1/8 in [56.2 cm]
4 7/16 in [11.3 cm]
31 7/8 in [81.0 cm]
7 1/2 in [19.1 cm]
Ø6"
5 3/16 in [13.2 cm]
2 1/2" WATER(2 PLCS.)
Ø3/4"NAT & LP
5 in [12.6 cm] 6 in
[15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
27 3/16 in [69.1 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
10 7/8 in [27.6 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
29 5/16 in [74.4 cm]
11 1/16 in [28.1 cm]
22 1/8 in [56.2 cm]
4 7/16 in [11.3 cm]
31 7/8 in [81.0 cm]
7 1/2 in [19.1 cm]
Ø6"
5 3/16 in [13.2 cm]
2 1/2" WATER(2 PLCS.)
Ø3/4"NAT & LP
5 in [12.6 cm] 6 in
[15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
27 3/16 in [69.1 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
10 7/8 in [27.6 cm]
CENTER OFGRAVITY
RSUB-27-D
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 300Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 3.8*
Input BTU/hr. 300,000 / 88 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 250,500 / 73 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 416 lbs. / 189 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell VR8304 3/4" Pilot Valve Honeywell VR8304
Firing Valve Honeywell B200T1025 3/4" Air Switch Cleveland RSS-495
Ignition Control UTC 1003-61A Blower Motor 1/5 hp - FLA 3.0
High Limit Honeywell L4008E Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Relief Valve - DB 3/4" x 3/4" set @ 50 psi
Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 38.0 Sq. Ft. / 3.53 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 3.5 gal / 13.2 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP15°F / 8.3°C 20°F / 11.1°C 25°F / 13.9°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
33.4 2.1 0.21 0.6 25.1 1.6 0.12 0.4 20.0 1.3 0.08 0.2
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-300-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
723 2733 482 1822 361 1366 289 1093 241 911 207 781
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 400Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-400-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-28-D
15 3/8 in [39.1 cm]
15 in [38.1 cm]
3 13/16 in [9.7 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
5 in [12.6 cm]
29 5/16 in [74.4 cm]
14 5/16 in [36.4 cm]
28 5/8 in [72.7 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø6"
5 3/16 in [13.2 cm]
Ø3/4"NAT & LP
6 in [15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
33 11/16 in [85.6 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
19 1/16 in [48.4 cm]
14 1/16 in [35.7 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
3 13/16 in [9.7 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
5 in [12.6 cm]
29 5/16 in [74.4 cm]
14 5/16 in [36.4 cm]
28 5/8 in [72.7 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø6"
5 3/16 in [13.2 cm]
Ø3/4"NAT & LP
6 in [15.2 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
33 11/16 in [85.6 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
19 1/16 in [48.4 cm]
14 1/16 in [35.7 cm]
CENTER OFGRAVITY
Dominator 400 model water heater not available for sale in the U.S. market due to DOE regulations.
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 400Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 3.8*
Input BTU/hr. 399,000 / 117 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 339,150 / 99 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 490 lbs. / 222 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell VR8305 3/4" Pilot Valve Honeywell VR8205
Firing Valve Honeywell B200T1025 3/4" Air Switch Cleveland RSS-495
Ignition Control UTC 1003-61A Blower Motor 1/5 hp - FLA 3.0
Operating Control Tekmar BTC-2PA Relief Valve - DW 3/4" x 3/4" set @ 125 psi
High Limit Honeywell L4008E Relief Valve - DB 3/4" x 3/4" set @ 50 psi
Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 50.0 Sq. Ft. / 4.65 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 3.6 gal / 13.6 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP15°F / 8.3°C 20°F / 11.1°C 25°F / 13.9°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
45.3 2.9 0.49 1.5 34.0 2.1 0.29 0.9 27.2 1.7 0.19 0.6
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-400-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
1018 3853 679 2569 509 1927 407 1541 339 1284 291 1101
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
Dominator 400 model water heater not available for sale in the U.S. market due to DOE regulations.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 600Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-600-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-29-D
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
5 in [12.6 cm]
29 5/16 in [74.4 cm]
17 9/16 in [44.6 cm]
35 1/8 in [89.2 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
7 in [17.8 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
40 3/16 in [102.1 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
17 1/4 in [43.9 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
4 7/8 in [12.4 cm]
5 in [12.6 cm]
29 5/16 in [74.4 cm]
17 9/16 in [44.6 cm]
35 1/8 in [89.2 cm]
4 7/16 in [11.3 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
7 in [17.8 cm]
33 1/16 in [84.0 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE
40 3/16 in [102.1 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
17 1/4 in [43.9 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 600Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 3.8*
Input BTU/hr. 600,000 / 176 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 510,000 / 149 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 532 lbs. / 242 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1" Blower Motor 1/5 hp - FLA 3.0
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 3/4" set @ 50 psi
High Limit Honeywell L4008E Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 64.0 Sq. Ft. / 5.95 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 3.8 gal / 14.5 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP15°F / 8.3°C 20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
68.0 4.3 1.30 3.8 51.0 3.2 0.76 2.2 40.8 2.6 0.50 1.5 34.0 2.1 0.36 1.1
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-600-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
1486 5616 990 3744 743 2808 594 2246 495 1872 424 1604
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 750Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-750-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-30-D
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
Ø2 1/2" WATER(2 PLCS.)
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"[20.32 cm]
4 7/16 in [11.3 cm]
41 5/8 in [105.7 cm]
20 13/16 in [52.9 cm]
5 3/16 in [13.2 cm]
8 in [20.3 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
6 1/4 in [15.9 cm]
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.5 cm]
5 in [12.7 cm]
15 15/16 in [40.5 cm]
11 in [28.0 cm]
46 11/16 in [118.7 cm]
35 3/16 in [89.4 cm] 31 7/8 in
[80.9 cm]
2 3/4 in [7.0 cm]
19 in [48.3 cm]
12 15/16 in [32.9 cm]
20 5/16 in [51.5 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
Ø2 1/2" WATER(2 PLCS.)
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø8"[20.32 cm]
4 7/16 in [11.3 cm]
41 5/8 in [105.7 cm]
20 13/16 in [52.9 cm]
5 3/16 in [13.2 cm]
8 in [20.3 cm] REAR FLUE OUTLET
(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
6 1/4 in [15.9 cm]
Ø1"NAT & LP
29 5/16 in [74.4 cm]
37 7/8 in [96.1 cm]
26 9/16 in [67.5 cm]
5 in [12.7 cm]
15 15/16 in [40.5 cm]
11 in [28.0 cm]
46 11/16 in [118.7 cm]
35 3/16 in [89.4 cm] 31 7/8 in
[80.9 cm]
2 3/4 in [7.0 cm]
19 in [48.3 cm]
12 15/16 in [32.9 cm]
20 5/16 in [51.5 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 750Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 5.9*
Input BTU/hr. 750,000 / 220 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 637,500 / 187 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 573 lbs. / 260 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1" Blower Motor 1/4 hp - FLA 5.1
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 3/4" set @ 50 psi
High Limit Honeywell L4008E Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 77.0 Sq. Ft. / 7.15 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 3.9 gal / 14.9 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
63.8 4.0 1.38 4.1 51.0 3.2 0.91 2.7 42.5 2.7 0.65 1.9 36.4 2.3 0.49 1.4
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-750-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
1857 7019 1238 4680 928 3510 743 2808 619 2340 531 2006
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 900Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-900-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-31-D
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
6 5/16 in [16.1 cm]
29 5/16 in [74.4 cm]
24 1/16 in [61.1 cm]
48 1/8 in [122.2 cm]
6 7/16 in [16.4 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
10 in [25.4 cm]
31 5/8 in [80.3 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
53 3/16 in [135.2 cm] 18 15/16 in
[48.1 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
19 1/16 in [48.4 cm]
23 5/8 in [60.1 cm]
12 15/16 in [32.9 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
6 5/16 in [16.1 cm]
29 5/16 in [74.4 cm]
24 1/16 in [61.1 cm]
48 1/8 in [122.2 cm]
6 7/16 in [16.4 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1"NAT & LP
10 in [25.4 cm]
31 5/8 in [80.3 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
53 3/16 in [135.2 cm] 18 15/16 in
[48.1 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
19 1/16 in [48.4 cm]
23 5/8 in [60.1 cm]
12 15/16 in [32.9 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 900Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 5.9*
Input BTU/hr. 900,000 / 264 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 765,000 / 224 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 664 lbs. / 301 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1" Blower Motor 1/4 hp - FLA 5.1
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 3/4" set @ 50 psi
High Limit Honeywell L4008E Flow Switch TACO
A.S.M.E.ASME Sect IV Htg Surface 90.0 Sq. Ft. / 8.36 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 4.1 gal / 15.4 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
76.5 4.8 2.25 6.6 61.2 3.9 1.49 4.4 51.0 3.2 1.06 3.1 43.7 2.8 0.80 2.4
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-900-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
2228 8423 1486 5616 1114 4212 891 3369 743 2808 637 2407
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 1050Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-1050-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-32-D
15 3/8 in [39.1 cm]
15 in [38.1 cm]
3 13/16 in [9.7 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
6 5/16 in [16.1 cm]
29 5/16 in [74.4 cm]
29 3/16 in [74.1 cm]
58 3/8 in [148.3 cm]
4 3/16 in [10.7 cm]
8 7/8 in [22.5 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
10 in [25.4 cm]
31 5/8 in [80.3 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
63 7/16 in [161.2 cm]
20 7/8 in [53.1 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
28 11/16 in [72.9 cm]
19 1/16 in [48.4 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
3 13/16 in [9.7 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
6 5/16 in [16.1 cm]
29 5/16 in [74.4 cm]
29 3/16 in [74.1 cm]
58 3/8 in [148.3 cm]
4 3/16 in [10.7 cm]
8 7/8 in [22.5 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
Ø10"
5 3/16 in [13.2 cm]
Ø2 1/2" WATER(2 PLCS.)
Ø1 1/4"NAT & LP
10 in [25.4 cm]
31 5/8 in [80.3 cm]
REAR FLUE OUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
63 7/16 in [161.2 cm]
20 7/8 in [53.1 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
28 11/16 in [72.9 cm]
19 1/16 in [48.4 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 1050Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,050,000 / 308 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 892,500 / 262 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 772 lbs. / 350 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell (2) V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell (2) B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1-1/4" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 3/4" set @ 50 psi
Operating Control Tekmar BTC-4PA Flow Switch TACO
High Limit Honeywell L4008E
A.S.M.E.ASME Sect IV Htg Surface 110.0 Sq. Ft. / 10.22 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 4.4 gal / 16.8 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
89.3 5.6 3.65 10.7 71.4 4.5 2.41 7.1 59.5 3.8 1.72 5.1 51.0 3.2 1.29 3.8
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-1050-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
2597 9815 1731 6544 1298 4908 1039 3926 866 3272 742 2804
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 1350Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-1350-7The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-33-E
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
35 11/16 in [90.6 cm]
71 3/8 in [181.3 cm]
4 3/16 in [10.7 cm]
13 3/8 in [34.0 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
Ø1 1/4"NAT & LP Ø12"
12 in [30.5 cm]
30 in [76.3 cm]
AIR INTAKE(REAR MOUNTOPTIONAL)
27 3/8 in [69.6 cm]
11 in [28.0 cm]
76 7/16 in [194.2 cm]
35 3/16 in [89.4 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
35 13/16 in [91.0 cm]
CENTER OFGRAVITY
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
35 11/16 in [90.6 cm]
71 3/8 in [181.3 cm]
4 3/16 in [10.7 cm]
13 3/8 in [34.0 cm]
29 5/8 in [75.2 cm]
7 1/2 in [19.1 cm]
2 3/4 in [7.0 cm]
5 3/16 in [13.2 cm]
Ø1 1/4"NAT & LP Ø12"
12 in [30.5 cm]
30 in [76.3 cm]
AIR INTAKE(REAR MOUNTOPTIONAL)
27 3/8 in [69.6 cm]
11 in [28.0 cm]
76 7/16 in [194.2 cm]
35 3/16 in [89.4 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
35 13/16 in [91.0 cm]
CENTER OFGRAVITY
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 1350Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,350,000 / 396 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,147,500 / 336 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 805 lbs. / 365 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell (2) V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell (2) B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1-1/4" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 1" set @ 50 psi
Operating Control Tekmar BTC-4PA Flow Switch TACO
High Limit Honeywell L4008E
A.S.M.E.ASME Sect IV Htg Surface 136.0 Sq. Ft. / 12.63 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 4.8 gal / 18.2 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP20°F / 11.1°C 25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
114.8† 7.2† 7.15 21.1 91.8 5.8 4.73 13.9 76.5 4.8 3.38 9.9 65.6 4.1 2.54 7.5
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
SDOM-1350-7
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
3339 12620 2226 8413 1669 6310 1335 5048 1113 4207 954 3606
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 1500Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-1500-8The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-34-F
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 1500Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,500,000 / 440 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,275,000 / 374 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 846 lbs. / 384 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell (2) V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell (2) B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1-1/4" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 1" set @ 50 psi
Operating Control Tekmar BTC-4PA Flow Switch TACO
High Limit Honeywell L4008E
A.S.M.E.ASME Sect IV Htg Surface 149.0 Sq. Ft. / 13.84 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 4.9 gal / 18.6 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP25°F / 13.9°C 30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa GPM L/s Ft kPa
102.0 6.4 6.29 18.5 85.0 5.4 4.49 13.2 72.9 4.6 3.37 9.9
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-1500-8
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
3709 14022 2473 9348 1855 7011 1484 5609 1236 4674 1060 4006
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 1950Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-1950-8The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-35-F
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
48 11/16 in [123.7 cm]
97 3/8 in [247.3 cm]
4 3/16 in [10.7 cm]
26 3/8 in [67.0 cm]
5 3/16 in [13.2 cm]
Ø2"NAT & LP
Ø2 1/2" WATER(2 PLCS.)
Ø12"
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
30 in [76.3 cm]
REAR FLUEOUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
102 7/16 in [260.3 cm]
40 3/8 in [102.6 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
14 in [35.6 cm]41 11/16 in
[105.9 cm]
2 3/4 in [7.0 cm]
47 7/8 in [47.9 cm]
19 1/16 in [19.1 cm]
12 15/16 in [12.9 cm]
50 9/32 in [50.3 cm]
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
48 11/16 in [123.7 cm]
97 3/8 in [247.3 cm]
4 3/16 in [10.7 cm]
26 3/8 in [67.0 cm]
5 3/16 in [13.2 cm]
Ø2"NAT & LP
Ø2 1/2" WATER(2 PLCS.)
Ø12"
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
30 in [76.3 cm]
REAR FLUEOUTLET(OPTIONAL)
AIR INTAKE(REAR MOUNTOPTIONAL)
102 7/16 in [260.3 cm]
40 3/8 in [102.6 cm]
11 in [28.0 cm]
35 3/16 in [89.4 cm]
14 in [35.6 cm]41 11/16 in
[105.9 cm]
2 3/4 in [7.0 cm]
47 7/8 in [47.9 cm]
19 1/16 in [19.1 cm]
12 15/16 in [12.9 cm]
50 9/32 in [50.3 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 1950Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 1,950,000 / 572 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,657,500 / 486 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 1088 lbs. / 494 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell (2) V8944 1" Pilot Valve Honeywell VR8205
Firing Valve Honeywell (2) B200T1033 1" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1-1/2" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 1-1/4" set @ 50 psi
Operating Control Tekmar BTC-4PA Flow Switch TACO
High Limit Honeywell L4008E
A.S.M.E.ASME Sect IV Htg Surface 189.0 Sq. Ft. / 17.56 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 5.4 gal / 20.4 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
110.5† 7.0† 9.18 27.0 94.7 6.0 6.90 20.3
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-1950-8
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
4816 18206 3211 12138 2408 9103 1927 7283 1605 6069 1376 5202
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.
CODE OPTIONS
CSD-1UTC Lockout/Reset Control Manual Reset LWCO
Notes: 1. Dimensions are approximate and should not be used to "rough-in" equipment.2. Dimensions are subject to change without notice.
DOMINATOR 2100Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
SDOM-2100-8The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
RSUB-36-F
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
51 15/16 in [131.9 cm]
103 7/8 in [263.8 cm]
4 3/16 in [10.7 cm]
29 7/8 in [75.9 cm]
5 3/16 in [13.2 cm]
Ø2"NAT & LP
Ø2 1/2" WATER(2 PLCS.)
Ø12"
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
REAR FLUEOUTLET(OPTIONAL)
30 in [76.3 cm]
AIR INTAKE(REAR MOUNTOPTIONAL)
43 5/8 in [110.9 cm]
11 in [28.0 cm]
108 15/16 in [276.8 cm]
35 3/16 in [89.4 cm]
14 in [35.6 cm]
44 15/16 in [114.1 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
51 1/16 in [129.7 cm]
15 3/8 in [39.1 cm]
15 in [38.1 cm]
4 1/4 in [10.8 cm]
26 9/16 in [67.5 cm]
37 7/8 in [96.2 cm]
5 in [12.6 cm]
7 13/16 in [19.8 cm]
29 5/16 in [74.4 cm]
51 15/16 in [131.9 cm]
103 7/8 in [263.8 cm]
4 3/16 in [10.7 cm]
29 7/8 in [75.9 cm]
5 3/16 in [13.2 cm]
Ø2"NAT & LP
Ø2 1/2" WATER(2 PLCS.)
Ø12"
7 1/2 in [19.1 cm]
29 5/8 in [75.2 cm]
REAR FLUEOUTLET(OPTIONAL)
30 in [76.3 cm]
AIR INTAKE(REAR MOUNTOPTIONAL)
43 5/8 in [110.9 cm]
11 in [28.0 cm]
108 15/16 in [276.8 cm]
35 3/16 in [89.4 cm]
14 in [35.6 cm]
44 15/16 in [114.1 cm]
2 3/4 in [7.0 cm]
12 15/16 in [32.9 cm]
19 1/16 in [48.4 cm]
51 1/16 in [129.7 cm]
REP FIRM
SUBMITTED BY
JOB NAME
ARCHITECT
ENGINEER
CONTRACTOR
DATE
DOMINATOR 2100Category I or Category III Appliance
(see Installation and Operation Manual for venting information)
A Division of Mestek, Inc.Westfield, MA 01085(413) 564-5515
BOILER CERTIFIED RATINGS & CAPACITIESFuel Type Natural/Propane Gas Boiler FLA 11.0*
Input BTU/hr. 2,100,000 / 616 kW Min. Gas Pressure Required 7" WC**
Output BTU/hr. 1,785,000 / 523 kW Max. Gas Pressure Allowed 14" WC
Electrical Requirements 120VAC/ 1 ph/ 60 hz Operating Weight 1105 lbs. / 502 kg.
BOILER / WATER HEATER TRIM & CONTROLSMain Gas Valve Honeywell (2) V8944 1-1/4" Pilot Valve Honeywell VR8205
Firing Valve Honeywell (2) B200T1041 1-1/4" Air Switch Cleveland RSS-495
Safety Valve ASCO L8214G 1-1/2" Blower Motor (2) 1/4 hp - FLA 10.2
Ignition Control UTC 1003-61A Relief Valve - DW 3/4" x 3/4" set @ 125 psi
Operating Control Tekmar BTC-2PA Relief Valve - DB 3/4" x 1-1/4" set @ 50 psi
Operating Control Tekmar BTC-4PA Flow Switch TACO
High Limit Honeywell L4008E
A.S.M.E.ASME Sect IV Htg Surface 202.0 Sq. Ft. / 18.77 Sq. M. Design Data Max. 160 psig & 250˚F
Water Volume 5.6 gal / 21.4 Liters
BOILER TEMPERATURE RISE / PRESSURE DROP30°F / 16.7°C 35°F / 19.4°C
Flow Rate Pressure Drop Flow Rate Pressure Drop
GPM L/s Ft kPa GPM L/s Ft kPa
119.0† 7.5† 11.24 33.1 102.0 6.4 8.45 24.9
* Add circulator amps.** For incoming gas pressures lower than 7” WC natural or 11” WC propane, consult factory.
SDOM-2100-8
WATER HEATER HOURLY RECOVERY CAPACITY (GPH & LPH)40°F 22°C 60°F 33°C 80°F 44°C 100°F 56°C 120°F 67°C 140°F 78°C
5187 19607 3458 13071 2593 9803 2075 7843 1729 6536 1482 5602
The Dominator Boiler Series will no longer be available for sale in the Canadian Province of Ontario due to the Ontario Regulation 404/12, Green Energy Act 2009.
† Flow exceeds recommended maximum use a greater temperature rise or consult manufacturer. Cupronickel heat exchanger should be considered.