Documento 150612033923

download Documento 150612033923

of 16

description

fluke

Transcript of Documento 150612033923

  • PHILIPS

    Fabio Alberto Castro FonsecaEngineering Development and IntegrationSCM Andean ClusterPhilips Colombiana S.A.S Calle 93 No 11 A-11 Piso 7. Tel 4222600PBX: +57 1 422 2600, Fax: +57 1 422 2670Email: [email protected]

    Prueba Trmica Housing ColorBurst

    Termografa

  • Prepared for:

    Nicolas GonzlezNicols Gonzlez DuarteApplication SpecialistS+SCC, Profesional Lighting SolutionsPhilips Colombiana S.A.S. Calle 93 No. 11A - 11 Piso 7 - Bogot, Colombia.Tel: +57 1 422 2600Mobile: +57 310 248 8671Email: [email protected]

    2

  • Table Of Contents

    IR000001.IS2 5

    IR000002.IS2 7

    IR000003.IS2 9

    IR000004.IS2 11

    IR000005.IS2 13

    IR000006.IS2 15

    3

  • Inspection SummaryFile name IR000001.IS2 Inspection Date

    and Time09-May-11 1:59:43 AM

    Severity NoneFile name IR000002.IS2 Inspection Date

    and Time09-May-11 2:00:04 AM

    Severity NoneFile name IR000003.IS2 Inspection Date

    and Time09-May-11 2:01:37 AM

    Severity NoneFile name IR000004.IS2 Inspection Date

    and Time09-May-11 2:02:21 AM

    Severity NoneFile name IR000005.IS2 Inspection Date

    and Time09-May-11 2:35:17 AM

    Severity NoneFile name IR000006.IS2 Inspection Date

    and Time09-May-11 2:35:56 AM

    Severity None

    4

  • Inspected By:

    Inspection Date: 09-May-11 1:59:43 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000001.IS2 Visible Light Image

    Graph

    5

  • Image InfoTransmission 1.00Average Temperature 34.23CImage Range 27.96C to 59.31CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 1:59:43 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000001.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 48.54C 33.91

    C59.31

    C0.85 23.90C 4.32

    Name Temperature Emissivity BackgroundPunto central 45.05C 0.85 23.90C

    Caliente 59.31C 0.85 23.90C

    6

  • Inspected By:

    Inspection Date: 09-May-11 2:00:04 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000002.IS2 Visible Light Image

    Graph

    7

  • Image InfoTransmission 1.00Average Temperature 34.59CImage Range 28.55C to 58.91CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 2:00:04 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000002.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 47.96C 32.80

    C58.91

    C0.85 23.90C 4.65

    Name Temperature Emissivity BackgroundPunto central 44.38C 0.85 23.90C

    Caliente 58.91C 0.85 23.90CP0 52.66C 0.85 23.90C

    8

  • Inspected By:

    Inspection Date: 09-May-11 2:01:37 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000003.IS2 Visible Light Image

    Graph

    9

  • Image InfoTransmission 1.00Average Temperature 32.99CImage Range 27.32C to 58.63CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 2:01:37 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000003.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 38.66C 30.44

    C47.01

    C0.85 23.90C 1.21

    Name Temperature Emissivity BackgroundPunto central 38.32C 0.85 23.90C

    P0 47.01C 0.85 23.90C

    10

  • Inspected By:

    Inspection Date: 09-May-11 2:02:21 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000004.IS2 Visible Light Image

    Graph

    11

  • Image InfoTransmission 1.00Average Temperature 32.61CImage Range 27.16C to 57.90CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 2:02:21 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000004.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 38.32C 30.13

    C46.79

    C0.85 23.90C 1.24

    Name Temperature Emissivity BackgroundPunto central 37.94C 0.85 23.90C

    P0 46.79C 0.85 23.90C

    12

  • Inspected By:

    Inspection Date: 09-May-11 2:35:17 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000005.IS2 Visible Light Image

    Graph

    13

  • Image InfoTransmission 1.00Average Temperature 49.78CImage Range 33.96C to 64.15CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 2:35:17 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000005.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 59.16C 53.04

    C64.15

    C0.85 23.90C 2.55

    Name Temperature Emissivity BackgroundPunto central 60.26C 0.85 23.90C

    Caliente 64.15C 0.85 23.90C

    14

  • Inspected By:

    Inspection Date: 09-May-11 2:35:56 AM AreaLocation CompassDescription Weather Conditions:Indoor Air Temperature Outdoor Air

    TemperatureIndoor Relative Humidity:

    Outdoor Relative Humidity:

    Dew Point (inside): Wind SpeedProblem Repair Priority:Emissivity: 0.85 Reflected

    Temperature:23.90 C

    Camera Manufacturer Fluke Thermography Camera: Ti32-11120003 (9Hz)

    IR000006.IS2 Visible Light Image

    20150611_114935.JPG

    15

  • Graph

    Image InfoTransmission 1.00Average Temperature 38.31CImage Range 28.21C to 65.35CCamera Model Fluke Ti32IR Sensor Size 320 x 240DSP Version 1.2.14OCA Version 1.2.14Image Time 09-May-11 2:35:56 AMFile Location C:\ Users\ coc00550\ Desktop\ Housing

    ColorBurst\ TI_00000\ IR000006.IS2Calibration Range -10.00C to 600.00CSeverity None

    Main Image MarkersName Avg Min Max Emissivity Background St.

    Dev.A0 58.78C 50.61

    C64.39

    C0.85 23.90C 2.20

    A1 55.49C 41.46C

    65.35C

    0.85 23.90C 4.16

    Name Temperature Emissivity BackgroundPunto central 52.64C 0.85 23.90C

    Caliente 65.35C 0.85 23.90CPunto de Medicin 53.89C 0.85 23.90C

    16